Loading...
HomeMy WebLinkAbout45274-Z � -gUFFOt,1•�oGy� Town of Southold 10/24/2020 0 P.O.Box 1179 .w 53095 Main Rd �ASouthold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41557 Date: 10/24/2020 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 5194 Great Peconic Bay Blvd, Laurel SCTM#: 473889 Sec/Block/Lot: 128.-2-20 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/9/2020 pursuant to which Building Permit No. 45274 dated 10/2/2020 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"unconditioned three season room addition to an existing two bedroom one family dwelling as applied for per ZBA#7388, dated 7/16/2020. The certificate is issued to Minton TG Family Trt. of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45274 10/21/2020 PLUMBERS CERTIFICATION DATED Au o ' e Signature z' TOWN OF SOUTHOLD ��o�° �ooy BUILDING DEPARTMENT y z TOWN CLERK'S OFFICE "oy . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45274 Date: 10/2/2020 Permission is hereby granted to: Minton Mary Irrevoc Trust 101 Birch Ln New City, NY 10956 To: legalize "as built" additions/alterations to existing single-family dwelling as applied for per ZBA approval. Additional certification maybe required. ` At premises located at: 5194 Great Peconic Bay Blvd SCTM # 473889 Sec/Block/Lot# 128.-2-20 Pursuant to application dated 7/29/2020 and approved by the Building Inspector. To expire on 4/3/2022. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $579.20 CO -ADDITION TO DWELLING $50.00 Total: $629.20 Bu ing Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT T011'N HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: I. Final survey of property with accurate location of all buildings, property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply znd sewerage-disposal (S-9 form). 3. Approval ofelectrical installation from Board of Fire Underwriters. d. Sworn statement tiom plumber certifying that the solder used in system contains less than 2/10 of 1`;'0 lead. 5. Commercial building, industrial building. multiple tesidences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building, 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey ofproperty showing all property lines,streets, building and unusual natural or topographic features. 2. A properly completed application-and consent to inspect signed by the applicant. If Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Feet I. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00, Alterations to dwelling S50.00. Swimming pool$50.00.Accessory building$50.00,Additions ro accessory building$50.00, Businesses$50.00. '. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-S.25 4. Updated C'ertiticrrte of Occr.rpancy- $50.00 5. Temporary Certificate of'Occupancy- Residential $15.00,Commercial $15.00 Date. _ (> New Construction: Old or Pte-existing Building: L '�f - �°' '' —(check one) Location ol'Property: — -_ � -� L- Nf C j�i !/ � /� // L. House No. Strt•et �1�-- Hamlet Owner or 0%%ner,of NOpel ly'- -- �fy��O/lf Clf G — Suffoll.County 'Tai N(ap NO 1000, Section -- — _Block_��— —_Lot - Subdivision - _ _ __----- Filed Map. -- — _ Lot: Petniit No. / - Date of,Permit. Health Dept. Appro\,al: - —/�/ — ---- --- Underwriters Approval: 1'lanning Board Approval: Request lin•: -I cmporary CertiticLae - --- - final Certificate: _ � _ (check one) I'ee Submitted: S Applicant Signature Board of Zoq:lnl bAjuneals Annlication AUTHORIZATION (Where the Applicant is not the Owner) e residiIIg at /O (f / (Print property owner's name) (Mailing Address) /1!•Y !O'er_ do hereby authorize to apply for variance(s)on my behalf from the Southold Zoning Board of'Appcals. (Owner's Signature) _! m 19 � (ter, 11-17 /Iy (Print Owner's Name) r So Town Hall Annex ,rr� ®rte Telephone(631)765-1802 54375 Main Road ia' Fax(631)765-9502 P.O.Box 1179 roger.richert(a-town.southold.ny.us Southold,NY 11971-0959 ®M 011 9 e 9� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Mary Minton Irrevocable Trust Address: 5194 Great Pecornc Bay Blvd. City- Laurel St: New York Zip: 11948 Building Permit#: 45274 Section 128 Block. 2 Lot. 20 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: AS BUILT DBA: License No: SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor X Pool New Renovation 2nd Floor Hot Tub Addition X Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 2 Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures 2 Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 2 Twist Lock Exit Fixtures TVSS Other Equipment: "AS BUILT" "ELECTRICAL SURVEY" "NO VISUAL DEFECTS" Notes* "3-SEASON ROOM" 1-paddle fan Inspector Signature: 6 Date: October 212020 81-Cert Electrical Compliance Form As �z SOUIyo� # # TOWN OF SOUTHOLD BUILDING DEPT. �`y�ou►m � 765-1802 INSPECTION [ ] FOUNDATION 1ST - [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I SULATIOWCAULKING [ ] FRAMING/STRAPPING [ FINAL fe ra [ ] FIREPLACE & CHIMNEY = [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE D �� "w INSPECTOR i oF soulyO{o # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 ANSPECTION 4s [ ] FOUNDATION -1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [. ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ =] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE / d �/ 7� INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS • FOUNDATION(IST) -------------------------------- FOUNDATION(ZND) rA ROUGH FRAMING& 1 PLUMBING INSULATION PER N.Y. NJy STATE ENERGY CODE A. FINAL 9 , ADD :=ISN ;C1XMENTS - Z rn . r a i- TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying9 TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 ' ' Planning Board approval FAX: (631) 765-9502 Survey Southoldtownny.gov PERMIT NO.-` r� Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application 11 Flood Permit Examined l� 202 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved 20U Mail toy!/C-MA L kit, ,LlMAC7L Disapproved a/c P0,00)e/P4n So"0 D� /try /1'71 Phone: 6.,r8 68 o I Expiration ,-20 — Building Inspector Yc APPLICATION FOR'BUILDING PERMIT -, Date t?l29 , 20/10 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE'to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder 464W. Name of owner of premises /-l,IN 7-0 I/ 4RA T.e 415;r— (As ST(As on the tax roll or latest deed), ' If applicant is a corporation, signature of duly authorized officer (Name and title,of corporate officer) Builders License No. MAI Plumbers License No. N fr[Q Electricians License No. Other Trade's License No. �y 1. Location of land on which proposed work will be done: -5-174 GREpr–pzwaw—1 c Ay �LY�., L.4UrLCL House Number Street Hamlet County Tax Map No. 1000 Section l28 ' Block z Lot .910 ,1 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy /�€s�1�,�iV71-Al CA126 OV191V4y b. Intended use and occupancy 9,,65* 4,V Y.4L OBJ& j5AA1/Ly 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work 4456AW2 U/IICoN,D/77GW�',O PO-Zcy (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units aA1,A Number of dwelling units on each floor OAIA If garage, number of cars AZW—.4 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. All—W 7. Dimensions°of Existing structures, if any: Front IS -6 Rear 2 j� Depth 47, 1 Height ' Number of Stories' n4!d �2) Dimensions of same strucurewith alterations or additions: Front /� 3 Rear ;0??. 3 Depth ?;'%;`l,' ' ` Height Number of Stories 7`l�/0 �2) ' tal 8. Dimensions of entire new construction: Front �3. 9 Rear Z F. 'Deptha '` 47. / Height Number of Stories 71-W 13 Z 9. Size of lot: Front- • Rear e95- Depth 97, 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated .p— 4 O 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO X Will excess fill be removed from premises? YES NO 14. Names of Owner of premises Address Phone No. Name of Architect Address Phone No Naive of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO X * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO_X * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OFA) h IOY MZ A kjHACX being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the A6,e5 ,7-- (Contractor,Agent, Corporate Officer,,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his-knowledge and-belief-, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to gore me this day of1TanjjW 4 '20ji2a EY L. DWYERZA62 , Notary Pub is NOTARY PUBLIC,STATE OF NEW YORK Signature of Applicant 0 NO.01 DW6306900 QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30,2-W-,9— FORM NO. 3 1\ � TOWN OF SOUTHOLD BUILDING DEPARTMENT SOUTHOLD, N.Y. NOTICE OF DISAPPROVAL DATE: January 17, 2020 TO: Michael Kimack(Minton) PO Box 1047 Southold, NY 11971 Please take notice that your application dated January 9, 2020: For permit to legalize"as built" additions and alterations to an existing single-family dwelling at: Location of property: 5194 Great Peconic Bay Blvd, Laurel, NY County Tax Map No. 1000 - Section 128 Block 2 Lot 20 Is returned herewith and disapproved on the following grounds: The"as built" construction on this nonconforming 7,028.65 sq. ft. lot in the Residential R-40 District is not permitted pursuant to Article XXIII Section 280-124 which states; lots measuring less than 20,000 square feet in total size require a minimum rear yard setback of 35 feet. The survey notes a rear yArd setback of 1.6 feet. Authorized ignature Note to Applicant: Any change or deviation to the above referenced application may require further review by the Southold Town Building Department. CC: file,Z.B.A. 116ARD MEMBERSSouthold Town Hall Leslie Kanes Weisman,Chairperson (ft%V Oily 53095 Main Road-P.O.Box 1179 Southold,NY 11971-0959- Patricia Acampora Office Location: Eric Dantes G Q Town Annex/First Floor, Robert Lehnert,Jr. 54375 Main Road(at Youngs Avenue) Nicholas Planamento ' ��iYC®U Southold;NY 11971 http://Southoldtownny.gov RECEIVE0 D` ZONING BOARD OF APPEALS & Uai—(9 g:3O AAA J U L 2 9 ' 2020 TOWN OF SOUTHOLD J U L 2 9 2020 Tel.(631)765-1809-Fax(631)765-9064 a, ` I BUMD G DEPT. Sou old Town Clerk FINDINGS,DELIBERATIONS AND DETERMINATION MEETING OF JULY 16, 2020 ZBA FILE: 7388 NAME OF APPLICANT: Minton Irrevocable Trust PROPERTY LOCATION: 5194 GreatTeconie Bay Blvd,Laurel SCTM No. 1000-128-2-20 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps,under SEQRA. SUFFOLK COUNTY-ADMINISTRATIVE CODE: This application was referred asrequired-uncTer flie-Suffoff County Administrative Code'Sections A 14-14 to 23, and the Suffolk County Department of Planning issued its reply dated January 30, 2020 stating that this application is considered a matter for local determination as there appears to be no significant county-wide of inter-community impact. LWRP DETERMINATION: The relief, permit, or interpretation requested in this application is listed under the Minor Actions exempt list and is not subject to review under Chapter 268. PROPERTY FACTS/DESCRIPTION: The subject.property is a 7,028.65 sq.ft. parcel located in an R-40 Zoning District. The property is located 200ft. south of Peconic Bay Boulevard and serviced by a shared dirt road. The property measures 97:76 ft.-along the northerly property-line, parallel to Peconic Bay Boulevard, turning south measuring 85.00 ft. along the easterly property line with access to a 15-foot Right of Way, turning west measuring 97.96 ft. along the southerly property line, then turning north measuring 85.00 ft. along the westerly property line. The property is improved with a two-story framed residence and an attached enclosed porch, all as shown on survey prepared by Kenneth,M. W.oychuk,L.S., dated April 12,2019. BASIS OF APPLICATION. Request for a Variance from Article, XXIII, Sections 280-124 and the Building Inspectors January 17, 2020 Notice of Disapproval based on an application for a permit to legalize %s-built" additions and alterations to an existing single family dwelling; at 1) less than the code required minimum rear yard setback of 35 feet; located at: 5194 Great Peconic Bay Blvd,Laurel,NY. SCTM No. 1000-128-2-20. RELIEF REQUESTED: The applicant requests a variance to legalize an "as-built"porch addition with a rear yard- -- ---------------------------- - q y - - ---- ----- - - --- - - - -- -- ---- setback of 1.6 feet,where a 35-foot setback is re uired b the code. J Page 2,July 16,2020 #7388,Minton SCTM No. 1000-128-2-20 ADDITIONAL INFORMATION:- On May 19, 1964, #669, the prior owner was granted variance relief to subdivide his parcel as well as relief to NYS Town Law 280-a for access to a town road, The applicant's agent submitted copies to the Board of three other prior variances for non-conforming setbacks granted-by the Board of Appeals on Peconic Bay Boulevard: ZBA File#5611.( c,2,2004),ZBA file#6099,.(JAh. 10,2008) and ZBA—File -#7244 May.23,2019) The existing dwelling located on the property was issued a certificate of occupancy in May 1958, # Z-110. In August of 1977, certificate of occupancy # Z7863 was issued for a one family dwelling with Additions and alterations. There was a septic permit issued by the Town of Southold in June of 1997 for a new septic tank. The Board received a letter dated May 2020 (Received May 28, 2020) from a neighbor indicating that she had no objection to the variance relief. FINDINGS OF FACT/REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on July 9,2020 at which time written and oral evidence were presented. Based upon all testimony, documentation,personal inspection of the property and surrounding neighborhood,and other evidence,the Zoning Board finds the following facts to be true and relevant and makes the following findings: 1. Town Law $267-bQ)(b)(IJ Grant of the variance will not,produce an undesirable change in the character of the neighborhood or a detriment to nearby properties.• The neighboring properties are generally the same iron- . conforming size and oddly shaped-configuration as the subject parcel. The subject property'is accessed via a_ private4 rights�v. Tie as built parch is unconditioned space and is in character with-other residences in the surrounding neighborhood. 2. Town Law 4267-bQ)(WQ The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an--area variance. As the as-built addition is attached to the existing residence,there is no other alternative than an area variance. 3. Town Law 8267-b(3)(b)(3): The variance granted herein is mathematically substantial, representing•95.4% relief from the code. However, at least half of the existing house is currently in the conforming rear-yard setback with-the benefit of certificates of occupancy, and the rear yard is screened from view by an existing solid stockade fence. 4. Town Law 8267-b(3)(b)(4). No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. The applicant must comply with Chapter 236 of the Town's Storm Water Management Code and conditions of this board. 5. Town Law $267-0)(b)(5). The difficulty has been self-created. The applicant purchased the parcel after the Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of purchase.- 6. Town Law &267-b, Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of an unconditioned porch while preserving and protecting the character of the neighborhood and the health, safety ety an werfare of the community -- - -- - - --- --- - - - - ------ - --------- - r � PAge 3,Ji 1y,16,2020 _ #7388,Minton SCTM No. 1000-128-2-20 RESOL--UTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Lehnert , seconded by Member Weisman (Chairperson), and duly'carried,to-- ----- - -------- --- ------— i------------- -- -- RANT the variance as applied for, and shown ori,the survey_prepared by-Kenrieth Woychuk, Land Surveyor, dated April 12, 2019. SUBJECT TO THE FOLLOWING CONDITIONS: 1. The existing as-built porch shall remain unconditioned space and shall not be enlarged. That the above conditions be written into the Building Inspector's CertfIcate of"Occupancy, when issued Any deviation from the survey;site plan and/or architectural drawings.cited in this decision will result In delays and/or a possible denial by the Building Department of a building permit, and may require a new application and public hearing before the'ZoningBoard of Appeals. Any deviation from the variance(s)granted herein as shown on the architectural drawings, site plan and/or survey cited above, such as alterations, extensions, or demolitions, are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize,or condone any current or future use, setback or other feature of the subject property that May-violate the Zoning Code, other than such.uses, _setbacks and other features as are expressly addressed in this action. In.the-event that this is an approval subject to conditions, the a approval shall not be deemed effective until such time-that the foregoing conditions are met, and - failure to comply therewith will render this approval null angioid,, The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of noncor{formity. Pursuant to Chapter 280-146(B) of the Code of the Town of Southold any variance granted by the Board of Appeals shall become null and void where a Certificate of Occupancy has not been U procured, and/or a subdivision map has not been filed with the Suffolk County Clerk,within three (3)years from the date such variance was granted. The Board of Appeals may,upon written request prior to the date of expiration, grant an-extension not to exceed three(3) consecutive one (1)year terms. Vote of the Board: Ayes:Members Weisman(Chairperson)Acampora,Dantes,Lehnert, and Planamento(5-0). eslie Kanes Weisman, Chairperson _ APprwed for-filing._7 - _ -/2020 z� BUILDING DEPARTMENT-Electrical Inspectior � x OCA ��` TOWN OF'SOUTHOLD -pwn Hall Annex- 54375 Main Road - PO Box 1179 3�0� Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 ro err. .southoldtownny.gov- seand@southoldtownnyoov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (Ali information Required) Date: Company Name: J\/b t2 _ S Is cam- Name: License No.: email: Address: Phone No.: JOB SITE INFORMATION (All Information Required) Name: In" xv, zrr"b z.- 4 t� Address: 5rj3 Ivr/ Cross Street: Phone No.: g-qS 2.2.2- -69.6 (.o Bldg.Permit#: 4 5 2'7 email: '� ,� as{•��.✓� Tax Map District: 1000 Secti-on, i o2 $ Block: Lot: c (J BRIEF DESCRIPTION OF WORK(Please Print Clearly) Circle All That Apply: Is job ready for inspection?: CYS / O Rough In Final Do you need a Temp Certificate?: YES /0'10, Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect-Flood Reconnect-Service Reconnected - Underground -Overhead Underground Laterals 1 2 H Frame Pole Work done on Service? Y N "Additional Information:. _PAYMENT DUE WITH APPLICATION Request for Inspection FormAs ®���' �� v �. �� T0: Town of Southold Zoning Board of Appeals DATE: July 5,2020 RE: Public Hearing July 9,2020 Minton Irrevocable Trust#7388 Request for Variance Section 280-124 5194 Great Peconic Bay Boulevard, Laurel, NY 11948 SCIM 1000-128-2-20 The Minton family is requesting a variance on an addition added to the northwest portion of their property. We have been next door neighbors to the Mintons since 1989,and this addition was there for years prior to 1989. We support the approval of the variance because there is no reason to oppose it based upon the length of time that the structure has been there,and it does not encroach on any surrounding homes. We, therefore,hope that the Board will approve this variance request. Thank you for your consideration. Carolyn and Ronald Coons 5206 Great Peconic Bay Boulevard Laurel, NY 11948 516 320-0142 SULL \ L2J. lab --#, ? Ll 6 L'A 0 LA.� s Iit I •J t1 '• Bldg Dept copy from ZBA Final reviewed documents ZBA File# 7396- 0 F o F- U a � RECEIVED ED AR W �' C:Liii .. F. JAN 2020 Zoning Board Of Appeals * I Q a zy U x N � 041861 O�� U o _ s�TFOF NNP4Q a PORCH m I UNCONDITIONED 3 SEASON I m O � • W � Z O PART'I AL U" 1= I RST FLOOR 'LAIN a � SCALE: )4"'-1'-0" AS BUILT ADDITION In LEGEND A � I EXISTING WALL NOR 1 �"� ELF-VAT I ON Dra�By. """`' Date: AS BUILT ADDITION y 12"2"`' DrawingNo.: - �o OF SHEETS Jim ji Bldg Dept copy from ZBA Final reviewed d uments ZBA File# '73 o Date-.-7,/ 1lo I�� H u d U a >' U A o0 0 Q U U x C, - I • aU J1 IL � p � U _ a d- a AS BUILT ADDITION AS BUILT ADDITION �\Sc RED ARc'y/ ST L E�/�.T I ON lel ST E L�\/AT I ON Drawnsy: SCALE: %4"-1'—O" ( SCALE, 4"-1'-0" Rrtrt * Date: 1a.Azw DmwingNo.: s�,yT 04186A �•� FOF NEW a OF SIiEETS 6Q APPRO ED AS NOTED DATE:- FEE / BY: NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: ����. ����� 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE INSPECTION REQUIRED 2. ROUGH-- FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF Additional NEW YORK STATE & TOWN CODES Certification AS R=SOUTHOLD D CONDITIONS OF May Be Required. TOWN ZBA RD S0U7a7TMV`R0EES ®`rel v c+ nen OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY c � .ilk LLE 2 � ! A-2 SEP 3 0 2020 E ,nG DEI ° 15'-6° (2) 2 X 8 HDR 3'-4° X 4'-4°ANDERSEN �s 8p D.H WINDOW O9 EXISTING 2 x 8 ROOF o " RAFTERS ABOVE ® 16' O.0 z W/1/2° GYP BD PAINTED. 3� W/ R11 BATT INSULATION Ui EXISTING THREE SEASONS v o ROOM (UNCONDTIONED) TO BE a EXISTING KITCHEN 00 co EXISTING FIBERGLASS MAINTAINED-224 S F. z I PITCH Lu x r 1 i2 ASPHALT FLAT ROOF EXISTING 2 X 6 ACQ FLOOR w `IJ -1/2 MEMBRANE JOIST SLEEPERS W/ R19 0 1'-9 1/2° BATT INSULATION W/5/8° Q TONGE AND GROOVE PLYWOOD AND VINYL TILE x OVER CONCRETE SLAB C° CSI CLOSET OQ ��� _ +I EXISTING PAINTED SIDING W/ ZD PAINTED PINE TRIM 3'-4' X 4'-4'ANDERSEN °9 DH. WINDOW . _ I L==Ji (2) 2 X 8 HDR 13'-5° EXISTING 2 X 4 EXTERIOR STUD WALL 16° O.0 W/ R11 BATT INSULATION, ° 4 EXISTING LIVING ROOM CDX EXTERIOR PLYWOOD, TAR PAPER I I I TRENCH CONCRETE FOOTING AND SIDING ALUM, TERMIITE SHELD AND ACO PLATES I AND SLAB +3' BELOW GRADE 2 L > 1 PLAN ® 3 SEASONS ROOM 2 ELEVATION EAST SIDE �J ` � •-�� ' A-1 SCALE: 1/4'=1'-0° A-1 SCALE: 1/4°=1'-0° �'� 0 DATE, ISSUE. l 092820 ISSUED TO TOWN FOR REVIEW AND APPROVAL MICHAEL ZAMPINI PROJECT PROJECT DATE 2 FANM RESM84112 202011D 091520 3. 6794 PEC� UREIC BAY BLVD LAUREL-, NY T1948 SCALE DRAWN BY AS NOTED w A M P I N I DRAWM TITLE ZR.-llT..TllRr-, h C. FLOOR PLAN AND ELEVATIONS A— ■ 2 LOR1NG ROA—LEVi OWN,N n 11756°516.579.7352 REGISTERED ARCHITECT it y 1 EXISTING FIBERGLASS ASPHALT FLAT ROOF MEMBRANE EXISTING PAINTED SIDING W/ PAINTED'PINE TRIM +I 0 06P TRENCH CONCRETE FOOTING L - - - - - - - - - - - - - - - - J AND SLAB :3' BELOW L - - - - - L I GRADE - - - - - - - - - - - I - - - I D A,90 - - - - - - - - - -� ELEVATION NORTH SIDE ELEVATION _ A-1 WEST SIDE SCALE: 1/4"=1'-0" A-1 SCALE: 1/4"=1'-0" OF DATE- ISSUE. ■ MICHAEL ZAMPINI PROJECT ■n-�y, ��p�a�. PROJECT DATE ■ PAN=RMDEIYM 2020.110 091520 092820 ISSUED TO TOWN FOR REVIEW AND APPROVAL 2 , 3 _ ■ 8194 PECONIC BAY BLVD. SCALE DRAWN BY ■ LAUfiEL, NY M" SCALE NOT® AQ AMPINI D� e A ■ Z..,-,,T,.TU. ,CF,C. ^M� C 2 LCR.....—LevrtioWN,N.Y.11756"516.579.735Z REOI9TERE�ARCHITECT11