Loading...
HomeMy WebLinkAbout44817-Z �p�gUFFO(qCp Town of Southold 7/8/2020 0 . P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41240 Date: 7/8/2020 THIS CERTIFIES that the building AS BUILT ALTERATION Location of Property: 3500 Pine Neck Rd, Southold SCTM#: 473889 Sec/Block/Lot: 70.-12-3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/11/2020 pursuant to which Building Permit No. 44817 dated 5/28/2020 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"air conditioning_unit as applied for. The certificate is issued to Marone Stephen Jr Fam Trust of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 44817 7/6/2020 PLUMBERS CERTIFICATION DATED Authorized Signature �suKai TOWN OF SOUTHOLD BUILDING DEPARTMENT affN TOWN CLERK'S OFFICE oy . er SOUTHOLD, NY 0 BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 44817 Date: 5/28/2020 Permission is hereby granted to: Marone Stephen Jr Fam Trust 1855 Stone Ave East Meadow, NY 11554 To: legalize "as built" AC unit as applied for. At premises located at: 3500 Pine Neck Rd, Southold SCTM #473889 Sec/Block/Lot# 70.-12-3 Pursuant to application dated 3/11/2020 and approved by the Building Inspector. To expire on 11/27/2021. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $400.00 CO -ALTERATION TO DWELLING $50.00 Total: . $450.00 Building Inspector r � 1 IForm No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses, or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. 3 (C) New Construction: Old or Pre-existing Building: (check one) ( ) Location of Property: ���� Pine Ne t L 'Ed 1()1 Auld House No. Street �� _/- Hamlet Man f Owner or Owners of Property: t 1tC��L�h a(�(,J !fie PSD l Th6s�t when Ld1�h�� Suffolk County Tax Map No 1000, Section DU Block Z Lot 3 Subdivision �j Filed Map. Lot: Perm11rrit No. `� Q I Date of Permit. Applicant: Health Dept Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ ), 1LLJ TTt Appl c nt Si attire . oF soupy®� Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 sean.devlin()-town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To. Marone Stephen Jr Fam Trust Address: 3500 Pine Neck Rd city.Southold st: NY zip: 11971 Building Permit#: 44817 Section 70 Block: 12 Lot 3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Wildwood Electric License No: 4836ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt 2 Wall Fixtures Smoke Detectors 4 Main Panel A/C Condenser 2 Single Recpt Recessed Fixtures CO2 Detectors 2 Sub Panel A/C Blower 2 Range Recpt Ceiling Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 2 4'LED Exit Fixtures 11 Pump Other Equipment Notes* " AS BUILT " " NO VISUAL DEFECTS " AC and Added Smokes/ CO2 Inspector Signature: Date: July 6, 2020 S.Devlin-Cert Electrical Compliance Form.xls 0f SObIyO� Li 11617 LJ V . Two] cex # f TOWN-OF SOUTHOLD BUILDING DEPT. 765-1802 -=INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)i;v it,� [ ] CODE VIOLATION ] PRE C/O REMARKS: fI N/lam f A. �j:g I el+f, 1AJ S_AgI ;r IQIJ DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS ro FOUNDATION (1ST) �A y -------------------------------- FOUNDATION (2ND) C ROUGH FRAMING& y PLUMBING p � ry 1 INSULATION PER N.Y. H STATE ENERGY CODE FINAL ADDITIONAL COMMENTS O o m H , x d H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you'have or need the following,before applying? TOWN HALL S aTn {'Y)Q,11u�C�C�UYf fCS Board of Health SOUTHOLD, NY 11971 CS kY uniiS Uets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined 20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: t Appioved 20� , 1G moo: Disapproved a/c ]V Phone- 5l JV'�5aa0 Expiration 20 Bui di spector i Zi' ID R APPLICATION FOR BUILDING PE MIT 1i i '• is •� Date �U roh I(J `�` `-•' MAR 1 1 2020 , 20 20 INSTRUCTIONS a. This applicgti n79,LT3STlTdEoi pletely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate-plot.plafi;to scale:Feela'ccording to schedule. b Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways c. The work covered by this application may not be commenced before issuance of Building Permit. d Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work.. e. No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings,additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,Vusing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. ( ignat it 4JPYlcant or nam ,if a corporation) �Z����OOC� ��re ��l/b�i r`moi v►9�C �y 18"73� J(Mailing address of applic nt) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder l Name of owner of premisesoo e ma rbnc -T(,mi )y (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 3500 21 n-e 1--J-F C L 20k SUutk 01 d House Number Street Hamlet County Tax Map No. 1000 Section - Blo-Cl'° ;`°` a�4 Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy !!51 f)Q �A- m T b. Intended use and occupancy SCCVy\A _ 3. Nature of work(check which applicable): New Building Alteration Repair Removal Demolition Other Wor �, C (Description))Z--r PO Estimated Cost Fee (To be paid on filing this application) 5. If lling, number of dwelling units Number of dwelling units on each floor If garag number of cars 6. If business, comme ' 1 or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions-of existing struc if any: Front Rear De Height, NO er of Stories Dimensions of same structure with alterati s or additions: Fron Rear Depth Height umber of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number tories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone o se district in which premises are situated Does proposed constriction violate any zoning law, ordinance or regulation? YES NO� 13. Will lot be re-gra d? YES NO Will cess fill be removed from premises? YES NO� 14. Names of Owner of pr ises Address Phone No. Name of Architect Address Phone No Name of Cont r Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF&ffd Nom) g I/� S�2Q`12n U� GVD V -e- being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)O.s the Ot,.)V1-,e/ (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application, that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this 1day of clra1--- 20 --7U ke— Notar�Public o Mumbo VV ig Mrof Applicant Now M19,stare ofNmYaR Rio.02MAd8NO QnH®ad In SuQoQc G�tstlonEspip�rn I�3 ,���.� f O�OS�FFO(KCOG BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD y� Town Hall Annex - 54375 Main Road - PO Box 1179 CD o - _Southold, New York 11971-0959 y o� Telephone (631) 765-1802 - FAX (631) 765-9502 ��l rogerrasoutholdtownny.gov — seand(a�southoldtownny.gov APPLICATION FOR ELECTRICAL INSPECTION ELECTRICIAN INFORMATION (All Information Required) Date: /o 2) Company Name: I Name: License No.: email. Address: wa dinq Phone No.: JOB SITE INFORMATION (All Information Required) Name: M aro Address: U Cross Street: Phone No.: 1(P Bldg.Permit# X01 L4 email: vo Tax Map District: 100 Section: D Block: Lot: ,3 BRIEF DESCRIPTION OF WORK Please'Print Clearly) Circle All That Apply: Is job ready for inspection?: (3YE / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect - Flood Reconnect - Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame, Pole Work done on Service? Y N Additional Information: i PAYMENT DUE WITH APPLICATION Request for Inspection Formals x•i u UEC `^ I�+�+, •3• x �Y"„ � 3 [[/♦����, ii//��tt •fie/`hp, "3" ,w`[( T[[ � .. •saw _. ^' r.. ... ' i, e. Heating&CoolingSystems w '' i ? $ :, ;, :` „ . 1' 011 AAPPROA NOSED USE IS UNLA��Fi°P�DATOCCUPANCY OR 'B.P.# WIT � � ^►� r®UT CERTIF12, tT[FEE: BY: ��;��� NOTIFY BUILDING DEPARTMENT AT . F29A O I qy .M TO 4 PM FOR TF ACTIONS: DU AGUARDTM COIL PROTECTION—Made of a coated steel WECUIR gnd-with vertical 3/8 in spacing, is designed to help protect ° v '( ° TE coil from inclement weather, vandalism, and incidental hits. It provides protection while not restricting airflow and maintain- 2. R PLUMBPase of coil inspection and cleaning ELECTRICAL RANGE—All units are offered in 208/230-v sin- N MUSq1e phase only D. WIDE RANGE OF SIZES—Available in 7 nominal sizes from LL MEI ugh 060 to meet the needs of residential and light com- ODES er c /pplications NSIB*� ER-PROTECTIVE CABINET—Steel is galvanized and oaW-With a layer of.zmc phosphate.A coat of modified poly- ON ER RORaowder is then applied and baked on, providing each unit with a durable finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting, rust- resistant,quality appearance TOTALLY ENCLOSED FAN MOTOR—Provides greater reliabil- ity under adverse weather conditions and dependable perfor- ° ° mance for many years. The permanent-split-capacitor type motor was designed for optimum efficiency. Then, under ° extreme conditions, the motor was tested and qualified to help o ensure the greatest reliability. UNIT DESIGN—Copper tube, enhanced aluminum fin cod is COMPLY WITH ALL CODES OF designed for optimum heat transfer.Vertical air discharge car- NEW YORK STATE & TOWN CODES ries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump style base pan for easy AS REQUIRED AND CONDITIONS OF removal of water, dirt, and leaves APPLICATION VERSATILITY—The 597C can be combined with a wide variety of evaporator cods and blower packages to SO'�fit t6��0ARD provide quiet, dependable comfort Unit can be installed on a roof or at ground level on a slab SQUITEES EXTERNAL SERVICE VALVES—Both service valves are brass, back seating type with sweat connections Valves are externally located so refrigerant tube connections can be made The Relian ero u►et'9�y_stem(AQS)consists of 3 design fea- quickly and easily Each valve has a service port for ease of tures to achieve ultra-low sound ratings checking operating refrigerant pressures Aerocoustic Design featuring the Aeromax opening and wire EASY SERVICEABILITY—One access panel provides access dome top results in quieter and more efficient operation. to electrical controls and compressor. Removal of wire dome Energy-Efficient Fan and Fan Motor provide a slower fan gives access to fan motor and removal of the top gives access motor, reducing noise and improving efficiency. to the coil Advanced Sound Hood to muffle noise from operation. COMPRESSOR PROTECTION—Each scroll compressor Model 597C Energy-Efficient Air Conditioners incorporate inno- motor is protected with internal temperature and current-sensi- vative scroll compressor technology to provide quiet, reliable tive overloads For improved serviceability, each compressor is cooling performance Built into these units are the features most equipped with a compressor terminal plug. desired by homeowners today including SEER ratings up to 14.0 SOUND HOOD—A thick, sound dampening material wrapped when combined with specific Bryant equipment. All models are around the compressor muffles operational noise. listed with UL, c-UL, ARI, CEC, and CSA-EEV The 597C meets LIMITED WARRANTY—Standard 1-year warranty on parts, the Energy Star®guidelines for energy efficiency. with an additional 9-year warranty on compressor ELEC RR CAL INSP CT60M REGURED Form No. PDS 597C.18.8 NOTES: 1.Allow 30 in.clearance to service end of unit,48 in above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow - 2.Minimum outdoor operating ambient in cooling mode is 55°F(unless low-ambient control is used) max 125°F. 3.Series designation is the'14th position of the unit model number. 4.Center of gravity Q. 3/8-IN DIA TIEDOWN KNOCKOUTS_ (2)PLACES IN BASEPAN FIELD POWER SUPPLY CONN 7/8-IN DIA L HOLE WITH 1 1/8-IN DIA KNOCKOUT AIR IN AIR DISCHARGE AND 1 3/8-IN DIA KNOCKOUT B AIR DISCHARGE • ° O FIELD CONTROL o K SUPPLY CONN ACCESS � ° D 7/8-IN DIA HOLE ° PANEL AIR IN -► M H DIA VAPOR A - ° LINE CONN G ° + E 3/8-IN DIA LIQUID F. Q - © LINE CONN + 10 1h` m M Z ' 4 3116" co AIR DISCHARGE AIR IN 8 ahs o N 1 1/4 o 1 3/4" A97082 DIMENSIONS (IN.) UNIT UNIT DIMENSIONS MINIMUM MOUNTING SIZE SERIES A B C D E F G H K L M N PAD DIMENSIONS 018 F 33-13/16 22-1/2 26-3/16 4-1/8 7-1/8 21-15/16 28-3/8 5/8 9-1/4 17-3/8 13-1/2 2-3/8 20 x 27 024 F 27-13/16 30 33 5-1/16 9-11/16 15-15/16 22-3/8 5/8 16-1/2 20-3/8 11 2-15/16 26 x 32 030 F 33-13/16 30 33 5-1/16 9-11/16 21-15/16 28-3/8 3/4 16-1/2 20-3/8 13-1/2 2-15/16 26 x 32 036 F 1 33-13/16 30 33 5-1/16 9-11/16 21-15/16 28-3/8 3/4 16-1/2 20-3/8 13-1/2 2-15/16 26 x 32 042 F 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 16-1/2 20-3/8 15 2-15/16 26 x 32 048 G,F 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 16-1/2 20-3/8 15 2-15/16 26 x 32 060 F 39-13/16 30 33 5-1/16 9-11/16 27-15/16 34-3/8 7/8 16-1/2 20-3/8 15 2-15/16 26 x 32 RECOMMENDED TUBE DIAMETERS Liquid Tube Diameter(In.) VaporTube Diameter(In.) UNIT 0 to 50 Ft 0 to 50 Ft Long-Line Applications* SIZE Tube Length Long-Line Applications* Tube Length (Maximum Diameter) 018,024 5/8 3/4 030,036 3/8 3/8 3/4 7/8 042,048 7/8 1-1/8 060 1-1/8 1-1/8 *For tube sets between 50 and 175 ft,consult Residential Split System Long-Line Application Guideline CHECK-FLO-RATER®PISTON PISTON* UNIT SIZE-SERIES IDENTIFICATION NO. 018-F 55 024-F 61 030-F 67 036-F 76 042-F 82 048-G 90 048-F 93 060-F 101 *Piston listed Is for any approved non-capillary tube cod combination Piston Is shipped with outdoor unit and must be installed in an approved indoor cod CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) ' UNIT SIZE-SERIES REQUIRED SUBCOOLING(°F) 018-F 10 024-F 12 030-F 15 036-F 12 042-F 12 048-G,F 11 060-F 12 (Gor Oa�t`g Or, f ar�O,1 BSI APPROVALS ��• �� IS09001 •e• EN 29001 CUu S As an ENERGY STAR® a � BS 5750 PART 1 S g�' Partner,Bryant hANSI/ASOC 091 as 09001 P2g &Cooling Systemsms has CERTIFICATE NO FM 28768 determined that this product meets the CERTIFICATION APPLIES REGISTERED QUALITY SYSTEM ENERGY STAR® ONLY WHEN THE efficiency for energy COMPLETE SYSTEM CSA'f efficiency IS LISTED WITH ARI. -3- SPECIFICATIONS UNIT SIZE-SERIES 018-F 024-F 030-F 036-F 042-F 048-GIF 060-F Operating Weight(Lb) 1 149 1871 197 1 197 1 207 261 265 ELECTRICAL Unit Volts—Hertz—Phase 208/230-60-1 208/230--60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-1-60 208/230-1-60 Operating Voltage Range* 187-253 187-253 187-253 187-253 187-253 187-253 187-253 Compressor—Rated Load Amps 100 114 150 179 200 23 7/19 9 288 Locked Rotor Amps 41.0 56.0 725 88.0 1040 129 0/137 0 1690 Condenser Fan Motor—Full Load Amps 0.5 05 05 -1 1 1 1 1 1 14 Min Unit Ampacity for Wire Sizing 130 14.8 19.3 234 260 30 5/26 0 374 Min Wire Size(60°C Copper)AWGt 14 14 14 12 10 8/10 8 Min Wire Size(75°C Copper)AWGt 14 14 14 12 10 10 8 Max Wire Length(60°C)(Ft)$ 61 53 39 52 77 77 62 Max Wire Length(75°C)(Ft)$ 58 50 37 50 73 61 78 Max Branch Circuit Fuse Size(Amps)** 20 20 30 40 40 50/40 60 COMPRESSOR&REFRIGERANT Compressor •- Compressor—Manufacturer Copeland Type Scroll Temperature&Current Protection Internal Line Break Refrigerant— Type R-22 Amount @ 15 Ft ft, 425 525 625 61- 17 001 10 50 11 00 CONDENSER COIL Coil Face Area(Sq Ft) 109 122 152 152 7_18-37 - 18 3 183 Fins Per In—Rows—Circuits 25-1-2 1 25-1-2 1 25-1-3 25-1-3 25-1-4 20-2-5 20-2-6 Fan Motor—PSC Type,HP&RPM 1/15&800 1/5&825 1/4&1125 Volts—Hertz—Phase 208/230-60-1 Condenser Airflow(CFM) 1500 2000 2000 3000 3000 3000` 3300 OPTIONAL EQUIPMENT Support Feet KSASF0101AAA Coastal Filter KAACF0101SML KAACF0201MED Time Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1201AAA Start Assist—Capacitor/Relay Type KSAHS1501AAA IKSAHS1601AAA Start Assist—PTC Type KAACS0201PTC TXV(RPB) KAATX0201RPB KAATX0301RPB KAATX0401RPB I WTX0501RP13 KAATX0601RP6 KAATX0701RPB TXV(Hard Shutoff)$$ KSATX0601HSO KSATX0701 HSO Low-Pressure Switch KAALP0101 LPS High-Pressure Switch KSAH10101HPS Filter Drier P502-8083S(RCD) P502-8163S(RCD) Evaporator Freeze Thermostat*** KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0101 LLS Winter Start Control*** KAAWS0101AAA Low-Ambient Pressure Switch KSALA0201 R22 Low-Ambient Controller P251-0083(RCD) MotorMaster®Controlttt 32LT660004(RCD) Ball Bearing Fan Motor Not Available HC38GE231(RCD) HC40GE232 (RCD) Thermostat,Auto Changeover, Non-Programmable,°F/°C,' 1-Stage Heat,1-Stage Cool TSTATBBNAC01-B Thermostat,Auto Changeover, 7-Day Programmable,°F/°C, 1-Stage Heat,1-Stage Cool TSTATBBPAC01-B ThermidistatM Control— Programmable/Non-Programmable Thermostat with Humidity Control TSTATBBPRH01-B Builder's Thermostat,Manual Changeover, Non-Programmable,°F/°C, 1-Stage Heat,1-Stage Cool TSTATBBBAC01-B Outdoor Air Temperature Sensor TSTATXXSEN01-B Backplate for Builder's Thermostat TSTATXXBBP01 Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Thermostat Conversion Kit(4 to 5 wire) TSTATXXCNV10 See notes on page 5 —4— * Permissible limits of the voltage range at which the unit will operate satisfactorily Operation outside these limits may result in unit failure t If wire is applied at ambient greater than 30°C(86°F),consult Table 310-16 of the NEC(ANSI/NFPA 70) The ampacity of nonmetallic-sheathed cable(NM),trade name ROMEX,shall be that of 60°C(140°F)conductors,per the NEC(ANSI/NFPA 70)Article 336-26 If other than uncoated(non-plated),60 or 75°C(140 or 167°F)insulation,copper wire(solid wire for 10 AWG and smaller,stranded wire for larger than 10 AWG)is used,consult applicable tables of the NEC(ANSI/NFPA 70) $ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2% ** Time-delay fuse or circuit breaker tt Charge quantity is for 15 ft of interconnecting tubing For tubing lengths longer than 15 ft,add 0 6 oz of refrigerant per ft of tube length in excess of 15 ft $$ Do not use hard shutoff TXV with LSV *** See low-ambient controller Installation Instructions for application ttt Fan motor with ball bearings required NOTES: 1 All motors/compressors contain internal overload protection 2 Copper wire must be used from service disconnect to unit 3 Control circuit is 24v on all units and requires external power source -5- ACCESSORY USAGE GUIDELINE REQUIRED FOR REQUIRED FOR REQUIRED FOR LOW-AMBIENT LONG-LINE SEA COAST APPLICATIONS APPLICATIONS* APPLICATIONS ACCESSORY (Below 55°F) (Over 50 Ft (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yest No No Accumulator No No No Compressor Start Assist Yes Yes No Capacitor and Relay Low Ambient Controller, MotorMaster®Control, Yes No No or Low-Ambient Pressure Switch Wind Baffle See Low-Ambient Instructions No No Coastal Filter No No Yes Support Feet Recommended No Recommended Liquid-Line Solenoid Valve See Long-Line or No Application No Hard ShutoffTXV Guideline Ball Bearing Fan Motor Yes$ No No * For tubing line sets between 50 and 175 ft,refer to the Residential Split-System Long-Line Application Guideline t Only when low-pressure switch is used t Required for Low-Ambient Controller(full modulation feature)and MotorMaster Control only ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) 1 Ball Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication SUGGESTED USE Required on all units where Low-Ambient Controller(full modulation feature)or MotorMaster®Control has been added 2 Coastal Filter A mesh screen inserted under the top cover and inside the base pan to protect the condenser cod from salt damage without restricting airflow SUGGESTED USE In geographic areas where salt damage could occur 3 Compressor Start Assist—Capacitor/Relay Type Start capacitor and start relay gives"hard"boost to compressor motor at each start-up SUGGESTED USE Installations where interconnecting tube length exceeds 50 ft Installations where outdoor design temperature exceeds 105°F(40 6"C). Replacement installations with hard shutoff expansion valve on indoor coil Installations where Liquid-Line Solenoid Valve has been added 4 Compressor Start Assist—PTC Type Solid state electrical device which gives a"soft"boost to compressor motor at each start-up SUGGESTED USE Installations with marginal power supply Replacement installations with rapid pressure balance(RPB)expansion valve on indoor cod. 5 Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles Improves compressor lubrication on restart and minimizes chance of refrigerant slugging.May or may not include a thermostat control. SUGGESTED USE- When interconnecting tube length exceeds 50 ft When unit will be operated below 55°F(12 8"C)outdoor air temperature Use with Low-Ambient Controller All commercial installations 6 Cycle Protector Solid state timing device which prevents compressor rapid recycling.Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason,including normal room thermostat cycling SUGGESTED USE Installations in areas where power interruptions are frequent Where user is likely to"play"with the room thermostat All commercial installations Installations where interconnecting tube length exceeds 50 ft High-rise applications 7 Evaporator Freeze Thermostat An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions SUGGESTED USE- All units where Winter Start Control has been added. 8 Filter Drier A device for removing contaminants from refrigerant circulating in an air conditioner.1-direction flow. SUGGESTED USE All split system air conditioners 9 High-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit Cycles compressor off if refrigerant pressure rises to 400 t 10 prig and resets at 298 t 20 psig.Provides protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling, Cycle Protector can be used with this switch SUGGESTED USE. Installations exposed to very"dirty"outdoor air Installations where condenser inlet air temperature exceeds 125"F(51 7"C) 10. Liquid-Line Solenoid Valve(LSV) An electrically operated shutoff valve to be installed at the outdoor or indoor unit(depending on tubing configuration)and which stops and starts refrigerant liquid flow in response to compressor operation.Maintains a column of refrigerant liquid ready for action at next compressor operation cycle. NOTE:Compressor Start Assist—Capacitor/Relay Type must also be used Do not use with hard shutoff TXV SUGGESTED USE For improved system performance in air conditioners for certain combinations of indoor and outdoor units Refer to ARI Unitary Directory In certain long line-applications Refer to Residential Split System Long-Line Application Guideline —6— ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)Continued 11. Low-Ambient Controller Head pressure controller is a cycle control device activated by a temperature sensor mounted on a header tube of the outdoor coil It is designed to cycle the outdoor fan motor in order to maintain condensing temperature within normal operating limits(approximately 100°F high and 60°F low) The control will maintain working head pressure at low-ambient temperatures down to 0°F when properly installed SUGGESTED USE Cooling operation at outdoor temperatures below 55°F(12 8°C) 12 Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve.It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits(approximately 100 psig to 225 prig) The control maintains working head pressure at low-ambient temperatures down to 0°F when properly installed - SUGGESTED USE Cooling operation at outdoor temperatures below 55°F(12 8°C) 13 Low-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on liquid side of refrigerant circuit Cycles compressor off if refrigerant charge is lost To prevent rapid compressor recycling,Cycle Protector can be used with this switch SUGGESTED USE Where indoor coil is exposed to"dirty"air All commercial installations 14 MotorMaster@ Control A fan speed control device activated by a temperature sensor Designed to control condenser fan motor speed in response to the saturated,condensing temperature during operation in cooling mode only For outdoor temperatures down to–20°F,it maintains condensing temperature at 100°F f 10°F. SUGGESTED USE Cooling operation at outdoor temperatures below 55°F All commercial installations 15 Outdoor Air Temperature Sensor A device that allows the temperature at a remote location(outdoors)to be displayed at the thermostat SUGGESTED USE All corporate programmable thermostats 16 Support Feet Four stick-on plastic feet which raise the unit 4 in above the mounting pad This allows sand,dirt,and other debris to be flushed from the umt base minimizing corrosion SUGGESTED USE Coastal installations Windy areas or where debris is normally circulating Rooftop installations For improved sound rating 17 Thermostatic Expansion Valve(TXV) A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator Kit includes valve,adapter tubes,and external equalizer tube Both hard shutoff and RPB type valves are available Do not use hard shutoff TXV with Liquid-Line Solenoid Valve SUGGESTED USE- For improved system performance in cooling mode for certain combinations of indoor and outdoor units Refer to ARI Unitary Directory. Required for use on all zoning systems 18 Time-Delay Relay An SPST delay relay which briefly continued operation of the indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USE- For improved efficiency ratings for certain combinations of indoor and outdoor units Refer to ARI Unitary Directory Required for use on all zoning systems 19 Winter Start Control An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for,coolmg operation under low-load conditions SUGGESTED USE All air conditioners where Low-Ambient Controller has been added SOUND POWER(dBA) SOUND OCTAVE BAND CENTER FREQUENCY(Hz) UNIT LEVEL SIZE (dBA) 125 250 500 1000 2000 4000 8000 018 68 500 565 61 0 635 590 545 45.5 024 70 550 61 5 625 645 61 0 550 490 030 72 550 580 61 5 635 625 565 51 5 036 74 565 635 680 700 630 575 520 042 74 565 605 645 675 61 5 580 530 048 74 560 61 0 670 675 660 630 565 060 76 635 660 690 690 665 640 565 —7— COMBINATION RATINGS SEER FACTORY- BRYANT GAS ACCESSORY UNIT SUPPLIED FURNACE OR SIZE- INDOOR TOTAL CAP. ENHANCE- STANDARD ACCESSORY SERIES SECTION BTUH MENT RATING TDRt TXV$ LLS EER CK5BA018* 17,400 NONE - 1200 12.00 1200 11 05 CC5A/CD5AA018 17,400 NONE - 1200 1200 1200 1105 CC5A/CD5AA024 17,800 NONE - 1220 1220 1220 1125 CC5A/CD5AW024 17,800 NONE - 1220 1220 1220 1125 CE3AA024 17,600 NONE - 1220 1220 12.20 1125 CK36A024 17,800 NONE - 1220 1220 12.20 1125 CK5A/CK5BA024 17,800 NONE - 1220 1220 1220 11.25 CK5A/CK5BW024 17,800 NONE - 1220 1220 1220 1125 F(A,B)4AN(F,C)018 17,000 TDR 1200 - 1200 - 1095 F(A,B)4AN(F,C)024 17,600 TDR 1250 - 1250 - 1145 FC4BNF024 17,600 TDR&TXV 1250 - - - 1145 FF1(B,C,D)NA018 17,000 TDR 1220 - 1220 - 1130 FF1(B,C,D)NA024 17,600 TDR 1220 - 1220 - 1130 FG3AAA024 17,400 NONE - 1200 1200 12,00 1105 018-F FK4CNF001 18,000 TDR&TXV 1400 - - - 1285 FK4CNF002 18,000 TDR&TXV 1400 - - - 1295 COILS+333(B;J)AV036060 VARIABLE SPEED"FURNACE, ":'„•„ CC5A/CD5AA018 17,000 TDR 1350 - 1350 - 1230 CC5A/CD5AA024 17,600 TDR 1400 - 14.00 - 1265 CK313A024 17,600 TDR 1400 - 1400 - 1265 CK5A/CK5BA018 17,000 TDR 1350 - 1350 - 12.30 CKSA/CK5BA024 17,600 TDR 14.00 - 1400 - 1265 "COILS+355MAV042060VARIABLE SPEED'FURNACE CC5A/CD5AW024 17,600 TDR 13 50 - 1350 - 1245 CK5A/CK5BW024 17,600 TDR 1350 - 1350 - 1245 COILS.+355MAV042080 VARIABLE:SPEED FURNACE, CC5A/CD5AW024 17,600 TDR 1350 - 1350 - 1255 CK5A/CK5BW024 17,600 TDR 1350 - 1350 - 12.55 CC5A/CD5AA024* 23,000 NONE - 1200 1200 1200 10.85 CC5A/CD5AA030 23,200 NONE - 1220 1220 1220 1095 CC5A/CD5AW024 23,000 NONE - 1200 12.00 1200 1085 CC5A/CD5AW030 23,200 NONE - 1220 1220 1220 10.95 CE3AA024 23,000 NONE - 1200 1200 1200 1095 CE3AA030 23,200 NONE - 1220 1220 1220 1110 CF5AA024 23,000 NONE - 1200 1200 1200 1095 CK36A024 23,000 NONE - 1200 1200 1200 1085 CK3BA030 23,200 NONE - 1220 1220 1220 1105 CK5A/CK5BA024 23,000 NONE - 1200 1200 1200 1085 CK5A/CK5BA030 23,200 NONE - 12.20 1220 1220 1105 CK5A/CK5BW024 23,000 NONE - 1200 1200 1200 1085 CK5A/CK5BW030 23,200 NONE - 1220 1220 1220 1105 F(A,B)4ANF024 23,200 TDR 1200 - 1200 - 10.95 F(A,B)4ANF030 23,600 TDR 1220 - 1220 - 11 25 FC4BNF024 23,200 TDR&TXV 1200 - - - 1095 FC413NF030 23,600 TDR&TXV 12.20 - - - 1125 FF1(B,C,D)NA024 23,000 TDR 1200 - 1200 - 10.85 FF1(B,C,D)NA030 23,600 TDR 1220 - 1220 - 11.10 FG3AAA024 22,800 NONE - 1180 11 80 1180 1070 FK4BNF001 23,400 TDR&TXV 1350 - - - 1235 FK413NF002 23,600 TDR&TXV 1350 - - - 1250 FK4BNF003 23,600 TDR&TXV 1400 - - - 1280 FK413NF004 24,000 TDR&TXV 14.00 - - - 1280 FK4CNF001 23,400 TDR&TXV 1350 - - - 1235 FK4CNF002 23,600 TDR&TXV 13.50 - - - 12.50 024-F FK4CNF003 23,600 TDR&TXV 1400 - - - 1280 Y COILS+'333(B;J)AV03606.0 VARIABLE SPEED"FURNACE CC5A/CD5AA030 23,600 TDR 1350 - 1350 - 1225 CE3AA030 23,600 TDR 13.50 - 1350 - 1235 CK36A024 23,000 TDR 1300 - 1300 - 1190 CK36A030 23,200 TDR 13.50 - 1350 - 1215 CK5A/CK5BA024 23,000 TDR 1300 - 13.00 - 1190 CK5A/CK5BA030 23,200 TDR 1350 - 1350 - 1215 CK5A/CK5BW030 23,200 TDR 1350 - 1350 - 1215 COILS•+355MAV042040.VARIABLE SPEED FURNACE CC5A/CD5AA024 23,200 TDR 1300 - 1300 - 1190 CC5A/CD5AA030 23,600 TDR 1350 - 1350 - 1220 CK3BA024 23,000 TDR 1300 - 1300 - 1175 CK3BA030 23,200 TDR 1300 - 1300 - 1205 CK5A/CK5BW030 23,200 TDR 1300 - 1300 - 12.05 COIL'S+'35.5MAV042060.VARIABLE;SPEED FURNACE CC5A/CD5AA024 23,200 TDR 1300 - 1300 - 1190 CC5A/CD5AA030 23,600 TDR 1350 - 1350 - 1220 CK36A024 23,000 TDR 1300 - 1300 - 1175 CK3BA030 23,200 TDR 1300 - 1300 - 1200 CK5A/CK5BW024 23,000 TDR 13.00 - 1300 - 1175 CK5A/CK5BW030 23,200 TDR 1300 - 1300 - 1200 'COILS+'•355MAV042080 VARIABLE SPEED'FURNACE CC5A/CD5AA024 23,200 TDR 13.00 - 13 00 - 1190 CC5A/CD5AA030 23,600 TDR 13 50 - 1350 - 12 20 See notes on page 13 -8- COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS ACCESSORY UNIT SUPPLIED FURNACE OR SIZE- INDOOR TOTAL CAP. ENHANCE- STANDARD ACCESSORY SERIES SECTION BTUH MENT RATING TDRt TXV* LLS EER CK3BA024 23,000 TDR 1300 - 1300 - 12.00 024-F CK3BA030 23,200 TDR 1350 - 1350 - 1225 CK5A/CK5BW024 23,000 TDR 1300 - 1300 - 1200 CK5A/CK5BW030 23,200 TDR 1350 - 1350 - 1225 CC5A/CD5AA030* 29,000 NONE - 1200 1200 1200 1055 CC5A/CD5AA036 29,600 NONE - 1250 1250 1250 1090 CC5A/CD5AW030 29,000 NONE - 1200 1200 1200 10.55 CD5AW036 29,600 NONE - 12.50 1250 1250 1090 CE3AA030 29,000 NONE - 1200 1200 1200 1065 CE3AA036 29,600 NONE - 1220 12.20 1220 1080 CF5AA036 29,600 NONE - 1250 1250 1250 1090 CK36A030 29,000 NONE - 1200 1200 1200 1060 CK3BA036 29,600 NONE - 1250 1250 1250 1095 CK5A/CK5BA030 29,000 NONE - 1200 1200 1200 1060 CK5A/CK5BA036 29,600 NONE - 1250 12.50 1250 1095 CK5A/CK5BN036 27,600 NONE - 1250 1250 1250 1095 CK5A/CK5BW030 29,000 NONE - 1200 1200 1200 1060 CK5A/CK5BW036 29,600 NONE - 1250 1250 1250 1095 F(A,B)4ANF030 29,200 TDR 1200 - 1200 - 1070 F(A,B)4ANF036 29,600 TDR 12.00 - 1200 - 1065 FC4BNF030 29,200 TDR&TXV 1200 - - - 10.70 FC46NF036 29,600 TDR&TXV 12.00 - - - 1065 FF1(B,C,D)NA030 29,600 TDR 1200 - 1200 - 1070 FG3AAA036 29,400 NONE - 1200 1200 1200 1070 FK4BNF001 29,600 TDR&TXV 1300 - - - 11 45 FK413NF002 29,600 TDR&TXV 1340 - - - 1155 FK4BNF003 30,000 TDR&TXV 1380 - - - 1210 FK4BNF004 30,200 TDR&TXV 1400 - - - 12.00 FK4CNF001 29,600 TOR&TXV 13.00 - - - 1145 FK4CNF002 29,600 TDR&TXV 1340 - - - 1155 FK4CNF003 30,000 1 TDR&TXV 1380 - - - 1210 COILS+'333(B;J)AV036060 VARIABLE SPEED FURNACE CC5A/CD5A036 30,000 TDR 1350 - 1350 - 12.05 CE3AA036 29,800 TDR 1350 - 1350 - 11 80 CK3BA030 29,000 TDR 1300 - 13.00 - 11 30 CK313A036 29,600 TDR 1350 - 1350 - 11 85 CK5A/CK5BA030 29,000 TDR 1300 - 1300 - 11 30 CK5A/CK5BA036 29,600 TDR 1350 - 1350 - 11 85 CK5A/CK5BN036 27,600 TDR 1300 - 1300 - 1170 CK5A/CK5BW030 29,000 TDR 1300 - 1300 - 1130 COILS+333(B;J)AV048080 VARIABLE SPEED,FURNACE;' 030-F CC5A/CD5AA036 30,000 TDR 1350 - 1350 - 12.05 CE3AA036 29,800 TDR 1350 - 1350 - 1180 CK36A030 29,000 TDR 1300 - 1300 - 1150 CK36A036 29,600 TDR 1350 - 1350 - 1200 CK5A/CK5BW030 29,000 TDR 1300 - 1300 - 1150 CK5A/CK5BW036 29,600 TDR 1350 - 1350 - 1200 .;w:COILS+,356MAV042040 VARIABLE SPEED FURNACE'' ,', CC5A/CD5AA030 29,600 TDR 1300 - 1300 - 11 45 CC5A/CD5AA036 30,000 TDR 1350 - 1350 - 1195 CK3BA030 29,000 TDR 1250 - 1250 - 11 10 'CK3BA036 29,600 TDR 1300 - 1300 - 11 65 CK5AlCK513W030 29,000 TDR 1250 - 1250 - 1110 CK5A/CK5BW036 29,600 TDR 13 00 - 1300 - 1165 'COILS+355MAV042060 VARIABLE,SPEED FURNACE ' CC5A/CD5AA030 29,600 TDR 1300 - 1300 - 1145 CC5A/CD5AA036 30,000 TDR 1350 - 1350 - 11 95 CK3BA030 29,000 TDR 1250 - 1250 - 11 10 CK3BA036 29,600 TDR 1300 - 1300 - 11 65 CK5A/CK5BA036 29,600 TDR 1300 - 1300 - 1165 CKSA/CK5BW030 29,000 TDR 1250 - 1250 - 1110 COILS+355MAV042080 VARIABLE'SPEED'FURNACE, CC5A/CD5AA030 29,600 TDR 1300 - 13.00 - 11.45 CC5A/CD5AA036 30,000 TDR 1350 - 1350 - 1195 CK36A030 29,000 TDR 1250 - 1250 - 11 20 CK36A036 29,600 TDR 1300 - 1300 11 75 CK5A/CK5BW030 29,000 TDR 1250 - 12.50 1120 CK5A/CK5BW036 29,600 TDR 1300 - 13.00 - 11 75 COILS+356MAV060080'VARIABLE SPEED FURNACE , CK3BA030 29,000 TDR 1250 - 12.50 - 11 05 CK3BA036 29,600 TDR 1300 - 13 00 - 11 60 CK5A/CK5BW030 29,000 TDR 12.50 - 12 50 - 1105 CK5A/CK5BW036 29,600 TDR "I'll - 13 00 - 1160 'COILS'+355MAV060100 VARIABLE SPEED FURNACE. CK36A030 29,000 TDR 130 0 - 13.00 - 11 45 CK3BA036 29,600 TDR 1350 - 1350 - 1200 CK5A/CK5BW030 29,000 TDR 1300 - 1300 - 1145 CK5A/CK5BW036 29,600 TDR 1350 - 1350 - 1200 See notes on page 13, -9- COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS ACCESSORY UNIT SUPPLIED FURNACE OR SIZE- INDOOR TOTAL CAP. ENHANCE- STANDARD ACCESSORY SERIES SECTION BTUH MENT RATING TDRt TXV$ LLS EER COILS+'355MAV060120•VARIABLE�SPEED'FURNACE .E 030-F CK3BA030 29,000 TDR 1300 - 1300 - 1140 CK3BA036 29,600 TDR 1350 - 13.50 - 1195 CK5A/CK5BW036 29,600 TDR 1350 - 1350 - 11.95 CC5A/CD5AA036* 35,000 NONE - 1200 12.00 1200 1075 CC5A/CD5AA042 35,000 NONE - 1200 1200 1200 1075 CC5A/CD5AW042 35,000 NONE - 1200 1200 1200 1065 CD5AW036 35,000 NONE - 1200 1200 1200 10.75 CE3AA036 34,800 NONE - 1200 1200 1200 1060 CE3AA042 35,400 NONE - 12.20 1220 1220 1080 CF5AA036 35,200 NONE - 1200 1200 12.00 1070 CK3BA036 35,000 NONE - 1200 1200 1200 1075 CK3BA042 35,000 NONE - 1200 1200 1200 1075 CK5A/CK5BA036 35,000 NONE - 1200 12.00 1200 1075 CK5A/CK5BA042 35,000 NONE - 1200 1200 1200 1075 CK5A/CK5BN036 33,000 NONE - 1150 1150 1150 1050 CK5A/CK5BN042 34,000 NONE - 1200 1200 1200 1075 CK5A/CK5BW036 35,000 NONE - 1200 1200 1200 1075 F(A,B)4ANF036 35,000 TDR 1200 - 1200 - 1065 F(A,B)4AN(F,B)042 35,400 TDR 1200 - 1200 - 1070 FC46NB054 36,000 TDR&TXV 1300 - - - 11 45 FC46NF036 35,000 TDR&TXV 1200 - - - 1065 FC4BN(F,B)042 35,400 TDR&TXV 1200 - - - 1070 FG3AAA036 34,600 NONE - 1180 11 80 1180 1050 FK4BNB005 36,000 TDR&TXV 1400 - - - 1210 FK413NB006 36,000 TDR&TXV 1400 - - - 1235 FK4BNF001 35,000 TDR&TXV 1220 - - - 10.95 FK4BNF002 35,000 TDR&TXV 1250 - - - 11 00 FK4BNF003 35,400 TDR&TXV 1300 - - - 11.60 FK4BNF004 35,400 TDR&TXV 1300 - - - 11,40 FK4CNB006 36,000 TDR&TXV 1400 - - - 12.35 FK4CNF001 35,000 TDR&TXV 1220 - - - 1095 FK4CNF002 35,000 TDR&TXV 1250 - - - 1100 FK4CNF003 35,400 TDR&TXV 1300 - - - 1160 FK4CNF005 36,000 1 TDR&TXV 1 14.00 - - - 1210 COILS+,•333(B,J)AV036060VARIABLE,SPEED.FURNACE • ' , CC5A/CD5AA042 35,400 TDR 1300 - 1300 - 1165 CE3AA042 35,400 TDR 1300 - 1300 - 1170 CK313A036 35,000 TDR 1300 - 13.00 - 1145 CK3BA042 35,000 TDR 1300 - 1300 - 11 35 CK5A/CK5BA036 35,000 TDR 1300 - 1300 - 1145 CK5A/CK5BN036 33,000 TDR 1250 - 1250 - 1165 COILS•+333(B,J)AV048080 VARIABLE SPEED FURNACE 036-F CC5A/CD5AA042 35,400 TDR 1300 - 13 00 - 11 65 CE3AA042 35,400 TDR 1300 - 1300 - 11.70 CK3BA036 35,000 TDR 1300 - 13.00 - 1175 CK3BA042 35,000 TDR 1300 - 13.00 - 1155 CK5A/CK5BA042 35,000 TDR 1300 - 13.00 - 1155 CK5A/CK5BW036 35,000 TDR 1300 - 1300 - 1175 COILS+333(B,J)AV•060100 VARIABLE SPEED'FURNACE, CC5A/CD5AA042 35,400 TDR 1300 - 13 00 - 1165 CE3AA042 35,400 TDR 13.00 - 1300 - 1170 CK36AO36 35,000 TDR 1300 - 1300 - 11.75 CK3BA042 35,000 TDR 1300 - 1300 - 11.80 CK5A/CK5BA042 35,000 TDR 1300 - 13.00 - 1180 CK5A/CK5BW036 35,000 TDR 1300 - 1300 - 1175 ?, COILS+•333(B,J)AV060420 VARIABLE SPEED FURNACE r. CC5A/CD5AA042 35,400 TDR 1300 - 1300 - 11 65 CE3AA042 35,400 TDR 1300 - 1300 - 11.70 CK3BA042 35,000 TDR 1300 - 13.00 - 11 75 CK5A/CK5BA042 35,000 TDR 1300 - 1300 - 1175 CK5A/CK5BW036 35,000 TDR 1300 - 1300 - 1165 COIL'S•+355MAV042040 VARIABLgSPEED FURNACE,,`, CC5A/CD5AA036 35,200 TDR 1300 - 13.00 - 1160 CC5A/CD5AA042 35,200 TDR 1300 - 1300 - 1170 CK3BA036 35,000 TDR 1250 - 12.50 - 11 35 CK3BA042 35,000 TDR 1300 - 1300 - 1145 CK5A/CK5BA042 35,000 TDR 1300 - 1300 - 1145 CK5A/CK5BW036 35,000 TDR 1250 - 1250 - 1135 COILS+155MAV042060 VARIABLE SPEED FURNAC& CC5A/CD5AA036 35,200 TDR 1300 - 1300 - 1160 CC5A/CD5AA042 35,200 TDR 1300 - 1300 - 1170 CK3BA036 35,000 TDR 1250 - 12.50 - 11 35 CK3BA042 35,000 TDR 1300 - 1300 - 11.40 CK5A/CK5BA036 35,000 TDR 1250 - 1250 - 1135 CK5A/CK5BN042 34,000 TDR 1300 - 1300 - 11.40 COILS;*355MAV042080VARIABL'E SPEED FURNACE,,'• CC5A/CD5AA036 35,200 TDR 13.00 - 1300 - 1160 CC5A/CD5AA042 35,200 TDR 1300 - 13.00 - 1170 CK3BA036 35,000 TDR 1250 - 1250 - 1145 CK3BA042 35,000 TDR 1300 - 1300 - 1150 CK5A/CK5BA042 35,000 TDR 1300 - 1300 - 11.50 CK5A/CK5BW036 35,000 TDR 1250 - 1250 - 11 45 See notes on page 13 -10- COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS ACCESSORY UNIT SUPPLIED FURNACE OR SIZE- INDOOR TOTAL CAP. ENHANCE- STANDARD ACCESSORY SERIES SECTION BTUH MENT RATING TDRt TXV$ LLS EER Y COILS-t,366MAV060080 VARIABLE SPEED,FURNACE , CK3BA036 35,000 TDR 12 50 - 1250 - 1130 CK3BA042 35,000 TDR 1300 - 1300 - 1140 CK5A/CK5BA042 35,000 TDR 1300 - 1300 - 11.40 CK5A/CK5BW036 35,000 TDR 1250 - 1250 - 11.30 ;• ' COILS•+'355MAV060100 VARIABLE SPEED FURNACE. ;, . . „ •, ,; 036-F CC5A/CD5AA036 35,200 TDR 1300 - 1300 - 1160 CC5A/CD5AA042 35,200 TDR 1300 - 1300 - 11.70 CK36A036 35,000 TDR 1300 - 1300 - 1165 CK36A042 35,000 TDR 1300 - 1300 - 1165 CK5A/CK5BA042 35,000 TDR 1300 - 1300 - 11 65 CK5A/CK5BW036 35,000 TDR 1300 - 13.00 - 1165 COILS+355MAV060120,VARIABLESPEED FURNACE', CK5A/CK5BA042 35,000 TDR 1300 - 1300 - 1165 CK5A/CK5BW036 35,000 TDR 1300 - 13.00 - 1160 CC5A/CD5AA042* 41,000 NONE - 1200 12.00 1200 10 65 CC5A/CD5AC048 40,500 NONE - 1200 1200 1200 10 55 CC5A/CD5AW042 41,000 NONE - 1200 1200 1200 1055 CC5A/CD5AW048 41,000 NONE - 1220 1220 1220 1065 CD5AA048 41,000 NONE - 1220 1220 1220 1065 CE3AA042 41,000 NONE - 1200 1200 12.00 10.70 CE3AA048 41,500 NONE - 1220 1220 1220 1075 CF5AA048 41,500 NONE - 1220 1220 1220 1070 CK3BA042 41,000 NONE - 1200 1200 12.00 1065 CK3BA048 41,000 NONE - 1220 1220 1220 1070 CK5A/CK5BA042 41,000 NONE - 1200 1200 1200 1065 CK5A/CK5BA048 41,000 NONE - 1220 12.20 1220 1070 CK5A/CK5BN042 40,000 NONE - 1200 12.00 1200 1065 CK5A/CK5BN048 40,000 NONE - 1220 1220 1220 1070 CK5A/CK5BW048 41,000 NONE - 1220 1220 1220 10.70 F(A,B)4AN(F,B)042 41,000 TDR 1200 - 1200 - 1050 F(A,B)4AN(F,B)048 41,500 TDR 1220 - 1220 - 1070 FC4BN(F,B)042 41,000 TDR&TXV 1200 - - - 1050 FC4BN(F,B)048 41,500 TDR&TXV 1220 - - - 1070 FC46NB054 43,000 TDR&TXV 1300 - - - 1140 FG3AAA048 41,000 NONE - 1220 12.20 1220 1065 FK4BN13005 42,000 TDR&TXV 1350 - - - 11.75 FK413NI3006 43,000 TDR&TXV 1400 - - - 1210 FK4BNF003 41,500 TDR&TXV 13.00 - - - 1130 FK4CNB006 43,000 TDR&TXV 1400 - - - 1210 FK4CNF003 41,500 TDR&TXV 1300 - - - 1130 FK4CNF005 42,000 1 TDR&TXV 1 1350 - - - 1175 COILS+333(B,J)AV048080 VARIABLE SPEED,FURNACE CD5AA048 41,000 TDR 1350 - 1350 - 11.70 CE3AA048 41,000 TDR 1340 - 1340 - 11 55 042-F CK36AO42 41,000 TDR 1250 - 1250 - 11 20 CK3BA048 41,000 TDR 1300 - 1300 - 1130 CK5A/CK5BA042 41,000 TDR 1250 - 1250 - 1120 CK5A/CK5BA048 41,000 TDR 13.00 - 1300 - 1130 COILS+333(B,J)AV060100 VARIABLE SPEED-FURNACE CD5AA048 41,000 TDR 1350 - 1350 - 1170 CE3AA048 41,000 TDR 1340 - 1340 - 11.55 CK36A042 41,000 TDR 13.00 - 1300 - 11.45 CK38A048 41,000 TDR 1300 - 1300 - 1160 CK5A/CK5BA042 41,000 TDR 1300 - 13.00 - 1145 CK5A/CK5BW048 41,000 TDR 1300 - 1300 1160 " "•COILS,+33$(B;J)AV060120 VARIABLE.SPEED FURNACE CD5AA048 41,000 TDR 1350 - 1350 - 1170 CE3AA048 41,000 TDR 1340 - 1340 - 1155 CK3BA042 41,000 TDR 1300 - 1300 - 11.45 CK3BA048 41,000 TDR 1300 - 1300 - 11 60 CK5A/CK5BA042 41,000 TDR 1300 - 1300 - 11 45 CK5A/CK5BW048 41,000 TDR 1300 - 1300 - 1160 ` „W:COILS+355MAV042060 VARIABLE•SPEED FURNACE " CK3BA042 40,500 TDR 1250 - 1250 - 1100 CK3BA048 41,000 TDR 1250 - 1250 - 11 15 CK5A/CK5BN042 40,000 TDR 1250 - 1250 - 1100 CK5A/CK5BN048 40,000 TDR 1250 - 1250 - 11.05 COILS,+355MAV042080 VARIABLE SPEED FURNACE, ` CC5A/CD5AA042 41,000 TDR 1300 - 1300 - 1150 CD5AA048 41,000 TDR 1350 - 1350 - 1165 CK3BA042 40,500 TDR 1250 - 1250 - 11 15 CK3BA048 41,000 TDR 1250 - 1250 - 11 15 CK5A/CK5BA042 40,500 TDR 1250 - 1250 - 11 15 CK5A/CK5BA048 41,000 TDR 1250 - 1250 - 11 15 See notes on page 13 -11- COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS ACCESSORY UNIT SUPPLIED FURNACE OR SIZE- INDOOR TOTAL CAP. ENHANCE- STANDARD ACCESSORY SERIES SECTION BTUH MENT RATING TDRt TXV* LLS EER COILS',+355MAV060080"VARIABLE SPEED FURNACE,"''.' . 77, CK313AO42 40,500 TDR 1250 - 12 50 - 11 00 CK3BA048 41,000 TDR 12 50 - 12 50 - 11 15 CK5A/CK5BA042 40,500 TDR 12 50 - 125 - 1100 CK5A/CK5BA048 41,000 TDR 1250 - 12 50 - 1115 COILS+355MAV060100 VARIABLE SPEED FURNACE' ' CC5A/CD5AA042 41,000 TDR 1300 - 13.00 - 1150 042-F CD5AA048 41,000 TDR 1350 - 1350 - 11 65 CK3BA042 40,500 TDR 1300 - 1300 - 11 35 CK3BA048 41,000 TDR 1300 - 1300 - 11 50 CK5A/CK5BA042 40,500 TDR 1300 - 1300 - 11 35 CK5A/CK5BW048 41,000 TDR 1300 - 1300 - 11 50 COILS'+365 60120 VARIABLE.SPEED FURNACE'`"- CK3BA042 40,500 TDR 13 00 - 13 00 - 11 30 CK36AO48 41,000 TDR 1300 - 1300 - 1145 CK5A/CK5BA042 40,500 TDR 1300 - 1300 - 1130 CK5A/CK5BW048 41,000 TDR 1300 - 1300 - 1145 *CC5A/CD5AA060 48,000 NONE - 1200 1200 1200 1060 CC5A/CD5AC048 47,000 NONE - 1180 1180 11.80 1045 CC5A/CD5AW048 47,500 NONE - 1200 12.00 1200 1055 CC5A/CD5AW060 48,500 NONE - 1240 1240 1240 1085 CD5AA048 47,500 NONE - 1200 1200 1200 1055 CE3AA048 47,500 NONE - 12.00 1200 1200 1065 CE3AA060 48,000 NONE - 1240 1240 1240 1090 CF5AA048 47,500 NONE - 1200 1200 1200 1065 CK3BA048 47,500 NONE - 1200 1200 1200 10.60 CK3BA060 48,000 NONE - 1200 12.00 1200 1080 CK5A/CK5BA048 47,500 NONE - 1200 1200 1200 1060 CK5A/CK5BA060 48,000 NONE - 1200 1200 1200 1080 CK5A/CK5BN048 46,000 NONE - 1200 1200 1200 1060 ( CK5A/CK5BN060 48,000 NONE - 1200 12.00 1200 1100 CK5A/CK5BT048 47,500 NONE - 1200 1200 1200 1060 CK5A/CK5BT060 48,000 NONE - 1200 1200 1200 1080 CK5A/CK5BW048 47,500 NONE - 1200 1200 1200 1060 CK5A/CK5BX060 48,500 NONE - 1240 1240 1240 1100 F(A,B)4AN(F,B,C)048 47,500 TDR 1200 - 1200 - 1055 F(A,B)4AN(F,B,C)060 48,000 TDR 1210 - 1210 - 1060 FC4BN(F,B)048 47,500 TDR&TXV 1200 - - - 1055 FC4BN(F,B)060 48,000 TDR&TXV 1210 - - - 1060 FC413NB054 48,500 TDR&TXV 1250 - - - 1105 FC4BNB070 48,000 TDR&TXV 1220 - - - 1100 FG3AAA048 47,500 NONE - 1200 12.00 1200 1055 FG3AAA060 48,000 NONE - 1220 1220 12.20 1075 FK4CNB006 48,500 TDR 1350 - - - 1195 FK4CNF005 47,500 TDR 1320 - - - 1165 COU+333(B,J)AV048080VARIABLE"SMED.FURNACE' `" CC5A/CD5AC048 46,000 TDR 1200 - 12 00 - T1080 10 60 CD5AA048 47,000 TDR 1200 - 1200 - 10.75 048-G,F CK3BA048 47,000 TDR 1200 - 1200 - 10.80 CK5A/CK5BA048 47,000 TDR 1200 - 1200 - •COILS+333(6_,J)AV060100 VARIABLE•SPEED'EURNACE," CC5A/CD5AA060 47,000 TDR 1300 - 1300 - 11 30 CC5A/CD5AW048 47,000 TDR 1250 - 12 50 - 11 20 CC5A/CD5AW060 48,500 TDR 1300 - 13.00 - 1165 CK3BA060 47,000 TDR 1300 - 1300 - 11 60 CK5A/CK5BA060 47,000 TDR 1300 - 1300 - 11 60 CK5A/CK5BW048 47,000 TDR 1250 - 1250 - 1125 CK5A/CK5BX060 48,500 TDR 1300 - 13.00 - 11 85 COIL S':+"333(B,J)AV060120VARIABLE;SPEED'FURNACE ;t: CC5A/CD5AA060 47,000 TDR 1280 - 1280 - 11 20 CC5A/CD5AW048 47,000 TDR 1250 - 1250 - 1110 CC5A/CD5AW060 48,500 TDR 1300 - 1300 - 11 50 CK3BA048 47,000 TDR 1280 - 1280 - 1145 CK5A/CK5BA060 47,000 TDR 1280 - 1280 - 1145 CK5A/CK5BW048 47,000 TDR 1250 - 1250 - 11 15 CK5A/CK5BX060 48,500 TDR 1300 - 13.00 - 1170 COILS+355MAV042080 VARIABLE SPEED.FURNACE'. CD5AA048 47,000 TDR 12 00 - 1200 - 1070 CK3BA048 47,000 TDR 12.00 - 12 00 - 10 75 CK5A/CK5BA048 47,000 TDR 12 00 - 12 00 - 10 75 COILS+,355MAV060080VARIABLE SPEED FURNACE-,-,`,'' CC5A/CD5AA060 47,000 TDR 1200 - 12.00 - 10 65 CC5A/CD5AW060 48,000 TDR 1250 - 1250 - 1095 CD5AA048 47,000 TDR 1200 - 1200 - 1060 CK3BA048 47,000 TDR 1200 - 1200 - 1065 CK5A/CK5BA048 47,000 TDR 1200 - 1200 - 1065 CK5A/CK5BA060 47,000 TDR 12.00 - 1200 - 1090 CK5A/CK5BX060 48,000 TDR 1250 - 1250 - 11 15 See notes on page 13 -12- COMBINATION RATINGS Continued SEER FACTORY- BRYANT GAS ACCESSORY UNIT SUPPLIED FURNACE OR SIZE- INDOOR TOTAL CAP. ENHANCE- STANDARD ACCESSORY SERIES SECTION BTUH MENT RATING TDRt TXVt LLS EER COILS':+a355MAV060100 VARIABLE�,,SPEED.FURNACE CC5A/CD5AC048 46,000 TDR 1200 - 1200 - 1065 CC5A/CD5AW060 48,000 TDR 1280 - 12.80 - 1125 CD5AA048 47,000 TDR 1250 - 1250 - 10.90 CK313A048 47,000 TDR 1250 - 1250 - 1095 CK3BA060 47,000 TDR 12.50 - 1250 - 1120 CK5A/CK5BA048 47,000 TDR 1250 - 1250 - 1095 048-G,F CK5A/CK5BX060 48,000 TDR 1280 - 1280 - 1145 �. . COILS,+155MAV060120 VARIABLE SPEED'FURNACE r " CC5A/CD5AA060 47,000 TDR 1250 - 1250 - 1100 CC5A/CD5AW048 47,000 TDR 1250 - 1250 - 1090 CC5A/CD5AW060 48,000 TDR 1300 - 1300 - 1130 CK5A/CK5BA060 47,000 TDR 1250 - 1250 - 1125 CK5A/CK5BW048 47,000 TDR 1250 - 1250 - 1100 CK5A/CK5BX060 48,000 TDR 1300 - 1300 - 1150 CC5A/CD5AW060* 57,000 NONE - 1200 1200 1200 1030 CC5A/CD5AA060 55,000 NONE - 12.00 1200 1200 1020 CE3AA060 57,000 NONE - 1200 1200 1200 1040 CK3BA060 55,000 NONE - 1200 1200 1200 1045 CK5A/CK5BA060 55,000 NONE - 12.00 1200 1200 1035 CK5A/CK5BN060 55,000 NONE - 1200 1200 1200 10.55 CK5A/CK5BX060 57,000 NONE - 1200 12.00 1200 1045 F(A,B)4AN(F,B)060 57,000 TDR 1150 - 1150 - 9.95 F64ANI3070 58,000 TDR 1200 - 1200 - 1040 FC4BNB070 58,000 TDR&TXV 1200 - - - 1040 FC4BN(F,B)060 57,000 TDR&TXV 1150 - - - 995 060-F FG3AAA060 57,000 NONE - -1200 12.00 1200 1030 FK4BNB006 58,000 TDR&TXV 1250 - - - 1065 FK4CNI3006 58,000 TDR&TXV 1250 - - - 1065 COILS"+,333(B;J)AV060100VARIABLE SPEED,FURNACE CC5A/CD5AW060 57,000 TDR 12 50 - 12.50 - 10.75 CK313A060 55,500 TDR 1250 - 12.50 - 1090 CK5A/CK5BA060 55,500 TDR 1200 - 1200 - 1060 CK5A/CK5BX060 56,500 TDR 1260 - 1250 - 1090 COILS"+333(B,J)AV060120•VARIABLE•SPEED•FURNACE r CK3BA060 55,000 TDR 1250 - 1250 - 1080 y CK5A/CK5BA060 55,500 TDR 1200 - 1200 - 1,045 CK5A/CK5BX060 56,500 TDR 12 50 - 1250 - 10.80 * Tested combination t In most cases,only 1 method should be used to achieve TDR function Using more than 1 method in a system may cause degradation in performance Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR All Bryant furnaces are equipped with TDR except for the 394HAD t Based on computer simulation.Requires hard shutoff TXV EER -Energy Efficiency Ratio LLS -Liquid-Line Solenoid Valve SEER -Seasonal Energy Efficiency Ratio TDR -Time-Delay Relay TXV -Thermostatic Expansion Valve NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat.Supplemental electric heat is not included 2 Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for electric air conditioners Ratings for other com- binations are determined under DOE computer simulation procedures 3 Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature 4. Do not apply with capillary tube coils as performance and reliability are significantly affected. -13- DETAILED COOLING CAPACITIES* EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES°F AIR 85 95 105 115 125 Capacity Total Capacity Total Capacity . Total Capacity Total Capacity Total MBtuht System MBtuht System MBtuht System MBtuht System MBtuht System CFM EWB Total Sens$ Kw** Total Sens$ Kw** Total Sons* Kw** Total Sens$ Kw** Total I Sens$ Kw** 1 Outdoor SectionCI • •• Section 72 195 960 140 188 933 1 58 180 905 177 17.2 875 198 163 844 2.21 525 67 17.8 121 1 38 17.1 119 155 164 116 1.74 156 112 195 14.8 109 217 62 162 146 1.37 156 143 154 149 , 14.0 172 143 136 193 135 132 2.16 57 156 156 136 151 15.1 1.54 145 145 1.73 140 140 193 134 13.4 216 72 198 100 1 44 191 9.74 1 61 183 945 1.80 17.4 916 2.01 16.5 8.84 225 600 67 181 128 141 174 126 158 167 123 177 159 119 198 150 11.6 2.21 62 16.6 155 140 159 15.2 1 57 15.2 148 1 76 146 144 197 13.8 13.8 220 57 161 16.1 139 156 156 156 150 150 1.75 145 145 196 13.8 13.8 219 72 200 104 146 192 101 163 184 981 182 176 951 203 167 919 226 675 67 183 135 144 176 132 161 169 129 180 161 126 201 15.2 123 224 62 168 164 143 16.2 160 160 155 15.5 179 149 149 200 142 142 2.23 57 166 166 143 160 160 1.59 155 155 178 14.8 148 199 142 14.2 222 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling -Indoor Cooling Section Size Capacity Power Section Size I Capacity T Power CC5A/CD5AA 018 1 00 100 FK4CNF 001 1.03 091 024 102 100 002 103 0.91 CC5A/CD5AW 024 1.02 100 COILS+c333(B',`J)AV036060'VARIABLESPEEb'FURNACE'^, CE3AA 024 101 1,00 CC5A/CD5AA 018 098 090 CK313A 024 102 100 024 101 0.90 CK5A/CK5BA 018 1.00 1 00 CK3BA 024 1.01 090 024 1 02 1 00 CK5A/CK5BA 018 098 090 CK5A/CK5BW 024 1 02 1.00 024 1.01 090 F(A,B)4AN(F,C) 018 098 098 COILS'+.355MAV042060 VARIABLE'SPEED F.VRNACE' r ' 024 101 099 CC5A/CD5AW 024 101 0.93 FC4BNF 024 101 099 CK5A/CK5BW 024 1.01 093 FF1(B,C,D)NA 018 098 096 COILS,`,;; 55M,V042080VARIABLE:SPEED FURNACE' 024 101 1 00 CC5A/CD5AW 024 101 092 FG3AAA 024 1.00 1 00 CK5A/CK5BW 024 1 01 092 See notes on page 21 -14- DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES°F AIR 85 95 1 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht System MBtuht System MBtuht System MBtuht System MBtuht System CFM EWB Total Sens* Kw** Total Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** 1 Outdoor Secti•n With CC5A/CD5AA024 IndoorSection 72 257 126 188 248 123 209 238 119 231 227 11.5 25 216 111 284 700 67 234 159 189 226 155 209 216 151 231 207 147 25 19.7 143 282 62 21.3 191 189 205 187 209 196 182 230 187 178 25 178 173 282 57 203 203 189 196 196 209 189 189 230 182 182 25 175 17.5 282 72 26.1 132 1.92 25.2 128 213 242 125 2 35 231 121 26 220 117 2.88 800 67 239 168 192 230 165 213 220 161 2.35 210 157 26 200 153 286 62 218 203 193 209 19.9 213 200 194 234 191 188 25 182 182 286 57 211 211 1.93 204 204 1 212 1 197 1 197 1 234 1 189 1 189 1 25 1 181 1 181 1 287 72 265 137 1.96 25.6 133 217 245 130 239 234 126 26 222 122 292 900 67 242 177 1.96 233 17.4 217 223 170 239 213 166 26 202 162 290 62 221 214 197 213 209 217 204 203 238 195 195 26 187 187 291 57 21.8 218 196 1 211 1 21.1 216 203 203 238 1 195 19.5 26 187 187 290 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling, Indoor Cooling Section Size Capacity Power Section I Size I Capacity I Power CC5A/CD5AA 024 1 00 1 00 'COILS},333(BJ)AV036060 VARIABLE SPEED FURNACE 030 101 100 CC5A/CD5AA 030 103 0.90 CC5A/CD5AW 024 1 00 1 00 CE3AA 030 1 03 090 030 101 100 CK3BA 024 100 0.92 CE3AA 024 1 00 1 00 030 1 01 091 030 101 100 CK5A/CK5BA 024 100 0.92 CF5AA 024 1 00 1 00 030 1 01 091 CK36A 024 1 00 1 00 CK5A/CK5BW 1 030 1 01 091 030 1 01 1 00 'COILS 355MAV042040 VARIABLE; DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIRTEMPERATURES°F AIR 85 95 105 115 1 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht System MBtuht System MBtuht System MBtuht System MBtuht System CFM EWB Total Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** Total I Sens$ Kw** Total Sens$ Kw** 1 1 Outdoor Secti•n With CC5-A/CD5AA030 Indoor Section 72 323 158 237 310 153 2.68 298 148 304 284 143 34 270 138 386 875 67 296 198 239 285 194 2.71 273 189 307 260 183 34 246 178 386 62 270 238 241 259 23.3 273 248 228 309 23.7 222 34 22.4 215 386 57 256 256 243 248 248 2.75 239 239 309 229 229 34 220 220 3.88 72 328 164 240 316 159 272 303 155 308 289 150 34 274 144 392 1000 67 301 21 0 244 29.0 205 276 277 200 310 26.4 195 34 250 189 392 62 275 254 246 265 248 278 25.3 242 3.14 241 235 35 229 227 391 57 26.5 26 5 246 257 257 278 248 248 3 13 238 238 35 228 22.8 393 72 333 170 2.44 320 166 277 307 161 313 292 156 35 276 150 394 1125 67 306 221 248 293 21 6 2.79 28 1 21 1 315 267 205 35 25.3 200 397 62 280 267 250 26.9 261 283 257 254 3 17 245 245 35 234 234 397 57 274 274 250 264 26.4 281 255 25.5 3.17 245 245 35 234 234 398 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 030 1 00 1 00 CK3BA 030 1 00 093 036 1 02 1 00 036 1 02 091 CC5A/CD5AW 030 1 00 1 00 CK5A/CK5BW 030 1 00 093 CD5AW 036 1 02 1 00 036 1 02 091 CE3AA 030 1 00 1 00 COILS+`355MAV042o4o VARIABLE SPEED,F,URNACE 036 1 02 1 00 CC5A/CD5AA 030 1 02 094 CF5AA 036 1 02 1 00 036 1 03 093 CK313A 030 1 00 1 00 CK3BA 030 1 00 096 036 1 02 1 00 036 1 02 095 CK5A/CK5BA 030 1 00 1 00 CK5A/CK5BW 030 1 00 096 036 1 02 1 00 036 1 02 095 CK5A/CK5BN 036 095 1 00 COILS+'355MAV042060 VARIABLE SPEED FURNACE CK5A/CK5BW 030 1 00 1 00 CC5A/CD5AA 030 1 02 094 036 1 02 1 00 036 1 03 093 F(A,B)4ANF 030 1 01 099 CK3BA 030 1 00 096 036 1 02 1 01 036 1 02 095 FC4BNF 030 1 01 099 CK5A/CK5BA 036 1 02 095 036 1 02 1 01 CK5A/CK5BW 1 030 1 1 00 1096 FF1(B,C,D)NA 030 102 100 COILS+,355MAV042080VARIABLE''SPEEDFURNACE FG3AAA 036 1 01 1 00 CC5A/CD5AA 030 1 02 094 FK4BNF 001 1 02 096 036 1 03 093 002 1 02 0.96 CK3BA 030 1 00 096 003 1 03 092 036 1 02 094 004 1 04 093 CK5A/CK5BW 030 1 00 096 FK4CNF 001 1 02 096 036 1 02 094 002 1 02 096E VARIABLE'SPEED FURNACE 003 1 1 03 1 0.92 CK3BA 030 1 00 097 COILS,+333(B,J)AV036060 VARIABLE SPEED FURNACE-, 036 1 02 095 CC5A/CD5AA 036 1 03 091 CK5A/CK5BW 030 1 00 097 CE3AA 036 1 03 092 036 1 02 095 CK313A 030 100 0.94 COILS+„355MAV060100VARIABLE'SPEED,FURNACE' 036 1 02 093 CK5A/CK5BW 030 1 1 00 094 CK5A/CK5BA 030 1 00 094 036 1 02 093 036 1 02 093 CK36A 030 1 00 0.94 CK5A/CK5BN 1 036 095 0.94 036 1 02 1 093 CK5A/CK5BW 030 1 00 094 COILS+`355MAV060120 VARIABLE SPEED FURNACE, COILS+333(B,J)AV048080'VARIABLE SPEED FURNACE CK313A 030 1 00 094 CC5A/CD5AA 036 1 1.03 091 036 1 02 093 CE3AA 036 1 03 092 1 CK5A/CK5BW 036 1 02 0_93 See notes on page 21 -16- DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES°F AIR 85 95 1 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht System MBtuht System MBtuht System MBtuht System MBtuht System CFM EWB Total Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** 1 Outdoor Secti•n With CC5A/CD5AA036 IndoorSection 12 390 193 291 37.6 187 323 359 181 356 342 175 39 325 169 436 1050 67 35.8 24 5 2 89 344 239 321 328 232 353 313 226 39 297 220 4.32 62 32 7 29.4 287 314 28 8 319 300 281 351 286 274 38 27.1 265 429 57 313 31 3 2 87 303 30.3 318 292 29.2 351 280 280 38 269 269 429 72 39.7 202 2 97 38.2 196 3,29 366 190 362 348 184 40 328 17.7 440 1200 67 364 260 2 95 35.0 254 327 334 247 360 318 24 1 39 302 235 4.39 62 334 314 2 94 320 307 324 306 29.9 359 291 289 39 278 278 434 57 325 325 293 314 314 325 303 303 358 290 290 39 278 278 435 72 403 210 303 385 204 333 369 198 369 351 192 40 332 185 447 1350 67 369 274 301 353 267 3.31 338 262 366 322 255 40 303 248 442 62 33 9' 331 300 325 322 329 31.2 31 2 364 299 299 40 285 285 440 57 1 335 335 1 299 324 324 331 312 1 312 364 299 299 1 4.0 285 285 1 4.40 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 036 1 00 1 00 CE3AA 042 1 01 093 042 100 1 00 CK3BA 036 1 00 092 CC5A/CD5AW 042 1 00 1 00 042 1 00 093 CD5AW 036 1 00 1 00 CK5A/CK5BA 042 1 00 093 CE3AA 036 099 1 00 CK5A/CK5BW 1 036 1 00 1092 042 1 01 1 00 OAS,+333(B,J)AV060900 VARIABLE SPEED FURNACE, CF5AA 036 1 01 1 00 CC5A/CD5AA 042 1 01 093 CK36A 036 1 00 100 CE3AA 042 1 01 093 042 1 00 1 00 CK313A 036 1 00 092 CK5A/CK5BA 036 1.00 1.00 042 100 0.92 042 1 00 1 00 CK5A/CK5BA 042 1 00 092 CK5A/CK5BN 036 094 1.00 CK5A/CK5BW 1 036 1 00 1 092 042 097 1 00 .,,i 'COILS+333,(%J)AV060120 VARIABLE SPEEDiFURNACE CK5A/CK5BW 036 1 00 1 00 CC5A/CD5AA 042 1 01 093 F(A,B)4ANF 036 1 00 1 00 CE3AA 042 1 01 093 F(A,B)4AN(F,B) 042 1 01 1 01 CK36A 042 1 00 092 FC4BNF 036 1 00 1 00 CK5A/CK5BA 042 1 00 092 FC4BN(F,B) 042 1 01 1 01 CK5A/CK5BW 036 1 00 092 FC4BNB 054 1 03 1 00 COILS+355MAV042040"VARIABLE SPEED FURNACE FG3AAA 036 1 099 1 00 CC5A/CD5AA 036 1 01 092 FK46NF 001 1 00 098 042 1 01 092 002 1 00 098 CK313A 036 1 00 094 003 1 01 0.93 042 1 00 093 004 1 01 095 CK5A/CK5BA 042 1 00 093 FK4BNB 005 1 03 094 CK5A/CK5BW 1 036 1 1 00 1 094 006 1 03 093 COILS+355MAV042060 VARIABLE SPEED FURNACE" FK4CNB 006 1 1 03 093 CC5A/CD5AA 036 1 01 092 FK4CNF 001 1 00 098 042 1 01 092 002 1 00 098 CK36A 036 1 00 094 003 1 01 093 042 1 00 094 005 1 03 1094 CK5A/CK513A 036 1 00 094 COILS+333(BJ)AV036060`VARIABLE SPEED FURNACE CK5A/CK5BN 042 1 097 094 CC5A/CD5AA 042 101 093 "COILS+355MAV042080VARIABLE-SPEED FURNACE CE3AA 042 101 093 CC5A/CD5AA 036 1 01 092 CK38A 036 1 00 0.94 042 1 01 092 042 1 00 094 CK313A 036 1 00 093 CK5A/CK5BA 036 1 00 094 042 1.00 093 CK5A/CK5BN 1036 1094 1093 CK5A/CK5BA 042 1 00 093 COILS+333(0,4)AV048080 VARIABLE.SPEED FURNACE CK5A/CK5BW 036 1 00 093 CC5A/CD5AA 1 042 101 093 — — — See notes on page 21 —17— DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIRTEMPERATURES°F AIR 85 95 105 115 1 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht System MBtuht System MBtuht System MBtuht System MBtuht System CFM EWB Total Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** 1 Outdoor SectionAA1 • ••r Section Continued 72 39.0 193 291 376 18.7 323 359 181 356 342 175 3.9 325 169 4.36 1050 67 35.8 24 5 289 344 239 321 328 232 353 313 226 39 297 22.0 432 62 32 7 294 287 31.4 288 319 300 281 351 286 274 38 27.1 265 4.29 57 31.3 313 287 303 30.3 318 292 292 351 280 28.0 38 269 26.9 429 72 397 202 297 38.2 196 329 365 190 362 348 184 4.0 328 177 4.40 1200 67 364 260 295 350 254 3.27 334 247 360 31 8 24.1 39 302 235 4.39 62 384 314 294 320 30.7 324 306 299 359 291 289 39 278 27.8 434 57 325 325 293 314 314 325 303 303 358 290 290 39 278 278 4.35 72 40.3 210 3 03 385 204 3.33 369 198 3.69 351 192 40 332 18.5 447 1350 67 369 274 301 353 26.7 331 33.8 262 366 322 255 40 303 248 4.42 62 339 331 300 325 322 329 312 312 364 299 299 40 285 28.5 440 57 335 1 33.5 299 324 32.4 331 312 31 2 364 299 299 40 28.5 285 440 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity I Power Section Size Capacity Power COILS,+'355,MAV06,OO80�VARIABLE SPEED FURNACE;' CK36A 036 1 00 092 CK3BA 036 1.00 0.94 042 1 00 092 042 1 00 0.94 CK5A/CK5BA 042 1 00 092 CK5A/CK5BA 042 1 00 094 CK5A/CK5BW 036 1 1 00 092 CK5A/CK5BW 036 1 00 094 ;;COILS"+'355MAV060120.VARIABLE-SFIEED`,FURNACE. COILS+355 MAV060106MARIABL'E'SPEED FURNACE CK5A/CK5BA 042 1.00 092 CC5A/CD5AA 036 1 01 092 CK5A/CK5BW 036 1 00 092 042 1.01 093 - - - See notes on page 21. -18- DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES°F AIR 85 95 105 115 1 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht System MBtuht System MBtuht System MBtuht System MBtuht System CFM EWB Total I Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** Total I Sens$ I Kw** Total Sens$ Kw** 1 Outdoor Secti•n With CC5A/CDSBAA042 IndoorSection 72 45.8 225 347 441 21.8 383 423 212 422 405 205 46 387 198 513 1225 67 41 8 283 3.44 402 276 378 386 270 417 369 263 46 352 256 507 62 38.0 339 340 366 332 374 351 325 413 336 317 45 32 1 309 502 57 362 362 338 351 351 373 339 339 412 327 327 45 315 31 5 501 72 466 23.5 355 449 228 391 430 221 4.29 41.2 21 5 47 393 208 521 1400 67 426 300 352 410 29.3 3.87 393 287 425 375 279 46 358 272 515 62 38.8 362 348 374 354 383 358 345 420 343 33'6 46 328 326 510 57 376 376 346 36.4 364 381 352 352 420 33.9 339 46 326 326 5.11 72 473 244 362 455 23.7 3.98 436 231 437 416 224 48 396 217 528 1575 67 433 316 359 41 5 310 394 398 303 432 38.0 295 47 362 288 522 62 395 382 3.56 380 372 390 365 362 428 350 350 47 336 336 519 57 389 389 3.55 376 376 1 3.89 363 363 428 349 34.9 1 47 336 336 519 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 042 1.00 100 CK5A/CK5BA 042 100 0.93 CC5A/CD5AC 048 099 1.00 CK5A/CK5BW 048 1 00 093 CC5A/CD5AW 042 1 00 1 00 COILS+333(B;J)AV060120 VARIABLE SPEED+FURNACE 048 1 00 1 00 CD5AA 048 1 00 092 CD5AA 048 1 00 1 00 CE3AA 048 1 00 092 CE3AA 042 1 00 1 00 CK313A 042 1 00 093 048 1.01 1 00 048 1 00 093 CF5AA 048 101 100 CK5A/CK56A 042 100 0.93 CK3BA 042 1 00 1 00 CK5A/CK5BW 048 1 00 093 048 100 1.00 COILS+:355MAV042060,VAkIABLE.SP.EEDFURNACE; , CK5A/CK5BA 042 1 1 00 1 00 CK36A 042 099 096 048 1.00 1 00 048 1.00 095 CK5A/CK5BN 042 098 1 00 CK5A/CK5BN 042 098 096 048 098 1.00 048 0.98 096 CK5A/CK5BW 048 1 00 1 00 COILS+355MAV,042080 VARIABLE SPEED,FURNACE, F(A,B)4AN(F,B) 042 1.00 101 CC5A/CD5AA 042 100 0.93 048 1.01 1 02 CD5AA 048 1 00 092 FC4BN(F,B) 042 1.00 1 01 CK313A 042 099 095 048 1 01 1 02 048 1 00 095 FC4BNF 038 1 02 1 02 CK5A/CK5BA 042 099 095 FC4BNB 054 1.05 1 00 1 048 1 1 00 1095 FG3AAA 048 1 00 1 00 COILS+,355MAV060080 VARIABLE SPEED FURNACE, FK4BNB 005 1 02 096 CK3BA 042 099 096 006 1.05 094 048 1.00 095 FK4BNF 003 1 1 01 095 CK5A/CK5BA 042 099 096 FK4CNB 006 1.05 094 048 1 00 095 FK4CNF 003 1 01 095 »COILS_+355MAV060100•VARIABLE SPEED FURNACE,, 005 1.02 096 CC5A/CD5AA 042 1 00 093 sCOILS,+'333(B,J),4V1148080VARIABLE"SPEED.FURNACE`" CD5AA 048 100 0.92 CD5AA 048 1 00 092 CK313A 042 099 094 CE3AA 048 1 00 092 048 1 00 093 CK36A 042 1 00 095 CK5A/CK5BA 042 099 094 048 1 00 0.94 CK5A/CK6BW 1 048 1 1.00 1 093 CK5A/CK5BA 042 1 00 095 COILS+'355MAV060120 VARIABLE SPEED FURNACE.,, _ 048 1 00 1 094 CK3BA 042 099 094 "COILS:+333(B;J)AV060100 VARIABLE SPEED FURNACE' 048 1 00 0.93 CD5AA 048 1 00 092 CK5A/CK5BA 042 0.99 094 CE3AA 048 1 00 092 CK5A/CK5BW 048 1 00 093 CK3BA 042 1 00 093 - - - 048 1 00 093 See notes on page 21 -19- DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIRTEMPERATURES°F AIR 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht System MBtuht System MBtuht System MBtuht System MBtuht System CFM EWB Total Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** Total Sens# Kw** 14 • •• 'SectionAA1.1 Indoor Section 72 53 5 258 409 515 25 1 '458 494 243 513 471 234 569 447 225 631 1400 67 489 32 2 404 471 314 453 450 30.6 505 43.0 297 562 408 288 6.23 62 446 38.5 400 429 377 448 410 367 499 390 358 555 370 34.8 614 57 41 8 418 397 404 404 444 390 390 496 375 375 552 359 359 612 72 546 269 4.17 525 261 467 503 253 521 478 244 578 454 235 641 1600 67 500 34 1 412 480 333 462 459 324 514 437 31 5 571 414 306 632 62 456 410 408 437 401 456 418 39.1 508 398 381 564 378 369 623 57 435 435 406 42.0 1 420 455 1 405 405 1 506 1 389 1 389 1 5.63 1 373 1 373 623 72 555 279 425 532 271 475 510 263 530 485 254 587 459 245 650 1800 67 508 35.8 421 48.7 350 469 46.5 341 522 443 332 5.79 42 0 323 6.41 62 463 433 416 445 423 464 425 412 517 405 399 573 38.4 384 633 57 449 449 415 43.4 434 463 418 418 5.16 401 401 5 73 38 3 383 632 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AA 060 1 00 1 00 CK5A/CK5BA 060 098 094 CC5A/CD5AC 048 098 099 CK5A/CK5BW 048 098 094 CC5A/CD5AW 048 099 1 00 CK5A/CK5BX 060 1 01 093 060 1 01 1 00 ,COILS,+333(13;J)AV660120VARIABLE"SPEEDFURNACE` " CD5AA 048 099 1 00 CC5A/CD5AA 060 098 094 CE3AA 048 099 1 00 CC5A/CD5AW 048 098 094 060 1 00 1 00 060 1.01 094 CF5AA 048 0.99 099 CK36A 048 0.98 094 CK36A 048 099 1 00 CK5A/CK5BA 060 098 094 060 1 00 1 00 CK5A/CK5BW 048 098 095 CK5A/CK5BA 048 099 1 00 CK5A/CK5BX 060 1 01 1 094 060 1 00 1 00 C6ILS+`355MAV042080VARIABLE,SPEED'FURNACE CK5A/CK5BN 048 096 098 CD5AA 048 098 097 060 1 00 1 00 CK313A 048 0 98 097 CK5A/CK56T 048 099 1 00 CK5A/CK5BA 048 098 097 060 1 00 1 00 CCOI, LS+355MAV,060080,VARIABLE SPEED-FURNACE;; ' CK5A/CK5BW 048 099 1 00 CC5A/CD5AA 060 098 098 CK5A/CK5BX 060 1 01 1 00 CC5A/CD5AW 060 1 00 098 F(A,B)4AN(F,B,C) 048 099 1 02 CD5AA 048 098 0.98 060 1 00 1 03 CK313A 048 098 098 FC4BN(F,B) 048 099 1 02 CK5A/CK56A 048 098 098 060 1 00 1 03 060 098 098 FC4BNB 054 1 01 1 02 CK5A/CK5BX 060 1 00 098 070 1 00 1 02 COILS,+355MAV060100 VARIABLE SPEED;FURNACE: FG3AAA 048 099 1 00 CC5A/CD5AC 048 096 0.97 060 1 00 1 00 CC5A/CD5AW 060 1 00 096 FK4CN6 006 1 01 094 CD5AA 048 098 096 FK4CNF 1 005 099 095 CK36A 048 098 096 COILS+'333(B,J)AV048080 VARIABLE SPEED FURNACE',, , A. 060 098 096 CC5A/CD5AC 048 096 097 CK5A/CK5BA 048 098096 CD5AA 048 098 097 CK5A/CK5BX 060 1.00 096 CK3BA 048 098 0.97 .,"COIL'"S'+"355MAV060120 VARIABLE SPEED,FURNACE CK5A/CK5BA 048 098 097 CC5A/CD5AA 060 098 096 99ILS+°333(B,J)AV060100,VARIABLE SPEED'FURNACE,`, CC5A/CD5AW 048 098 096 CC5A/CD5AA 060 098 093 060 1 00 0.95 CC5A/CD5AW 048 098 094 CK5A/CK5BA 060 098 0.96 060 101 093 CK5A/CK5BW 048 098 096 CK313A 060 0.98 094 CK5A/CK5BX 060 1 00 096 See notes on page 21 —20— DETAILED COOLING CAPACITIES* Continued EVAPORATOR CONDENSER ENTERING AIR TEMPERATURES*F AIR 85 95 105 115 125 Capacity Total Capacity Total Capacity Total Capacity Total Capacity Total MBtuht System MBtuht System MBtuht System MBtuht System MBtuht System CFM EWB Total Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** Total Sens$ Kw** 1 .1 Outdoor Section1.1 Indoor Section 72 63.6 31 1 498 612 303 551 587 293 6 08 56 1 284 6.71 53,5 274 7 41 1750 67 58 2 392 490 560 383 542 537 374 5.99 51.3 364 662 489 354 7.31 62 53.1 471 483 51 0 461 5.34 489 451 590 468 440 653 44.6 428 721 57 504 504 480 488 488 531 472 472 588 45.5 455 650 437 437 719 72 648 325 509 623 316 562 597 306 620 57.0 297 684 542 286 750 2000 67 593 415 501 570 406 553 546 396 611 521 386 673 496 376 743 62 542 502 494 520 491 546 498 479 602 476 466 665 45.4 451 734 57 1 523 1 523 1 492 1 506 1 506 1 543 1 488 1 488 600 470 1 470 1 662 1 452 1 452 7.32 72 657 337 520 63 1 328 573 604 31 8 631 57 7 309 694 546 298 7.60 2250 67 602 437 512 578 428 564 553 41 8 622 528 408 684 502 398 7.54 62 550 529 505 528 516 557 50.6 502 614 485 485 676 464 464 745 57 540 540 5.03 52.2 522 555 50_3 50 3 1 612 1 484 484 675 464 464 745 Multipliers for Determining the Performance With Other Indoor Sections Indoor Cooling Indoor Cooling Section Size Capacity Power Section Size Capacity Power CC5A/CD5AW 060 100 100 FK4BNB 006 102 100 CC5A/CD5AA 060 0.96 097 FK4CNB 006 102 1 00 CE3AA 060 100 100 ,COILS+`333(B;J)AV060100VARIABLEtSPEEb'FURNACE' CK3BA 060 096 1 00 CC5A/CD5AW 1 060 1 00 096 CK5A/CK5BA 060 096 098 CK36A 060 097 095 CK5A/CK5BN 060 096 098 CK5A/CK5BA 060 097 096 CK5A/CK5BX 060 1.00 1 00 CK5A/CK5BX 060 099 095 F(A,B)4AN(F,B) 060 1.00 1 04 :COILS.#;333(B;J)AV060120VARIAIJLE�SPEED,FURNACE i:;,,;. FB4ANB 070 102 102 CK36A 060 0,97 0.96 FC4BN(F,B) 060 1 00 1.04 CK5A/CK5BA 060 097 097 FC4BNI3 070 1 02 1 02 CK5A/CK5BX 060 099 '096 FG3AAA 060 100 100 — — — * Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94 If additional tubing length and/or indoor unit is located above outdoor unit,a slight variation in capacity may occur t Total and sensible capacities are net capacities Blower motor heat has been subtracted t Sensible capacities shown are based on 80°F(27°C)entering air at the indoor coil For sensible capacities at other than 80°F(27C),deduct 835 Btuh(245 kw)per 1000 CFM(480 US)of indoor coil air for each degree below 80°F(27°C),or add 835 Btuh(245 kw)per 1000 CFM(480 US)of indoor coil air per degree above 80°F(27°C) When the required data falls between the published data,interpolation may be performed ** Unit kw is total of indoor and outdoor unit kilowatts —21— CONDENSER ONLY RATINGS* SST CONDENSER ENTERING AIR TEMPERATURES°F °F 55 65 75 1 85 1 95 105 115 597CO18-F TCG 165 158 15.0 142 134 126 117 30 SDT 750 850 950 1050 1150 1250 1350 KW 0 781 0.900 1 03 1.18 135 152 171 TCG 182 174 166 158 149 140 131 35 SDT 751 851 951 1050 1150 1250 135.0 KW 0 781 0 901 1 03 1 18 1.35 153 172 TCG 200 192 18.3 174 165 15.5 146 40 SDT 75.3 853 95.3 1050 1150 1250 1350 KW 0 784 0 904 1 04 1 19 1 35 1 53 1 73 TCG 219 210 201 191 18.1 171 161 45 SDT 76.1 860 96.0 1060 1160 1260 1360 KW 0.794 0.913 105 120 136 154 174 TCG 23.9 229 21.9 209 199 188 177 50 SDT 770 86.9 969 1070 1170 1270 1370 KW 0 806 0 924 1 06 121 1 38 1 56 1 76 TCG 260 250 239 228, 21 7 206 194 55 SDT 78$ 881 98.0 1080 118.0 1280 138.0 KW 0.822 0 941 1 07 1 23 1 39 158 1 78 597CO24-F TCG 215 206 195 184 173 162 152 30 SDT 75.0 85.0 950 1050 1150 1250 135.0 KW 1 19 134 150 168 1.87 208 233 TCG 236 22.8 217 20.6 194 182 170 35 SDT 750 850 950 1050 1150 1250 1350 KW 1 17 1.32 149 1.67 186 208 2 32 TCG 259 250 240 22.9 216, 203 19.0 40 SDT 750 850 95.0 1050 115.0 1250 1350 KW 1 15 1.30 1 47 1 65 1 85 207 231 TCG 282 274 264 25.3 240 22.6 212 45 SDT 750 850 95.0 1050 1150- 1250 1350 KW 1 12 128 1 45 1 63 1 84 206 230 TCG 306 299 289 27.8 265 25.1 236 50 SDT 750 851 951 1050 1150 1250 1350 KW 1.10 1 25 142 1.61 182 204 229 TCG 332 324 31 5 304 291 27 6 26 1 55 SDT 754 853 95.3 1050 115.0 125 0 135 0 KW 1 07 122 1 39 1 59 1 80 2 03 2 27 597CO30-F TCG 275 26 3 25 0 237 224 209 19.4 30 SDT 750 85 0 950 105.0 1150 1250 1350 KW 141 1 65 191 2.20 252 286 322 TCG 30.3 290 277 26.3 248 23.3 21 8 35 SDT 75.1 851 951 1050 1150 1250 1350 KW 1 36 1.60 1 86 2 15 248 282 3.20 TCG 333 31 9 30.5 290 27.5 259 242 40 SDT 75.4 853 953 1050 1150 1250 1350 KW 1 32 1 55 181 2 11 243 279 3.17 TCG 364 350 33 4 31 9 302 286 268 45 SDT 761 860 960 1060 116 0' 1260 1360 KW 1 28 1 51 1 78 207 240 275 314 TCG 397 382 365 349 33 1 31.4 295 50 SDT 770 869 968 1070 1170 1270 1370 KW 125 148 174 203 2.36 272 312 TCG 432 41 5-7 39.8 38.0 362 343 323 55 SDT 784 881 980 1080 1180 1280 1380 KW 1.22 145 1 71 200 233 269 309 597CO36-F TCG 33.4 31 9 303 287 271 254 236 30 SDT 750 85.0 950 1050 1150 125.0 1350 KW 1 76 1 99 224 252 283 316 352 TCG 36.8 352 335 31.8 301 283 264 35 SDT 754 852 952 1050 115,0 1250 1350 KW 1 76 1 98 223 251 282 316 3.52 TCG 403 386 369 351 332 31.3 293 40 SDT 76.2 860 959 1060 1160 1260 136.0 KW 1 76 1 98 223 251 282 316 353 TCG 44.0 423 404 385 365 34.5 323 45 SDT 774 871 969 107.0 1170 1270 1370 KW 1-77 1 99 224 252 283 318 3.55 TCG 48.0 461 44.1 420 39.9 37.8 355 50 SDT 78.9 88.5 983 1080 1180 1280 1380 KW 1 78 200 226 254 2.85 319 357 TCG 52 1 50.1 48 0 45 8 436 41 3 389 55 SDT 80.5 901 997 1090 1190 129 0 1390 KW 1 80 2.02 2 28 2 56 2.87 3 22 360 See notes on page 23. -22- CONDENSER ONLY RATINGS* Continued SST CONDENSER ENTERING AIR TEMPERATURES°F °F 55 65 1 75 85 1 95 1 105 1 115 597CO42-F TCG 386 368 35.0 332 31 4 296 27 9 30 SDT 750 849 950 1050 1150 1250 1350 KW 216 242 2.71 303 3 39 3 80 4.25 TCG 427 408 38.8' 369 349 330 31.1 35 SDT 750 850 950 1050 115.0 1250 1350 KW 215 240 2.70 302 3.38 379 424 TCG 470 450 43.0 408 387 36.6 345 40 SDT 752 85.0 95.0 1050 1150 125.0 1350 KW 214 239 268 300 337 377 422 TCG 514 493 47.2 450 427 40.5 382 45 SDT 767 862 95.8 1050 1150 1250 135.0 KW 2.15 2.40 268 300 3.36 375 420 TCG 559 537 51.5 49.2 468 444 42.0 50 SDT 784 878 973 1070 1160 1260 1360 KW 218 243 271 303 3.38 3.77 421, TCG 607 584 56.0 536 51 1 485 460 55 SDT 803 896 99.1 1090 1180 1280 1370 KW 221 2.46 275 307 342 381 425 597CO48-G, TCG 46 4 44 2 420 397 374 35.0 32 5 30 SDT 754 85 1 950 1050 1150 1250 1350 KW 229 264 3.03 348 396 448 503 TCG 509 486 463 43.9 415 390 364 35 SDT 77.0 865 961 1060 1150 1250 1350 KW 230 265 304 347 395 4.46 502 TCG 556 532 508 48.2 457 430 403 40 SDT 788 883 97.8 1070 1170 1260 136.0 KW 233 2.68 307 351 398 450 505 TCG 606 580 554 527 500 47.2 443 45 SDT 808 902 997 1090 1190 1280 1380 KW 235 271 311 355 403 455 512 TCG 659 631 604 57.5 546 51 6 48.5 50 SDT 829 923 1020 111.0 121 0 1300 1390 KW 239 275 315 360 4.09 462 519 TCG 71.4 685 656 625 594 562 530 55 SDT 852 945 1040 113.0 1230 1320 141.0 KW 242 2.79 3.20 3 65 414 468 52 597CO60-F TCG 550 52.6 502 47.6 450 42.4 399 30 SDT 76 1 858 956 105.0 1150 1250 1350 KW 288 325 366 413 4.61 5.08 556 TCG 60.2 577 55 1 523 49.6 46,9 441 35 SDT 77.8 874 971 1070 1160 1260 1360 KW 2.92 329 370 417 465 512 559 TCG 656 630 603 573 54.4 51.4 485 40 SDT 796 89.2 988 1080 1180 128.0 1370 KW 296 3.34 375 423 471 519 567 TCG 71 3 687 658 626 595 564 532 45 SDT 81 5 912 101 0 110.0 1200 129.0 1390 KW 301 339 382 430 478 527 575 TCG 773 745 71 5 682 648 61 5 582 50 SDT 836 93.2 103.0 112.0 1220 131 0 141 0 KW 3.05 345 3.88 437 486 536 5.85 TCG 836 807 775 740 705 67.0 635 55 SDT 858 954 1050 1140 1240 1330 1430 KW 311 351 3,95 445 495 545 596 *ARI listing applies only to systems shown in Ratings and Performance table KW -Total Power(Kw) SDT-Saturated Temperature Leaving Compressor(°F) SST-Saturated Temperature Entering Compressor(°F) TCG-Gross Cooling Capacity(1000 Btuh). -23- SYSTEM DESIGN SUMMARY 1 Intended for outdoor installation with free air inlet and outlet Outdoor fan external static pressure available is less than 0 01-m wc. 2 Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F(12.8°C). 3. Maximum outdoor operating air temperature is 125°F(51.7°C) 4. For reliable operation,unit should be level in all horizontal planes. 5 Maximum elevation of indoor coil above or below base of outdoor unit is.Indoor coil above=50 ft,indoor coil below=150 ft 6 For interconnecting refrigerant tube lengths between 50 and 175 ft,consult the_ Residential Split System Long-Line Application Guideline available from equipment distributor. 7 If any refrigerant tubing is buried,provide a minimum 6-in vertical rise to the valve connections at the unit Refrigerant tubing lengths up to 36 in. may be buried without further consideration For buried lines longer than 3 ft,consult your local distributor. 8. Use only copper wire for electric connection at unit.Aluminum and clad aluminum are not acceptable for the type of connector provided. 9. Mix-matches of indoor coil capacity more than 1 size larger than outdoor unit capacity may result in inadequate indoor comfort. 10 Do not apply capillary tube indoor coils to these units -24- MATCHED SYSTEM AIR CONDITIONER ® I I O � 0 I o 00o VENTILATOR PLUSTM ZONE PERFECT PLUSTM HUMIDIFIER EQUIPMENT CONTROLLER ' FURNACE COIL O ® I FURNACE 0 AIR CLEANER o ' A98599 -25- GUIDE SPECIFICATIONS Air-Cooled, Split-System Air Conditioner S97C 1-1/2 to STons Nominal GENERAL Condenser fan motors will be totally enclosed, 1-phase type System Description with class B insulation and permanently lubricated bearings. Outdoor-mounted, air-cooled, split-system air conditioner unit Shafts will be corrosion resistant. suitable for ground or rooftop installation Unit consists of a her- Fan blades will be statically and dynamically balanced. metic compressor, an air-cooled coil, propeller-type condenser Condenser fan openings will be equipped with steel wire safety fan, and a control box. Unit will discharge supply air upward as guards shown on contract drawings Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit. Compressor Quality Assurance Compressor will be hermetically sealed. Unit will be rated in accordance with the latest edition of ARI Compressor will be mounted on rubber vibration isolators. Standard 210 Condenser Coil Unit will be certified for capacity, efficiency, and listed in the lat- Condenser coil will be air cooled. est ARI directory Coil will be constructed of aluminum fins mechanically bonded Unit construction will comply with latest edition of ANSI/ to copper tubes which are then cleaned, dehydrated, and ASHRAE and with NEC. sealed Unit will be constructed in accordance with UL standards and Refrigeration Components will carry the UL label of approval.Unit will have c-UL approval Refrigeration circuit components will include liquid line shutoff Unit cabinet will be capable of withstanding Federal Test valve with sweat connections, suction line shutoff valves with Method Standard No 141 (Method 6061)500-hr salt spray test sweat connections, system charge of R22 refrigerant,and com- Air-cooled condenser coils will be leak tested at 150 psig and Pressor oil pressure tested at 300 psig. Operating Characteristics Unit constructed in ISO 9001 approved facility The capacity of the unit will meet or exceed Btuh at a Delivery,Storage,and Handling suction temperature of °F The power consumption at full Unit will be shipped as single package only and is stored and load will not exceed kw handled per unit manufacturer's recommendations Combination of the unit and the evaporator or fan coil unit will Warranty(for inclusion by specifying engineer) have a total net cooling capacity of Btuh or greater at conditions of CFM entering air temperature at the evapo- U S.and Canada only. rator at °F wet bulb and of dry bulb, and air enter- PRODUCTS ing the unit at of Equipment The system will have an SEER of Btuh/watt or greater at Factory-assembled, single-piece, air-cooled air conditioner unit DOE conditions Contained within the unit enclosure will be all factory wiring,pip- Electrical Requirements ing, controls, compressor, refrigerant charge(R22), and special Nominal unit electrical characteristics will be v, single features required prior to field start-up. phase, 60 hertz The unit will be capable of satisfactory opera- Unit Cabinet tion within voltage limits of v to v Unit cabinet will be constructed of galvanized steel, bonderized, Unit electrical power will be single point connection and coated with a powder coat paint Control circuit will be 24v Fans Special Features Condenser fan will be direct-drive propeller type, discharging air Refer to section of this literature identifying accessories and upward. descriptions for specific features and available enhancements. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE I=. WITH INSTALLATION INSTRUCTIONS Heating&Cooling Systems Cancels PDS 5970 18 7 c ©1999 Bryant Healing&Cooling Systems,-7310 W Moms St,Indpls,IN 46231 —28— PRINTED IN U S A Catalog No 5259-704 11-99