Loading...
HomeMy WebLinkAbout45104-Z g�f lk ��o�U CpG�ti, Town of Southold 9/27/2020 P.O.Box 1179 C5 o _ 53095 Main Rd dp app'� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41470 Date: 9/27/2020 THIS CERTIFIES that the building GENERATOR Location of Property: 1530 Camp Mineola Rd,Mattituck SCTM#: 473889 Sec/Block/Lot: 122.-5-3.5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/7/2020 pursuant to which Building Permit No. 45104 dated 8/13/2020 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"accessory generator as applied for. The certificate is issued to Smith,Ronald&Hession,Ann of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 45104 9/22/2020 PLUMBERS CERTIFICATION DATED 1 Au h ' d Signature z 7 TOWN OF SOUTHOLD ay BUILDING DEPARTMENT r o TOWN CLERK'S OFFICE o . SOUTHOLD, NY NI BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45104 Date: 8/13/2020 Permission is hereby granted to: Smith, Ronald & Hession, Ann 1530 Camp Mineola Rd Mattituck, NY 11952 To: legalize "as built" generator as applied for. At premises located at: 1530 Camp Mineola Rd, Mattituck SCTM # 473889 Sec/Block/Lot# 122.-5-3.5 Pursuant to application dated 7/7/2020 and approved by the Building Inspector. To expire on 2/12/2022. Fees: AS BUILT-ACCESSORY $200.00 ELECTRIC $170.00 CERTIFICATE OF OCCUPANCY $50.00 Total: $420.00 6WWglihis`­pector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains Iess than 2/10 of I% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swinuning pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. "I - 1- Oc aO New Construction: Old or Pre-existing Building: v (check one) Location of Properly: j� l off z \mU' P6 House No. Sri ettHamlet Owner or Owners of Property:�(o �r 3cc\A Y \ Suffolk County Tax Map No 1000, Section 1 a a Block Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for. Temporary Certificate Final Certificate: (check one) Fee Submitted: $ 9-6041?'Iet� Applicant Signature I OF SOUry®! Town Hall Annex ~ G Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 • o sean.devlin(,5-town.southold.nv.us Southold,NY 11971-0959 �lyC®UNTV BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Ronald Smith Address: 1530 Camp Mineola Rd city Mattituck st: Ny zip: 11952 Building Permit#: 45104 Section: 122 Block: 5 Lot 3.5 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Platinum East Electric License No: 34091 ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Generator X INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200a A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceding Fan Combo Smoke/CO Transfer Switch 100A UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures 11 Pump Other Equipment: 20kW Kohler Generator w/ 100A Overcurrent Protection on Generator, Transfer- Switch in Basement of Main House, Generator Located Behind Pool House Notes. Generator Inspector Signature: Date: September 22, 2020 S.Devlin-Cert Electrical Compliance Form.xls �a0F SOUlyo Lis I O LI - `1 5'-�O �f - �-- ✓ # # TOWN OF SOUTHOLD BUILDING �yco � 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION f ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: ~ s L6 R OaA P/0,n�c-, r rho �/,l %-903 t C�- DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(IST) -------------------------------------- FOUNDATION(2ND) ROUGH FRAMING& PLUMBING y � 1 r INSULATION PEA N.Y. STATE ENERGY CODE ' 3 FINAL A DVITIONAL GQMMENTS 1 O rn i ' H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined 20 CKU Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved _4[3 20 Mail to: Disapproved a/c Phone: Expiration I all ,20 -Igcc U 1 But ng Inspect JUL — 2020 APIRLWATION FOR BUILDING PERMIT \ ncl BUILDING DEP-, Date ` , 20 CQ fINSTRUCTIONS OI�7�'L:t D a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept,on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department'for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions,or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections a C9K�X ?,(-- 6 �1�� (Signature of applicant or name, if a corporation) 7� , 4,A, Nailing address of applicant) State whether applicant iq owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License Plumbers License No. Electricians License No. 64bq Other Trade's License No. 1. Location of land on which proposed work will be done- House Number Street Hamlet l County Tax Map No. 1000 Section Block Lot �� Subdivision Filed Map No. Lot 2. State existing use and occupancy of preises and int nded use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work QQnoI (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear -Depth.., Height Number of Storiesj ' ' e 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises Address Phone No. Name of Architect Address Phone No Naive of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) being duly sworn, deposes and says that(s)he is the applicant (Naive of individual signing contract) above named, (S)He is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work.and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of 20 r Notary Public Signature of Applicant FF BUILDING DEPARTMENT- Electrical Inspector ��O CPG TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 0 • Southold, New York 11971-0959 p� Telephone (631) 765-1802 -'FAX (631) 765-9502 roper.richert(cD-town.southold.ny.us APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: 14z I T I1- Date: -� Company Name: —IV VA4 jFMT ' C e(To f QC Name: ke-i T+ License No.: f: email: 0144igvA7 I L41 boo .Cetj Address: 13ao tecy�Y` S0 UTtfoC Phone No.: i - . S- JOB SITE INFORMATION: (All Information Required) Name: Address: A0 Cross Street: Phone No.: &?i- rns-ly2 Bldg.Permit#: /0 email: D146,10,4i t4 Sj - V 0.1roA Tax Map District: 1000 Section: I o�crxl Block: t) L T JA BRIEF DESCRIPTION OF WORK (Please Print Clearly) Circle All That Apply: Is job ready for inspection?: Y / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required). Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground -Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection FormAs � FF04 BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD - Town Hall Annex- 54375 Main Road - PO Box 11,79 .�- • Southold, New York 11971-0959 dpi Telephone (631) 765-1802 - FAX (631) 765-9502 ro-ger.richert(cDtown.southold.ny.us APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: 1<4,ITl+- Date: Company Name: —41 V Name: ke-rTf License No.: 3 yoql _ N, email: 01441n„ es 2 CoQ • Address: 13.10 (ee-r-K& So u-F46 t Phone No.: 631 - 96 S_ JOB SITE INFORMATION: (All Information Required) Name: rt Pq I P Once- Address: Al A Cross Street: Phone No.: 21- rKS-I Y2 Bldg.Permit email: ��4 A, a � oa.at Tax Map District: 1000 Section: I o77 Block: BRIEF DESCRIPTION OF WORK (Please Print Clearly) 6 t GSA T� Circle All That Apply: Is job ready for inspection?: Y / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On. Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect-Service Reconnected - Underground -Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION Request for Inspection Form.As Mise liz,k� J ' SURVEY OF: O PROPERTY LOCATED AT -MATTITUCK LAND N/F _T c TOWN OF SOUTHOLD DARLA A LAND N/F � ! TOWN COUNTY, NEW YORK PIPE DOORHY OLE JULE LANE 0 j HOMEOWNERS ASSOCIATION O S.C.T.M. #'' 1000-122-5-3.5 „� I CORP Z z m AREA = 81.689.7 SF. = 1.88 ACRES 2'/E • FENCE t S 81'07'40' �- u � °o 0 SCALE: 1"=40' 344.99, E Y N �p MIRE FENCE Z_I (/? N ! �1 OLL C NOTE: THE EXISTENCE OF RIGHT OF WAYS. l•ENERATOR0 I IL I 7p WETLANDS -AND/OR EASEMENTS OF RECORD cv IF ANY. NOT'SHOWN ARE NOT GUARANTEED. POOL ' { EQUIP B 0 m 26.7 m FENCE CD m POOL NOTE: WATER SERVICE o "' HOUSE m e AND SEPTIC SYSTEM LOCATION �' N 16.6 N BY OTHERS. B.O.H. REF. No. W BB m w 80 SEPTIC LOCATION .e- GRAVEL D IVEMAY _ O { 1 v ' GAREAN I s RELLIS A' LP LPI -A- -B- N 29.0' ; i PATIO 22.0 S.T. 32' 27' of sT � O SHED ` o �` 4.5 ?u L.P.1 38' 30.5' LAND N/F z14.4 ; < P o o < 2 SANITARY TY RES. a Z 'L.P.2 22' 15' ROBERTA M a a - a w d'POOL HOUSE KALOUS i r 3y q i PATIO c Suffaxsi Gil+ eCH -vEXISTING" � O UNCHANGED CHANGED SEPTIC OVAL OF` O WO "Q SYSTEM SCDHS ' ^y LA IE;?,- ,MA WLY w1 ANO APPROVED-5/25/2006 O, < h �= h O 5 co 46-7 - .f'� N STI Rete '.1U 102 r1:S,f'te€.iia.f`(J'_`` �DF�AiN BALC 3 3 0 o W N Y <' O (V J� r i PORCH POSE'-MIRE m y� 13.6 �O�M�{169t+Q3e1 3ihtl' f pytl 15.8FENCE as co [�� Cbd'�id/CI x:18 Qwom tub"* �011�1b m 121p u 81.0' ^I be � C/� 'p'• FiFEa FR A N' 25.6 p JWo<p r ^i G�s OOUTDOR RAS EV RTICK NSHOIOPORCH PA FENCE 34NWATER LO9.4'/NCiciry KnePPer, P.C., Chief POST 9.5NRE SERVICE CEUNIT GRAVEL fly 00 IL I FENCE N L0 o n f, p' SURVEYED BY: PAUL BARYLSKI LAND SURVEYING - OAKDALE NY 11769 N 8253'00"yyPHONE 631-294-6985 631-294-6985 352.15' FAX 631-627-3186 ! DRIVE. PAULBARYLSKIQYAH00.COM O.L. FEBRUARY 14. 2020 Of N IV LAND N/F ea )_ STE1(EN o QAv ls�� O UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION B E'R G E R to OF 709 P RTE EDUCATION LAN. COPSTGFTHOHYKG y THE LAND SURVEYORS INKED I E SED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. _ O CERTIFICATIONS EYINDICATEDPRE HEREON SHALL RUN ONLY TO FOR WHOM THE SURVEY IS PREPARED.AND-ON HIS BEHALF TO I 0 � � TITLE COMPANY.GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREOK•ANO TO THE ASSIGNEES OF THE LENDING INSTITUTION. 2 o5 ``' GUARANTEES OR CERTIFICATIONS ARE NOT TRANSFERABLE TO ADDITIONAL KRA USE s�0 679Z t�J+tr INSTITUTIONS OR SUBSEQUENT OWNERS. * ROAD LAND S 3680 Cori A�AEPRIIEID AS-NOTED DATB.P:#FEE: BY. NOTIFY, BUILDING DEPARTME AT ELECTRICAL 765-1802 8 AM TO 4 PM FOR THE INSPECTION REQUIRED FOLLOWING•INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2-:ROUGH',­FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR CO. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT-RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS, COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF SETH BOARD S 0_UT HOLD T RUSTfES OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY ' f 1 odels: 20RESB KOHLER. Power Systems LPG/Natural Ga Fuel Ga l s 9001 Standard-f=eatures • RDC2 Controller titA NATIONALLY REGISTERED o One digital controller manages both the generator set and transfer switch functions (with optional Model RXT transfer switch) o Designed for today's most sophisticated electronics o Electronic speed control responds quickly to varying household demand o Digital voltage regulation protects your sensitive electronics from harmonic distortion and unstable power quality o Two-line, backlit LCD display with adjustable contrast is easy to read,even in direct sunlight or low light • Kohler Command PRO Engine Features o Kohler Command PRO®OHV engine with hydraulic valve lifters for reliable performance without routine valve The Kohler® Advantage adjustment or lengthy break-in requirements • High Quality Power o Powerful, reliable air-cooled performance Kohler home generators provide advanced voltage and o Simple field conversion between-natural gas and LPG frequency regulation along with ultra-low levels of fuels while maintaining emission certification harmonic distortion for excellent generator power quality to o Aluminum Sound Enclosure and Skid protect your valuable electronics. o Wind rated up to 181 mph , . • Extraordinary Reliability o Weather-resistant cashmere textured finish Kohler is known for extraordinary reliability and performance and backs that up with a premium five-year or • Designed for Easy Installation 2000 hour warranty. o ,Hinged,locking roof • Perfect for Tight Lot Lines o Fuel and electrical connections through the enclosure wall Can be placed as close as 18 inches from your home or eliminate the need for.stub-ups through the bottom small business,providing installation flexibility even on o, Load connection terminal block allows easy field wiring smaller lots.* o Designed for outdoor installation only • Powerful Performance • Certifications Exclusive PowerBoost" technology provides excellent o Meets emission regulations for U.S. Environmental starting power. Protection Agency(EPA)with both natural gas and LPG- • Fast Response Note: CARIB does not regulate emergency standby Kohler's unique Fast-Response"" excitation system generators with outputs less than 50 HP, Only the EPA delivers excellent voltage response and short-circuit standards apply. capability. o UL2200 listed (60 Hz modeo • Quiet Operation o CSA certification available (60 Hz model) Kohler home generators provide quiet,neighborhood- . Warranty friendly performance. o 5-year/2000 hour warranty for on-grid (standby) applications in locations served by a reliable utility source Generator Ratings Standby Ratings Natural Gas LPG Model Voltage Phase Hz Alternator kW/kVA Amps kW/kVA Amps 20RESB 120/240 1 60 2F7 18/18 75.0 20/20 83.3 115/230 1 50 2F7 14/14 60.8 15/15 65.2 RATINGS,Standby ratings apply to Installations served by a reliableuhlRysource All single-phase units are rated at 1.0powerfactor The standby rating Is applicable to variable lcedswdhanaverage load factor of 80%for the duration of the power outage No overload capacity Is specified at this rating Ratings are In accordance with ISO-3046/1,BS5514,AS2789,and DIN 6271 GENERAL GUIDELINES FOR DERATING AL71TUDE•Derate 4%per305 m(10001[)elevation above 153 in(5001[).TEMPERATURE.Derate 21%per 5 5°C(10°F)temperature increase above 16'C(60"F) Availability is subject to changewRhout notice.Thegeneratorset manufacturer reserves the right to changethe design orspecificationswdhout notice and without any obligation or liabihtywhasoever Contact your local Kohler Co generator distributor for availability Check the appliance manufacturer's specifications for actual power requirements. Consult a Kohler®Paver Systems professional to calculate your exact residential power system requirements. Unless otherwise directed by local codes Generator must be located away from doors,windows,and fresh air intakes Seethe installation manual for guidelines G4-244(20RESB) 1/14 Alternator Specifications Alternator Specifications Alternator Features PowerBoost- Generator a Compliance with NEMA, IEEE, and ANSI standards for Specifications 1-Phase temperature rise Manufacturer Kohler / Output reconnectable 120/240 • Self-ventilated and drip-proof construction Type 2-Pole,Rotating Field • Vacuum-impregnated windings with fungus-resistant Leads,quantity 4 epoxy varnish for dependability and long life Voltage regulator Digital • Superior voltage waveform and minimum harmonic Insulation. NEMA MG1-1.66 distortion from skewed alternator construction Material Class H • Digital voltage regulator with.1.0%no-load to full-load Temperature rise Class H RMS regulation Bearing:quantity,type 1,Sealed Ball • Rotating-field alternator with static exciter for excellent- Coupling Direct load response Amortisseur windings Full • Total harmonic distortion (THD)from no load to full load with Voltage regulation,no-load to full-load a linear load is less than 5% RMS ±1.0% One-step load acceptance 100%of Rating Peak motor starting kVA 9 240\t 20RESB 405 L Application Data Engine Engine Electrical Engine Specifications 20RESB Engine Electrical System 20RESB Manufacturer Kohler Ignition system Electronic, Engine:model,type CH1000 4-Cycle Capacitive Discharge Cylinder arrangement V-2 Starter motor rated voltage(DC) 12 Displacement,cm3(cu.in.) 999(61) Battery(purchased separately): Bore and stroke,mm(in.) 90 x 78.5(3.54 x 3:1) Ground Negative - -- - ---- - --- -- -- - -12- -- ----- -- --- --- Compression ratio � 8.8:1 Volts Main bearings:quantity,type 2,Parent Material Battery quantity 1 Rated RPM Recommended cold cranking amps: 60 Hz 3600 (CCA)rating for-18°C(0°F) 500 50 Hz 3000 Group size 26 Max.engine power at rated rpm,, Lubrication kW(HP) LPG,60 Hz 23.0(30.9) Lubricating System 20RESB LPG,50 Hz 20.0(268) Type Full Pressure Natural gas,60 Hz 202(27.1) Oil capacity(with filter),L(qt)* 2.7(2.9) Natural gas,50 Hz- 16.8(22.5) Oil filter:quantity,type 1,Cartridge Cylinder head material Aluminum Oil cooler Integral Valve material Steel/Stelike® * Oil capacity for a new,dry engine. Piston type and material Aluminum Alloy Fuel Pipe Size Crankshaft material Heat Treated,Ductile Iron Minimum Gas Pipe Size Recommendation,in.NPT Governor:type Electronic 20RESB Frequency regulation,no load to full load Isochronous Frequency regulation,steady state +0.5% Natural Gas LPG Air cleaner type Dry Pipe Length, 281,000 340,000 Exhaust m(ft.) Btu/hr. Btu/hr. 1 (25) 1 3/4 - Exhaust System 20RESB 15 (50) 1 1 Exhaust temperature exiting the 30 (100) 1 1/4 1 enclosure at rated kW,dry,°C(°F) 260(500) 46(150) 1 1/4 1 1/4 61 (200) 1 1/4 1 1/4 G4-244 (20RE38) 1/14 Fuei Requirements RDC2 Controller Fuel System 20RESB Fuel types Natural Gas or LPG Fuel supply inlet 1/2 NPT Fuel supply pressure,kPa(in.H2O). I Fmq 60 0H Natural gas 1.2-2.7(5-11) t ® o LP 1.7-2.7(7-11) �®�o Fuel Composition Limits* Nat.Gas LPG •� Methane,%by volume(minimum) 90 min. Ethane,%by volume(maximum) 4.0 max. - Propane,%by volume 1.0 max. 85 min. Propene,%by volume(maximum) 0.1 max. 5.0 max. The RDC2 controller provides integrated control for the C4 and higher,%by volume 0 3 max. 2.5 max. generator set, Kohler®Model RXT transfer switch, Sulfur,ppm mass(maximum) 25 max. programmable interface module (PIM), and load control module Lower heatin value, (LCM). MJ/m3(Btu/tt ),(minimum) 33.2(890) 84.2(2260) * Contact your local distributor for suitability and rating derates based The RDC2 controller's 2-line LCD screen displays status on fuel compositions outside these limits. messages and system settings that are clear and easy to read, even in direct sunlight or low light. Operation Requirements Fuel Consumption RDC2 Controller Features Fuel Fuel Consumption,m3/hr.(cfh) • Membrane keypad Model Type %Load 60 Hz 50 Hz o OFF,AUTO,and RUN push buttons 100 8.0 (281) 6.4 (225) o Select and arrow buttons for access to system 75 6.9 (243) 54 (189) configuration and adjustment menus Natural 50 4.6 (161) 39 (139) • LED indicators for OFF,AUTO,and RUN modes Gas, 25 3.6 (127) 2.9 (103) • LED indicators for utility power and generator set source Exercise 2.0 (71) 2.0 (71) availability and ATS position (Model RXT transfer switch 20RESB 100 3.9 (136) 2.9 (102) required) 75 3.1 (109) 2.4 (85) • LCD display LPG 50 2.3 (82) 1.8 (63) o Two lines x 16 characters per line 25 1.7 (59) 1.3 (47) o Backlit display with adjustable contrast for excellent Exercise 1.0 (35) 1.0 (35) visibility in all lighting conditions Nominal fuel rating:_Natural gas: 37_MJ/m3(1000 Btu/ft.3)_ _•_Scrolling system status display LPG: 93 MJ/m3(2500 Btu/ft 3) o Generator set status LPG conversion factors: 8.58 ft.3=1 Ib. o Voltage and frequency 0.535 m3=1 kg o Engine temperature 36.39 ft.3 =1 gal. o Oil pressure o Battery voltage Sound Data o Engine runtime hours Model 20RESB 8 point logarithmic average sound levels are • Date and time displays 64 dB(A)during weekly engine exercise and 69 dB(A)during • Smart engine cooldown senses engine temperature full-speed generator diagnostics and normal operation. For • Digital isochronous governor to maintain steady-state speed comparison to competitor ratings,the lowest sound levels are at all loads 62 dB(A) and 67 dB(A)respectively.* • Digital.voltage regulation: -±-1.0%RMS no-load to full-load All sound levels are measured at 7 meters with no load. • Automatic start with programmed cranking cycle * Lowest of 8 points measured around the generator. Sound levels at • Programmable exerciser can be set to start automatically on other points around generator may vary depending on installation any future day and time,and run every week or every two parameters. weeks _ • Exercise modes o Unloaded weekly exercise with complete system diagnostics o Unloaded full speed exercise o Loaded full-speed exercise (Model RXT ATS required) • Front-access mini USB�connector for SiteTech' connection • Front access mini-breaker protects the alternator • Integral Ethernet connector for Kohler®OnCue"" • Built-in 2.5 amp battery charger • Remote two-wire start/stop capability for optional connection of Model RDT or RSB transfer switches See additional controller features on the next page. G4-244 (20RESB) 1/14 N KOHLER CO.,Kohler,Wisconsin 53044 USA Kohler Power Systems Phone 920-457-4441,Fax 920-459-1646 Asia Pacific Headquarters For the nearest sales and service outlet in the 7 Jurong Pier Road US and Canada,phone 1-800-544-2444 Singapore 619159 KOHLERPower.com Phone(65)62646422,Fax(65)6264-6455 Additional RDC2 Controller Features Available Options, Continued • Diagnostic messages Electrical System o Displays diagnostic messages for the engine,generator, ❑ Battery Model RXT transfer switch,programmable interface module (PIM),and load control module(LCM) ❑ Battery heater o Over 70 diagnostic messages can be displayed Fuel System • Maintenance reminders ❑ Braided stainless steel flexible fuel line • System settings o System voltage,frequency,and phase Literature o Voltage adjustment ❑ General maintenance literature kit o Measurement system, English or metric ❑ Overhaul literature kit • ATS status (Model RXT ATS required) ❑ Production literature kit o Source availability o ATS position (normal/utility or emergency/generator) Starting Aids o Source voltage and frequency ❑ Carburetor heater(recommended for • `ATS control (Model RXT ATS required) reliable starting at temperatures below 0°C[32°F]) o Source voltage and frequency settings ❑ Fuel regulator heater pad (recommended for o Engine start time delay reliable starting at-temperatures below-18°C[0°F]) o Transfer time delays Kohler®Automatic Transfer Switch o Voltage calibration o Fixed pickup and dropout settings ❑ Model RXT,see specification sheet G11-121 • Programmable Interface Module (PIM)status displays ❑ Model RDT,see specification sheet G11-98 o Input status (active/inactive) ❑ Madel RSB,see specification sheet G11-101 o Output status (active/inactive) ❑ Other Kohler®ATS • Load control module (LCM)menus Miscellaneous Accessories o Load status o Test function ❑ Generator Set Standard Features ❑ • Battery cables • EPA certified fuel system • Aluminum sound enclosure Generator Set Dimensions and Weights • Critical silencer Overall Size,L x W x H: 1215 x 733 x 802 mm • Field-connection terminalblock (47.9 x 28.8 x 31.6 in.) • Fuel solenoid valve and secondary regulator Shipping Weight(with aluminum enclosure) 240 kg(530 Ib.) • Line circuit breaker, 100 amps , • Multi-fuel system, LPG/natural gas,field-convertible • Oil drain extension with shutoff valve -0. . •' Premium five-year/2000 hour limited warranty • RDC2 generator set/ATS controller H • Rodent-resistant constructionam no • Sound-deadening,flame-retardant foam per UL 94, class HF-1 0 0 Available Options -- L W —►� Approvals and Listings NOTE Dimensions are provided for reference only and should not be used for planning pP g Installation.Contact your local chstnbutor for more detailed information ❑ CSA Approval DISTRIBUTED BY: Communication Accessories ❑ OnCues Generator Management System Controller Accessories ❑ Programmable Interface Module (PIM) (provides 2 digital inputs and 6 relay outputs) ❑ Load Control Module (LCM) (provides 4 power relays and 2 HVAC relays) ©2014 by Kohler Co. All nghts reserved G4-244(20RESB) 1114