Loading...
HomeMy WebLinkAbout45185-Z �4�OgUFf®CCQ� Town of Southold 12/16/2020 P.O.Box 1179 53095 Main Rd Al Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41691 Date: 12/16/2020 THIS CERTIFIES that the building GENERATOR Location of Property: 3925 Soundview Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 94.-3-1.10 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/26/2020 pursuant to which Building Permit No. 45185 dated 9/9/2020 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: accessory generator as applied for. The certificate is issued to Lissner, Samuel&Rebecca of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45185 12/9/2020 PLUMBERS CERTIFICATION DATED A ed Signature �SUF�n K� TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o • SOUTHOLD, NY mol *! 410 BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45185 Date: 9/9/2020 Permission is hereby granted to: Smith, Diane 21 Laurel Ln Matinecock, NY 11560 To: install an accessory generator as applied for. At premises located at: 3925 Soundview Ave, Mattituck SCTM #473889 Sec/Block/Lot# 94.-3-1.10 Pursuant to application dated 8/26/2020 and approved by the Building Inspector. To expire on 3111/2022. Fees: ACCESSORY $100.00 CO-ACCESSORY BUILDING $50.00 CTRIC $85.00 r Total: $235.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building_. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. 8.19.20 NEW New Construction:GENRATOR Old or Pre-existing Building: (check one) Location of Property: 3925 SOUNDVIEW RD. MATTITUCK House No. Street Hamlet Owner or Owners of Property: SAMUEL LISSNER Suffolk County Tax Map No 1000,Section 94 Block 03 Lot 1.10 Subdivision (tee Filed Map. Lot: Permit No. LS J Date of Permit. Applicant: JASON FAY (AGENT) SAMUEL LISSNER(OWNER) Health Dept.Approval: N/A Underwriters Approval: Planning Board Approval: N/A Request for: Temporary Certificate Final Certificate: X (check one) Fee Submitted: $ qLAJ Applic t Signa e e Building Department Application AUTHORIZATION (Where.the Applicant is not the Owner) 1,Sq V14y� �1 Ss(1 Q� residing at ?C 02 by I F 0 tl V (Print property owner's name) (Mailing Address) -TT 11-0 C)C 1,J`j do hereby authorize �Q Sail rq �i l a �oL (Agent) to apply on my behalf to the Southold Building Department. (Owner's Signature) (Date) �2Wc Zfslr&xel� (Print Owner's Name) oE so�r�®� Town Hall Annex ~ ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 sean.devlin(cD-town.southold.ny.us Southold,NY 11971-0959 QUO, BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To Samuel Lissner Address: 3925 Soundview Ave city.Mattituck st: NY zip: 11952 Building Permit#: 45185 Section: 94 Block 3 Lot: 1.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA. Neal Coleman Electric Inc License No: 4728ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Commerical Outdoor X 1st Floor Generator X New X Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 30kW Kohler Generator w/200A Whole House Transfer Switch Notes Generator Inspector Signature: �,�- Q Date: December 9, 2020 S Devlin-Cert Electrical Compliance Form As Of SO(/lyo � 07-7 dl 2-5 '30-t/`' - vi e-,,VRj— — # # TOWN OF SOUTHOLD BUILDING DEPT. o`y�ou�n 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ' ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ]' FIREPLACE & CHIMNEY ` [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH). ELECTRICAL (FINAL) ( ] CODE VIOLATION [ ] PRE C/O REMARKS: �,y DATE I - �l - INSPECTOR i FIELD-INSPECTION REPORT DATE COAZIENTS FOUNDATION(IST) FOUNDATION(ZND) UN in ROUGH FRAMING& kP 1 PLUMBING y i INSULATION PER N.Y. y STATE ENERGY CODE i FINAL v' - fox d ADII C 0a-Z- 00 Mi b H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX: (631)765-9502 �( � J � Survey Southoldtownny.gov PERMIT NO. ( J Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined 20 Single&Separate Truss Identification Form Z Storm-Water Assessment Form \ Contact: Approved 20V Mail to: ( IJ Disapproved Phone: Expiration ,20 ILL 10 j ": �+Q O��IICI Ilflli Buil m sp or APPLICATION FOR BUILDING PERMIT ME 9 z 9nd Date August 26 ,20 20 INSTRUCTIONS tG ` i XA�lili=l T a completely filled in by typewriter or in ink and submitted to the Building Inspector ector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) 177 N. 10th Street Suite F,Brooklyn NY 11211 (Mailing address of applicant) State whether applicant is owner, lessee,agent,architect,engineer, general contractor, electrician,plumber or builder AGENT Name of owner of premises Samuel Lissner+Rebecca (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. 4728E Other Trade's License No. 1. Location of land on which proposed work will be done: 3925 Soundview Rd. Mattituck House Number Street Hamlet County Tax Map No. 1000 Section 94 Block 03 Lot 1.10 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Residential b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work New Generator (Description) 4. Estimated Cost $7,000 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units 1 Number of dwelling units on each floor If garage, number of cars 2 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures,if any: Front 81.4' Rear 81.4' Depth 30.9' Height 32'± Number of Stories 2 Dimensions of same structure with alterations or additions: Front NA Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front NA Rear Depth Height Number of Stories 9. Size of lot:Front 154.92' Rear 150.42' Depth 581.87' 10. Date of Purchase 6.19.2020 Name of Former Owner Diane Smith 11. Zone or use district in which premises are situated R8 12. Does proposed construction violate any zoning law,ordinance or regulation?YES NO X 13.Will lot be re-graded?YES NO X Will excess fill be removed from premises?YES NO Samuel Lissner+ 3925 Soundview Rd. 1.201.306.6939 14.Names of Owner of premises Rebecca Friedman Address Mattituck NY Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES X NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland? * YES X NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect,to this property? * YES NO X * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF,SUfi Jason Fay being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Agent (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before mthis e _day of —20X Notary Publ' TRACEY L. DWYER Signa a of A plicant NOTARY PUBLIC,STATE OF NEW YORK NO.o1MM"� ,� QUALIFIED IN^k I '-UL&COUNTY rl— COMMISSION EXPIRES JUNE 30,429 :f °��fFpt ;a�T BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD s Town Hall Annex- 54375 Main Road - PO Box 1179 f ff Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 v, rogerr ,southoldtownny.gov— seand@southoldtownny.gov, i APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: 8.19.20 Company Name: NEAL COLEMAN ELICTRIC INC. i Name: HEAL COLEMAN License No.: 4728E email: neal@nealcolemanelectic.com Address: PO BOX 514 MANORVILLE,NY 11949 Phone No.: 631.369.7239 JOB SITE INFORMATION (All Information Required) Name: SAMUEL LISSNER(OWNER)/JASON FAY(AGENT) Address: 3925 SOUNDVIEW RD. MATTITUCK NY 11952 Cross Street: Phone No.: 347.463.3168 Bldg.Permit#: email: jason@readestreetstudio.com� Tax Map District: 1000 Section: 94 Block: 03 Lot: 1.10 BRIEF DESCRIPTION OF WORK (Please Print Clearly) INSTALLATION OF NEW GENERATOR Circle All That Apply: Is job ready for inspection?: YES/®O Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected- Underground-Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection FormAs Y t f, t 1 BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex-54375 Main Road- PO Box 1179 Southold New York 11971-0959 ` Telephone 631 765-1802- FAX 631 765-9502 rose outholdtownny.go, seand&southoldfownny.aov APPLICATION FOR ELECTRICAL INSPECTIQN ELECTRICIAN-INFORMATION (Au lnformadon Required) Date: 8.19.20 Company Name: NEAL COLEMAN ELICTRIC INC. Name: A COLEMAN License No.: 4728E email: nea19nealcolemanelectic.com Address:, PO,BOX 514 MANORVILLE NY 11949 Phone No.: 631.369.7239 JOB SITE INFORMATION (All Information Required) << Name:; SA1VtLTEL LISSNER(OWNER)LJASON FAY(AGENT).. == ---- -------- ----.._,.._ Address: 3925 SOj=VIEW RD. MATTPTUCK NY 11952 ;— Cross Street: :Y Phone No.: 347.463.3 168 - - - - - - - - B1dg.Permit#: Y.S email: jason@readestmetstudio.com A =Tax Ma .District:-. 1 00 _tSection:_94._._ _ __ _ __ _ Block. 03-_ BRIEF DESCRIPTION-OF WORK(Please Print Clearly) <_ Circle All That Apply: ' Is job ready for inspection?: YES/® Rough In Final Do you need a Temp Certificate?: YES/ NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# PA`s New Service- Fire Reconnect-Flood Reconnect-Service Reconnected-Underground-Overhead Underground Laterals 1 2 H Frame Pole Work done on Service? Y N t Additional-Information';, -PAYMENT-DUE,WITH,APP,UCATION Request for inspection FormAs , TS PERMIT# Address: Switches Outlets GFI's Surface Sconces H H's UC Lts Fans Fridge HW Exhaust Oven Dryer —Smokes----� _--_.� ��., -- ---_••3e rIc-e-- Carbon Micro Generator Combo Cooktop Transfer AC AH Mini Special: Comments- E.� N 58123'36'E LONG ISLAND SOUND — N 60106'07"E E LINE t MEAN HIGH WATER MARK MAY 78.2= 70EOFBLUFF w GENERATOR LOCATION DIAGRAM w 3925 SOUNDVIEW RD M MATITUCK NY LL TOWN OF SOUTHOLD 1e�JCC / U9 SUFFOLK COUNTY, NEW YORK p `r G °�F w! S.C. TAX No. 1000-94-03-1.10 �p �' �' � � r � SCALE 1"=40" 'N- NO �Qb�• >� �� v �� MAY 28, 2020 TOTAL LOT AREA =91,376 sq.ft. 2.097 ac ®� WOOD DECI W" c LL o� w � !I 0:) AS N01TED �� €1ATE.. Z�, B.P.�f vxC� FEE: _ G,v• e WDGD NOT BUfLDII�'C) i '?,=ri'II�iEN AT LANDING Vol 765-1302 8 Aid TO 4 P,,I FOR THE FOLLOWING INSPECTIONS: L,,pQ! Y p153" 1. FOUNDATION - TWO REQUIRED QpF i t�E 05�ON SaE6 w LL FOR POURED CONCRETE g(P D m 2. ROUGH - FRAMING & PLUMBING DQ ' < 3. INSULATION p1P � tP U 4. FINAL - C0I,ISTRUC`f iOfV MUST g BE COMPLETE FOR CO. m CONC APRON �p ALL CONSTRUCTION SHALL MEET THE /w WROUGHT IRON FENCE s o REQUIREMENTS OF THE CODES OF NEIN 94' T=r BRICK f YORK STATE. NOT RESPONSIBLE FOR W DECK DESIGN OR CONSTRUCTION ERRORS. INGROUND POOL 25'-0"ACCESSORY SETBACK POOL NEATER srEPs I COMPLY OIC PLY WITH ALL CODIES OF �>O,yF ROUGHT IRON FENCE NEW YORK STATE & TOWN CODES WNEW GENERATOR+ AS REQUIRED AN D' T.(OIVS OF H WELL BRICK WALK BRICK BRICK CONCRETE PAD(4'011 X 8'61') LL 378 ; 2<D STEPS b �,, b STEPS SOUTHOLD TOWN Z BELGIUM BLOCK 23 15 B' ` Er m CURBING N 1&2,S ORY FRAMES'-gyp° SOUTHOLD N PLANNING BOARD m FJOIfSE GARAGE r rn ASPHALT DR�WAY - N SOU LD TOWN TRUSTEES 309' iN 122' ❑ ONE WALL x'14 0' 452, ❑ 012 oSLATE �B' N.''S.DEC LANDINGS ; ' x 0¢ Z Z /o' - rc0 �CIAP LTER QooQ _OO� ,�} -On w MClSLATE > DO Z O z ❑❑ WALK -> O J �y� m eflOt�M C �e B<OO iq CID 0 OG v STONE 98iy I N o a� WnLL G Z UTILITY POLE NEW 1000 GAL TANK NYT S73 3 0 r o z a x � � A U m Y y O V < H E � D � 1 o m m N �+ N O R UU w m 3 LL ¢ U- w d w Q 0 o U UTILITY POLE m NYT 57-2 BELGIUM BLOCK CURBING Z ASPHALT ORNEWAY ,'y w 3 p v3 w z BELGIUM BLOCK CURBING a 0 y 335 W � 3 t cl) ._-•'••••• .: CONC MON. 5710850"W "' $ N 193 72' 208 72' w N O MON CR c? � Go N �9FE m N U") 154 g2 0 LL GATE N UTILITY POLE 49.5'WIDE RIGHT OF WAY PIPE 4915220 W 49 5'NppE RIGHT Of AY W _ w RHEPD CONC MON 199.78' 2$ i Y • n L9 3' RNE`NP 1g420. S 5708'50"W 154.5T LOT O s asti5xZ0 r nNSERVAT'ON SUBDMION FOR 0 KOHLER. Model: 24 RC L Multi-Fuel Natural Gas/LPG 09001 Standard Features 4 KOHLER, • Kohler Co.provides one-source responsibility for the NATIONALLY REGISTERED generating system and accessories. • The generator set and its components are prototype-tested, factory-built,and production-tested. • The generator set accepts rated load in one step. • A standard five-year or 2000 hour limited warranty covers all k, ggEgggg systems and components, • Quick-ship(QS)models with selected features are available. See your Kohler distributor for details. • Meets 291 kph(181 mph)wind load rating. • RDC2 Controller �� ! o One digital controller manages both the generator set and transfer switch functions(with optional Model RXT transfer switch). o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to varying household demand. The Kohler®Advantage c Digital voltage regulation protects your valuable electronics from harmonic distortion and unstable power • High Quality Power quality. Kohler home generators provide advanced voltage and o Two-line,backlit LCD screen is easy to read in all lighting frequency regulation along with ultra-low levels of conditions,including direct sunlight and low light. harmonic distortion for excellent generator power quality to • Engine Features protect your valuable electronics. o Powerful and reliable 2.2 L liquid-cooled engine • Extraordinary Reliability o Electronic engine management system. Kohler is known for extraordinary reliability and o Simple field conversion between natural gas and LPG performance and backs that up with a premium five-year or fuels while maintaining emission certification. 2000 hour limited warranty. • Innovative Cooling System o Electronically controlled fan speeds minimize generator • All-Aluminum Sound Enclosure set sound signature. • Quiet Operation • Certifications Kohler home generators provide quiet,neighborhood- o The 60 Hz generator set engine is certified by the friendly performance. Environmental Protection Agency(EPA)to conform to the New Source Performance Standard(NSPS)for stationary spark-ignited emissions. o UL 2200/cUL listing is available(60 Hz only). o CSA certification is available(60 Hz only). o Accepted by the Massachusetts Board of Registration of Plumbers and Gas Fitters. • Approved for stationary standby applications in locations Generator Set Ratings served by a reliable utility source. Standby Ratings Natural Gas LPG Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps 4E5.0 120/240 1 60 21/21 87 24/24 100 1W208 3 60 21/26 73 23/28 80 127/220 3 60 21/26 69 23/28 75 120/240 3 60 21/26 63 23/28 69 4D5.0 277/480 3 60 21/26 32 23/28 35 220/380* 3 50 16/20 30 17/22 33 230/400 3 50 16/21 30 18/23 33 240/416* 3 50 16/21 29 18/23 32 * 50 Hz models are factory-connected as 230/400 volts.Field-adjustable to 220/380 or 240/416 volts by an authorized service technician. RATINGS:All three-phase unrls are rated at 0.8 power factor.All single-phase units are rated at 10 power factor Due to manufacturing vanations,the ratings tolerances±5% Standby Ratings.Standby ratings apply to installations served by a reliable utility source.The standby rating Is applicable to varying loads weh an average load factor of 80%for the duration of a power outage.No overload capacity is specified far ft rating Ratings are in accordance with ISO-3046/1,BS 5514,AS 2789,and DIN 6271.GENERAL GUIDELINES FOR DERATING Alftde Derate 13%per 100 In OWL)elevation above 200 in(666 R).Temperature,Derate 3 0%per 10°C(18"l')temperature above 25°C(77°F).AvalabTdy is"act to charge without notice.The generator set mamrfactiner reserves the right to change the design or specifications without notice and without any obfigation or Ilabvey whatsoever Contact your local Kohler generator distnbutor for avallabirdy. 64.228 (24RCL)9/19d Alternator Specifications Specifications Alternator • NEMA MG1,IEEE,and ANSI standards compliance for Manufacturer Kohler temperature rise and motor starting. Type 4-Pole,Rotating Field • Sustained short-circuit current of up to 300%of the rated Exciter type Brushless,Wound-Field current for up to 10 seconds. Leads:quantity,type • Sustained short-circuit current enabling 4E5.0 4,120/240 9 downstream circuit 4D5.0 12,Reconnectable breakers to trip without collapsing the alternator field. Voltage regulator Solid State,Volts/Hz • Self-ventilated and drip-proof construction. Insulation: NEMA MG1 Material Class H • Windings are vacuum-impregnated with epoxy varnish for Temperature rise 130°C,Standby dependability and long life. Bearing:quantity,type 1,Sealed • Superior voltage waveform from a two-thirds itch stator and Coupling Flexible Disc P 9 p Voltage regulation,no-load to full-load .1.0%Maximum skewed rotor. Unbalanced load capability 100%of Rated Standby • Total harmonic distortion(THD)from no load to full load with Current a linear load is less than 5%. One-step load acceptance 100%of Rating Peak motor starting kVA: (35%dip for voltages below) 240 V 4E5.0(4 lead) 37(60 Hz) 480 V,400 V 4D5.0(12 lead) 59(60 Hz) 44(50 Hz) Application Data Engine Exhaust Engine Specifications 60 Hz 50 Hz Exhaust System 60 Hz 50 Hz Manufacturer Kohler Exhaust manifold type Dry Engine:model,type Residential Powertrain Exhaust temperature at rated kW,dry KG2204,2.2 L,4-Cycle exhaust,°C(°F) 633(1171) Natural Aspiration Maximum allowable back pressure, Cylinder arrangement In-line 4 kPa(in.Hg) 7.5(2.2) Displacement,L(cu.in.) 2.2(134.25) Bore and stroke,mm(in.) 91 x 86(3.5 x 3.4) Fuel Compression ratio 10.5:1 Fuel System Piston speed,m/min.(ft./min.) 310(1016) 258(847) Main bearings:quantity,type 5,plain alloy steel Fuel type Natural Gas or LPG Rated rpm 1800 1500 Fuel supply line inlet 1 in.NPT Max.power at rated rpm,kW(HP) Natural gas fuel supply pressure,kPa LPG 30(40) NA (in.H2O) 1.7-2.7(7-11) Natural Gas 27(36) NA LPG vapor withdrawal fuel supply Cylinder head material Cast Iron pressure,kPa(in.H2O) 1.7-2.7(7-11) Piston type and material High Silicon Aluminum Fuel Composition Limits* Nat.Gas LP Gas Crankshaft material Nodular Iron Methane,%by volume 90 min. — Valve(exhaust)material Forged Steel Ethane,%by volume 4.0 max. — Governor type Electronic Propane,%by volume 1.0 max. 85 min. Frequency regulation,no-load to Propene,%by volume 0.1 max. 5.0 max. full-load Isochronous C4 and higher,%by volume 0.3 max. 2.5 max. Frequency regulation,steady state .1.0% Sulfur,ppm mass 25 max. Frequency Fixed Lower heating value, Air cleaner type Dry MJ/m3(BtLkV),min. 33.2(890) 84.2(2260) Engine Electrical * Fuels with other compositions may be acceptable.If your fuel is outside the listed specifications,contact your local distributor for Engine Electrical System further analysis and advice. Ignition system Electronic Lubrication Battery charging alternator: Ground(negative/positive) Negative Lubricating System Volts(DC) 14 Type Full Pressure Ampere rating 90 Oil pan capacity,L(qt.)§ 4.2(44) Starter motor rated voltage(DC) 12 Oil added during oil change(on average), Battery,recommended rating for-18°C(0°F): L(qt.)§ 3.3(3.5) Qty.,cold cranking amps(CCA) One,630 Oil filter:quantity,type§ 1,Cartridge Battery voltage(DC) 12 § Kohler recommends the use of Kohler Genuine oil and fitters. Battery group size 24 G4-228(24RCL)9/19d Application Data Cooling RDC2 Controller Radiator System 60 Hz 50 Hz Ambient temperature,°C(°F) 45(113) Engine jacket water capacity,L(gal.) 2.65(0.7) Radiator system capacity,including voltage 24ov engine,L(gal.) 13.2(3.5) Freq 600Rz Water pump type Centrifugal o Fan diameter,mm(in.) qty.3 @ 406(16) Fan power requirements(powered by ® am AM MW engine battery charging aftemator) 12VDC,18 amps each Operation Requirements ° Air Requirements 60 Hz 50 Hz The RDC2 controller provides integrated control for the Radiator-cooled cooling air, generator set,Kohler@ Model RXT transfer switch, m3/min.(scam)#- 51 (1800) 51 (1800) programmable interface module(PIM),and load management. Combustion air,m3/min.(cfm) 1.4(49) 1.2(42) Air over engine,m3/min.(cfm) 25(900) 25(900) The RDC2 controller's 2-line LCD screen displays status # Air density=1.20 kg/m3(0.075 Ibm/ft3) messages and system settings that are clear and easy to read, Fuel Consumption$ even in direct sunlight or low light. Natural Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz RDC2 Controller Features 100% 8.5 (301) 7.8 (275) • Membrane keypad 75% 55an .6 (199) 5.4 (192) .3 (223) .4 (225) 50% 5 o OFF,AUTO, d RUN push buttons 25% 4.0 (140) 3.3 (116) o Select and arrow buttons for access to system Exercise 2.8 (97) 2.9 (103) configuration and adjustment menus LP Gas,m3/hr.(cfh)at%load 60 Hz 50 Hz • LED indicators for OFF,AUTO,and RUN modes 100% 3.2 (113) 2.7 (96) • LED indicators for utility power and generator set source 75% 2.8 (97) 2.3 (81) availability and ATS position(Model RXT transfer switch 500/. 2.4 (84) 2.0 (72) required) 250/. 1.8 (63) 1.7 (60) • LCD screen Exercise 1.4 (51) 1.4 (48) o Two lines x 16 characters per line # Nominal Fuel Rating: Natural gas,37 MJ/m3(1000 Btu/ft3) o Backlit display with adjustable contrast for excellent LP Vapor,93 MJ/m3(2500 Btu/fl3) visibility in all lighting conditions 8.58 ft. LP vapor conversion factors:-1 Ib. • Scrolling system status display 0.535 m3=1 kg o Generator set status 36.39 ft.3=1 gal. o Voltage and frequency o Engine temperature Sound Enclosure Features o Oil pressure • Sound-attenuating enclosure uses acoustic insulation that o Battery voltage meets UL94 HF1 flammability classification and repels o Engine runtime hours moisture absorption. • Date and time displays • Internally mounted critical silencer. • Smart engine cooldown senses engine temperature • Skid-mounted,aluminum construction with two removable • Digital isochronous governor to maintain steady-state speed access panels. at all loads • Fade-,scratch-,and corrosion-resistant KohlerO cashmere • Digital voltage regulation: ±1.0%RMS no-load to full-load powder-baked finish. • Automatic start with programmed cranking cycle Sound Data • Programmable exerciser can be set to start automatically on any future day and time,and to run every week or every two Model 24RCL 8 point logarithmic average sound levels are weeks 54 dB(A)during weekly engine exercise and 61 dB(A)during • Exercise modes full-speed generator diagnostics and normal operation.For o Unloaded exercise with complete system diagnostics comparison to competitor ratings,the lowest point sound levels o Unloaded full-speed exercise are 52 dB(A)and 60 dB(A) respectively.* o Loaded full-speed exercise(Model RXT ATS required) All sound levels are measured at 7 meters with no load. • Front-access mini USB connector for SrteTech' connection * Lowest of 8 points measured around the generator.Sound levels at other points • Integral Ethernet connector for Kohler®OnCuea Plus around generator may vary depending on installation parameters. g • Built-in 2.5 amp battery charger • Remote two-wire start/stop capability for optional connection of a Model RDT transfer switch See additional controller features on the next page. 64-228(24RCL)9/19d KOHLER CO.,Kohler,Wisconsin 53044 USA Phone 920-457-4441,Fax 920-459-1646 KOHLER, For the nearest sales and service outlet in the US and Canada,phone 1-800-544-2444 KOHLERPoweccom Additional RDC2 Controller Features Available Options, Continued • Diagnostic messages Starting Aids o Displays diagnostic messages for the engine,generator, ❑ Oil Pan Heater,120 V,1 Ph Model RXT transfer switch,programmable interface ❑ Oil Pan Heater,240 V,1 Ph module(PIM),and load management device Recommended for ambient temperatures below 0°C(32°F). o Over 70 diagnostic messages can be displayed • Maintenance reminders Automatic Transfer Switches and Accessories • System settings ❑ Model RDT Automatic Transfer Switch o System voltage,frequency,and phase ❑ Model RXT Automatic Transfer Switch o Voltage adjustment ❑ Model RXT Automatic Transfer Switch with Combined 9 1 Interface/Load Management Board o Measurement system,English or metric ❑ Load Shed tit for RDT or RXT • ATS status(Model RXT ATS required) ❑ Power Relay Modules(use up to 4 relay modules for each o Source availability load management device) o ATS position(normal/utility or emergency/generator) Miscellaneous o Source voltage and frequency ❑ Rated Power Factor Testing • ATS control(Model RXT ATS required) Literature o Source voltage and frequency settings ❑ General Maintenance Literature fit o Engine start time delay ❑ Overhaul literature lit o Transfer time delays ❑ Production Literature Kit o Fixed pickup and dropout settings Warranty o Voltage calibration ❑ Extended 5-Year/2000 Hour Comprehensive Limited Warranty • Programmable interface module(PIM)status displays o Input status(active/inactive) Other Options o Output status(active/inactive) ❑ • Load control menus ❑ o Load status o Test function Generator Set Standard Features • Aluminum sound enclosure with enclosed silencer • Battery rack and cables Dimensions and Weights • Electronic,isochronous governor Overall Size,L x W x H,mm(in.): 1880 x 836 x 1169 ( • Flexible fuel line 74 x 32.9 x 46.0) • Gas fuel system(includes fuel mixer,electronic secondary Shipping Weight,wet,kg(lb.): 572(1260) gas regulator,two gas solenoid valves,and flexible fuel line Weight includes generator set with engine fluids, sound enclosure, between the engine and the skid-mounted fuel system silencer,and packaging. components) • Integral vibration isolation • Line circuit breaker • Oil drain extension • OnCuee Plus Generator Management System H • Operation and installation literature • RDC2 controller with built-in battery charger • Standard five-year or 2000 hour limited warranty Available Options Approvals and Listings NOTE:This drawing is provided for reference only and should not be used for planning installation.Contact your local distributor for more ❑ UL 2200%UL Lasting(60 Hz only) detailed information. ❑ CSA Approval(60 Hz only) DISTRIBUTED BY. Controller Accessories ❑ Lockable Emergency Stop(lockout/tagout) ❑ Programmable Interface Module(PIM) (provides 2 digital inputs and 6 relay outputs) Electrical System ❑ Battery ❑ Battery Heater ®2014,2016,2016,2019 by Kohler Co All rights reserved. G4-226(24RCL)9/194