HomeMy WebLinkAbout45264-Z ��o�OS�FPO(K�pGy Town of Southold 3/27/2021 P.O.Box 1179 W 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41909 Date: 3/27/2021 THIS CERTIFIES that the building ALTERATION Location of Property: 145 Old Field Ct,Mattituck SCTM#: 473889 Sec/Block/Lot: 120.-3-8.19 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/22/2020 pursuant to which Building Permit No. 45264 dated 9/30/2020 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: finished basement to existing single-family dwelling as applied for. The certificate is issued to Spieler,Michael&Kerri of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45 4 1/25/2021 PLUMBERS CERTIFICATION DATED Aut riz S' tore TOWN OF SOUTHOLD Fo�,rBUILDING DEPARTMENT TOWN CLERK'S OFFICE, . ,� SOUTHOLD, NY a BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45264 Date: 9/30/2020 Permission is hereby granted to: Spieler, Michael 11, Sherman Ave Rockville Centre, NY 11570 To: construct additions/alterations (finish basement) to existing single-family dwelling as applied for. At premises located at: 145 Old Field Ct, Mattituck SCTM # 473889 Sec/Block/Lot# 120.-3-8.19 Pursuant to application dated 9/22/2020 and approved by the Building Inspector. To expire on 4/1/2022. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $467.60 CO -ALTERATION TO DWELLING $50.00 Total: $517.60 Bui ding n pector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN ITALY, 765-X802 A#PL-ICATION FOR CERTIFICATE OF OCCUPANCY -This application must be filled in by typewriter brink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location-ofall buildings,property lines,•streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water-supply and sewerage-disposal(S-9 form). 3. Approval of electrical in from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains_less than-2110 of,,l%lead. 5. Commercial building,,industrial building,multiple residences and similar.building's-and:installations;a,certifcate of Code Compliance from architect or-engineer responsible for the building.- 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses,or buildings-and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the•Building'Inspector shall state the reasons therefor in writing to the applicant: C. Fees 1. Certificate of Occupancy,-.New,dwelling'$50.00,Additions to-dwelling$50.00,Alterations to,dwelling$50.00, Swimming pool$50.00,_Accessory building-$50.00,Additions to accessory building$50.60,Businesses$50.00. 2. Certificate of Occupancy-on Pre-existing Building- $100.06 3. Copy of Certificate of Occupancy;w$:25 4. Updated Certificate'of Occupancy--$50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date.- <,—v4wep?ber 10 202-0 New Construction: j�/r _Old or Pre-existing-Building I (cl e_ck=one) ,/�J _J� Location'of Property: 1 7 7 0_ /d -=I e ice` Co`t 0_r +'t`�" "aC, .House.No. Street -Hamlet Owner or Owners of Property: � 1-�, Suffolk County" Tax Map No 1000,Section /20 Block 3 Lot $• t Subdivision G 1 Filed Map. Loot: Permit No.�J Date of Permit. Applicant: Health'Dept.Approval: IV/14 Underwriters Approval: Planning Board Approval:. R1A Request for: Temporary- -C1ertificate Final-Certificate: (check one) 'Fee Submitted:$ L)U Applicant Signature k*rjf So Town Hall Annex Telephone(631)765-1802 54375 Main Road . _ R `zJ' Fax(631)765-9502 P.O.Box 1179 sean.devlin(a)town.southold.ny.us Southold,NY 11971-0959 �® BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Michael Spieler Address: 145 Old Field Ct city.Mattituck st: NY zip: 11952 Building Permit#: 45264 Section- 120 Block: 3 Lot: 8.19 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Lombardi Electric License No: 2779ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Commerical Outdoor X 1st Floor Pool New X Renovation X 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 18 Ceding Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 2 Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures 19 CO2 Detectors Sub Panel A/C Blower Range Recpt Ceding Fan Combo Smoke/CO 2 Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 9 4'LED Exit Fixtures Pump Other Equipment: Notes: Finished Basement Inspector Signature: Date: January 25, 2021 S.Devlin-Cert Electrical Compliance Form As qf so L4 TOWN OF SOUTHOLD BUILDING DEPTE 765-1802 INSPECTION FOUNDATION 1ST ROUGH PL13G. FOUNDATION-2ND INSULATIOWCAULKING FRAMING/STRAPPING FINAL FIREPLACE-& CHIMNEY FIRE SAFETY INSPECTION FIRE RESISTANT CONSTRUCTION FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) ELECTRICAL (FINAL)� CODE VIOLATION PRE C/O REMARKS: �ln DATE — INSPECTOR ul � OF SOGT - - --- -------_` ' f 0 yo# y TOWN OF SOUTHOLD BUILDING DEPT. coorm 765-1802 INSPECTION [ ] FOUNDATION IST [ ] ROUGH PLBG. UNDATION 2ND = [ INSULATION/CAULKING [ FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ]" FIRE RESISTANT PENETRATION' [ ]- ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMA KS: ac DATE ©� Or �- INSPECTOR - SOUI�olo ` la[ 1 L� o # # TOWN OF SOUTHOLD BUILDING DEPT. `ccourm��' 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG., ] FOUNDATION 2ND [ ] INSULATION/CAULKING- [ ] FRAMING /STRAPPING [ ] FINAL [ ] -FIREPL"ACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE I °� INSPECTOR ��� ��OF SOUTyO # # TOWN OF SOUTHOLD BUILDING DEPT. cou765-1802 _INSPECTION [ ] FOUNDATION 1ST [ ] RO GH PLBG. [ ] FOUNDATION 2ND [ ] SULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION " [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL-(FINAL) [ ] CODE VIOLATION [ ] PRE C/O �v v7 MARKS: _ Y bra 1w ri o <1�vs, p z p DATE INSPECTOR �Y t C. *r. 6 FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(IST) ------------------------------------ FOUNDATION(2ND) l Ogg 4� ROUGH FRAMING& $ PLUMBING S� INSULATION PER N.Y. STATE ENERGY CODE 1�! Vilir Am Lu I An FINAL AD.DI''10NAL, C9MMENTS- 00-C1-NIfD i$ -aeloc ,Uo reg# ..��b� �, 7 yo - rd TOWN-OVSOUTHOLD BUILDING PERMIT APPLICA'T'ION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 .4 sets of Building Plans TEL:(631)765=1802 Planning Board approval FAX:(631)765-9502 Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examtned 9136 20 'Single&s Separate Truss Identification Form r Storm-Water Assessment Form nContact: Approved 20t�" Mail to. Disapproved a/c Phone:' Expiration 20,� ns ctor LWATION FOR'BtUDING PERMIT SEP 2 2 2020 Datb—SOj Cr �O ,20 20 INSTRUCTIONS V �,�9s3P'01TQiPdW1 'be completely'filled in by typewriter or in ink and submitted to the Building Inspector with 4 set a f plans;accgrate-p�ot; IAO le.Fee according to schedule. b.Plot pfan Showing tocatton of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.-The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval_of this application,the Building Inspector will.issue a Birtlding Permit to the applicant.Such a permit shall be kept on the premises available'foi inspection throughout the work.. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire-if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize;in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. -APPLICATION IS HEREBY MADE to the Building Department for the issuance of a•Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York ,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as,herein described.The, applicant agrees to comply with'all applicable laws,ordinances,building code,housing code,and regulations,and to admit. authorized inspectors on premises and in building for necessary inspections. %(ice(SSSiignaturee.of applicant or name,if a corporation)- X ll ,Skmpl? Ova, I1570 (Mailing address�of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber-or builder r Name of owner of premises'X (As on the tax roll or latest deed) If applicant is•a corporation,signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No: Electricians License No. Other Trade's License No. 1.• Location of land on whic proposed work will be done: 115 C, .I pieId Court- fila4i`hAcK House Number" Street Hamlet County Tax Map No.1000 Section 120 Block 3 Lot 43. 17 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction, a. Existing use and occupancy 'Rcs-.A e m2C.e b. Intended use and occupancy ]10 6!4e- 3. Nature of work(check which applicable):New Building Addition Alteration_ Repair Removal Demolition Other Work (Description) 4. Estimated Cost 101000 Fee - q (Tobe paid on filing this application) 5. If dwelling,number of dwelling units 1 Number of dwelling units on each floor /A, _ If garage,number of cars *2- 6. 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. y 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories 2— Dimensions-of Dimensions-of same structure with alterations or additions:Front v? a Rear- Depth Height Number of Storie .8. Dimensions of entire-new construction:Front N Rear Depth Height Number of Stores 9. Size of lot:Front /25+ Rear 125 Depth ?20' I 10.Date of Purchase )( SV1 �o Name of Former Owner x 11.Zone or use district in which premises are situated / 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO V 13.Will lot be re-graded?YES_NO /Will excess fill be removed from� Prg�ise�s9 YES—NO,�(r( lHS of � pc.l �¢I X516 q56-(Wa 14.Names of Owner of premisesx Address Phone No.X Name of Architect ,YoS001 Bello Address mro tva S7-E Phone No Sib 308 Name of Contractor Address Phone No. a / 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO *IF YES,SOUTHOLD TOWN TRUSTEES'&D.E.C.PERMITS MAY BEQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D:E.C.'PERMITS MAYBE REQUIRED. -16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property-'is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO *IF YES,PROVIDE A,COPY. SPIELER KAUOPE NOTARY PUBLIC STATE OF NEW YORK STATE OF NEW YORK) NASSAU COUNTY COUNTY N COMM.EXP��,�t 3 �v being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the O(,y> er (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his-knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Swom to before me this day of, S Plo_h�-r 20 x )(=� elp±=� X Notary Public Signature of Applicant .f ��SpFFpCKCo BUILDING DEPARTMENT- Electrical Inspector �O GymTOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 CD "' - Southold, New York 11971-0959 4,- p Telephone (631) 765-1802 - FAX (631) 765-9502 rogerr(c�southoldtownny.gov sea nd6E�southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: Company Name: cam` C Name: License No.: M email: Address: k 0 V 1e10r &r( 4 Phone No.: 5- JOB SITE INFORMATION (All Information Required) Name: Address: D( ridl C�- Cross Street: Phone No.: ,5(6 Bldg.Permit#: 4 '�L 6 email: Tax Map District: 1000 Section: 2,> Block: 3 Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) f" Ig,54 �6S5cA,,, Circle All That Apply: Is job ready for inspection?: NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect - Flood Reconnect- Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Form As I l%" PERMIT# Address: Switches I Outlets 1 G F I's 1� Surface Sconces HH's �Y UC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator Combo I Cooktop Transfer AC AH Mini Special: Comments 0 GENERAL NOTES: . ¢ THE WORK UNDER THIS CONTRACT SHALL CONSIST OF ALL LABOR INSTALLATION,MATERIALS AND EQUIPMENT REQUIRED AND NECESSARY TO PERFORM ALL 125'0 WORK A5 SHOWN ON THE DRAWIN65 SPECIFIED HEREIN AND AS REQUIRED BY CONDITIONS AT THE 51TE: - - - - - - - - - ALL WORK SHALL COMPLY WITH THE:2010 NEW YORK STATE RESIDENTIAL CODE LATEST ADDITION AND ALL OTHER LOCAL CODES AND AGENCIES HAVING JURISDICTION. ELECTRICAL. ALL WORK SHALL CONFORM TO THE 'AMERICAN FOREST AND PAPER ASSOCIATION(AF 8 PA)WOOD FRAME CONSTRUCTION MANUAL FOR ONE AND TWO APPROVED AS NOTED INSPECTION REQUIRED FAMILY DWELLING(WFGM)AND ALL OTHER LOCAL CODES AND AGENCIE5 HAVING JURI50IGTION. 6334 Northern Boulevard DATE: B,P,# I East Norwich, New York 11732 ALL WORK SHALL CONFORM TO THE NEW YORK STATE UNIFORM FIRE PREVENTION AND BUILDING CODE AND ALL OTHER LOCAL CODES AND AGENCIES FEE: 111166 BY: I -•- HAVING JURI5DIGTION. NOTIFY BUILDING r,F'PARTMENT AT 11 Broadway - Suite 3 ALL WORK SHALL CONFORM TO THE NEW YORK STATE ENERGY CONSERVATION GORE(LATEST EDITION)AND ALL OTHER LOCAL CODES AND AGENCIES 65-1802 8 AM TO 4 PM FOR THE Amityville, New York 11701 HAVING JURISDICTION. FOLLOWING INSPECTIONS: ALL ELECTRICAL WORK SHALL CONFORM TO THE REQUIREMENT5 OF THE NATIONAL ELECTRICAL CODE AND THE NEW YORK STATE CODE,AND ALL OTHER 1. FOUNDATION - TW) REQUIRED LOCAL CODES AND AGENCIES HAVING JURI5DIGTION. °,,.,_T FOR POURED C"RI„-��E 'Blower door 516.3 08.4 6 4 6 P h o n e ALL PLUMBING WORK SHALL CONFORM TO THE NEW YORK STATE PLUMBING CODE REQUIREMENTS AND ALL OTHER LOCAL CODES,ORDINANCES AND AGENCIES 2. ROUGH - FRAMINC, PLUMBING 516 . 8 13 . 0 9 2 4 F a x HAVING JURISDICTION AND TO THE 5TANDARD5 OF THE NA55AU COUNTY HEALTH DEPARTMENT. 3. INSULATION and ductwork Info@Joe BelloArchitects.com NOTIFY ALL CORPORATIONS,ADJACENT PROPERTY OWNERS,UTILITY COMPANIE5 AND/OR LOCAL AUTHORITIES OWNING CONDUIT,WIRE5,PIPES OR OTHER 4. FINAL - CONSTRUCTION MUST testing required. www.JoeBeIloArchitects.com UTILITIES RUNNING TO OR ON THE PROPERTY OR IN THE AREAS AF=EGTED BY TH15 CONSTRUCTION AND/OR OTHEFA15E REQUIRED BY THE TOWN OR LOCAL BE COMPLETE FOR C.O. AGENCIES HAVING JURISDICTION. GAP ALL ABANDONED UTILITY LINES IN ACCORDANCE WITH THE INSTRUCTIONS FROM UTILITY COMPANIES OR LOCAL AUTHORITIES HAVING JURISDICTION. ALL CONSTRUCTICIN SHALL MEET THE EXISTING FLOOR STRUCTURE. PROVIDE SMOKE,HEAT DETEGTOR5,AND CARBON MONOXIDE DETECTORS AS REQUIRED BY CODE. REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR EXI5TING EXTERIOR WALL DATE ISSUED: THE GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR PROVIDING ALL 517E AND SAFETY PROTECTION(FENCING,BARRIERS,ETC)DURING DESIGN OR CONSTRUCTION ERRORS. � ` ' - �= ' '� � ` �' � � 9-11-20 Issued for CONSTRUCTION IN ACCORDANCE WITH ALL APPLICABLE GODE5 AND ORDINANCES(OSHA,ETC)TO PROVIDE FOR THE SAFETY OF THE PUBLIC,AND THE / �' / ,;/ , / - PROTECTION OF THE SITE AND BUILDI'VG Y Filing IT SHALL BE THE RE5PON51BILITY OF THE GENERAL CONTRACTOR AND EACH OF HI5 SUBCONTRACTORS,TO V151T THE 51TE PRIOR TO 5UBM155ION OF HI5 BID NEW GYP. BD. / DROP CEILING. TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS, NO ADDITIONAL ALLOWANCES,OR EXTRA CHARGES,WILL BE PERMITTED BECAUSE OF HI5 FAILURE COMPLY WITH ALL CODES OF TO PERFORM THE AFOREMENTIONED 517E VISIT. NEW YORK STATE & TOWN CODES (DISCUSS W/ OWNER.) 4" MIN. LOPE GRA _ THE GENERAL CONTRACTOR SHALL NOTIFY THE AIR( IF ANY DISCREPANCY OCCURS BETWEEN ACTUAL FIELD CONDITIONS AND DRAWING5. THE LINE OF EXIST. WINDOW OPENING. SDE-► GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD PRIOR TO CONSTRUCTION. AS REQUIRED AND CONDITIONS OF Q DO NOT SCALE DRAWINGS.WRITTEN DIMENSIONS CONFIRMED BY FIELD CONDITIONS TAKE PRECEDENCE. IF DISCREPANCY ARISES BASED ON FIELD ANY ITEM OF WORK NECESSARY FOR PROPER COMPLETION OF CONSTRUCTION,WHICH 15 NOT SPECIFICALLY COVERED ON THE DRAWINGS OR IN THE WN LANNINU BOARD N CONDITIONS CONSULT WITH ARGHITEG'f'S OFFICE BEFORE PROCEEDING WITH WORK OR ORDERING MATERIALS. I_--- SCUTHOLaT T ENLARGE EX. WINDOW OPENING - ;_, NEN "BILGO - SGAPEWEL" or SPECIFICATIONS,SHALL BE CONSIDERED INCLUDED IN THIS WORK AND SHALL BE PERFORMED IN A MANNER DEEMED GOOD PRACTICE OF THE TRADE v` ' 1. ' -1--APPROVED EQUAL EGRE55 INVOLVED. T" ' T $ FOR NEW 2'5"x45' EXISTING 2 STORY - ;:,k. ,:_t, �=WINDOW WELL. CASEMENT WINDOW (EGRESS)THE GENERAL CONTRACTOR SHALL BE FRAME RESIDENCE TANKS AND UTILITIES,UNDERGROUN12 PIPIINNG OR STRULELY CTURESETHAT MAY INTERFERE W THA EW WORKCT IOR DEMOLITION AND TON OF ANY EXISTING DO PROTECT SAM�FOROM ANY S SFr "ANDERSEN - GXI45° or EQUAL. X ___-__..___._-___.-________ ,', x,==. .:' DAMAGE. THE REPAIR OF ANY DAMAGE DUE TO NEW CONSTRUCTION OR DEMOLITION 15 THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. w - - C '" r -i #145 THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL DEMOLITION,EXCAVATION,CARTING,REFUSE AND THE LEGAL DISPOSAL OF SAME AS -71 _ REQUIRED TO ALLOW FOR NEW CONSTRUCTION AND REMOVAL OF ALL DEBRIS FROM THE SITE. 3/4" GLEAN FREE DRAINING ROCK OCCUPANCY OR NEW 3-1/2" MTL. STUDS AT 16" 3.5" MIN. ;,rf J;:I=III- THE GENERAL CONTRACTOR 15 TO COORDINATE WITH THE OWNER FOR INSTALLATION OF THE OWNERS ALARM AND TELEPHONE 5YSTEM5 AND SHALL Q .a ° OR A6 STONE AT LEAST 12 O.G. W/ R-13 INSULATION -' cm COOPERATE WITH OWNER'S INDEPENDENT CONTRACTORS. THE GENERAL CONTRACTOR SHALL PROVIDE ADVANCED NOTICE TO THE OWNER A5 TO WHEN TO ' ISE IS I IN�/1 UNLAWFUL I I {r�-r s,- , ,, .a t y j r -, _III=AROUND 5IDE5 AND FILL TO SCHEDULE INSTALLATION 50 A5 NOT'f0 DELAY COMPLETION OF THE PROJECT. USE V V !l U L MIN. I/2" GYP. BD. INTERNALLY a ;'7 r DEPTH OF FOUND. FTG. DI5P05E OF ALL(IF ANY)HAZARDOUS MATERIAL OR ASBESTOS IN AN APPROVED MANNER AS REQUIRED BY FEDERAL,STATE AND LOCAL AGENCIES WITHOUT CERTIFICATE (MIN. AIR GAP TO GONG.) m (INCLUDING THE EPA). -r - + h Q _ � G=rj y •r-r-t ' '. . � �a.-�' III- �_ REMOVE AND REPLACE ANY AND ALL. DAMAGED,ROTTED OR OTHERWISE UNSOUND FRAMING. REPLACEMENT FRAMING MUST BOF OCCUPANCY NEW FINISHED FLOOR OF PROPER SIZE AND BEARING TO SUPPORT ANY AND ALL LOADS IMPOSED. TO BE SELECTED. _ - EXIST. FOUNDATION WALL THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR AND/OR REPLACEMENT OF ANY ITEM OF EXISTING CONSTRUCTION THAT 15 TO REMAIN OR �:cr�`�'sL?�,f)_t-�.�"'F -�'�- �----� , SLAB 8 THAT 15 DAMAGED DURING NEW CONSTRUCTION. FOOTING TO REMAIN. / . .; THE ARGHITEGT SHALL NOT BE RESPONSIBLE FOR THE PERFORMANCE OR THE WORK OF THE GENERAL CONTRACTOR,OWNER OR ANY OTHER HIGH LOW F.A.I. 0AL05. SUBCONTRACTORS NOR SHALL HE GUARANTEE THEIR PERFORMANCE. ,000 BTU OF HEATING EQUIPMEN BOILER. . . ... . . . BTU III THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR ANY CHANGES 70 THI5 PROJECT MADE BY OWNER,GENERAL CONTRACTOR OR ANY SUBCONTRACTOR OR FOR 145 (- MATERIAL SUPPLIER UNLESS PROPERLY AUTHORIZED,IN WRITING,BY THE ARGHITEGT. 50. IN. = 4,000 BTU --' - THE ARCHITECT SHALL NOT HAVE CONTROL OVER OR CHARGE OF AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS,METHODS,TECHNIQUES, (145,000 BTU/4,000 BTU)x 150. IN.= 36.25 -_� L_-I_,_I--1 %� -- I' 125.0 SEQUENCES OR PROCEDURES OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK SINGE THESE ARE SOLELY THE GENERAL REQUIRED: 31.0 50. IN. CONTRACTOR'S RESPONSIBILITY UNDER THE CONTRACT FOR CONSTRUCTION. THE ARCHITECT SHALL NOT 8E RESPONSIBLE FOR THE GENERAL CONTRACTOR'S PROVIDED: b' DUCT = 48 SQ. IN. E&RESS TAI L SCHEDULES OR FAILURE TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRARY DOCUMENTS. THE ARCHITECT SHALL NOT HAVE CONTROL OVER OR 48 SQ.IN.>45.0.0 SQ. IN.---THEREFORE O.K. O,L.D I L D COURT / CHARGE OF ACTS OR OMISSIONS OF THE GENERAL CONTRACTOR,SUBCONTRACTORS OR THEIR AGENTS OR EMPLOYEES,OR OF ANY OTHER PERSONS J� PERFORMING PORTIONS OF THE WORK.. THE GENERAL CONTRACTOR SHALL PROVIDE FOR ALL PROPER BRACING,5HEETPILING, SHORING,DE-WATERING,ETC.,AND THE PROTECTION AND SUPPORT OF THE EXISTING AND ADJACENT STRUCTURES AND TREES THAT ARE TO REMAIN.PROVIDE FOR ALL UNDERPINNING AS REQUIRED DUE TO FIELD AND PROJECT SCALE: 1/2114-0 1-011 CONDITIONS. 0� I I ti THE GENERAL CONTRACTOR SHALL CONFIRM AND VERIFY EXISTING BEARING CONDITIONS BEFORE PROCEEDING WITH THE WORK. L.1 GHT I VENT. GALLS. 01 F L 0 T PLAN ANY DAMAGE TO ANY EXISTING PAVEMENTS(INCLUDING PUBLIC STREETS)OR STRUCTURES TO REMAIN MUST BE REPAIRED TO THEIR ORIGINAL CONDITION OR REPLACED BY THE GENERAL CONTRACTOR AT NO EXTRA COST TO THE OWNER. FINISH CELLAR n ALL MATERIALS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND/OR INSTRUCTIONS. HABITABLE FLOOR AREA: 634 SOFT. ) I/ LIGHT IWC /per RESEGURE AND PROPERLY SUPPORT ALL EXISTING FRAMING AND ALL OTHER CONSTRUCTION THAT MAY BE AFFECTED BY NEW CONSTRUCTION. REQUIRED NATURAL PRIOR TO ORDERING WINDOWS,CONTRACTOR TO VERIFY ALL DOOR/WINDOW OPENINGS. LIGHT(890): . 634 x .OS = 50.12 5Q.FT. CONTRACTOR SHALL BE FULLY COVERED BY WORKMAN'S COMPENSATION INSURANCE AND SUCH INSURANCE AS MAY BE REQUIRED BY LOCAL LAW5. OR AS PER SECTION R303.1 EXCEPTION#2 NEW 50 CFM EXHAUST FAN "PANASONIC NEW 3-1/2"MTL.STUDS ATDTor- NEW HI /LOW 6"x8"FRESH ARTIFICIAL LIGHT CAN BE 5UB5TITUTED IF IT IS WHISPER"OR EQUAL VENTED TO R-13 BATT IN5ULATION $ M - - - - EXIST.WATER AIR DUCT AS PER N.Y.5. RES. GONTRAGTO¢5 SHALL GUARANTEE FOR A PERIOD OF ONE(1)YEAR FROM THE DATE OF FINAL COMPLETION,AND ACCEPTANCE BY THE OWNER,ALL WORK CAPABLE OF PROVIDING AN AVERAGE ILLUMINATION EXTERIOR AS PER MANUF.5PEG5 d INTERNALLY.(MIN. I" AIR GEXIST.C IL TANK. STORAGE TANK. BLDG.CODE. PERFORMED UNDER THEIR RESPECTIVE CONTRACTS. of 6 FOOT-CANDLES OVER THE AREA OF THE TO N.Y.S.CODE CONTRACTOR TO PROVIDE DETAILED PRICE BREAKDOWN.OWNER TO PROVIDE BUILDING PERMIT,SURVEY AND FINAL SURVEY. ROOM AT A HEIGHT OF 30"ABOVE THE FLOOR. T• z EXIST. PROVIDED: CONTRACTORS AT TIME OF COMPLETION OF WORK,WHERE APPLICABLE OBTAIN FIRE UNDERWRITERS CERTIFICATE FOR ELECTRICAL WORK AND BUILDING 6 FOOT(ANDLE5 OF ARTIFICIAL LIGHT PROVIDED. DEPARTMENT ACCEPTANCE AS MAY BE REQUIRED BY THEIR RESPECTIVE TRADES. (SEE FLOOR PLAN) E CONTRACTOR TO EXPEDITE THE WORK:AND ESTABL15H WITH THE OWNER A COMPLETION DATE. VENTILATION F t 30141 �}° I - ALL WORK L157EP ON THE CONSTRUCTION NOTE SHEETS AND 5HOiN OR IMPLIED ON ALL DRAWING5 SHALL BE SUPPLIED BY THE CONTRACTOR AH05E REQUIRED NATURAL F SPIELER BUILDING TRADE STATUS STANDARDLY REQUIRES SAME. VENTILATION(4%): 634 x .04 = 25.36 50.FT. EXISTING AIC UNIT.RELOCATE DURING THE COURSE OF CONSTRUCTION IF MODIFICATIONS TO THE DESIGN OCCUR AS A RESULT OF CLIENT,ARCHITI�07,ETC.THE CONTRACTOR SHALL SUBMIT OR A5 PER 5ECTION R303.1 EXCEPTION #1 AN IF REQ'D. TO AGGOMODATE ® ® ® ® R ES I D E N C E NEW EGRE55 WELL TWO WRITTEN COPIES OF A CHANGE ORDER WITH THE AMENDED PRICE. CONTRACTOR SHALL NOT CONTINUE WITH ANY GRANGES UNTIL HE RECEIVES WRITTEN - � -� -� APPROVED MECHANICAL VENTILATION SYSTEM �t � + EXIST.G.M.D. D.HARDWIRED AUTHORIZATION FROM THE OWNER. , �j -I -8 LL _ CAPABLE OF PRODUCING 0.35 AIR EXCHANGE - p O 'GLC. HT. CONTRACTOR TO RESTORE ANY PORTION OF HOUSE DAMAGED DURING ALTERATION. PER AN HOUR CAN BE SUB571TUTED FOR THE +� x _ NATURAL VENTILATION. O N � FIN.FLR.TO BE SEL./GYP.BD.WALL5/ ,ry,/,/,V/�'��� CMD x 5/8"GYP.BD. ­-EX157.OIL BOILER. 145 OLD FIELD COURT, SHALL UPON COMPLETION OF THEIR RESPECTIVE WORK REMOVE FROM THE PREMISES ALL DEBRIS,TOOLS,EXCESS MATERIALS AND Q X ® GYP.BD/DROP GLC.(DISCUSS w/OWNER) �1 C� 5D I I IN - CONTRACTORS ® "TYPE-X"ON GLG.� MATTITUCK NY 11952 [(634 S.F. x 1'q")/60 x 0.35 = 28.1 _ APPURTENANCES,AND LEAVE THE PREMISES INA"BROOM GLEAN"CONDITION. � ENLARGE EX.WINDOW OPENING AS R Q'D. w � w I � 28.1 CFM REQUIRED FOR NEIN 75"x4'5"CASEMENT WINDO I UNFINISH_D CELLAR THESE DRAWINGS ARE TO BE UTILIZED ONLY FOR THI5 PROJECT. THEIR USE FOR OTHER PROJECTS 15 PROHIBITED WITHOUT FIRST OBTAINING THE WRITTEN (E6RE55) "ANDERSEN -GXI45"or EQ AL. �Q, PERM155ION FROM THE ARCHITECT PROVIDED: O u ,EY,• �'_q" NEW "PANA50NIC-WHI5PER"50 CFM EXHAUST FAN - - ® 0 0 0 0 11 4I"GLC. HT. L - - OR EQUAL A-I -i I FINISHED CELLAR EXIST. ELEC. F , T II EX.(2) I-3/4"xl l-1/8"LVL_�- �' 4F� __ - - When a registered design `r professional has stamped and NEW "BILGO -SGAPEWEL"or APP.EQUAL o � � ____ signed this page (blue ink), ZONING GALGULAT I ON5 GENERAL INFORMATION �G�ND EGRESS WINDOW WELL A PER N.Y.S.CODE. INSTALL A5 PER MANUFACTURER SPECS. - - - - - - �- - - - - I they are attesting that to the IT- NOT APPLIGADLE. LOCATION: 145 OLD FIELD GT. MATTITUGK PORTION OF EXISTING I I5L PE W I I best of his/her knowledge, WALL TO BE REMOVED ®E ®E ®E GL OR. belief, and professional NEW FINISHED CELLAR. VILLAGE OF 50UTHOLD I I EXISTING WA5HER. judgement, such plans and/or NO CHANGE TO EXISTING S.F. 5E6: 120 BLOCK: 5 LOT: B.11 ZONE: AC PORTION OF EXISTING + �' . L- 1__1 specifications a re WALL TO REMAIN - GLC. HT. 6FINEW WALL/PARTITION N o FIN,FL . O13E SEL. in compliance with the latest New York State Building Code. (SEE PLAN FOR THICKNESS) w ® EXIST.GYP.BD.GLC.TO REMAIN ` EXISTING DRYER VENTED TO EXTERIOR. © COpyl copyright 2020 X � X NYS RE51 DF-NTI AL BUILDING GODS: NOTF-5: - - - - LINE of ABOVE I I OE OE OE 4 W I Q I w GMD SMOKE / CARBON MONOXIDE EW 36"HIGH OPEN . I SECTION R310: 'E:MERGENGY ESCAPE AND RESCUE OPENINGS' �SD DETECTOR UNIT I RAILING A5 PER N.Y.S. X CODE TO BE SELECTED. w BASEMENTS WITH HABITABLE SPACE AND EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE E C^ EMERGENCY ESCAPE AND RESCUE OPENING. SILL HEIGHT5 TO BE NOT MORE THAN 44" ABOVE FLOOR. EXHAUST FAN I I � � 11P ,, ,\; AS PER SECTION R310.2.1: 'MINIMUM OPENING AREA I I I ti� ALL EMERGENCY ESCAPE AND RESCUE OPENINGUNEXCAVATED S SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.1 S.F. SWITCH r EXCEPTION: 3 3-WAY SWITCH GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 S.F. ( ; SMOKE ALARMS $ CARBON MONOXIDE DETECTORS' 0 RECESSED LIGHT FIXTURE - AS PER R514 SMOKE DETECTORS TO BE INSTALLED IN ALL BEDROOMS,SLEEPING QUARTERS,ADJACENT I I I HALLWAYS,AND ON EACH HABITABLE FLOOR INCLUDING 5A5EMENTS/0ELLARS AND HABITABLE ATTICS - ALL CEILING MOUNTED LIGHT FIXTURE SMOKE DETECTORS TO BE HARDWIRED AND INTERCONNEGTED -VERIFY IN EXISTING ROOMS,REPLACE OR INSTALL AS NECESSARY AND AS REQUIRED. - AS PER R515 CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUT5IDE OF EACH SEPARATE SLEEPING AREA PULL CHAIN LIGHT FIXTURE I FILE: WITHIN 15 FT.OF THE BEDROOM5,WHERE FUEL-FIRED/BURNING APPLIANCES OR FIREPLACES ARE LOCATED . WITHIN A BEDROOM OR ITS ATTACHED BATHROOM IT SHALL BE INSTALLED WITH IN THE BEDROOM,AND WITH IN - - - - DWELLINGS WITH ATTACHED GARAGES OR FUEL-FIRED APPLIANCES - ALL CARBON MONOXIDE ALARMS SHALL DUPLEX OUTLET / GROUND FAULT SCALE: BE INTERCONNECTED -VERIFY IN EXISTING ROOMS, REPLACE OR INSTALL AS NECESSARY AND AS REQUIRED. GFI INTERRUPTER 5EG7ION 1351 L .ES: 'HANDRAILS' NOTES: AS NOTED HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH STAIRWAY w/FOUR OR MORE RISERS 8DRAWN BY: - RECEPTACLES SHOWN WITH 'E"- DENOTING EXISTING- TO BE CHECKED AND/OR I-I/2" OFF THE WALL. HANDRAIL HEIGHT SHALL NOT BE LESS THAN 34" AND NOT MORE THAN 38" HIGH. REWIRED TO WORK PROPERLY AS PER CODE- TVP. G�LLAR FLOOR ���� SM SECTION KILL-,!: 'HEADROOM' - ALL ELECTRIC RECEPTACLE5,5WITGHE5,OUTLETS,GABLE,TELEPHONE AND LIGHT THE MINIMUM HEADROOM IN ALL PARTS OF THE STAIRNAY SHALL NOT BE LE55 THAN 6-8" MEASURED VERTICALLY FIXTURES TO BE REVIEWED WITH OWNER d DE51ONER/ARCHITECT FOR SHEET: FROM THE SLOPED PLANE ADJOINING TO THE TREAD HOSING OR FROM THE FLOOR SURFACE OF THE LANDING OR LOCATION BEFORE ACTUAL PLACEMENT. SCALE: 1/4"=1'-O" PLATFORM -CONTRACTOR SHALL BLOCK OUT FOR ALL LIGHTING FIXTURES AS REQUIRED.