Loading...
HomeMy WebLinkAbout44459-Z Town of Southold 7/25/2020 3 P.O.Box 1179 0 o 4 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41281 Date: 7/25/2020 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1050 Waterview Dr, Southold SCTM#: 473889 Sec/Block/Lot: 78.-7-27 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/19/2019 pursuant to which Building Permit No. 44459 dated 11/25/2019 r was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for .which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as applied for. The certificate is issued to Schill,Mark&Woodhull,Amy of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 44459 2/7/2020 PLUMBERS CERTIFICATION DATED Authorized Signature o�S�FEoc�cvTOWN OF SOUTHOLD BUILDING DEPARTMENT y TOWN CLERK'S OFFICE oy • SOUTHOLD, NY dal � Sao BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 44459 Date: 11/25/2019 Permission is hereby granted to: Schill, Mark &Woodhull, Amy 1050 Waterview Southold, NY 11971 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 1050 Waterview Dr, Southold SCTM # 473889 Sec/Block/Lot# 78.-7-27 Pursuant to application dated 11/19/2019 and approved by the Building Inspector. To expire on 5/26/2021. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 Bu i ing Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. November 13, 2019 New Construction: Old or Pre-existing Building: X (check one) Location of Property: 1050 Waterview Drive Southold House No. Street Hamlet Owner or Owners of Property: Mark Schill Suffolk County Tax Map No 1000, Section 78 Block 7 Lot 27 Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: GreenLOgic LLC Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: X (check one) Fee Submitted: $ 50 Appl' ant Signature Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) I,1M of residing at oCjy (Print property owner's-name) (Mailing Address) C�CsyC�� I 1 do hereby authorize GreenLogic LLC (Agent) to apply on my behalf to the Southold Building Department. IO (Owner's Signature) (Date OL vv_S (Print Owner's Name) CONSENT TO INSPECTION MCI L the undersigned, do(es)hereby state: Owner(s)Name(s) That the undersigned(is) (are) the owner(s)of the premises in the Town of Southold, located at 1050 Waterview Drive, Southold, NY 11971 which is shown and designated on the Suffolk County Tax Map as District 1000, Section 78 , Block 7 , Lot 27 That the undersigned(has) (have) filed, or cause to be filed, an application in the Southold Town Building Inspector's Office for the following: Roof mounted solar electric system That the undersigned do(es)hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon, to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws, ordinances,rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections, do(es) so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances,rules or regulations of the Town of Southold. Dated: /o (Si ature)�m l (Print Nae (Signature) (Print Name) Town Hall Annex _ ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 sean.devline-town.Southold.ny.us Southold,NY 11971-0959 COU BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Mark Schill Address: 1050 Waterview Dr city:Southold st: NY zip: 11971 Building Permit#. 44459 section: 78 Block 7 Lot 27 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Green Logic LLC License No: 43858ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Solar X Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Surrey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixture Time Clocks Disconnect 2 Switches 4'LED Exit Fixtures Pump Other Equipment: 16.350kW Roof Mounted PV Solar System w/ 50 SPR-E20-327W-E-AC Panels and Micro Inverters, AC Disconnect, DC Disconnect Notes. Solar Inspector Signature: Date: February 7, 2020 S Devlin-Cert Electrical Compliance Form xls �o�a04 SOUI/Yo� - t 4 ,5 'V 5 V W,,,t,, nc, -Da, , # # TOWWOF SOUTHOLD BUILDING DEPT. 765-1802 : IN-SPECTION- I FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL<arL.A4Z, [ ] CODE VIOLATION [ ] PRE C/O REMARKS: cvA DATE 'Z-J7, [SO INSPECTOR A M E S J. S TOUT .A R C H I T E C T & Assoc . 2 G REG L ANE E AST NORTHPORT N. Y. 631 - 8 58 9388 Post Installation Letter December 10, 2019 RE: Schill Residence 1050 Waterview Drive Southold, NY 11971 To Whom It May Concern: This letter is to confirm that as of December 10, 2019 I, James J Stout, NYS license 021633 have personally inspected the placement and installation of the roof top solar panels at 1050 Waterview Drive, Southold, NY. The solar panels have been installed as per manufacturer's guidelines and specifications. The racking system design and installation complies with the 2017 NYSRC and 2017 NYSUCS building code and provisions of ASCE 7-10.The installation was done as per plan. Thank you for your cooperation in this matter. James J. Stout Architect r f EB - 5 2020 02 633 OQ� TF OF NO y FIELD INSPECTION REPORT DATE COMMENTS b FOUNDATION(1ST) y ------------------------------------ C FOUNDATION (2ND) z o _ y 1 ROUGH FRAMING& PLUMBING ®V E v INSULATION PER N.Y. � STATE ENERGY CODE FINAL ADDITIONAL COMMENTS Z H 10 z y x d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? 1 OWN'HALL SOUTHOLD,NY 11971 Board of Health TEL: (631) 765-1802 4 sets of Building Plans FAX: (631) 765-9502 Planning Board approval Southoldtownny.gov PERMIT NO. survey Check Septic Fonn N.Y.S.D.E.C. �j Trustees •� � `� ,20 C.O.Application Examined Flood Permit — Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved ,20 Mail to: GreenLogic LLC Disapproved a/c 97 North Sea Road, Southampton, NY Phone: 631-771-5152 Expiration 20 Building pector :APPLICATION FOR BUILDING PERMIT • t , t N0\ 8 2019 Date November 13 20 19 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b.Plot plan shoaling location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. GreenLogic LLC (Signature of applicant or name,if a corporation) 97 North Sea Road, Southampton, NY 11968 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Contractor Name of owner of premises Mark Schill (As on the tax roll or latest deed) If applicant is a corporation, si Iture of duly authorized officer Nesim Albukrek, President / (Name and title of corporatefficer) Builders License No. 40227-H Plumbers License No. N/A Electricians License No. 43858-M Other Trade's License No. N/A 1. Location of land on which proposed work will be done: 1050 Waterview Drive Southold House Number Street Hamlet County Tax Map No. 1000 Section 78 Block 7 Lot 27 Y Subdivision Filed Map No. Lot t , 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single family dwelling b. Intended use and occupancy Single family dwelling 3. Nature of work(check which applicable):New Building Addition AlterationRe air Removal Demolition Other Work_ Roof mounted solar electric system 4. Estimated Cost $51,044 Fee $200 (Description) 5. If dwelling, number of dwellingunits (To be paid on filing this application) Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase 2/2000 Name of Former Owner Anderson 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO X 13. Will lot be re-graded?YES NO X Will excess fill be removed from premises?YES NO X 14. Names of Owner ofremises Mark Schill 1050 Waterview Dr P Address Southold, NY 11971 Phone No. 516-924-4606 Name of Architect James J. Stout Address 2 Greg Ln E. Northport Phone No 631-858-9388 Name of Contractor GreenLogic LLC Address97 North Sea Road Phone No. 631-771-5152 out h ampton, 68 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO x * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO x * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO x * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk Nesim Albukrek being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn_to before me th*i� 1 day of 0%y r 20—La- (11d-Lc 0Lt1-d-Lc itr RBARA A CAS CIOTTA Notary Public Notary Public-State Mo.01-CA4894969 ature of Applicant euslified in Suffolk Cu ty Commission Exp Scott A. Russell 10'Su Ir ST0IKMWATIEIK SUPERVISOR � AV GEMEN T SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 ' Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) _ ____. -_. .._ __. _ _-_ __ _. _ - _____. DOF-5 'I HIS PROJECT [INVOLVE ANY OF THE l+i"�I.l[OWIT�G j (CHECK ALL"rHAT APPLY) i I Yes No ®Q A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ®� B. Excavation or f filing involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑ x0 C. Site preparation on slopes-which exceed 10 feet vertical rise toIt � 100 feet of horizontal distance. �! ®E] D: Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. El E, Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. ❑E] F. Installation of new or resurfaced impervious surfaces of 1,000 square ; feet or more, unless prior approval of a Storrnwater Management 3 Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP'. Complete the Applicant,section below with your Name, Signature,Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Pian and a completed Check List Form to the Building Department with your Building Permit Application. S.C.T. I. 1000 tate. APPLICANT- tPropertq Owner.De.,)-i Professional,Agent,Contractor,Oilier} DLtrtot NAME: 78 7 27 11/13/2019GreenLoaO (Nesm Albukrek Section Block Lot etmntwt -4x€ q '!'***VOR DEPARTMENT ()1tiLY Contact information 631-771-5152 ' I Reviewed By- I I ! t Date_ Pt•ot�erty Address 1 Location of Construction Work-Work- Ij — — — — — — — — — _ — — — — — 'I ;I Approved foi-proccssing�Bulldin;Pernxt. J 1050 Waterview Drive [ Stormwater Management Control Plan Not Required. Southold, NY 11971 [ - - - - - - - - - - - - - - - - - I Stormwater Management Control Plan is Required. , ® (Forward to Engineering Department for Review.) FORM * SMCP-TOS M,kY 2014 BUILDING DEPARTMENT-Electrical Inspector ��. TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX(631) 765-9502 ; roger.,richerttown.southold.ny:Lis APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Barbara Casciotta Date: 11/13/19 Company Name: GreenLogic LLC Name: Robert Skypala License No.: 43858-ME entail: Barbara@Greenlogic.com Address: 97 North Sea Road, Southampton, NY 11968 Phone No.,, 631-771-5152 JOB SITE INFORMATION: (Ali Information Required) Name: Mark Schill Address: 1050 Waterview Drive, Southold Cross Street: Phone No.: 516-924-4606 _ - Bldg.Permit#: email: Tax Map District: 1000 Section: 78 Block: 7 Lot,- . 27 BRIEF DESCRIPTION OF WORK(Please Print Clearly) Roof mounted solar electric system 16 350kW (50) SunPower SPR-E20-327-E-AC panels with micro inverters Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: - A #Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect-Service Reconnected -Underground - Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y- N - Additional Informatiori - PAYMENT DUE WITH APPLICATION 82-Request for Inspection FormAs 11 DATE(MM/DD/YYYY) ;acov CERTIFICATE OF LIABILITY INSURANCE �---'` Fol/3112019 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Brookhaven Agency,Inc. PHONE 631 941-4113 Fax 631 941-4405 128 Old Town Road,Suite C E-MAIL . CustomerService@ brookhavena enc .com P.O.BOX 850 INSURERS AFFORDING COVERAGE NAIC# East Setauket NY 11733 INSURER A. Southwest Marine&General Insurance Co. INSURED INSURER B: Merchants Preferred Insurance Co. GreenLogic,LLC INSURER c: First Rehab Life Insurance Co. 97 North Sea Rd,Suite 3 INSURER D- National Liability&Fire Insurance Co. Southampton NY 11968 INSURER E: AGCS Marine Insurance Co. INSURER F.- COVERAGES :COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS rA TYPE OF INSURANCE ADDL SUER POLICY NUMBER POLICY EFF POLICY EXP MIMIDDIYYYYi LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 CLAIMS-MADE X❑OCCUR DAMAGE TO RENTED $100,000 X Contractual Liability X X GL201900012922 01/3112019 01131/2020 MED EXP(Any one erson $5 000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE s2,000,000 POLICY a]PRO- F1 LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1000000 (Ea arxndent) B X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED AUTOS ONLY AUTOS X X CAP1043565 08M1/2018 08/1112019 BODILY INJURY(Per accident) $ X HIRED �( NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $1,000,000 A EXCESS LIAR CLAIMS-MADE X X UM201900007751 01/31/2019 01131/2020 AGGREGATE $1,000,000 DED I I RETENTION O F $ WORKERS COMPENSATIONX PER OTH- AND EMPLOYERS'LIABILITY ANY D OFFICER/MEMBER EXCLUDED9 ECUTIVE Y/❑N N/A V9WC857891 0611512018 06/15/2019 E L.EACH ACCIDENT $1,000,000 (Mandatory in NH) E L DISEASE-EA EMPLOYEE 1,000,000 If yes,describe under DESCRIPTION OF OPER TIONS below E L DISEASE-POLICY LIMIT $1,000,000 C NYS Disability D251202 04111/18 04/11/19 Statutory Limits E Installation Floater/Property SML93076366 4/15118 4/15/19 $250,000 $1000 Ded DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached H more space is required) Certificate holder is also named as Additional Insured. CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <> @ 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD 1 rr Suffolk County Executive's Office of Consumer Affairs ......�/ D • 12/10/2007 • 43858-AM � �- / I' SUFFOLK COUNTYT c` l Mr Elc ast r r a License r ., This is to certify that ROBERT J SKYPALA doing business as GREENLOGIC LLC 1having given satisfactory evidence of is hereby licensed as MASTER ELECTRICIAN in accordance (\ with and subject to the provisions of applicable laws,rules and regulations of the Countyof Suffolk, of 1 Additional Businesses NOT VALID WITHOUT CONSUMERDEPARTMENTAL SEAL ANDACURRENT II)CAR! Director r , r -- �,� -- tom, ''�f 1. �L. -• ..i— �r —1 '�. :�.\ — r �T �� �. - r 'i •,\, .�.-�o�;� v��_; .����1 r�;. .,1�, ,3Y,F. •�q ��: , ;$�` �,<,' ,.`,- fil`..�"s'J'��•- ,-(t`��F 1. M ........... ........ . M -t1f. Suffolk County Executive-s 0 ce of Consumer Affairs VETERANS MEMORIAL HIGHWAY HAUPPAUGE,NEWYORK 11788 DATE ISSUED: 5/25/2006 No. 40227-H SUFFOLK COUNTY Home Improvement Contractor License .......... This is to certifv that MARC A CLEAN N doing business as GREEN LOGIC LLC having furnished the requirements set forth in accordance with and subject to the provisions of applicable laws,rules and regulations of the County of Suffolk,State of New York is hereby licensed to conduct business as a HOMEy. IMPROVEMENT CONTRACTOR,in the County of Suffolk. Additional Businesses <Z NOT VALID WITHOUT D)EPARTMENTAL SEAL AND A CURRENT CONSUNIEk AFFAIRS ....... ID CARD Director N7 A —~' Y�RI{ Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Shard 1a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured 631-771-5152 Greenlogic LLC 97 North Sea Road Suite 3 1c.NYS Unemployment Insurance Employer Registration Number of Southampton NY 11968 Insured Work Location of Insured(Only required if coverage is specificatfyGmr?ed to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,10-a Wrap-Up Potrcy) Number 203801104 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the'Certiflcate Holder) National Liability&Fire Ins Co Town of Souihold 3b.Policy Number of Entity Listed in Box"1 a" Building dept,53095 Route 25 VgWCO23041 Southold NY 11971 3c.Policy effective period 06/15/2019 to 06115/2020 3d.The Proprietor,Partners or Executive Officers are included.(Only check box if all partnerstoflicers`Included) ' [X� all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3"insures the,business referenced above in box 1a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be•listed under 1LQJR-3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box`2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or'within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from,the coverage indicated.on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance.carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while:the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,if the business.continues to be named on a permit,license or contract issued by a certificate holder,the business must`provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Nicholas Zulkofske (Print name 1� enzed representative or licensed agent or insurance carrier) Approved by tJ IJ (Si ature) (Date) Title:Authorized Agent Telephone Number of authorized representative or licensed agent of insurance carrier: 631-941-4113 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-106.2._tnsurance brokers are NQ1 authorized to issue it. C485.2(9-17) www.wcb.ny.gov . GREENL®GIC° ENERGY November 13, 2019 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Please find attached a building permit application on behalf of the Mark Schill who has engaged us to install a roof mounted solar photovoltaic(PV) electric system located at 1050 Waterview Drive, Southold, NY. In connection with this application, please find attached: • Building Permit application • Owner Authorization • Consent to Inspection • A Storm Water Assessment Run-off Form • Certificate of Occupancy Application • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • GreenLogic Suffolk County Home Improvement License - NOV 1 8 2019 • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License LL • Check for$200 ($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, J3ava ma emciofta Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 ext. 117 GREENLOGIC LLC m www.GreenLogic.com Tel: 631 771 5152 Fax. 631 771 5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S. Service Rd , #106 Southampton, NY 11968 Rosyln Heights, NY 11577 GREENLOGIC° ENERGY January 31, 2020 The Town of Southold Building Department 54375 Route 25 ; P.O. Box 1179 - - "L_'s Southold, NY 11971 _a FEB - 5 2020 Re: Building Permit No. 44459 Mark Schill 1050 Waterview Drive, Southold To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced address. Can you please close the building permit and send the Certificate of Occupancy? Please let me know if you have any questions about the installation. Sincerely, 33aJaw exociatta Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 GREENLOGIC LLC a www.GreenLogic.com Tel. 631 771.5152 Fax: 631 771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S Service Rd ,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 i I N SURVEY OF PROPERTY -T AT BA YVIEW TOWN OF SOUTHOLD SUFFOLKO COUNTY Y, N. Y, 1000-78-07-27 s SCALE.• s NOVEMBER 16, 2011 ��e 1Qp• s 9y P� 18 ?6,ir 10 llp •o.k, �lg.P 2y i Nllk-s y yam Q o+ OF NEW lkl- FLOOD ZONE FROM( FIRM MAP NUMBER 36103CO166H L;,,\,0g�3a� SEPTEMBER 25, 12OD9 N. Y.S. LIC. NO. 49618 ANY ALTERA77ON ORI AD01770N TO THIS SURVEY 1S A VIOLATION 6ECONIC URVEYORS, P.C. OF SEC7701V•72090F THE NEW'YORK STA 7E• EDUCATION LAW. 631 765-5020 FAX 631 765-1797 EXCEPT AS PER SECTION, 7209–SUBDIVISION 2-'ALL CER77FICA77ONS HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF P.O. BOX 909 AREA=14,893 SQ. FT., SAID MAP OR COPIES BEAR 77-1E IMPRESSED SEAL OF THE SURVEYOR 1230 TRA VELER STREET {� WHOSE SIGNATURE APP44RS HEREON. O5—�6c7 SOUTHOLD, N. Y. 11971 � � 1 111 111 fill J { A M E S J. S T O U T S R C II I T E C T & Assoc. 2- GREG LANE EAST N ORTHPORT N. Y. 6 31 — 8 58 9388 COMPLY WITH ALL CODES OF Letter of Certification NEW YORK STATE & TOWN CODE:. AS REQUIRED AND CONDITIONS O� October 31, 2019 VVIViLLM Schill Residence SGFTH-077TGWWN—PrAf 6 D 1050 Waterview Drive SebI � TEES Southold, NY 11971 -�-- OCCUPANCY ®R To Whom It May Concern: USE IS UNC I, James J. Stout, registered architect NYS license number 021633 wok�..► MQJTCERTIFICATE AFUL submit the following. I have inspected and analyzed the roof structure a� mentioned address and have determined the structure and the panelIA be adequate to support the new additional load imposed by the proposed solar�panneT PANCY system and complies with the 130-mph wind design load as 2017 New York State Uniform Code (2017 NYSUC), 2017 New York State Residential Code (2017 NYSRC) = (2015 International Residential Code (2015 IRC) (2nd Printing) and 2017 New York State Uniform Code Supplement(2017 NYSUCS) as well the Long Island Unified Solar Permit Initiative (LIUSPI) and the 2014 National Electric Code NFPA 70/ 2014 National Electric Code, and the ASCE 7-10. The existing 2"x 8" @ 16"o.c.and the 2"x 6" @ 16"o.c. roof rafters will provide the required support. ELECTRICAL INSPECTION REQUIRED Thank you for your understanding in this matter James J. Stout APPROVED AS NOTED DATE: f B.P.# S FEE: 140 BY: ,��F� AR NOTIFY BUILDING DEPARTMEN AT �\c �ti5 � STs` 765-1802 8 AM TO 4 PM FOR THE 41� FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCPETE 2. ROUGH - FRAMING & PLUMBING S o 3. INSULATION -9jc� 0216.3 yOQ 4. FINAL - CONSTRUCTION MUST OF NE`N BE COMPLETE FOR C 0. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. ` R E LO M"' ENERGY GreenLogic,LLC Approved Schiff,Mark 1050 Waterview Drive Southold,NY 11971 Surface#A: Total System Size:16.350kW Array Size.3.270kW 1 circuit of 10 on a 20A breaker Azimuth:123° Pitch:18° Monitoring System: Z------------ --\ SunPower Panei/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel.61.39"X 41.18" x x x x Array:17'4 7/8"X 10'3 1/2" vs.......7V�------7V Surface:19'11"X 15' V [7 Magic#:Invisimount Legend: ® 10 SunPower 327W Panels SunPower Invisimount Rail 1 � ® 18 Quick Mount E Lag x x x x 8 2x6"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: ��keD ASC IZ i T 21 35 NE'No Drawn By:MA Drawing#1 of 11 Date:10/31/2019 REV:A Drawing Scale:1/4"=1.0' ENERGY GreenLogic,LLC Approved Schill,Mark 1050 Waterview Drive Southold,NY 11971 Surface#A: Total System Size:16.350kW Array Size:3.270kW 1 circuit of 10 on a 20A breaker Azimuth:123° Pitch:18° Monitoring System: 2 �{ SunPower LI Panei/Array Specifications, Panel:SPR-E20-327-E-AC Racking.SunPower Invisimount Panel.61.39"X 41.18" Array:17'4 7/8"X 10'3 1/2" Surface:19'11"X 15' Magic#:Invisimount Legend: ® 10 SunPower 327W Panels ® SunPower Invisimount Rail I a 18 Quick Mount E Lag 8 2x6"Douglas Fir Rafter 16"O.C. Notes: NVK \�O Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System-3.5psf Engineer/Architect Seal• / PSDARC �C , n� � 6 7 ,21 3� Off' Drawn By:MA Drawing#2 of 11 Date:10/31/2019 REV:A Drawing Scale* 1/4"=1.0' E LOGOC= ENERGY GreenLogic,LLC Approved Schill,Mark 1050 Waterview Drive Southold,NY 11971 Surface#A: Total System Size:16.350kW Array Size:3.270kW 1 circuit of 10 on a 20A breaker Azimuth:123° Pitch:18° Monitoring System: SunPower Fanei/Array Specifications: Panel:SPR-E20-327-E-AC 1 Racking:SunPower Invisimount Panel:61.39"X 41.18" Array.17'4 7/8"X 10'3 1/2" Surface:19'11"X 15' W Ny NV Magic#:Invisimount Legend: LZ ® 10 SunPower 327W Panels ® SunPower Invisimount Rail 1 ® iS Quick Mount E Lag B 24"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 xy Ny \V Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System-3.5psf Engineer/Architect Seal: QED ARC / C?�� c' J r A i >k i 2 i 33 Drawn By:MA Drawing#3 of 11 Date:10/31/2019 REV:A Drawing Scale:1/4"=1.0' ENERGY GreenLogic,LLC Approved Schill,Mark 1050 Waterview Drive Southold,NY 11971 Surface#8: Total System Size:16.350kW Array Size:8.829kW 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker Azimuth.123° Pitch-11° Monitoring System: SunPower i7, Panel/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" x x x Array:31'1/8"X 18'115/8" Surface:35'9"X 22' Magic#:Invisimount Legend: 27 SunPower 327W Panels ® SunPower Invisimount Rail x x x x x M ® 48 Quick Mount E Lag H 2x6"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 ;r Height above Roof Surface:4" Materials Used:Quick Mount,SunPower x x x X x Added Roof load of PV System:3.5psf Engineer/Architect Seal:7 7 N N likED ARC C1�5 A Drawn By:MA Drawing#4 of 11 Date:10/31/2019 REV:A Drawing Scale 3/16"=1.0' G"',C GREENLOORCO, ENERGY GreenLogic,LLC Approved Schtll,Mark 1050 Waterview Drive Southold,NY 11971 Surface#.g: Total System Size:16.350kW Array Size,8.829kW 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker Azimuth:123° L-APitch•11° Monitoring System: Z SunPower i Panel/Array Specifications: Panel-SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array.31'1/8"X 18'11518" Surface:35'9"X 22' Magic#•Invisimount Legend: ® 27 SunPower 327W Panels SunPowerInvisimount Rai! ® 48 Quick Mount E Lag 8 8 2x6"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: i �kED ARc K A 9 1 T� �1 334y®� 4� Drawn By:MA Drawing#5 of 11 Date:10/31/2019 REV:A Drawing Scale-3/16"=1.0' �j'-,>GREENLC(WCO- ENERGY GreenLogic,LLC Approved Schiii,Mark 1050 Waterview Drive Southold,NY 11971 Surface#13• Total System Size:16.350kW Array Size:8.829kW 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker Azimuth:123° Pitch:11° 2 Monitoring System: �` SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" 3 2 Array:31'1/8"X 18'11 5/8" Surface:35'9"X 22' Magic#•Invisimount Legend: (� ® 27 SunPower 327W Panels SunPower Invisimount Rail 3 4 ® 48 Quick Mount E Lag 8 B 2x6"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface*4" 4 Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf AZAZ Engineer/Architect Seal: ED ARC 21 Drawn By:MA Drawing#6 of 11 Date:10/31/2019 REV:A Drawing Scale-3/16"=1.0' &GREENLOOCe- -C - EINERGY GreenLogic,LLC Approved Schiff,Mark 1050 Watenriew Drive Southold,NY 11971 Surface#C: Total System Size:16.350kW Array Size:4.251 kW 1 circuit of 7 on a 20A breaker 1 circuit of 6 on a 20A breaker Azimuth:213° Pitch:21' N— Panei/Array Monitoring System•SunPower Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:24'4 3/4"X 10'3 1/2" Surface:35'4"X 13' x XIX x x x x Magic#:Invisimount Legend: N/ Z ® 13 SunPower 327W Panels ® SunPower Invisimount Rail 97 ® 22 Quick Mount E Lag B B 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used.Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: RSD 'SRC n� � 1 r 21 Drawn By MA Drawing#7 of 11 Date:10/31/2019 REV.A Drawing Scale-3/16"=1.0' ENERGY GreenLogic,LLC Approved Schiii,Mark 1050 Waterview Drive Southold,NY 11971 Surface#C: Total System Size:16.350kW Array Size:4.251 kW 1 circuit of 7 on a 20A breaker 1 circuit of 6 on a 20A breaker Azimuth:213° Pitch:21' A` Monitoring System. SunPower i PaneUFirray SpeciiicaHor�s: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array-24'4 3/4"X 10'3 1/2" Surface:35'4"X 13' AMagic#:Invisimount Legend: ® 13 SunPower 327W Panels IF SunPower Invisimount Rail rw 22 Quick Mount E Lag 8 B 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers.1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System,3.5psf Engineer/Architect Seal: ED ARC c, J. T p s Or J 21 33 y0� c ��•N Drawn By:MA Drawing#8 of 11 Date:10/31/2019 1 REV:A Drawing Scale:3/16"=1.0' ENERGY GreenLogic,LLC Approved Schill,Mark 1050 Waterview Drive Southold,NY 11971 Surface#C: Total System Size: 16.350kW Array Size:4.251 kW 1 circuit of 7 on a 20A breaker 1 circuit of 6 on a 20A breaker Azimuth.213° Pitch:21' A, Monitoring System: \' SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:24'4 3/4"X 10'3 1/2" 5 Surface:35'4"X 13' Magic#:Invisimount Legend: ® 13 SunPower 327W Panels ® SunPower Invisimount Rail ® 22 Quick Mount E Lag 6 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: �cIkE® 'SRC A p Ar r 21 NE'$ Drawn By:MA DraHnng#9 of 11 Date:10/31/2019 REV.A DraWng Scale:3/16"=1.0' No Vent Pipes Will Be Covered By The solar ArrayEE LOO29C®' LEGEND. `Mr` ENERGY AR -Access roof per R202 definitions RAP -Roof access point-to be away from RWV -Roof with valley, GreenLogfq LLC Approved overhead obstructions,doors, 18'minimum from valley Schill,Mark windows,decks,fences,landscaping 1050 Watenriew Drive GA -Ground access area per R324.7.3 width AP -Access Pathway,36•minimum SVO -Smoke vent operation per Southold,NY 11971 to be same as AP as measured'at eave width per R324 7.4 and R324.7.5 R324.7.7.18'minimum from ridge Total System Size 16.350k"l 1 circuit of 10 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 7 on a 20A breaker 1 circuit of 6 on a 20A breaker Azimuth:123* Monitoring System: RAP SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC G Fr-:7A- Racking:SunPower Invisimount Panel:61.39"X 41.18" 78,;V Array:66'2"X 34' Surface:68'8"X 51'3" API IAP Magic#:Invisimount ! IMeter Legend: I 1 I o I 50 SunPower 327W Panels —SV(,F—— ———————-SVO——————-- SunPower Invisimount Rad S O s O S O 88 Quick Mount E Lag I I 8 8 2x6"Douglas Fir Rafter 16"O.C. I I B 2x8°Douglas Fir Rafter 16"O.C. I Notes: INumber of Roof Layers:1 I Height above Roof Surface:4" I Materials Used.Quick Mount,SunPower O 10 SunPower Added Roof load of PV System:3.5psf I I 327W Panels Engineer/Architect Seal: I I 27 SunPower BRED ARC 327W Panels C, J. T L_b_ �� O� Q C7 . a A � 13 SunPower RAP i 327W Panels P 21 33 -� Nt"a- Drawn By:MA Drawing#10 of 11 Date:10/31/2019 REV:A Drawing Scale- 1/16"=1.0' 'C,PGREENLOURC"I —� ENERGY GreenLogic,LLC Approved Schiff,Mark 1050 Waterview Drive ___ ._._ _ _.._- _______ ____ ___ .__ ___... .._. __ ... __f _ . i. _._ ;_ __-. ____ _ __... { -• i - - Southold,NY 11971 KBMT RkWr t Total System Size 16.350k:N 1 circuit of 10 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker 1 circuit of 9 on a 20A breaker --- --------- ----- - --' --- - 1 circuit of 7 on a 20A breaker 1 circuit of 6 on a 20A breaker -- - - i Azimuth:123° h(bbsial UAQv- MB Monitoring System: i { i SunPower Panel/Array Specifications, ---__—. Panel:SPR-E20-327-E-AC CastA Lrdnim t roElak ElaikAltm_t�nFlashi 8S # t'g 1A� rg � r Racking:SunPower Invisimount 516'X7/8' irgPltg 88 } Panel 61.39"X41.18" Array:66'2"X 34' t �� s'I bC-F E�L�S[7E1N 88 i Surface:68'8"X 51'3" Magic#.Invisimount Legend: 7Fj r SunPower SunPower 327W Panels SunPower Invisimount Rail j i r ® 88 Quick Mount E Lag 2x6"Douglas Fir Rafter 16"O.C. g 2x8"Douglas Fir Rafter 16"O C , i Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: ��vkED ARCIZ �-I5 -, ]. y 4Z A + 1r r � � 1 3`6 O� Drawn By:MA I Drawing#11 of 11 Date:10/31/2019 REV:A Drawing Scale: 1/16"=1.0' „, y.. __ .., - -. '_.. •.. ., �'>tii SPY�;rb as a.,u s ,..:Wim. � .. ,, •ti: • o • q Sirup e-and Fast Installation Ir,e�rle ated module-lo-rail brounc ng .: `` RI ��Z Pre-assembled mid and e.rd damps � �s r ti Lw ..at,ng mid clamp for easy placement Aff i Mid clamp vvicth facilitates consistent,even �a modu e::sparing Simple,p_e grilled rail s ili;re -:.. ,• '1703 Listen int�;;ratc�d,.,rc,un” 7n Flexible Design Addresses:"nearly all slope'_" res deni a!roofs Design it I ndscape aria po tr i. f', is jai le easy u 0stacie marager ent Customer-Preferred Aesthetics �. 'rcdule and#^ mounting aesthetics Best it crass system:-aesthetics Elegant Simplicity Premium, ow profile design Back anodized components SunPower InvisiMountTm is a SunPower-designed i-i dder n,d darrips and end camps rail-based mounting system.The InvisiMount system and capped,flusn rais addresses residential: sloped roofs and combines faster Part of Superior System installation time, design flexibility, and superior aesthetics B11ilt for use with SunPov.er DC and AC me ales The InvisiMount product was specifically envisioned and BBs, in da s syster:re aDility and aestheuc> cmbire.,,t�Sur;Fc� er= od,;iesar,r engineered to pair with SunPower modules. The resulting monitoring app system-level approach will amplify the aesthetic and installation benefits for both homeowners and installers, s^ v � sunpower.com s F Module'*i:"vi c!Clarnp arid Rai Module*i End Clamp and Ra.l 111 ' Mid C amp find Clamn rail K Ra;l Splice Grous,d Luh,Assembly End Cap Ternoerature -40°C to 90°C(-40°F to 194`F) ComponentMaterial v'e gbt .._...................._........ _. ......................----...._.................... ..................... ....._........._... __............_._......................... 3` ----....._ .................—.—..- —._..............._................... —...__—_�......— Max .oao(L RFD) J00 Pa upluplift1... - _ 6000 r a dowrforre M!o Clamp Black oxi e staln!ess steel AISI 304 63 g,7 0�) _ ....._.... . _....................... ........_.................. .............................-................. .......... ... ..._. End Clamp Back ar,odlzed alumrnt:m alloy 6063 T6! 110 g(3 88 oz) Rad Black anoidizr:ci alumni,m alloy 6005 Tr,( 830 g/m(9 ovft) Rad Splice Aluminum alloy 6005 T4 830 g/m(9 oz/ft) 25-year product warrant Warrartles Grouro Lug 304 stainless I Assembly (A2-70 belt,t!rn-prated opoer t !ug) j 106 5 ghr:(3 75 car year firvsh:.ananty _...................._...__.._....._.................-i - —....--.........--- — End Carr Brack acetal(POM)copolymer 10 4 g(0 7 0.) ........_......._.........__.._.....__.... ——.... .... —_._.—...-- ..__�.. ..-- -- UL 2703 Listed Cea!ficatiors Class A Fire Rated Compasuon Sh.ngle I:after Attachment Cumpos,tlon Shingle Roof Dec,tlr?g Attachment ! ApI!caUJn p Cursed and Flat Tse Roof Attacrtmenc Urnversal Interface for Other Roof Attachments Refer to roof attachment har dA'ar e manufactt rens documentation ''.loo.jle trame that ms(orrlpaiible w,ch tt+e;lrw:iNllourit system..equii ed for h:wawa!e!nteroporabtlity :;7.Ot 5 S!.inPower:r,!peration All Rights Reser ed SUNPOWER,the SUNPOW-R logo.anis iNYISI OUNT ae traa maks or registered t tidemarks at:,^Pov er Corpurat nn A::othe,:,ademarks are tf.e prope,ty al:r+eir resFecl.!ve owne; SUrtpewet;.0rn Specincabons ncluded!n th s data,heet are subject to change wnho!at not,ra Document#509506 RevC . S U N P ' WE R"� SunftwerO E-Series: E20-327 I E19-320 \�J SunPower Residential AC Module Built specifically for use with the SunPower Equinox""system,the only fully integrated solution designed,engineered,and warranted by one manufacturer, '.. Maximum Power. Minimalist Design. . wig Affs &a industry-leading efficiency means more power and savings SON-C per available space With fewer modules required and hidden microinvertei s: less is truly more LC'r�, Highest Lifetime Energy and Savings. Designed to deliver 6045 more energy over 25 years in real-world conditions lime partial shade and high temperatures` 1 boli 3 140% Fundamentally Different. a And Better. Up to T 40 " ° more c 4 lifetime d soy energy d Conventional Module Ln N c The SunPower,'MaxeonOSolar Cell Years or operation • ErlGriie.:r'li�l}esu.-•"��:,ency rrocu.es a ur:ail Best Reliability. Best Warranty. U .mat. 1_a ,: a..i,ity • Pat-r1_ee solid metal to ri`fikon With more than 25 million modules deployed around prevents hi-akag-ariacorros orthe world,SunPower technology is proven to last That's why we stand benind our module and microinverter with the industrys best 25-year Combined Power and Product Warranty;including the highest Power Warranty in solar .tk?1 iTF. L Factory-integratedMicroinverter Q 4� • SiniDler,faster r}sta l to^ �2`+c • Int ratei-d wire maern O rc1,n.IC.I S':Utd0wt} a 534t more • Er:grne-rest aci cailb ale a k;y [ "` conventional Modulepower 84% SIMPavv,er for Sun''i)we [ od � 1 in year 3 so4F 25 o - Years of operation Datasheet E-Series: E20-327 I E19-320 SunPower-1 Residential AC Module • Inverter Model:Enphase IQ 7XS(IQ7XS-96-ACM-US) @240 VAC @208 VAC .................... .................................... ................­­_........... ............................... Peak Output Poove, 320 VA. 320 VA ---._.....................­.............................................. Niay Contiritio,j',Output Po*er 315 VA 315 VA Nor-, (L.L)vrilrage/Range'(V) 2401211-264 208/183-229 ... ................... ..................­................... I.............I...... . .. ................... ....................................... ......... ............... .... ...................................-.................... ­­­........... ... .................. . ..... ....... Max 131 151 May l.'ri,t.sr-er2OA(Lil)Brar,rh(ir(i.ii-.' 12(sine phase) 10(two.pole)wye ............— .......... ............................................................ ......... EC We.ignte-i Fff it if-rlcy 975% 97 0% Nom Fir,cluenry 60 H,7 ...............I............................................-......... .......................- .................................................................... .... .. ............................................................... ....................................... .............. .............. E)it,1 id e-i Fle q L le',C/Rare e 4:1 6.8 Hz AC Short Circuit fault Currert Over Cycles 5 8 A ins Ovprvol;i,ge illzis5 AC Port III— AC Part 1­1,feed C,,rt*,,rt 18 rriA pova"Pr Factc-r 10 _r Fact ( d1j::,­,-1r.1!e! 0.7 lead C,7 01a:,f- v ln;is t. tee p ria S e i t„L, ora ........... ... ........... SPR-E20-327-E-AC SPR-E19-320-E-AC 25 yeai limited power wai rany .......... J 1 Warranties 25-vecii limited,procl,:­-warrdnl- y 1 NOITI Power I(Pnorri) 327W 320W ... ................... . ..... .............. .............................................................. ................................ ........... OL 1703 Power Tal 51-;!alt 'S 0% UL 174I 'IFFF-1547 1 I Module Effirier-.Cy Certificavorts 9 9% i UL 1741 AC Mciduie(Type fire rated) and Temp Coef (Power} -0 3-'.)%/1C -0 3590 "CU: 62109-1/IEC 62109- 1 Comp FCC Part 15 Class B -Three bypass diodes ICES.3003 Class B Shade T01 -Integrated rrodule leve:rr-aximorn CAN./CSA C22 2 NO 107 1.0 power pol!it ti ack.i CA Ri:e 21( l_1741 SA), ................... .................................. (includes Volt/Var and Reactive Power Prioi:Ly) UL Listed PV Rapid Shutdown Louipmen Operating Temp -40°F to+I8YF(-40°C to+85°C) ................_.._.............................................................................. Eriab,es instailationm actor dance win Max ArnbientTer9p . NFC 6,90.6(AC module) .......................................................................................................................................... .................................. Winn.62 psf,3000 Pa,305 kg/m2 front&back NEC 69012 Rapid S iutdown(inside and outside the array) NEC: 690 :5 AC Connectors,690 33(A)-(E)(1) Show 125 psf,6000 Pa,611 kg/m2front .................... ............_._........... .......................................................... Impact:Resistance 1 inch(25 mm)diameter had at 52 mph(23 m/z.;) Wrien used with invislMourit racking and InvisiMount accessories (UL 2703) E Module grounding and banding through riv-silvIou int I Solar Cells 96 Monocrystailine Maxecir.Gen III ... ........ 1 1 -Class A fire rated . .. High transmiss on tempered glass with Wirer used with AC module Q Cable,.,and ao,essciviesLIL 6703 and i Front Gass anu-reflective coating UL 2238)1 Divaor.rhental Ravi�.,, Oucdo-o! rated I i -Ratea for load break disconnect ........................ PZTest Potential rdL;ced degradation°r--e - Frame Class 1 blarkanodized(highe,[AAMA,eiting) ..................................................... . ............. ................... Weight 42 9 Iris(19 5 kg) ............................. .......... Recommended Max 1 3 in (33 rnm) Module Spacing 1 SunPowe,.360 W compared to.3 convent,nnal moaule on same sized arrays()60 VI.,,16;K 46 inri efficient,appro),--.6 m'),415niore energy per watt(based on third party module characteri7ation and PVSim),rj 75'4/yr slower clogradarl or.(Campeau,7 et A'S.jnPower Module Degradation Rate,"SunPower while paper 2011) 2 Based on,eatJi cl dau-sheet.value%ft orn webstres of top 10 0 rnahufactu i ei s per'H5, 10"mm 30mm— January 2o17 (411 in,) 9#1rank in FiitinnafeiPVDur at);I;tylrit?'at:vefor Solar tvlodLt2p.a;-Part 3'*PVTochPower 11.2 inj Magaztre.2015 Cempem,Z.etal Rate,"SunPowerwNte paper 2013 4Farl-oryset in I547a 2r14uefaulrsett.nj,!S C,Riile?l 39.9 mm comm,ssicnmg for more informati-i. 55taiid,afdTesrC,)!idit:,,n.-..(1.-jM'W/rn,iriadia,i(.e AMI 5,25°C)NRELralibrat-or standard SOMSruirent LACCSFFond4oltage All DC voltage.-.fullycontained within the module 431 mit, 6 This P,odu r I is UL Lf s!ec,as P',RS arra c on fo i ms with IN EC 2014 and NFC 20-,7 690 7?, [��2 m., aria C22 1-201'�Rule 64- k 218 Rapid shutdown of PV Systerns, r AC and or orduz twt,. When installed according te)manufacturei's instrurt-ons See V.WW,U9povve,comifa(ts for mo,e refeferire,inicrmation, For m3it details,see extenced data3hee,"ov sonpower comidetasheets 42018 SunPowe,Corporation Ad Rights Resf-ived SUNPOWER.rhe C`W E R8 Specificationsincluded.iriths dalasheet are subject to.changewithout notire LISTED EAM3 Mo&6 fwliopf. S N PO SU NPOWERIogo and NIA,<EON are registered traciernaris of SunPowe, corporation it the Ll S and ti her countries as weli 1-800-SUNPOWER Plea.'.,e ieau(hl:z Safe,iy TO,!C,'?talis 531948 RevA sunpovver.corn F y � PV -SA 1 — NEW EQUIPMENT — — — — EXISTING SERVICE.. . • • AC—COMBINER PANE I... 120/240,/741, 1 PH, 3W { AC—CMEI-1 _.,. ............ ............. ......... .... y ..... ......... (Pu LOAD- ONLY) PV-SA-2 300A K 1,11 H E . .. ism 4 • .. 2 i PV—SA— i, n... . •r - BKR-1 AC—DSC-1 r r r AC DISCONNECT ^L gp F� PJ—SA-4 -- - BKR-4 �MAIN PV—SA.....b • • • a I • • • 2 F34R-5 A V 1.FUSED:.. 131 R....,6 I Ecr, I N EGC f I TEGC EXISTING ACC PANEI.EXISTING I GEC GEC 6 CU i . PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Schill, Mark NLOGIC" 1050 Waterview Drive Southold, NY 11971 ENERGY ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Schill-3LD1 Revision: 1 Revised: 10/16/19 EQUIPMENT & COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 10-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 10-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 10-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 10-MODULES PV-SA-5 PHOTOVOLTAIC SUB-ARRAY ENPHASE IQ7XS-96-ACM-US, 1-CIRCUIT OF 10-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX. AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 3270 WATTS 211-264 VAC 13.30 A AC 240 V, AC PV-SA-2 3270 WATTS 211-264 VAC 13.30 A AC 240 V, AC PV-SA-3 3270 WATTS 211-264 VAC 13.30 A AC 240 V, AC PV-SA-4 3270 WATTS 211-264 VAC 13.30 A AC 240 V, AC PV-SA-5 3270 WATTS 211-264 VAC 13.30 A AC 240 V, AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Schill, Mark GREENLOGIC`` 1050 Waterview Drive ct ENERGY Southold, NY 11971 ELIMINATING THE COST OF ENERGY _ 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 3 Drawing No: Schill-3LD1 Revision: 1 Revised: 10/16/19 f � EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL 250V, 200A, NEMA-1, 1-PH,3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND,2-POLE, 20A BKR-2 CIRCUIT BREAKER,PV-SA-2 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-4 CIRCUIT BREAKER, PV-SA-4 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-5 CIRCUIT BREAKER,PV-SA-5 MATCH AC COMBINER PANEL BRAND,2-POLE,20A AC-DSC-1 AC DISCONNECT SWITCH(LINE TAP) 250V,60A, NEMA-1, FUSED; FUSE RATING:60A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4"PVC-40 12 / 6 B THWN-2 2"PVC-40 4 / 6 C THWN-2 2"EMT 4 / 6 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE,DISTANCE,AND DERATING FACTORS. 2.)ELECTRICAL CONDUIT TO BE MIN.PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIREMENTS. 4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Schill, Mark UO3REENLOGIC0 1050 Waterview Drive01 � ENERGY Southold, NY 11971 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Schill-3LD1 Revision: 1 Revised: 10/16/19