HomeMy WebLinkAbout45534-Z �o�p OF l'�CpG� Town of Southold 2/28/2021 P.O.Box 1179 0 * ` 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41853 Date: 2/28/2021 THIS CERTIFIES that the building GENERATOR Location of Property: 580 Terry Path, Mattituck SCTM#: 473889 Sec/Block/Lot: 123.-6-20 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/23/2020 pursuant to which Building Permit No. 45534 dated 12/4/2020 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessga generator as applied for. The certificate is issued to Whitrock,Kevin of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45534 12/4/2020 PLUMBERS CERTIFICATION DATED Authorized Signature r� TOWN OF SOUTHOLD ��o�g11FF0(,��oGy BUILDING DEPARTMENT TOWN CLERK'S OFFICE o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45534 Date: 12/4/2020 Permission is hereby granted to: Whitrock, Kevin 46 Willow Ridge Dr Smithtown, NY 11787 To: install generator as applied for. At premises located at: 580 Terry Path, Mattituck SCTM # 473889 Sec/Block/Lot# 123.-6-20 Pursuant to application dated 11/23/2020 and approved by the Building Inspector. To expire on 6/5/2022. Fees: ACCESSORY $100.00 ELECTRIC $85.00 CERTIFICATE OF CUPANCY $50.00 Total: $235.00 spector Town Hall Annex ~ ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 sean.deviin(a)_town.southold.n us Southold,NY 11971-0959 y' CU ,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To Kevin Whitrock Address: 580 Terry Path city Mattituck sr NY zip: 11952 Building Permit#: 45534 section: 123 Block: 6 Lot: 20 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Custom Lighting of Suffolk License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures Bath Exhaust Fan Seance 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceding Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment. 13.4kW Generator Kohler Notes " AS BUILT NO VISUAL DEFECTS Generator Inspector Signature: Date: December 4, 2020 S Devlin-Cert Electrical Compliance Form As 0.�o�gUfFOI/�coG TOWN OF SOUTHOLD—BUILDING DEPARTMENT Town Hall Annex 54375 Main Road P. O. Box 1179 Southold,NY 11971-0959 Telephone(631)765-1802 Fax (631)765-9502 https://www.southoldtgLAM.gov Date Received APPLICAMN FOR BUILDING PERMIT Fjor Office Use Only PERMIT NO. Building Inspector: ? NOV 2 3 2020 �r Applications and forms must be filled out in•their entirety.-Incomplete '=applications will not,be aecepted. Where the'Applicant is not`the owner,an° Owner's Authorization Pa form o ( ge,2)shall,be,completed: Date: %IILAIAC) OWNERS)OF PROPERTY,: ,r. Name: SCTM#l000- P.93 Physical Address: -7..Q_ j�, Phone#: 'Ll q00 Email: Mailing Address: 0�,� )rim n�a CQNTACT PERSON: Name: KA l Mailing Address-y -, � 39 �j1TvC� s�,._ Vin Phone#: �P } ®"7 ¢1�fl Email: aADS,MPri^� DESIGN'PROFESSIONAC INFORMATION: Nam-- 1- 1 .,;\"��. Mailing Address: -1 1: ��k '5+,-cI �k _ WiA A. ._ ..,µ.. . �.Sk _r Phone#: 'CONTRACTORINFORMATION: �"_ _•'` _ - . _ ' _ ' _ Q \ Mailing Address: , Phone#: Li bD Email: Asn®Syvor) DESCRIPTION'OF�PROPOSED CONSTRUCTION' ❑New Structure ❑Addition ❑Alteration ❑Repair ❑Demolition Estimated Cost of Project: Other gQne.lti�br $ y y X000 Will the lot be re-graded? ❑Yes�AO Will excess fill be removed from premises? ❑Yes VNo 1 -} - PROPERTY,INFORMATION; Existing use of property: Intended use of property: ji,� � �� ►�e5���n���� Zone or use district in which premises is situated: Are there any covenants and restrictions with respect to r'.. w. .. this property? ❑Yes A o IF YES, PROVIDE A COPY. 19 Check Bokt Afier'Readigig:-'The owner/contractoridesign--prdfessiohal is responsible for all drainage and storm wateelssu'esl provided by" Chapter 236 of the TOW6*code. APPLICATION IS HEREBY,MADE to the Building,Department for the�issuance of�a Building Permit pursuant to the Building Zone, Ordinance of the Town of southo6"Suffolk,County;Ne,Woork and other a0piIcable Laws;Ordinances or Regulations,for the constructbuildings,, ,additions,alteraiions br_for enioval or�dernolition as herein described.=The applicant agrees to coriiply wiih`all,'applicable lavas,ordinances;building code,`";, „housing code and regulations and'to admit authorized,Inspectors on premises and in buildings)for necessary inspections.False statements made herein are._ punishabl 'as a Class'A misdemeanor pursuant to Section 210A5 of the NewYork State Penal- Application enal Application Submitted By(print name):V% 'SZ r r%A �✓ytps� N��f ��Authorized Agent ❑Owner Signature of Applicant: Date:____ I� STATE OF NEW YORK) SS: CO U NTY O F 1-4oV, ) MA(-I 1-rnn (-\c being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)he is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his/her knowledge and belief;and that the work will be performed in the manner set forth in the application file therewith. Sworn before me this Y.L 2 J day of N0y.r a-- , 20_0,10 Notary Public TRACEY L. DWYER NOTARY PUBLIC,STATE OF NEW YORK P°R®PER7V OWNER AMORMA70M NO.01 DW6306900 (Where the applicant is not the owner) QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30.292—A `� � 7 1, y Qyi n Wy` Cbcy-- residing at �� l�rLj 0� do hereby authorize M01] I "MDS M&iW to apply on my behalf to the TowMfhold Building Department for approval as described herein. kA-2-1 Owner's Signature Date Print Owner's Name 2 i Glenn Goldsmith,President �rjf SOUry Town Hall Annex Michael J.Domino,Vice-President �Q� ��� 54375 Route 25 P.O.Box 1179 John M.Bredemeyer III l�L Southold,New York 11971 A.Nicholas Krupski G Q Telephone(631)765-1892 Greg Williams %2� �� Fax(631) 765-6641 BOARD OF TOWN TRUSTEES DOT TOWN OF SOUTHOLD rrqv �yrp BU D IG DEPTE CERTIFICATE OF COMPLIANCE >'1`;O3i 'aty�)'d'BOli1� 1728C Date:July,15,2020 THIS CERTIFIES that the demolition of an existing 889sq.ft.one-story dwelling,210sq.ft.detached garage,and abandon existing septic system:construct a 1,442sq.ft.two-story dwelling with a proposed at grade 6'x28'(168sq.ft.)deck against the landward edge of the bulkhead;a proposed 576sq.ft.detached garage;install a new septic system 120' from wetland boundary;and to install two(2)6'x5' drywells to contain roof runoff on the dwelling,and one(1)6'k5' daRell to contain roof runoff on the new detached garage;with the condition that if issues arise with the Building Department relative to the deck,applicant must amend the permit;as built 2'x8' second-story cantilever over existing as-built 5'x10'wood steps;as-built 5'x7' entry stoop,5'x10'wood steps, in replacement of existing concrete walkway:as-built 16'x20' on-grade paver patio;construct 20.2'x24.3' one-story framed garage,in lieu of previously approved 24'x24' garage;installation of two(2)6'x4' daRells in lieu of previously approved two(2)6'x5'dcywells;as-built 4'x7'platform supporting two air-conditioning units;as-built 4'x6' outdoor shower on landward side of house:as-built 3'x4' 9enerator pad;and for the 83' long stone wall landward of the:existing dwelling= At 580 Terry Path,Mattituck Suffolk;,County Tax Map#1000-123-6-20 Conforms to the application'for a Trustees Permit heretofore filed in this office Dated May_11,2018 pursuant to which Trustees Wetland Permit#9263 Dated June 20,2018,was issued and Amended on July 15,2020 and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is demolition of an existing 889sq.ft. one-story dwelling, 210sq ft detached garage and abandon existing septic system,• construct a 1 442sq ft two-story dwellin with ith a proposed at grade 6'x28' (168sq ft)deck against the landward edge of the bulkhead;a proposed 576sa.ft.detached garage;install a new septic system 120' from wetland boundar;and to install two(2)6'x5' drywells to contain roof runoff on the dwelling and one(1)6'x5' drywell to contain roof runoff on'the new detached garage;with the condition that if issues arise with the Building Department relative to the deck applicant must amend the permit; as- built 2'x8' second-story cantilever over existing as-built 5'x10'wood steps•as-built 5'x7' entry stoop,5'x10'wood steps in replacement of existing concrete walkway• as-built 16'x20' on-grade paver patio;construct 20.2'x24.3' one-sto1y framed garage in lieu of previously approved 24'x24' garage,• installation of two(2)6'x4' dDaells in lieu of previously approved two(2)6'x5' dnmells• as-built 4'x7'platform supporting two air-conditioning units;as- built 4'x6' outdoor shower on landward side of house,•as-built 3'x4'generator pad,•and for the 83' long stone wall landward of the existing dwelling. The certificate is issue o Kevin Whitrock owder of the aforesaid property. Authorized Signature r � 3 0 2020 BUILDING DEPARTMENT-Electrical Inspector , G TOWN OF SOUTHOLD ' r D ' �o n Hall Annex- 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 Arogerrasoutholdtownny-aov- seand(aD-southoldtownny.g-ov, APRUCAT10N FOR ELECTRICAL INSPECTION. I ELECTRICIAN INFORMATION (All Information Required) Dates 10 IQ 2.p Company Name: Name: VbrDS)C.\ License No.: IME email: Address: Phone No.: — c JOB SITE INFORMATION (All Information Required) n Name: _ c,v i Address: 45- X(? c, _ Cross Street: Phone No.: Bldg.Permit#: email: Tax Map District:.,'- 1000T Sectorif g Block: Lot:,,Pn1 BRIEF DESCRIPTION OF WORK (Please Print Clearly) t Circle All That Apply: gPe Svc ce 'Oe,{-el F Is job ready for inspection?: ES / O Rough In Final ; ii Do you need a Temp Certificate?: ES I/N Issued On _ vv ., Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters _ Old Meter#, New Service- Fire Reconnect- Flood Reconnect-Service Reconnected - Underground -Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Informatiori, � E,e�o2 /�/� PAYMENT DUE WITH APPLICATION ' Request for Inspection Formals AIV OS MERINGER BUILDER Amos H.Meringer P.O.Box 315 la Mattituck,NY 11952 (631)513-6283-C (631)765-4900-0 (631)765-4999-F AmosMeringer@yahoo.co To Whom It May Concern: Attached is the electrical form for Generator at the Whitrock Residence, building permit number 43236. Any further questions please call at 631-765-4900. Molly 00 SHEO 11.1' FRAME J o U/G ny I PROPANE i' 3-1 TANK 70 — 11.6 v c t 3 , ;- CB I CONCRETE - i g,8' DRAIN ,. 20.2 1 TIMBER CURB sv.S-W 1.1' GF-9.7 12-.4 , - -� . TIMBER -00gER CURB"O.L. �ELEC. CURB 1' METER GEN. w' PAD m LOW W�CONC. c' 2 STY. G ° - °.G4 ' e FR. HSE G3 ° , ° G1 ° 9 G2 t ° 0 1 Z 0.8 E m METAL I 0.4W COVER ST Z TEST HOLE' pP` v rn EL9.1' Poo � o cK o " S WER`�, CONC. WALL B; ,17.7' •A•N WOOD STEPS OYE ,AC UNITS ON PLAT (n rx 0 � w 50' 2ND STY. CANTILEVER r�*I �N�' , OVER WOOD'STEPS p tOT i. > p"IlE 27.9' RET W� i t FE►'1 IIIA R WALL 1.1E AMBER LINED a y slo%E PATIO 1'W. FEB ,8 ' 2 6 2020 Buu01EAD +as 0.2E DECK 4}$ WOOD tr�Ct, }R'1St MAI ' 1.5+ _ NEW FR• �� �.9 0' r'� :_. ,. •li.. _t. ?�.��' FN ZONE X Bum s + ZONE X ISH . n� ALONG Itij 1' =NE D 20NE LINE— .F N81*46'22'58 --- �- zON .58 �aF HEVV,xo. ORWAT YRCONIC LIC.' N0: 49e fr0. PECONIC „ ' P.C. 22,775 SO. Fr. P.O. 765-5020 FAX (631) 765-179 P.O. BOX 909 TIE LINES 1230 TRAVELER STREET, �2--30; SOUTHOL'D, N:Y. , ' APPROVED AS NOTED DATE: . B.P.# FEE: SII/2J BY: NOTIFY BUILDING DEPARTMENT AT 765-1802 8 FOLLOWINGAINSPEOCTIONS:FOR THE OCCUPANCY OR '. FOUNDATION -FOR POURED CONCRETE QUIRED USE IS UNLAWFUL 2. ROUGH = FRAMING & PLUMBING 3. INSULATION WITHOUT CERTIFICATE 4. FINAL - CONSTRUCTION MUST OF OCCUPANCY BE COMPLETE Fv);: O ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES ELECTRICAL AS REQUIRED AND CONDITIONS OF INSPECTION REQUIRED X01 fTHOLC TOWN RA OARD ''-G-lFr3V'NiR6 TEES r KOHLER, Models:.20RCA(L) Multi-Fuel LPG/Natural Gas 9001 standard Features LA KOHLER. • RDC2 Controller NATIONALLY REGISTERED o One digital controller manages both the generator set and transfer switch functions(with optional Model RXT). o Electronic speed control responds quickly to varying •7 i demand. o OnCueO Plus Generator Management System for remote monitoring is included with the generator. '� -r: ` • • Kohler Command PRO Engine Features o Kohler Command PRO®OHV engine with hydraulic valve u ± lifters for reliable performance without routine valve adjustment or lengthy break-in requirements. ' • Designed for Easy Installation KMLk o Sturdy aluminum base can be mounted on gravel or a ` concrete mounting pad. o Fuel and electrical connections through the enclosure wall The Kohler® Advantage eliminate the need for stub-ups through the base. o Customer connection terminal block located near the • High duality Power controller allows easy access for field wiring. Kohler home generators provide advanced voltage and o Designed for outdoor installation only frequency regulation along with ultra-low levels of • Certifications harmonic distortion for excellent generator power quality to protect your valuable electronics. o Meets emission regulations for U.S. Environmental Protection Agency(EPA)with both natural gas and LPG. • Extraordinary Reliability o UL2200/cUL listed (60 Hz model). Kohler is known for extraordinary reliability and o CSA certification available(60 Hz model). performance and backs that up with a premium 5-year or o Accepted by the Massachusetts Board of Registration of 2000 hour limited warranty. Plumbers and Gas Fitters. • Powerful Performance o Meets 181 mph wind rating. Exclusive Pow§boost- technology provides excellent starting power. Approved for stationary standby applications in locations served by a reliable utility source. • Aluminum Enclosure • 20RCAL models packaged with a Model RXT automatic o Attractive aluminum enclosure allows installation as transfer switch are available. See page 4 and the Model close as 18 inches from your home or small business. RXT ATS specification sheet. o Enclosure panels can be removed without tools to allow easy access for maintenance and service. • Warranty o 5-year/2000 hour limited warranty for on-grid (standby) applications in locations served by a reliable utility source. Generator Ratings Standby Ratings Line Circuit Natural Gas LPG Breaker Alternator Voltage Phase Hz kW/kVA Amps kW/kVA Amps Amps Poles 2F7 120/240 1 60 18/18 75 20/20 83 100_ 2 120/208 3 60 17/21 58 17/21 58 70 3 2G7 120/240 3 60 17/21 51 17/21 51 60 3 277/480 3 60 17/21 26 17/21 26 30 3 Note: The line circuit breaker is automatically selected based on the generator set model and voltage configuration. RATINGS Standby ratings applyto Installations served by a reliable utility source.All single-phase units are rated att.0powerfactor The standby rating is applicable tovariable loads with anaverage load factor of 80%for the duration of the power outage No overload capacity Is specified at this rating. Ratings are In accordance with ISO-3046/1,535514,AS2789,and DIN 6271.GENERAL GUIDELINES FOR DERATING-ALTITUDE*Derate4%per305m(1000ft.)elevation above 153m(500ft.) TEMPERATURE.,Derate 2%per 55°C(10°F)temperature increase above 16'C(60°F). Availability Is subject tochangewlthoutnotice.The generator set manufacturer reserves the rightto changethe design or specificationswithout notice and without any obligation or liabilitywhatsoover Contact your local Kohler Cc generator distributor for availability. § Check the appliance manufacturer's specifications for actual power requirements.Consult a Kohlerm Power Systems professional to calculate your exact residential power system requirements t Meets NFPA guidelines for 18 Inch clearance to combustible materials. Check state and local codes for minimum distance required from a structure G4-272(20RCA) 9/19c Alternator Specifications _ Alternator Specifications Alternator Features Specifications Alternator . Compliance with NEMA, IEEE,and ANSI standards for Manufacturer Kohler temperature rise. Type 2-Pole,Rotating Feld ."Self-ventilated and dripproof construction. Leads,quantity - 2177 4 • Windings are vacuum-impregnated with epoxy varnish for 2G7 12 dependability and long life. Voltage regulator Digital • Superior voltage waveform and minimum harmonic Insulation: NEMA MG1 .66 distortion from skewed alternator construction. Material Class H • Digital voltage regulator with t1.0%no-load to full-load Temperature rise 130°C Standby RMS regulation. Bearing:quantity,type 1,Sealed • Rotating-field alternator with static exciter for excellent Coupling Direct load response. Amortisseur windings Full • Total harmonic distortion (THD)from no load to full load with Voltage regulation,no-load to full-load RMS -}1.0% a linear load is less than 5%. One-step load acceptance 100%of Rating Peak motor starting kVA: (35%dip for voltages below) 240 V, 1 ph 2F7(4 lead) 41 (60 Hz) 240 or 480 V,3 ph 2G7(12 lead) 69(60 Hz) Application Data Engine Exhaust Engine Specifications Exhaust System Manufacturer Kohler Exhaust temperature exiting the Engine:model,type CH1000 4-Cycle enclosure at rated kW,dry, °C(°F) 260(500) Cylinder arrangement V-2 Lubrication Displacement,cm3(cu.in.) 999(61) Bore and stroke,mm(in.) 90 x 78.5(3.54 x 3.1) Lubricating System Compression ratio 8,8:1 ' Type Full Pressure Main bearings:quantity,type 2,Heavy-Duty Sleeve Oil capacity(with filter),L(qt.)§ 1.9(2.0) Bearings Oil filter:quantity,type§ 1,Cartridge Rated RPM Oil cooler Integral 60 Hz 3600 § Kohler recommends the use of Kohler Genuine oil and filters. Max.engine power at rated rpm,kW(HP) LPG,60 Hz 23.0(30.9) Fuel Pipe Size Natural gas,60 Hz 20.2(27.1) Minimum Gas Pipe Size Recommendation,in.NPT Cylinder head material Aluminum Valve material Steel/Stellite® Pipe Length, Natural Gas LPG (ft.) Piston type and material Aluminum Alloy m 281,000 Btu/hr. 340,000 Btu/hr. 8 (25) 1 3/4 Crankshaft material Heat Treated, Ductile Iron Governor:type Electronic 15 (50) 1 1 Frequency regulation,no load to full load Isochronous 30 (100) 1 1/4 1 Frequency regulation,steady state ±0.5% 46 (150) 1 1/4 1 1/4 Air cleaner type Dry 61 (200)" 1 1/4 1 1/4 Engine Electrical Engine Electrical System Ignition system Electronic, Capacitive Discharge Starter motor rated voltage(DC) 12 Battery(purchased separately): Ground Negative Volts(DC) 12 Battery quantity 1 Recommended cold cranking amps: (CCA)rating for-18°C(0°F) 500 Group size 51 64-272 (20RCA) 9/190 KOHLER CO.,Kohler,Wisconsin 53044 USA KOHLER, Phone 920-457-4441,ales Fax 920-459-1646 For the nearest sales and service outlef in the US and Canada,phone 1-800-544-2444.' KOHLERPower.com Generator Set Standard Features Automatic Transfer Switches and Accessories • Battery Cables ❑ Model RDT ATS • EPA certified fuel system ❑ Model RXT ATS • Aluminum sound enclosure ❑ Model RXT ATS with combined interface/load • Critical silencer management board • Field-connection terminal block ❑ Load shed kit for RXT or RDT ❑ Power relay modules (use up to 4 relay modules for • Fuel solenoid valve and secondary regulator each load management device) • Line circuit breaker ❑ Other Kohler®ATS • Multi-fuel system, LPG/natural gas,field-convertible 20RCAL Model Packages • Oil drain extension with shutoff valve ❑ 20RCAL with 100 amp RXT with 16-space load center and • OnCue®Plus Generator Management System NEMA 1 steel enclosure for indoor installation 4 Premium 5-year limited warranty ❑ 20ROAL with 200 amp service entrance-rated Model RXT • RDC2 generator set/ATS controller with combined interface/load management board and • Rodent-resistant construction corrosion-resistant NEMA 313"aluminum enclosure - - • Sound-deadening,flame-retardant foam per UL94, Warranty class HF-1 ' ❑ 5-Year'Comprehensive Limited Warranty Available Options ❑ 107Year Comprehensive Limited Warranty Approvals and Listings ❑ CSA approval - Concrete Mounting Pads ❑ Concrete mounting pad,3 in.thick ; ❑ Concrete mounting pad, 4 in.thick (recommended for storm-prone areas) Electrical Accessories ❑ Battery ; ❑ Battery heater, 120VAC ❑ Battery heater,240VAC ❑,Cold weather package,120VAC Generator Set Dimensions and Weights ❑ Cold weather package,240VAC - _ Generator Set Size;L'x W'x H: 1193 x 666 x817 mm ❑ Emergency stop kit (47 x 26.2 x 32.2 in.) L] PowerSync®Automatic Paralleling Module(APM) _ , (single phase only;parallel two 20kW residential generator Shipping Weights: sets with the RDC2 controller) 20ROA Generator Set: 252 kg(555 Ib.) 20ROAL with 160 A RX-f ATS 277 Ll Programmable interface module(PIM) 20RCALwith 200 A RXT SE ATS:C 272 kg(61001 lb.) (provides 2 digital inputs and 6 relay outputs) r L Fuel System Accessories, ❑ Flexible fuel line(included on QS models) ❑ Carburetor heater, 120 VAC ® ❑ Carburetor heater,240 VAC H ®. Carburetor heater is recommended for reliable starting at temperatures below'0°C(32°F) Literature 49MM ❑ General maintenance literature kit W-.� ❑ Overhaul literature kit ❑ NOTE Dimensions are provided for reference only and should not be used for planning Production literature kit Installation Contact your local distributor for more detailed Information Maintenance DISTRIBUTED BY: , - ❑ Maintenance kit (includes air filter,oil,oil filter,and spark plugs) @2018,2019 by Kohler Cc All rights reserved. 64272 (20RCA) 9/19c Fuel Requirements RDC2 Controller Features, Continued' Fuel System • LED indicators for utility power and generator set source Fuel types Natural Gas or LPG availability and ATS position (Model RXT transfer switch Fuel supply inlet 1/2 NPT required) Fuel supply pressure,kPa(in.H2O): • LCD display: Natural gas 0.9-2.7(3.5-11) o Two lines x 16 characters per line LP 1.7-2.7(7-11) o Backlit display with adjustable contrast for excellent visibility in all lighting conditions Fuel Composition Limits* Nat.Gas LPG • Scrolling system status display: Methane,%by volume(minimum) 90 min. - o Generator set status Ethane,%by volume(maximum) 4.0 max. - o Voltage and frequency Propane,%by volume 1.0 max. 85 min. o Engine temperature Propene,%by volume(maximum) 0.1 max. 5.0 max. o Oil pressure C4 and higher,%by volume 0.3 max. 2.5 max. o Battery voltage Sulfur,ppm mass(maximum) 25 max• g o Engine runtime hours Lower heating value, MJ/m3(Btu/ft3),(minimum) 33.2(890) 84.2(2260) • Date and time displays * Contact your local distributor for suitability and rating derates based • Smart engine cooldown senses engine temperature on fuel compositions outside these limas. • Digital isochronous governor maintains steady-state speed at all loads - Operation Requirements • Digital voltage regulation: ±1.0%RMS no-load to full-load Fuel Consumption,m3/hr.(cfh)@ 60Hz • Automatic start with programmed cranking cycle %Load Natural Gas LPG • Programmable exerciser can be set to start automatically on 100 8.0 (281) 3.9 (136)' any future day and time, and run every week or every two 75 6.9 (243) 3.1 (109) weeks 50 4.6 (161) 2.3 (82) • Exercise modes: 25 3.6 (127) 1.7 (59) o Unloaded weekly exercise with complete system Exercise 2.0 (71) 1.0 (35) diagnostics Nominal fuel rating: Natural gas: 37 MJ/m3(1000 Btu/ft.3) o Unloaded full-speed exercise LPG: 93 MJ/m3(2500 Btu/ft.3) o Loaded full-speed exercise (Model RXT ATS required) LPG conversion factors: 8.58 ft.3=1 Ib. • Front-access mini USB connector for SiteTech'' or USB 0.535 m3=1 kg Utility connection 36.39 ft.3 =1 gal. • Integral Ethernet connector for Kohler®OnCue®Plus Generator Set Sound Data • Built-in 2.5 amp battery charger • Remote two-wire start/stop capability for optional connection Model 20RCA 8 point logarithmic average sound levels are of a Model RDT transfer switch 64 dB(A)during weekly engine exercise and 69 dB(A)during • Diagnostic messages: Displays diagnostic messages for the full-speed generator diagnostics and normal operation.* engine, generator, Model RXT transfer switch, programmable All sound levels are measured at 7 meters with no load. interface module (PIM), and load management device. * Lowest of 8 points measured around the generator. Sound levels at • Maintenance reminders other points around generator may vary depending on-installation • System settings: parameters. o System voltage,frequency,and phase RDC2 Controller o Voltage adjustment o Measurement system, English or metric • ATS status (Model RXT ATS required): o Source availability wttaea zwv o ATS position (normal/utility or emergency/generator) Req 600Hz o Source voltage and frequency ® ® ® ® ATS control (Model RXT ATS required): o Source voltage and frequency settings ® "" o Engine start time delay o Transfer time delays o Voltage calibration The RDC2 controller provides integrated control for the o Fixed pickup and dropout settings generator set, Kohler® Model RXT transfer switch, • Programmable Interface Module (PIM)status displays: s programmable interface module(PIM), and load shed kit. o Input status (active/inactive) o Output status(active/inactive) RDC2 Controller Features • Load control menus: • Membrane keypad: o Load status o OFF,AUTO, and RUN pushbuttons o Test function o Select and arrow buttons for access to system configuration and adjustment menus • LED indicators for OFF,AUTO, and RUN modes G4-272 (20RCA) 9/10c