Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
44827-Z
�o�SUFfnt o Town of Southold 7/14/2020 G , o y� P.O.Box 1179 co rn s 53095 Main Rd o4 oo�`sy'1' Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41250 Date: 7/14/2020 THIS CERTIFIES that the building ALTERATION Location of Property: 2565 Vanston Rd, Cutchogue SCTM#: 473889 See/Block/Lot: 111.-6-7 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/13/2020 pursuant to which Building Permit No. 44827 dated 6/2/2020 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: air conditioning as applied for. The certificate is issued to Benjamin,David&Erica of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 44827 6/24/2020 PLUMBERS CERTIFICATION DATED C Authorized Signature O�SufFo1��o TOWN OF SOUTHOLD oy BUILDING DEPARTMENT y z TOWN CLERK'S OFFICE oma, 4SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 44827 Date: 6/2/2020 Permission is hereby granted to: Benjamin, David & Erica 18 Adelphi Dr Greenlawn, NY 11740 To: install an AC unit as applied for. At premises located at: 2565 Vanston Rd, Cutchogue SCTM # 473889 Sec/Block/Lot# 111.-6-7 Pursuant to application dated 3/13/2020 and approved by the Building Inspector. To expire on 12/2/2021. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $200.00 CO-ALTERATION TO DWELLING $50.00 ELECTRIC $85.00 1: $335.00 Buildinb Inspector Form No..6 TOWN OF SOUTH"'LD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy -New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. Z3Z,2z2 New Construction: / Old or Pre-exiBuilding: 1/ (check one) Location of Property: �� astine h Ue � House No. Street y� Hamlet Owner or Owners of Property: 5_/ Ca Suffolk County Tax Map No 1000, Section // / Block Lot DCJ 7 Subdivision I Filed Map. Lot: L ( Permit No. LM;n Date of Permit. Applicant: P&J,() Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: V (check one) Fee Submitted: $ 6D Applicant Signature CONSENT TO INSPECTION Gn Ca �-i VI'D .moi yip-!�/� , the undersigned, do(es)hereby state: Owner(s)Name(s) That the undersigned(is)_(are)the owner(s) of the premi es in the Town of Southold, located at .�lp �� �o which is shown and designated on the Suffolk County Tax Map as District 1000, Section//l , Block /, 6 , Lot �jd That the undersigned(has) (have) filed, or cause to be filed, an application in the Sout old Town Buildingn$ ector's Office for the following: �r L it That the undersigned do(es)hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon,to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws, ordinances, rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections, do(es) so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances, rules or regulations of the Town of Southold. Dated: (Si nature) Z, rint e ,n ign e) (I (Print Name) Town Hall Annex ® Telephone(631)765-1802 54375 Main Road `tom Fax(631)765-9502 P.O.Box 117 Southold,NY 11971-0959 sean.devlinAltown.Southold.ny.us �` � BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To- David Benjamin Address: 2565 Vanston Rd city,Cutchogue st: NY zip- 11935 Building Permit#. 44827 Section: 111 Block: 6 Lot. 7 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Hartig Electric License No: 4084ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic X Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures 1 Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures Smoke Detectors Main Panel A/C Condenser 2 Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower 2 Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency FixtureTime Clocks Disconnect 2 Switches 4'LED Exit Fixtures Pump Other Equipment: 1-AC and 1- Minisplit, AH in Attic Notes: AC Inspector Signature: Date: June 24, 2020 S.Devlin-Cert Electrical Compliance Form.xls FIELD INSPECTION REPORT DATE COMMENTS to FOUNDATION(1ST) y -------------------------------- FOUNDATION (2ND) O ROUGH FRAMING& y I PLUMBING r INSULATION PER N.Y. (7) H STATE ENERGY CODE FINAL ADDITIONAL COMMENTS 0 , z iH x b H TOVIN;;F SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST ff3U1 SING DEPARTMENT Do you have or need the following,before applying TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX:(631)765-9502 Survey Southoldtownny.gov PERMIT NO. Check Septic Form NYSDEC Trustees C 0 Application Flood Permit Examined 20 Single&Separate Truss Identification Form Storm-Water Assessment Form 70 Contact: Approved 20 aInpecto Mail to Disapproved a/c ,$ 1f i Phone / / q ►! 7L/v Expiration —20r b-6 —4,j S K �.,.,, ., - _ C -D ���i �.��4 � �"'� y APPLICATION FOR BUILDING PERMIT , � I l € Date ��rG�vl 3 ,200 2020 INSTRUCTIONS MAR 1 3' a This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 seTslO, pl s'?accgggc plot plan to scale.Fee according to schedule. F b..Pro plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or meas,and�watelways) ,D c.The work covered by this application may not be commenced before issuance of Building Permit d.Upon approval of this application,the Building Inspector will issue a Building Permitto the applicant Such a permit shall be kept on the premises available for inspection throughout the work e No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy f Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months Thereafter,a new permit shall be required APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described The applicant agrees to comply with all applicable laws,ordinances,building code, ou ng code, d re a on and to admit authorized inspectors on premises and in building for necessary inspections Sig ature of a plical t or name, a corporation) Aly (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder Name of owner of premises'/ C� al4d &, 13ew a,4mi (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer (Name and title of corporate officer) 1,R,1J FRAN r%1/ O Builders License No. Plumbers License No. I �,� 9 C�LVV FU Electricians License No. ` ` G e a ruff CERTIFICATE ERTI FI CAT Other Trade's License No. U ���l°° 1. Locatign of land on which proposed Vork will e done: O ® O U PANCV, a�(o� i/�t�f�yn Crr�ca�'�� II�Toti§6Nbmbb,'' 'cf),(°�98treet Hamlet qCdu�ty T Map Nol IMF io �� Block 6 Lot 90 7 _),ATE: ty aYS.i . =CEr �E�l� MIwY BUILDING% DEBART MEN T AT 765-1802 8 AM TO l FAli FOIR Ti IE FOLLOWING INSPECTIONS: COMPLY WITH ALL CODES OF •I. FOUNDATION - T''ViC REQUIRED NEW YORK STATE & TOWN CODES FOR POURED CONCRETE AS REQUIRED F 2. ROUGH - FRAkiliNG & PLUiv BiNG 3., INSULATION SOUTHOLD TOWN Z 4. FINAL -• CON'STRUC'TION MUST SOUTHO N PLANNING BOARD BE COMPLE I E FOR C.O. ALL CONSTRUCTI0,N Si-IALL MEET THE S HOLD TOWN TRUSTEES REQUIREMENTS OF THE CODES OF NIEW YORK STATE. NOT RESPCNSIBLE FOR N.Y.S.DE DESIGN OR CONSTRUCTION ERRORS. Subdivision Filed Map No. Lot 6 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy -r/.4g/,C =lei 4w—//j t 0 b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work_ e-CuYlei.-ti l�y (Description) 4. Estimated Cost Fee (To be paid on'filing this application) 5. If dwelling,number of dwelling units_ Number of dwelling units on each floor If garage, number of cars / 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO 13.Will lot be re-graded?YES NO Willexcessfill be removed from premises?YES NO p 14.Names of Owner� misesV Address Phone No. S �'6�'" a Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO X *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to,this property?* YES NO—K� * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS. COUNTY OF JgZalV- ) Jy �i A 6Q.-j <q PL"ed being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the o__r (Contractor,Agent,Corporate Officer,etc) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application, that all statements contained in this application are true to the best of his knowledge and belief,and that the work will be performed in the manner set forth in the application filed therewith Sworn to before me this 3 day of f C 20'1—�D d—� NotaryYu i Signa r ofAppl cant Kenneth C.Henry,Jr. NOTARY PUBLIC,State of Newyork No.02HE5030473 Clualified in Suffolk County Term Expires July 18. �, �y Air Air Conditioners ' D RA16 Series t The new degree of comfort:" - Rheem Classic° Series Air Conditioners RA16 Series Efficiencies up to 16 SEER/13 EER Nominal Sizes 11/2 to 5 Ton [5.28 to 17.6 kW] Cooling Capacities 17.3 to 60.5 kBTU [5.7 to 17.7 kW] C O usprK— 0 Lffim r s "Proper sizing and installation of equipment is critical to achieve optimal performance.Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystargov" • Composite base pan-dampens sound, captures louver • Diagnostic service window with two-fastener opening- panels, eliminates corrosion and reduces number of fasteners provides access to the high and low pressure. needed • External gauge port access-allows easy connection of • Powder coat paint system-for a long lasting professional finish `low-loss"gauge ports • Scroll compressor-uses 70%fewer moving parts for higher • Single-row condenser coil-makes unit lighter and allows efficiency and increased reliability thorough coil cleaning to maintain "out of the box" • Modern cabinet aesthetics-increased curb appeal with visu- performance ally appealing design • 35%fewer cabinet fasteners and fastener-free base-allow • Curved louver panels-provide ultimate coil protection, for faster access to internal components and hassle-free enhance cabinet strength, and increased cabinet rigidity panel removal • Optimized fan orifice-optimizes airflow and reduces unit • Service trays-hold fasteners or caps during service calls sound • QR code-provides technical information on demand for • Rust resistant screws-confirmed through 1500-hour salt faster service calls spray testing • Fan motor harness with extra long wires allows unit top to be • PlusOneTM Expanded Valve Space-3"-4"-5" service valve removed without disconnecting fan wire. space-provides a minimum working area of 27-square inches for easier access • PlusOneTM Triple Service Access-15" wide, industry lead- ing corner service access-makes repairs easier and faster. The two fastener removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed,for faster coil cleaning and easier cabinet reassembly COMFORTE-000 INTEGRATED HOME FORM NO All-222 REV 8 Air Table of Contents , RAi6 Series TABLE OF CONTENTS StandardFeature......................................................................................................3 AvailableSKUs ........................................................................................................3 Features&Benefits ..............................................................................................4-5 Model Number Identification ................................................................................6-7 General Data/Electrical Data....................................................................................8 Accessories ............................................................................................................9 WeightedSound Power............................................................................................9 UnitDimensions......................................................................................................10 Clearances.......................................... ...................................................................11 WiringDiagrams ....................................................................................................12 ApplicationGuidelines............................................................................................12 Refrigerant Line Size Information......................................................................13-16 PerformanceData ..................................................................................................17 GuideSpecifications ..............................................................................................18 LimitedWarranty ....................................................................................................19 COMFORTINTEGRATED HOME ' Air Standard Feature/Available SKUs 0 RAI 6 Series Standard Feature Table STANDARD FEATURES Feature 18 24 30 36 42 48 60 R-410a Refrigerant ✓ J J J ✓ ✓ J Maximum SEER 16 16 16 16 16 16 16 Maximum EER 13 13 13 13 13 13 13 Scroll Compressor ✓ J J ✓ ✓ ✓ J Field Installed Filter Drier J ✓ J J J J ✓ Front Seating Service Valves ✓ J J J ✓ J ✓ Internal Pressure Relief Valve ✓ ✓ ✓ ✓ ✓ J ✓ Internal Thermal Overload J ✓ ✓ J J ✓ ✓ Long Line capability J ✓ ✓ J ✓ ✓ J Low Ambient capability with Kit ✓ ✓ ✓ ✓ J ✓ J 3-4-5 Expanded Valve Space J ✓ ✓ J ✓ J ✓ Composite Basepan ✓ ✓ J J J ✓ J 2 Screw Control Box Access J ✓ J J J ✓ ✓ 15°Access to Internal Components J ✓ J ✓ J J ✓ Quick release louver panel design ✓ J J ✓ ✓ J ✓ No fasteners to remove along bottom ✓ J ✓ J ✓ ✓ ✓ Optimized Venturi Airflow J ✓ ✓ ✓ J ✓ J Single row condenser coil J ✓ J ✓ J ✓ J Powder coated paint J J J J ✓ ✓ ✓ Rust resistant screws ✓ J J ✓ J J ✓ QR code ✓ J ✓ J ✓ ✓ ✓ External gauge ports J J J J J J ✓ Service trays ✓ J J J J J ✓ J=Standard Available SKUs Available Models Description RA1618AJl NA C/assi&Series 11/2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1618AJl NB Classic®Series 11/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1624AJl NA Classic®Series 2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1624AJINB Classic®Series 2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1630AJl NA Classic®Series 21/2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1630AJINB Classic®Series 21/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1636AGl NB Classic®Series 3 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1636AJl NA Classic®Series 3 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1636AJl NB Classic"Series 3 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1636BC1 NB(Canada) Classic®Series 3 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1642ACl NB Class/c®Series 31/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1642AJl NA Classic®Series 31/2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1642AJl NB Classic®Series 31/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1648ACl NB Class/c®Series 4 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1648AJl NA Classic®Series 4 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1648AJI NB Classic®Series 4 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1660ACl NB Classic®Series 5 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1660AJl NA Classic®Series 5 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1660AJl NB Classic®Series 5 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 INTEGRATED HOME COMFORT Air Features&Benefits RAI 6 Series ` Introduction to RA16 Air Conditioner The RA16 is our 16 SEER air conditioner and is part of the Rheem air conditioner product line that extends from 13 to 20 SEER.This highly featured and reliable air conditioner is designed for ears of reliable,efficient operation when matched 12 with Rheem indoor aluminum evaporator coils and furnaces or air handler units with aluminum evaporators. VIIIIIIIIIIIIIIII1 Our unique composite base(5-1) reduces sound emission,elimi- nates rattles, significantly reduces fasteners, eliminates corro- If in the rare event, greater access is needed to internal compo- sion and has integrated brass compressor attachment inserts nents,such as the compressor,the entire corner of the unit can (0). Furthermore it has incorporated into the design,water be removed along with the top cover assembly to have unprece- management features,'means for hand placement(Efl)for unit dented access to interior of the unit(H). Extra wire length is maneuvering,screw trays(®)and inserts for lifting off unit incorporated into each outdoor fan and compressor so top pad. cover and control panel can be positioned next to the unit.With minimal effort the plug can be removed from the compressor 1❑ and the outdoor fan wires can be removed from the capacitor to allow even more uncluttered access to the interior of the unit(EN). Outdoor coil heights range from as short as 27"to 48",aiding access to the compressor. Disassembly to this degree and com- plete reassembly only takes a first time service technician less _, than 10 minutes. (15) Service Valves(©)are rigidly mounted in the composite base -' with 3" between suction and discharge valves,4" clearance below service valves and a minimum of 5" above the service valves,creating industry leading installation ease.The minimum 27 square-inches around the service valves allows ample room to remove service valve Schrader prior to brazing, plenty of clear- ance for easy brazing of the suction and discharge lines to ser- vice valve outlets,easy access and hookup of low loss refriger- All units utilize strong formed louver panels which provide indus- ant gauges([fl),and access to the service valve caps for try leading coil protection. Louver removal for coil cleaning is opening. For applications with long-line lengths up to 250 feet accomplished by removing one screw and lifting the panel out of total equivalent length, up to 200 feet condenser above evapora- the composite base pan.(17)All RA16 units utilize single row tor, or up to 80 feet evaporator above condenser,the long-line coils(15)making cleaning easy and complete, restoring the instructions in the installation manual should be followed. performance of the air conditioner back to out of the box perfor- mance levels year after year. 51 _ 9 Controls are accessed from the corner of the unit by removing only two fasteners from the control access cover, revealing the The outdoor fan motor has sleeve bearings and is inherently industry's largest 15 wide and 14 tall control area(®).With all protected.The motor is totally enclosed for maximum protection this room in the control area the high voltage electrical whip(Os ) from weather,dust and corrosion.Access to the outdoor fan is can easily be inserted through the right size opening in the bot- made by removing four fasteners from the fan grille.The outdoor tom of the control area. Routing it leads directly to contractor fan can be removed from the fan grille by removing 4 fasteners lugs for connection.The low voltage control wires(ED are easily in the rare case outdoor fan motor fails. connected to units low voltage wiring. If contactor or capacitor (11) needs to be replaced there is more than adequate space to Each cabinet has optimized composite(is)fan orifice assuring make the repair. Furthermore, if high pressure and low pressure efficient and quiet airflow. model was not purchased but is desired to be installed in the field,the service window(iz)can be removed by removing two screws,to access the high and low side Schrader fittings for easy I `:' is field installation.The entire corner can be removed providing ultimate access to install the high and low pressure switch. (13) INTEGRATED HOME COMFORT Air Features&Benefits �i I RA16 Series The entire cabinet has powder post paint(20)achieving 1000 Optional Accessories hour salt spray rating,allowing the cabinet to retain its aesthetics (Refer to accessory chart for model#) throughout its life. Compressor Crankcase Heater Protects against refrigerant migration that can occur during low 20 ambient operation Compressor Sound Cover • Reinforced vinyl compressor cover containing a 11/2 inch thick ' batt of fiberglass insulation 22 21 •Open edges are sealed with a one-inch wide hook and loop fastening tape Compressor Hard Start Kit Scroll compressors with standard internal pressure relief and •Single-phase units are equipped with a PSC compressor internal thermal overload are used on all capacities assuring motor,this type of motor normally does not need a potential longevity of high efficient and quiet operation for the life of the relay and start capacitor product. • Kit may be required to increase the compressor starting Each unit is shipped with filter drier for field installation and will torque, in conditions such as low voltage trap any moisture or dirt that could contaminate the refrigerant Low Ambient Kit system. •Air conditioners operate satisfactorily in the cooling mode down to 55°F outdoor air temperature without any additional ss controls •This Kit can be added in the field enabling unit to operate properly down to 00 in the cooling mode •Crankcase heater and freezestat should be installed on com- pressors equipped with a low ambient kit 3"/6"/12" All cabinets have industry leading structural strength due to the •Gray high density polyethylene feet are available to raise unit composite base pan(9j]),interlocking corner post(E),formed off of mounting surface away from moisture curved louver panels @s)and drawn top cover(2a)making it Low Pressure the most durable cabinet on the market today. •Can be added in field enabling the unit to shut off compressor Each RA16 capacity has undergone rigorous psychometric test- on loss of charge ing to assure performance ratings of capacity,SEER NOTE: Unit can be purchased with high and low pressure and EER per AHRI Standard 210/240 rating condi- c@ us installed at factory. (Refer to SKU list) tions.Also each unit bears the UL mark and each unit mm is certified to UL 1995 safety standards. High Pressure •Can be added in field enabling unit to shut off compressor if Each unit has undergone specific strain and modal testing to unit loses outdoor fan operation. assure tubing(2e)is outside the units natural frequency and that the suction and discharge lines connected to the compressor NOTE: Unit can be purchased with high and low pressure withstand any starting,steady state operation or shut down installed at factory. (Refer to SKU list) forces imposed by the compressor. Decorative Top All units have been sound tested in sound chamber to AHRI 270 •Can be installed on fan grille rating conditions, and A-weighted Sound Power Level tables produced, assuring units have acceptable noise qualities(see page 9). Each unit has been ran in cooling operation at 95°F and 82°F and sound ratings for the RA16 range from as low as 70.7 dBA to 76.6 dBA. All units have been ship tested to assure units meet stringent "over the road"shipping conditions. As manufactured all units in the RA16 family have cooling capa- bility to 55°F.Addition of low ambient control will allow the unit to operate down to 0°F. Factory testing is performed on each unit.All component parts meet well defined specification and continually go through receiving inspections. Each component installed on a unit is scanned, assuring correct component uti- lization for a given unit capacity and voltage.All condenser coils are leak tested with pressurization test to 550#'s and once installed and assembled, each units'complete refrigerant system is helium leak tested.All units are fully charged from the factory for up to 15 feet of piping.All units are factory run tested. The RA16 has a 10-year conditional compressor and parts war- ranty(registration required). COMFORTINTEGRATED HOME aditioners JLb R A 16 24 A J 1 N A D Brand Product SEER Capacity Major Series* Voltage Type Controls Minor Series** Option a 3 Category BTU/HR Code y " Rheem A-Air Conditioners 16- 16 SEER 18- 18,000 [5.28 kW] A- 1st Design J -1 ph,208-230/60 1 -Single-stage N - Non-Communicating A-1 st Design N/A 3 24-24,000 [7.03 kW] B-2nd Design C-3ph,208-230/60 B-2nd Design 30-30,000 [8.79 kW] CD 36-36,000 [10.55 kW] 42-42,000 [12.31 kW] 3 48-48,000 [14.07 kW] 60-60,000 [17.58 kW] *See page 3 for available SKUs. 0s (For •• R P 14 24 A J 1 N A Brand Product SEER Capacity Major Series* Voltage Type Controls Minor Series** Option Category BTU/HR Code Rheem P-Heat Pump 13-13 SEER 18-18,000 [5.28 kW] A-1st Design J-1 ph,208-230/60 1 -Single-stage C-Communicating A-1st Design N/A 14-14 SEER 24-24,000 [7.03 kW] C-3ph,208-230/60 2-Two-stage N-Non-Communicating • 15-15 SEER 30-30,000 [8.79 kW] D-3ph,460/60 V-Inverter 17-17 SEER 36-36,000[10.55 kW] P-Piston 20-20 SEER 42-42,000[12.31 kW] • 48-48,000[14.07 kW] 60-60,000[17.58 kW] CoilsFurnace 1 '' R C F 24 17 S T A M C A Brand Product Type Capacity Width Efficiency Metering Major Orientation Casing Minor Series** Option Category BTU/HR Device Series* Code Rheem C-Evap Coil F-Furn Coil 24-24,000 [7.03 kW] 14-14" S-Standard Eff. T-TXV A-1st Design M-Multipoise C-Cased A-1st Design N/A H-Air-Handler 36-36,000[10.55 kW] 17-17 5° M-Mid Eff. E-EEV V-Vertical only/ U-Uncased Coil 48-48,000[14.07 kW] 21 -21" H-High Eff. P-Piston convertible 60-60,000[17.58 kW] 24-24.5" H-Ded. Horizontal only —Model number ID's are for reference only.See available SKU page of applicable spec sheet for table of available SKU's for a specific model. [ ]Designates Metric Conversions 1 ' o+ AFUE Gas Furnaces (For Reference)** R 96 V A 70 2 3 17 M S A Brand Series Motor Major Rev Input Stages Air Flow Cabinet Configuration Nox Minor Rev BTU/HR Width Rheem 90-90 AFUE V-Variable speed A-1 st Design 040- 42,000[12.31 kW] 1 -Single-stage 3-up to 3 ton 14-14" M-Multi X-Low Nox A-1st Design 92-92 AFUE T-Constant 060- 56,000[16.41 kW] 2 -Two-stage 5-31/2 up to 5 ton 17-17.5" S-Standard 95-95 AFUE Torque 070- 70,000[20.51 kW] M-Modulating 21-21" 96-96 AFUE (X-13) 085- 84,000[24.62 kW] 24-24.5" 97-97 AFUE P-PSC 100- 98,000[28.72 kW] 115-112,000[32.82 kW] il ' i ■. R 80 2 V A 075 3 17 M S A Brand Series Stages Motor Major Rev Input Air Flow Cabinet Configuration Nox Minor Rev BTU/HR Width Rheem 80-80+AFUE 1 -Single-stage V-Variable speed A-1st Design 050- 50,000[15 kW] 3-up to 3 ton 14-14" M-Multi X-Low Nox A-1 st Design 2 -Two-stage T-Constant Torque(X-13) 075- 75,000[22 kW] 4-21/2 to 4 ton 17-17.5" D -Down S-Standard P-PSC premium 100-100,000[29 kW] 5-31/2 up to 5 ton 21 -21" Z -Down& S-PSC standard 125-125,000[37 kW] 24-24.5' zero clearance 150-150,000[44 kW] down flow J or ■. R H 1 T 36 17 S T A N A A 000 Brand Product Stages of Motor Type Capacity Width Coil Size Metering Major Controls Voltage Minor Factory Heat Option Category Airflow BTU/HR Device Series* Series** Cap Code • Rheem H-Air 1 -Single-Stage V-Variable 24-24,000 [7.03 kW] 14-14" S-Standard T-TEV A-1st Design C-Communicating A-1 ph,115/60 A-1st Design 00-no *TBD Handler 2-Two-Stage Speed 36-36,000[10.55 kW] 17-17.5' Eff. E-EEV N-Non-comm J-1 ph,208-240/60 factory heat M-Modulating T-Constant 48-48,000[14.07 kW] 21 -21" M-Mid Eff. P-Piston D-3ph,480/60 with option Torque 60-60,000 117.58 kW] 24-24.5" H-High Eff. code P-PSC **Model number ID's are for reference only.See available SKU page of applicable spec sheet for table of available SKU's for a specific model. [ ]Designates Metric Conversions J L6 a 0-• a rn m N Z CD c co 3 4J O' N a (D 3 n w 0 n General Data/Electrical Data a Air I RAI 6 Series Physical Data PHYSICAL DATA Model No. RAI 618 RA1624 RA1630 RA1636 RA1636 RA1642 RA1648 RAI 660 Nominal Tonnage 1.5 2.0 2.5 3.0 3.0 3.5 4.0 5.0 Valve Connections Liquid Line O.D.-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line O.D.-in. 3/4 3/4 3/4 3/4 3/4 7/8 7/8 7/8 Refrigerant(R410A)furnished oz.s 82 87 113 108 108 150 174 201 Compressor Type Scroll Outdoor Coil Net face area-Outer Coil 12.1 14.8 16.2 18.8 17.29 24.2 28.3 32.3 Net face area-Inner Coil - - - - - - - - Tube diameter-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Number of rows 1 1 1 1 1 1 1 1 Fins per inch 22 22 22 22 22 22 22 22 Outdoor Fan Diameter-in. 20 24 26 26 24 26 26 26 Number of blades 3 2 3 3 3 3 3 3 Motor hp 1/8 1/6 1/5 1/3 1/6 1/3 1/3 1/3 CFM 2405 2850 3915 4340 3300 4450 4660 4775 RPM 1095 851 710 819 825 829 828 795 watts 155 147 102 131 167 193 198 239 Shipping weight-lbs. 147 149 159 177 199 212 232 247 Operating weight-lbs. 140 142 152 170 192 205 225 240 Electrical Data - Line Voltage Data(Volts-Phase-Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-601208/230-1-601208/230-1-601208/230-1-60 Maximum overcurrent protection(amps)2 20 20 30 35 35 40 1 40 1 50 Minimum circuit ampacity3 12 14 18 23 23 25 1 25 1 34 Compressor Rated load amps 1 9 1 10.3 1 12.8 1 15.4 1 15.4 16.7 17 23.7 Locked rotor amps 47.5 61.6 67.3 839 83.9 109 123.9 152.5 Condenser Fan Motor Full load amps 0.7 0.6 2.8 3.5 1.5 3.5 3.5 3.5 Locked rotor amps 1.3 1.5 2.3 - .8 - 2.3 - Line Voltage Data(Volts-Phase-Hz) - - - 208/230-3-60 2081230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 Maximum overcurrent protection(amps)2 - - - 25 20 25 30 35 Minimum circuit ampacity3 - - - 17 14 18 21 24 Compressor Rated load amps - - - 10.4 10.4 11.2 13.6 15.9 Locked rotor amps - - - 73 73 88 83.1 110 Condenser Fan Motor Full load amps - - - 3.5 .8 3.5 3.5 3.5 Locked rotor amps - - - - 1.5 - 2.3 - �Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 311efer to National Electrical Code manual to determine wire,fuse and disconnect size requirements. INTEGRATED HOME .- -90 Air I Accessories/Weighted Sound Power/Thermostats 0 RA16 Series Accessories Model No. RA1618 RA1624 RA1630 RA1636 RA1642 RA1648 RA1660 Compressor crankcase heater* 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 44-17402-45 Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 Freeze Stat 50313 50313 50313 50313 50313 50313 50313 Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25 Compressor hard start kit SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 Low pressure control RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 High pressure control RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 20ORD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RO2T3TVLC 200RD3T3TVLC 200RD3T3TVLC (24 VAC,50/60 Hz) Solenoid Coil 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC (120/240 VAC,50/60 Hz) Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V Classic Top Cap w/Label 91-101123-21 91-101123-21 91-101123-21 91-101123-21 91-101123=21 91-101123-21 91-101123-21 *Crankcase Heater recommended with Low Ambient Kit. Weighted Sound Power Level (NA) - Unit Size-Voltage,Series Standard TYPICAL OCTAVE BAND SPECTRUM(dBA without tone adjustment) Rating(dBA) 125 250 500 1000 2000 4000 8000 RA1618 76.6 53.4 60 65.7 66.3 64.2 58.8 52.6 RAI 624 75.5 49.9 - 58.4 61.4 64.1 61.6 57.3 508 RA1630 74.3 48.4 57.4 62.6 64 5 61.5 56.5 51.5 RA1636 76.4 54.5 62.7 67.1 66.5 62.7 58.5 54.3 RA1636 75 56.1 58.7 63.1 66.1 62.3 59 55.7 RAI 642 70.7 47.5 51 60.2 60.7 59.7 53.6 50.4 RA1648 74.3 51.2 56.1 64.5 65.6 60.7 56.6 52.6 RAI 660 74.6 50.1 55.1 65.6 64.8 63.2 574 56.4 NOTE:Tested in accordance with AHRI Standard 270-08(not listed in AHRI) INTEGRATED • • •- Air Unit Dimensions a RAI 6 Series Unit Dimensions OPERATING SHIPPING MODEL H(Height) L(Length) W(Width) H(Height) L(Length) W(Width) N0. INCHES mm INCHES mm INCHES I mm INCHES mm INCHES mm INCHES mm RA1618 27 685 29.75 755 29.75 755 27.375 695 32.25 819 32.25 819 RA1624 27 685 33.75 857 33.75 857 27.375 695 36.25 921 36.25 921 RA1630 27 685 35.75 908 35.75 908 27.375 695 1 38.25 972 38.25 972 RA1636 31 787 1 35.75 908 35.75 908 31.375 797 38.25 972 38.25 972 RA1636 31 787 33.75 857 33.75 857 31.375 797 36.25 921 36.25 921 RA1642 39 990 35.75 908 35.75 908 39.375 1000 38.25 972 38.25 972 RA1648 45 1143 35.75 908 35.75 908 45.375 1153 38.25 972 38.25 972 RA1660 51 1295 35.75 1 908 35.75 908 51.375 1305 1 38.25 972 1 38.25 972 ALLOW 60"[1524 mm] OF CLEARANCE A I W D 6 5 C H A L R G E • • H SERVICE PANELS/ INLET CONNECTIONS/HIGH&LOW VOLTAGE ACCESS ALLOW 24"[610 mm]OF CLEARANCE AIR INLET LOUVERS ALLOW 6"[152 mm]MIN.OF CLEARANCE ALL SIDES 12"[305 mm]RECOMMENDED [ ]Designates Metric Conversions ST-A1226-02-00 INTEGRATED10 . COMFORT CLEARANCES WALL WALL 6" . 24" 1—� 52'4) (609.6) Service 24" 12 12 (609:6) (304.8) (304.8) !!77: Service 6" (152.4). 6" - (152.4) 12" (304.8) 24" 24" 24" (609.6) (609.6) (609.6) Service Service Service 18" 24" 24„ (457.2) (609.6) (609.6) 24" recommended 24" recommended 6" minimum 6" minimum JL6 NOTE: NUMBERS IN () = mm D IMPORTANT When installing multiple units in an alcove,roof well or partially enclosed area,ensure there is adequate venbllahon to prevent re-circulation of discharge air 7D () a r� ST-A1225-01-00 m o 1.FD ti 0 'f1 AirI Wring Diagram/Application Guidelines �i RA16 Series Control Wiring FIGURE 2 *IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED,IT IS RECOMMENDED THAT CONTROL WIRING FOR GAS OR OIL FURNACE W1(WBK)AND W2(W/BL)BE JUMPERED TOGETHER. TYPICAL THERMOSTAT TYPICAL THERMOSTAT FOR TYPICAL GAS OR OIL HEAT SUBBASE FOR TYPICAL ELECTRIC HEAT SUBBASE (1) © QW ® Y G W R BR -BROWN WIRE YL -YELLOW WIRE BR-BROWN WIRE X -WIRE CONNECTION R-REO WIRE YL-YELLOW WIRE W/BK-WHITE WIRE WITH BLACK STRIPE GBK-GREEN WIRE WITH BLACK STRIPE PU-PURPLE WIRE(NOT USED) X-WIRE CONNECTION TYPICAL GAS OR TYPICAL ELECTRIC HEAT OIL FURNACE LOW VOLTAGE JUNCTION BOX * WBL TYPICAL CONDENSING R TYPICAL CONDENSING R UNIT UNIT X W/BK (-a/BK G YL YL Y YL BR BR BR PU Application Guidelines 1. Intended for outdoor installation with free air inlet and outlet.Outdoor fan external static pressure available is less than 0.01 -in.wc. 2. Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F(12.80% 3. Maximum outdoor operating air temperature is 125°F(51.70% 4. For reliable operation, unit should be level in all horizontal planes. 5. Use only copper wire for electric connections at unit.Aluminum and clad aluminum are not acceptable for the type of connector provided. 6. Do not apply capillary tube indoor coils to these units. 7. Factory—supplied filter drier must be installed. COMFORT12 INTEGRATED HOME Refrigerant Line Size Information 13-16 SEER Single-Stage Air-Conditioners Apply Long Line Guidelines it Equivalent Length(Feet) Allowable Allowable Linear Line Length Exceeds Unit Size Liquid Line Suction Line Those Shown Below (Feet) <25 26-50 1 51-75 1 76-100 1 101-125 1 126-150 1 151-175 1 176-200 1 201-225 226-250 Size Size (-)A14 (-)A14 (-)A13 A/B W (-)Al6 Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier 1/4" 5/8" N/A N/A N/A N/A 25/1.00 50/0.99 62/098 43/0.98 24/097 5/097 r NR` ,"" '. NR , N$` ,n #R. 5/16" 5/8" N/A 223 198 188 25/100 50/099 75/098 98/098 93/097 88/097 83/0.96 78/0,96 7310.95. 6810.94 1.5 Ton 3/8" 5/8" 178 148 132 125 25/1.00 50/099 75/098 100/098 100/0.97 100/0.97 100/A96 1 QO/'0.96- 100!0.95, , 100[0.94 **SEE NOTE 3 1/4" 3/4"** N/A N/A N/A N/A 25/100 50/100 62/099 43/099 24/099 5/099 5/16° 3/4"** N/A 223 198 188 25/100 50/1.00 75/099 98/0.99 1 93/0.99 88/0.99 83/099 78/098 73/0.98 68/098 3/8" 3/4"** 178 148 132 125 25/100 50/1.00 75/100 100/099 100/099 100/0.99 100/099 100/098 100/0.98 100/098 1/4" 5/8" N/A N/A N/A N/A 25/0.99 50/098 21/0.97 5/16° 5/8" 243 213 193 175 25/099 50/098 75/097 87/0.96 77/6.95 0/0,94 61/0.93 537 0.92 4510.91 3710.90 2 Ton 3/8" 5/8" 162 142 128 117 25/099 50/098 75/097 1001 0.96 ° 1661'0-65 =-11 95, 00/0 94'• 98/0.93; 95/0.92 9210 91, 89/0.901 1/4" 3/4" N/A N/A N/A N/A 25/100 50/100 21/099 5/16° 3/4" 243 213 193 175 25/100 50/100 75/099 87/0.99 77/0.98 69/0.98 61/098 53/097 45/097 3710.96 3/8" 3/4" 162 142 128 117 25/100 50/1 00 75/099 100/099 100/0.98 100/098 98/098 95/097 93/097 9010.96 5/16" 5/8" N/A N/A 133 110 25/099 50/098 7510.96 70/0.94 59/0.93 48/0.91 36/0:90 3/8" 5/8" 142 117 88 73 25/0.99 50/098 7510.96 10010.94- 981=0,93" 9 4!0.91 2.5 Ton 90/0.90. 5/16" 3/4" 213 175 133 110 25/1.00 50/0.99 75/099 70/098 1 59/098 48/097 36/0,96 25/0:96 13/0.95 3/8" 3/4" 142 117 88 73 25/100 50/099 75/099 100/0.98 98/0.98 94/097 90/0,96' -8610.96- 82 6.95, 78/0,95 • 5/16" 5/8" N/A N/A N/A N/A 25/0.99 50/097 :66/. --0.94`. =49/0.92-.)" ..32!0.90 _,Nfl`'..rm' 3/8" 5/8" 108 85 90 82 25/0.99 50/0.97 75/0,94- 95/0.92 891.0.90 y_NR- - , NR' #R . .: ,:-Aft"',PIf t",.. ° 5/16" 3/4° N/A 128 135 123 25/1 00 50/099 66/098 49/098 32/097 1510.96 Nfl 3 Ton 3/8" 3/4" 108 85 90 82 25/1 00 50/099 75/098 95/098 89/097 - 841.0.96. -781'0.95: : �72/0.94 -674%0.93- 61 L0,93"' _ 1/2" 3/4" 54 43 45 41 2511 00 50/099 75/098 100/0.98 100/0.97 100/0.96 A00/0,95 100/0.94 10010.93 10Q/0.93 -77 5/16" 7/8" WA 128 135 123 25/100 50/1 00 66/100 49/0.99 32/099 15/099 ='` ` NR"•+s;',s:9-r;NR;=; ';` #R"':.r,- :.``;.,NH;' 3/8" 7/8" 108 85 90 82 25/1 00 50/100 75/100 95/0.99 89/0.99 84/0.99 78/098 72/098 67/098 61/0.97 1/2" 7/8° 54 1 43 45 1 41 1 25/1 00 50/1.00 75/1.00 100/099 100/099 100/099 100/098 100/098 100/0.98 100/097 3/8° 3/4° 150 123 102 75 25/099 50/0.98 75/097 &810.96;: 80/0.95 7210.94� 65%0:92,`,- 57/0.91:-: 4910,80 �� 3 5 Ton 1/2" 3/4" 75 62 51 38 25/099 50/098 75/097 100/,0.96 , -16010.95 100/0.94 1001.0.92.. 10010.91 j 00/0.90- 3/8" 7/8" 150 123 102 75 25/1 00 50/100 75/099 88/099 80/099 72/0.98 65/0.97 57/097 49%0.96 42/0.96 D 1/2" 7/8" 75 62 51 38 25/100 1 50/100 75/099 100/099 100/0.99 100/098 1 100/097 100/097 1 -100/0.'96 1001-0.96- z � NOTES: D 1) Do not exceed 200 ft linear line length <n 2) `Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit m w 3)-3/4'suction line should only be used for 1.5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return y r 4) Always use the smallest liquid line allowable to minimize refrigerant charge :3 5) Applications shaded in light gray indicate capacity multipliers between 0 90 and 0.96 which are not recommended,but are allowed `D 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop m 0 3 m 0 Refrigerant Line Size Information (con't.) JLb 13-16 SEER Single-Stage Air-Conditioners y Apply Long Line Guidelines if Equivalent Length(Feet) Allowable Allowable Linear Line Length Exceeds n Unit Size Liquid Line Suction Line Those Shown Below (Feet) <25 26-50 51-75 1 76-100 1 101-125 1 126-150 1 151-175 1 176-200 1 201-225 226-250 Size Size (-)A14 (-)A14 (-)A13 W (-)A16 Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier AtBH r FD 3/8" 3/4" 148 110 N/A 35 25/0.99 50/0.98 75.t 0:96 77/ °NI 0.95 67/0.93` "5710.92 46/0.91 3 *R", '"° ` NIRy-,' m 1/2° 3/4" 74 55 N/A 18 25/0.99 50/0.98 -75/0.96 :1007 0.95 ":'100 1,0.93` ,100/0.92 "1'00/0.91. z NIR=: - ,e NM ;_. N/Ft 4 . m 4 Ton 3/8" 7/8" 148 110 N/A 35 25/1.00 50/0.99 75/099 77/0.98 67/0.97 57/097 -46/0.96 36-/0.96 2610.95 :1510.95 0 1/2" 7/8° 74 55 N/A 18 25/100 50/0.99 75/0.99 100/0.98 100/0.97 100/0.97 100/0.96, '100./.0.96. "997 0.95 . ° 97/0.95- 3 _ _ v 3/8" 3/4" 78 55 N/A 0 25/0.99 50/0.97 75-/0'.94 ' 61 t 0.92" "4610:90 1/2" 3/4" 39 28 WA 0 25/0.99 50/097 75/0.94 100/0.92 100/0.90, 3/8" 7/8" 78 55 N/A 0 25/1.00 50/0.99 75/098 61/0.97 =46%0.46' '-7;1210.06- ' °.18`10:94 5 Ton 1/2' 7/8" 39 28 N/A 0 25/1.00 50/099 75/0.98 100/0.97 1001/0.96'-" =100/0.95 97!0.94 '9V,0.94,' -92/0,93, 89/0.92 3/8° 1 1/8° 78 55 N/A 0 25/1.01 50/ 1 01 75/1.00 61/1.00 46/0.99 32/ 0.99 18/0.99 °.N%R. 1/2° 1-1/8° 39 28 1 N/A 0 25/101 50/101 75/1.00 100/1.00 100/099 100/0.99 97/0.99 95/099 92/ 0.99 89/0 98 NOTES: 1) Do not exceed 200 ft linear line length 2) 'Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit 3)**3/4"suction line should only be used for 1 5 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return 4) Always use the smallest liquid line allowable to minimize refrigerant charge 5) Applications shaded in light gray indicate capacity multipliers between 0 90 and 0.96 which are not recommended,but are allowed 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop Refrigerant Line Size Information 13-16 SEER Single-Stage Air-Conditioners Apply Long Line Guidelines if Equivalent Length(Meters) Allowable Allowable Linear Line Length Exceeds Unit Size Liquid Line Suction Line Those Shown Below (Feet) <8 8-15 16-23 1 24-30 1 31-38 1 39-46 1 47-53 1 54-61 1 62-69 70-76 Size Size mm[in.] mm[in.] (-)A14 (-)A14 (-)A13 A/B W (-)A16 Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier 6.35[1/4] 15 88[5/8] N/A N/A N/A N/A 8/1.00 15/0.99 19/0.98 13/0.98 7/0.97 2/0.97 5.3 KW 7.94[5/16] 15 88[5/8] N/A 68 60 57 8/1.00 15/0.99 23/0.98 30/0.98 28/0.97 27/0.97 25/Q.96 ,, -2411/0.96 22/0.95 21/0.94 ; [1.5 Ton] 9.53[3/8] 15.88[5/8] 54 45 40 38 8/1.00 15/0.99 23/0.98 30/0.98 30/097 30/0.97 -30/0.96 30/0.96 30?0.95 30/0.94' **SEE 6.35[1/4] 19.05[3/4]** N/A N/A N/A N/A 8/1.00 15/100 19/099 13/0.99 7/0.99 2/0.99 NOTE 3 7.94[5/16] 19.05[3/41'- N/A 68 60 57 8/1.00 15/1.00 23/099 30/0.99 28/0.99 27/0.99 25/0.99 24/0.98 22/0.98 21/0.98 9 53[3/8] 19.05[3/4]'- 54 45 40 38 8/1.00 15/100 23/099 30/099 30/0.99 30/0.99 30/0.99 30/0.98 30/0.98 30/0.98 6 35[1/4] 15.88[5/8] N/A N/A N/A N/A 8/099 15/0.98 6/0.97 ` : :I!01/R' ':l<llfi ' '1f1R: td/R 7 94[5/16] 15.88[5/8] 74 65 59 53 8/099 15/098 23/097 27/0.96 " "23/'045 2110.94 19/,0.93 :16/0.92 14-10.91 "11 7,0 KW 9.53[3/8] 15.88[5/8] 49 43 39 36 8/099 15/098 23/097 :,_3010'96 30/A-95." '3010.94 '30/0.93 29/0.92 28/0.91, 277 0.90 [2 Ton] 6 35[1/4] 19.05[3/4] N/A N/A N/A N/A 1 8/1.00 15/1.00 6/0.99 'WR Nlf::. "- ._ ,NIR .w aWR` NIR WR' 7 94[5/16] 19.05[3/4] 74 65 59 53 8/1.00 15/1.00 1 23/0.99 27/099 23/098 21/0.98 19/098 16/0.97 14/097 .11/0.96 9 53[3/8] 19.05[3/4] 49 43 39 36 8/1.00 15/1.00 23/0.99 30/0.99 30/0.98 30/0.98 30/0.98 29/0.97 28/097 2710.96 7 94[5/16] 15.88[5/8] N/A N/A 40 34 8/0.99 15/0.98 23%0.96 ; 21/0.94, "18/0.93, 15%.0.91, _ '.11/0.90 '• ,NlR 8.8 KW 9.53[3/8] 15.88[5/8] 43 36 27 22 8/0.99 15/0.98 23/0,96- 3010-94 30/0.93' 29/0-91 • 27/0.90 : lillR'E tilfEt ..,. NnR. 12.5 Ton] 7 94[5/16] 19.05[3/4] 65 53 40 34 8/1.00 15/0.99 23/0.99 21/0.98 18/0.98 15/0.97 '111'0.96'0.96 87 0,96' ` 410,05" """N/R' 9.53[3/8] 19.05[3/4] 43 36 27 22 8/1.00 15/0.99 23/0.99 30/0.98 30/0.98 29/0.97 -2T/0.96 ' '26/'0.96 2510.95 -24-.0.95 7 94[5/16] 15.88[5/8] N/A N/A N/A N/A 8/0.99 15/0.97 '20/,0.94 151.0:92;. 15/,0.90` ._, _Pd/R.-,,; , "=.N Nlfi =:"m. ".;,'PllR . '. `"W1a' f WR 9.53[3/8] 15.88[5/8] 33 26 27 25 8/0.99 15/0.97 23/-0.94 29/-0:92' . 2710.90. ;; IUlR: MIR « • 7.94[5/16] 19.05[3/4] N/A 39 41 37 8/1.00 15/0.99 20/0.98 15/0.98 10/0.97 V0.96_ 0.96- • 10.6 KW 9 53[3/8] 19.05[3/4] 33 26 27 25 8/1.00 15/0.99 23/0.98 29/0.98 27/097 2610:96.;;"-24/0.95. , •2210.94" : Y;2010.93 19/0.93,---, [3 Ton] 12.70[1/2] 19.05[3/4] 17 13 14 12 8/1.00 15/099 23/0.98 30/098 30/097 30/0:96 3,0./,0.95_ :-.3010.94 30/0.93: 30/ .93--- 7.94[5/16] 22.23[7/8] N/A 39 41 37 8/1.00 15/1.00 20/1.00 15/0.99 10/0.99 5/0.99 °,°'.NIR} %(i;=;' - iNlR . : :° Na a 9.53[3/8] 22 23[7/8] 33 26 27 25 8/100 15/1.00 23/1.00 29/0.99 27/0.99 26/0.99 24/098 22/0.98 20/0.98 19/0.97 12.70[1/2] 22.23[7/8] 17 13 14 12 8/1.00 15/1.00 23/1.00 30/0.99 30/0.99 30/0.99 30/0.98 30/098 30/0.98 30/097 9.53[3/8] 19.05[3/4] 46 38 31 23 8/0.99 15/0.98 23/0.97 27/0.96, 2410:95; 22/,,0.94 " 26/0,62 17/0.91 16 LOM 12.3 KW 12.70[1/2] 19.05[3/4] 23 19 15 11 8/0.99 15/0.98 23/0.97 `30/0.96 '30./0.95 ' `30 1'0.94 30 7.0.92" ' 30'/0.91` 30/0:90 �.IVq0.966V ��� [3.5 Ton] 9.53[3/8] 22 23[7/8] 46 38 31 23 8/1.00 15/1.00 23/0.99 27/0.99 24/0.99 22/0.98 20/0.97 17/0.97 15-10.96 ,, 13°/12.70[1/2] 22 23[7/8] 23 19 15 11 8/1.00 15/1.00 23/0.99 30/099 30/0.99 30/0.98 30/0.97 30/0.97 30 f0.96 . 306 NOTES: D 1) Do not exceed 200 it linear line length co 2) *Do not exceed 100 it vertical separation if outdoor unit is above indoor unit Mn 3)'*3/4°suction line should only be used for 15 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return co w r- 4) Always use the smallest liquid line allowable to minimize refrigerant charge � 5) Applications shaded in light gray indicate capacity multipliers between 0 90 and 0 96 which are not recommended,but are allowed. `D 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop 5 0 3 w 0 Refrigerant Line Size Information (con't.) JL6 13-16 SEER Single-Stage Air-Conditioners D Apply Long Line Guidelines if Equivalent Length(Meters) Allowable Allowable Linear Line Length Exceeds n Unit Size Liquid Line Suction Line Those Shown Below (Feet) <25 26-50 1 51-75 1 76-100 1 101-125 1 126-150 1 151-175 1 176-200 201-225 226-250 Size Size (-)A14 (-)A14 C (-)A13 A/BW (-)Al6 Maximum Vertical Rise(Outdoor Unit Below Indoor Unit)*/Capacity Multiplier m r 9.53[3/8] 19.05[3/4] 45 34 N/A 11 8/099 15/0.98 --,23.-t-0,96 24[0.95` -201/0.W', 17/0.92 14 t 0,91' Nlft:'=; N%R`-,' .N/R' m' 14.1 KW 12.7[1/2] 19.05[3/4] 23 17 N/A 5 8/0.99 15/0.98 ;23 1:0:96-� 30!0.95 3010:93 30/0.92 30 5.91"7CD Nl#Z r; [4 Ton] 9.53[3/8] 22.23[7/8] 45 34 N/A 11 8/1.00 15/0.99 23/0.99 24/0.98 20/0.97 17/0.97 14/0.96 11/0.96 810.95 6/0_.95 0 12 7[1/2] 22 23[7/8] 23 17 N/A 5 8/1.00 15/099 23/099 30/0.98 30/0.97 30/0.97 30/0.916 3010.96 3010.95 307 0.95 9 53[3/8] 19.05[314] 24 17 N/A 0 8/0.99 15/0.97 23%0.94 19101.921-• 14/0.-90 .`,`=3N/R, N1R>; NIR' rlD/R a N/R>" 0 12 7[1/2] 19.05[3/4] 12 8 N/A 0 8/0.99 15/0.97 23't0.94` - ' 3010.92- 17.6 0"/,0.9217.6 KW 9 53[3/8] 22 23[7/8] 24 17 N/A 0 8/1.00 15/0 99' 23/0.98 19/097 14/6.96 . 10/0.95- 5[0.94 ._ i0/FY';'; : ,,;NtR" [5 Ton] 12.7[1/2] 22.23[7/8] 12 8 N/A 0 8/1.00 15/0.99 23/098 30/0.97 30/0:96 r 3010.95 ` 30[0.94 29/,,9.94 28 1-0.93' 2710.92 9 53[3/8] 28 58[1-1/8] 24 17 N/A 0 8/101 15/1.01 23/1.00 19/1.00 14/0.99 10/ 099 5/099 12.7[1/2] 28 58[1-1/8] 12 8 N/A 0 8/1.01 15/101 1 23/100 30/1.00 30/0 99 30/099 30/0.99 29/0.99 28/ 0.99 27/0 98 NOTES: 1) Do not exceed 200 ft linear line length 2) *Do not exceed 100 ft vertical separation if outdoor unit is above indoor unit 3)"3/4'suction line should only be used for 15 ton systems if outdoor unit is below or at same level as indoor to assure proper oil return 4) Always use the smallest liquid line allowable to minimize refrigerant charge 5) Applications shaded in light gray indicate capacity multipliers between 0 90 and 0.96 which are not recommended,but are allowed. 6) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop. IT s -on Air Performance Data ' 'a RA16 Series Performance Data @ AHRI Standard Conditions - Cooling Designated Tested Combination(DTC) Outdoor Unit Indoor Coil Total Capacity Net Sensible Net Latent SEER EER Indoor CFM[L/sl BTU/H[kW1 BTU/H[kWl BTU/H 1kW1 RA1618AJ1 RCF2417STA 18000 [5.3] 13500 [4.0] 4500[1 3] 1450 12.20 600[283.2] RA1624AJ1 RCF2417STA 24000 [7.0] 17500 [5.1] 6500[1.9] 14.50 12.20 800[377.6] RA1630AJ1 RCF3617STA 28400 [8.31 21600 [6.31 6800[2.01 14.50 12.20 1025[483 71 RA1636AJ1 RCF3617STA 34800[10.21 24700 [7.2] 10100[3.01 14.50 12.20 1000[471 9] RA1636BJ1 RCF3617STA 35800[10.5] 25500 [7.5] 10300[3.0] 14.50 12.20 1100[519 1] RA1642AJ1 RCF4821STA 41000[12 0] 30400 [8.9] 10600[3.1] 14.50 12.20 1425[672 51 RA1648AJ1 RCF4821 MTA 46000[13.5] 33200 [9.71 12800[3 8] 15.10 12.50 1600[755 1 1 RA1660AJ1 RCF6024STA 56500[16.6] t 41200[12.11 15300[4.51 15.10 1 12.50 1525 Air Handler Outdoor Total Capacity Net Sensible Net Latent Indoor CFM Unit Air Handler BTU/H[kW1 BTU/H[kW] BTU/H[kW] SEER EER [L/sl RA1618AJ1 RHiT2417STAN 18000 [5 3] 13500 [4.0] 4500[1.3] 16.00 13.00 600[283 2] RA1624AJ1 RHIT2417STAN 24000 [7.0] 17500 [5.11 6500[1.9] 16.00 13.00 800[377.6] RA1630AJ1 RHiT3617STAN 29000 [8.5] 21600 [6.31 6800[2.0] 1600 13.00 1000[471.9] RA1636AJ1 RHiT3621MTAN 35400[10.31 24700 [7.21 10100[3.01 16.00 13.00 1000[471.9] RA1642AJ1 RHiT4821STAN 41500[12 2] 33200 [9.71 12800[3.81 16.00 13.00 1400[660 7] RA1648AJ1 RMT4821STAN 42000[12.2] 41200[12.1] 15300[4.51 1600 13.00 1400[660.7] RA1660AJ1 RHiT6021STAN 56000[16.4] 41200[12.11 15300[4.5] 15.50 12.50 1575[755.2] Note:Additional ratings and system match ups can be accessed on MyRheem.com at.https•//my rheem.com/static/private/ahriresidential.html Additional ratings and system match ups and downloadable ratings certdicates can be accessed from the AHRI website:www.ahndirectory org [ ]Designates Metric Conversions INTEGRATED • COMFORT 17 r Guide Specifications -a Air I RA16 Series GUIDE SPECIFICATIONS General AIR-COOLED,SPLIT-SYSTEM AIR CONDITIONER System Description RA16 Outdoor-mounted, air-cooled, split-system air conditioner com- 1-1/2 TO 5 NOMINAL TONS posite base pan unit suitable for ground or rooftop installation Fans Unit consists of a hermetic compressor, an air-cooled coil, pro- — Condenser fan will be direct-drive propeller type, discharging peller-type condenser fan, suction and legend line service valve, air upward. and a control box. Unit will discharge supply air upward as shown — Condenser fan motors will be totally enclosed, 1-phase type on contract drawings. Unit will be used in a refrigeration circuit to with class B insulation and permanently lubricated bearings. match up to a coil unit. Shafts will be corrosion resistant. Quality Assurance — Fan blades will be statically and dynamically balanced. — Unit will be rated in accordance with the latest edition of AHRI — Condenser fan openings will be equipped with coated steel Standard 210. wire safety guards. — Unit will be certified for capacity and efficiency, and listed in Compressor the latest AHRI directory. — Compressor will be hermetically sealed. — Unit construction will comply with latest edition of ANSI/ — Compressor will be mounted on rubber vibration isolators. ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and Condenser Coil will carry the UL label of approval. Unit will have c-UL-us — Condenser coil will be air cooled. approval. — Coil will be constructed of aluminum fins mechanically bonded — Unit cabinet will be capable of withstanding ASTM 13117 1000- to copper tubes. hr salt spray test. Refrigeration Components — Air-cooled condenser coils will be leak tested at 150 psig and — Refrigeration circuit components will include liquid-line shutoff pressure tested at 550 psig. valve with sweat connections, vapor-line shutoff valve with — Unit constructed in IS09001 approved facility. sweat connections, system charge of R-410A refrigerant, and Delivery,Storage,and Handling compressor oil. — Unit will be shipped as single package only and is stored and — Unit will be equipped with filter drier for R-41 OA refrigerant for handled per unit manufacturer's recommendations. field installation. Warranty(for inclusion by specifying engineer) — U.S. and Operating Characteristics Canada only. — The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The power consumption Products at full load will not exceed kW. — Combination of the unit and the evaporator or fan coil unit will Equipment have a total net cooling capacity of Btuh or greater at Factory assembled, single piece, air-cooled air conditioner unit. conditions of CFM entering air temperature at the evap- Contained within the unit enclosure is all factory wiring, piping, orator at °F/°C wet bulb and 'FPC dry bulb, and controls, compressor, refrigerant charge R-41 OA, and special fea- air entering the unit at °F/°C. tures required prior to field start-up. — The system will have a SEER of Btuh/watt or greater at Unit Cabinet DOE conditions. — Unit cabinet will be constructed of galvanized steel, bonder- Electrical Requirements ized, and coated with a powder coat paint. — Nominal unit electrical characteristics will be v, single — All units constructed with louver coil protection and corner post. phase, 60 hz.The unit will be capable of satisfactory operation Louver can be removed by removing one fastener per louver within voltage limits of v to V. panel. — Nominal unit electrical characteristics will be v, three phase, 60 hz.The unit will be capable of satisfactory operation within voltage limits of v to V. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. ''' Air I Limited Warranty 0 RAI 6 Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Conditional Parts which fails in normal use and service within the applicable (Registration Required)...............................Ten(10)Years period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties,including applicable terms and conditions,contact your local contractor or the Manufacturer for a copy of the product warranty certificate. INTEGRATED • • •- The new degree of comfort:" _ In keeping with its policy of continuous progress and product improvement,Rheem reserves the right to make changes without notice Rheem Heating,Cooling&Water Heating 5600 Old Greenwood Road Rheem Canada Ltd./Ltee • 125 Edgeware Road,Unit 1 Fort Smith,Arkansas 72908 www.rheem corn Brampton,Ontario • L6Y OP5 a INTEGRATED HOME COMFORT PRINTED IN U S A 8119 OG FORM NO A11-222 REV 8 3!3/2020 Rheem RHIT3617STANAA-3 Ton,R410A,Single Stage,Aluminum Air Handler,Constant Torque Motor,115V,1 Ph,60 Hz---1399041970758 w „�.,�• an � � ,Y I �. ? •-kik,. �. a{>'" �'��� i jF zt- 44 View full-size in new tab Rheem RH1T3617STA-NAA - 3 Ton, R410A, Single Stage, Aluminum Air Handler, Constant Torque Motor, 115V, 1 Ph, 60 Hz Item: RH1T3617STANAA MFR: RH1T3617STANAA i E i What's the price? Your Order Templates Sign in or register for s Save products for later, or create order templates to quickly re-buy items f pricing. g for routine jobs. 3 OuantitY Add To Order Template i Add to Cart Inventory At Nearby Branches i j North Carolina i 0 Charlotte#704 i 0 Hickory#703 0 Raleigh#708 i https://www gemaire.com/rheem-rhIt3617stanaa-3-ton-r410a-single-stage-aluminum-air-handler-constant-torque-motor-115v-1-ph-60-hz-rhl t3617stanaa#tab-specific... 1/3 3/3/2020 Rheem RH1T3617STANAA-3 Ton,R410A,Single Stage,Aluminum Air Handler,Constant Torque Motor,115V,1 Ph,60 Hz---1399041970758 0 Wilmington #706 0 Winston-Salem#701 Virginia 5 Chesapeake#713 1 Newport News#714 i 5 Richmond #711 } 1 Roanoke#712 All Branches 30 Description Specifications Name Rheem RH1T3617STANAA-3 Ton,R410A,Single Stage,Aluminum Air Handler,Constant Torque Motor, 1115V,1 Ph,60 Hz Gemaire Item Number RH1T3617STANAA 'Manufacturer Product RH1T3617STANAA ; Number ` SKU-PIM Number 1399041970758 q ' ERP Number 1362233 Unit of Measure ' EA weight �96.0 Pounds(Lb) Length 21.7 Inches(In) -- - ----- -- --- - ---- - - -- Width 117.5 Inches(In) 1 Height E 42.5 Inches(In) Country of Origin c MEX Brand Rheem i Equipment Type Heat Pump Tonnage [3 Stage Single SEER 116 t Refrigerant R-410a CFM 11000-1200 Cooling Capacity 130000-36000 I i https//www.gemaire com/rheem-rhlt3617stanaa-3-ton-r410a-single-stage-aluminum-air-handler-constant-torque-motor-115v-1-ph-60-hz-rhlt3617stanaa#tab-specific 2/3 I 3/3/2020 Rheem RH 1T3617STANAA-3 Ton,R410A,Single Stage,Aluminum Air Handler,Constant Torque Motor,115V,1 Ph,60 Hz---1399041970758 Heating Capacity 30000-36000 1 Air Flow Convertible Voltage 115 VAC Phase — Single Cycle/Hertz 160 Hz Circuit Breaker-Max 15 Amps Minimum Circuit Amps 9 Maximum Fuse Size...—_.__.15.______..._...—._...._.,. __. •_.. .._..._—..,........_ .,.,__.-_._..�.._______. �_�.. .__�_.•M Blower Motor HP 1/2 HP � Blower Motor RPM 300-1100 Y+` Filter Size— — External filter rack can accommodate 16"x 20"x 1"or 2 Drain Connection Size 3/4" Suction Line Fitting Sweat ------`---------- ---- -'-_----- ---- Suction Line Size(OD) 3/4" Liquid Line Fitting Sweat Liquid Line Size(OD) 3/8" Certifications AHRI,ISO 9001:2008 Color Rheem Warm Gray I Warranty Offered Yes Energy Star Rated No UL Listed Yes Product Family RH1T Drain Connections 3 _ _ _.., —.__ ._. _ -_. ___..__• Tier High Efficiency GEM-Case Ouantity Matched Systems Documentation AHRI Matchups Parts List https://www.gemaire.com/rheem-rh 1 t3617stanaa-3-ton-r410a-single-stage-aluminum-air-handler-constant-torque-motor-115v-1-ph-60-hz-rh 1 t3617stanaa#tab-specific.. 3/3 Q — i 2-3. Wall mounted type Model name RIWHD7AVFJ ',RlWN09AVFJ RIUUH12AVFJ RtI4WH15%1VFJ • • Power supply 208/230 V–60 Hz ~ Available voltage range 187-264 V Capacity Btu/h class 7,000 9,000 12,000 14,000 Input power W 15 17 22 28 Running current A 013 015 019 025 HIGH 330(560) 353(600) 388(660) 430(730) Cooling MED 294(500) 306(520) 330(560) 353(600) Us LOW 253(430) 253(430) 265(450) 312(530) QUIET s 182(310) 182(310) 182(310) 212(360) Airflow rate HIGH CFM(m/h) 330(560) 353(600) 388(660) 430(730) Fan MED 294(500) 306(520) 330(560) 362(615) Heating LOW 253(430) 253(430) 277(470) 330(560) QUIET 194(330) 194(330) 194(330) 221(375) Type x Q'ty Cross flow fan x 1 Motor output W 30 HIGH 36 37 40 42 Cooling MED 32 33 36 38 LOW 29 29 30 33 Sound pressure level` HIGH QUIET d8(A) 21 21 21 25 36 37 40 42 Heating MED 32 33 36 38 LOW 29 29 31 35 QUIET 22 22 22 27 Dimensions(H x W x D) in(mm) Main 12-5/8 x 24-13/16 x 13/16(320 x 630 x 20) Sub 3-5116 x 24-13/16 x 1/2(84 x 630 x 13 3) Fin pitch FPI Main 23,Sub 18 Heat exchanger type Rows x Stages 9 Main 2 x 20,Sub 1 x 4 Pipe type Copper tube Fin type Aluminum Material Polystyrene Enclosure Color White (Approximate color of Munsell N 9 25/) Dimensions Net 10-5/8 x 34-114 x 8-1/16(270 x 870 x 204) in(mm) (H x W x D) Gross 10-518 x 36-7/16 x 13-1/4(270 x 925 x 336) Weight Net Ib(kg) 19(8 5) Gross 24(11) ( ) Connection Size Gas Liquid in(mm) 0318(09 52)01/4 06 35 0112(012 70) pipe Method Flare Drain hose Material PP+LLDPE Size in(mm) 0 9116(1 D),0 5/8 to 0 11/16(0 D)[0 13 8(1 D),015 8 to 0 16 7(0 D)] Cooling °F(°C) 64 to 90(18 to 32) Operation range I %RH 80 or less Heating °F(°C) 60 to 86(16 to 30) Remote controller type Wireless(Wired[option]) NOTES: The protective function might work when using it outside the operation range 'Sound pressure level – Measured values in manufacturer's anechoic chamber – Because of the surrounding sound environment,the sound levels measured in actual installation conditions might be higher than the specified values here t , 3-3. Wall mounted type • ■ Models: RIWH07AVFJ, RIWH09AVFJ, RIWH12AVFJ, and RI- WH15AVFJ Unit: in (mm) 34-1/4 870 8-1/16 204 ' o ti N ap O i [34-1/4(870)] M 16-3/4(426) 17-1/2(444) 12-3/16(310) 11-5/8(295) 7 1 1 1. Outline of unit N o p 0 0 0 0 0 O v ^ N W v o «0 0 0 o y o O ° oD zp - F IW 2-9/16 65 6-1/2(165) 5-11/16(144 2-9/16 65 for pipe inlet for pipe inlet 7(178) 9-3/16(233) 12-5/8(321) 12-3/8(315) 1. Specifications Type tnverter'6eat pump Model name ROMH24AF•XZJ Power source 10 208/230 V 60 Hz Available voltage range 187-264V Connectable indoor unit Number 2 to 3 Total capacity range 14,000 to 21,000 Btu/h Non-duct Combination of indoor unit RIWH09AVFJ RIDHI Duct uct x 2 Mix +RIWH07AVFJ x 2 Rated Btu/h 22,000 Cooling kW 642 Min—Max Btu/h 6,100-27,000 6,100-25,000 6,100-26,000 Capacity kW 1 B-79 18-73 18-76 Rated Btu/h 24,000 Heating kW 702 Min—Max Btu/h 6,800-29,800 6,800-27,400 6,800-28,600 kW 20-87 20-80 20-84 Cooling Rated 176 208 190 Input ower Max kW 260 284 272 P p Rated 173 205 188 Heating Max 293 Current Cooling Rated q 77 91 84 Heating 76 90 83 0 EER Cooling Rated Btu/W 1250 1060 1155 SEER*t Cooling 1800 1550 1675 COP Heating Rated W/W 405 343 374 HSPF*1 Heating 950 900 925 Starling current A 90 Maximum operating current*2 A 137 Type x Q'ty Propeller x 1 Airflow rate Cooling CFM(m3/h) 1,942(3,300) Fan Heating 1,942(3,300) Motor Type x Quantity DC motor x 1 Output W 100 Sound pressure level Cooling Rated dB(A) 51 Heating 52 Dimension(H x W x D) in(mm) 26-7/16 x 35-7116 x 1-7/16(672 x 900 x 36 38) Fin pitch FPI 18 Heat exchanger Rows x Stages 2 x 32 Pipe type(Material) Grooved H-pin(Copper) Fin Type(Material) Corrugate(Aluminum) Surface treatment Corrosion resistance(Blue Fin) Compressor Type x Quantity DC twin rotary x 1 p1 Motor output W 1,100 Refrigerant Type R41 OA Charge Ib(g) 4 Ib 14 oz(2,200) Refrigerant oil Type POE Amount in3(cm3) 39 7(650) Material Painted galvanized steel Enclosure Color Beige (Approximate color of Munsell 10YR 7 5/10 NN) Dimensions Net (H x W x D) in(mm) 27-9/16 x 35-7/16 x 13(700 x 900 x 330) Gross 34-1/16 x 41-5116 x 17-1/2(865 x 1,050 x 445) Net 124(56) Weight Gross Ib(kg) 141(64) Size LE'd in(mm) 0114(06 35)x 3 Gas 03/8(09 52)x 2+0112(012 7)x 1 Method Flare Pre-charge length(Total) 98(30) Max length(Total) 164(50) Connection pipe Max length(Each) 82(25) Min length(Total) ft(m) 49(15) Min length(Each) 16(5) Max height difference between outdoor unit and each 49(15) indoor units Max height difference between indoor units 33(10) Operation range Cooling *F(,C) 14 to 115(A 0 to 46) Heating 15 to 75(-15 to 24) NOTES: Specifications are based on the following conditions - Power source of specifications 230 V - Pipe length 24 6 ft(7 5 m),Height difference 0 ft(0 m)[Outdoor unit—Indoor unit] - Cooling Indoor temperature of 80°FDB(26 7°CDB)/67*FWB(19 4*CWB),and outdoor temperature of 95°FDB(35*CDB)/75*FWB(23 9'CWB) - Heating Indoor temperature of 70°FDB(21 1*CDB)/60*FWB(15 6*CWB),and outdoor temperature of 47°FDB(8 3*CDB)143'FWB(61'CWB) - *1 Test conditions are based on AHRI 2101240 - *2 The maximum current is the maximum value when the operated within the operation range For other combination,refer to the combination table The protective function might work when using it outside the operation range 2. Dimensions 2-1. Model: ROMH24AFXZJ Unit: in(mm) Top view 1-9/16 1-1/4 1/2 35-7/16(900) 40 31 13 330 12 • o o co rn n N O 0 N O `O 0 m 15-3/4(400) Front view Side view 25-9/16(650) QAirflow /u •IMII zt N N•_•��`.. aN0 o a Y ' 1/2 � Bottom view 4 °12 (12) 6 Drain cap mounting places Drain pipe mounting places 141