Loading...
HomeMy WebLinkAbout45928-Z �o�g�FF01k�oGy Town of Southold 5/18/2021 P.O.Box 1179 o _ �; 53095 Main Rd 4 �ao�.2 Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 42033 Date: 5/18/2021 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1450 Wickham Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 139.-3-47 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/26/2021 pursuant to which Building Permit No. 45928 dated 3/15/2021 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as applied for. The certificate is issued to DeFio,Valerie&Bruce of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45928 5/3/2021 PLUMBERS CERTIFICATION DATED Authorize ignature Fal. ' TOWN OF SOUTHOLD �� oy BUILDING DEPARTMENT x TOWN CLERK'S OFFICE SOUTHOLD, NY ' .zsrs% BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45928 Date: 3/15/2021 Permission is hereby granted to: DeFio, Valerie 1450 Wickham Ave Mattituck, NY 11952 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 1450 Wickham Ave, Mattituck SCTM #473889 Sec/Block/Lot# 139.-3-47 Pursuant to application dated 2/26/2021 and approved by the Building Inspector. To expire on 9/14/2022. Fees: SOLAR PANELS $50.00 CO-ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 Total: $200.00 Buil ing c or Form No.6 TOWN OF SOUTROLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. New Construction: Old or Pre-existing Building: X (check one) Location of Property: 1450 Wickham /Avenue Mattituck House No. Street Hamlet Owner or Owners of Property: Bruce DeFiO Suffolk County Tax Map No 1000,Section 139 Block 3 Lot 47 Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ 50.00 Applicant Signature Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) I, Bruce Defio residing at 1450 Wickham Ave, Mattituck, NY 11952 (Print property owner's name) (Mailing Address) do hereby authorize Scott Maskin-SUNation Solar Systems (Agent) to apply on my behalf to the Southold Building Department. /2 ?tel 0;n'er's Signature) (Date) (Print Owner's Name) pF SOUry®� Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 ® �®� sean.devlinatown.Southold.ny.us lyCOUM`I,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Valerie DeFio Address: 1450 Wickham Ave city.Mattituck st: NY zip: 11952 Building Permit#: 45928 Section- 139 Block 3 Lot 47 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: SUNation License No: 33412ME SITE DETAILS Office Use Only Residential X Indoor X Basement Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceding Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment 9.36kW Roof Mounted PV Solar Energy System w/ (26) REC 360AA Panels, Enphase IQ-3 Combiner w/230x3 210x1 and 260 Disconnect Notes: Solar Inspector Signature: �� Date: May 3, 2021 S Devlin-Cert Electrical Compliance Form As o�aOF SOUIyO L-t At i * * TOWN OF SOUTHOLD� BUILDING DEPT: °`�courm ' 765-1802 . A NSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION _ [ ]- FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: > TAX 0&�W& h*e�Az im a DATE :� T Z( _ - INSPECTOR Fisher Engineering Services, P.C. 509 Sayville Blvd • Sayville-New York 11782 Phone: (631) 786-4419 April 29, 2021 Town of Southold Building Department Post Installation Certification Subject: Engineer Statement for Solar Roof Installation Residence- Defio— 1450 Wickham Avenue, Mattituck Permit No. 45928 Installation Inspection Date: 4/16/2021 The roof mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the approved plans and is certified by Fisher Engineering Services,P.C..to be in compliance with the minimum requirements of the Town,the 2020 Residential Code of New York State, 2018 International Residential Code(2018 IRC), Long Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code 2017,and the provisions of ASCE'7-15. NEpy - - t Sincerely, �. William G.Fisher, P.E. Licensed Professional Engineer Architectural Design-Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight-Expediting•Inspections FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(1ST) N "" C 'FOUNDATION(2ND) • �o C ROUGH FRAMING& �' w PLUMBINGy 1 INSULATION PER N.Y: STATE ENERGY CODE FINAL ADDITIONAL COMMENTS r b L rn P N ~ z �1 2266 22 1 TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX:(631)765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. Check Septic Form N.Y.S.D.E C. Trustees C.O.Application Flood Permit Examined 3115 ,20 Single&Separate Stonn-Water Assessment Form Contact: Approved 15,20 Marl to-SUNahon Solar Systems,Inc Disapproved a/c 171 Remington Boulevard,Ronkonkoma NY 11779 TTI f Phone:(631)750-9454 Expiration I ,20 Buildtng Inspector APPLICATION FOR BUILDING PERMIT Date ,20 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. P c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and re ' s,and to admit authorized inspectors on premises and in building for necessary inspections. gnature of applicant or name,if a corporation) SUNahon Solar Systems,Inc 171 Remington Boulevard,Ronkonkoma NY 11779 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder SUNahon Solar Systems,Inc-Contractor Name of owner of premises Bruce DeFio (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer Scott Maskm-President (Name and title of corporate officer) Builders License No.44104-H 'Plumbers License No. N/A Electricians License No.33412-ME Other Trade's License No. 1. Location of land on which proposed work will be done: 1450 Wickham Avenue Mattituck House Number Street Hamlet County Tax Map No. 1000 Section 139 Block 3 Lot 47 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Residence b. Intended use and occupancy Residence with addition of solar Panus 3. Nature of work(check which applicable):New Building AdditionEl Alteration[_ Repair Removal Demolition Other Work solarla 6 (Description) 4. Estimated Cost $30,078 Fee $200 00 (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law,ordinance or regulation?YES_NO X 13. Will lot be re-graded?YES_NO X Will excess fill be removed from premises?YES_NO X 14. Names of Owner of premises Bruce DeFlo Address 1450 Wickham Av,Mathtuck,NV 11952 Phone No. 631-487-9835 Name of Architect wdliam c Elsner Address PO Box 30,Oakdale,NV 11769 Phone No 631-7664419 Name of Contractor sUNahoh solar systems,Inc Address 171 R.--ion Boulevard,Ronkonkoma NYPhone No. 631-750-9454 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO X *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland?*YES NO X *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO X *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OFf,) Scott Maskin-President-SUNation Solar Systems,Inc. being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this a k day of n� 20 c) I Nota Public Signature of Applicant TAMMY LEA Notary Public,State of New Yah Registration No.01LE6410842 Qualified In Suffolk County Commission Expires November 2,20A N Scott A. Russell ��� STOIEZMNWA IFIER SUPERVISOR 0r MA- A G IEMIENT SOUTHOLD TOWN HALL.-P.O.Box 1179 51095 Main Road-SOL7HOLD,NEW YOM< 11971 � 'own of Southold C EIS 236 - STORMWATER NIANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) iO TMS PROJECT INVOLVE ANY OF THE FOLLOWING. Yes No (CHECK ALL THAT APPLY) A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ® B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ® D. Site preparation within 100 feet of wetlands, beach, bluff or coastal I` erosion hazard area. (� E. Site preparation within the ane-hundred-year f loodplain as depicted on FIRM Map of any watercourse. Op F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes In-kind replacement of impervious surfaces. If you answered NO to all of the Questions above,STOP! Complete the Applicant section below with your Dame, Signature,Contact Information,Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above,please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICAWa (Property Owner,Resign ProfeasionaL agent.Contractor.Other) S.C.T.'VI. IOODistric Date ct NAN* Scott Mas • Nation Solar Systems 139 3 47 an Section Bioci. -Lot- 5�,, ,.> "FOR BUILDING DEPARTMENT USE ONLY Contact Informatim. Tammy Lea/ 631-750-9454 eTekgparc Aacbr Reviewed By: Bate: Property Address I Location of Construction Work: — — — -- — — — — — — — — — — — — — 1450 Wickham Avenue Approved for processing Building Permit. Stoi rn ater Management Control Plan Not Required. Mattituek, NY 11952 — Stormwater Management Control Plan is Required 0 (Forward to Engineering Department for Review.) - -- ---- -- ---- --- - -------- --------------------- - -------------- ----------------- ---- --- -- -- F4RlA SiVtCP-TOS NIAY 2QIA IS BUILDING DEPARTMENT- Electrical Inspector �y TOWN OF SOUTHOLD C:11 Town Hall Annex - 54375 Main Road - PO Box 1179 a' ® Southold, New York 11971-0959 ���', Telephone (631) 765-1802 - FAX (631) 765-9502 Q� ' �` ' rogerrCa)southoldtownny.gov seanda-southoldtownny-gov 'APP.LI,GATION FOR ELECTRICAL INSPECTION- ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: Name: -- License No.: v email: ' �1p Address: - 1A -- - Phone No.: JOB SITE INFORMATION (All Information Required) Name:____ Bruce_DeFio___ Address: 1450,Wickham Avenue,Mattituck,_NY 11952 Cross Street: Phone No.: 631-487-9835 Bldg.Permit#: 7i email: .Tax Map_District:. 1000- _- Section: 139 _Block: 3 _ Lot 47 BRIEF DESCRIPTION OF WORK (Please Print Clearly) 9360W Roof Mounted Solar Photovoltaic System Including: 26-REC Solar REC360AA Black and 26-Enphase IQ7PIus-72-2-US Microinverters .-_ Circle All That Apply: Is job ready for inspection?: YES / NO Rough In ' Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: _ _A # Meters Old Meter#, _. ____ _ New Service- Fire Reconnect- Flood Reconnect-Service Reconnected- Underground - Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Forrn.xls PERMIT# Address: Switches Outlets ` GFI's Surface Sconces H H's UC Lts - Fans - Fridge HW.,. -- _, t . Exhaust Oven Dryer Smokes _.. DW_' Service Carbon ___ . _. Micro. { ✓ - f ¢ Combo _.tsV,_. Cdoktop `.". -Transfer,- AC Transfer AC _. . _.• AH „ ; _ ;5 ,r . Mini- Special: ini' Special_• Comments 1 _ } , ,- _ mit' ••I^ - ,` _ -, '• ,- ,.f -• - „ `'+ `' .'� ,r a Q NYSIF199 CHURCH STREET,NEW YORK,N.Y.10007-1100 New.York State Insurance-Fund nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE "A A A A 753118816 01 NO GCG RISK MANAGEMENT INC 100 CHURCH STREET-SUITE 810 NEW YORK NY 10007 � SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBERPOLICY PERIOD DATE Z 2160 670-2 914289 01/01/2021 TO 01/01/2022 12/15/2020 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP. THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER: 97111331 IIUIIIIIIIIIIIIl000l01000110000�08186571101I�IIIIIIIIIIIII Forth WC-CERT-NOPRINT Version 3(08/29/2019)[WC Policy-21606702] U-26 3 r7 rm­n ...o<e,u mann.mnm.en<,n„rn..,,n r<,„nrr_i u_n root nm.mon., RECEIPT SUFFOLK COUNTY GOVERNMENT DEPARTMENT OF LABOR, LICENSING,AND CONSUMER AFFAIRS ACTING COMMISSIONER ROSALIE DRAGO P.O. BOX 6100, HAUPPAUGE, NY 11788 _(631) 853 4600 Today Date: 02/25/2020 Application: H-44104 Application Type: Home Improvement License Receipt No. 402742 Payment Method Ref. Number Amount Paid Payment Date Cashier ID Comments Check 31300 $400.00 02/25/2020 GAB Renewal Contact Info: SUNATION SOLAR SYSTEMS INC SCOTT A MASKIN 171 REMINGTON BLVD. , RONKONKOMA, NY 11779 Work Description - Suffolk County Dept.of Labor,Licensing&consumer Affairs j HOME IMPROVEMENT LICENSE i i Name SCOTT A MASKIN #{ Business Name This certirtes that the SUNATION SOLAR SYSTEMS INC bearer is duty Itcensed f by the county of sutfolk V License Number: H-44104 I Rosalie orago Issued: 03/06/2008 Acting Commissioner Expires: 03/01/2022 Show Receipt Detail Page 1 of 2 RECEIPT Suffolk County Government SUFFOLK COUNTY LABOR, LICENSING& CONSUMER AFFAIRS P.O. BOX 6100 HAUPPAUGE, NY 11788 James M. Andrews Application:ME-33412 Application Type:ConsumerAffairs/Licenses/Master Electrician/NA Address: Owner Name:SUNATION SOLAR SYSTEMS INC Owner Address:171 REMINGTON BLVD RONKONKOMA,NY 11779 Application Name: Receipt No. 160594 Payment Method Ref Number Amount Paid Payment Date Cashier ID Received Comments Check 27486 $400.00 06/04/2019 CLEMON RENEWAL Owner Info: SUNATION SOLAR SYSTEMS INC 171 REMINGTON BLVD RONKONKOMA, NY 11779 Work Description: Suffolk County Dept.of 1t Labor,Licensing&Consumer Affairs MASTER ELECTRICAL LICENSE 4 Name 1 ,• '. '' SCOTT A MASKIN Business Name This certifies that the SLINATION SOLAR SYSTEMS INC bearer is duly licensed I by the County of suffoik i License Number:ME-33412 Fra*%k,Nard ()Ii, issued: 06/2412003 Commissioner Expires: 06101/2021 hone•//avnrnrl c,iffnllmni,ntvnv nnv/nnrtlets/fee/receintView.do?mode=view&autoPrint=fals... 6/4/2019 C AP I IED AS NOTED DATE:3 5 B.P.# s L�D FEE: Rv _ NOTIFY BUILDING 'APARTMENT AT 765-1802 8 AM TO 4 Pkil FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CCNCRETE 2. ROUGH - FRAMING PLUMBING 3. INSULATION 4. FINAL - CONSTF. -,N MUST BE COMPLETE - ,0, ALL CONSTRUCTICrti :-ALL MEET THE REQUIREMENTS OF THE CODES OF NEW �L�OTRf�A� YORK STATE. NOT RESPONSIBLE FOR INSPECTION REQUIRED DESIGN'OR CONSTRUCTION ERRORS, _�- COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF �EbfiNBLf�TB _ SOJDQLD TOWNTOWN PL =BOARD -SOUTHOO TOWN TEES N.Y.S.DEC OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICA7 OF OCCUPANCY 1 1 , •5ii REC'�ALP'H,.(X � B:L K '. ,-t5- ,,ERI El� �S !ti t 1 1f��r' •� QMon m0 1721±2.5[67 75±0 1] 28[1.1] 80201.51 455[17.9] CERTIFICATIONS a _ IEC 6121S2016,IEC 617302016__,UL_170.3,UL61730 ❑ �� ° + IEC 62804 PID 1000[39] IEC 61701 Salt Mist IEC 62716 Ammonia Resistance ISO 11925-2 Ignitability(Class E) IEC 62782 Dynamic Mechanical Load +I IEC 61215-2 2016 — Hailstone(35mm) —_ +I M AS4040 2 NCC 2016 Cyclic Wind Load N' N ® ISO140012004,ISO 90012015,OHSAS 180012007,IEC 62941 +I o f o 11±0+ v ® C E ❑ take Awa P r o'[0.43—0 8] ^ B fi • takes-wa WEEE-�m pant I � C US reryctmgsrheme I n �%WARRANTY* 20 5±0 5 V _.—__.va.,_ [0.78±0.08] 1200[47] — Standard REC ProTrust Installed by an REC Certified No Yes Yes T Solar Professional 621±3[24 5±012] System Size All E25 kW 25-500 kW —��-45[15] 225[09] _—___� -- Product Warranty(yrs) 20 25 25 I30[1.18] — - —-- - ------ --------— Power Warranty(yrs) 25 25 25 Measurements in mm[in] Labor Warranty(yrs) 0 25 10 GENERAL DATA Power in Year 1 98% 98% 98% 120half-cutcells with REC StaubllMC4PV-KBT4/KST4(4mm2) Annual Degradation — —025_% 025% 025% Celltype heterojunction cell technology Connectors inaccordancewtthIEC 62852 Power in Year 25 92% 92% 92% 6 strings of 20 cells in series IP68 onlywhen connected See warranty documents for details Condttionsapply 3 2 mm solarglass with 4 mm2 solarcable,l O m+1.2 m Glass Cable MAXIMUM RATINGS antrreflecttonsurface treatment maccordancewrthEN50618 ��_ _ Highly resistant Operational temperature' -40 +85°C Backsheet Dimensions 1721 x 1016 x30 mm(175 ml)polymeric construction(black) Maximum system voltage 1000V Frame Anodized aluminum(black) Weight 19 5 kg Design load(+) snow 4666 Pa(475 kg/m2)' Maximum test load(+) 7000 Pa(713 kg/mz)* 3-part,3 bypass diodes,IP67 rated Junctionbox in accordance with IEC 62790 Origin Made in Singapore Design load(-)wind 2666Pa(272kg/m2)' Maximum test load() 4000 Pa(407 kg/m2)* y ELECTRICAL -_ T Product Code:"RECx_xxAABlack —_ Max series fuse rating- 25A Power Output PMAx(Wp) 3SS =360 36S 370 375 Max reverse current 25A r Watt Class Sorting-(W) -0/+5 0/+5 0/+5 0/+5 -0/+5 Calculated using a safety factor ofl5 See installation manual for mounting instructions Nominal Power Voltage-VMPP(V) 36.4 36.7 371 374 378 i. 'TEMPERATURE RATINGS' u Nominal Power Current-IMPP(A) 977 982 985 99 994 F- NominaIModuleOperatingTemperature 44°C(±2°C), Open Circuit Voltage Vac(V) 436 43 9 440 441 442 Temperature coefficient of PMAx -0 26%/°C o Short Circuit Current-I (A) 1047 1049 10S2 loss 1058 - sc Temperature coefficient ofVoc -024%/°C _ Power Density(W/m2) 202.85 20571 20857 21142 21428 Temperature coefficient of lsc 0 04%/°C Panel Efficiency(%) 203 206 209 212 214 'The temperature coefficients stated arellnearvalues Lrl Power Output-PMAx(Wp) 271 274 278 282 286 Cil" OO LIGHTBEHAV[OUR Nominal Power Voltage-VMPP(V) 343 346 350 352 356 Typical low irradiance performance of module at STC rn O - . 2 Nominal Power Current-IMPP(A) 789 7"93 796 800 803 ---------- Z _____ z Open Circuit Voltage-V°C(V) 41.1 414 415 416 416 M N _ a o Short Circuit Current-Isc(A) 846 847 850 852 855 ------------------------------------ Values at standard test conditions(STC air mass AM 15,Irradiance 1000 W/m',temperature 25°C),based on a production spread With atolerance ofP.,V°C&Ix±3%within one watt class Nominal module operating temperature(NMOTair mass AMIS,irradiance m — — — — ,� a 80oW/m',temperature 20°C,windspeedIm/s)*Where xxxindicates the nominal power class(P.)atSTC above Irradlance(W/m') m REC Group is an international pioneering solar energy company dedicated to empowering .' ti �.' ttt '�,s a P P g gY P Y P g _ ') i (�• consumers with clean,affordable solar ower in order to facilitate global energy transitions 9"a •ti'. : F1 s�. 1,� P g gY � RCC 4 . Committed-to quality and innovation,REC offers photovoltaic modules with leading high quality, backed by an exceptional low warranty claims rate of less than 100ppm Founded in Norway in 1996, wwwrecgroupcom REC employs 2,000 people and has an annual solar panel capacity of 18 GW With over 10 GW - ., r$•' �r f! installed worldwide,REC is empowering more than 16 million people with clean solar energy REC ■ '■ r:F a.: t ` i,};Tby Group is a Bluestar Elkem company with headquarters In Norway,operational head uartersjn - � •6-.'_ _ :ti t, [ •• <;=�tvSkf Singapore,and regional bases in North America,Europe,and Asia-Pacific" 1 3 Enphase Ncroinverters j IC t{:S,l}�3.Arb.,;>. Irl(,;,-.i Enphase The high-powered smart grid-ready Enphase IQ 7 Micro"' and Enphase IQ 7+Micro" dramatically simplify the installation process while Microinverters achieving the highest system efficiency. Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy", Enphase IQ Battery'M, and the Enphase Enlighten'M monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install ,�_,775 Y ._. Lightweight and simple J0,5 `3 1 Faster installation with improved,lighter two-wire cabling ���•.,:,.;;,,, 11N�YiYli11" �"' Built-in raped shutdown compliant(NEC 2014&2017)-" Productive and Reliable ..r Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed �M Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) *The IQ 7+Micro is required to support 72-cell modules ENPHASE To learn more about Enphase offerings,visit enphase.com ° 0 Enphase IQ 7 and IQ 7+ Micr®inverters a INPUT DATA(DC) I07-60-2-US IQ7PLUS-72-2-US Corrimcinly used module,pafrings�" ;235 W=350 W-+ 285 W 440'W Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maxitiium input DC vaataye'., Peak power tracking voltage 27 V-37 V 27 V-45V Operating range,' Min/Max start voltage 22V/48V 22V/60V Max DC short circuit current(module,lse •15 A''. 15 A° Overvoltage class DC portbk II II bt'port backfeed~current . .„ ... . ,_.._., ,'. 6k PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter W Peak output povuer. .... .,. ..:.r 250 VA a 295 VA Maximum continuous output power 240 VA 290 VA Nominalwovolta . ..... range z 2A0V/ 208Vta ` 244VI< `F 208�tI, 211-2614 V '. „ '1,83-229 V',;, 211-26�V;•;':', .183 229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency, `60^Hz 6D Hz >` » Extended frequency range 47-68 Hz 47-68 Hz A share csrcutt fault current aver 3 cycles 5.8 Arms -5.8 Arles , Maximum units per 20 A(L-L)branch circwt3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltoge class AG part All AC port backfeed current 18 mA 18 mA Poerfactarsettin wg Power factor(adjustable) 0.85 leading..0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208 V @240 V @208 V Pea1'.efftciency 97,6% 97.6% 97.5 .` , 97,3;% „ CEC weighted efficiency 970% 97.0% 97.0% 970% MECHANICAL DATA Ambient temperature range " -400C W+65°C Relative humidity range 4%to 100°b(condensing) Cannectartype-- MC4{or-Amphenol H4 UTX with addttianal i-DSC-5 adapter) „ » Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight ' 1.08k 9(2.38•lbs) 'Coo lirg Natural convection-No fans ;,Approved forwet locations _ Yes Pollution degree PD3 Enolcisure -_' Class IIdouble=insulated,corrosion resistant"polymeric enclosIure- Environmental category/UV exposure rating NEMA Type 6 6ioutdoor m _ s FEATURES Communication Power Line Communication(PLC). Monitoring Enlighten Manager and MyEnlighten monitoring options Both options require installation of an Enphase IQ Envoy. '©isconnecting means The AC ani DC con'nectors.hove freeri eyalusted`and approved by ULfQruse asthe(oed-break, disconneot r6quired by h1EC'690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.1071-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1 No enforced DC/AC ratio See the compatibility calculator at httos//en,phase cont/en usisutznort/rnodule-corn atp rbriity 2 Nominal voltage range can be extended beyond nominal if required by the utility. 3 Limits may vary.Refer to local requirements to define the number of mrcroinverters per branch in your area To learn more about Enphase offerings,visit enphase.com EPIPH SE. IM 2020 Enphase Ene:gy All rights ieserved =nphase,the En;hale logo Ecphase IQ 7,En,)hase Q 7—,Enphase'Q Battery, Enphase En1ghten,Enphase C Envoy,anc otner trademarks or sery ce names are the trademarks of Enphase Energy.Inc Data sioject to cnarige 2020-C-1-05 SERIES . 100 ........... The SnapNrack line of solar mounting systems is designed to reduce total installation costs. The system features technical innovations proven on more than 20OMW of solar projects to simplify installation and reduce costs. Flashed L Foot Simplified ` r= g"'a• 3s�rs ,e' 'gyp.> SnapNrack Series 100 Flashed L Foot Kit is an innovative solution to provide a long lasting watertight seal over the life of the system.The Flashed L Foot provides a single fastener flashed to an attachment composition ; .,Flashed (:`Foot In 3 $Impe Steps: shingle roof with no required cutting of shingles.The L .,I).Locate the ratter-and drift,the pilot hole Foot is engineered for maximum adjustability for a clean ; level installation. ; '2) Prep and attach the lase . " 3),Setthe flashing and attach,the L Foot • 1"slotted bolt connection • 1" spacers available for increased adjustability • Clear or Black anodized aluminum components Place Order through your SnapNrack, (both available with black flashing) distributor, which can be found'at V+Ww.shapnrack,corrf/contact • No Cutting of shingles ij ra Sna ck- Patent Pending 71 Flashed L Foot Kit Assembled(1"spacer sold separately) Flashed L Foot Kit Parts(1"spacer sold separtely) Flasher! L Foot Kit Assembly Flashes! L Foot Kit Dimensions SNAPNRACK CHANNEL NUT SNAPNRACK 92 DEGREE L-FOOT,CLEAR 5/16-18 FLANGE NUT X5/16-18 X LIN BOLT WITH <., / SPLIT LOCK WASHER -SNAPNRACK COMPOSITION FLASHING <sCss �I H 393 s \-SNAPNRACK L-FOOT BASE -, 88 Sna• • L • • Technical Data Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 lbs Design Uplight Load 200 lbs Uplift Design Ultimate Load 1,000 lbs Uplift Warranty 10 Year material and worksmanship Snap"'.,: SERI. _ES, T00 _U 'L .............. oil 1111 1 The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive down costs and improve installation quality on more than 350 MW of solar �' :,xµy x. ";`;€«<s,,� �,;,T" -;`�•;a;:a.gY�^�`ti>a�'<�:s�,�.�:",,f;�� installations. ,=,E:::,`,:, ,^" r.EN. .. Pitched Roof Arrays Simplified ,.: . „aL�t^Y.t The SnapNrack Series 100 UL Roof Mount System is an efficient,visually appealing, photovoltaic (PV) <•`� " s module installation system. Series 100 UL is Listed to the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for 'Roof System in 4 timple Steps: electrical continuity, eliminating the need for additional 1)6o'to the-online Series 100 Configuration grounding hardware. The System's components provide Tool(configure snaporack com)and select an adequate bonding path which has eliminated the "Yes"for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices.The UL 2703 f 2)Identify Site Conditions(Array Tilt,Building, Listing ensures that SnapNrack partners can provide Height,Roof Type'Wind and Snow Loads) the best in class installations in quality, safety, and 3)-Build array in the online"Configuration . efficiency. Tool and automatically generate a-Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor, Purchase matenal•.for a single project or order in,bulb • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules UL LISTED PV !Mounting System Patent Pending 2703 Stainless Boit with Stainless Steel SnapNrack Standard Rail Bolt with Split- SnapNrack on P Split-Lock Washer P Splice Insert Lock Washer SnapNrack Bonding SnapNrack Adjustable End SnapNrack Splice Clamp Top Bonding Base Mid Clamp SnapNrack SnapNrack Bonding Bonding SnapNrack Adjustable End Stainless Channel Nut Bonding Bolt with Clamp Bottom Qk Channel Nut Stainless Hardware with Lock SnapNrack Bonding Split-Lock Washers SpIW Sher Adjustable End Clamp SnapNrack Bonding SnapNrack Bonding Mid Clamp Standard Rail Splice 'SnapNrack Lug 10-6 AWG Copper Wire SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) SnapNrack Bonding Universal " End Clamp(UEC)Wave n, UEC Pull Strap UEC Wedge Stainless Steel Bolt with Flat Washer IF IF F IF IF IF SnapNrack Bonding Universal End Clamp SnapNrack Bonding Standoff Clamp Assembly SnapNrack—)& Serrated Stainless_10 SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar Serrated Stainless Nut Flange Nut Steel Flange Bolt —SnapNrack Stainless SnapNrack Mill Finish 92 Degree Flange Standoff L Foot Bolt SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack Base(1-Hole SnapNrack Base Shown) SnapNrack L Foot Metal Roof Mill Finish Flashing Base Assembly L Foot Base SnapWack Bonding SnapNrack Bonding SnapNrack Metal Standoff Assembly L Foot Base with Flashing Roof Base with Bonding L Foot SnapNrack Series 100 UL Technical Data Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum • Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs. &Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) Snapp, Jack- (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks ©2015 by SnapNrack PV Mounting System All rights reserved Fisher Engineering Services P.C. g 509 Sayville Blvd- Sayville -New York 11782 Phone: (631) 786-4419 February 12, 2021 Attention: Town of Southold Building Department Subject: Engineer Statement for Solar Roof Installation Defeo Residence- 1450 Wickham Ave, Mattituck,NY 11952 I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector system (photovoltaic system) and its installation satisfies the structural roof framing design load requirements of the 2018 International Residential, 2020-Residential Code of New York State (2020 RCNYS), Long Island Unified Solar Permit Initiative (LIUSPI), 2017 National Electric Code,NFPA 70/2014, Weathering Severe, Wind Exposure Category B, Climate Zone 4A. I have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic system for the above residence meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting,the rails shall be securely anchored to the rafters utilizing lag screws that have been designed for wind speed criteria of 130 mph and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geographic design criteria are not applicable to this solar installation. The installation shall be in accordance with the minimum requirements certified by this letter. The existing roof rafters are 2"x6" on 24" c.c., with actual spans of 8'-10", 7'-4" & 13'-10", with plywood roof decking and one roof shingle layer on the house as shown on the drawings. I hope that this letter serves and meets with the approval of the Building Department. Sincerely, NE William G. Fisher, P.E. Licensed Professional Engineer Stv�' Architectural Design-Residential•Light Commercial Additions-Extensions-Conversions Construction Estimates/Oversight-Expediting-Inspections UTILITY METER- oF PLAN KEY SERVICE DISCONNECT - CNet PV-1 SITE PLAN RIDGE RAIL 16'-1 s" _ MAIN SERVICE PANEL- \\� Fs��O VP WIN ROUTER- u v, PHOTOVOLTAIC A-1 PARTIAL LAYOUT MODULE VENT PIPE- O A-2 ROOF ACCESS PLAN INVERTER- 2"X 6"1 24"FOC 9-25" IQ COMBINER W!ENVOY- Eil A-3 CIRCUIT DIAGRAM 16°TILT ENVOY MONITORING ME - E_1 ELECTRICAL ONE LINE %"P RUN PANEL PHOTOVOLTAIC- El �FfSSIONp� DIAGRAM AC DISCONNECT- L-1 LABELING SCHEMATIC _ SUPPLY SIDE CONNECTION- FISHER ENGINEERING SERVICES,P C 5'-0" e'-IB` Rom 509 SA7VILLE BLVD A—BrnN ACCE99 SENSE MONITOR- BM SAYVILLE,NY 11182 2'-0" 36`- WiEw LOao EV CHARGER EV LJGENSE NO 814659/631-186-4419 Cs-1 PHOTOS wdLL OEdwNG wALL � (10)PV MODULES w ROOF SECTION ITTP)-ROOF IA Q 3A TESLA POWERWALL—� @w � lA SCALE NT TESLA GATEWAY- �f' SUNation D EXTERIOR LOCATION-I—) G G "-" solar as it should be MULTIPLE ROOF I STRUCTURE IST FLOOR LOCATION- OST) SUNATION SOLAR SYSTEMS Ill REMINGTON BLVD ROOF IA I 3A VENTILATION-18"- BASEMENT LOCATION- (e) RONKONKOMA NY 11119 RAFTER/SPACING 2"X b"124"OC RIDGE 10-0 VENTILATION-IS'- GARAGE LOCATION - I�> NYSERDA 4 INSTALLER ACTUAL SPAN e'-Ie" PHOTOVOLTAIC NUMBER MODULE SHEATHING PLYWOOD vrvvv CUSTOMER INFO COLLAR TIES NIA DEFIO RESIDENCE TYPE I LAYERS ARCH ASPHALT/ ROOF I ACCESS RooF 2 RAIL 1450 WICKHAM AVENUE RAFTER (I e)PV MODULES MATTITUCK, NY 11952 O C RAFTER/SPACING 2"X 6"124'O C 26"TILT JOB NUMBER ACTUAL SPAN I'-4" �'-4" 21' UAL BOFFlT SHEATHING PLYWOOD ACTSPAN 21 ro4c3 EMEIbOR WALL COLLAR TIES NIA ROOF SECTION(TYP)-ROOF 2 DATE .21 TYPE/LAYERS ARCH ASPHALT/I SCALE N T S EGRESS ACCESS 2.11 -36"- ROOF IB T 35 JOB NOTES QROOF I WA RAFTER I SPACING 2"X 6'124'OC _= ACCESS (EM) -36"- v v ACTUAL SPAN 13'-10" RIDGE 16-I 5` c (B) SHEATHING PLYWOOD PHOTOVOLTAIC = MODULE 5 U $P COLLAR TIES WA TYPE/LAYERS ARCH ASPHALT/I (6)PV MODULES FRONT OF HOUSE-FACING STREET OR DRIVEWAY RAFTER RAIL 2"X 6"124 0 BUILDING REVIEW NOTE NOTES 515TERED WITH 2"X 6- 20*TILT TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE I THI5 PV SYSTEM HAS BEEN DESIGNED TO MEET ALL 1U S, ,b• ENCLOSED DOCUMENT FOR MINIMUM ACCEPTABLE CURRENT AND APPLICABLE FIRE PREVENTION ACTUAL SPAN 90FRT E ERIOR WA PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SETBACK PAThWAYS PER 2020 NY$RESIDENTIAL ROOF SECTION(TTP)-ROOF IB 30 SPECIFIED IN THE BUILDING AND/OR RESIDENTIAL CODE.PROPER GROUND CLEARANCE,ROOF MODEL REG REG360AA BLACK SCALE NT s CODE OF THE STATE OF NEW YORK THIS REVIEW ACCESS POINTS,ACCESS PATHWAYS,AND ADDITIONAL MATERIALS FASTENER REQUIREMENTS. DOES NOT GUARANTEE COMPLIANCE WITH THAT CODE VENTILATION SHALL BE PROVIDED WHERE 1 NIA 360 WATT EA THAT RESPONSIBILITY IS GUARANTEED UNDER THE NECESSARY AN IN DEPTH DESCRIPTION OF EACH 61 8"L X 40"W X 1.2'D, 18.83 FT' TOTAL ARRAY AREA=499 SF SEAL AND SIGNATURE OF THE NEW YORK STATE APPLICABLE CODE REFERENCE AND EXCEPTION 43#/MODULE (2.3#/SF)12/2020 WIND LOAD ASCE 10(SEE CALCULATIONS, THIS SHEET)41 5 LICENSED DESIGN PROFESSIONAL OF RECORD THAT FOR ANY CODES 15 DEPICTED ON THE A-2 PLATE OF MODULE (26)REC369AA BLACK PSF MAX SEAL AND SIGNATURE HAS BEEN INTERPRETED A5 AN THIS DRAWING PACKAGE MICRO INVERTER (26)ENPHASE IQIPLUS-12-2-US ATTESTATION THAT, TO THE BEST OF THE LICENSEE'S BRANCH#I I(IXIO) TOTAL UPLIFT=41.5 PSF X 499 SF=20, 16.8 LBS 2 ROOF SHALL HAVE NO MORE THAN A SINGLE BELIEF AND INFORMATION THE WORK IN DOCUMENT IS LAYER OF ROOF COVERING IN ADDITION TO THE BRANCH#3 2(1><&) FASTENER B BRANCH#2 3(1X1 e) a ACCURATE SOLAR EQUIPMENT DRAWN Y • CONFORMS WITH GOVERNING CODES APPLICABLE RACKING SNAP'N'RAGK-ULTRA RAIL AT THE TIME OF THE SUBMISSION 3 INSTALLATION OF SOLAR EQUIPMENT SHALL BE BUTERA PACKAGE STANDARD (1)SNAP 'N' RACK L-FOOT I FLASHING ASSEMBLY FLUSH-MOUNTED, PARALLEL TO AND NO MORE • SYSTEM RATING CDG 936 KW (1)5/16" DIAMETER 203.2,8/04 LAG BCONFORMS WITH REASONABLE STANDARDS OFOLT W/ FLAT WASHER THAN 6-INCHE5 ABOVE THE SURFACE OF THE REVISION EST PRODUCTION CAG 9,860 KWH/YR LAG BOLT WITHDRAWAL VALUE 5116" DIA, 266 L5/IN X 2-INCH THREAD DEPTH = PRACTICE AND WITH VIEW TO THE SAFEGUARDING ROOF. DATE DESIGNER NOTE EST PRODUCTION SOURCE AURORA OF LIFE, HEALTH,PROPERTY AND PUBLIC 5321-5. CAP PER LAG BOLT WELFARE IS THE RESPONS151UTY OF THE LCENSEE 4 WEIGHT OF THE INSTALLED SYSTEM SHALL NOT XXXX.XX NIA WA SPECIAL ATTACHMENTSI NIA MINIMUM NUMBER OF LAG BOLTS REQUIRED =20,-116.8 L55 /532 L55/LAG BOLT =23 EXCEED MORE THAN 5-PSF TOTAL RAIL FEET=210 RAIL FT/ 23 BOLTS =9'-0" 5 ANY PLUMBING VENTS ARE NOT TO BE CUT OR XxXxxx NIA NIA MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS"X" USE 4'-0" MAX STRUCTURAL STATEMENT COVERED FOR SOLAR EQUIPMENT INSTALLATION XXXXXX NIA NIA ANY RELOCATION OR MODIFICATION OF THE CLIMATIC I GEOGRAPHIC DESIGN CRITERIA - TABLE R301.2(1) THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT VENT REQUIRES A PLUMBING PERMIT ANDS` WA WA THE NEW LOADS IMPOSED 5Y THE PHOTOVOLTAIC INSPECTION SCALE WIND DESIGN SUBJECT TO DAMAGE MODULE SYSTEM INCLUDING UPLIFT I SHEAR. THE EXISTING RAFTER SIZES � DIMENSIONS CONFORM TO N.T.S. WIND WIND ICE THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE SPECIAL SEISMIC CLIMATE FROST WINTER AIR MEAN IRC-2018 TABLE 8802 41CI)-RAFTER SPANS GROUND SPEED TOPOGRAPHIC WIND EXPOSURE BORNE DESIGN WEATHERING LINE TERMITE DESIGN BARRIER FLOOD FREEZING ANNUAL MINIMUM DESIGN STANDARDS FOR BUILDING AND TITLE SITE PLAN SNOW LOAD (MPH) EFFECTS REGION CATEGORY DEBRIS CATEGORY ZONE DEPTH TEMP UNDERLAYMENT HAZARD INDEX TEMP OTHER STRUCTURES OF THE ASCE-1-le AND THE ZONE REQUIRED MOUNTING BRACKETS AND HARDWARE MEET 2020 NEW YORK STATE RESIDENTIAL CODE 26 PSI; 130 B NO B 2 G dA SEVERE 3=e" TO D EXCEED NEW YORK STATE CODE REQUIREMENTTSS FOR 15 DEG NA PLANS 599 51 THE DESIGN CRITERIA OF THE TOWN HEAVY EXAMINER Pv= GUTTER OF�NFIy/ Roof 3B Roof 3A \\ 'P O ONP�- // 3/4"SPACING I BETWEEN ROW5 FISHER ENGINEERING SERVICES,PG SE N SAl'VILLE BLVD SAYVILLE,NY II1e7 I LJCEt19NO 814659 1 631-186-4419 I I I suNatoon Solar as It should be /f ^ SU14ATION SOLAR SYSTEMS jLZ X 4)a= Ill BLVD I � RONKONKOMA NKOMA N.Y 11-11'a , 114 W W r w H INSTALLER w a (3) BOH NORTH ROOF NUMBER o CUSTOMER INFO DE US 51° TRUE; 16 TILT; 3/12 PITCH RESIDENCE C10) MODULES x o 1450 WICKHAM AVENUE LU v RIDGE MATTITUCK, NY 11952 23 JOB NUMBER / i / / / / / / / / 7 /-77 / / / / 21 ro4cJ I { DATE PARTIAL HOUSE ROOF PLANvvv ;v 2.1 1.21 I I SCALE: 3/16 — 1'e" j j ATTACHMENT SPACING N I I PHOTOVOLTAIC ROOF a MAbM ATTACHMENT SPACING MODULE(TYP) 1 48` I I � I I 7 48` 3 de" 5NAP'N'RACK SYSTEM (TYPICAL RAIL ACRO55 I I EACH ROUT OF ARRAY) /� i /\ (ONLY TWO SHOWN FOR CLARITY) _ I _ / NOTES U / °°w N°w°X (1) FOH SOUTH ROOF NIA w N i w° 231' TRUE; 16° TILT; 3/12 PITCH I w @ N W N (1 e) MODULES N I u GUTTER Roof to Roof 1B Roaf 1A 23' HOUSE DRAWN BY jp Uj / BUTERA REVISION DATE DESIGNER NOTE wXXXXXX.�`�' Nl<. - NIA NIA XXXX XX N/A NIA / XXXXXX NIA NIA (2) FOH LOUDER SOUTH ROOF SCALE 231* TRUE; 2e' TILT; 4/12 PITCH 3/1(0 (6) MODULES TITLE PARTIAL LAYOUT ROOF AREA Aml R324 6 ROOF ACCESS AND PATHWAYS-ROOF ACCESS, PATHWAYS AND SETBACK REQUIREMENTS �� OF SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS F 8324 61 THROUGH 8324.6 21 �Q���°m G. Fs �O EXCEPTI ON(5k 1 DETACHED, NONHABITABLE STRUCTURES, INCLUDING BUT NOT LIMITED TO DETACHED O GARAGES, PARKING SHADE STRUCTURES, o CARPORTS, SOLAR TRELLISES AND SIMILAR ESS10 STRUCTURES, SHALL NOT BE REQUIRED TO PROVIDE ROOF ACCESS 2. ROOF ACCESS, PATHWAYS AND SETBACKS NEED FISHER ENGINEERING SERVICES,PC NOT 8E PROVIDED WHERE THE 6UlLD1NG OFFICIAL 5B9 SAYVILLE BLVD 11182 HAS DETERMINED THAT ROOFTOP OPERATIONS E NO 0146 NY 31-15 LIGENBE NO B1d699/631-1Bb-4419 WILL NOT BE EMPLOYED 3 THESE REQUIREMENTS SHALL NOT APPLY TO �������� ROOFS WITH SLOPES OF TWO UNITS VERTICAL IN 12 UNITS HORIZONTAL(I'1-PERCENT SLOPE)OR LESS Solar as It should be SUNATION SOLAR SYSTEMS 83246.1 PATHWAYS _ III REMINGTONBLVD 1 NOT FEWER THAN TWO PATHWAYS, ON SEPARATE RONKONKOMA NY 111-It ROOF PLANES FROM LOWEST ROOF EDGE TO ROOF NYSERDA ` RIDGE AND NOT LESS THAN 36 INCHES (V4 MM) ACCESS INSTALLER i✓.� WIDE, SHALL BE PROVIDED ON ALL BUILDINGS. -36 - NUMBER 2 NOT FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE CUSTOMER INFO OF THE ROOF. (I8) PV MODULES DEFIO RESIDENCE 3 FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, A PATHWAY NOT LESS THAN 36 INCHES 1450 WICKHAM AVENUE WIDE(914 MM)SHALL BE PROVIDED FROM THE MATTITUCK, NY IIS52 LOWEST ROOF EDGE TO RIDGE ON THE SAME AV\V\L- ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, JOB NUMBER� ���0�9 ON AN ADJACENT ROOF PLANE, OR STRADDLING THE SAME AND ADJACENT ROOF PLANES 4. PATHWAYS SHALL BE OVER AREAS CAPABLE DATE OF SUPPORTING FIRE FIGHTERS ACCESSING THE VENTILATION - 18 - 2. ,21 ROOF. 5 PATHWAYS SHALL BE LOCATED IN AREAS WITH VENTILATION-- I8 - NOTES MINIMAL OB5TRUCTIONS SUCH AS VENT PIPES, I N/A CONDUIT, OR MECHANICAL EQUIPMENT. 6 PATHWAYS ON OPPOSING ROOF SLOPES SHALL NOT BE LOCATED ALONG THE SAME PLANE AS THE TRUSS,RAFTER, OR OTHER SUCH FRAMING SYSTEM THAT SUPPORTS THE PATHWAY vvvvv EXCEPTION(S> 1. ACCESS PATHWAYS SHALL NOT BE REQUIRED ON ROOF SLOPES CONTAINING PHOTOVOLTAIC MODULES, PANELS, OR AN ARRAY WHERE THE ROOF OPPOSING OR ADJACENT ROOF SLOPE IS AN ACCESS ACCESS ROOF ACCESS ROOF A ROOF SURFACE THAT• (I0) PY MODULES omm "vmmv 1 CAN BE ACCESSED FROM THE GROUND BY THE FIRE SERVICE 2. IS CAPABLE OF PROVIDING FIRE SERVICE ACCESS TO THE RIDGE OR PEAK OF AN OPPOSING OR ADJACENT ROOF SURFACE THAT CONTAINS PHOTOVOLTAIC MODULES, PANELS, OR AN ARRAY 3. IS RELATIVELY FREE OF VENTS, SKYLIGHTS, CONDUITS, MECHANICAL EQUIPMENT,AND OTHER SUCH OBSTRUCTIONS 4. DOES NOT CONTAIN PHOTOVOLTAIC MODULES, EGRESS ACCESS DRAWN BY PANELS,OR AN ARRAY, OR,IS A SINGLE RIDGE -3y"- BUTERA ROOF WHERE THE MAXIMUM EDGE TO EDGE WIDTH REVISION OF THE PHOTOVOLTAIC PANEL SYSTEM DOES NOT v DATE DESIGNER NOTE EXCEED 33 PERCENT OF THE RIDGE LENGTH ROOF y-_ y xxATE ICN NIA _ _ ' T�1-1 8324.62 SETBACKS AT RIDGE �Q AGGESS _ I. PHOTOVOLTAIC ARRAYS SHALL NOT BE (EXT.) AG -36 xxXxxx NIA NIA XX.XX NIA NIA LOCATED LESS THAN IS INCHES (451 MM)FROM DSG xxxxxx A HORIZONTAL RIDGE NIA NIA SCALE 8324.6 2 2 EMERGENCY ESCAPE AND RESCUE OPENING SSG UM SP I PANELS AND MODULES INSTALLED ON DWELLINGS N.T.S. SHALL NOT BE PLACED ON THE PORTION OF A TITLE ROOF ACCESS PLAN ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING (6) PV MODULES 2. A PATHWAY NOT LE55 THAN 36 INCHES (914 MM) WIDE SHALL BE PROVIDED TO THE EMERGENCY A � ESCAPE AND RESCUE OPENING FRONT OF HOUSE - FACING STREET OR DRIVEWAY 2 OF NFly G.FP���0 r 1 FESSIo FISHER ENGINEERING SERVICES,P C 599 SAYVILLE BLVD 5AYVILLE,NY 11152 LICENSE NO 614659/631-lab-44M -07 SUNation 0 ®° SOlar as It should be SUNATION 50LAR SYSTEMS Ill REMINGTON BLVD RONKONKOMA NY 11779 ROOF ACCESS NSTAI ` INSTALLER j`�+/ -36 NUMBER CUSTOMER INFO CIRCUIT TWO DENO RESIDENCE 1480 WICKHAM AVENUE =- MATTITUCK, NY 11,552 ❑ JOB NUMBER 21645 DATE VENTILATION - 1&" — 2,11,21 VENTILATION'— IS" NOTES - I WA c Poor- ACCESS OOFACCESS - CIRGUIT ON ,EGRESS ACCESS DRAWN BY BUTERA REVISION _ DATE DESIGNER NOTE IG2 ROOF >oc>oe>0< WA NIA ACCESS -- >01001OCX N/A N/A (EXT.) XXXX N/A N/A ZG (B) DS XXXCXk NIA WA ......... ........•• SCALE s- UM MSP N.T.S. TITLE CIRCUT DIAGRAM - CIRCUIT THREE _ - A=3 FRONT OF HOUSE FACING STREET OR DRIVEWAY o F NFA O n Sill FI5I-IER ENGINEERING SERVICES,PC 509 SAYVILLE BLVD 5AYVILLE,NY 11182 LJGENSE NO 814659)631-186-4419 UTILITY SERVICESUNation Solar as it should be I 2 9 10 SUNATION SOLAR SYSTEMS Ill REMINGTON BLVD VNEN • SUPPLY TIDE PHASE RONKONKOMA KY 111-15 ICRO O _ = NYSERDA n N VERTER N N INSTALLERYP) NUMBER MODULE J-BOX (TYP) PLAQUE PLAQUE CUSTOMER INFODEFIO RESIDENCE SERVICE DISCONNECT SERVICE DISCONNECT CIRCUIT I IQ COMBINER PANEL 2 OF 2 1 OF 2 PV MODULE (ACTIVATES RAPID SECOND DISCONNECT 1450 WICKHAM AVENUE ENPHASE ENVOY SHUTDOWN) LOCATED NEXT TO (TYP) ATTIC No�oaob—T— PRIMARY DISCONNECT 100JOB A METER PAN MATT015 NU NMBERR 11952 STRING OF 2 LOCATED IN MAIN MAIN I NU (I0)REG REC360AA BLACK U)/ ROOF MOUNTED �, SERVICE PANEL 21/4S (10)ENPHASE IQIPLUS-I2-2-US 50LADEGK 2P 2eA 1� I 2 MICRO-INVERTERS IN PARALLEL 9 10 �, DATE • I r-q I 2P 20A �1 ENCLOSURE I,,,LII I �1 2P 10A SERVICE RATED 60A MIN.66A NOTES Lv C C N — — — —— ———— 2P 20A OCPD MIN 22K AIG I N/A I I I MAIN SERVICE CIRCUIT 2 I EXTERIOR WALL I PANEL I 4 6 I STRING OF (10)REG REC360AA BLACK w/ i CONDUIT AND CONDUCTOR SCHEDULE (le)ENPHASE I0I1"LUS-I2-2-US 1 2 MICRO-INVERTERS IN PARALLEL 5 6 I TAC: DESCRIPTION OR CONDUCTOR NUMBER OF CONDUIT CONDUIT RUN BUILDING CONDUCTOR TYPE GAUGE CONDUCTORS TYPE SIZE LENGTH GROUNDING I 1 NPHASE Q-CABLE 12 6 NIA NIA 15, ELECTRODE N � rti N I 2 TYPE NM 10 6 NIA NIA 30' 3 HWN-2 10 6 PVC, SGH. 80 1.25" 24' . . . . . . . 3EC 6 1 PVC SGH 80 1.25" 24 CIRCUIT 3 I 4 HWN-2 6 3 PVC SGH 80 1.25" 4 r.EC 6 1 PVC SGH. 80 1.25" 4" STRING OF (6)REC REC36eAA BLACK W/ 5 HWN-2 (0 3 PVC SCH $0 (6)ENPHASE IQIPLUS-l2-2-US EGG ATTACHED (O EC (o I NIA NIA $ MICRO-INVERTERS IN PARALLEL TO RAIL(TYP) DRAWN BY BUTERA SCALE N.T.S. TITLE ONE-LINE DIAGRAM E- 1 b - 0:- SUNation I Solar as it should be SUNATION 50LAR SYSTEMS Ill REMING70N BLVD. RONKONKOMA N.Y.II11S NTALLE INSTALLER NUMBER - - CUSTOMER INFO DEFIO RESIDENCE 1450 WICKHAM AVENUE MATTITUCK, NY 11952 - JOB NUMBER 21 ic49 DATE = 2.11.21 - NOTES t 4" ARRA' LOCATIONS ARRAY LOCATI(-*')N5 SATELLITE IMAGE VIA GROUND VIA ROOF fo 098299377><euuwao,ura Ili . ■Nu.nmwwumul IbL r — "�socue nxn� Iii�iRtiNt� --°^ DRAWN BY 15MERA SCALE N.T.S. 5OUTH VIEW PROPOSED EXISTING METER TITLE PHOTOS VIA ROOF EQUIPMENT LOCATION AND MDP G= 1 T SUN TAG LABEL QTY. LOCATION NOTE EXAMPLES SUNATION SOLAR SYSTEMS Ill REMINGTON BLVD. RONKONKOMA N.Y.MITI e02-314.O 201+NECn8931(Gk31 1 0 EVERY SEPERATION BY ENCLOSURES/WALLS/! • • IZ CONDUITS '� ■���+ NYSERDA • PARTITIONS/GEIUNGS/FLOORS OR NO MORE THAN 10� INSTALLER 410'5-326 2014 NEC 690.33(EI(2) O ^��"�'•�- s y NUMBER �/✓ CUSTOMER INFO � - - DEFIO RESIDENCE DO NOT DISCONNECT 1 SPLICE/COMBINER I A ANY COMBINER BOX IF USED UNDER LOAD 1450 WICKHAM AVENUE F MATTITUCK, NY 11,552 -- - £ •• + JOB NUMBER 21649 1 CIRCUIT 1 7sp-Igs4 __ __ DATE :i SUN,Tw+ I 2.11.21 750.9454 >- NOTES • + + . • a .. 1 OF EACH A AG D15CONNECT © 12.1 CIRCUIT 2 3 SOURCE CIRCUITS COMPLETE VOLTAGE AND CURRENT VALUES ON NIA 240.0 DISCONNECT LABEL . . . AS NEEDED Im7.26 CIRCUIT 3 240.0 Immumma W. 240.0 1105702 2014 NEC Ew)171E) Service DisconneWARNING I AC SERVICE I OF EACH A FUSED AG DISCONNECT OELECTRIC SHOCK HAZARD DISCONNECTING COMPLETE VOLTAGE AND CURRENT VALUES ON 16,111IN162,1. 00 NOT 10UCH TEtilli MEANS D15CONNECT LABELP—ory Service Disconnect wnRNINa iElMWLL6 ON BOTH THE I"A,_ LOW•tom y4v N EME111iLocated in Main Service Panel N 11E OPEN tY;git011 __ - .... . C. ,,:r, B IlitNoProdw d Ewc t:Power • PreducUm 1 1 i 1 lt:W■r f+4sto ven■fe awfr_— OY+� _— O — I MAIN DISCONNECT I OF EACH A BUILDING MAIN DISCONNECT PANEL PANEL Service Disconnect D .. Locatog no-1 to MOW Pah dl 9 This t3uNdaig u equipped with an Intercon rated EI$Cft Paver DRAWN BY Production Source 11 i 1 T A O saim�H■+. E sa■r�h■.■aen■� I UTIUTY METER I A PSEfG UTILITY METER E SCALE- urs�.auiaorm•.�,... ..� .r.s. sH...�.w s.r.ati.+.....Wim- TITLE:LABELING SCHEMATIC sa+-iso-•4s4 L- 1