HomeMy WebLinkAbout45812-Z EXISTING LIVING ROOM - NO C14ANGF.S
i
EXIST 5"x5" STEEL COL ON 16"x16" CONC PIER W/ 4-#4 REBAR VERT
24"x24"x10" CONC. FTG W/ #5 REBAR @ 6"OC - NO CHANGES —
LINE OF 2ND FL. BALCONY ABOVE - NO CHANGES
LOWER EXIST. FENCE TO 30" TALL
ADD PAVERS OR
CONC SLAB TO
THIS AREA - LEVEL_
I
EXIST. CELLJR STAIR - 140 CHANZIES W/ TOP OF STAIR
DOWN FOUNDATION
,
DD AN RAI - TO C DEJ R,8
NEW 8'-0"xSLID. WINDOW -1-3/4"x11-1/2"
2- 1-3/4"x1l1-1l-1/2" LVL HEADER U)
LVL HEADER TYP, Q
Lt
w
w
x
a w _ > !! w
z U w I
U- 2 F T
/ (n 0 F
x z �
w
r NEW 2X8 FRAMED WALL W/ R-.30 BATT INSUL
SIDING TO MATCH AT EXT.
1/2" GYP BD @ INT.
�REMOVEDOW-� EXIST. 1X6 CEDAR T&G @ CEILING &
CEILING/2ND FL FRAMING TO REMAIN
C) O� —
QQi��'<' i EXISTING 2ND FL FRAMING ABOVE IS `
�i 2X10 @ 16" OC W/ R-30 INSULATION
_ -
-
- w --
0 OPEN TO OFFICE NOTE: NEW FINISHED FLOOR @ OFFICE TO a I
0 ALIGN W/ EXIST FINISHED FLOOR @ ENTRY
0 SET TOP OF NEW FOUNDATION ACCORDINGLY
O
F-
wcnn
z I i C7
- o
EXIST DINING ROOM w r r�
r' w
%
�+ iv 8'-0"x5'-0" SLID. WINDOW ° o
2- 1-3/4"x11-1/2" LVL HEADER
LF- - - - - -
NEW 8" WALL TO ALIGN W/ EXIST ROOF OVERHANG
riN NEW ENTRY DECK
_ EXIST. SLID GL DOOR _ 5/4 X 6 CEDAR DECKING
-- - - - - - - BENCH - - __ -- ---
Z --
0O = 2
CO PLANTER I
N
w T� --
CJ __— ---
117
EXIST DECK
NOTE 12 7
REVISIONS
REVISED 12 . 7 . 20
; REVI ',
a
a AS PER INSTRUCTIONS FROM
SOUTHOLD BLD DEPT. PROPOSED FLOOR_PLAN
1. DOOR BETWEEN ENTRY &
w EXIST. DIN RM HAS-BEEN 1/4" = l'-O" 12.8.17
REMOVED
2. EXISTING 2ND FLOOR
ABOVE OFFICE AREA IS
NOTED AS 2X10 JOISTS W/
R-30 INSULATION
ROOT RESIDENCE
, 6315 INDIAN NECK LANE P r
PECONIC N.Y.
SCTM# 1000-86-06-20 d 4,wM,
ZONE R-40 1 79 ACRES
77006
REVISED 10 . 11 . 2 2
old ROOT RESIDENCE << �
6315 INDIAN NECK LANE
PECONIC N .Y.
G ' v20 EXISTING: SINGLE FAMILY RESIDENCE
--= SCTM# 1000-86-06-20
ZONE R-40 1 .79 ACRES
EXISTING LIVING ROOM - NO CHANGES EXISTING LIVING ROOM - NO CHANGES
PROPOSED:
ENCLOSE EXISTING CARPORT (WITH EXIST. 2ND
EXIST. 5"x5" STEEL COL. ON 16"x16" CONC. PIER W/ 4-#4 REBAR VERT. EXIST. 5"x5" STEEL COL. ON 16"06" CONC. PIER W/ 4-#4 REBAR VERT.
24N24 x10" CONC. FTG. W/ #5 REBAR @ 6"OC 24"x24"00" CONC. FTG. W/ #5 REBAR @ 6"DC - NO CHANGES I FL. OVER ) TO CREATE NEW HOME OFFICE SPACE
EXIST. WOODEN HALF WALL LINE OF 2ND FL. BALCONY ABOVE - NO CHANGES - - EXIST. POUR. CONC. WALL & FTG. NO CHANGES
EXIST. WOODEN
LVL UNDER BALCONY ABOVE LOWER EXIST. FENCE TO 30" TALL - - - - - - - -- - - - - - - - - - - - - - _ ATTACHED TO EXIST. SINGLE FAMILYRESIDENCE.
- _ _� - -� _ EXTEND EXISTING ENTRY AND ADD NEW STOOP
ADD PAVERS I I _ - -_ _rO
0 1ICONC. SLAB T ULTHIS AREA - EL-
- EXI T. ELL R S AIR - 10 HAN ES EXI T. ELL R S AIR - HANaES
m 1--- 1 W/ TOP OF STAIR
EX ST. OI J . S EPS TO CELLAR i 1 1 LU
LJ
D WN I FOUNDATION 1 I I D WN
_ I
X
W
LU Q I I > TABLE R301.514INIMUM UNIFORMLY DISTRIBUTED LIVE LOADS(in pounds per square foot)
a @ I i m DD AN RAI - O C DE - - - - _ LLU - - - - - - - - - - - - - - � Q
M
°
O I `�
W w
LIVE
I a 1"
N n
7777V EXIST POUR. CONC. ALL & FTG. - NO CHANGES I 0UrSE LUAU
3650 APW 5050 ACW 3650 I n (-
EXIST. WOODEN HALF WALL Ua I 1 I ( I I v ° Attics with limited storageg•tl 20
2- 1-3/4"x11-1/2" LVL HEADER
- - - - - - - I I NEW 8" MASONRY F UNDATION WALL ON 16"x8" °Z b
EXIST. 3-1-3/4"x11-7/8" LVL UNDER WALL ABOVE w U I I I I Attics without storage 10
I 1 E O NEW 12,000 BTU 230 VOLT 21.5 SEER I POURED CONC. FTG. I I
co w DUCTLESS MINI SPLIT AC W/ HEATER I w J� I 1 - w U Decicse 40
W I z@ Q O cn MODEL # O-ES-I2-HP-230E I I < "' �� I I .
° a WLU
a 1 1 U Exterior balconies 60
EXIST. FL. JOISTS ABOVE w l U m Q w / I �_ I I I p Fire escapes 40
n EXISTING 2ND FL. FRAMING ABOVE IS
2-1-3/4"x9-1/2" LVL @ 16" OC °o I ° w LL = 2X10 @ 16" OC W/ R-30 INSULATION " j d i
_ I 1 Guardrails and handralis 200
J I X Ln Ln co 0 EXIST. 1X6 CEDAR T&G @ CEILING & I I w I I I it uardralls in-fill componentsf 50'
� U I I ~ CEILING/2ND FL. FRAMING TO REMAIN I 1
X U_ O � w
UJ NEW 2X8 FRAMED WALL W/ R-30 BATT INSUL. I I Passenger vehicle garages' 5Qa
EXISTING COVERED CARPORT X I I J SIDING TO MATCH AT EXT. I 1 I I ( I I °
Rooms other than sleeping 40
O 1/2" GYP. BD. @ INT. L� I _ I I OJ
1 - - rooms
UJ o �� w a o I w Sleeping rooms 30
XII ° - -� I Q o ? 1 o fairs 40c
I
W I x o Z I X IDI I =N U
Lo
X P�° ° U) i I I I Q ° X 11 GENERAL NOTES
1° N �/C OPEN TO OFFICE
O+5 1 1 w N /�� DN 4 RI ER I 1 U I I)I T o - x 1
' I PLATFORM @ M X' = I I lm N o x W N 1. All work shall conform to the requirements of the 2020 Residental Code of NY
° 1 I J ° N State, County and Town Department Regulations, Utility Company requirements and
EXIST. 3-1-3/4"x11-7/8" LVL UNDER WALL ABOVE i 1 I I Oz I I ISI I best trade practises.
EXIST. �- - - - - - - - - - - - - - :PI to 4 r :P2. Before commencing work the Contractor shall file all documents required by the
MUDRM. Z - -� I I iQl I �'' 1 Building Department, pay all fees required by local agencies and obtain all required
06 uI 2X10 FLOOR JOISTS @ 16" OC permits.
oI I 1 I of I I 3. The Contractor shall visit the site and verify all dimensions and the existing
> 1 I 3 I Iw I I conditions affecting the work prior to construction. Any discrepancies which would
° dI I IJI �I 1 ;. I interfere with the satisfactory completetion of the work described herein shall be
@ � I I Z
C) I I o 8_g 1 g'-g4" reported to the architect or property owner. Do not start work until such conditions
o.• N NEW 8"
i MASONRY FOUNDATION WALL ON 16"x8"
I have been examined and a course of action mutually agreed upon. Failure to notify
i
F+ +s ° I EXIST. DINING ROOM g I O ( 1 1 POURED CON FTG. the owner or architect of unsatisfactoryconditions will be construed as an acceptance
EXIST. DINING ROOM a l p
CABINETS I 1 L - - _ - - _ - - - - - - - - _ - - I of the conditions to properly perform the required work.
UJ 0 2- 1-3/4"x11-1/2" LVL HEADER n
� / X 1 I 4. All worlk is to conform to the drawings and specifications of the architect and
- - - - engineer consultants.
J _ _ _ _ _ _ __ _ - - - - - - - - - - - - - --
- - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - ACW 644 APW5044 ACW 2644 I - 2X12 ACQ LEDGER BOLTED TO MASONRY W/ 3/8" EPDXY COATED I 5. The Contractor is to maintain a complete and up to date Set of plans on the
EXIST. WOOD FRAM D LINE OF EXIST. ROOF OVERHANG SCREWS W/ ANCHORS @ 12" OC MIN.
1 job site at all times
STOOP @ ENTRY NEW WALL TO ALIGN W/ EXIST. ROOF OVERHANG I FILL MASONRY BLOCK @ ANCHOR LOCATIONS ( 6. The drawings are not to be scaled under any circumstances.
U
NEW ENTRY DECK I ° 1 7. It shall be the Contractor's responsibility to ascertain all prevailing procedures
5/4 X 6 CEDAR DECKING O 2X12 ACQ DECK GIRDER ANCHORED TO 14" DIA. PIERS including storage and toilet facilities,protection of existing work to remain,acceSs to
EXIST. SLID. GL. DOOR 3'
@ Y TO MIN -0" BELOW GRADE I work area, hours of permitted work,availabilit of water and electric ower and all
EXIST. SLID. GL. DOOR I U y p
-R o - - - - - - - - - - - - I other conditions and restrictions for this particular location in order to execute the
work in a careful and orderly manner with the least possible disturbance to the public.
- - - - - - - - - - - - 8. The Contractor shall make the neccesary arrangements to utilities and services
LINE OF NEW ENTRY DECK
2 temporarily disconnected while performing the work as required.
1 _0 EQUAL EQUAL EQUAL 1 _0 9. The Contractor shall provide all dimensions and cut-outs for other trades.
2 10. The Contractor shall provide proper shoring and bracing for all remaining structure
W prior to removal of existing structure.
LU w 11. Plumbing, electrical, HVAC and similar work shall be performed by licensed
U11
Z EXIST. DECK persons who shall arrange for and obtain all required inspections.The General
EXIST. DECK LL
U
< Contractor shall be responsible for scheduling all other inspections as required.
EXISTING FIRST FLOOR PLAN a PROPOSED FLOOR PLAN PROPOSED FOUNDATION PLAN 12. The Contractor is solely responsible for construction safety and shall hold the
= 1'-0" 1 1.30.17 1/4" = 1'-0" 12.8.17 owner and architect harmless from litigation arising out of the Contractor's failure to
1/4"
X 1/4" = V-0" 1 2.8.17 REVISED 10.1 1.2 2 provide construction safety means and methods.
X REVISED 10.11.22
W
CONSTRUCTION NOTES
1. All footings shall rest on undisturbed soil at a minimum of 36" below fin. grade.
2. Poured concrete shall have a minimum psi of 3500 at 28 days unless noted.
3. Sill plates shall be preserved, treated wood and be installed above a 16 oz.
copper termite sheild.
4. Shingle siding shall conform to ASTM D 3679 and be installed in accordance
with the New York State Building Code and manufacturers specifications.
5. Pilings shall be installed by a licensed contractor to a depth and bearing agreed
upon by an engineer and certificates shall be issued stating same.
6. Unless otherwise noted all framing and structural wood components shall be
#2 or better Douglas Fir.
7. All framing techniques and methods shall be as prescriptive design based on
AF&P Wood Frame Construction Manual for One and two Family Dwellings (WFCM)
or as specified in R301.2.1.1
8. All building envelope components shall comply with Chapter 6 of the Energy
Conservation Code of the State of New or
9. Fireblocking shall be provided in all wood framed construction in accordance
_-._._ -.............___ _ with NYS Code R 602.8 to form an effective fire barrier between stories and
------- between the top story and roof space.
--.--..--- -- - - ---- - 10. Protective panels shall be provided for glazed openings in accordance with
NYS code R301.2.1.2 if they are required.
- --- ---- ---- 11. All portions of the new structure are designed to comply with local geographic
--
--- -
- EXIST. 2ND FL. ROOF - NO CHANGES- ----- ---- -----EXIST. 2ND FL. ROOF - NO CHANGES
and climatic criteria as stated In the following table.
GEOGRAPHIC & CLIMATE DESIGN CRITERIA
GROUND SNOW LOAD 45 ps1
WIND SPEED 130 MPH
- - - SEISMIC DESIGN CATATGORY B
WEATHERING SEVERE
-- ---' FROST LINE DEPTH 36"
- - - NEW FRAMED WALL UNDER EDGE OF ROOF OVERHANG TERMITE THREAT MODERATE TO HEAVY
DECAY SLIGHT T MODERATE
------------
------- -------- -_----- _---= EXIST 2ND FL FRAMING - N HA -
::...:..:....
----- WINTER DESIGN TEMPERATURE11
FLOOD HAZARD AS NOTED
- - -- - 1x6 CEDAR T&G SIDING TO MATCH EXIST.
-'
TYVEK HOUSE WRAP
EXIST. OVERHANG OF 2ND FL. ROOF
- --_- 3'-0"x6'- - 1/2' PLYWD SHEATHING
-- OPEN CARPORT - --.___- 2X8 @ 18" OC WALL FRAMING A- 101 PLANS, ELEVATIONS, SECTIONS, NOTES
R-30 BATT INSUL.
- /CW2644APW 5044 ACW 264 1/2" GYP. BD. @ INT.
EXIST. S . GL. DR. _- ADDITION @ EXIST. CARPORT A- 102 ELEVATIONS
EXIST. SLID GIL. DR. _-,_- _ EXIST. HALF WALL BEYOND STAIRS NO C ANGES
NO C A JGES
EXIST. ENTRY -
- - FOUNDATION PLAN
EXIST. HALF WALL @CELLAR STAIRS f
NEW FRAMED WALL 3/4" HARDWOOD FLOOR
FLOOR PLAN
-- 2X12 ACQ LEDGER BOLTED TO 1/2" PLYWD. SHEATHING
_ ELEVATION
_,. HOUSE vJ/ 3/8" EPDXY COATED 2X10 FL JOISTS @ 16" OC
DECKING R-38 BATT INSUL.
__... ......... ..... SCREWS @ 12" OC MIN. 5/4x6
. ..... 2X8 ACQ JOISTS @ 16" OC SECTIONS
EXIST. STOOP NEW DECK & STEPS - ANCHORED TO 2-2X12 ACQ 2X8@ 16"OC JOISTS
GIRDERS ANCHORED TO 14' 2X8 ACG SILL PL. ANCHORED TO
DIA CONC. PIERS TO MIN. 8" GONG. FOUNDATION WALL ON SCALE AS NOTED DECEMBER 10, 2017
3'-0" BELOW FIN. GRADE 16"x8" POURED CONC. FTG. MIN.
T-0" BELOW FINISHED GRADE
f I I I I
ELEVATION FRONT I I PROPOSED SOUTH ELEVATION (FRONT) I I 2" CONC. SLAB @MIN. MA ANCHORED 1 eSS
EXISTING SOUTH E > 1 _ A 10 1
3-2X12 ACQ GRADE BEAM ANCHORED
1/4" = 1'-0" 12.10. 17 1 I • "� TO 10" DIA. CONC. PIERS ON ,
1/4" = V-0" 12. 10. 172424"x12"J REVISED 10.1 1.2 2
I
I I L_ J 24"x24"x12" POUR. CONC. FTGS.
F I I SECTION # 1 ADDITION CARPORT permits draftingexpediting START 1 O F 2
f SECTION #2 NEW ENTRY DECK
1 f I
1/4" = V-0" 12.10.17 1/4" = 1'-0" 12. 10.17 POD BOX 49
_I EXIST.CELLAR STAIRS 1
- - - REVISED 10.1 1.22 JOAN CHAMBERS
- - - - - - - - - - - - SO1-294- NY 11971
631-294-4241
REVISED 10 . 1 1 .
ROOT RESIDENCE
6315 INDIAN NECK LANE
PECONIC N .Y.
EXISTING: SINGLE FAMILY RESIDENCE
SCTM# 1000-86-06-20
ZONE R-40 1 .79 ACRES
PROPOSED:
ENCLOSE EXISTING CARPORT (WITH EXIST. 2ND
FL. OVER ) TO CREATE NEW HOME OFFICE SPACE
...........
__EXIST. 2ND FL. ROOF NO CHANGES .......... ........... EXIST. 2ND FL. ROOF NO CHANGES ATTACHED TO EXIST. SINGLE FAMILY RESIDENCE.
EXTEND EXISTING ENTRY AND ADD NEW STOOP
.............
EXIST JG NO CHAN-. -S EXIST. EXIS7,G NO CHAW __S EXIST.
IL--------i I
EXIST. 2ND FLOOR & BALCONY NO CHANGES ...... EXIST. 2ND FLOOR & BALCONY NO CHANGES
NEW FRAMED WALL UNDER EDGE OF ROOF OVERHANG
V NEW W
EXIST. LIV. RM A; APW5050 AC 650 EXIST. LIV. RV
OPEN CARPORT WINDOW WINDOW
...............................
NO CHANGES NO CHANGE,'
....................... .................
...........I................ .. ..........
............ ......................................... NAILING/FASTENER SCHEDULE
......................
.. ...........................................
...................................................................
PROVIDE MSTA30 OR EQUAL
METAL STRAPS OVER RIDGE
EXIST. 112 WALL (FENCE) STAIRS .......................... REDUCED IN SIZE 1/2 WALL (FENCE) @ STAIRS TO ROOF RAFTERS @ 16" OC
TYP. NOT APPLICABLE IF
COLLAR TIES ARE PRESENT.
..........
......................... . .. .. ........................................... .. .................
8D COMMON @ 6" OC @ 4'-0- PERIMETER ZONE
8D COMMON @ 12' DO @ PANEL FIELD
8D COMMON @ GABLE ENDWALL RAKE
LREFER TO TABLE 3.8 WFCM- SBC
PROVIDE 8 - 10D COMMON NAI
EACH END OF COLLAR TIES
PROVIDE SIMPSON H2 / Flo OR 112" PLYWD. SHEATHING
EQUIVALENT HURRICANE TIES 6D COMMON @ 3" OC EDGE
TO SECURE ROOF RAFTER T=/ 5D COMMON @ 6- OC FIELD
PLATE AND WALL FRAME.
PROVIDE SIMPSON LPT4 OR
II
EQUIVALENT TO TIE RIM BOARD
EXIST.CELLAR STAIRS EXIST.CELLAR STAIRS TO DOUBLE PLATE TYP.
LI---- ------ - - - - -1 - - - - - - - - - - - I- = - - - - - - - - - -- -_ - - - -
PROVIDE SIMPSON H6 OR
EQUIVILANT TO TIE WALL STUDS
OF BOTH FLOORS TO PLATE &
BAND JOIST @ 16" OC T
PROVIDE SIMPSON H6 OR
EXISTING NORTH ELEVATION (REAR) PROPOSED NORTH ELEVATION (REAR) EQUIVALENT TO TIE WALL STUDS
TO PLATE &BAND JOIST @ 16"
1/4" l'-O" 12.10.17 1/4" = V-10" 12. 10. 17 CC TYP.
REVISED 10.11.22 PROVIDE SIMPSON LPT4 OR
EQUIVALENT TO TIE RIM BOARD,
TO SILL PLATE PLYWD. FLOOR SHEATHING
8D COMMON @ 6" OC EDGE
8D COMMON @ 12. OC FIELD
PROVIDE APPROPRIATE METAL
PLATE WASHER, NUT &ANCH R
BOLT TO TIE SILL PLATE TO
MASONRY FOUNDATION TYP
6'-0" OC FOR 1 STORY, T-0" FOR
2 STORIES. 12" FROM CORNERS &
OPENINGS AND BOLTS TO BE MIN.
12" DEEP.
ABBREVIATIONS
ADJ ADJACENT MIN. MINIMUM
.......... . ....................................... ...... ......... MOISTURE RESISTANT
. ......... ALUM. ALUMINIUM
APPD. APPROVED MW MILLWORK
BRD. BOARD NIC NOT IN CONTRACT
BIRK. BRICK OC ON CENTER
CIS OUT SWING
BOT. BOTTOM OPG. OPENING
CL CENTER LINE PL. PLATE
................................. CLG CEILING PLUMB. PLUMBING
COL. COLUMN PLYWD. PLYWOOD
................................ CONIC. CONCRETE
...........................................................-...................... CONT CONTINUOUS PT. PRESSURETREATED
EXIST. 2ND FL. ROOF NO CHANGES EXIST. 2ND FL. ROOF NO CHANGES- ...... ............................... ........... ...........- CT. CERAMIC TILE PNT. PAINTED
--------–---------
x PVC POLY VINYL CHLORIDE
......... DEMO. DEMOLISH RCP REFLECTED CEIL. PLAN
...... ....................................... DIA. DIAMETER
................ ..........I.......... .................... . .............. .............. DR. DOOR REQ. REQUIRED
.............. ............ DWG. DRAWING RM. ROOM
.......... R.O. ROUGH OPENING
.. ..... .......................... EA. EACH Sim. SIMILAR
............................ ........................I................................................................................................ ..................................I................................................................... ELEC. ELECTRICAL SPEC. SPECIFIED
. ............................. ................................ .. ........................ .. ..... ......................................................................................................................................-1................................... ............... ................................. - ELEV. ELEVATION
.I . .. � .......... ................................................ .................................................................................... I................... . .-__ . . .................................... EQ. EQUAL STL STEEL
..................... ****'" '**'**** '' *'''_..........................................I
' ''"" ** **-I .. ........... EXIST. EXISTING T & G TONGUE AND GROOVE
.......................................................................................................... ......I............................ ...... .. ............ ......... TEL. TELEPHONE
. .......... ........................................................................................... .......................... I 1_1 .. . .' ' '** EXT. EXTERIOR TBD TO BE DESIGNED
.. . . .......... ... ................................................................... ... ................... .................I................ F.P. FIREPLACE TO. TOP OF
. ................ LINE OF EXIST. 2ND FL. FRAMING NO CHANGES .............. ...... FIXED ................................................................................................................. .. ..................... ..........................I............................... FR. FRENCH
......... ..........................L ..... . ......... ........**'*'*...... .... .......... ........... L ....................................... GALV. GALVANIZED TYP. TYPICAL
. ... ............. ............................................................... .......... .............................. .........
.................. ........................ ........... TRIM BOARD GWB GYPSUM WALL BOARD UNO UNLESS NOTED OTHERWISE
.. . ................... HVAC HEATING, VENTING & VIF VERIFY IN FIELD
EXIST. OVERHANG OF 2ND FL. ROOF ............. .... .. ..........................................................................................................................................................................................................................................
..................... . ..................I............ ............................................................................ .................................................................................... .............................................................................................. AIR CONDITIONING W/ WITH
EXIST. LIV. RM I................................................................................................................... ............................ ....... ...........- ............. .... ............. EXIST. LIV. RM WD. WOOD
WINDOW ................ . ............. WINDOW INSUL. INSULATION WIP WATER PROOF
EXIST. ENTRY/MU[R I BEYOND
NEW FRAMED WALL TO ENCLOSE CARPORT .................... ...............- INT. INTERIOR
NOCHANGES ................................................... ............. ...................... .................... .... ................................. .................... ....................... NO CHANGES is IN SWING XPs EXTRUDED POLYSTYRENE
EXIST. PRIVACY FENCE J EXIST. PRIVACY FENCE ........................... .......................................................................................................... ............................. ...................................... . .............. ................ LBS POUNDS
NO CHANGES OPEN CARP RT NO CHANGES ........ ................ ..........
MAXIMUM
EXIST. STRIJCTURAL COILS & FTGS. MO. MASONRY OPENING
.................................
.............
..............
. .... ..... A- 101 PLANS, ELEVATIONS, SECTIONS, NOTES
... . .. ....
................... A- 102 ELEVATIONS
EXIST. ENTRY STOOP ......I......... ................ ...................................................- .............
NEW ENTRY DECK
NEW FOUNDATION
EXISTING EAST ELEVATION (SIDE) PROPOSED EAST ELEVATION (SID ) I L _ _ _ _1 ELEVATIONS
F-L 1/4" = V-0" 12.10.17 r--- — — — — — — — — T_-L— — — — — — — — — — — — — — — -r-L - -17
1/4" V-10" 12. 10.17 1- - - - - - -- - L—=- - - - - - - - - - - - - - --
. . . . . .. . LST. F�T .
—EXIST— —T REVISED 10. 11.22 — — — — — — — — — — — — — — — -- ExST- 1 -7- T"
CELLAR CELLAR
F_ STAIRS STAIRS -1
SCALE AS NOTED DECEMBER 10, 2017
I F oress
START ' A 102
PRO'
METAL
P
Typ
CC ,
1 permits I drafting I expeditinq , 2 OF 2
PO BOX 49
JOAN CHAMBERS SOUTHOLD NY 11971
631-294-4241
REVISED 10 . 1 1 . 2 2
ROOT RESIDENCE
6315 INDIAN NECK LANE
PECONIC N .Y.
EXISTING: SINGLE FAMILY RESIDENCE
SCTM# 1000-86-06- 20
EXISTING LIVING ROOM - NO CHANGES EXISTING LIVING ROOM - NO CHANGES
ZONE R-40 1 .79 ACRES
PROPOSED:
EXIST. 5"x5" STEEL COL. ON 16"x16' CONC. PIER W/ 4-#4 REBAR VERT. ENCLOSE EXISTING CARPORT (WITH EXIST. 2ND
24"x24"x10" CONC. FTG. W/ #5 REBAR @ 6"OC EXIST. 5"x5" STEEL COL. ON 16"x16' CONC. PIER W/ 4-#4 REBAR VERT.
24"x24"x10" CONC. FTG. W/ #5 REBAR @ 6"0C - NO CHANGES I FL. OVER ) TO CREATE NEW HOME OFFICE SPACE
EXIST. WOODEN HALF WALL LINE OF 2ND FL. BALCONY ABOVE - NO CHANGES I
L- - _- -EXIST. POUR GONG WALL & FTG. No CHANGES - _ ATTACHED TO EXIST. SINGLE FAMILY RESIDENCE.
EXIST. 3-1-3/4"x7-1/2" LVL UNDER BALCONY ABOVE - LOWER EXIST. FENCE TO 30" TALL - - L
- - --- --- - - - - - - - - - - - - -
Z j ADD PAVERS (p I - - - _ _ - _ I ���1� EXTEND EXISTING ENTRY AND ADD NEW STOOP
> CONC. SLAB T � - - - - - -rO
.- _ THIS AREA - REVELm I- EXI T. ELL R S AIR - I O HANGES W/ TOP OF STAIRI EXI T. ELL R S AIR - �HAN:;ETS ]
EX ST. ON S EPS TO CEL AR � I > DOWN FOUNDATION
co I I I Do
WN
x w I I Ir
Q I I I
I IUJ
DD AN[RAI - O C DE I L - - - - TABLE k30I.5 MINIMUM UNIFflRraLY DISTRIBUTED LIVE LOADS(in
occ - - - I - - - - - - - - m n (i pounds per square foot)
II i I I I W
41 I ....... . . � o ACW 36 11V E
EXIST. WOODEN HALF WALL Gd I 4 50 APW 5050 ACW 3650 I (� r- - - - - - - - - - - - - - - - ( v Q FJSE COAD"
2- 1-3/4"x11-1/2" LVL HEADER i
EXIST POUR. CONC. NALL & FTG. - NO CHANGES rx =
��- - - - - - - - - - - - - - � / I I I " Attics with limited storageg.h 20
EXIST. 3-1-3/4"x11-7/8" LVL UNDER WALL ABOVE w U I I NEW Y" MASONRY F UNDATION WALL ON 16"x8" I Oz
LL ° I I I Attics without stora b 10
W U w DUCTLESS MINI SPLIT ACOW/2HEA ERR w POUR D CONC. FTG. ge
z@ v I I v ( ( I I w 0 Deckse 40
Q O Q m w MODEL # O-ES-I2-HP-230E I I Q f� l a p
a EXIST. FL. JOISTS ABOVE _ Q I O Q a (D J s I I 1 U Exterior balconies 60
c 2-1-3/4"x9-1/2" LVL @ 16" OC m I m Q = EXISTING 2ND FL. FRAMING ABOVE IS I I I I ( p Fire escapes 40
LL = x LL U cn 2X10 @ 16" OC W/ R-30 INSULATION
LL m Oz CEILING/2ND FDARR MGNG TOREMAINI X I I ¢ - f i
EXIST. 1X6 I I I ( I I m Guardrails and handraiisa 200'
W I I o w / I I w I I ( I I Guardrails in fill components 50
N I _j NEW 2X8 FRAMED WALL W/ R-30 BATT INSUL. I I ( ( m Z it Passenger vehicle aro esa 50a
9 9 9
EXISTING COVERED CARPORT X I U I Rooms other than sleeping 40
p O LL SIDING TO MATCH AT EXT. I LL I ; ! I O U_
1/2" GYP. BD, @ INT. �f 1 m
3 1 1 � o I ( _- - -� w w z I I o LL rooms
- m LL O I I Sleeping rooms 3Q
I � U U �
LU I x o w I - 1 1 0 E � I : `. I o Stairs 40c
+6 I N ° I I x
\��. L : Q���' OPEN TO OFFICE (aj I -� °
wN %+'� @ 4M XR I WI I IwI N o X I i " x , GENERAL NOTES
PLATFORM z I Ip X � 'a
-I-� = I ml o x w N 1. All work shall conform to the requirements of the 2020 Residental Code of NY
I-�- I- i L U I IQ
EXIST. 3-1-3/4"x11-7/8" LVL UNDER WALL ABOVEI I
I
I I O I I ( N I Q State, County and Town Department Regulations, Utility Company requirements and
EXIST. �- - - - - - - - - - - - - - J J z I I �I best trade practises.
MUDRM. _LL 4-11 4 � 4JI 2. Before commencing work the Contractor shall file all documents required by the
c�
a LL I Q I , I Building Department, pay all fees required by local agencies and obtain all required
o I I LLI 2X10 FLOOR JOISTS @ 16" OC I ;. I permits.
w
o Q I Io1 3. The Contractor shall visit the site and verify all dimensions and the existing
ZI TIO I I conditions affecting the work prior to construction. Any discrepancies which would
o I o I I IJI 3 I I interfere with the satisfactory completetion of the work described herein shall be
o+ N o U I 8'-9 -94 I reported to the architect or property owner. Do not start work until such conditions
Fa s,
EXIST. DINING ROOM u-: , i EXIST. DINING ROOM g I I I NEW 8" MASO JRY FOUNDATION WALL ON 16"x8" I I have been examined and a Course of action mutually agreed upon. Failure to notify
POURED CONC FTG. - - - - - - - - the owner Or architect of unsatisfactory conditions will be construed as an acceptance
X LL +° CAE,NETS I a - - I I ry P
o I 2- 1-3/4"x11-v2" LVL HEADER I -- -- -- - - -- - - - - of the conditions to properly perform the required work.
X "< I 4. All work is to conform to the drawings and specifications of the architect and
J t.,. :; : �: .: .: .
- - - - - - - - - - - - - - - - - - - - - - - - - - engineer consultants.
EXIST. WOOD FRAM D
LINE OF EXIST. ROOF OVERHANG ACW 644 APW 5044 -A(5-W-2644 I F - 2X12 ACQ LEDGER BOLTED TO MASONRY W/ 3/8" EPDXY COATED I 5. The Contractor is to maintain a complete and up to date set of plans On the
STOOP @ ENTRY I SCREWS W/ ANCHORS @ 12" OC MIN. job site at all times
NEW WALL TO ALIGN W/ EXIST. ROOF OVERHANG FILL MASONRY BLOCK @ANCHOR LOCATIONS
I 6. The drawings are not to be scaled under any circumstances.
NEW ENTRY DECK I I Oc,co
J II 7. It shall be the Contractor's responsibility to ascertain all prevailing procedures
EXIST. SLID. GL. DOOR EXIST. SLID. GL. DOOR O 2X12 ACQ DECK GIRDER ANCHORED TO 14"
5/4 X 6 CEDAR DECKING DIA. PIERS I including storage and toilet facilities,protection of existing work to remain,access to
E _LJI
TO MIN T-0" BELOW GRADE
eo w
work area, hours of permitted work,availability of water and electric power and all
X - - - - - - - - - - - - other conditions and restrictions for this particular location in order to execute the
work in a careful and orderly manner with the least possible disturbance to the public.
LINE OF NEW ENTRY DECK - - 8. The Contractor shall make the neccesary arrangements to utilities and services
2 temporarily disconnected while performing the work as required.
EQUAL EQUAL EQUAL 1 _0 9. The Contractor shall provide all dimensions and cut-outs for other trades.
w 10. The Contractor shall provide proper shoring and bracing for all remaining structure
LL
W prior to removal of existing structure.
EXIST. DECK EXIST. DECK LL11. Plumbing, electrical, HVAC and similar work shall be performed by licensed
a persons who shall arrange for and obtain all required inspections.The General
> Contractor shall be responsible for scheduling all other inspections as required.
EXISTING FIRST FLOOR PLAN LL 12. The Contractor is sole) res y
1/4" = 1'-0" 1 1.30. 17 co owner
FLOOR PLAN PROPOSED FOUNDATION PLAN y responsible for construction safety and shall hold the
U) X 1/4" = V-0" 1 2.8.17 1/4" = V-0" 12.8. 17 owner and architect harmless from litigation arising out of the Contractor's failure to
UJ w REVISED 10.1 1.2 2 REVISED 10.1 1.2 2 provide construction safety means and methods.
CONSTRUCTION NOTES
1. All footings shall rest on undisturbed soil at a minimum of 36" below fin. grade.
2. Poured concrete shall have a minimum psi of 3500 at 28 days unless noted.
3. Sill plates shall be preserved, treated wood and be installed above a 16 oz.
copper termite sheild.
4. Shingle siding shall conform to ASTM D 3679 and be installed in accordance
with the New York State Building Code and manufacturers specifications.
5. Pilings shall be installed by a licensed contractor to a depth and bearing agreed
upon by an engineer and certificates shall be issued stating same.
6. Unless otherwise noted all framing and structural wood components shall be
#2 or better Douglas Fir.
7. All framing techniques and methods shall be as prescriptive design based on
AF&P Wood Frame Construction Manual for One and two Family Dwellings (WFCM)
or as specified in R301.2.1.1
8. All building envelope components shall comply with Chapter 6 of the Energy
Conservation Code of the State of New York.
9. Fireblockling shall be provided in all wood framed construction in accordance
with NYS Code R 602.8 to form an effective fire barrier between stories and
between the top story and roof space.
10. Protective panels shall be provided for glazed openings in accordance with
-- -- - ._...--------- ---...--- -- ----- --..........----................................... - --.......- -------
NYS code R301.2.1.2 if they are required.
--- -- ------EXIST. 2ND FL. ROOF - NO CHANGES- `--- ---- -- " -._._.._--"- --- -- - '--EXIST. 2ND FL. ROOF - NO CHANGES----------- 11. All portions of the new structure are designed to comply with local geographic
and climatic criteria as stated in the following table.
GEOGRAPHIC & CLIMATE DESIGN CRITERIA
GROUND SNOW LOAD 45 ps 1
WIND SPEED 130 MPH
SEISMIC DESIGN CATATGORY B
----- - - --......_.................. ._....
WEATHERING SEVERE
_.._.....__.....---...._...-_._._..._........._.........._-- _-- FROST LINE DEPTH 36"
_..-- -- ---N E W
_._....._
-- FROST__.....____._.-___.._............__-- ______ - FRAMED WALL UNDER EDGE OF ROOF OVERHANG-
TERMITE THREAT MODERATE TO HEAVY
EXIST. 2ND FL. FRAMING - NO CHANGES
_ DECAY SLIGHT TO MODERATE
WINTER DESIGN TEMPERATURE 11
FLOOD HAZARD
EXIST. OVERHANG OF 2ND FL. ROOF ___ 1x6 CEDAR T&G SIDING TO MATCH EXIST. AS NOTED
TYVEK HOUSE WRAP
3'-0"x6'- 1/2" PLYWD SHEATHING
OPEN CARPORT"- R-30 BATT INSUL. A- 101 PLANS, ELEVATIONS, SECTIONS, NOTES
2X8 @ 18" OC WALL FRAMING
_
/CW2644 APW 5044 �264
EXIST. SLID uL. DR. _ EXIST. HALF WALL BEYOND STAIRS EXIST. SIA). GL. DR. - 1/2" GYP. BD. @ INT. A- 102 ELEVATIONS
NO C A GES - NO C ANGES ADDITION @ EXIST. CARPORT
EXIST. ENTRY --------- -
EXIST. HALF WALL @ CELLAR STAIRS
........................................ .
NEW FRAMED WALL 3/4" HARDWOOD FLOOR FLOOR PLAN, FOUNDATION PLAN
_.. -..
2X12 ACQ LEDGER BOLTED TO 1/2" PLYWD. SHEATHING ELEVATION
HOUSE W/ 3/8" EPDXY COATED
2X10 FL. JOISTS @ 16" OC
SCREWS @ 12" OC MIN. 5/4x6 DECKING R-38 BATT INSUL.
. ...,.... . .. ........ 2X8 ACQ JOISTS @ 16" OC
EXIST. STOOP NEW DECK & STEPS ANCHORED C 2-2X12 ACQHORED TO 14"
GIRDERS ANC2X8@ 16"OC JOISTS
2X8 ACG SILL PL. ANCHORED TO SECTIONS
DIA CONC. PIERS TO 0" BELOW FIN. GRADEN. 816"x8" POURED CONOC. WALL. MN. SCALE AS NOTED DECEMBER 10, 2017
T-0" BELOW FINISHED GRADE
EXISTING SOUTH ELEVATION (FRONT) I f J I I PROPOSED SOUTH ELEVATION (FRONT) ( r ''
1/4" = 1'-0" 12. 10. 17 f rJ - I-� 1/4" = 1'-0" 1 2.1 0.17 I I 2" CONC. SLAB @MIN. MA ANCHORED
1 ess
3-2X12 ACQ GRADE BEAM ANCHORED s!STARTn O
I I L_ - J REVISED 10. 1 1.22 ( I TO 10" DIA. POUR. PIERS ON
J- -T I I ,. ..
24"x24"x12" POUR. CONC. FTGS.
I f I I ermits draftin expediting � O F 2
f 1 SECTION #2 NEW ENTRY DECK SECTION # 1SECTION # 1 ADDITION CARPORT
EXIST.CELLAR STAIRS I 1/4" = V-0" 1 2. 10.17 1/4" = 1 -0 12.10.17
PO BOX 49
- - - - - - - - - - REVISED 10. 1 1.22 JOAN CHAMBERS
I- - - - - �- � � SOUTHOLD NY 11971
631-294-4241
REVISED 10 . 1 1 . 22
ROOT RESIDENCE
6315 INDIAN NECK LANE
PECONIC N .Y.
EXISTING: SINGLE FAMILY RESIDENCE
SCTM# 1000-86-06-20
ZONE R-40 1 .79 ACRES
PROPOSED:
ENCLOSE EXISTING CARPORT (WITH EXIST. 2ND
FL. OVER ) TO CREATE NEW HOME OFFICE SPACE
- ----"- —
EXIST. 2ND FL. ROOF - NO CHANGES __.__.—__ _—.__ _EXIST. 2ND FL. ROOF - NO CHANGES —_ _ ATTACHED TO EXIST. SINGLE FAMILY RESIDENCE.
- "--- - -.
EXTEND EXISTING ENTRY AND ADD NEW STOOP
........................ _ ... . . . ............................ .............................
EXIST IEG - NO CHAN S EXIST. EXIS I G - NO CHAW ES EXIST.
EXIST. 2ND FLOOR & BALCONY - NO CHANGES EXIST. 2ND FLOOR & BALCONY - NO CHANGES"
NEW FRAMED WALL UNDER EDGE OF ROOF OVERHANG
NE / NEW \ EW
EXIST. LIV. RM
---------- AC�1 3650 APW 5050 ACT 3650 EXIST. LIV. RM
WINDOW WINDOW
OPEN CARPORT / \
NO CHANGES NO CHANGES
...................................
................................ \ /
...................._
NAILING/FASTENER SCHEDULE
. ................ . ........
. ........... .
......,_.... ......._......... ... ................................ PROVIDE MSTA30 OR EQUAL
METAL STRAPS OVER RIDGE
EXIST. 1/2 WALL (FENCE) @ STAIRS """'"""""'""""' . """' c REDUCED IN SIZE - 1/2 WALL (FENCE) @ STAIRS """"......""" TO ROOF RAFTERS @ 16" OC
.. .. .................... N .._. ......,.................... TVP. NOT APPLICABLE IF
I COLLAR TIES ARE PRESENT.
...................................... ....... ..._. .._.. .. .-..... ... .............
co
8D COMMON @ 6" OC @ 4'-0" PERIMETER ZONE
8D COMMON @ 12" OC @ PANEL FIELD
8D COMMON @ GABLE ENDWALL RAKE
REFER TO TABLE 3.8 WFCM- SBC
r1 — I PROVIDE 8 - 10D COMMON NAI
LI EACH END OF COLLAR TIES
PROVIDE SIMPSON H2 /H10 OR 1/ COMMON @ 3" HI EDGE
II
PLYWD.
EQUIVALENT HURRICANE TIES 6D COMMON @ 6"OC FIELD
TO SECURE ROOF RAFTER 6D OMMON SHEATHING
PLATE AND WALL FRAME.
I I I PROVIDE SIMPSON LPT4 OR
EQUIVALENT TO TIE RIM BOARD
I I EXIST.CELLAR STAIRS � I I I EXIST.CELLAR STAIRS � I
TO DOUBLE PLATE TYP.
L. 1.- - - - -- - - - -- - - _Z - - - - -1 - - - - - - - - - - L1- - - - - - -- -- -- - -- - - - - - - -1 - -- -- - - -- .... -- -- —
PROVIDE SIMPSON H6 OR
EQUIVILANT TO TIE WALL STUDS
OF BOTH FLOORS TO PLATE &
BAND JOIST @ 16" OC T
EXISTING NORTH ELEVATION (REAR) PROPOSED NORTH ELEVATION (REAR) PROVIDE NT TO TI Hs OR
LL
EQUIVALENT TO TIE WALL STUDS
TO 1/4" = 1'-0" 12. 10.17 1/4" = V-0" 12. 10. 17 OC TYp PLATE & BAND JOIST @
REVISED 10.1 1.2 2 PROVIDE SIMPSON LPT4 OR
EQUIVALENT TO TIE RIM BOA
TO SILL PLATE PLYWD. FLOOR SHEATHING
8D COMMON @ 6" OC EDGE
8D COMMON @ 12" OC FIELD
PROVIDE APPROPRIATE METAL
PLATE WASHER, NUT &ANCH
BOLT TO TIE SILL PLATE TO
MASONRY FOUNDATION TYP
6'-O" OC FOR 1 STORY, T-0" FOR
2 STORIES. 12" FROM CORNERS &
OPENINGS AND BOLTS TO BE MIN.
12" DEEP.
ABBREVIATIONS
ADJ ADJACENT MIN. MINIMUM
-- ..... -... - --
-""""""" ALUM. ALUMINIUM MR MOISTURE RESISTANT
APPD. APPROVED MW MILLWORK
NIC NOT IN CONTRACT
BBD. BOARD OC ON CENTER
BRK. BRICK OS OUT SWING
- BOT. BOTTOM OPG. OPENING
CL CENTER LINE PL. PLATE
CLG CEILING PLUMB. PLUMBING
COL. COLUMN PLYWD. PLYWOOD
......... CONC. CONCRETE
PT PRESSOR TREATED
............. ..... .. . . . .. _ TILE PNT. PAINTED
CONT CONTINUOUS
EXIST. 2ND FL. ROOF - NO CHANGES.._ I _ _ _______— EXIST, 2ND Fl. ROOF - NO CHANGES CT. CERAMIC T
DEMO. DEMOLISH
PVC POLY VINYL CHLORIDE
I .................. .................................... .... ...... ._.................... .... DIAMETER RCP REFLECTED CEIL. PLAN
f..._. DIA. DI REQ. REQUIRED
DR. DOOR
-- I DWG. DRAWING
I. ................_..........._.._)....)........._...._."................................................... OPENING
M
_ ROUGH
I. ................. .. ......................................................j .I ..... ..... .... ... ......... .. SIM. SIMILAR
_.^
EACH
ELEC
ELECTRICAL
--------- - .......-I....L.. -._.._....--------------- --- __ - I.._�....................... ..... ----- - SPEC. SPECIFIED
. ................ ..._........................................................................................ .. .. ... .........................
--- ..................... __..._.._..__....__._ _ - �- - ._..
ELEVATIONSTL STEEL
I I I ......................................_........_..._._. .. . ......................................_L.....�.._......................................................................_.................. EO. EQUAL
I... . . f . _ I .............................................................. ... -....... ........................_.........................................................................................I_..........................-.--._.................._._........................_.._.............. EXIST. EXISTING T & G TONGUE AND GROOVE
.................... . .. .. .................... . . .........................I ............_.._.................... _ ............................................................................................. ... G
_........................................................................................._.I............................................................................................................ TEL. TELEPHONE
I...................................................................................................................................................................._............_................................I..........._.................... ........... .......................................... EXT. EXTERIOR
_........ ... _. .... { . E DESIGNED
F.P. FIREPLACE
C
TBD TO BE
D
I
I
1'
I FL. FRAMING - NO CHANGES.., .... ..... ........................... ........ . ................................. ... . .. ...._........ ..._........... .. _................................................................................... TO.
LINE OF EXIST. 2ND
FR. F
TOP OF
FIXED
BENCH
(- - -... ....- -'- _:.._:.: :' -- - - - -- - - I- - - - - - - - L .._ - ... ........_..................................................._.. ..._......................................................._....... ... ........................................................................................................ TYP. TYPICAL
- - - - -- - - - - - - - J - - - - - - - A CAL
G LV. GALVANIZED
........_................................................................................................................................................. LINO UNLESS NOTED OTHERWISE
TRIM BOARD GWB GYPSUM WALL BOARD LIN VERIFY O FIELD
. ............... .................................................... . .....................................................
EXIST. OVERHANG OF 2ND FL. ROOF _.... .......... _._.. ........- HEATING, VENTING & VIF
..................... ....................................... ... ... ....................................................._.._......................
AIR CONDITIONINGW/ WITH
EXIST. LIV. RM E M L
........................................................... EXIST. LIV R WD
WINDOW _............................................................ _..................
INSU . INSULATION WOOD
---- - - -- - -- WINDOW WP WATER PROOF
EXIST. ENTRY/MU R BEYOND ................................ ..NEW FRAMED WALL TO ENCLOSE CARPORT ................._.....................-.................................................._........................................... INT. INTERIOR
NOCHANGES ............................................................. .......................................................................................................... .. ... . ..... ........................ ...,............................ ........... NO CHANGES IS IN SWING XPS EXTRUDED POLYSTYRENE
EXIST. PRIVACY FENCE EXIST. PRIVACY FENCE
...........
.................................................... ........... ................................................................................................................................................... LBS POUNDS
MAX. MAXIMUM
NO CHANGES p NO CHANGES
I OPEN CARP RT
................................................... ................................ .. ..................................................
EXIST. STR CTURAL COLS & FTGS. ................................... . ..... ._...._._._............ ....... . . ... ........ MO. MASONRY OPENING
_.................
.............................. ............................ .. .. ATIO SECTIONS,- 101 PLANS, ELEVATIONS, SE NS, NOTES
.. .............. ............................................ ................................................. .......,...... ................... ... N
- ......... . ................................... ......... ........................ .... ..... ... ........ ....... .. .... M A- 102 ELEVATIONS
EXIST. EVTRY STOOP
NEW ENTRY DECK
E-1 71
I I I NEW FOUNDATION
I- -- - -- I �- - - -
EXISTING EAST ELEVATION (SIDE) ( - - - I PROPOSED EAST ELEVATION (SIDE) I I I L _ _ _ _ I ELEVATIONS
1/4" = V-0" 12. 10.17 -- I - � 1/4" = 1'-0" 12. 10. 17 r- - - - - - - - 4 T. FT . �
EXIST. FT
L_ - J I_ I- - - - - - - - - �-- - - - - - - -- - - -EXIST-- __ T REVISED 10. 1 1.2 2 - - - -
_ _ _ L _ CELLAR_
CELLAR I I STAIRS
I � STAIRS � I
i- — — — — - I SCALE AS NOTED
I DECEMBER 10, 2017
- - � I ress �,:,�.�..
I i � I �'1e.M
Li LL - - _ _ � � A 102
, permitsSTART draftingex editin 2 O F 2
PO BOX 49
JOAN CHAMBERS SOUTHOLD NY 11971
631-294-4241