Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
44460-Z
f S� FF Ot Town of Southold 7/14/2020 a P.O.Box 1179 0 W 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41252 Date: 7/14/2020 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1045 Dean Dr, Cutchogue SCTM#: 473889 Sec/Block/Lot: 116.-5-9 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 11/19/2019 pursuant to which Building Permit No. 44460 dated 11/25/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as applied for. The certificate is issued to Janusz,Robert&DeBlasio-Janusz,Patricia of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 44460 7/2/2020 PLUMBERS CERTIFICATION DATED Authorize Signature o�gUfF.LlrTOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy • o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 44460 Date: 11/25/2019 Permission is hereby granted to: Janusz, Robert & Janusz, Robert 18 Hartley Ln Basking Ridge, NJ 07920 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 1045 Dean Dr, Cutchogue SCTM # 473889 Sec/Block/Lot# 116.-5-9 Pursuant to application dated 11/19/2019 and approved by the Building Inspector. To expire on 5/26/2021. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 B pector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957)non-conforming uses, or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. // _L1_1 9 New Construction: Old or Pre-existing Building: X (check one) Location of Property: 1045 Dean Drive Cutchogue House No. Street Hamlet Owner or Owners of Property: Robert Janusz Suffolk County Tax Map No 1000, Section 116 Block 5 Lot 9 Subdivision f Filed Map. Lot: Permit No. —I 0 Date of Permit. Applicant: GreenLogic LLC Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: X (check one) Fee Submitted: $ 50 pplicant Signature Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) I, Robert Janusz residing at �0�{S bfaK �R, C1,4CAv71ke-A1--Y- (Print property owner's name) (Mailing Address) � do hereby authorize GreenLogic LLC (Agent) to apply on my behalf to the Southold Building Department. � /0/3/ (Owner's Signa re (Date) 7R06e(V- t-jC(YI"Z-- - (Print Owner's Name) CONSENT TO INSPECTION Robert Janusz ,the undersigned, do(es)hereby state: Owner(s)Name(s) That the undersigned(is) (are)the owner(s) of the premises in the Town of Southold, located at 1045 Dean Drive, Cutchogue, NY 11935 , which is shown and designated on the Suffolk County Tax Map as District 1000, Section 116 , Block 5 , Lot 9 That the undersigned(has) (have) filed, or cause to be filed, an application in the Southold Town Building Inspector's Office for the following: Roof mounted solar electric system That the undersigned do(es)hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon, to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws, ordinances,rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections, do(es) so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances,rules or regulations of the Town of Southold. Dated: 2 (Print Name) (Signature) (Print Name) rg so Town Hall Annex ® Telephone(631)765-1802 54375 Main Road , - W Fax(631)765-9502 P.O. ox 117 Southoldd,,NY 11971-0959 x w sean.devlinl-town.southold.ny.us .� � "- "'� �® "®U ,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Robert Janusz Address- 1045 Dean Dr city:Cutchogue st- NY zip: 11935 Building Permit#: 44460 Section 1 16 Block: 5 Lot 9 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Green Logic LLC License No- 43858ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Solar X Commerical Outdoor X 1 st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment: 13,080kW Roof Mounted PV Solar System w/40 Sun Power SPR-E20-327-E-AC Panels w/ Micro Inverters Notes- Solar Inspector Signature: Date: July 2, 2020 S.Devlin-Cert Electrical Compliance Form As OF SOUlyolo 1 O f V L4 g TOWN OF SOUTHOLD BUILDING DEPT. cou765-1802 INSPECTI-ON , [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND j ] INSULATIOWCAULKING- - [ ] FRAMING /STRAPPING [ ] FINAL T ] FIREPLACE & CHIMNEY'- [! ] ` FIRE SAFETY INSPECTION y' " [ '] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PEN ETR [ ] ELECTRICAL(ROUGH) [ ELECTRICAL�(FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: ooc� r c,&o DATE Z INSPECTOR L J A M E S J. S TOUT A R C H I T E C T & Assoc . 2 G REG L ANE EAST NORTHPORT N. Y. 631 - 8 58 9388 Post Installation Letter December 27, 2019 RE: Janusz Residence 1045 Dean Drive Cutchogue, NY 11943 To Whom It May Concern: This letter is to confirm that as of this date December 27, 2019, I, James J Stout, NYS license 021633 have personally inspected the placement and installation of the roof top solar panels at the above listed address.All of the solar panels have been installed as per manufacturer's guidelines and specifications. The racking system design and installation complies with the 2017 NYSRC and 2017 NYSUCS building code and all related provisions.The installation of panels was done as per plan. Thank you for your cooperation in this matter, James J, Stout Architect FEB - 5 2020 T 021633 �0�k- F OF NES � i SER SOURCE 1 y N sir 1 r 3L 40 W17►�M �.. nr .'.iii.... r FIELD INSPECTION REPORT I DATE COMMENTS FOUNDATION(1ST) H ------------------------------------- FOUNDATION (2ND) z ROUGH FRAMING& y PLUMBING 6� . 1 - � r INSULATION PER N.Y. y STATE ENERGY CODE FINAL ADDITIONAL CO NTS 5Ro f-cr-ld6,4 1 C2 0 1114:zl rn 0 z H x e TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTIA&D,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey Southoldtownny.gov PERMIT NO. _ l Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined I C ,20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved ,20 1 Mail to: Green Logic LLC Disapproved a/c 97 North Sea Road, Southampton, NY 11968 Phone: 631-771-5152 Expiration 1-2 Building Inspector APPLICATION FOR BUILDING PERMIT Date C ( �� , 20J INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may'authorize,in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. GreenLogic LLC (Signature of applicant or name,if a corporation) 97 North Sea Road, Southampton, NY 11968 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Contractor Name of owner of premises Robert Janusz (As on the tax roll or latest deed) If applicant is a corporation, sign tore of duly authorized officer Nesim Albukrek, President (Name and title of corporateOfficer) Builders License No. 40227-H Plumbers License No. N/A Electricians License No. 43858-ME Other Trade's License No. N/A 1. Location of land on which proposed work will be done: 1045 Dean Drive Cutchogue House Number Street Hamlet County Tax Map No. 1000 Section 116 Block 5 Lot 9 . Subdivision Filed Map No. Lot 2. State!ekisting use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single family dwelling b. Intended use and occupancy Single family dwelling 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work Roof mounted solar electric system (Description) 4. Estimated Cost $42,996 Fee $200 (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase 8/2017 Name of Former Owner Robert Taylor 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO X 13. Will lot be re-graded?YES NO X Will excess fill be removed from premises? YES NO X 1045 Dean Drive 14. Names of Owner of premises Robert Janusz Address Cutchogue, NY 11935 phone No. 631-655-9596 Name of Architect james J. Stout Address 2 Greg Ln, E. Northport Phone No 631-858-9388 Name of Contractor GreenLogic LLC Address97 North Sea Road Phone No. 631-771-5152 Southampton, NY 11968 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO X * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO X * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide sprvey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO X * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk Nesim Albukrek being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of NO L&Y]� 20 1 R BARBARA A CASCIOTTA Notary b0�1-CA4894969 York Notary Public Qualified in Suffolk Coun Signature of A licant Commission Expires Mav 11. 202.3 PP Scott A. Russell SUPERVISOR � MANAGEMENT SOUTHOLD TOWN HALL-P.O.Box 1179 O 53095 Main Roa&-SOUTHOLD,NEW YORK 12971 Town of Southold CHAPTER 236 - STGRMWATER MANAGEMENT WORK SHEET (TO BE COMPLETED BY TIME APPLICANT ) r DOFS THIS PROJECT INVOLVE ANY OF 'I HL- FOLIDIVIING..._._ P.M...� (CHECK-ALL THAT APPLY) ;Yes No i= ❑� A. Clearing, grubbing, grading or stripping of land -which affects more than,5,000 square feet of ground surface. ❑0 B.. Excavation or f illing involving `more than 200 cubic yards of material within any parcel or any contiguous area, t ❑ x® C. Site preparation on slopes which exceed 10 feet vertical rise to l 100 feet of horizontal distance. ❑ D. Site preparation within 100"feet of wetlands, beach, bluff or coastal erosion hazard area. ®Q E. Site preparation within the one-hundred-year f loodplain as depicted on FIRM-Map of any watercourse. F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater- Management Control plan was received by the Town and the proposal includes in-bind replacement of impervious surfaces. If you.answered-NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan. and a completed Check List Form,to the Building Department with your Building Permit Application. S.C.T.M. �: 1000 Date APPLICANT. #Propert} Owner.Design Prdfe.sionat.Agent,Contractor,Other} # DL<u in ' NAME. GreenLoaic LLC (Nesim Albukra 1 J 116 5 9 11/4/2019 N, Section Block Lot ' -r Ft)k BUILDING DEPARTMENT USE ONLY Qmtact.tnromtation. 61771-5152 Reviewed BY: e� — - - — — — — — — — — — — — — — — - �, Date: Property Address,/Locatiori of C011-ArUCtrOD Work: _ — -- -— — — — — — i ! i Approved for processing Building Permit. 1045 Dean Drive € ® Stormk ater Management Control Plan Not Required, € Cutchogue, NY 11935 !- — — — — — — — — — — — — — — — — — ? III StormNvater Management Control Plan is Required. (Forward to Engineering Department for Review.) FORM * SMCP-:COS MAY 2014 rFttl �,ell. , BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 ' • Southold, New York 11971-0959 Q� Telephone (631) 765-1802 - FAX (631) 765-9502 roper.richerttt iMn,southold.riy.vas APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Barbara Casciotta Date: 11/4/19 Company Name: GreenLogic LLC - - Name: Robert Skypala License No.: 43858-ME email: AM@Greenlogic.com Address: 97 North Sea Road, Southampton, NY 11968 Phone No.: 631-771-5152 JOB SITE INFORMATION: (All Information Required) c- Name: Robert Janusz Address: 1945 Dean Drive, Cutcho ue, NY 11935_ _ Cross Street: Phone No.: 631-656-9596 Bldg.Permit M email: Tax Map District: 1000 Section: 116 ,Block: 5 Lot:_ 9 BRIEF DESCRIPTION OF WORK(Please Print Clearly) Roof mounted solar electric system (40) SunPower SPR-E20-327-E-AC panels with mircro inverters Circle All That Apply: Is job ready for inspection?: YES /E Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) SerVice-Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead #Underground Laterals y 1 2 H Frame Pole Work done_on Service? Y N Additional Information: PAYMENT DUE WITHAPPLICATION 82-Request for Inspecdon Form As 3 GREENLOGICO ENERGY November 5, 2019 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Please find attached a building permit application on behalf of the Robert Janusz who has engaged us to install a roof mounted solar photovoltaic(PV) electric system located at 1045 Dean Drive,Cutchogue, NY. In connection with this application, please find attached: • Building Permit application • Owner Authorization • Consent to Inspection • A Storm Water Assessment Run-off Form a • Certificate of Occupancy Application f} NOV 18 2019 • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Maste i Electrician's License • Check for$200($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, '3wdk ca e,w&*a Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 ext. 117 GREENLOGIC LLC - www.GreenLogic.com Tel. 631.771.5152 Fax: 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S. Service Rd.,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 t, �G,REENLOGIC° ENERGY January 31, 2020 The Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Re: Building Permit No.44460 Robert Janusz 1045 Dean Drive, Cutchogue To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced address. Can you please close the building permit and send the Certificate of Occupancy? Please let me know if you have any questions about the installation. Sincerely, 53av&ua ea6cu+.ttac Barbara Casciotta FEB - 5 2020 Account Manager Barbara@Greenlogic.com - .. 631-771-5152 Ext. 117 GREENLOGIC LLC -www.GreenLogic.com Tel: 631 771 5152 Fax- 631.771 5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S Service Rd.,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 Lor s SURVEY OF PROPERTY N DWELLING FE DTN PUBLIC WA1EREL Vol,, EL AT CUTCHOGUE '3ppp TOWN OF SOUTHOLD - µ PL � FE OBN SUFFOLK COUNTY, N.Y. - N'1CS�.Zp E 1000-116-05-09 EL 59*' LOT 6 N/O/F SCALE. 1'30' ZIMMER DWELLING •APRIL 13, 2018 PUBLIC WATER rn TEST HOLE DATA McDONALD GEOSCIENCE 03/08/2018 rn EL a1' BROWN LOAM OL 3 % —AREA OJ05 POOLS BROWN SILTY SAND SM �; I �� — _8.— UP BROWN SILT ML 4'PALE BROWN RNE TO COARSE SAND SW 1 I / — EL.2.3' 58, 1 \ I i z�9 \ 1 1 DECK \ \\\I 1 caNDe DSD ��\ \ 1 ve 2 w- \\11 1 \CONC u 10 364 65, \\ \ 1 1 > \ WATER/N PALE BROWN RNE SAND SP \ 1 \ e all lNDusE \ N/O/F t3 DORANN K SHEEHAN 13, LOT 7 \I 1 CE f- O 6 A m \ j RESIDENTIAL TRUST VACANT 11 1 / a. DWELLING NOTE• WATER ENCOUNTERED 5.8" \\11 1 �f�' `—App I PUBLIC WATER BELOW SURFACE \\ 1 7 I 5\\ I o;, a-,33 N ,6s i I m xDe 2ND SY I KEY \. ,. \ UPPER FRONT Q = REBAR , DECK I DEC ® = WELL = STAKE7H I = TEST HOLE EL 75• - 0 = PIPE -'1 � --------5' I F m , ■ = MONUMENT o 1 �� METER �9�00W = U77LITY POLE o �— coNc cu "� CNF \ m0E Of PAVEM�501� EL 7 Y VD l ELEVATIONS REFERENCE NA88 0 � EL 6 7 NE r 1 LOT NUMBERS ARE REFERENCED TO SUBDIVISION SUFFOLK COUNTY ARK ON AUGE1L,19 OFFICE MAP DEAN DATER IN SHEET) EL 66' ( us 1 l ANY AL7ERA770N OR ADD177ON TO THIS SURVEY/S A WOLA77ON OF S. 'C. NO. 49618 SEC77ON 7209OF THE NEW YORK STATE EDUC4770N LAW EXCEPT AS _ ` PECON/C SURVEYORS, P.C. PER SEC77ON 7209—SUBDIVISION 2 ALL CERTIRCA770NS HEREON ARE VAUD FOR THIS MAP AND COPIES]HEREOF ONLY IF SAID MAP (631) 765-5020 FAX(631) 765-1797 OR COPIES BEAR THE IMPRESSED SEAL OF 7HE SURVEYOR WHOSE P.O. BOX 909 SIGNATURE APPEARS HEREON. _IC WA7� PUBLIC WATER AREA= 26,565 SQ. FT. 1 1230 TRAVELER STREET PUBLIC WATER \ SOUTHOLD, MY 11971 F18-112 DATE(MM/DD/YYYY) AC40R ►' CERTIFICATE OF LIABILITY INSURANCE �.._ 01/31/2019 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: if the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Brookhaven Agency,Inc. laic,NoPHONE 631 941-4113 Fax 631 941-0405 128 Old Town Road,Suite C E-MAIL . CustomerService@ brookhavena enc .com P.O.BOX 850 INSURERS AFFORDING COVERAGE NAIC# East Setauket NY 11733 INSURER A: Southwest Marine&General Insurance Co. INSURED INSURER B: Merchants Preferred Insurance Co. GreenLogic,LLC INSURER C: First Rehab Life Insurance Co. 97 North Sea Rd,Suite 3 INSURER D: National Liability&Fire Insurance Co. Southampton NY 11968 INSURER E. AGCS Marine Insurance Co. INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER,DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS rA TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFFM YM POLICY EXP LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 CLAIMS-MADE �OCCUR DAMAGEPREMISES(Ea—nurron—) $100,000 X Contractual Liability X X OL201900012922 01/31/2019 01/31/2020 MED EXP(Any oneperson) $5,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $2,000,000 POLICY PRO- JECT LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT(Ea amdent)_ $1,000,000 B X ANY AUTO BODILY INJURY(Per person) $ OWNEDSCHEDULED X X CAP1043565 08/11/2018 08/11/2019 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS X HIRED X NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY X UMBRELLA LIABX OCCUR EACH OCCURRENCE $1,000,000 A EXCESS LIAB CLAIMS-MADE X X UM201900007751 01/31/2019 01/31/2020 AGGREGATE $1,000,000 DED RETENTION 0 $ WORKERS COMPENSATION X PER OTH- AND EMPLOYERS'LIABILITY D ANY OFFICER/MEMBER EXCLUDED?XECUTIVE YIN N/A V9WC857891 06115/2018 06/15/2019 E L EACH ACCIDENT $1,000,000 (Mandatory in NH) E L DISEASE-EA EMPLOYEE $1,000,000 If yes,descnbe Under DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $1,000,000 C NYS Disability D251202 04/11/18 04/11/19 Statutory Limits E Installation Floater/Property SML93076366 4/15/18 4115119 $250,000 $1000 Ded DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) Certificate holder is also named as Additional Insured. CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <' ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016103) The ACORD name and logo are registered marks of ACORD iWorkers' CERTIFICATE OF ATE clrnpeRK ns oal NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1a.Lego!Name&Address of Insured(use street address only) 1b.Business Telephone Number of insured 631-771-5152 Greenlogic LLC 97 North Sea Road Suite 3 1 c.NYS Unemployment insurance Employer Registration Number of Southampton NY 11968 Insured Work Location of insured(Only required if coverage is specifically limited to 1 d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,-i e.,a Wrap-Up Pobcy) Number 203801104 2.Name and Address of Entity Requesting Prool.of Coverage 3a.Name of Insurance-Carrier (Entity Being Listed as the Certificate Holder) National Liability&Fire Ins Co Town of Southold 3b.Policy Number of Entity Listed in Box"1 a" Building Dept,53095 Route 25 VDWCO23041 Southold NY 11971 3c.Policy effective period 06/15/2019 to 06115/2020 3d.The Proprietor,Partners or Executive Officers are , t u included.(Only check box if all partners/officers Included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in-box"3"insures the business referenced above in box 1a"ibr workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy), The Insurance Carrier or its licensed agent will send this Certificate of Insurance'to the entity fisted above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days-IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)'Otherwise,this Certificate is valid for one year after this form`is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever Is earlier. This certificate is issued as a matter of information only and-confers no rights upon the certificate holder.This certificate does ndt amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'.compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued,by a.certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business Is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or ficensed'agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Nicholas Zulkofske (Print name crized representative or licensed agent of insurance carrier) ✓� { Approved by' (Si lure) (Gate) Title:Authorized Agent Telephone Number of authorized representative or licensed agent of insurance carrier: 631-941-4113 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C-106.2.Insurance brokers are M authorized to issue It. C-105.2(9-17) vvww.wcb.ny.gov i f Suffolk County Executive's 0 ce of Consumer Affairs ffi i DATE ISSUED: 12/10/2007 No. 43858-ME VETERANS MEMORIAL HIGHWAY HAUPPAUGE, NEWYORK 11788 SUFFOLK COUNTY c_ 4 Master Electrician�' doingThis is to certify that business as GREENLOGIC LLC ). having given satisfactory evidence of competency,is hereby licensed as MASTER ELECTRICIAN in accordance ` with and subject to the provisions of applicable laws,rules . 1• regulations • ft Countythe of Suffolk, of • r' Additional Businesses t a• NOT VALH)DEPARTMENTALSEAL ANDX CURRENT I i �- CONSUMER AFFAIRS \ Director •- t 1�1�'i, •,.. ,.��-��1^, ;,:..-, ,''. >•. T i. ..:q� :L-��. '••� � d� :.:ter F: x ���� -fG'`„�j x •`� .:3',�r l�1,'.: IVi fJ �\ fI 11 ;.. ,�t r f, '�'. " fI 1• if ��. \� fi ;,,\. fi `� r 1� , ............ X W. 04, T. g 4 T , Suffolk County Executive's 0 ce of Consumer Affairs VETERANS MEMORIAL HIGHWAY HAUPPAUGE,NEWYORK 11788 DATE ISSUED: 5/25/2006 No. SUFFOLK COUNTY Home Improvement Contractor License This is to certifv that MARC A CLEJAN doing business as GREEN LOGIC LLC having fumished the requirements set forth in accordance with and subject to the proons of applicable laws,rules and regulations of the County of Suffolk,State of New York is hereby licensed to conduct business as a HOME IMPROVEMENT CONTRACTOR,in the County of Suffolk. Additional Bgsinesses NOT VALID WITHOUT DIEPARTMENTAL SEAL AND A CURRENT 'A. CONSUrv,IER AFFAIRS ID CARD Director N 4 X� JAMES J. S TOUT A R C H I T E C T & Assoc. 2 C REG L ANE E AST NO R T H P O . 6 31 — 8 58 93 88 DATE: B.P.# �l U FEE: �D BY: Letter of Certification NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE October 23, 2019 FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED Janusz Residence FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 1045 Dean Drive 3. INSULATION Cutchogue, NY 11935 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. To Whom It May Concern: ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW AT I, James J. Stout, registered architectI' �.nLRer 69, \33i dld= to submit the fallowing. I have inspected � a e&VV' 9 ur§PE@above- mentioned address and have determined the structure and the panel attachment to be adequate to support the new additional load imposed by the proposed solar panel system and complies with the 130-mph wind design load as 2017 New York State Uniform Code (2017 NYSUC), 2017 New York State Residential Code (2017 NYSRC)= (2015 International Residential Code(2015 IRC) (2nd Printing) and 2017 New York State Uniform Code Supplement(2017 NYSUCS) as well the Long Island Unified Solar Permit Initiative (LIUSPI) and the 2014 National Electric Code NFPA 70l 2014 National Electric Code, and the ASCE 7-10. The existing 2"x 8" @ 16"o.c. and 2"x 12: 16"o.c. roof rafters will provide the required support. COMPLY WITH ALL CODES OF Thank you for your understanding in this matter NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF James J. Stout ' , ARD 0 CUFANCY OR EEs U E IS UNLAWFUL 1 ,® WITHOUT CERTIFICATE ��F EDARCy, F OCCUPANCY SJ Sr° T� X101 ELECTRICA►Ls� 02 6 Q� IN ECTION REQUIRED qT �o 0 N E`N GREENUDGWO rE GreenLogic,LLC Approved Janusz,Robert 1045 Dean Drive Cutchogue,NY 11935 Surface#A: Total System Size- 13.080kW Array Size:0.981kW 1 circuit of 3 on a 20A breaker Azimuth:155° Pitch:26° Monitoring System: SunPower PaneUArray Specifications: Panel:SPR-E20-327-E-AC Racking.SunPower Invisimount Panel.61.39"X 41.18" Array.15'5 518"X 3'5 1/8" Surface:24'7"X 7'7" Magic#:Invisimount Legend: ® 3 SunPower 327W Panels SunPower Invisimount Rail / I ® 8 Quick Mount E Lag B 8 2x8"Douglas Fir Rafter 16"O.C. Notes, Number of Roof Layers:1 Height above Roof Surface-4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: AR SNI �s ] sr -A -9 021633 40 OF NES Draw By:MA Drawing#1 of 14 eta.10/22/2019 REV:A DravAng Scale: 1/4"=-1.0' ENERGY GreenLogic,LLC Approved Janusz,Robert 1045 Dean Drive Cutchogue,NY 11935 Surface#A: Total System Size:13.080kW Array Size.0.981 kW 1 circuit of 3 on a 20A breaker Azimuth:155° Pitch:26° Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:15'5 5/8"X T5 1/8" Surface:24'7"X7'7" Magic#:Invisimount Legend: ® 3 SunPower 327W Panels ® SunPower Invisimount Rail 17 ® 8 Quick Mount E Lag, 8 8 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface-4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: 02163' OF NES Drawn y MA I Drawing#2 of 14 Qate,14/22/2019 REV:A Drawing Scale:1/4"=1.0' f GREENLOSEC ENERGY GreenLogic,LLC Approved Janusz,Robert 1045 Dean Drive Cutchogue,NY 11935 Surface#A: Total System Size: 13.080kW Array Size:0.981kW 1 circuit of 3 on a 20A breaker Azimuth:155° Pitch:26' Monitoring System: SunPower 0 Panel/Array Specifications: Panel.SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array.15'5 5/8"X 3'5 1/8" Surface:24'7"X 7'7" Magic#:Invisimount Legend: 1 ® 3 SunPower 327W Panels ® SunPower Invisimount Rail ® 8 Quick Mount E Lag B 8 2x8"Douglas Fir Rafter 16"O.C. Notes, Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: AR Cp-5 WSJ ST -A '9 - X216 33 yoe. OF NES Drawn y:MADrawing#3 of 14 Asa. .10/22/2019 REV:A Drawing Scale:1/4"=1.0' GREENLOMM" ENERGY GreenLogic,LLC Approved Janusz,Robert 1045 Dean Drive Cutchogue,NY 11935 Surface#3: Total System Size:13.080kW Array Size:3.597kW 1 circuit of 11 on a 20A breaker Azimuth:245° Pitch:18° Monitoring System: SunPower PaneUArray Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'10 7/8"X 10'3 1/2" Surface:23'10"X 13'1x x x x " Magic#:Invisimount p ILegend: y N ® 11 SunPower 327W Panels { +� �!N SunPower Invisimount Rail ® 19 Quick Mount E Lag X X 8 2x8"Douglas Fir Rafter 16"O.C. x x Notes: Number of Roof Layers:1 Height above Roof Surface:4" V AZ Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: A �C) , Tom'`' i C L 510 1 021633 A CF NE Dra ,, y:MA FDrawing#4 of 14 LSULC�:10/22!2019 1� V:A Drawing Scale- 1/4"=1.0' GREENLOGOV ENERGY GreenLogic,LLC Approved Janusz,Robert 1045 Dean Drive Cutchogue,NY 11935 Surface#B: Total System Size: 13.080kW Array Size:3.597kW 1 circuit of 11 on a 20A breaker Azimuth:245" Pitch:18° Monitoring System: SunPower PaneUArray Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'10 7/8"X 10'3 1/2" Surface.23'10"X 13'1" Magic#:Invisimount Legend: 11 SunPower 327W Panels ® SunPower Invisimount Rail ® 19 Quick Mount E Lag KI 8 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 i Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System.3.5psf FI I IFE-L I I I Engineer/Architect Seal: '( A�y� 1'0'5 6�� FN Draw ry y:MADrawing#5 of 14 �atc 10/22/2019 REV.A Drawing Scale- 1/4"=1.0' GREEENL069V ENERGY GreenLogic,LLC Approved Janusz,Robert 1045 Dean Drive Cutchogue,NY 11935 Surface#B: Total System Size:13.080kW Array Size.3.597kW 1 circuit of 11 on a 20A breaker Azimuth:245° Pitch- 18° -f4 Monitoring System, SunPower Pane flArray Specifications: Panel.SPR-E20-327-E-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" 2 Array:20'10 7/8"X 10'3 1/2" Surface:23'10"X 13'1" Magic#:Invisimount p Legend: V NV Ny Q::Q 11 SunPower 327W Panels L ® SunPower Invisimount Rail ZL Z� AN.........41 ® 19 Quick Mount E Lag 8 8 2x8"Douglas Fir Rafter 16"O.C. 2 Notes: Number of Roof Layers:1 Height above Roof Surface:4" x1v \V Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seat: Aq 021633 Drawny:MA Drawing#6 of 14 4c 10/22/2019 REV:A Drawing Scale:1/4"=1.0' � GREENLormc® - ENERGY GreenLogic,LLC Approved Janusz,Robert 1045 Dean Drive Cutchogue,NY 11935 Surface#C: Total System Size:13.080kW Array Size:4.578kW 1 circuit of 8 on a 20A breaker 1 circuit of 6 on a 20A breaker Azimuth:335° Pitch:12' Monitoring System: SunPower Panel/Array'Specifications: Panel-SPR-E20-327-E-AC Racking:SunPower Invisimount p Panel:61.39"X 41.18" Array:22'4"X 15'5 5/8" Surface:27'5"X 18' Magic#:Invisimount Legend: ® 14 SunPower 327W Panels ® SunPower Invisimount Rail x x x x 0 27 Quick Mount E Lag IT78 B 2x12"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:l Height above Roof Surface:4" Materials Used:Quick Mount,SunPower xi Added Roof load of PV System:3.5psf Engineer/Architect Seal: AR7-- ---------------- 021633 COQ OF NE'N Dra y:MA Drawing#7 of 14 'Data'10/22/2019 REV:A Drawing Scale:1/4"=1.0' G R E E N L® O © ENERGY GreenLogic,LLC Approved Janusz,Robert 1045 Dean Drive Cutchogue,NY 11935 Surface#C: Total System Size.13.080kW Array Size:4.578kW 1 circuit of 8 on a 20A breaker 1 circuit of 6 on a 20A breaker Azimuth:335° Pitch:12° Monitoring System: SunPower Panel/Array Specifications: Panel.SPR-E20-327-E-AC Racking:SunPower Invisimount Panel.61.39"X 41.18" rl Array:22'4"X 16'5 5/8" Surface:27'5"X 18' Magic#:Invisimount Legend: ® 14 SunPower 327W Panels ® SunPower Invisimount Rail ® 27 Quick Mount E Lag B 8 2x12"Douglas Fir Rafter 16"O.C. Notes. Number of Roof Layers:1 LE Height above Roof Surface.4" Materials Used-Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: ...... ....R_- ST spa �.• ,9c 02163 OF NON Drawn :MA Drawing#8 of 14 0/22/2019 REV:A L Drawing Scale: 1/4"=1.0' ENERGY GreenLogic,LLC Approved Janusz,Robert 1045 Dean Drive Cutchogue,NY 11935 Surface#C: Total System Size:13.080kW Array Size:4.578kW 1 circuit of 8 on a 20A breaker 1 circuit of 6 on a 20A breaker Azimuth:335° Pitch:12° Monitoring System: SunPower 3 4 Panel/Array Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount p Panel:61.39"X 41.18" Array:22'4"X 15'5 5/8" Surface:27'5"X 18' L------- Magic#:Invisimount Legend: ® 14 SunPower 327!A!Panels 3 4 SunPower Invisimount Rail ® 27 Quick Mount E Lag H 2x12"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower 3 4 Added Roof load of PV System:3.5psf Engineer/Architect Seal: A R �5 , ST C SO L y 021633 AO Or Ne Dra By:MA Drawing#9 of 14 —dte:10/22/2019 REV:A Drawng Scale: 1/4"=1.0' GREENLOGICO ENERGY GreenLogic,LLC Approved Janusz,Robert 1045 Dean Drive Cutchogue,NY 11935 Surface#D: Total System Size:13.080kW Array Size:3.924kW 1 circuit of 12 on a 20A breaker Azimuth:65° Pitch:33" .......................................................... Monitoring System: SunPower PanelVArray Specifications: Panel:SPR-E20-327-E-AC Racking:SunPower Invisimount Panel.61.39"X 41.18" Array:20'10 3/8"X 10'3 1/2" x x Surface:33'9"X 166" Magic#:Invisimount Legend: ® 12 SunPolnrer 32711!Panels SunPower Invisimount Rail x x x _X ® 20 Quick Mount E Lag 8 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: 9 021633 y0� fa OF NO Dram y:MA Drawing#10 of 14 10/2212019 REV•A Drawng Scale-3/16"=1.0' 'EL®G0�® ENERGY GreenLogic,LLC Approved Janusz,Robert 1045 Dean Drive Cutchogue,NY 11935 Surface#D: Total System Size.13.080kW Array Size:3.924kW 1 circuit of 12 on a 20A breaker Azimuth:65° Pitch:33' Z . ...... ...... ...... ...... ...... ...... .... Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-E20-327-E-AC rZ Racking:SunPower Invisimount Panel 61.39"X 41.18" Array:20'10 3/8"X 10'3 1/2" Surface:33'9"X 15'6" Magic#.Invisimount Legend: IV ® 12 SunPower 327W Panels SunPower Imnsimount Rail ® 20 Quick Mount E Lag 8 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: AR a STS e -9 421633 �0 Op �yE Drawn y:MA Drawing#11 of 14 "eats,-10/22/2019 REV:A Drawing Scale:3/16"=1.0' LOWC CNr GreenLogic,LLC Approved Janusz,Robert 1045 Dean Drive Cutchogue,NY 11935 Surface#D: Total System Size.13.080kW Array Size.3.924kW 1 circuit of 12 on a 20A breaker Azimuth:65° Pitch:33' .......................................................... Monitoring System: SunPower Panel/Array Specifications: Panel.SPR-E20-327-E-AC Racking:SunPower Invisimount Panel 61.39"X 41.18" 5 Array:20'10 3/8"X 10'3 1/2" Surface:33'9"X 15'6" 744 Magic#:Invisimount Legend: ® 12 SunPower 327W Panels ® SunPower Invisimount Rail 5 ® 20 Quick Mount E Lag 8 B 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: AR ST -A c l50 -9 021633 Ad OF N� Drawn y:MA Drawing#12 of 14 DT .1012212019 REV:A Dravnng Scale:3/16"=1.0' No Vent Pipes Will Be Covered By The Solar ArrayG R E E��LO a 9 C® LEGEND �- ENERGY AR -Access roof per 8202 definitions RAP -Roof access point-to be away from RWV -Roof with valley, GreenLogic,LLC Approved overhead obstructions,doors. 18"minimum from valley Janusz,Robert windows,decks,fences,landscaping 1045 Dean Drive GA -Ground access area per R324.7.3 width AP -Access Pathway,36"minimum SVO -Smoke vent operation per Cutchogue,NY 11935 to be same as AP as measured at eave width per R324 7.4 and R324 7.5 R324.7 7,18"minimum from ridge Total System Size:13.080kW 1 circuit of 3 on a 20A breaker 1 circuit of 11 on a 20A breaker 1 circuit of 8 on a 20A breaker 1 circuit of 6 on a 20A breaker 12 SunPower 1 circuit of 12 on a 20A breaker RAP 327W Panels Azimuth:155° Monitoring System: G7 D SunPower D "o ——————l Panel/Array Specifications: Panel:SPR-E20-327-E-AC I Racking:SunPower Invisimount Panel.61.39"X 41.18" Array:36'2"X 56'4" i Surface:75"'X 60'6" RAP I RAP RAP Magic#:Invisimount I Legend: I GA I GA ® 40 SunPower 327W Panels i SunPower Invisimount Rail DAPI 1 Is 74 Quick Mount E Lag tcn I I I IAP 8 0 2x8"Douglas Fir Rafter 16"O.C. 1 ' I I i I I _j p 2x12"Douglas Fir Rafter 16"O.C. ------SvO———— ___ I I ----5 --- ----- Notes- I I Number of Roof Layers:1 I Height above Roof Surface:4" I Materials Used.Quick Mount,SunPower m IWXAdded Roof load of PV System:3.5psf Engineer/Architect Seal: � R A 11 SunPower 'CO 327W Panels 3 SunPower 14 SunPower 327W Panels 327W Panels F c LS,O ,9 021635 OP NE`� Meter Drawn y:MATREV: rawing#13 of 14 10/22/201 A Drawing Scale: 1/16"=1.0' E LOMCO ENERGY GreenLogic,LLC Approved Janusz,Robert 1045 Dean Drive Cutchogue,NY 11935 " I Total System Size:13.080kW 1 circuit of 3 on a 20A breaker - 1 circuit of 11 on a 20A breaker _ ._. .- - _ _---- --__------.-- __._---- _------ _-- -------- --- --!___- ._ ,, _ ----------.---__•-_-- _-'_-__ ..---•___ _ --___ _ _- _! --__:______,_ 1 circuit of 8 on a 20A breaker 1 circuit of 6 on a 20A breaker 1 circuit of 12 on a 20A breaker 3 i ; Azimuth:155° ! Feil WKEW Lia ' -- - ._ _. _-�------ -- - - - - --�--- ---- - ---• . .._�- ----- - --- - -- - --- ------- ----- -- - - - y ( N Monitoring System: S s SunPower Panel/Array Specifications: - - - -- --- - - -- - -- - - - -' - Panel'SPR E20 327 E AC CastAtinirYI11K4xrtbl'gElo& VElacCAllnt' nHasirg ;` 74 Racking SunPower Invisimount �h6k7/8' irgPlLg 74 Panel:61.39"X 41.18" - - -- - - - - - - - - - - - Array'36'2"X 56'4" 5/Vx59'ft+bad fag53Ew 74 - — - Surface:75"'X 60'6" agc : nvsmount S5(]B'f U1�er ' 74 Magic#:Iii t Legend: 4 0 SunPower 327W Panels ! ! i SunPower Invisimount Rad 0 74 Quick Mount E Lag - - - - - - - - - --- --- - - - - - - ` 8 8 2x8°Douglas Fir Rafter 16"O.C. __; _ ..-- ____._ .. . .__ •_-__ __ � . I 2x12"Douglas Fir Rafter 16"O.C. - - - - ---- - - { - - --- - - ! - - ! { Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Quick Mount,SunPower Added Roof load of PV System:3.5psf EngineerlArchitect Seal: AR 1 1021633 yob �F N�v� Drawn By:MA Dravnng#14 of 14 te:10/22/2019 REV-A Drallong Scale: 1/16"=1.0' EXISTING SERVICE PV-SA-1 AC-COMBINER PANEL 120/240, 1 PFS, 3W ' . . . AC-CMB-1 I • • • (PV LOADS ONLY) FS i 200A KWH Fm' PV-SA-2 1 . . . O . . . 1 1 BKR-1 AC-DSC-1 ' 1 AC DISCONNECT T T I BKR-2 �— PV-SA-3 0 I • • • �4 'FEF BKR-3 r MAIN BKR-4 i A B N PV—SA-4 „ 1I I FUSED E • • • 119 N . . . 2 1 N IEGC � X111 1 � N TYPICAL PV MODULE WITH INTEGRAL DC/AC INVERTER 1 1 1 1 I i ilil iEGC I i :j2E!Gc I E 1 111 ` I 1 i EXISTING AC PANEII.EXISTING i 1 1 1 1 1 ___ ___ _ 1 __ GEC _- ----- 1 GEC --_ LLl�®__-- ---- L------ PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Janusz, Robert ; 1045 Dean Drive _ ENERGY Cutchogue, NY 11935 ELIMINATING THE DOST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Janusz-3LD1 Revision: 1 Revised: 9/19/19 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-E20-327-AC, 1-CIRCUIT OF 10-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-E20-327-AC, 1-CIRCUIT OF 10-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-E20-327-AC, 1-CIRCUIT OF 10-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-E20-327-AC, 1-CIRCUIT OF 10-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 3270 WATTS 211-264 VAC 13.30 A AC 240 V, AC PV-SA-2 3270WATTS 211-264 VAC 13.30 A AC 240 V, AC PV-SA-3 3270 WATTS 211-264 VAC 13.30 A AC 240 V, AC PV-SA-4 3270 WATTS 211-264 VAC 13.30 A AC 240 V, AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Janusz, Robert f N 1045 Dean Drive N ER G Y Cutchogue, NY 11935 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION __Pa 2 of 3 Drawing No: Janusz-3LD1 Revision: 1 Revised: 9/19/19 ,r NEW�- EQUIPMENT-----------------_--_— EXISTING SERVICE PV-SA-1 - ---�-- /� AC-COMBINER PANEL _-� 120/240, 1PH, 3YV ' • . . AC-CM6-1 I • • • '� (PV LOADS ONLY) I 200A KWH PV-SA-2 A j I - . . . N2 1J I BKR-1 AC-DSC-1 ! AC DISCONNECT _ -__ I I I BICR-2 I PV-SA-3 A ! I � . . . � 1 I I BKR-3 � - MAIN 4III BKR-� PV-SA-4 IIIFUSED Ff== NIEGC I � - IIII I ; N TYPICAL PV MODULE WITH IIII I I INTEGRAL DC/AC INVERTER IIII BOG I EGC IIII I I EXISTING AC PANEII.EXISTING EC LI_.1i------------L--------------- -�--- GECG ® �S CU PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Janusz, Robert OR E D4 1045 Dean Drive _ ENERGY Cutchogue, NY 11935 ELIMINATING THE COST QF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Janusz-3LD1 Revision: 1 Revised: 9/19/19 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-E20-327-AC, 1-CIRCUIT OF 10-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-E20-327-AC, 1-CIRCUIT OF 10-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-E20-327-AC, 1-CIRCUIT OF 10-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-E20-327-AC, 1-CIRCUIT OF 10-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX. AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 3270 WATTS 211-264 VAC 13.30 A AC 240 V, AC PV-SA-2 3270WATTS 211-264 VAC 13.30 A AC 240 V, AC PV-SA-3 3270 WATTS 211-264 VAC 13.30 A AC 240 V, AC PV-SA-4 3270 WATTS 211-264 VAC 13.30 A AC 240 V, AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Janusz, Robert E, <, � 1045 Dean Drive , ._. . '€ ' Cutchogue, NY 11935 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION f3 Drawing No: Janusz-3LD1 Revision: 1 Revised: 9/19/19 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL 250V, 200A, NEMA-1, 1-PH, 3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-4 CIRCUIT BREAKER, PV-SA-4 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 60A, NEMA-1, FUSED; FUSE RATING: 60A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 2" PVC-40 4 / 6 C THWN-2 2" EMT 4 / 6 1.) CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUIT TO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE RE- QUIREMENTS. 4.) NOTE: GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS .� Janusz, Robert GREENLOGICO 1045 Dean Drive �gERGY Cutchogue, NY 11935 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Janusz-3LD1 Revision: 1 Revised: 9/19/19 SUNPOWERO SunftwerO -Seri s: -327 E19-320 SunPower' Residential 5AC Module Built specifically for use with the SunPower Equinox'«system,the only fully integrated solution designed,engineered,and warranted by one manufacturer. i � Maximum Power. Minimalist Design. Wks MRS Ar Industni-leading effclency means more Dower and savings rAVper available space Wrh fewer mcdu es requ,red and 'redder tncroinverters,less ;s truly more Highest Lifetime Energy and Savings. Designed to deliver 60%more energy over 25 years in real-world conditions like partial shade and nigh temperatures' uncfil lly Ditff rAnd,fie en; `z 2� up to 60% more lifetime a Vii, energy �,"� ✓. - Ln ^t. ` . 5 J G is <n 25. The S6niDgw�ei',Maxean1'SolarxCell P ~; , Years of operation o •fir vibles'hig'ies:t�f(ic`.tncv" c3vc11� ni,':i �uIPS d,Y;tJrt7iatchC-C`-e 001;it Best Reliability. Best!Warranty. "= i�atCn;2G so id rt7tal'`oUli :lt'on~' With more then 25 million medu es deployed around Prevents om. kahe. n l co rosio' t t�e world,Sunf'cwer technology:s proven to last.that's why we stand benil.d our module and micro nve`ler with the indus:rys best 25-year Combined Power a^d = i Product Warrant including the highest Power b�rarranty in solar Factory=integrated Microinvertbn SILT'I�.;I?r,fGSter'InSt$II:1tI0G�_'..'S`: .a' '-'y <.`» ;r$ ,• �° ! �`,"., O i;tigrated vlire management ;y _' 12°!° r,3h:itcohri more i- r, ti ._reii`a'r _ ower I 7cl;3fVtra A'c in year }` 25 2-1 25 Years of operation U. E-Series: E20-327 I E19-320 SurPcwerl Residential AC Module Inverter Model Enphase(Q 7XS(IQ7XS-96-ACM-US) @240 VAC @208 VAC P 33,2 0 VA 320 VA Cor un,ouvi Cmu'm't P,-"(,i(,r 1-1 VA 15 VA C. 3 2 (1- L: 20F, I S- -2) V-111511 is Pei I" i-(LL;6,ars i r,-lit- 12(.;irigle phasrl 10(,'A,(,'QGIC)kl,r,Je ,,E;- .,nf(:Effi-,ency 97 0,s Nor i frnflt.rancv qt,of-y 1/ '68 I'z Sl--,,rt to i-r-atj.Cu-r.2r-aver C,,rles S 8 A rms -,Dj7,e Cass AC Por: III 'C ,Drt Ba-,,feed Cii-rcit '8 n*A Pj,:,Dr 0 1 IL,ad / 3 7 1,,g `Jo p4 v-bai- 'r)r -,i,ee-l-i,jsc i,est-id,i 10,1', cam SPR-E?0-327-E-AC SPR-F19-320-F-AC : y,-a-li-iitcd p,-.-,,.,erwa,ran,-./ 25-vea- I: sled proouclwar-arit� PowPovuer-Pncm) 2-,7 W 32C,Vv Lj 173' Poer Tol 4 UL Ce-r 1 '41 1Ii-I:L-1 module Efflclent-�' lend L 1 141 AC Mocl,ile(71ype 2 fn rates) I i I-em--I Co—e= -0 354VIC -0 351,l1/'C Co!'mlla'ice Lil-62"09 / 7(-6'�09-2 - Da,t I b Clays B .1hrC--bypass 1Ct:S-00Cj-1 UZ:ss 3 shadr,To. mcclik-lovH rn,-,ximum I -CAN/CSA-C2?2\10 107 1-01 power point irac:eirg CA RJe 21 (U-17'I SAY (InClUcesVolz/va,and Rear-ove Powe,Pr onty) downt:-q:iipmenr- 1 Oper.-ImgTernu -;'O'F tu '8L,if to r;5°C) I- Enables naliario,- r-c-cem-ric-o.-ith Max- r-Amoient Tem '-22'F(501C)- - s'NEC�)C C(AC mocule) ' V1 nd 62 F-J '3000 Pa,'305 k8g1712`rant&rack NEC'690 12 F,,,jpjo (j;i,-d(-and ou.,,jce the amlv) Max Loa:: Sno\,,., i 23 QSf,000 P3,G'1 1<.-/rT--front NEC 691)11,AC(-.-)nrie(ic, ,,Fc,'O�3(A)-('--)(1) n-pac,RFE-istaice rcn'2S mrn,C an e-er hat -i-,S-2 mph(23-n1s) i Wl,en iseL w,h hvisi\4c..r't r.ckmg and accessories Im— (UL 27 03) Z71 -VcdL,C'grourd r,gin I Lord ni-1.9rc,j-h invisiVoirt _,oar Cells 96,Vciocj ystaillne lvlaxeor Gen I i Class",fire r:ted Front I gh-1,an1,-n,ss.or te-pe,ecl glass md- Aflienwed w,,h A'-,Y;ocule Q C,mlkl.at]( (UL 6701"nd F r-,I-r o 9 oc,�vo coa rg- U-2238)6 I Enmonm-nlal Ram- Ourdoni ru,r,r ,m oa(.m P,ik J,L,,)nne(t Fr 171(' Class' n!ack<•nori?ocj(niclics,A,,',M.A rarmg) I P;D Tes, Potent,--nci,cen,r1p,anal w tre- 42 9 1,)s k8) 1558 min(61 3'n I Rec or-n)ei idpci Vax 31r L33'11rn; 1 360 kj1"'r'1r'Km,,j 0-. -ic,10P or 46 mni et,cient,a')pr'.X, mv--er;?,6y per r41--tt(I—s'-d or it'll ITIO-JUIL (1.9 and Pvcm-;,O 7541v-s c.ca,cdanon(Ca-ireo,j,7 ,to! 'Sur�'co"e M'io Ile Dtwe.la-'Ian RoLe.. Sur)P"'W'-'r 201 ii 2 BDed oi i s-ml,)I olowsrle.�,,'Zlj ',t 01 n Vv,1) 1)f C L'10"Wf 11 OW Plr 0-v; 1045 mm 30 ram Jn-,i-ry 2)1 1412 ir) 3#1 wi 11,1 n-, ri twzlve 1`0 1 IN",d u I el Pl-'rt Pv-e,1, r ,'Aa ga a i r,o 2 C I j, ij r, c r mo r i I,-D eg,,-rm-,i o n Pa i ,t, R 0 V,-r w-,i Ito I pipe,,2913 1 4 FJCtOr,'bLI-1'--47-20 4 CA k 1e 21'de'.JIZ 3et-,U`gL pro'-e SCL Ju;11 g 393 mm (0-im ',-c-ne Ecu t,o>1--*A:a-,,,-i G-i i le,,S'S 101 fc,rm e irfo-mi,ion (15.5 1n) 5 Swridar d fest(::,d i�('00 Wrn a r,3 c:;n(_,Ai ,5 t1 o(-I-:,A b,dti or, stan,h,o SOI,'Sr,irrei-c,]ACCSFramvoltage rrc-ule 437 mm b H;s product is U. L sttic,as'1\b}SE ar-d cilio-Tis w,al i ,j c z:nc` jrC 2017 GT, i. 117 2 ir) zrd C22 1-231,,>-iUle 64-213 2apjci Shut dovin of-j SYst'--s `or AC anc ,1C orductz)rs. 'vhc'1'1'�'and d.Lwd!I-,tGrrwrlluf�'V.H el.111"tIO" V-� See vrmw s.inDower carr.-acts form � om ruteircc,mtwr—it�'r HORACM P,-.AM MX�� U of 1111,1, ,P6 eX(eWled CIO-,Sheet AVA-4 epv� Q P �W e N WE Re Spec fi:,,t c n s i iclu c--d,r th s, e-,:zi,e s-1 f)j e ri t0 J--vie:Villi C.L C O'Ke LISTED"78330 A!I`,ght-,I`,:--ivPd ,P SUNDGO.'Eillogoano Co noravor,1 the L,S arc c,,h ir coi.imc,3-is SO,,S'J,%'1POV,t Q me,),c f-,+,tyaml 531948 Revi-i' A Gm�UdIIII i; NMI' m! :mir M' i EDEN= 0 Simple and F8t Installation 7' • Integrated module rail,ground fng Pre asserrib,ed mid and end Idamps' • I_eVjLai:lngslid clarnp(or easy placerrie rit • -Mid clarripwidth facilitates consistent,even module spacing Simple.pro-di-illed:rail splice • UL 2703.1 isted,ir,,cegrated,grolur)d*rg, Flexible Design -Addresses nearly all sloped residential'roof-s D(?sigi i it i Uiuscape and portrait Rails enable easy obstacle_mar,agerrert Cus,orer-Preferred Aesthetics 41 module and#Tmounting aesthetics Besk',iri-class.sy-sceryi-ac;sthetics, Elegant Simplicity • Prernhjm,low-profile design Black anodized components SunPower'� InvisiMount" is a SunPowei-designed • Hidden mid clamps and end clamp, rail-based mounting system. The InvisiMount system and capped,flush'rails addresses residential sloped roofs and combines faster Part of Superior System installation time, design flexibility, and superior-aesthetics. Br IL .ase wi*Lh SunPov`ver.DC and AC,modules The InvisiMount product was specifically envisioned and Best-in-,class systerri:reliabilitVand aesthetics Combine With,SUnPoo/er modules and d 4 engineered to pair with SunPower modules. The resulting rryonitoring apo system-level approach will amplify the aesthetic and installation benefits for ooth homeowners and installers. sunpower.com _R� di" TUF- ".4 Module-i Mid Clamp ano Rail Mociu,el Eno Clamp and Ra I MIC Cl<lrnr Eno Clernp Rail&Pall Splice (iroi,iri Lug A5sernbly Eric.,C.;p A, AflA iftA WOOZ i Temperature -40°C to 90"C t—.0"F to 194'F) J......................... IMaK Lcac(LRFD) 3000 0a uplift- A'Sl 30t 6000 Pa dtywr,oi ze Mid Clamp Blick cyide starless steel 62)-,2 2 oz) Eric clarno Black anodiwd E11LA"Int 411 J110Y 110 g(i 88 Ciz) 1 nail Black ancloized aluminum alloy 6005--6 1 830 gim(9 07/ft) Rail Splice Alurnin,jrn alloy 600, T.5 -j 8qo g/m(9 clzift) ?5-year orcduct r. *ran Warranties Gr cunt Lu.- 304 ria Ness I I Oc',5 g/m 3 75 oz) 5-yea'fns-iwarn cmv Assemb,y ,A2-70 noit,nn-plated copper lug) L End ao_1 Black acetal(?Oivl)copolymer 10 4 k(0 37 cL) I-11-2103L,sted Certificat on, Class A=,reRated Comoosicion Shingle Rafter Attachment AppApplicationtion W, " _k od CorrioositiclnShngleRco Deck rig Attachirlt=nt & SEN I t Cu, and;71at�ile Roof.Atcachrnent Universal jr,te,%ce for Other Roof ktachr-rients i I RpFe•to cinfattaoirnem�a,dvvare rr.,nuf2ctjrers clo,,imentza:lor 1NModi.jlCframe 0m is(Ornpa,,wewith ihty lnv;sim)int s,^,ern:cr:iirva for '0 201',cur,Dcwer Corp iration All R,FnES Resorved Sj%PO'*[R,the SJNJP(_v^&R logo,and iNV SINIOUN i a e rraderna,Ks or egi!itcrcil ' Power Corot of thc'r reavecOve owners sunpoover corn tracer n"'I's o fSuii -al:ori All othe,trade.mz�"!, lie tile pro Speciflic'ation s nCiLded in'this datashe ct siljou to dial igl:vithou l:notice Document#509506 RevC