Loading...
HomeMy WebLinkAbout45184-Z SSU&LSC Town of Southold o� o� 12/21/2020 y P.O.Box 1179 a • 53095 Main Rd y �ao�¢ Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41710 Date: 12/21/2020 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 350 Macdonalds Rd., Laurel SCTM#: 473889 Sec/Block/Lot: 145.4-14.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/26/2020 pursuant to which Building Permit No. 45184 dated 9/9/2020 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as applied for. The certificate is issued to Friedman,Alex&Tennenbaum,Erica of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45184 11/23/2020 PLUMBERS CERTIFICATION DATED i 1 Authorize Signature FFol,r TOWN OF SOUTHOLD BUILDING DEPARTMENT y 2 TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45184 Date: 9/9/2020 Permission is hereby granted to: Friedman, Alex 9 Prospect Park W Apt 11 C Brooklyn, NY 11215 To: install roof-mounted solar panels on existing single-family dwelling as applied for with flood permit. At premises located at: 350 Macdonalds Rd., Laurel SCTM #473889 Sec/Block/Lot# 145.4-14.1 Pursuant to application dated 8/26/2020 and approved by the Building Inspector. To expire on 3/11/2022. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Flood Pern7it $100.00 Total: $300.00 t g Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. August 20, 2020 New Construction: Old or Pre-existing Building: x (check one) Location of Property: 350 Macdonald Road Laurel House No. Street Hamlet Owner or Owners of Property: Alex Friedman Et Erica Tennebaum Suffolk County Tax Map No 1000, Section 145 Block 4 Lot 14.1 Subdivision 1 Q Filed Map. Lot: Permit No. -q'f ` U Date of Permit. Applicant: GreenLogic LLC Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: x (check one) Fee Submitted: $ 50 A icant Signature Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) 1, �- f'i ct residing at�3 5D HA&,D#Ja tt (Print property owner's name) I (Mailing Address) Lo—tAPFL-f I Lq Lf 0 do hereby authorize GreenLogic LLC (Agent) to apply on my behalf to the Southold Building Department. (Owner's Signature) (Nate) V 1j;L L 14 (Print Owner's Name) z�r• "�;y ., , ;<c . ., ,� �'�'.,.�, .�e `ry'"",,:»'�,ro-e.-�„w`�: ,-3,- vy-rx. `ca nx�. �i,�,zrc.�,- � � . �,eT s � � i;fiq'�` T � �:^c`�`r:�' ;z.r `• :�,°vk xuy�,;,« ���, ��.�� � , .F:al�'�Fa<.r�� v . ''" �:a�,` a��"����>�T,-;; � r,�.= ,�::-,'E>a.��,� ,s��e`.�s_�a '-a. ��r:R a4,_..,r,.6;a� `.. �,� � ...�•�;,°,F� ,, �.:^ ., �r✓ �y ==+-,.a,`� ;��aa�',� ,'.xt�:� - �,F„u,,'F.Y�Vii,. "' aM�,�a...,���, _ „. . ,,,,,,, ,.�a�l" :r. ;.`Yr.. %�i���,`;�, � '�`oa�a -< �:L"f`,� a�;�.�..�•��a,�rr.;, wa+�,z:�i'�'�y,">&�y"^��� .�rt �n.:<�z;�t€�'^3�`�'��`e--� , ��e �'-max ,,, w-;. ..�' �x. � ��<.���:,.�a�� .�� .:...; �" �j�;,>�;<�.� �� �� ��"3°• �:�,�y i,` �. � a,�;,x,,,, ��'�..._.. 'z°° �v �, ., _ �a t�`°�.a`,�,.`.._ ��svZ..a..�r.�.:..��•.. °�. ,�,�,.�..._.��`� .,,.�' ',,:,.�... Y�&�s�a�akA�..�. fi�..�. , S CONSENT TO INSPECTION Alexander Friedman , the undersigned, do(es)hereby state: Owner(s)Name(s) That the undersigned(is) (are)the owner(s) of the premises in the Town of Southold, located at 350 Macdonald Road, Laurel, NY 11948 , which is shown and designated on the Suffolk County Tax Map as District 1000, Section , Block ,Lot That the undersigned(has) (have)filed, or cause to be filed, an application in the Southold Town Building Inspector's Office for the following: solar panels That the undersigned do(es)hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon,to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws, ordinances,rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections, do(es) so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances,rules or regulations of the Town of Southold. Dated: (Si ature) Q3 K0, 5 _ Name) (Signature) FVC ca- al ��„LM (Print Name) soUl�®� Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 c sean.deviin(a)-town.southold.nv.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Alex Friedman Address: 350 Macdonalds Rd city Laurel st: NY zip: 11948 Building Permit#: 45184 Section: 145 Block. 4 Lot 14.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA- GreenLogic LLC License No: 43858ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Surrey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment. 11.445kW Roof Mounted PV Solar Electric System w/ (35) SunPower SPR-320-327- E-AC Modules and (35) SunPower SPR-320-327-E-AC Inverters and (1) SunPower Monitor Notes Solar Inspector Signature: Date: November 23, 2020 S Devlin-Cert Electrical Compliance Form.xls ho�aoe souryo{o � *36-0 m� I!'� # # TOWN OF SOUTHOLD BUILDING DEP . courm,N�'' 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] "ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ( ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: Ney Aec,ic DATE `. INSPECTOR pF SO/¢yolo � ��� -3 � �p * TOWN OF SOUTHOLD BUILDING DEPT. `yCourm,��' 765-1802 INSPECTION , , [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] -FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) NX& ELECTRICAL (FINAL) - [ ] CODE VIOLATION [ ] PRE C/O F- REMARKS: ,t L DATE �� INSPECTOR ��` Pacifico Engineering PC _ _ Engineering Consulting 700 Lakeland Ave, Suite 2B P C Ph.631-988-0000 Bohemia, NY 11716 IN G c solar@pacificoenglneering.com - - December 1,2020 r Town of Southold Building Department CG L 54375 Route 25, P.O. Box 1179 2 — L5 Southold, NY 11971 DEC _ 7 2020 Subject: Solar Energy Installation for Alex Friedman 350 Macdonald Roads Laurel, NY 11948 I have reviewed the solar energy system installation at the subject address on December 1,2020.The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2020 Residential Code of New York State and ASCE7-16. To my best belief and knowledge,the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice,with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer n �M Ralph Pacifico,Professional Engineer NY 066182/NJ 24GE04744306/FL 87297 FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(IST) FOUNDATION(2ND) ROUGH FRAMING& PLUMBING INSULATION PER N.Y. y STATE ENERGY CODE i FINAL 6A No 12 cmi 3? o • m X 310 . d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802Planning Board approval FAX: (631) 765-9502 Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined ,20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: ' Approved '20 Mail to. GreenLogic LLC Disapproved a/c 97 North Sea Road, Southampton, NY 11968 41 Phone: 631-771-5152 Expiration ,20 _0�2/_ & ® ALO ,g D Building Inspector AUG 2 6 2020 APPLICATION FOR BUILDING PERMIT Date August 20 20 20 BU"MDINO DEPT, INSTRUCTIONS a. This appfication MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4' sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. GreenLogic LLC l (Signature of applic4A or name,if a corporate n) 97 North Sea Road, Southampton, NY 11968 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Contractor Name of owner of premises Alex Friedman Et erica Tennebaum (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer Nesim Albukrek, President (Name and title of corporate officer) Builders License No. 40227-H Plumbers License No. N/A Electricians License No. 43858-M E Other Trade's License No. N/A 1. Location of land on which proposed work will be done: 350 - Macdonald Road Laurel House Number Street Hamlet County Tax Map No. 1000 Section 145 Block 4 —Lot 14.1 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single family dwelling b. Intended use and occupancy Single family dwelling 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work Roof mounted solar electric system 4. Estimated Cost $39,600Fee $200 (Description) (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase 2/2018 Name of Former Owner George Hochbrunner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO X 13. Will lot be re-graded? YES NO X Will excess fill be removed from premises?YES NO X Alex Friedman 350 Macdonald Rd 14.Names of Owner of premises Erica Friedman Address Laurel, NY 11948 Phone No. 716-572-4741 Name of Architect James J. Stout Address 2 Greg Ln, E. Northport Phone No 631-858-9388 Name of Contractor GreenLogic LLC Address97 North Sea Road Phone No. 631-771-5152 _ Southampton, NY 11968 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES X NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES X NO * IF YES,D.E.C.PERMITS,MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO X * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk Nesim Albukrek being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent, Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the,application filed therewith. Sworn to before me this/ d day of Notary Public BARBARA A CASCIOTTA Signature of Applican Notary Public-State of New York No.01-CA4894969 Qualified In Suffolk County Commission Expires May 11.2023 r , a ,R APPLICATION PAGE 1 of 4 TOWN OF SOUTHOLD I1LOODPLAIN DEVE, LOPMENT PERMIT APPLICATION This form is to be filled out in duplicate. SECTION 1• GENERAL PROVISIONS (APPLICANT to read and sien)- 1. No work may start until a permit is issued. 2 The permit may be revoked if any false statements are made berein. 3. If revoked, all work must cease until permit is rc-issued. 4. Development shall not be used or occupied until a Certificate o(Compliance is issued. 5. The permit will expire if no work is commenced within six months of issuance. 6. Applicant is hereby informed that other permits may be required to fulfill local,state and federal regulatory requirements. 7. Applicant hereby gives consent to the Local Administrator or his/her representative to make reasonable inspections required to verify compliance. 8_ I,THE APPLICANT,CERTIFY THAT ALL STATEMENTS HEREIN AND IN ATTACHMENTS TO THIS APPLICATION ARE,TO THE BEST OF MY KNONVLEDGE,TRUE AND ACCURATE. (APPLICANTS S2*ATURE) �AZ DATE 8/20/20 SECTION 2• PROPOSED D LOPMENT(Tb be completed by APPLICA—M AME ADDRESS TELEPH NE APPLICANT GreenLogic LLC 97 North Sea Road, Southampton, NY 11968 631-771- 152 BUILDER GreenLogic LLC 97 North Sea Road, Southampton, NY 11968 631-771-5152 ENGINEERJames J. Stout Architect &Assoc. 2 Greg Lane, East Northport, NY 11731 631-858-9388 PROJECT LOCATION: To amid delay in processing the application. please provide enough information to easily identify the project location. Provide the street address, lot number or legal description (attach) and, outside urban areas. the distance to the nearest intersecting road or well-known landmark A sketch attached to this application showing the project location would be helpful. Roof mounted solar electric system FDP(93) APPLICATION PAGE 2 Of: d ---- DESCRIPTION OF WORK (Check all applicable boxes) A. STRUCTURAL DEVELOPMENT ACI'IV17Y STRUCTURE_ TYPE ❑ New Structure W Residential (1-4 Family) ❑ Addition ❑ Residential (More than 4 Family) ® Alteration O Non-residenual (Floodproofitng? ❑ yes) ❑ Relocation ❑ Combined Use (Residential & Commercial) ❑ Demolition ❑ Manufactured (Mobile) Home (In Manu- 0 Replacement factured Home Park? ❑ Yes) ESTIMATED COST OF PROJECTS 39,600 B. OTHER DEVELOPMENT ACTIVITIES: ❑ Fill ❑ Mining ❑ Drilling ❑ Grading ❑ Excavation (Except for Structural Development Checked Above) ❑ Watercourse Alteration (Including Dredging and Channel Modifications) ❑ Drainage Improvements (Including Culvert Work) • Road, Street or BrUge Construction ❑ Subdivision (New or Expansion) ❑ Individual Witer or Ser System b ® Other (Please Specffy) 'Roof mounted sol After completing SECTION 2, APPLICANX should submit form to Local Administrator for review. ECTION 3: DPL.AIN DETERMINATION o be coin leted by LOCAL ADMINISTRATORRI The proposed development is located on FIRM Panel No. Dated The Proposed Development: ❑Is hIQ'1r located in a Special Flood Hazard Area (Notify the applicant that the application review is complete and NO FLOODPLAIN DEVELOPMENT PERM T IS REQUIRED). ❑ Is located is a Special Flood Hazard Arca. FIRM zone designation is 1170-Year flood elevation at the site is: Ft. NGVD (MSL) ❑ Unavailable Cl The proposed development is located in a floodway FBFM Panel No. Dated ❑ See Section 4 for additional instructions SIGNED DATE APPLICATION PAGE 3 OF 4 SECTION 4• ADDITIONAL INFORMATION REQUIRED (To be completed by LOCAL ADMINISTRATOR) The applicant must submit the documents checked below before the application can be processed- 0 A site plan showing the location of all cnsung structures, water bodies, adjacent roads, lot dimensions and proposed development. O Development plans, drawn to scale, and specifications,including where applicable:details for anchoring structures,proposed elevation of lowest floor(including basement), types of water resistant materials used below the First floor,details of floodproofing of utilities located below the fust floor and details of endostucs below the first floor. Also ❑Subdivision or other development plans (If the subdivision or other development exceeds 50 lots or 5 acres, whichever is the lesser, the applicant trust provide 100-year flood elevations if they arc not otherwise, available). ❑ Plans showing the extent of watercourse relocation and/or landform alterations. O Top of new fell elevation Ft. NGVD (MSL). ❑ Floodproofing protection level (non-residential only) Ft.'NGVD (MSL). For f[oodl5rW= p. oofed structures, applicant must attach certification from registered engineer or architect. ❑ Certification n from a registered engineer that the proposed activity in a regulatory floodway will not result in any increase in the height of the 100-year flood. A copy of all data and calculations supporting£.his Finding must also be submitted. ❑ Other: SECTION 5 PERMIT DETERMINATION (To be completed b LOCAL ADMINISTRATORI I have determined that the proposed activity. A.❑ Is B.t3 Is not . in conformance with provisions of Local Law # . 19 The permit is issued subject to the conditions attached to and made part of this permit. SIGNED , DATE If BOX A is checked, the Local Administrator may issue a Development Permit upon payment of designated fee. If BOX B is checked, the Local Administrator will provide a written summary of deficiencies. Applicant may revise and resubmit an application to the Local Administrator or may request a bearing from the Board of Appeals APPLICATION a _ PAGE4OF4 APPEALS Appealed to Board of Appeals? ❑ Yes ❑ No Hearmg date: Appeals Board Decision --- Approvcdl ❑ Yes ❑ No Conditions SECTION G• AS-BUILT ELEVATIONS (To be subrnmed by APPLICANT' before Certificate of Comphancc is issued The following information must be provided for project structures_ This section must be completed by a registered professional engineer or a licensed land surveyor (or attach a certification to this application). Complete 1 or 2 below, I. Actual (As-Built) Elevation of the top of the lowest floor, including basement(in Coastal High Hazard Areas, bottom of lowest structural member of the lowest floor, excluding piling and columns) is: FT. NGVD (MSL). 2. Actual (As-Built) Elevation of floodproofmg protection is FT. NGVD (MSL). NOTE: Any work performed prior to submittal of the above information is at the risk of the Applicant. SECTION 7 COMPLIANCE ACTION (To be completed by LOCAL ADMINISTRATOR) The LOCAL ADMINISTRATOR will complete this section as applicable based on inspection of the project to ensure compliance with the community's local law for flood damage prevention. INSPECTIONS: DATE BY DEFICIENCIES? ❑ YES ❑ NO DATE BY DEFICIENCIES? ❑ YES ❑ NO DATE BY DEFICIENCIES? ❑ YES ❑ NO SECTION 8• CERTIFICATE OF COMPLIA.NCE(To be completed by LO AL ADMINISTRATOR) Ceriificam of Compliance issued: DATE: BY: Attachment B SAMPLE CERTIFICATE OF COMPLIANCE for Development in a Special Flood Hazard Area TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE FOR DEVELOPMENT INA SPECIAL FLOOD HAZARD AREA (OV4'NER MUST RETAIN THIS CERTIFICATE) PREMISES LOCATED AT: PERMIT NO. PERMIT DATE OWNERS NAME AND ADDRESS: CHECK ONE: 0 NEW BUILDING ❑ EXISTING BUILDING O VACANT LAND THE LOCAL ADMINISTRATOR IS TO COMPLETE A. OR B. BELOW: A. COMPLIANCE IS HE, CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # , 19 SIGNED: DATED: B. COMPLIANCE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # , 19-, AS MODIFIED BY VARIANCE # , DATED SIGNED: DATED: C/C(93) Scott A. Russell It STORM WA' IER SUPERVISOR tfi I��1[Ah A\Gr1Ehy[]E .'7C' -SOUTHOLD TOWN HALL-P.O.Box 1179 a 53095MainR6ad-SOUTHOLD,NEWYORK 11971 Town of Southold CRAFTER 236 - STORMWATER MANAGEMENT WORK SHEET (TO BE COMPLETED BY THE APPLICANT ) DOES 'I'I-IIS 'PROJECT IINVOLVE ANY OF THE FOI..I.(.WIN&. (CHECK ALL "THAT APPLY) i Yes No ❑Q A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑0 B. Excavation or f illing involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑❑ -C. Site preparation,on slopes which exceed t0 feet vertical rise to - I 100,feet of horizontal distance. 00 Di 'Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑0 E. Site preparation within the one-hundred-year floodplain as depicted ? on FIRM Map of any watercourse. it ❑0 F. Installation of new oi• resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management l Control Plant was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered`YES to one-or more of the above,please submit Two copies of a Stormwater Management Control Plan and a completed Check ListTorm to the Building Department with your Building Permit Application. 1 , APPLICANIT sPrca its p:ner.Dern Protea tonal,A�nanl,fontractor,t7iher} S•C•T.M. 1000 Rate: District NAxLiE: LC (Nesim Albukrekl GreenLoaic L 145 4 14.1 8/20/20 Section Block Lot 3 ! s 3 OR BUILDING DCPARTAN—J USE ONLY Contac(Inforttlattam 631-771-5152 i i 3 €Fekpdar riumrir i Reviewed By: 9 - - ' Date- 3 i Property Address/Location.of Construction Work- — .— ._._— — — — — — — — — ! I, Approved for processing Building Permit. , 350 Macdonald Road ❑ Stormwater Management Control Plan Not Required i Laurel NY 11948 . ' ; ; — — — — — — —' — — — — — — — — — — ;( Stoi mwater Management Control Plan is Required. (Forward to Engineering Department for Review.) FORM ;1' SMCP-70S M kY 2014 ............... __- BUILDING DEPARTMENT- Electrical Inspector x.' TOWN OF SOUTHOLD Town Hall Annex- 54375 Main Road - PO Box 1179 - Southold, New York 11971-0959 ' Telephone (631) 765-1802 - FAX (631) 765-9502 ro southoldtownn ov seand@southoldtownpy.gov APILI:CATtON FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date, 8/20/20 Company blame: lGreenLogic LL Name: Robert-Skypala License No.: 43858-ME email: Barbara@Greenlogic.com Address: 97 North Sea Road, Southampton, NY 11968 phone,No,: 631-771-5152 JOB SITE INFORMATION (All Information Required) Name: Alex Friedman/Erica Tannebaum Address; 350 Macdonald Road; Laurel, NY 11948 - 3 Cross Street: Peconic Bay Boulevard Phone Na.: 716-572-4741 SIdg.Permit#: t-( _ email: Tax Map District: 1000 Section; 145 _ Block: 4 Lot: 14.1 ORIEF D-8 IPT�ON.OF WORK(Please Print Clearly) Roof mounted solar electric system (35)'SunPower SPR-320-327-E-AC.modules, (35) SunPower SPR-320-327-E-AC inverters, (1)_SunPower monitor PVS6 System Size: 11.445kW Circle all That App�I.y. Is job ready for inspection?: YES NO Rough In F5nal Do you need a Temp Certificate?: YES NO Issued On Terre Inf6rmatlon: (All information required) Service Size 1 Ph 3 Ph Size:, #Meters Old Metes#; ; New Service- Fire.Reconnect-Flood Reconnect-Service Reconnected -Underground--Overhead , #Unc!'erground Laterals 1 2 H Frame Pale Work done on Service? Y N Acfditiriri�l (ni'ormatiorir ,PAYMENT DUE WITH APPLICATIONr Request for Inspection FormAs PERMIT# Address: Switches Outlets GFI's Surface Sconces HH's LIC Lts Fans Fridge HW Exhaust Oven Dryer Smokes DW Service Carbon Micro Generator Combo Cooktop Transfer AC AH Mini r Special: l Comments: 1 r � GRENLOGIC° ENERGY August 20, 2020 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Please find attached a building permit application on behalf of Alex Friedman who has engaged us to install a roof mounted solar photovoltaic(PV) electric system located at 350 Macdonald Road, Laurel, NY. In connection with this application, please find attached: • Building Permit application • Owner Authorization • Consent to Inspection • A Storm Water Assessment Run-off Form D • Certificate of Occupancy Application I� D • Floodplain Development Permit Application • Application for Electrical Inspection AUG 2 6 2020 • 2 Surveys of the Premises • 4 Engineer's Reports BUILDrK0 DEPT. • 2 Three Line Electrical Drawings T01,71,11 C-0 ,�T17HOLD • 2 Spec.sheets of the solar panels • 2 Spec. sheets for Racking System • 2 Spec. sheets for Monitoring System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$300($50 Building Permit/$50 CO/$100 Electrical Inspection/$100 Floodplain) Please let us know if you need anything else in connection with this application. Yours truly, Xwdfa m ewcioUac Barbara Casciotta Account Manager GREENRA'al www.Glre�n�oQcrcom Tel 6317715152 Fax: 631.771.5156 631-77 -5152 ext. 1 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S. Service Rd.,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 GREE 9LOGIC® ENERGY December 4, 2020 The Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Re: Building Permit No. 45184 Alex Friedman 350 Macdonalds Rd, Laurel To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced address. Please let me know if you have any questions about the installation. Sincerely, 53anPravw eaac&1tal: Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 GREENLOGIC LLC ® www.GreenLogic com Tel. 631.771 5152 Fax: 631.771 5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd.,Suite 3 200 S Service Rd ,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 ........... R a v V., Suffolk County Executive's Office of Consumer Affairs VETERANS MEMORIAL HIGHWAY HAUPPAUGE,NEWYORK 11788 .......... ............... ------------------- SUFFOLK COUNTY .. . ........ .... Home Improvement Contractor License This is to certifv that MARC A CLEAN fl r doing business as GREEN LOGIC LLC having furnished the requirements set forth in accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk, State of New York is hereby licensed to conduct business as a HOME IMPROVEMENT CONTRACTOR,in the County of Suffolk. Additional Businesses NOT VALID WITHOUT D)EPARTMENTAL SEAL AND A CURRENT CONSUNiElk AFTAIRS ID CARD Director A PICA "A 01 ........... 1 Suffolk County Executive's Office of Consumer Affairs VETERANS MEMORIAL HIGHWAY * HAUPPAUGE, NEW YORK 11788 DATE ISSUED: 12/10/2007 No. 43858-ME SUFFOLK COUNTY Master Electrician License This is to certify that ROBERT 3 SKYPALA doing business as GREENLOGIC LLC - 1 having given satisfactory evidence of competency, is hereby licensed as MASTER ELECTRICIAN in accordance with and subject to the provisions of applicable laws, rules and regulations of the County of Suffolk, State of New York. Additional Businesses NOT VALID WITHOUT DEPAR rMfENTAL SEAL ANDA'CURRENT CONSUMER AFFAIRS '• 11)CARD a Director - ---- ------ -- -- -- - aco CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DDmmr) 01/28/2020 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Nicholas Zulkofske Brookhaven Agency,Inc. PHONE 631 941-4113 FAX 631 941-4405 128 Old Town Road,Suite C E-MAIL . Certificates@ brookhavena enc .com P.O.Box 850 INSURERS AFFORDING COVERAGE NAIC p East Setauket NY 11733 INSURER A: Southwest Marine&General Insurance Co. INSURED INSURER B: Merchants Preferred Insurance Co. GreenLogic,LLC INSURER C: First Rehab Life Insurance Co. 97 North Sea Rd,Suite 3 INSURER D. National Liability&Fire Insurance Co. Southampton NY 11968 INSURER E: AGCS Marine Insurance Co. INSURER F• COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A CLAIMS-MADE XI OCCUR DAMAGE TO RENTED $100,000 X Contractual Liability X X OL202000012922 01/3112020 01/31/2021 MED EXP(Any oneperson) $5,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $2,000,000 POLICY[j]JE0 F-1 LOC PRODUCTS-COMP/OP AGG s2,000,00 OTHER E&O Liability $1,000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $190009000 B X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED X X CAP1043565 08MI12019 08/1112020 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS X HIRED X NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY $ X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ A EXCESS UAB CLAIMS-MADE X AGGREGATE $ DED I I RETENTION O $ WORKERS COMPENSATION X PER'TATTF IIT OTH- AND EMPLOYERSIA 'LBILITY ANY PROPRIETOR/PARTNER/EXECUTIVE Y/❑N N/A V9WCO23041 06115/2019 06/15/2020 E L EACH ACCIDENT $1,000,000 D OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E L DISEASE-EA EMPLOYEE $1,000,000 DEasSCdescribe under RIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $1,000,000 C NYS Disability 0251202 04111/19 04111/20 Statutory Limits E Installation Floater/Property SML93076366 4/15119 4115/20 $250,000 $1000 Ded DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Certificate holder is also named as Additional Insured. CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <NSZ> @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD NEWOi"Itens5 CERTIFICATE OF `$TATE Bo>Ira ensatlon BoardNYS WORKERS' COMPENSATION INSURANCE COVERAGE 1a.Legal Name&Address of Insured(use street address only) 1b.Business Telephone Number of Insured Greenlogic LLC, 631-771-5152 97 North Sea Rd,Suite 3 1c.NYS Unemployment Insurance Employer Registration Number of South Hampton,NY 11968 Insured Work Location of Insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in 11few York State i.e.,a Wrap-Up Policy) Number 203801194 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as'the Certificate Holder) United Wisconsin Insurance Company Town of Southold Building r3epartment 36.Policy Number of Entity Listed in Box"1a" 53095 Rte 25 WC532-00243-020-SZ Southold,NY,11971 3c.Policy effective period 7/23/2020 to 7123/2021 3d_The Proprietor,Partners or Executive Officers are E] included,(Only.check box if all partners/officers included) F1 all excluded or certain partners/officers excluded, This,certifies that the insurance carrier indicated above in box"3"insures the businessreferenced above in box"1a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be Iisted under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The,lnsurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"T. The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the�policy or eliminate the insured from the coverage indicated on this Certificate. (These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",'whichever is earlier. This certificate is issued asa matterof information only and confers no rights upon the certificate holder:This certificate does not amend, extend or alter the coverage afforded by the policy listed„nor does it confer any rights or,responsibilities beyond those containe'd,in the referenced policy. This,,certificate may be used as evidence of a Workers'Compensation contract of insurance only white the underlying policy is in effect. Please Note:.Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a'permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under-penalty of perjury,l certify that I am an authorized representative or licensed agent ofthe insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Alicia-Christiansen (Print na'm f thonzed representative or licensed agent of insurance tamer) Approved by: y (Signature) (Date) Title:Assistant Director of Sales Operations Telephone Number of authorized representative or licensed agent of insurance carrier: 941-306-3077 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) www.wcb.ny.gov \ a I A I / I / I -E3!;?,U5HI5 r PEE<- Al 21302' � 1 1 I \\ 1 I N 53°0331"E WOOD BULKHEAD / I \\\ I I I EXIST BRICK \\\ %/ I ` --_•--_—_--_N''/ I W PATIO \ / EXIST BRICK \\ j PATIO I N H A ISO EXIST WOOD DECK - � o EARTH EXIST I STRY FRAME HO-E LOQ\ T q n '--------------4------------ > ------ _ .\\ / SGS` `r I�-. l \ \ LOT REMAINS OF \\ yK\ FRAME SHED Jy n \ I l A \\ n —_-------------- 113' 520'� \\\ EXIST RA1-1� PROPOSEo( STORY FRAME - MUDROOM HOUSE'A' _ STOOP \ FF-642' EXIST)ERICK WALK__ 315 / U /� 1 ' Imp \ 4 TBACK 0 III ——_ ?7 51 � DECK / � \� EXISTING 2 / 1 \ STORY BUILDING, - EXIST MEGH ROOM e / NEW FLAT ROOF 9 SHOP.=R W/NEW / !Tb ; ZBA APPROVAL BALCONY ABOVE / 1 \ maq / I PROJECT v < I' - \ > PROP P2NY sTORY 1,9 / I \a0o FRIEDMAN 1 PR �/ I RESIDENCE O 1 ae REMOVEEK TO D 6$ ro / _�� 1 350 MACDONALD ROAD FROPosED 2ND _ - '- ,.- - MATTITUCK,NY 11948 - I FLOOR 1 BALCONY / y , -.ort�co,wome�i DRAWING TITLE. SITE PLAN T-5 51°07'00°W 1\ Tl 1 ( \ ET \\ PAGE OIL S STONE ROADWAY A-200 51TE PLAN scaLE,Ib.lo-o APPROVED AS NOTED DATE: xx ma.P.# FEE: 611M BY- NOTIFY BUILDING DEPARTMENT AT '765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH"--FRAMING & PLUMBING 3 INSULATION 4. FINAL - CONSTRUCTION MUST ELECTRICAL BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE INSPECTION REQUIRED REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF SOU 1 H0Lr'TOWl"bWI *-BQARD lKWD Z ONEA S COMY WlTH 4>AMER 148 soum va Ctw OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY t _ Pacifico Engineering — ___ Engineering Consulting 700 Lakeland Ave, Suite 2B P ��[, Ph.631-988-0000 Bohemia, NY 11716 1 t Gc solar@pacificoengineering.com July 27,2020 -- Town of Southold Building Department 54375 Route 25, P 0. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Alex Friedman 350 Macdonald Road Laurel, NY 11948 1 have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system The units are to be installed in accordance with the manufacturer's Installation instructions. I have determined that the installation will meet the requirements of the 2020 Residential Code of New York State and ASCE7-16 when installed in accordance with the manufacturer's instructions. Roof Section A Mean roof height 22.0 ft Pitch 4 degrees Roof rafter 2x12 Rafter spacing 16 Inch on center Reflected roof rafter span 11.7 ft Table R802.5.1(1)max allowable 23.9 ft The climactic and load information is below: Ground Wind Live Load, CLIMACTIC AND Point GEOGRAPHIC DESIGN Exposure Snow Speed,3 Pnet per pullout Fastener Type Category Load,Pg, sec gust, ASCE 7, CRITERIA psf mph psf load,Ib Roof Section A C 20 130 A6 239 (2)5"&(6)3"#14-13 DP1 concealer screws Al Weight DistributionOF array dead load 3.5 psf :'�'`o �pH PiQCZ 0 load per attachment 32.2 lb The subject roof has 1 layer of shingles. Panels mounted flush to roof no higher than 6 inches above roof surface f Ralph Pacifico, PE Professional Engineer �® 0661r3� Ralp �r om a der NY 066182/ \� 6 1 FL 87297 GREENLOGICO ENERGY GreenLogic,LLC Approved Friedman,Alex 350 Macdonald Road Laurel,NY 11948 Surface#A: Total System Size: 11.445kW 1 circuit of 12 on a 20A breaker 1 circuit of 11 on a 20A breaker 1 circuit of 12 on a 20A breaker Azimuth:247° Pitch:4° Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array.25'10"X 24'4 3/4" Surface:26'10"X 27'6" Magic#:Invisimount Legend: ® 35 SunPower 327W Panels ® SunPower Invisimount Rail • 60 Eco-Fasten Fast Feet B 2x12"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: Qr N� � � Y C7 C I r �100� SIOXA Drawn By:MA Drawing#1 of 5 Date:7/15/2020 REV:A _- Drawing Scale: 1/4"=1.0' VAR ENERGY- GreenLogic,LLC Approved Friedman,Alex 350 Macdonald Road Laurel,NY 11948 \�__ Surface#A: 5' `t �' `'s' ' `• ' `� Total 1 circuit of 12 on a 20A breaker 1 circuit of 11 on a 20A breaker 1 circuit of 12 on a 20A breaker Azimuth:247* Pitch:4' M PIA1=1 No W RKAE E E fr Monitoring SunPower CE MINI Array:25'10"X 24'4 3/4" .000, 0, IN, =1 OF 35 SunPower 327W Panels 1►��\_�_ ;fir\►� ��►$��\►:��\I ./ Eco-Fasten 2x12"Douglas Fir Rafter 16"0. Notes- VIN-111, --- _-- - - - Number of Roof Layers:I Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: 914 PA Cr OWN MIAW -0 6182 • 0' Drawing----------------------------------------------------- 2 of ._ 7/15/2020 Drawing 1 (3�GREENLOGICO ENERGY GreenLogia,LLC Approved Friedman,Alex 350 Macdonald Road Laurel,NY 11948 Surface#A: Total System Size-11.445kW 1 circuit of 12 on a 20A breaker 1 circuit of 11 on a 20A breaker 1 circuit of 12 on a 20A breaker Azimuth:247° Pitch:4° Monitoring System: Z5 SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC CO Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:25'10"X 24'4 3/4" Surface.26'10"X 27'6" Magic#:Inwsimount Legend: a CO ® 35 SunPower 327W Panels ® SunPower Invisimount Rad • 60 Eco-Fasten Fast Feet 8 2x12"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: ®� N &4 PAc®��® , i `'v�'OL�` 06c�6182 Drawn By:MA Drawing#3 of 5 Date:7/15/2020 REV:A Drawing Scale: 1/4"=1.0' No Vent Pipes Will Be Covered By The Solar Array GREENS GIC° LEGEND: UP ENERGY AR -Access roof per R202 definitions RAP -Roof access point-to be away from RWV -Roof with valley, GreenLogfo,LLC Approved overhead obstructions,doors, 18"minimum from valley Friedman,Alex windows,decks,fences,landscaping 350 Macdonald Road GA -Ground access area per R324.7.3 width AP -Access Pathway,36"minimum SVO -Smoke vent operation per Laurel,NY 11948 to be same as AP as measured at eave width per R324.7.4 and R324.7.5 R324.7.7,18"minimum from ridge Total System Size:11.445kW 1 circuit of 12 on a 20A breaker 1 circuit of 11 on a 20A breaker 1 circuit of 12 on a 20A breaker Azimuth: 157° Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:24'4 3/4"X 25'10" Surface:64'8"X 44'2" Magic#:Invisimount Legend: ® 35 SunPower 327W Panels ® SunPower Invisimount Rail • 60 Eco-Fasten Fast Feet 8 2x12"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" A744 X X7 74 Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: 35 SunPower OF N��✓ 327W Panels ?" P'�C/X, .� ��� Meter O FA- Drawn By:MA Drawing#4 of 5 Date:7/15/2020 REV:A Drawing Scale:3/32"=1.0' ENERGY GreenLogic,LLC Approved Friedman,Alex 350 Macdonald Road JCB1ATERM19 Laurel,NY 11948 Total System Size: 11.445kW 1 circuit of 12 on a 20A breaker -- — — 1 circuit of 11 on a 20A breaker 1 circuit of 12 on a 20A breaker Azimuth: 157° Iftedd List Qv- MI huffiall Lid Monitoring System: N SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC Em-Fasten"Fast Feee'Base Plate 6D Racking:SunPower Invisimount E00-Faslm"Fast Fed AIUYinImElOdc ® Panel:61.39"X 41.18" Array:24'4 3/4"X 25'10" Em-Fasten"Fast Feet"BIEWasl irg 93 Surface:64'8"X 44'2" M4-W,CPI CaxealerSaeLe w Magic#: Invisimo Legend: M44B 'CPI GamealerSdew 3BJ 35 SunPower 327W Panels ® SunPower Invisimount Rail • 60 Eco-Fasten Fast Feet B B 2x12"Douglas Fir Rafter 16"O.0 Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: F'�E OF NFLy-, CO PA 0 08M2 FESS101A Drawn By:MA Drawing#5 of 5 Date:7/15/2020 REV:A Drawing Scale:3/32"=1.0' ardre�``" � „� � ,".� a, �,= "„"ry{ .�'a,f" >'-°fix;-=.,.�'�""°iz �,x�' ^v'p'`��'>, '.,a; qr e„��"�✓. `F, �:h+,�`:" q, y' Ffi_ � _�"y� � ��gg`�, r'`9-,r .° a�^ a�vdH, _ M°� eR W�. .a^�.s°� ,.x,r✓�4 t:`4r;i,.�'}, yE ,gv� r}i;..,," 4>45.,,^ '� 'f" i£eZ3�"d,a ':/,, ,...,,,,,,> r Cni",/ s �s5'3kv.✓ /' ,� 9`+:E:",,.„'>•e r`Sy r' ,vuu=� � r�� �` �o . v,iFa, „„✓ �yH� P, _ � Y� - ;:r ma.,- ��-� g.,P,-: �'`�.-� ,;;` ' _ " „.�'s�`�,F9ir.o ,.a, � � rr�-a� ge/ry- ��d '-4w•a Via.=. �` ,_ £, �, MIN lr'Prove°`Support, Reduce`Mainceharice Costs SunRower Ener ;yLlni<—Plug-and-Play Installation An.intuitive monitor ing b•:iebsiLe eriayou Lo This complete S011111011 fI resdent al and con-me'tial 1rlor',lor ng and see a visual muo"of customer sites rontr of irclides the SunPov.er"PV S,:oev sor 6(PVS6)which 1 mproves Remctely manage hundreds of saesthe instalarion process,overil system gel ability,and CUStomer Receve.el ective_yst m reports 'XDO t_'ice -,_ccate�ystern•issues-ar�c renictely(,,;rgrose Co'npact fcetpru-t fo-',r arovec aesthetics 7iagnose issuesoniir,e P.obust cloud connectrn;y and corrpr&ensive local connectivity :gill dcwr,for the`s�rus of ind;vidi.ai c:evice: Flexible conrigurarion of dunces donna nstallauon Cc)'1SLr­if.(:hon meter Rede%je-grace producrfon rneterlrg;pen:iing) w Weo-based commissioning Re•rore diagnostics of^VS6 and inverters Durable-UL Tyre 31D,enclosure reduces mairtenance toss w.W EaSy n.egration,nirh SinPo,ver eBOS Add Value for,Custorners Robust Cloud Connectivity s ° W i P,�c'`tiple opt'ons to maintain opt ma` cus:orners can: See what their,solar so„du system prces each � °-',` =�t�'�`� ;ennecrivity ay,month,or yea , Hard�,virec Etnernet Olodmize:heir so ar rrtiestmem-and sa�✓e e i Wi-h ' energy expenses Cellula backup See thelr`erergy use and esti,Y a..ed hili savirias Seethelr solars}•sterr's performance using the S:1nPower mon-cring viebsite of­nobile app � . ,.ter. �, °o, •>a,� �., ., , , ' „°. NEW x:teR"»l.u`tera.� 'mrPNN4v'.aHa * ♦ ! SunPower Monitoring Webs;tes PVS6 SunPower AC Modules _aanusi� � illU _ �l�y� IIBIBIL�III �o .i � ` stzr "h'Cs�' c '4,r( - Multiple communication options include Ethernet,WI-Fi,and cellular ; Number of SunPower AC mcdules 85 temperature -22"F to a"z0°F(-30°C to+601Q supportea per P'.'S5 Humidity(maximum', 95%,non-conaensing Internet access High-speed Internet access a accessible rourer or savi'ch Pawer '00-240 LMAC(I.I 50 o-;z0 I Iz 208 VAC(L-L in 3-phase).60 Ht a RS-485 Inverters and meters • One channel of revenue-g-ade production metering Integrated Metering ® -Iwo rnannels of cons,inI metering weight 5 5 los 1,25 kg; Ethernet- - LAN(or opt'onal WAN)per — -- - - -— Dimensions '18 x 8 0 x 4 2 in (30 5 x 20 5 x 10 a'cm) PLC P_C for SunPower AC mcdules Enclosure rating UL90E Type 3l? VJi-1= 8C2.11 btgFn 2 4 GHz and 5 GHz Ceilulai — LTE(at-V1136 t;MT'i ------ -- ----- ' lig3ee IEEE 802 15 4 MAC,2 46-lz ISM nand Data Storage 5D days Customer site tr okor us sunooweL,corn -- - Jpgrades ru,oma"c firmware upgrades Panne:site p=_ P_m'_s sL'n000.,er ccm Erawsers Flrefox,Safari,and Chrcme Moble devices il"hone".iPao'",and Androic Customer app 1.Create account online at,moritor Ips sunpowe.cem 2 On a mobile device,download the SunPovver Monitoring Warranty 10 year Limited bVarranty app fromApple Apple App Store" Google Pla}%'store 3.Sigr In LS r4 accoun,emi]arc pasTword Cer tiiicatiors I WL,CE,UL 61010-1 and-2,FCC Part 15(Class B) PC 8@11118 iffm FCC 1 D:YAW529027 E503346 U P O 11V E . SunftwerO E-Series: E20-327I El 9-320 S u n Powe rResidential . .r-" p,I, j C Module s Built specifically for use with the SunPower Equinoxn`'system,the only fully integrated solution designed,engineered,and warranted by one ;:- ; x manufacturer. Maximum Power. Minimalist Design. ; `&W Industry-leading effic ency means more power and savings per available space With fewer modules I enured ann h Eden inicroinvertei s,less is tru y More Highest Lifetime Energy and Savings. Designed to deliver 60416 more energy over 25 years In real-world condinors like partial shade and high temperatures.1 fkFndatinent �6yaffererat = a !U to p 60% more lifetime �a< _ ":n °,.5. Wa sy,9�rt''°a„ energy � +`,.''3;�);,x'A aFi^�5; ,•,x $v z+,9'`,rTe:" x .r. ... ° 0 SunPowerIVla'xeonfvSola�'Ce!!._„``r Years of operation ��.'”•°r Enab.es higfies�;e•i cie'no,�'�t�= .v-: �..t,;� s Best Reliability. Best Warranty. },:���®ns�,'n"iutCr~��^Ful±3�'?I It)!)�, � ���'�;��y• '<,;, � aoi`�t saticE�r wetaL �atac7r �' �� 'I With rT7ore tha°7 25 million modules deployed around r' ct° °%',r;.; the world,SunPower technology Is proven to last.Thafs k 1; andrn405 r5;€�y ,,c�: ' F,,V 41 why,,,e stend behlrc our module and—icrolnverter ;vim the Industrys nest 25-year Combined Power anc Droduct Warranty, icluding the highest Power Wa,ranty �x� z`�.,fix+' �»n° '. ..�.." y Ty�{'•gym y� n" actory'ntegrated Mici:,oinverter:,­A,,,? k�.5^-:- "�'>k`"1,•. T'; =c.`v`�k <,,.`a xi: tuAF;`; ':s °°,tSl t1 71 r;4 5t e irs t r r:"21 X25; ` .., ,,, ,.,F�,,•.��� ;;'4�;s��' • ;�';x oIr2lt epre"rte:l�V''krek7'tai-ia?t:rl'1c,-t.aEX12% ,e°,y�>Y&. `� ,<„a`v'� ,,r•z�k'�atr <;<<vz� Wi,": i more k„ Clpld'Slut�s?4vii°,"�:rt.%:�� �"•; .�' ' ,power ,,,„ .��- _ �� s ~ � ._n..;Y �g.Pe '•e�- •_° °y x ° .in year 'hK eG.,vr'`;t,,,j r;t:iCl,LN_e I ' '25 a,.-i:'`,..<;a3i,Lz x�„`N:z>,.;e�`a;,r :4,�,e.''.�`•',::`<�..'.:,at � �.. ,�`;:S,�;w P = +o t; , 75 Years of operation Datasheet E-Series: E20-327 ( El 9-320 Sun'owerl Residential AC Module Inverter Model:Enphase IQ 7XS(IQ7X5-96-ACM-US) @240 VAC @208 VAC ea,p itrtut='a•ae 320`:'A - - - 320../A -- - -- vlar 31,VA N'),rI ;L L;V(,h,)5,f/R.rt;c1;124J/211-)64 2081183-22b f,1a� ��••r•u_u,usr;�t.,ur:�'n.'i(r`•) - - --�31 --- ---------- - ------ 1 1 — ---- - ------------ - -------- '•Y9r:y Ln;s per 120 P,;t 1,t:a-d-C real: '2(s ng e pl-ase) 1 C(novo ocle)wry -- -- -- ------------ ----- ,_. ;ntp i::r�✓Lr Cy o7;4u 97;)% °)')•'a f r,q,,r•nr•/ 60 t1/ r":8 117 A,-Snort C"ant Paw',C:r-e,t rivr�r S:yt es -- -— - - S 3 A,ris - - - ---- •')•<atVt�-:;,,e Class AC Pc't A,-�Ic-t r<r.'I f,,,d; . I^r 1 i mA tC r;>_thvtu 1 (adJ stat e, - - ---- 0%le3c i )7 ag --- - ----- --- - --------- - -------- ------------ - ----—-- ------ No act.r„,hasp c ala=ar ng`c'ct-ee-F`Iase nsta a-Dots SPR-E20-32/-E-A( SPR-r 19-320-E-AC25 veal hrnited pwn,:r vv,a ra'7 y — _ ---_-- _ -- ----------- -- •AarraiWes ZS,=eat 6rnd(>d cr„ewalrarlt' `dl .,rrr Po_nicr'(Pnorn) 327 Vv 320 Vv - ---------- ------ ----- ------ - ------------- oy`r al 51-0% 1103 'tificauons L 17!1,'IEEE-15 _7 e I .do:ale EfP.ercy 20•:,- 19 9°5 •` •,.L 1741 AC P.9adt-'e,Tyne 2 fire ratFci) crd'Pmo (O^rl (POJrPr) -J 3S4;t!°C -G 3; S?"C - ;2109-1 r IEC 6210?-= C r p'Ialtte -CC'3ar1 15:Ic s? `nree brass'-locles CES-300l Clas`,6 Shade-01nt.:gr<>ted,ra;ule'PVC •rlxnnur* ATC-S 2 2 NO 07 1 r odder point t•ack r CA RJ 221(:;L 'SA:` - - - h-d„des bol'iVar and Reactive Power P-Ic-Cy) -• ®®- e •11-_;ted P`:'Rap'c S t..tcomm Eaulpmenr Coe a.I,g'emp -40`I to+IBS'F( -to-o,"C) I,'ax ,`;mhl�ntTtemp "22-C(50"C) - Fna7es rasta'Ianonlrat crrinc;wlin i ------ - --- --- E( 690 r,(,\f_mcc ile) V'n 62 psf;CCG,Pa 3r)S hgl'ar fro-t-&oa:k `.EC 690 12 flap d Sr,tcown Inside arc o,ttslde ti-e an-at) k1ax _oac 6 ( ; - -- S_r,^, 125 DS`.6CC0 Pa 611 tg•'m'-o-- - - s._C 690 15 All Can-ectors,690 33(A)-(EYtI; ; Imoa,-,RestsEance cl (,5 mm;d ameler I-ail at 5%mnr;25 mi=) wr'er 1 sed 1`.'Itn ll7Vlst Nluu•,:'azkin1,,cnC n415.loin cCCe'ssor'es � ®- (UL2;0 ) Scar CeII 90 Manocry.itE lire Iv axeon C,en b; ^Tule grounding a^d ocrding througi mosiMcnunt -- --- ---- ClassAbrerato:: =ront t.Ass -i' n transmiss on temoered lass e<1 t tv ,,,, 3 _ € r• - r qac„a*.i�d Iti 4 AC rnn'11_I Q C,.nIP,and dt:�sscr It>`,,l t 67C-,aid; ant'-re`ecttve coat ngL 4 22338;, Er,,ronmental Rat'rg OUldco' rated "fated`or load breaku,sconnect lays 1 nl �k aro.jl r(hlght"AA','A'<,t ng) „n est - Pcter,al-I^duced deg-acct on free Vde'rllt °2 9 lbs(1);✓�i I 1558 min(bi 31s,) �... l •2erommP'rdPti leiax 1 3 In (33 f ran) i M,)-ule Spasm- ® ; 1 9.npr,,•e,35C,V:camparea to a'on enttnna mcaule or same s zed arrays(260 VVI.16h 1 46 mm efhctent,approx.-ram=),1>5^toreo t>rryper=.tat:tbascr.onr•ur•ipany•^odt,e ttetnr charact=nn;IonandrkiSIm)r: ::yYtlnv:era rarlrr(Cz•npez,6Ze:s Sa0o'rter V able 1;eg'adat on Rath,'Stir,�o'.r, r v hie ower?019• 7Rasedon,.•artIiciv,h i-s ft ornw, ze,oftor)'Crnt r.)fa•:.atars;crI1S,asof 1c,wmm •--- Jnnt.a'y7u17 (477m) w..30 rnm-.y„ 3.-'ra-,kIn'Flat.n9o'c0V1,L•aL tytnl;3'V=•for,ular?atria,•,Parti PVTarh°omr (ttm) FY�gszlne 7015(`ampea.),Z etal'SuiPowor.Aoiule-)egradatlonRate,"i rPcvrcrw'iI[e par:•r.2013 I I 4Facwrrset ro F47a-•Lr-4ce'aul;set,ngs Cz,RtlP21.1efzuk!x-'ergs) 3t e;ct'lurtng 393 mm rommsS1cr•lig See^neEquinor•tstallattcnG,tce=-WC1'or moretofcrmat-I (15 Sin) ? l SStanderdTesrC=ridlt'on�(i ,r(-AYTn'I•iadtince,At_+'„2VC)NRN cslt,r_;er t - stanrd SCSNISrutrent P-CCSFFzndvoltagv r ,.� IID,-Voltage sf;alyc'untairecvel:htrthe _ mo=dule f''tts pros Ilrt Is 11t t IS*ec as pVRSr arc.ronlrr mr wlrl-torr 7014 ano N=C?) 7 Gut',12, ,„,., 431 min •,,,�, ant,C17 i-7�7;Rt11r r.=-715 R=;,ui ihutrlo:•vn rt�V S}�,eons,f^r AC ar ri p'^r,-;lu:to^,, (nzlnl ,=when trstalted ac.nrdu-�to marn)fart t,•eI;InCb t_Lt ons z.tENIT Q�, Gur. Vn111 See;:^JIrS 5t 1'ipowe•cwn,``dtts,fc!n"o•Y_r efe=erCe wfet rnatiun PYFcr=^ot:de,atts,sec exterc•cd data3hee_,wry s,lr�av:c`com/datas-ecs r0''I' Saecl'rcat w=utncludeoit,°rtlsdatasytee'_.=resu6;eaxchangeu•Ithout no,-e LISTED Ea7-a x2015 SunPowe,Corporduon A I R,hts Reserved SL,,PCVJEI,.ne Module t re Fedarmaxe Type 2 SUN OWER SU IN POWER lcgo inci NIAXEC4 e I e registered tradernarks,of SunPoVw.- Corocr.nLn Ii,itis U S and o-J,&countries as well -8a0-SL t.PGW'--k Ple3,v I;'at,tho•wireW'i ,I•t n>tal auon lns,Du,t nn,int t,,•taI s 531948 RevA •® • �'A rr Q ° . o d' x n ,- F c �&^Si-e r ^S Y•a.. �7"� All Vlt ® ® ® ® ® ® a Simple and Fast Installationa� � ° [ntegrated module-.o-rail grouncng i - • Pre=assemh{eri mrd anc end camas Levitating mid clamp For easy placernent 4 Mia clamp,,vidth raCditaLPS consistent,even Friodu;espacing Simple,pre-rrdl^d rad splice 2703 Listed ntegrated grounoing Flexible Design , �� ' Addres�,os ncz.rly all sFoocd res deur iaF roofs Design it landscape ant•:por,°a;,, Flails eral,le easy obstacle rnanager-cn, _ Customer-Preferred Aesthetics _ m _ nodule and#, mcunGng aesthetics Bes;-in-class system aesthetics Flegant Simplicity Premium,lora-profle desigr Dack anodizes components SunPower," InvisiMOUntTM is a SunPower-designed I idden m!d clamps and end camps rail-based mount ng system The InvisiMount system and capped,flush rat's addresses r esider.Lia- sloped roofs and combines faster Part of Superior System installation time, design flexibility,and superior aesthetics. • Burlt for use kvitrn SunPower DC and AC modules Che invislMount prodt.icr was spec fically envisioned and Be.,;,-ir-class.rysten-reiianility and aestherres comoinew,thSunPovver--nodr.iesand engineered to pair with SunPower modules. The resulting monitoring app' -iesystem level approach will amplify tiaesthetic and instal,ation benefiis for both homeowners and installers. ANN— a � ` � sunpower.com "n" pm-- 4" .°P q1' OD L mt NiodU e"I'Mid Clomp o^d Ro .,Icdule*I End Clamp and Rol Wi ti id Oarnp End Chrr-p Raj,K Ra Splwe G,ound Lug Asserroly End C,,TP M O'd m -0 Tempe,-ature 40-C to 90-C 40'>=to 19/' Component, [V�terial i We,h- 3000 Pa jpl ft 0 111-D' Max '-Oaca Miti,Clump Biack oxine srainless steel AlSl 3046000'�a-1coirforce ; 63 g�2 2 oz) End Clamp Blac,<anoch2ed aluminum alloy 606:3-T5 lic"g( ssoz) Rail Black anodized ai-irninurn alloy-,()O!)-T()1830-/r-.(9 oz-10 Rail Splice Aluminum aho,,6305-TS f 830 Yrr(9 oz:ft) 25-rear prodUCtwarranty 'Alarracties Grouod Lug 304 stain;ess Ass--n,uly 1 CC,5 g/rn(3 71,o;) S-year fi-isrivjarranty (A2-70 bolt ,m-plateci copper 11.1g) EndCarB'ack acetal 1,PON11)-copo,-y-rrer 1 C.4 g lO 37 UL 2733 Listed -w-NOW I 'D Class A Fire Ra-.Pd A Compo,tion Sfwigle Rafter ALtachrr-rt Compos-oonRoct Dec wg Attachment a AnpbcaZiori Cured and,-iatTi`lc:RjoFA,,tac-orient Uri vcrsal interface lo,0:her Ro(-)f Attachments I Wei to roof attachment hardk,%.at e manufauver's cloc,,mentario- -im,wih, r�-,e tea.is ampar-olewh Ll,v Inv sirV.xjnt syitvrn-vquiie•i for ha-*,,,e mtera.pp,abihty sunpime!corn Docurnent#509506 RevC i _ NEW EQUIPMENT FXI STING SFIRVICF 120/240, IPP, 3W PV—SA-1 i 'a 200A P4 VH I N . : . 1 . a Mf e V AC—COMBINER PANEL i PV—SA-2 AC-CMB-1 [ (PV LCADS ONLY) � AC DISCONNECT • . s M n AC—DSC-1 t ( a e a _ I a e v PJ—SA-3 A) BSP-' 9 ► • • ® ® tx ( MAIN 9KR-2 IV B 8 8 FUSED k 8 N �K - EGC 11 N I N EGC [ EXiS-IN 3 AC PANEL ! ( [ L GEC (EXISTING'�' ____.. .._ GEC IRREVERSOLE SPLICE & CU PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Friedman, Alexander __,kmsGREENLOGICO .350 Macdonald Road ENERGY • Laurel, NY 11948 ELIMINATING THE COST OF'ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Friedman-3LD1 Revision: 1 Revised: 7/2/20 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PV SUB-ARRAY SPR-E20-327-E-AC ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 11-MODULES PV-SA-2 PV SUB-ARRAY SPR-E20-327-E-AC EN PHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 12-MODULES PV-SA-3 PV SUB-ARRAY SPR-E20-327-E-AC EN PHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 12-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX. AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 3597 WATTS 211-264 VAC 14.63 A AC 240 V,AC PV-SA-2 3924 WATTS 211-264 VAC 15.96 A AC 240 V,AC PV-SA-3 3924 WATTS 211-264 VAC 15.96 A AC 240 PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Friedman, AlexanderGREENLOGIC — -350-Macdonald- Road ENERGY Laurel, NY 11948 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION =Wage 2 of 3 Drawing No: Friedman-3LD1 Revision: 1 Revised: 7/2/20 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMB-1 AC COMBINER PANEL 25OV, 100A, NEMA-1, 1-PH, 3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 25OV, 60A, NEMA-1, FUSED; FUSE RATING: 50 CONDUCTOR SCHEDULE TAG TYPE - CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 1-1/2" PVC-40 4 / 4 C THWN-2 1-1/2" EMT 4 / 4 1.) CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUITTO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC-AND LOCAL CODE REQUIREMENTS. 4.) NOTE: GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER MINIMUM. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Friedman, Alexander � GREENLOGICO .350 Macdonald Road �° � � ENERGY Laurel, NY 11948 ELIMINATING TETE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Friedman-3LD1 Revision: 1 Revised: 7/2/20