Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
44846-Z
S,a6F04cOG Town of Southold 10/23/2020 g P.O.Box 1179 Ar 53095 Main Rd o4 �ap�� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41539 Date: 10/20/2020 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 75 Wild Cherry Way, Greenport SCTM#: 473889 Sec/Block/Lot: 52.-3-27 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/1/2020 pursuant to which Building Permit No. 44846 dated 6/9/2020 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels as applied for. The certificate is issued to Zuniga,Roger&Debra of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 44846 9/15/2020 PLUMBERS CERTIFICATION DATED Authorized Signature 'fFQ(fF TOWN OF SOUTHOLD �o�gU �y BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE SOUTHOLD, NY o � BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 44846 Date: 6/9/2020 Permission is hereby granted to: Fed National Mtge Assoc 5600 Granite Pkwy Plano, TX 75024 To: install roof-mounted solar panels as applied for. At premises located at: 75 Wild Cherry Way, Greenport SCTM # 473889 Sec/Block/Lot# 52.-3-27 Pursuant to application dated 4/1/2020 and approved by the Building Inspector. To expire on 12/9/2021. Fees: SOLAR PANELS $50.00 CO-ALTERATION TO DWELLING $50.00 adi"ng Total: $100.00 Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1502 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00, Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial $15.00 1 Date. (�jl�j Lam New Construction: Old or Pre-existing Building: (check one) Location of Property: `L\ House No. Street i Hamlet Owner or Owners of Property: 75 Wild Cherry Way, Southold, NY 11971 Suffolk County Tax Map No 1000, Section 53 Block 3 Lot 27 Subdivision '' (,( Filed Map. Lot: Permit No. f ` Date of Permit. Applicant: Scott MaSI(Ill ` Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ ignature Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 '' Southold,NY 11971-0959 �° z-; �� sean.deviin(D-town.southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Roger Zuniga Address: 75 Wild Cherry Way city Greenport st: NY zip: 11944 Building Permit#: 44846 Section: 52 Block. 3 Lot 27 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: SUNation Solar License No: 33412ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceding Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency FixturesTime Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment 9.62kW Roof Mounted PV Solar Energy System w/26 Solaria PowerXT-370-R-PD Modules and 26 Enphase IQ7 Plus Microinverters, 60A AC Disconnect, Enphase IQ Combiner3 Notes: Solar Inspector Signature: Date: September 15, 2020 S.Devlin-Cert Electrical Compliance Form As Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) I, Debra Zuniga residing at 75 Wild Cherry Way (Print property owner's name) (Mailing Address) Southold, NY 11971 do hereby authorize Scott Maskin, (Agent) Sunation Solar Systems, Inc. to apply on my behalf to the Southold Building Department. c. (Owner's Signatur (Date) VICTORIA M. WALKER Debra Zuniga NOTARY PUBLIC-STATE OF NEW YORK No. O1 WA6319756 (Print Owner's Name) ®ualifl®d In Suf$olk County My Commisslon Ezplres Vebruory 23, 3 JjA60_ SOUT7s- W, /ci CAely-?TOWN OF SOU THO UILDING DEPT Vvq 765-1802 INSPECTION g [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O�C- / REMARKS: vv cj� y DATE INSPECTOR Graham Associates 1981 Union Blvd. Bay Shore,N.Y. 11706 Building Consultants &Expeditors (631)665-9619 Fax(631)969-0115 August 31, 2020 Town of Southol E23 U Building Department )°` er OCT - 9 2020 Re: Peiintit# 44846 Zuniga Residence 75 Wild Cherry Way, Southold Installation Inspection Date: 8-28-2020 To Whom It May Concern, The roof mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the approved plans and is certified by Graham Associates to be in compliance with the minimum requirements of the Town, the 2015-International Residential Code and the 2017-New York State Uniform Code Supplement and the Provisions of ASCE 7-10. If you have any further questions, do not hesitate to call. Sincerely,, L/ C, Michae-1-IM nn, RA C 11 ", �? FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(IST) ----------------------------------- Lc� FOUNDATION(2ND) � � � g ROUGH FRAMING& w � PLUMBING INSULATION PER N.Y. STATE ENEkGY CODE ' F i i a FINAL T z ADD ia 0"NA.L COMMENTS CLQ O X H ►N TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applymg9 TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX:(631)765-9502 �u — Survey SoutholdTown.NorthFork.net PERMIT NO. ` y Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application ,Flood Permit Examined 20 Single&Separate Storm-Water Assessment Form Co act: Approved 20 Mail to:SUNatlon Solar Systems,Inc Disapproved a/c 171 Remington Boulevard,Ronkonkoma NY 11779 Phone (631)750-9454 Exp ration 20 - Building Inspector APR - 1 2020 APPLICATION FOR BUILDING PERMIT Date ,20':�d INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension df the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and re lations,and to admit authorized inspectors on premises and in building for necessary inspections. ure of app i t or name,if a coiporat ) SUNatlon Solar Systems,Inc 171 Remington Boulevard,Ronkonkoma NY 11779 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder SUNatlon Solar Systems,Inc-Contractor Name of owner of premises Debra Zuniga (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer Scott Maskm-President (Name and title of corporate officer) Builders License No.44104-H Plumbers License No. N/A Electricians License No.33412-ME Other Trade's License No. 1. Location of land on which proposed work will be done: 75 Wild Cherry Way Southold House Number - Street Hamlet County Tax Map No.,1000 Section 52 Block 3 Lot 27 M ":1.4 )Pi)' Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Residence b. Intended use and occupancy Residence with addition of Solar Panels 3. Nature of work(check which applicable):New Building Add ition__I] Alteration� Repair Removal Demolition Other WorkS.lmlaraia (Description) 4. Estimated Cos��L-Iq Fee $200 00 (To be paid on tiling this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any: Front Rear Depth n Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law,ordinance or regulation?YES_NO X 13.Will lot be re-graded?YES_NO X Will excess fill be removed from premises?YES_NO X 14.Names of Owner of premises Debra Zunlga Address 75 Wild cherry Way,Southold,NY 1197+Phone No. 646-651-2530 Name of Arch itect1 iCL-OQ . t ���Y�Address ` e� hone No 1 Name of Contractor SUNation Solar Systems,Inc Address 171 Remington Boule—d RoakoakomaN„Phone No. 631-750-9454 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO X *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland?*YES NO X *IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO X *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Scott Maskln-President-SUNatlon Solar Systems,Inc being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me ti day of ,L�20 Notary'Public r ant VICTORIA M. WALKER NQTARY PUBLIC-STATE OF NEW YORK No. O1 WA6319756 ®uollfl®d In Suffolk County Nly Commisst6n Expires February 23, 3 OF$D(Jj�o� , Town Ball Annex , J�f Te�lerphone(631)r7g65p1g802 54375 Main Road rtd uth Itl P.O.Box 1179 y Q roger riche I01ARI 160 o nv us Southold,NY 11971.0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Nadine Valoy Date: 8/31/2020 Company Name: SUNation Solar Systems,Inc. Name: Scott Maskin License No.: 33412-ME Address: 171 Remington Blvd,Ronkonkoma,NY 11779 hone No.: 631-7503454 JOBSITE INFORMATION: (*Indicates required infotmatibn) Name: Debra Zuni a *Address: 75 Wild rhernr Way, Southold, NY 119 1 *Cross Street: *Phone No.: —.646-651-2530 Permit No.: L ' Tax-Map District: 1000 Section: 59 Block: 3 Lot *BRIEF DESCRIPTION OF WORK(Please Print Clearly) '9620KW Roof Mounted Solar Photovoltaic System Including: 26 Solaria Powerxt-3jU-H-FjD w/26 EnDhase IQ7 PLUS Microlnverters. 60 Amp fused service Isconnect: (Please Circle All That Apply) *Is job ready for Inspectibn: Q/NO Rough in Final *Do you need a Temp Certificate: Up'/NO Temp Information(If needed) *Service Size: 1 Phase 3Phase , 100 150 200 300 350 400 Other 'New-Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION B24Request for Inspection Form IS �ew�afS �� n � �r .�'/� 'L`'� � h-e- dJs coM e2.Y' l i CERnFFICATtOIS HEREON SIGNIFY THAT THIS PLAT OF PRDPERIY 6 A TRUE AND CORREL'T R04RI:_WUATION OF A RE'QW MWEY MADE UNDER IAM ME GTp�j IN/=;M1NCE WfNM THE DMW CODE OF PRAC= FOR LAND SURVEYORS BY THE NEw YORK STATE A550CLAT*N OF PROFESSIONAL LAND SURVEIDRSL SAKI CE21MTIONS SHALL RUN ONLY TO nT PE WN mm THE SURVEY WAS PREPARED AND ON THEM BEHALF TO THE TM.E COMPANY,GOVERNMEHTAL AGENCY AND LENDING MUMON WM HOOK THIS CMTMTION S ONLY FOR THE LANDS UESCRUM HEIRETR ILS HOf A CEiT61CA7WN OP 711ILE. MHM OR FREEDOM FROM ENCU6MRWCE3.CERTIFICATIONS ARE NOT NOT TRANSFERABLE TO ADDI110NAL OR SUBSEOUENf OWNERS. f LAND NOW OR FOMERLY OF DALY S 14025'00" E 140.00' FB, I 1•� CHAIN LINK FENC8 037 — — T � Fli MON 0.48 02B �• FB 1.713 12V 23'W C � INS x M x g Fi 00 1 1 00 FE ooNcaRs18 4T f WaROUND POOL x D O a FE OA7s 1 x w � O a LOT 3 � 5 0 1 (A7E1 z 20.VLOT ODNG 6 20.8 37.1' 1sr :. 1F STORY M MASONRY PE — — ---1 DWELLING 1 o srs W a 21.4' „s0L h 21.2' 0 0 Z-1 - _ =-e - o LOT tn 1 F 1 4 A z mom — — — — — FND. N 1425'00" W 140.00' W1LD CI-MRRY WA-Y- 0 Tm OrF3cTS-OZ Dwr—Mi m 5_H_TYFRoM Tr cf rr'SIERIS TO Tiic-PR6?E'Rr TY LNES ARE fOR A"SPECIFIC PURNXSE-ANO USF,-AMID'THEREFlDf E AlRE N0T Drt}?t>m 10!!E Vi D llS"A`GUDE DR THE ES�RON '-- OF FENCES, WALLS, P00M PAWS, BLRLDDNGS,ADUnO S TO BUWINGS OR ANY OTHER OPROVEM NT&SUBSURFACE AND EMYIORNYENTAL CONDR M NOT 940M PROPERLY CORNER MARIMM WERE NOF SET AS A PARE OF THS SURVEY.EASEMENTS AND OR RXHLSOF--WAY OF RECORD. IF ANY; NOT SHOWN. PJM LAND SURVEYING, PLLC UNAUTHORIZED ALM?AnON OR 132 CLYDE STREET/SUITE 16 ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF WEST SAYVILLE,NY 11796 NEW YORK STATE EDUCATION LAW. PHONE 631-563-0400 FAX 631-563-5808 PJMSUR AOL.COM LOT:S REVISIONS MAP OF:SHORECREST AT ARSHAMOMOGUE FILED:APRM 6 1971 NO:5584 COUNTY:SUFFOLK SITUATE:SOUTHOLD TOWN OF SOUTHOLD COPIES OF THIS SURVEY MAP NOT TITLE NO.:WET-041871MWS BEARING THE LAND SURVEYOR'S CERTIFIED TO: EMBOSSED SEAL AND SIGNATURE ROGER ZUNIGA&DEBRA ZUNIGA FALL. NOT BE CONSIDERED A TRUE FREEDOM MORTGAGE CORPORATION,ISAOA/ATDdA A D VALID COPY INTRACOASTAL ABSTRACT CO.,INC. PROJECT NO.:2019-500 WESTCOR LAND TITLE INSURANCE COMPANY JDATM-12/12/12 I DRAWN:CM CEIECKED BY:PM SCALE: 1"–30' DLSTRICT: 1000 SECTION.52 BLOCK 03 LOT(S):27 i i ��°suFFq,��� ST�O�ll�.��l WA\TIE]k Scott A. Mussell SUPERVISOR AM[A\N A(G IEMTENT SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 2w 'own of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOLES THIS PROJECT T INVOILVIE ANY OF THE FOLLOWING: Yes No (CHECK ALL THAT APPLY) ❑ A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑[v�C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑[�D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑DE. Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. ❑❑/F. Installation of-new or resurfaced impervious surfaces of 1,000 Square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. ;k If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT (Property Owner,Design Professional,Agent,Contractor,Other) S.C.T.M. 1000 Date- District NAME Scott Maskin 5a 3 a� o Section Block Lot °" - 4 **** FOR BUILDING DEPARTMENT USE ONLY**** Contact Information. 631-750 CrelcphoK Yumbrrl Reviewed By. - - - - - - - - - - - - - - - - - — U- - - - - - - - - - - - - - - Date: — Property Address/ Location of Construction Work: — — — — — — — — — — — — — — — — 75 Wild Cherry Way Approved for processing Building Permit. Stormwater Management Control Plan Not Required. Southold, NY 11971 Stormwater Management Control Plan is Required. E] (Forward to Engineering Department for Review.) FORM # SMCP-TOS MAY 2014 Graham Associates 1981 Union Blvd. Bay Shore,N.Y. 11706 Building Consultants & Expeditors (631)665-9619 Fax(631)969-0115 March 17, 2020 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: Zuniga Residence 75 Wild Cherry Way Southold, NY 11971 9.62 KW Rooftop Solar Photovoltaic System To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 130 mph wind load without overstress, in accordance with the following: 2015 International Residential Code (2015 IRC, 2ND PRINTING) + 2017 New York State Uniform Code Supplement (2017 NYSUCS); Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2014 National Electric Code NFPA 70/2014 National Electric Code including ASCE?-10 If you have any further ons, do not hesitate to call. ,VkE� Sincerely, �C, Michael K Du � a ®P NSO e 1 T Bunch, Connie From: Nadine Valoy <nvaloy@sunation.com> Sent: Monday,August 31, 2020 1:16 PM To: Bunch, Connie s' Subject: RE: Ready for Inspections-Zuniga, Debra, 75 Wild Cherry Way, Southold Attachments: Zuniga_Southold Elec App.pdf Hello, The following job is ready for inspection. I attached the electrical application. Please let me know if you need anything else. Thank you, Nadine Valoy Nadine Valoy Processing Coordinator,EXT.304 SUNation Solar Systems, Inc. 171 Remington Blvd Ronkonkoma, New York 11779 Phone: (631)750-9454 Fax: (631)750-9455 Like Us on Facebook for all your SUNation News and Events! Follow us on Twitter Follow us on Instagram V SUNation = H +� '` �criat,rtfsitacric�kt� October 5, 2020 Solar Permit Closeout Permit # 44846 Debra Zuniga 75 Wild Cherry Way Southold, NY 11971 info@,su,nations.ola,rsystems.CO631GM94ol,�a NYSIF199 CHURCH STREET,NEW YORK,N.Y.10007-1100 New York State Insurance Fund I nysif.com CERTIFICATE OF WORKERS' COMPENSATION INSURANCE A A A A A 753118816 0 0 SUNATION ROOFING SERVICES INC , 171 REMINGTON BOULEVARD r RONKONKOMA NY 11779 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z 2160 670-2 673648 01/01/2020 TO 01/01/2021 12/30/2019 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW,AND,WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK,TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY, INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE, VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/ CERTVAL.ASP. THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR, INSURANCE FUND UNDERWRITING VALIDATION NUMBER- 466215364 0001ll 1000000000 Hill HII] 111111IIIII111111III III�IIIIIIII� Form WC-CERT-NOPRINT Version 3(08/29/2019)[WC Policy-21606702] U-26 3 Sr ........—..-r......,,r— I Show Receipt Detail Page 1 of 2 f I RECEIPT Suffolk County Government SUFFOLK COUNTY LABOR, LICENSING&CONSUMER AFFAIRS P.0 BOX 6100 HAUPPAUGE, NY 11788 James M.Andrews Application:ME-33412 Application Type:ConsumerAffairs/Licenses/Master Electrician/NA Address: Owner Name:SUNATION SOLAR SYSTEMS INC Owner Address:171 REMINGTON BLVD RONKONKOMA,NY 11779 Application Name: Receipt No. 160594 Payment Method Ref Number Amount Paid Payment Date Cashier ID Received Comments Check 27486 $400.00 06/04/2019 CLEMON RENEWAL Owner info: SUNATION SOLAR SYSTEMS INC 171 REMINGTON BLVD RONKONKOMA, NY 11779 Work Description: y; Suffolk County Dept.of Labor,Licensing&Consumer Affairs f MASTER ELECTRICAL LICENSE i Name SCOTT A MASKIN R—Z' Business Name` This certifies that the SLINATION SOLAR SYSTEMS INC bearer is duly licensed by the County of suffolk License Number:ME-33412 Fra-Z NardzU,i. Issued: 06/24/2003 I Commissioner Expires: 06/0112021 https://avprod.suffolkcountyny.gov/portlets/fee/receiptV iew.do?mode=view&autoPrint=fals... 6/4/2019 t SUFFOLK COUNTY DEPT OF LABOR, LICENSING&CONSUMER AFFAIRS HOMEIMPROVEMENT CONTRACTOR L'ICEUSE i"tlf RAW SCOTT MASKIN This certifies that the BUSNES3NAME bearer Is duly SUNATION SOLAR SYSTEMS INC licensed by the o�.k County of Suffolk 44104-H 03/06/2008 `°"""`°""" GWRATONVATV 03/01/2020 011VIED jll� CoVpLy WITH ALL CODES OWN CODES S OF NeW yoRK STATE &,T' FkEQUIRED A AS �THFY BU!LDINIG TO HOLD T PLANNINGBOARD 4 PM FOR Tl-',L- 8AM OujHOLD T 17CLIL-OVVING INSPECT10NIS: TH, ANN" OUIHOLDT PL ES F01 INDATION - TWO REQUIRED FOR POURED CONCRETE I ji .,t. D E 07 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTSUCTIONMUST EE COMPLETE FOR (10. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR OCCURA-MY 'OR DESIGN OR CONSTRUCTION ERRORS. ' USE IS UNLN-VVFUL WIT H OUT CERTIFICATE OF OCCUPANCY UTILITY METER - Cy PLAN KEY SERVICE DISCONNECT - 9D ��co �L K. PV-I SITE PLAN MAIN SERVICE PANEL - �Yy WIFI ROUTER - A-1 PARTIAL LAYOUT RIDGE >f'IW40TOvOLTAIC -1.\ VENT PIPE - IQ COMBINER - A-2 ROOF ACCESS PLAN PANEL PHOTOVOLTAIC - A-3ENPHASE CIRCUIT DIAGRAM AG DISCONNECT - - _ SUPPLY SIDE CONNECTION - '9�. 029 11 E-I ELECTRICAL ONE LINE SENSE MONITOR - DIAGRAM Ev CHARGER - L-1 LABELING SCHEMATIC RAIL TESLA POWERWALL- G-1 PHOTOS RAFTER TESLA GATEWAY - 2"x 6" l 16'O.G. EXTERIOR LOCATION -SMI IST FLOOR LOCATION - o.n Nation ASEMENT LOCATION - 1. ACTUAL SPAN 50FFIi o B IT ————————— GARAGE LOCATION - we�ATREMINSOLAR SSYSTEMS ON BLVD EXTERIOR WALL ❑ ❑ ❑ ❑ RONKONKOMA NY 11119 ROOF SECTION(TYR)-ROOF"I" _ al)N HOPULE+ SCALE vv[VV7 INSSTALLE N.T.S NTAI I ER 43E6 MULTIPLE ROOF Q STRUCTURE NUMBER ROOF "I" ] CUSTOMER INFO RAFTER/SPACING.2'X 6"1 I6"O.C. F, ZUNIGA RESIDENCE ACTUAL SPAN 18'1" S' RIDGE 21-4.5'• 15 WILD CHERRY WAY SHEATHING PLYWOOD \ SOUTHOLD 11911 COLLAR TIES N/A PHOTOVOLTAIC JOB NUMBER TYPE/LAYERS ARCH ASPHALT/I MODULE 191136 <IS)Pv MODW2S (pI ROOF"2" ^�' eXTI DATE O _ RAFTER/SPAGNG:2"X 6"1 Ib"OC RAFTER ACTUAL SPANS I4'-5" 2"X 6"l 16"O.G. 1 �" 0 JOB NOTES EXISTING INTERIOR RAIL SHEATHING-PLYWOOD DEARING WALL I N/A COLLAR TIES'N/A TYPE I LAYERS ARCH.ASPHALT/I ACTUAL SPAN 20'-5 5 SOFFIT i FULL HOUSE ROOF PLAN EXTERIOR WALL SCALE: N.T.S. ROOF SECTION(TYP)-ROOF"2" SCALE N.T S FASTENER REQUIREMENTS BUILDING REVIEW NOTE NOTES TOTAL ARRAY AREA = 515 SF TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE I. THIS PV SYSTEM HAS BEEN DESIGNED TO MEET ALL WIND LOAD ASCE 10 (SEE CALCULATIONS, THIS SHEET)41 5 ENCLOSED DOCUMENT FOR MINIMUM ACCEPTABLE CURRENT AND APPLICABLE FIRE PREVENTION PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SETBACK PATHWAYS PER THE 2015 IRC SECTION PSF MAX. SPECIFIED IN THE BUILDING AND/OR RESIDENTIAL R324 AND 2011 NYS CODE SUPPLEMENT PROPER TOTAL UPLIFT =41 5 PSF X 515 SF =21,38518 LBS CODE OF THE STATE OF NEW YORK. THI5 REVIEW GROUND CLEARANCE,ROOF ACCESS POINTS, ADDITIONAL MATERIALS DOES NOT GUARANTEE COMPLIANCE WITH THAT CODE. ACCESS PATHWAYS, AND VENTILATION SHALL BE I N/A MODEL SOLARIA POWERXT-310R-PD FASTENER THAT RESPONSIBILITY 15 GUARANTEED UNDER THE PROVIDED WHERE NECESSARY. AN IN DEPTH 310 WATT EA. SEAL AND SIGNATURE OF THE NEW YORK STATE DESCRIPTION OF EACH APPLICABLE CODE 63.8"L X 43.9"W X 1.51D, 19.45 FT' LAG SCREW SPEC 203.2, 8/04 (FLAT WASHERS REQUIRED TO BE USED WITH LAG LICENSED DESIGN PROFESSIONAL OF RECORD. THAT REFERENCE AND EXCEPTION FOR ANY CODES 15 46#/MODULE (2.4#/SF)12/2019 BOLTS) SEAL AND SIGNATURE HAS BEEN INTERPRETED AS AN DEPICTED ON THE A-2 PLATE OF THIS DRAWING MODULE (26)POWERXT-310R-PD LAG BOLT WITHDRAWAL VALUE; 5/1(o" DIA., 266 LB/IN X 2-INCH THREAD DEPTH = ATTESTATION THAT, TO THE BEST OF THE UCENSEE'S PACKAGE MICRO INVERTER (26)ENPHASE 101PLUS-12-2-US 5321-13 GAP. EACH BELIEF AND INFORMATION THE WORK IN DOCUMENT IS 2. ROOF SHALL HAVE NO MORE THAN A SINGLE BRANCH MI 1,2 0 X 13) MINIMUM NUMBER OF LAG BOLTS REQUIRED =21,385 18 UBS /532 LBS/LAG BOLT . ACCURATE LAYER OF ROOF COVERING IN ADDITION TO THE BRANCHSOLAR EQUIPMENT •2 2(1 X 13) 41 . CONFORMS WITH GOVERNING CODES APPLICABLE DRAWN BY . RACKING SNAP'NRACK-ULTRA RAIL TOTAL RAIL FEET = 238'-0" RAIL FT /41 BOLTS= 5'-9" AT THE TIME OF THE SUBMISSION ANTHONY BOUCHARD PACKAGE STANDARD MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS "X" USE 4'-0" MAX • CONFORMS WITH REASONABLE STANDARDS OF 3 INSTALLATION OF SOLAR EQUIPMENT SHALL BE SYSTEM RATING(DC) 9.62 KW PRACTICE AND WITH VIEW TO THE SAFEGUARDING FLUSH-MOUNTED, PARALLEL TO AND NO MORE REVISION EST.PRODUCTION(AG 10,460 KWH/YR THAN 6-INCHES ABOVE THE SURFACE OF THE DATE DESIGNER NOTE EST PRODUCTION SOURCE AURORA OF LIFE, HEALTH, PROPERTY AND PUBLIC ROOF WELFARE IS THE RESPONSIBILITY OF THE LIC .ENSEE 3.162e DOUCHARD FINAL 4 WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF. XX)oxx N/A N/A STRUCTURAL STATEMENT 5. ANY PLUMBING VENTS ARE NOT TO BE GUT OR XXXXXX WA WA COVERED FOR SOLAR EQUIPMENT INSTALLATION. CLIMATIC f GEOGRAPHIC DESIGN CRITERIA - TABLE 8301.20) THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT ANY RELOCATION OR MODIFICATION OF THE xxXx N/A N/A THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC VENT REQUIRES A PLUMBING PERMIT AND SCALE WIND DESIGN SUBJECT TO DAMAGE MODULE SYSTEM INCLUDING UPLIFT Q SHEAR THE INSPECTION. EXISTING RAFTER SIZES 4 DIMENSIONS CONFORM TO THIS Pv SYSTEM HAS BEEN DESIGNED TO MEET THE N.T.S. SPECIAL WIND WIND SEISMIC FROST WINTER ICE AIR MEAN !RC-2015 TABLE R802.50)- RAFTER SPANS GROUND SPEED TOPOGRAPHIC EXPOSURE BORNE CLIMATE BARRIER FLOOD MINIMUM DESIGN STANDARDS FOR BUILDING AND TITLE SITE PLAN SNOW LOAD (MPH) EFFECTS WIND CATEGORY DEBRIS DESIGN ZONE WEATHERING LINE TERMITE DESIGN FREEZING ANNUAL REGION CATEGORY DEPTH TEMP UNDERLAYMENT HAZARD INDEX TEMP OTHER STRUCTURES OF THE ASCE 1-10, IRC 2015 ZONE REQUIRED MOUNTING BRACKETS AND HARDWARE MEET OR MOD SEE EXCEED NEW YORK STATE CODE REQUIREMENTS FOR AND NEW YORK STATE UCS 2011. 20 PSF 130 B YES G 2 G 4A SEVERE 3-0` TO ISDEG NA PLANS 599 51 THE DESIGN CRITERIA OF THE TOWN. P V HEAVY EXAMINER -LQ a3AOadde v 1noAV1 lvllavd 37111 V/N VM xxxxxx VM VM xxxxxx WIN VM XXxx 1"M aaVH' IOa 9991f BION a3N�163O 31VG NOI6In3a Na ons, WnTVOOV W „4-,S I ✓� Lo NmVaO �A V3aV dOOa A x (xllaVl7 U V/N I aOd N(nOHS Orth.L-lNO) 6lVIa31VW-VNOIIIOCV (J.VaaV d0 MON H7V3 - -- -- ,4-,I SSOa7V,1IVN 1V71d11) W314.LS�1�Va,N,dVNS moa N33m139 nz/1►-,1z '�NI7VdS j < 44 ?J311n�e%s-,es ,t-,91 3vCI I?1 AAA o3amv3a < 44 SJ3N319VdN33IMAG VNIOVdS,84,1V16V0o I S310N GOr 0Z'ZZ-1 3ab'HS Wb' BINDAAl 9�L 16l a39WnN G0r IL6ll alOHlnOS ,LVM LNN3H0 MIM 4L 3ON33183N VVINnZ (d.11)3nnaow s3-in40W (41) OMNI 63WOlSnO 71VljONOlOH4 H011d ZIx rl'111 obl '3n?1l ,Lbt a3awnN o 0 91 a a3111y1sNl ,9 x„L a a d00N H1nOS HOd (Z) V aa39A N 6LLIi ,LN VWONNO>NON CA-19 NOl%NIW3N ILI SW315-LS t1VwS NOilVNnS s4 VlnoVs 11 N.VIVs U0I4pNm s3lnaow (ll) H011(=l ZI/4 'loll oZZ '3nzi1 oL91 0 = „9l/£ :31't7OS =100N=100N 1St>3 (I) N'v-lrJ Sl OON 3SnOH -lVllNV.=l cdll> �Nlddvo mala `tom r r 3' n GROUND 1 O ROOF — ———— ACCESS SUN 'tion sd..,.n•rwom n: ❑ ❑ ❑ ❑ ❑ SUNATION SOLAR SYSTEMS VENTILATION-IS"- Ill REMINGTON BLVD. RONKONKOMA N.Y 11119 VENTILATION Ie'- (II)Pv MODULES NSTALLE 43�� INSTALLER NUMBER CUSTOMER INFO i0 ZUNIGA RESIDENCE vvv 15 WILD CHERRY WAY g g SOUTHOLD 11911 y V T e AC ESS j j JOB NUMBER -" vvv `• 191736 DATE 1.22.20 NOTES \ I N/A (I5)Pv MODULES- ACCESS ROOF O FRONT OF HOUSE-FACING STREET DRIVEWAY R324.1 ACCESS AND PATHWAYS-ROOF ACCESS,PATHWAYS AND SPACING REQUIREMENTS FOR SOLAR PHOTOVOLTAIC SYSTEMS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R324.1.1 THROUGH R32416 EXCEPTION(5) 1, ROOF ACCESS, PATHWAYS AND SPACING REQUIREMENTS NEED NOT BE PROVIDED WHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED,OR WHERE VERTICAL VENTILATION TECHNIQUES WILL NOT BE EMPLOYED 2 DETACHED. NON-HABITABLE GROUP U STRUCTURES R3141.4 SINGLE RIDGE ROOFS-PANELS, MODULES OR ARRAYS INSTALLED ON ROOFS WITH A SINGLE RIDGE SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO 36 INCH WIDE(914MM)ACCESS PATHWAYS EXTENDING FROM THE ROOF ACCESS POINT TO THE RIDGE. ACCESS PATHWAYS ON OPPOSING ROOF SLOPES SHALL NOT BE LOCATED ALONG THE SAME PLANE AS THE TRUSS, RAFTER OR OTHER SUCH FRAMING SYSTEM THAT SUPPORTS THE PATHWAY. EXCEPTIONS) DRAWN BY I ROOFS WITH SLOPES OF 2 UNITS VERTICAL AND 12 UNITS HORIZONTAL(16.6 PERCENT)AND LESS 1 STRUCTURES WHERE AN ACCESS ROOF FRONTS A STREET, DRIVEWAY OR OTHER AREA READILY ACCES15LE TO EMERGENCY RESPONDERS MACCALLUM 3 ONE ACCESS PATHWAY SHALL BE REQUIRED WHEN A ROOF SLOPE CONTAINING PANELS,MODULES OR ARRAYS 15 LOCATED NOT MORE THAN 24 INCHES((.18MM) REVISION VERTICALLY FROM AN ADJOINING ROOF WHICH CONTAINS AN ACCESS ROOF DATE DESIGNER NOTE R32415 HIP ROOFS- PANELS,MODULES AND ARRAYS INSTALLED ON DWELLINGS WITH HIP ROOFS SHALL BE LOCATED IN A MANNER THAT PROVIDES A CLEAR ACCESS 31670 BOUCHARD FINAL PATHWAY NOT LESS THAN 36 INCHES(514 MM)EXTENDING FROM THE ROOF ACCESS POINT TO THE RIDGE OR PEAK,ON EACH ROOF SLOPE WHERE PANELS,MODULES OR Xxxxxx NIA NIA ARRAYS ARE LOCATED EXCEPTIONS) XXXX.X N/A N/A I ROOFS WITH SLOPES OF 2 UNITS VERTICAL AND 12 UNITS HORIZONTAL(1(..6 PERCENT)AND LESS xxxxxx NIA NIA 2. STRUCTURES WHERE AN ACCESS ROOF FRONTS A STREET, DRIVEWAY OR OTHER AREA READILY ACCES15LE TO EMERGENCY RESPONDERS SCALE R3241.6 ROOFS WITH VALLEYS-PANELS AND MODULES SHALL NOT BE LOCATED LESS THAN 16 INCHES(451 MM)FROM A VALLEY. N.T.S. EXCEPTION(S) I ROOFS WITH SLOPES OF 2 UNITS VERTICAL AND 12 UNITS HORIZONTAL(1(,6 PERCENT)AND LESS TITLE ROOF ACCESS PLAN R3241.1 ALLOWANCE FOR SMOKE VENTILATION OPERATIONS- PANELS AND MODULES SHALL NOT BE LOCATED LESS THAN 18 INCHES(451 MM)FROM A RIDGE OR PEAK Ex CN(�> A-2 I WHERE ERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED OR WHERE VERTICAL VENTILATION METHODS WILL NOT BE EMPLOYED BETWEEN THE UPPER MOST PORTION OF THE SOLAR PHOTOVOLTAIC SYSTEM AND THE ROOF RIDGE OR PEAK. 2 DETACHED GARAGES OR ACCESSORY STRUCTURES. D Af? �5 `G�pEI K. C �q 02 jo I F-_____ __ OF NE GROUND ACCESS SUNatiol� SUNATION SOLAR SYSTEMS Ill REMINGTON BLVD RONKONKOMA N.T.IIll9 / NSTALLE 4355 ROOF CIRCUIT T __________ _ INSTALLER O ACCESS � NUMBER -36°- CUSTOMER INFO ZUNIGA RESIDENCE / 15 WILD CHERRY WAY SOUTHOLD 11911 0 El E JOB NUMBER 1913(0 VENTILATION - IS - DATE VENTILATION - 18" - - CIRCUIT 1 1.22.28 NOTES O 1 NIA >FI ............ \ Q Q \ \ Z Z / W W \.\ vALEY .... .............. vA EY ACCSS AC ESS ) �. ........... i DRAWN BY ANTHONY BOUCHARD \ - / REVISION DATE DESIGNER NOTE \ j 31620 BOUCHARD FINAL XX XX. NIA NIA CIRCUIT IAccEss (B) >OCXX Xx NIA NIA ROOF (EXT.) XXXX NIA NIA �� SCALE O Ds N. 0 t.S. / IQ+ c TITLE-ENPHASE CIRCUIT DIAGRAM A-3 FRONT OF HOUSE - FACING STREET, DRIVEWAY =il =3 WVN%VIO 3Nn-3NO 31111 'STN 3,,76 ONVHOn06.LNOHINV LG NIIVNO ,9 „04'0 09 'HOS OAd l 9 03 9 "a „4Z'I 09 'HOS OAad £ 9 Z-NMHJ S ,Z „4Z'I 09 "HOS O/kd I 9 03SD/Oq ,Z „4Z'1 09 HOS OAci £ g Z-NMH b 4£ „4Z'I 08 'HOS OAcI I 9 03q/OjD ,4£ „4z'I 08 'HOS OAcd tr 01 Z-NMH1 £ ,0z „4Z,I V/N t, 01 9+OZ WN 3d-Q Z ,41 „4Z 1 V/N b z 9-19V'O-0 39V'HdN 1 HIVN31 3219 3="l 13>4010n4NOO 3vnvv 1 3d-L1 ZI01OndN00 3a0?1103"13 NnN 11naN00 11naN00 =iO J39Wf1N ZIOlOnaNOO Z40 N0I1dINOS3a 9V'1 VNIdNnONV ONicrin9 3inciHOS ?1010naN00 (3NV lln(3N00 T I g (d L1>IIVN o1 1311VNVd NI S?J31?J3ANI-0N71W O3H7,i1,7%3 Sn-Z-LL-6nn IL01 3SVHciN3(£I) 13NVd L _ __ __ /nl dd-N0L£-1XN9M0.J VINV 109(£I) 37InN36 NIVW I r — 1 d0 1n�NID J 61, I I I ¢ I .LOnN3 I z lnOr110 V/N I I I 3SVHdN3 I -nvm NOIN31X3 I ' S31ON L Vol dZ I I OZ Zz I U I I 7v 31Va I 71V SILL NIW 9�L l6 l V09 NIW VBY 1 . . . . . . . a31,N 37IAN39 V'ez ciz N39wnN Sof 3an6olON3 U £I ZI 1311VNVd NI 6.J31N3nNl-ON01W Z I NVbel c1Z Sn-L-LL-SnndL01 36VMdN3(£I) 11-G.11a�OHln09 d00L �IO3,nV105 /M Od-N0L£-1XN3m0d V21V109(£I) .I.V M LNN3H0 o11m 4L U aalNnoW BOON do lnoalo z 30N3a193a V tDlNnZ Nvd N313W laNvd N3NI6W07 01 0111, 31nOOW nd Ol 1X3N 031,701 I lln�al� OiNI N3W016n7 173NN07SIO ON073S 13NVd 371/�N3S L i0 I ry NIVW NI 031V7O1 ��/� 2i39WnN 173NN07S10 SOIAN96 173NN00610.LNvWIN ('dAl) (e N3TVISNI 3nOVld (NMOMnH6 X09-f 31n00W V C3N3SAN Old V N 631 V/J10,) (dAl) W L i0 L 7G 70 N31N3ANI N01103NN07 173NN07510 371nN35 --- -- ON71W 6LLI1 AN VWO�INO�N 3015 A1ddnS 35VHdN3 0^19 NOl%NIW3N ILI 3n0Vld 6W31SA6 NV106 NOI1VNn8 . ill was U O 14 eN(M 3 xlnunLinun N SUNation TAG LABEL QTY. LOCATION NOTE EXAMPLES SUI'll SYSTEMS I71 REMINGTONGTON BLVD RONKONKOMA N.Y.II719 80¢a+4.2014,tEce•o311(clt» I A EVERY SEPERATION BY ENCLOSURES/WALLS/ O • t� • 12 CONDUITS --� NYSERDA PARTITIONS/CEILINGS/FLOORS OR NO MORE THAN 18' INSTALLER �3�� OA NUMBER 4W329 2014 NEC aW 33(E)M "- CUSTOMER INFO AW S — 7 ZUNI . RESIDENCE DO NOT 0000NNECT I SPLICE/COMBINER 1 0 ANY COMBINER BOX IF USED UNDER LOAD___ J 15 WILD CHERRY WAY SOUTHOLD 11911 " JOB NUMBER CIRCUIT 1 SIIMn..a SaW inln„ 91 . . . DATE 16.73 CIRCUIT 2 240.0 su1,: ;,sv 1.22.20 ^>7509454 I OF EACH A AC DISCONNECT i WA NOTES O2 SOURCE CIRCUITS COMPLETE VOLTAGE AND CURRENT VALUES ON DISCONNECT LABEL AS NEEDED 31.46 D AR 240.01 s0£'102 2014 NEC 690 t 71E) EL K. Service Disconnect - WARNING I AC SERVICE I OF EACH A FUSED AC DISCONNECT OELECTRIC9HOCK11A2ARD DISCONNECTING COMPLETE VOLTAGE AND CURRENT VALUES ON • OONO710UC34IE%*wS MEANS DISCONNECT LABEL 79011111ML•ON IM 711E look MOik }- LOAD 90E1 MI1Y E F11�d0171`-0 .I Mi i N' yv . N TIE OPBI.OIIMN G - -- ,3 (P�� o �O . F OF NES Thio Bufld,n;i.".Qwpped� rCpProdn Scarce ty!calcarto veRwre - e..w •carr rwe... M.r r wart. car ur •.n caw Q '� I MAIN DISCONNECT I OF EACH BUILDING MAIN DISCONNECT PANEL �a. �so-�sss PANEL .S>�m �e T1rit BuNdaq h•qulppwd we"an DRAWN BY Inbll'CpwNCMd Ewelm Powar Ptoduahmn Saurcw ANTHONY BOUGHARD II 1 1 O s.M.,PteteUTILITY METER 1 A PSEQG UTILITY METER E — SCALE N.T.S. ....w aw.w r.w.. re.r r war au art awr�: w.�.r....w..>..ire•.•... TITLE LABELING SCHEMATIC sat-sso-s�sa L- 1 SUNation ^I SUNATION SOLAR SYSTEMS 441 ,a,, Ill REMINGTON BLVD .. ..` _ , RONKONKOMA N.Y. II119 NY5ERDA /) •* INSTALLER 4 NUMBER CUSTOMER INFO _ ZUNIGA RESIDENCE hd + 15 WILD CHERRY WAY _ Wiz." �r------..._.._;_>:v t •y`.' «sh., ;4�� SOUTHOLD 11911 A a a JOB NUMBER Wild Cherry Way Ao DATE ki 1.22.28 NOTES I N/A Al k IL l ARRAY LOCATIONS ARRAYLOCATIONS SATELLITE IMAGE `y,���V°A o�h►i� VIA ROOF VIA GROUND a BAI OF 0 a _.5 — Y i ; DRAWN BY ANTHONY BOUCHARD SCALE N.T.S. SOUTH VIEW PROPOSED EXISTING METER TITLE PHOTOS VIA ROOF INVERTER LOCATION AND MDP G- 1 SOLARI Solaria PowerXT) Residential t .I �`\'�� a?�" YL F3.';�g.] j}c°"a �ayf..�.,F .r•�J d'�y^:1a .�l j�� tl °` y .. p 3 x•.. ;�:..�.�..a..� :.sem:.._... �_"..,_„���..._,.�. .""_. ..,.,w.:_«._�..�..�,,�. 3 Achieving up to 20% efficiency, Solaria PowerXT solar modules are one of the highest power modules in the residential solar market. Compared to conventional modules, Solaria PowerXT modules have fewer gaps between the solar cells, this leads to higher power and superior aesthetics Solaria PowerXT residential modules are manufactured with black backsheet and frames, giving them a striking appearance. Developed in California, Solaria's patented cell cutting and module assembly takes processed solar wafers and turns them into PowerXT solar modules The process starts by creating a highly reliable PowerXT cell where busbars and ribbon Interconnections are eliminated Solaria then packages the cells into the PowerXT solar module, reducing inactive space between the cells All of the above leads to an exceptionally efficient solar module produced in a cost effective manner. Higher Efficiency, Higher Power Solaria PowerXT modules achieve up to 20%efficiency,conventional modules achieve 15%—17%efficiency Solaria PowerXT modules are one of the highest power modules available Lover System Costs Solaria PowerXT modules produce more power per square meter area This reduces installation costs due to fewer balance of system components. Improved Shading Tolerance Sub-strings are interconnected in parallel,within each of the four module quadrants, which dramatically lowers the shading losses and boosts energy yield. Improved Aesthetics Compared to conventional modules,Solaria PowerXT modules have a more uniform appearance and superior aesthetics Durability and Reliability Solder-less cell interconnections are highly reliable and designed to far exceed the industry leading 25 year warranty About Solaria Established in 2000,The Solaria Corporation has created one of the industry's most respected OQ pV-RFO%, 2018 FA, IP portfolios, with over 100 patents encompassing materials, processes, applications, — .. products,manufacturing automation and equipment.Headquartered in Fremont,California, oNvGL Solaria has developed a technology platform that unlocks the potential of solar energy ' TUVRheinland PV MODULE allowing it to be ubiquitous and universally accessed RELIABILITY SCORECARD Precisely Right The Solaria Corporation 6200 Paseo Padre Parkway,Fremont,CA 94555 P (510)270-2500 www solaria com Copyi ight©2018 The Solaria Corporation Product specifications are subject to change without notice Rev 1 H 08-22-2018 SOLARI �- Solaria PowerXT"-I-3608-P Rd"` r:ti,'.'X^ x �;:u �..k': eri-�;Irv1};Ai�c4:,,. •".,_-,..,,.,. -........W.. .....wa_a.. A. g i»�. ,°. °zai. s ...�...___ a. _. Solaria PowerXT 345R-PD 350R-PD 355R-PD 360R-PD Cell Type Monocrystalline Silicon Max Power(Pmax) [W] 345 350 355 360 Dimensions(L x W x H) 1621 mm x 1116m x 40mm Efficiency [%] 19.1 19.4 19.6 19.9 Weight 21 kg/46 Ibis Open Circuit Voltage(Voc) [V] 46.9 47.1 47.4 47.7 Glass Type/Thickness AR Coated,Tempered/3.2mm Short Circuit Current(Isc) [A] 9.46 9.49 9.53 9.56 Frame Type Anodized Aluminum Max Power Voltage(Vmp) [V] 38.5 38.8 39 1 39.5 Cable Type/Length 12 AWG PV Wire(UL)/1000m Max Power Current(Imp) [A] 8.93 9.02 9.09 9.13 Connector Type Amphenol H4(MC4 compatible) Power Tolerance [°i°] -0/+3 -0/+3 -0/+3 -0/+3 Junction Box, IP67/4 diodes ------ � ;--- Front Load(UL 1703) 5400 Pa/113 psf* � g • � � - Rear Load(UL 1703) 2400 Pa/50 psf* Max Power(Pmax) [W] 255 259 261 265 Refer to Solaria Installation Manual for details Open Circuit Voltage(Voc) [V] 441 44.3 44.6 44.8 ...... - - - Short Circuit Current(Isc) [A] 7.66 7.69 7.68 7.71 �--------�--.-•---_--_ � �' `��- °- ------�- '`°`°°-° - Max Power Voltage(Vmp) [V] 35.4 35.7 36 0 36.3 Certifications UL 1703/IEC 61215/IEC 61730/CEC Max Power Current(Imp) [A] 7.15 7.22 7.27 7.30 CAN/CSA-C22.2 Fire Type(UL 1703) 1 1 ' ;a� C Power&Product Warranty 25 years* NOCT [°C] 45+/-2 *warranty details at www solaria com Temp.Coeff.of Pmax [°i°/°C] -0.39 i °'�"`," . •: ° Temp.Coeff of Voc I%/°C] -0.29 Stacking Method Horizontal/Palletized Temp.Coeff.of Isc [°i°/°C] 0.04 Pcs/Pallet 25 Pallet Dims 1668 x 1150 x 1230 mm Operating temperature [°C] 40 to+85 Pallet Weight 590 kg/1300 lbs Maxallets/40-ft Container 28 ax System Voltage [V] 1000 Pcs/40 ft Container 700 Max Fuse Rating [A] 15 Bypass Diodes [#] 4 10 --- -- --1000W/M2 --- J'5.a1oj_ 15 e., 9 - - ----- i 1a9mm Hamm D > 800 W/m2 [gym i A a a A i 7 - - ( = I g 5 - - i- -- 600 W/m2 ----- I Z ' 7116-- I ✓� 5 11 i W 5 -W-IM- 400 W/m2 4 Y 274 - - - - j I 200 W/m2 NEAV2 %)-1) POSMVE(+1 1000 33 1000(3 3 ft) 0 �_ I 0 5 10 15 20 25 30 35 40 45 50 l; VOLTAGE(V) [3m)- 25mm I A B A Authorized Dealer 1 I,_[,5oan1 �: [a5s°.,_________--_^� 382mm •, o00mm \-7-[0276.1 x iomm[4Ssd1°] t asmm[o=a)TBRu aLL U MOUNTING SLOTS W AY GROUND W 10 o run t� 7mm ]D.39m P [0.3m] °----�-, 4D_Dmm ,(1 Oram Moulmus1toLE tetlTm 1.7mm --�M�350mm �W [0.411] The Solaria Corporation 6200 Paseo Padre Parkway,Fremont,CA 94555 P (510)270-2500 www solaria com Copyright©2018 The Solaria Corporation Product specifications are subject to change without notice Rev 1 H 08-22-2018 Enphase Microinverters -(4,n,-AM[ RIC WS The high-powered smart grid-ready Enphase Enphase IQ JX Micro'" dramatically simplifies the IQ 7X Microinverter installation process while achieving the highest system efficiency for systems with 96-cell modules. Part of the Enphase IQ System,the IQ A Micro integrates with the Enphase IQ Envoy'', Enphase IQ Battery", and the Enphase Enlighten'" monitoring and analysis software. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) Efficient and Reliable • Optimized for high powered 96-cell*modules • Highest CEC efficiency of 97.5% More than a million hours of testing • Class II double-insulated enclosure • UL listed Smart Grid Ready • Complies with advanced grid support,voltage and frequency ride-through requirements • Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) U *The!Q 7X is required to support 96-cell modules. EN PHAS E• To learn more about Enphase offerings,visit enphase.com Enphase IQ 7X Micr®inverter INPUT DATA(DC) IQ7X-96-2-US and IQ7X-96-B-US Commonly used module pairings?�-�_ 320 W-460 W+�-""__�._.......�.�..._.....__..,.._.....�........_...-,.w.__._._.�...,.,...u___�._._..__...._....__.....__.__.___........_M._,..�....�.-.._._� Module compatibility 96-cell PV modules Maximum input DC voltage 79.5 V Peak power tracking voltage 53V-64V Operafing range 25V-79,5V Min/Max start voltage 33 V/79 5 V Max DC short circuit current(module isc) 10A overvoltage class DC port II DC port backfeed current 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) @ 240 VAC @ 208 VAC Peak output power 320 VA Maximum continuous output power 315 VA Nominal(L-L)voltage/range2 240 V/211-264 V 208 V/183-229 V Maximum continuous output current 1 31 A(240 VAC) 1 51 A(208 VAC) Nominal_frequency 60 Hz Extended frequency range 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms Maximum units per 20 A(L-L)branch circuit3 12(240 VAC) 10(208 VAC) Overvoltage class AC port III AC port backfeed current 18 mA Power factor setting 1.0 Power factor(adjustable) 0 85 leading. 0 85 lagging EFFICIENCY @240 VAC @208 VAC " CEC weighted efficiency 97.5 io 97.0`YQ w .�. M. MECHANICAL DATA Ambient temperature range -40°Cto+60°C Relative humidity range 4%to 100%(condensing) Connectortype(IQ7X-96-2-US) MC4(or Amphenol H4 UTX with optionalQ-DCC-5 adapter) Connector type(IQ7X-96-13-US) Friends PV2,may require adapters for modules with MC4 or UTX connectors. -PV2 to MC4:order ECA-S20-S22 -PV2 to UTX order ECA-S20-S25 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2 38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690_ Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 69012 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.Seethe compatibility calculator at haps://enph se,�pm/en-U.i/supportlmooule-cpmRgtlbtlity 2 Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com EN PHAS E. O 2018 Enphase Energy All rights reserved All trademarks or brands used are the property of Enphase Energy,Inc 2018-11-19 MMIM 4 x MWIl e _ ., '" C .., 3 �, ~`•yam �„G..rw+� _ = _: mow, �.�':. ,.�''r`,ks rte. :'�,.c .+, ��,7..' '•�w Entire Mounting System from Snap in features make the ngle Manufacturer .under 1 install process intuitive Siand Warranty fast Industry Leading. Technical' The Most Comprehensive UL Support Services for Every' U� 2703 Listing in the Industry Customer The SnapNrackSerwleslOORoof. Mount System residentialis designed to provide the lowest totalinstall cost of �any • • ills IL Thetop-of-the-line features of the SnapNrack mounting system reduce install times and labor cost while eliminating the need for service calls creating the lowest install lifecycle cost of any mounting system. Wire Management - _ • Products such as the standard rail channel keep wires neatly organized providing a clean finished look to every install • Industry's largest offering of wire management accessories include snap in junction box, 4-wire and trunk cable clamps, as well as conduit clamps for both composition shingle and _- tile roofs. Undeniable Aesthetics • Render the mounting system invisible by using Universal End Clamps that fasten modules while remaining hidden underneath the array • Array skirt provides a sleek look and attractive design to the front of the array • Rail-based system provides rigid structure tucked away underneath array with no unsightly mounts at the top or bottom , Gu • flt ' Performance . Innovatiomp, Snap,Nrack solutio,ns are focused on simplifying the insta[lation experience throu:gh intuitive Products and the best wire manaqernelnt in theibdustry. solar Mounting Solutions . • • • contact@snapnrack.com 20oUnUng Soluticyns.All rights reserved t t Series 100 Snapl ,'rack- Solar Mounting Solutions Flashed L Foot A � S � Reliable & Weatherproof Roof Attachment Cutting of shingles not Preasselm.bled, snap-in required 4PV hardware reduces instal,, ation . . ..1 instaflation, using Included . . UL . . . . 1/2 socket 2703 Listing RESOURCES snapnrack.com/resources _. DESIGN snapnrack.com/configurator WHERE TO BUY snapnrack.com/where-to-buy -Sna.pNrack Series 100 Flashed L Foot Kit is an industry-leading, weatherproof solution for attaching to composition shingle roofs. The Flashed L Foot provides a fully flashed method for mounting the SnapNrack Series 100 system. The combination of Series 100 and the Flashed L foot is guaranteed to improve labor times and ensure the highest quality install possible. Flashing • Available in black galvanized steel or aluminum for enhanced corrosion resistance • L Foot is attaches to bottom edge of flashing, removing the need for shingle cutting zy. Z*' • Innovative stamped features provide increased rigidity `` L Foot • Engineered for maximum adjustability with the ability to orient in any direction Vertical adjustability up to 3" using available spacers �.p L Foot Base .olop • Provides a long lasting watertight seal over the life of the system that does not rely on rubber (elastomeric zi seals) that will degrade over time • Easily installs with off-the-shelf lag screws x. Channel Nut Provides snap-in installation to the rail channel with no ZP , drilling required Wide range of adjustability due to sliding ability in rail prior to final tightening Q,Ua I 'l ity, Performance. Innovati.. on-1 ® ® . - . .. ucts s best wire management SnapNrack- Solar Mounting Solutions . • www.snapinrack.com . . . . ® ® . . �resarvod