Loading...
HomeMy WebLinkAbout43682-Z �o��FF�t'�coGy Town of Southold 9/5/2020 P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41293 Date: 9/5/2020 THIS CERTIFIES that the building AS BUILT ALTERATION Location of Property: 53930 Route 25, Southold SCTM#: 473889 Sec/Block/Lot: 61.4-19.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/19/2019 pursuant to which Building Permit No. 43682 dated 4/25/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"alterations to an existing one family dwelling as applied for. Corrected 9/5/2020 to say"as built"alterations instead of single family dwelling_ The certificate is issued to Olivanne LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 20-60707 3/4/2020 PLUMBERS CERTIFICATION DATED 7/1/2020 K Scanlon tho ' Si ature rY= �guEFO`,�CpG., Town of Southold 7/27/2020 O y� P.O.Box 1179 0 co 53095 Main Rd %IV Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41293 Date: 7/27/2020 THIS CERTIFIES that the building SINGLE FAMILY DWELLING Location of Property: 53930 Route 25, Southold SCTM#: 473889 Sec/Block/Lot: 61.4-19.1 Subdivision: Filed Map No. Lot No. I conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/19/2019 pursuant to which Building Permit No. 43682 dated 4/25/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as_built"alterations to an existing one family dwelling as applied for. The certificate is issued to Olivanne LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 20-60707 3/4/2020 PLUMBERS CERTIFICATION DATED 7/1/2020 ith Scanl %�c A Signature 1�. TOWN OF SOUTHOLD ����SUFFDt,Y�vGy BUILDING DEPARTMENT TOWN CLERK'S OFFICE o . SOUTHOLD NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 43682 Date: 4/25/2019 Permission is hereby granted to: Olivanne LLC 53930 Main Rd PO BOX 593 Southold, NY 11971 To: make alterations (as built - under construction) to an existing single family dwelling as applied for. At premises located at: 53930 Route 25 SCTM # 473889 Sec/Block/Lot# 61.-4-19.1 Pursuant to application dated 4/19/2019 and approved by the Building Inspector. To expire on 10/24/2020. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $400.00 CO -ALTERATION TO DWELLING $50.00 Total: $450.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains Iess than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property Iines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25.00, Swimming pool$25.00,Accessory building$25.00,Additions to accessory building$25.00,Businesses$50.00. /� Certificate of Occupancy on Pre-existing Building)- $100.00 4- c��e U J � C 2�4" 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. L9 _ L New Construction: Old or Pre-existing Building: r (check one) �j Location of Property: "1 s� 1"\ `t� 2,� ! Nq �'1 ` - House No. 1 - `, Street - n f r Hamlet � Owner or Owners of Property:s c � V �L �Jt �`-'� �IV l Suffolk County Tax Map No 1000, Section (Q Block 24 Lot , Subdivision Filed Map. Lot: ( Ci Permit No. 1 , -1 kQO_Date of Permit. S S�Applicant:S�,ts�'l \c & Lj -� Wealth Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted:$ rb Applicant Signature CONSENT TO INSPECTION the undersigned, do(es)hereby state: Owner(s)Name(s) That the undersigned(is) (are)the owner(s)of the premises in the Town of Southold, located atm-9z6 auj a A S-), -L 4�in n,LC,- . which is shown and designated n the Suffolk County Tax Map as District 1000, Section U ` ,Block ,Lot 1 ! c I That the undersigned(has)(have)filed,orcauseto be filed, n applicatio n the Southold Town B Tiding Inspector's Office for the following: `�((Q_ C(� OAL �n That the undersigned do(es)hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon,to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws, ordinances,rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections,do(es) so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances,rules or regulations of the Town of Southold. Dated: (9 l S� lX3 l ��S.'`,�- ` (Signature) P Tint Name)-e-^ ` — (Signature) T (Print Name) Certificate of Compliance CERTIFIED ELECTRICAL INSPECTIONS, INC_. 188 PARK AVENUE AMITYVILLE, NY 11701 P:,(631) 598-5610 _.._....._......-......_............................................... ............._........-.......................................... CERTIFIES THAT Upon the application of Upon premises owned by Anne-Julia Audray Anne-Julia Audray 53930 Main Road/PO Box 593 53930 Main Road/PO Box 593 Southold, NY 11971 Southold, NY 11971 Located at: 53930 Main Road/PO Box 593, - Southold , NY 11971 Application Number#: 20-60707 Certificate#: 20-60707 Electrical License#: - Section: Block: Lot: Building Permit#: BP43662 Described as a Residential occupancy, wherein the premises electrical system consisting of electrical devices and wiring, described below, located in/on the premises at: Renovation of Entire House A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed herein,was conducted in accordance with the requirements of the applicable code/or standard promulgated by the State of New York, Department of State Code Enforcement and Administration, or other authority having jurisdiction,-and found to be in compliance therewith on the 4th day of March 2020 Name QTY, Duplex Receptacle- 15 Amp, 120V 30 Smoke Detector- 15 Amp, 120V 7 Combo Smoke&Carbon Detector- 15 Amp, 120V 3 Exhaust Hood- 15 Amp, 120V 1 Dishwasher Circuit-20 Amp, 120V, 1 GFI Receptacle- 15 Amp, 120 V 6 Dirn,ner=15 Amp 120V 1 Incand. Fixture- 15 Amp, 120V 27 Electrical Inspector:Anthony Giordano �\Ao�u a giiN/ . ;APPROVEDFo� . This certificate is not valid unless raised seal is present.' Certificate of Compliance CERTIFIED ELECTRICAL INSPECTIONS, INC. 188 PARK AVENUE AMITYVILLE, NY 11701 P: (631) 598-5610 ' -...............:......:....................................-......................................................_...................................-......_......_........._....................................................... CERTIFIES THAT Upon the application of Upon premises owned by Anne-Julia Audray. Anne-Julia Audray 53930 Main Road/PO Box 593 53930 Main Road/PO Box 593 Southold, NY 11.971 Southold, NY 11971 Located at: 53930 Main Road/PO Box 593, Southold , NY 11971 Application Number#: 20-60707 Certificate#: 20-60707 Electrical License#: Section: Block: Lot: Building Permit#: BP43662 Name QTY ARC-Fault- 15 Amp, 120V 10 ARC-Fault-20 Amp, 120V 1 Dryer Circuit-30 Amp, 240V 1 Exhaust Fan- 15 Amp, 120V 3 Furnace/Motor(2) Circuit- 15 Amp, 120V 1 Switch- 15 Amp, 120V 23 Electrical Inspector: Anthony Giordano This certificate is not valid uniess raised seal is present. moo - to . Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 Q �o BUILDING DEPARTMENT TOWN OF SOUTHOLD CER_TIFICAT-ION Date: Building Permit No. Owner: (Please print) Plumber: WA lease print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. (Plum ers Signature) ik Sworn to before me this day of��'� , 20a PAIGE M.COSTA NOTARY PUBLIC,STATEOF NEW YORK No.01 C06405502 �,✓ Qualified in Suffolk County �y �c� l� _ Commission Expires March 9,2024 No Public, Count Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: L ' Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from-plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9,1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5.• Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00- Date. 14 Z 2oLg New Construction: Old or Pre-existing Building: OL (check one) Location of Property: S 3 g M A l Pk (���A Sc�V� O I� RV 110311 'N House No. Street Hamlet Owner or Owners of Property: © Uy A M 1`t E L C.. - Suffolk County Tax Map No 1000, Section 61 Block o 4 Lot 10-1. 1 Subdivision sO Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: v (check one) Fee Submitted: $ '1-2 V Applican ign Condon Engineering, P.C. New York State Licensed Professional Engineers 1755 Sigsbee Road 631-298-1986 Mattituck, New York 11952 Fax 631-298-2651 condonengineering.com July 1, 2020 Mr. Mike Verity Chief Building Inspector Southold Town Building Department 53095 Route 25 P.O. Box 1179 Southold, New York 11971 Re: BP#436827-53930 Main Road, Southold Dear Mr. Verity. I visited the building several times during construction and found the footings, framing and strapping to be in accordance with plans. I also inspected the rough plumbing and insulation and found it to be installed in accordance with the New York State Plumbing and Energy Conservation Codes. Based on my inspections it is my professional opinion that the structural, plumbing and insulation work was completed in accordance with the New York State Building Code. If you have any questions, please call me at 631-298-1986. Yours truly, c n N�ondon, P.E. i pE SOUIy�� # TOWN -OF SOUTHOLD BUILDING DEPT. �yco 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ rlULATIOWCAULKING FRAMING /STRAPPING [ AL h &4_ff-tn7'l% [ ] FIREPLACE & CHIMNEY ; [ ] FIRE SAFETY INSPECTION [ ] TIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: I 4v- u 4 i S- S�'VP( UmWncf�� "'o hlc$ vvewtk (.,;Io I CZJ�CW Of V4F,- -Is- Cp 1Telp4f4 xme�� 1eleel � DATE �0 '�D� -INSPECTOR Of 50(¢yO! TOWN OF SOUTHOLD BUILDING DEPT. couff", 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION.2ND _ [ ] I ULATION/CAULKING [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION- [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) ..................................... 'FOUNDATION (2ND) 33 O � -a ROUGH FRAMING& PLUMBING INSULATION PER N.Y; y STATE ENERGY CODE op/ni mv"Kt �r r i ,�✓j Vitf FINAL . t?�T i a ll 000 W" voi pr ADDITIONAL COMMENTS vb o o rn O z ' d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631).7654802' Planning Board approval FAX: (631) 765-9502 /j� J din � Survey Southoldtownny.gov PERMIT NO. �( bU Check Septic Form N.Y.S.D.E.C. c, Trustees C.O.Application Flood Permit Examined 20 Single&=Separate _ Truss Identification Form Storm-Water Assessment Form 2j L Contact: $�nAe--a uVi'ft T10>RA Approved ,20 Mail to: / Disapproved a/c // } Phone: 6 U - 6 18- lc C7 Expiration 120 l Building Inspector RD E���-'� 1� APPLICATION FOR BUILDING PERMIT D APR 1 9 2019 Date K ) 20- INSTRUCTIONS 20INSTRUCTIONS 1V(UST'be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets oT0M0J190qJtA1JWo scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues.a.Certificate of Occupancy, s £,Every building permit shall expire if the work authorized has not commenced within 12 months after the date of i's'suance or has not been completed withm 18-inonths from`such date. If no zoning amendinents"or'otlier regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.,Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings,additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Sidfurre of applica name,if a corporation) X30 4 RV 113 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder nw t Name of owner of premises C)Lk k V iN1A1`d•E LLC--. (As on the tax roll•or latest deed)' If applicant is a co ion, jignAure of duly authorized officer (Name and nikof co e officer Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 5 39 3o t'1 �H RQ A House Number Street Hamlet County Tax Map No. 1000 Section , Block _`, o ', Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy 'D W E L Iib (t– RA ok so m ar- r, b. Intended use and occupancy S E 3. Nature of work(check which applicable): New Building Addition Alteration Repair _Removal Demolition Other Work L9 F'D AT E' S I U C71 V OZ I'LL (Description) 4. Estimated Cost g®CP Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of e fisting structures, if any: Front 1' _Rear 3o Depth 36 **' Height R, Number of Stories 2 _ Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front RearA e-i Deptll, i I Height Number of Stories .� r d 9. Size of lot: Front fe 50 12b F-Rear Depth 10. Date of Purchase 0 1 LA 3o 26 l Name of Former Owner S Lk V QULG� 11. Zone or use district in which premises are situated H 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO Oe, 13. Will lot be re-graded? YES NO_C� Will excess fill be removed from premises? YES NO 14. Names of Owner of premises® � r P( (Address Phone No. 6 4 6-6 7 8 l Name of Architect !:!C"1A. Ca{�(�F��.� Address one No =R4 Name of Contractor Address Phone No. �10&t rLICA. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 4�-1+-�-�1 ll✓ v,-. 17. If elevation at any point-on property is at 10 feet or below,must provide topographical data on survey. I8.,.Are there any covenants and restrictions with;respect to this property? * YES NO * IF YES,'•PROVIDE A COPY. STATE OF NEW YORK)_ St COUNTY OFLL� - O 1 L U •1 tldbemg d ly sworn, deposes and says that(s)he is the applicant "c— (Vine'of indi ' ,' g c ntract) above named, (S)He is the 1" 1• G-M Se R. _ (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this 0 rM day.of j46��)A -9 il Notary'Public • DWYER Signa re of Applicant TARY PUBLIC,STATE OF NEW YORK NO.01 DW6306900 QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30,2 9, SURVEY OF PROPERTY N AT SOUTHOLA OF SUNT SUFFOLK COUNTY , MY ioo0-es-o4-s&s Aram s - atra/sT v.2W7 2887 21 X) 0+10 1000 Z I g \ al got +�� 00- ar7tR71Eo ra /fes SanR9m UMM)dEWODAST CRURW 'top RBST A4ffR M WILE NWWOE CMWMY or NEW roar AREA SOXG SM Fr., a-S W Roser nR MW mat S11[EXCAMW LAK rC P.a 1r�AS v SM' 229 Z ALL nstt�rM 16.n)7B5-So2o Pax(H]q 7E5-1797 $a"GP CW=wm UK WR=V R„w nye SLIW= 123P.a SOx H9H WWW9WTM eARMWAVM 1230 R7A1'ELER STREET SONiN01lA N.Y.1187! 07'-185 i 1 Repair Brick Foundatio 1 \ / 1 \ / \ MASTER / 1 \BEDROOM 1 \ / Kil chen U U Bedoom Y O 2 x 7 FJ 00 X io -, U Replace with New FJ Size nknown 24 OC ci CD 0 Egressable Window X Zo 5.7 SF Clear X 3 2 x 5 4 PSL 3 2 x 5 4 PSL Support N Opening M Support Repair olumns Columns From Above � Brick and Below Down to Foundation rom Above 3 2 x 5 4 PSL Support Foundation 3 2 x 5 4 PSL Sup ort 32x51 PSL � Columns Down to 1st olumns Down t 1st - Floor Framing - (3) 1.75 x 7.25 LVL e/w( ) .5 FP Floor Framing New Op in Support Colut�lns 1 (3 1.75 x 7.2 VL Laundry Equipt. 5_25 x 11.25 PS 3. x 9.5 PSI. O BATHROOM \ / 1 / 1 ew W II Openin Replace with New 1 Studs Screw Ledger Boards Replace Existing Columns wit ew ATHROOM Egressable Window \ New der / Repair Brick Foundatio �„ p g 5.7 SF Clear with 2 Bolts 16 OC "0 Structural Steel Columns Opening New Doo Opening Reframed \ ICLOSET Staggered Re ve Existing tuds As Necessary \ • e ove Wall Studs 0 0 • \N=j (2)2 x 8 Hdr • O \ 6 x 6 Repl 3ce Existing Column with -- --—- -- New Door Opening/ 1 � 6 x 6 -, 4 5 4 1 PSL Support Column U \ / i? U L U Down to Beam in Cellar — M O — — �_ — — _ �O O - 1EXISTING x v m x x ;;t Remove Wall SiA — HIMNEY M N M N 11 Sister 2 x 8 s to Existing Beam 2) 2 x 8 e/w(1) 0.25" FP / o Assure Adequate Support of 5 4 x 5 4 Post Above BEDROOM UOU BED OOM / \ B DROOM coO co 6 x 6 1 Replace with New COLi N M N Egressable Window / Replace with New Repair Brick Foundatio 5.7 SF Clear Replace with New / I Egressable Window Egre sable Window"---*" 1 Opening / 5.7 SF Clear Opening LIVING ROOM 5.7 SF Clear / � � Opening 1 Repair Brick Foundlatio Replace with NeV IReplace with Ne Same Size Windows I e Size Windows FJ Size Unknown PORCH I Replacewith New Same Size Indows Cellar Plan 1st Floor Plan 2 nd Floor Plan Existing Floor Joist Existing Flitch Bea O O � (3) 1 3/4"X 7.25" LVL 5/8"0 Bolts 2" 16" Add Support Under — - - - - - - ® Existing Joist 2° -._J3s4" Replace Existing Column with I (2) 0.5"A36 5 4 x 5 4 PSL Support Colum Steel Flitc � Down to Beam in Cellar �Plate e: B Flitch Beam Detail Scale: 1"= 1'-0" C.3 Plans are prepared b Condon Engineering,P.C. It is a violation of the New York State Education "~ P P Yci "+ Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed ~fa ' q.3 Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Land Surveyor shall affix to the item his/her seal and the notation"Altered by"followed by his/her signature and the date of such alterations,and a specific description of the alteration. Scale: 1/4" = V-0, Condon Engineering, P.C. Parsonage 9 Drawn by : JJC 1755 Sigsbee Road 53930 Main Road Mattituck, New York 11952 Southold, N.Y. S- 1 Date : 6-26-2020 (631) 298-1986 Repair Brick Foundatio f-- (2) 2 x 8 MCQ 1ew Door Opening (0 1> (J, 16"x 51'x 8" Pad I i to a CI�JSET \ n `C`\ J� . .,.,., n DATC:. r, \ 77 Footing—`� I ;° 2 x 6 MCQ FJ 1 X 1 / 5� G� � FI F: /jA765-18 ? J ��(C� FOLIC --� - (2) r-.% 8 MCQ \ MASTER / QFC „',� - `t)i't'tu Ledger Board 1 \BEDROOM r0 �., r, ., .. , :, , 12"Q1 Sonotube 1 'r-- ` t. -•. Footings I \ / 2. RO ;G!, Kil Chen 36' High F ai ings wit U Dining Room v1 '• iNf JL . f ,s 'T O X -� Replace with New p - - 24 OC N Zo U U FJ Size �Jnknown Gp,� Dr rO.I; -`_. L: C.t-' p Egressable Window Q\.P' ,t; iiC�'; `;;r,L.L i'p,`�-T I X 00 m 5.7 SF Clear ass ALLr r ;, S O`.cO 3 z x 5 a PSL Opening 11a �T�, E. Pio i i E4 r0'!:'!?L r= FOR X 3 2 x 5 4 PSL Support X10 YOR Repair Sup port Columns From Above �� ,CaYlO�Ca. D � r; Oil{ Brick and Below Down to r� rr,�P,�i r�LiG�li XPi ER tOt,S. Above e Foundation Foundation $,e 3 2 x 5 4 PSL Support 2 x 5 4 PSL Support 1 1 ge CC`MPL WITH ALL CODES Or Columns Down to 1st olumns Down t 1st 3 z x 5 a PSL lea`) NEVA' YOR t STATE & TOWN CODES Floor Framing - (3) 1.75 x 7.25 LVL e/w( ) 5 FP loor Framing New Op in `Support Columns AS REQUI tED I .75 x 7.25 VL - ent Runt n Tni�ai�o n i t 3.5 x 9.5 PSL 3. x 9.5 PSI ' filA ` ES —— —— — N. ® BATHROOM I • / 1 New W II Openin I Studs 4 FR E ,,•- ,� s/ "' Screw Ledger Boards ew der `f • °� .i �° Repair Brick Foundation- g Replace Existing Columns wit flew BATHROOM \ / a t" 9 A with.1 Bolts 16 OC "Q1 Structural Steel Columns New Doo Opening Reframed �. I ` ' ' ` ' Staggered Re ve Existing tuds As Necessary \ g CLOSET „ice =J t.�l.. '� i a �- -- • e ove Wall Studs O O • `c'E E E �w 1i 11�6p�°� (2)2 x 8 Hdr • O \ a r ° r�r,ri,I ry O \ / -- E15 -- -F F IN 6 x I __ 77Repl ce Existing Column with New D or O enin '- 6 x 6 -, U p 4 5 4 PSL Support Column U \ / U 11- 0 Dow to Beam in Cellar — — AM- — — _ __ �!/ — u,_O — — — (STING x /�\ x d X "v Remove Wall SiA — —— —— M N HIMNEY ce) N / I ch N 11 Sister 2 x 8 s to Existing Beam 2) 2 x 8 e/w(1) 0.25" FP o Assure Adequate Support of / \ 5 a x 5 4 Post Above BEDROOM UOLL UO BED OOM \\ B DROOM co 6 x 6 1 Replace with New rxi N N gressable Window / I Replace with New Repair Brick Foundatio 5.7 SF Clear Replace with New / Egre sable Window"-� 1 Opening Egressable Window / I \ 5.7 SF Clear 1 LIVING ROOM 5.7 SF Clear L NOpen ng Opening / I \ Repair Brick Foundatio I Replace with New Replace with New Replace with Ne IReplace with Ne Same Size Windows Same Size Windows Same Size Windows S a me Size Windows FJ Size �lnknown PORCH Replace ith New Same Size indows I I'st,-Fro- r FraminPlan 2y d- Floor Framing Plan &tfic Floor Framing Plan � � 5S , z � 1x1 MCQ Baluster Existing Floor Joist Existing Flitch Bea Graspable Hand 415 Rail > 1 4'0 < 2"0 \ A P P R O � O (3) 1 3/4"X 7.25" LVL 5/8"0 Bolts a � ih 2" .1611 Add Support Under 7 MCQ = _ _ _ _ = i _ .� Existing Joist 1 2"f— "f— 3Y4" Replace Existing Column with 2)$"0 Galy. dolts (2) 0.5"A36 5 x 44' 5 4 PSL Support Colum Steel Flitc Down to Beam in Cellar Flitch beam Sup ort Details Plate impson ABU66 ZMax Flitch �ea� Detail Scale: 16" . 12"0 Sonotub M Entry Deck Column Footing Detail Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed ?'+•, ..X11` Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing Scale Y"=1'-0" the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Land Surveyor shall affix to the item his/her seal and the notation'Altered by'followed by his/her signature and the date of such alterations,and a specific description of the alteration. Scale: 1/4" = 1'-0' Condon Engineering, P.C. Parsonage g Drawn by : JJC 1755 Sigsbee Road 53930 Main Road S- 1 Mattituck, New York 11952 Southold, N.Y. Date : 4-21-2019 (631) 298-1986 r. Framing Notes: The contractor is to verify all measurements in the field and any discrepancies are to be brought to the attention of the Engineer prior to construction. Wood Framing 1. All lumber is to be No. 2 or better Douglas Fir Larch (N)with the following minimum specifications: Fb = 825 psi Fv= 95 psi Fc perp =625 psi E = 1,600,000 psi 2. All Parallam (PSL) Lumber is to have the following minimum specifications: Fb=2,900 psi Table 3.1 Nailing Schedule(Wood Framed Construction Manual 2015,Page 149) Fv= 290 psi Joint Description Number of Common Nailsl Nail Spacing Fc perp= 750 psi ROOF NAILING E = 2,000,000 psi Rafter to Top Plate(Toe-nailed) 3-8d per rafter 3. 3.All Microllam (LVL) Lumber is to have the following minimum specifications: Ceiling Joist to Top Plate(Toe-nailed) 3-8d per joist Ceiling Joist to Parallel Rafter(Face-nailed) 5-16d each lap Fb=2,600 psi Ceiling Joist Laps Over Partitions(Face-nailed) 5-16d each lap Fv= 285 psi Collar Tie to Rafter(Toe-nailed) 2-10d per tie Fc perp= 750 psi Blocking to Rafter(Toe nailed) 2-8d each end E = 1,900,000 psi Rim Board to Rafter End Nailed 2-16d each end WALL FRAMING Top Plate to Top Plate(Face-nailed) 2-16d(1) per foot 4. All pressure treated lumber is to be MCQ No. 2 or better Southern Yellow Top Plates at Intersections(Face-nailed) 4-16d joists-each side Pine. Stud to Stud(Face-nailed) 2-16d 24"o.c. Header to Header(Face-nailed) 16d 16"o.c.along edges Fb= 975 psi Flo— 90 psi Top or Bottom Plate to Stud(End Nailed) 2-16d per 2x4 stud Fc perp=660 psi E = 1,700,000 psi Bottom Plate to Floor Joist,Band Joist,End joist or Blocking(Face-Nailed) 2-16d (1,2) per foot 5. All beams fabricated with multiple Laminated Veneer Lumber boards are to FLOOR FRAMING be nailed/bolted in accordance with the manufacturer's specifications. Joist to Sill,Top Plate or Girder(Toe-nailed) 4-8d per joist 6. All TJIs are to be installed in accordance with the manufacturer's Bridging to Joist(Toe-nailed) 2-8d each end specifications and shall include squash blocking and web stiffeners at Blocking to Joist(Toe-nailed) 2-8d each end bearing points on girders and other load bearing areas. Blocking to Sill or Top Plate(Toe-nailed) 3-16d each block Ledger Strip to Beam(Face-nailed) 3-16d each joist 7. All straps, connectors, plates, bolts, nails, etc. are to be galvanized or Joist on Ledger to Beam(Toe-nailed) 3-8d per joist Band Joist to Joist(End-nailed) 3-16d per joist stainless steel. Designated connectors, strap etc. on these drawings are - , Band Joist to Sill or Top Plate(Toe-nailed) 2-16d (1) per foot made by Simpson unless indicated otherwise. All connectors, straps etc. are j ROOF SHEATHING to be nailed/bolted in accordance with the manufacturer's specifications. Structural Panels 8d (Detail sheet S-2) 8. All floor sheathing is to be 2%2 inch AC type plywood, tongue and groove, with an APA span rating of 48/24. Floor sheathing shall be glued and screwed to the floor joists (6"O.C. edges and 12"O.C. field ). CEILING SHEATHING 9. All wall sheathing is to be 15/32 inch APA Rated Exposure 1 plywood and Gypsum Wallboard I 5d coolers 7"edge/10"field shall be nailed with 10d common nails 6"O.C. edges and 12"O.C. field. WALL SHEATHING 10. Solid blocking is to be installed every 8' max or mid span of all floor joists Structural Panels 8d 6"edge/12"field with spans exceeding 8'. Gypsum Wallboard 5d coolers 7"edge/10"field 11. Double joists are to be installed below parallel walls. FLOOR SHEATHING 12. Blocking is to be installed at all point load bearing points. Structural Panels 1"or less 8d 6"edge/12"field 13. Walls are to be framed with 2x6 inch studs spaced 16 inches OC unless 1 Nailingrequirements are based on wall sheathing nailed 6"on-center at the panel edge. If wall sheathingIs nailed 3" indicated otherwise. ( ) q g g ' on-center at the panel edge to obtain higher shear capacities,nailing requirements for structural members shall be doubled,or alternate connectors,such as shear plates,shall be used to maintain load path. 14. All bolts nuts and washers are to be hot dipped galvanized. (2)When wall sheathing is continuous over connected members,the tabulated number of nails shall be permitted to be Steel reduced to 1 -16d nail per foot. 1. All steel is to be ASTM Specification A-992-50 2. All steel used in the first floor framing is to be Galvanized in accordance with ASTM Specification ASTM A123 Design Loads: 3. All bolted connections are to be made with A-325 bolts. Roof-Live Load-20 psf 4. Square/rectangular and circular columns are to be ASTM Specification A500. -Dead Load- 15 psf 5. All welded connections are to be done by a certified welder and conform to Attic Dead Load -30 psf AWS and AISC standards. -Dead Load- 15 psf 6. All weld joints are to use E70XX electrodes. 1 st&2nd Floor-Live Load-40 psf - Dead Load- 15 psf 7. Steel is to be prime coated. -Wind Loads- 130 mph-ASCE-7 8. Y2'web stiffeners are to be installed at all point load bearing points and over MWFRS-Method 2 all column supports. 9. All columns are to be bolted to steel girders with Y" bolts and to wood girders with Y2' lag bolts. `' A." 10. All girder splices are to be made above columns. Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Land Surveyor shall affix to the item his/her seal and the notation"Altered b followed by his/her '' ' signature and the date of such alterations,and a specific description of the alteration. Scale: 1/4" = V-0, Condon Engineering, P.C. Parsonage g Drawn by : JJC 1755 Sigsbee Road 53930 Main Road Mattituck, New York 11952 Southold, N.Y. Date : 4-14-2019 (631) 298-1986