Loading...
HomeMy WebLinkAbout45278-Z fv1 �o�guFFQ�CI Town of Southold 10/3/2020 tA P.O.Box 1179 oio "153095 Main Rd � Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41489 Date: 10/3/2020 THIS CERTIFIES that the building AS BUILT ADDITION Location of Property: 2095 Ruth Rd,Mattituck SCTM#: 473889 Sec/Block/Lot: 106.-7-6 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/16/2020 pursuant to which Building Permit No. 45278 dated 10/2/2020 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"pavilion addition to an existing one family dwelling as applied for. The certificate is issued to Diakovasilis,Konstantinos of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED riz lignatureth 7yFFO4� TOWN OF SOUTHOLD gU �y BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 45278 Date: 10/2/2020 Permission is hereby granted to: Diakovasilis, Konstantinos 2095 Ruth Rd Mattituck, NY 11952 To: legalize "as built" pavilion as applied for. Additional certification may be required. At premises located at: 2095 Ruth Rd, Mattituck SCTM # 473889 Sec/Block/Lot# 106.-7-6 Pursuant to application dated 9/16/2020 and approved by the Building Inspector. To expire on 4/3/2022. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $576.00 CO -ADDITION TO DWELLING $50.00 Total: $626.00 Bu1 ding Inspector Form No.6 TOWN OF SOUTHOLD ' ' �V BUILDING DEPARTMENT D t—��--'' D TOWN HALL 765-1802 SEP 2 9 2020 APPLICATION FOR CERTIFICATE OF OCCUPANCY IT �1p This application must be filled in by typewriter or ink and submitted to the Building I,eparttnenY witli&°fottowing: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. New Construction: Old or Pre-existing Building: V (check one) Location of Property: C 4�y House No. Street Hamlet Owner or Owners of Property: `K,`�_Jf/05 . Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ Applicant Signature FIELD-INSPECTION REPORT DATE COA MENTS FOUNDATION(IST) CO -------------------------- FOUNDATION(2ND) r Z- ROUGH FRAMING& y PLUMBING INSULATION PER N.Y. y STATE ENERGY CODE / O s • i FINAL I AD IT'10 -AL COMMENts- rJ 770 id s o U\ z m TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502 Survey Southoldtownny.gov PERMIT NO. 5 Check Septic Form NYSD.EC Trustees C O Application Flood Permit Examined 20 c:2 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved 20 0Mail to-' Cl Disapproved a/c a " f �&LA Phone• C -�•`E iratio�%r'= f' 7 2Y Bui ting pector u S E P 1 G 2020 APPLICATION FOR BUILDING PERMIT Date 20 +J•y, i T �qq,1= INSTRUCTIONS Th[Sdr 11 aC1i011��^ pp M be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections.. /� aC�IVAr— 11Gc1I A (Signature of applicant 6r name,if a corporation) 75 (Mailing address of applicant) State whether applic is owne,lessee,a nt architect,engineer,general contractor,ele rician,plumber or builder !22✓ - � Gl Alzf&Al7S Name of owner of premises As on a tax roll or latest deed) If applicant corporation,signature of duly authorized officer (Name and title of corporate officer) Builders License No. ,572gZJ Plumbers License No. Electricians License No. Other Trade's License No. 1. I,.QCafiqf�nd o hich�ropos�d work will be o House Number Street Hamlet /L County Tax Map No. 1000 Section 106' Block --I Lot Subdivision Filed Map No.Z&ao Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Additio Alteration Repair Removal Demolition Other Work - escription) 4. Estimated Cost d-2 ,1 gOU,UCS Fee F (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front ;�-A r Rear �6 I Depth J/ Height Number of Stories Dimensions of same structure with alterations or additions:Front Rear Depth Height Number of Stories A. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO 13.Will lot be re-graded?YES NO Will excess fill be removed from premises?YES—NO- 14. ESNO14.Names of Owner of premises r Ael Address75 .�1 !'� Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO i *IF YES,PROVIDE A COPY. STATE OF NEW YORK) S: COUNTY( �tl U+ (XrrD being duly sworn,deposes and says that(s)he is the applicant (Name of indrvid 1 sig 3.1rch contract)above named, (S)He fs the r— (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application, all that statements contained in this application are true to the best of his knowledge and belief;and that the�yc�r1S I�ST�IV�VOLI NSKI performed in the manner set forth in the application filed therewith c: I1 NOTARY PUBLIC-STATE OF NEW YORK Sw F re me this No. 01V06105050 day of 0� uallfled in Suffolk County My Commfsston Expifes February 28,2024 NotaryPublic Signa f Applicant To: Town Of Southold - Building Department From: Paraskevi V. Diakovasilis 2095 Ruth Rd. M attituck, NY 11952 Enclosed you will find 4 sets of plans for the roof and post structure. Also the Application for Certificate of Occupancy. Thank you. Paraskevi V. Diakovasilis n su L 2Q r S.C.T.M. NO. DISTRICT. 1000 SECTION: 106 BLOCK: 7 LOT(S):6 VACANT 150' EDGE OF PAVEMENT R IJT CONSTRUCTION H ROAD ENTRANCE WATER MAIN CONC. CURB CATCH BASIN U.P. 71039'20" E 100.00' U.P. EL 7.9 >, m W.V. EL 58.3 T � W.M. 85.00' o 0 \ > U SANITARY.* 9 cv 4 �, EXISTING COVERED + �o OVERHEAD UTILITIES EL 59.4 21- CONC. PORCH ENTRY 27.9' ;'.••BAY�'26.9'. 11 EL 61.1 N•5:5 ' .r.,: ;. 1 STORY :��.:�••:��•'• '.:�:•� (7'7 o ;:. .•: :..•:FRAME #2095•:,' '•.•':: .N LOT 10 1 1, v 60.3'•;:.'._::'..i:.i.:::` LOT 7 EL 59.7 CONC. j ;E4 p DWELLINGS W/PUBLIC WATER DWELLINGS 150' a W/PUBLIC WATER 150 a F PROPOSED UNDERGROUND EL 61.2 E 0.1 UTILITIESTYPICAL DRYWELL CROSS SECTION O I I (CONC. PRECAST COMPONENTS) 0 o PROP. 3 BEDROOM ELEV. 58.9 I 1000 GAL. s.T. I v 0 SIAII FOR^�- BMNO DR BROWNa (1)8'DIAX12'DEEP L.P. > a•SLAB FON TRAFFIC aFARwcWAVY DUTY '0_' APPROVED INLET PIPE f IRON FRAME AND APPROVED OUTLET PIPE _—--- _OL - ANDY LOAM 0.7' - —=Z -1- — - - - -DEC __`ESWRLE - oD -_ - LaN•4•Dtt -_-_ - -- _ covm_ro_GRADE__—ro�ArN a OIL I PRCHED I/e'/r PLAY:91 MEA BROWN PROPOSED4.5' DuS i., ® � 0 0 IQ SM LOAMY SAND 2.3 STAGING AREA IRYY s.3 I3 [] & GRAVEL8'DIAx6'DEEP CONCRETE WASH OUT AREA I `WELL ' 1,� 8'MIN B'MIN .a N IN BED OF PROPOSED DRIVEWAY. 'C N LP EXP. 10'M 10 0 S.T. 0 PALE z a BROWN \0 o i 00 SP MSAND 119.6' c o 50.0' 30.4' & SILT FENCE ALONG - GRAVEL PROPOSED LIMIT FOUNDATION OF DISIURMCE t LOCATION O EL 60.5 14.0' EL 58.9 02-27-20 N 8' IAx4'DEEP , TOP FND EL 60.0 c3:,0 MIN $ WELL CLL EAN FILL ANBD GRAVEL E COVERED STO GE SILT FENCE ROOF OVER CONC 0.6'W 16.2'::a, 15.2 : 5' WIRE FENCE SHED:iN iV w ,8a NPICAL SILT NO WATER '§HEo ^ 0 O'? SCREEN SECTION 17, w ,, EL 59.2 DEC. 8, 2019 EL 58.9 " ' 3.7'N 3'S'N GEOTEXI LE FABRIC _ 5 RE FENCE SUPPORT Posrs K. WOYCHUK LS �7T J —— — wooD OR METAL MON. S 71039'20" VV I 100.001 FLOW DIRECTION DRAINAGE CALCULATIONS: DWELLINGS EXCAVATED AND W/PUBLIC WATER I LOT 17 BACKFlLLED TRENCH A) DWELLING W/COVERED PORCH=1,028 SQ.FT. LOT 16 150' I EXISTING OROUN 1,028 x 0.166=171 Of REQUIRED (1) 8'DIA x V DEEP DRYWELL=177cf PROVIDED low _B) DRIVEWAY=1440 SQ.FT. 1440 x 0.166= 239cf 4 (1) WDIA x 6' DEEP DRYWELL- 265of PROVIDED TMINIMUM NON-CONFORMING FRONT: 40' MIN THE WATER SUPPLY, WELLS, DRYWELLS AND CESSPOOL SIDE: 15' MIN (35' TOTAL) REAR: 50' MIN LOCA77ONS SHOWN ARE FROM FIELD OBSERVATIONS ZONED R-40 REVISED 08-28-20 AND OR DATA OBTAINED FROM OTHERS. AREA: 20,000 SQ.FT. or 0.46 ACRES FND. LOC. 02-27-20 ELEVATION DATUM: NAVD88 ------_------- UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCA77ON LAW. COPIES OF THIS SURVEY MAP NOT BEARING 7HE LAND SURVEYORS EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE 777LE COMPANY, GOVERNMENTAL AGENCY AND LENDING INS77TU77ON LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE. THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE ]THEY ARE NOT INTE'NDE'D TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE ERECTION OF FENCES, ADD177ONAL STRUCTURES OR AND 07HER IMPROVEMENTS. EASEMENTS AND/OR SUBSURFACE STRUETURES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE 77ME OF SURVEY SURVEY OF: LOT 8 CERTIFIED TO: PARASKEVI VOULA DIAKOVASILIS; MAP OF: SUNSET KNOLLS SECTION 2 KONSTANTINOS DIAKOVASILIS; FILED: APRIL 9, 1970 No.5448 SITUATED AT: MATTITUCK TOWN OF: SOUTHOLD KENNETH M WOYCHUK LAND SURVEYING, PLLC SUFFOLK COUNTY, NEW YORK Professional Land Surveying and Design P.O. Box 153 Aquebogue, New York 11931 FILE # 19-177 SCALE: 1"=30' DATE: DEC. 17, 2019 PHONE (631)298-1588 FAX (631) 298-1588 N.Y.S. LISC. NO. 050882 maintaining the records of Robert L Hennessy & Kenneth M. Woychuk PP4PP OVED AS NOTED DATE: d B.P.# 5�2 z O FEE: r BY: Ll NOTIFY J ARTMENT GENERAL CONSTRUCTION NOTES 765-1802B8IAMNTO DED 4' PM FOR THET FOLLOWING INSPECTION& Q 1. All construction shall conform to the 2020 Residential Code NEW YORK STATE. 1. FOUNDATION -FOR POURED CC^&'i' SQUIRED 1BETE as adopted by New York State May 12, 2020, 0 2. ROUGH - FRAMING & PLUMBING W Additional Code Compliance: , 0 5-8d Nails 3. INSULATION 2020 Energy Conservation Construction Code of New York State, the each end 2020 Building Code of New York State; Plumbing code; Fire code; Mechanical code; 4. FINAL - CONSTRUCTION MUST Q Fuel gas code; Existing building code; Property maintenance code. BE COMPLETE FOR C.O. Z ALL CONSTRUCTION SHALL MEET ALL CODES shall supercede the drawings and shall be incorporated into the E z REQUIREMENTS drawings WHETHER they are indicated on the Plans or NOT. THE CODES OF YORK STATE. NOTT RESPONSIBLE FO S 0 2. Cast-in-place concrete shall be air entrained; 5% < 7%total air content by volume and have DESIGN OR CONSTRUCTION ERRORS O an ultimate compressive strength at 28 days of 3000 psi. Except exposed slabs, garage slabs and steps shall be 3500 psi. All work shall be in accordance with chapter 4. COMPLY WITH ALL CODES OF 0 All Concrete shall conform to the latest ACI standards. SIMPSON 2.5A HURRICANE TIE NEW YORK STATE & TOWN COD 3 3. Base design value for visually graded dimensional lumber: Joists, studs Rafters and All RAFTER TO HEADER NTS AS REQUIRED AND CONDITIONS F O F— Framing lumber shall be DOUG-Fir Larch#2 or better, E= 1,600,000 Min. Fb for dimensional lumber= 850 psi. cc '— Wood exposed to the weather shall be Pressure Treated Yellow Southern Pine#2 or better. Sn BOA 3X G "� Including but no limited to: Deck Framing, Posts, Headers, Girders& Ledgers. T TEES 4. ALL EXTERIOR LUMBER Shall be ACQ requiring the following: -._,__N Y--c-- e a.) All Fasteners shall be Hot Dipped Galvanized-ASTM A 153 class D Q cu or stainless steel. J 0 b.) Use Copper flashing Only against ACQ Lumber Sill Plates OCCUPANCY OR 0 c.) All Structural connectors i.e. simpson strong-Tie or USP, etc shall be Hot-Dipped Galvanized or Stainless Steel. TYPICAL ROOF CONSTRUCTION USE IS UNLAWFUL U) � o Metal Roof on 1/2 exterior grade WITHOUT CERTIFICATE Q structural plywood Sheathing, on 2x6 rafters at 16 inches on center. OF OCCUPANCY TYPICAL SOFFIT CONSTRUCTION. o E•- 6" Wood fascia & 6" Wood rake boards. o oo, N •' o•o tf Additional �, w r 1 X 6" FASCIA 1 X 6" FASCIA Certification o= 2.2 ° a �mc? OC�doU'rMay Be required. 8 OEXPOSEDRO3-2X10 HDR WRAP IN 1CEDAR 49 o S RAFTERS � 0 SIMPSONH2 °Ewcg9 15 m aaoo °m." C NC w E, �oo FACE OF EXISTING HOUSE 6 0= ° YLw`o3m- Y3CCc c om� ? a0 ° � Ey °P.T. Em I y IN CEDAR w Zc to 0.-.— QlLnca�icma - C aE m m� c $w W V)(Dar f cuEo. on ASU66 POST BASE AND 4"CONCRETE SLAB PATIO ANCHOR BOLTS 4"CONCRETE SLAB PATIO EXISTING GRADE I I I I I I I I 4 L J L JI TYPICAL PIER( l REAR ELEVATION L J 12" x 36'" BELOW GRADECOAST-NNPLACE TION L J LEFT ELEVATION SCALE: 1 /4" — 1 '-0" CONCRETE FOOTING. 1'-011 SCALE: 1 /4" = 1 '-0" SECTION - A SCALE: 1 /4" = 1 '-0" 0 N 0 o Z N (A � Q tC W N Cl) W 3-2x10 W W U "L------------'------------------------------ _---------f X6 POST WRAP IN 1 ------------------------------------------ --------- CEDARcon 12 DIA" CONCRETE PIER, 36" BELOW GRADE 1 1 • ' ' MINIMUM. 1 1 1 1 4"CONCRETE SLAB PATIO o N i ; w o H 1 1 Q 1 1 1 1 I I l•/� I I I I 11 � 11 V1 I I I I 1 1 a 1 1 1 1 L J L J 1 1 L J L J 1 1 3-2x10 ; ; FRONT ELEVATION --- <C W o Iy>•-------------------------------------------- ---------- 1� 1 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ LINE OF HOUSE FASCIA zi V RIGHT ELEVATION SCALE: 1 /4" = 1 '-0" E" Q EXTERIOR FACE OF EXISTING HOUSE H t SCALE: 1 /4" = 1 '-0" 5 " w 4:1 M 5/z /Zo U � �o � 20'-011 O �/ x •� N rn no PLAN 1IJ F 4W SCALE: 1/4" = 1'-0" ELJ t { TF OF i'Y�`��