HomeMy WebLinkAbout1000-87.-5-26 & 23.9 OFFICE LOCATION: hO�*OF SO(/j�olo MAILING ADDRESS:
Town Hall Annex P.O. Box 1179
54375 State Route 25 Southold, NY 11971
(cor. Main Rd. &Youngs Ave.) u0 �c
S ® �O� Telephone: 631 765-1938
Southold, NY 11971
Fax: 631 765-3136
COUNTY
LOCAL WATERFRONT REVITALIZATION PROGRAM
TOWN OF SOUTHOLD
MEMORANDUM
To: Michael Domino, President
Town of Southold Board of Trustees
From: Mark Terry, AICP
LWRP Coordinator
Date: October 10, 2019
Re: LWRP Coastal Consistency Review for COVE CONDOMINIUMS OWNERS ASSOCIATION
SCTM# 1000-87-5-26 & 23.9 B
Michael Kimack on behalf of COVE CONDOMINIUM OWNERS ASSOCIATION requests an
Amendment to Wetland Permit#9148 to allow for the first spoil dredging be used as backfill
landward of new low sill bulkhead; along the north bulkhead at boat dock: in lieu of removing
approximately 145' of existing wood bulkhead, to remove approximately 116' of existing north wood
bulkhead (25' and 91' sections); construct approximately 116' of new vinyl bulkhead with addition of
one 12' return at northern end of 25' section of new bulkhead (±128' total); and raised 12" higher
than existing bulkhead; backfill with clean fill and restore disturbed area; remove approximately 180'
of existing south wood bulkhead at boat ramp; construct approximately 180' of new vinyl bulkhead
with two returns; 12' on the north end and 8' on the south end for a total new length of
approximately 200' and raised 12" higher than existing; backfill with clean fill and restore disturbed
area; construction of proposed new bulkheading to consist of 9"x12' pilings at 8' o/c at approx. 8'
below grade, two (2) 6"x6" stringers spaced accordingly, shore guard 225 at 10' in length at
approx.. 6' below grade, a wood cap with 3"x6" top clamp, W x 10' tie rods with horizontal lag log,
with 8" backer pilings at 8' o/c set approx. 10' back from main pilings; construct approximately 180'
of new proposed partial low sill bulkhead; backfill with clean sand just below lower vinyl sheathing;
maintain approx. 2 to 1 slope from top of sloughed bank and then flat to bulkhead; install two (2)
layers of burlap, secure with 8" galvanized pins; plant Spartina alterniflora @ one (1) ft. o/c
throughout (approx. 2,800sq.ft.); for the restoration landward of new bulkheads: prior to clearing
vegetation, remove and preserve to the extend feasible, wetland plants that can be removed,
preserved and planted; clear and excavate landward approx. 10' from new bulkheads to place dead
men and tie rods approx. every 8', backfill with excavated material and clean fill as needed,
proposed machinery to be utilized would be small crawler backhoe with bucket; restore wetland
areas disturbed as follows: Wetland limits of disturbance area approx. 1,025sq.ft. subsequent to
backfill, replant preserved wetland plants prior to new plantings, plant approx. 70 three-gallon
Baccharis plants at 4' o/c±, intersperse plants with approx. 800 Spartina Patens at approx. 1' o/c;
wetland limits of disturbance area approx. 1,100sq.ft. subsequent to backfill, replant preserved
wetland plants prior to new plantings, plant approx. 75 three-gallon Baccharis plants at 4' o/c±,
intersperse plants with approx. 900 Spartina Patens at approx. 1' o/c; and any disturbance to the
I
intertidal march areas will be replanted with alterniflora. Located: Meadow Court & 8552 Main
Bayview Road, Southold SCTM# 1000-87-5-26 & 1,000-87-5-23.9
The proposed action has been reviewed to Chapter 268; Waterfront Consistency Review of the
Town of Southold Town Code and the Local Waterfront Revitalization Program (LWRP) Policy
Standards ,Based upon the information provided on the LWRP Consistency Assessment Form
submitted to this department, as well as the records available to me, it is my recommendation that
the proposed action is CONSISTENT with the LWRP policies and therefore CONSISTENT with the
LWRP provided the following is considered meet Policy 6.
1. The action will disturb high value low and high marsh. Establish survival rates for planted
vegetation, require re-planting of areas that do not meet survival rate.
Pursuant to Chapter 268, the Board of Trustees shall consider this recommendation in preparing its
written determination regarding the consistency of the proposed action.
Cc: Damon Hagan, Assistant Town Attorney
EIVED
Town of Southold C
t�
LWRP CONSISTENCY ASSESSMENT FORM OCT 0 4 2019
Southold Town
A. INSTRUCTIONS Planning Board
1. All applicants for permits* including Town of Southold agencies, shall complete this CCAF for
proposed actions that are subject to the Town of Southold Waterfront Consistency Review Law. This
assessment is intended to supplement other information used by a Town of Southold agency in
making a determination of consistency. *Except minor exempt actions including Building Permits.
and other ministerial permits not located within the Coastal Erosion Hazard Area.
2. Before answering the questions in Section C, the preparer of this form should review the exempt
minor action list, policies and explanations of each policy contained in the Town of Southold Local
Waterfront Revitalization Program. . A proposed action will be evaluated as to its significant
beneficial and adverse effects upon the coastal area(which includes all of Southold To3DJ.
3. If any question in Section C on this form is answered "yes" or "no", then the proposed action will
affect the achievement of the LWRP policy standards and conditions contained in the consistency
review law. Thus, each answer must be explained in detail, listing both supporting and non-
supporting facts. If an action cannot be certified as consistent with the LWRP policy standards and
conditions,it shall not be undertaken.
A copy of the LWRP is available in the following places: online at the Town of Southold's
website (southoldtown.northfork.net), the Board of Trustees Office, the Planning Department, all
local libraries and the Town Clerk's office.
B. DESCRIPTION OF SITE AND PROPOSED ACTION
SCTM# �- �� - z 6 Z� I
PROJECT NAME CO V4 CVWPVfr/N1uh OGUi 1A&r of-Ma C
The Application has been submitted to (check appropriate response):
Town Board ❑ Planning Board❑ Building Dept. ❑ Board of Trustees
1. Category of Town of Southold agency action(check appropriate response):
(a) Action undertaken directly by Town agency(e.g. capital ❑
construction,planning activity,agency regulation,.land transaction) ❑
(b) Financial assistance(e.g. grant, loan, subsidy)
(c) Permit, approval, license, certification:
Nature and extent of action:
Pi5L2hfr ova. 9248
COVE CONDOMINIUM OWNERS ASSOCIATION
Amendments to Trustee Permit No. 9148"
AUTHORIZATION
TEN YEAR MAINTENANCE PERMIT FOR DREDGING
Wetland Permit for a ten(10)Year Maintenance Permit to maintenance dredge to three(3)feet below mean water
approximately 82 cubic yards from channel at entrance to association docking area,and as needed within the
docking area itself;dredge as necessary in the same areas to maintain width,depth and full accessibility of
entrance channel and docking area on a maximum of four(4)additional occasions during the next ten(10)years;
spoil will removed to an approved upland location for deposition. First spoil dredging maybe used as backfill
landward-of new low sill bulkhead.In accordance with the dredge plan prepared by Michael A. Kimack,received
on January 24,2018,and stamped approved on january24,2018.
AS BUILT LANDING,FIXED DOCK-and FLOATING DOCK
For the existing 31.5 sq.ft.platform leading to existing 80.8 sq.ft.fixed dock with two(2)8"diameter pilings and
two(2)8"square pilings;existing 215.5 sq.ft.walkway;and 1,758.25 sq.ft.of an existing floating dock facility
with(1'5)8"diameter pilings securing the floating docks;with the condition of the installation of a silt boom'"
prior to construction that will retain all suspended sediments within the immediate project area;and that the
decking be replaced with thru-flow decking at time of construction if possible;and if not,at time of construction,
then when repairs are made;and as depicted on the site plan prepared by Michael A.Kimack,dated October 26,
2017,and stamped approved on January 17,2018.
REPACEMENT AND EXTENSION OF EXISTING WOOD BULKHEADS
A. North Bulkhead at Boat Dock -
Remove approximately 116 feet of existing wood bulkhead.(25 ft.and 91 ft.)
Construct approx.116 feet of new Vinyl bulkhead with addition of one 12 foot return at northern end of 25 foot
section of new bulkhead(128 ft.total+/-).Set one(1)ft.higher than existing.Backfill with clean fill and restore
as proposed below.
B. South Bulkhead at Boat Ramp
Remove approximately 180 feet of existing wood bulkhead.
Construct approx.180 ft.of new Vinyl bulkhead with two returns,12 feet on the north end and 8 feet on the south
end for a total new length of approximately 200 feet,set one(1)ft.higher than existing.Back fill with clean fill and
restore as proposed below.
Construction
The new proposed bulkhead system will be constructed,utilizing 9"x12 ft.pilings at 8 ft.O/C at approx.8 ft.below
,grade,two(2)6"x6"stringers spaced accordingly,Shore guard 2251at 10 ft.in length at approx.6 ft.below grade,
a wood cap with 3"x 6"top clamp,3/4"x 10 ft.tie rods with horizontal laglog,with 8"backer pilings at 8 ft.
O.C."set approx.10 ft.back from main pilings.(See Cross Section on Site Plan))
C. PROPOSED PARTIAL LOW SILL BULKEAD W/FILL&PLANTING RESTORATION
Construct approx..180 ft.of new proposed Partial Low Sill bulkhead,(See Cross Section on Site Plan):Backfill
w/clean sand just below lower Vinyl sheathing.Maintain approx.2 tot slope from top of sloughed bank and then
flat to bulkhead.Install 2 layers of burlap,secure w/8"galy.pins, plant Spartina alterniflora @ one(1)ft.O.C.
throughout.(approx..2800 SF)
Restoration Landward of New Bulkheads
See Site Plan for Limit of disturbance Areas
Prior to clearing vegetation,remove and preserve to the extent feasible,wetland plants that can be removed,
preserved and replanted.Clear and excavate landward approx.10ft.from new bulkheads to place dead men and
tie rods approx..every 8 feet.backfill with excavated material and clean fill as needed.Proposed machinery to be
utilized would be small crawler backhoe with bucket.Restore wetland areas disturbed as follows:
A. Wetland limits of disturbance area approx..1025 SF.Subsequent to backfill,replant preserved wetland
plants prior to new plantings.Plant approx.70 three(3)gallon Baccharis plants at four(4)feet O.C.+l-,
Intersperse plants with approx..800 Spartina Patens at approx..one(1)foot O.C.
B. Wetland limits of disturbance area approx..1100 SF.Subsequent to backfill replant preserved wetland
plants prior to new plantings.Plant approx..75 three(3)gallon baccharis plants at four(4)feet O.C.
Intersperse plants with approx..900 Spartina Patens at approx..(1)foot O.C.
Note:Any disturbance to the intertidal marsh areas in sections A and B will be replanted with alterniflora
In accordance with the site plan prepared by Michael A.Kimack,dated June 19,2019 received on
and stamped approved on
i
Location of action: /AAA/ / rQVr
Site acreage:
Present land use: C' 6 VHS'
Present zoning classification: — C
IF
2. If an application for the proposed action has been filed with the Town of Southold agency, the following
information shall be provided:
(a) Name of applicant:
(b) Mailing address: C U VjOg� GO/lo jO/'f/CLIVI MA"f -45MJC
(c) Telephone number: Area Code( ) C',nLC (��/1��!' �� �j���— 6P/o
7
(d) Application number,if any: /
Will the action be directly undertaken,require funding, or approval by a state or federal agency?
Yes ❑ No❑ If yes,which state or federal agency?
C. Evaluate the project to the following policies by analyzing how the project will further support or
not support the policies. Provide all proposed Best Management Practices that will further each policy.
Incomplete answers will require that the form be returned for completion.
DEVELOPED COAST POLICY
Policy 1. Foster a pattern of development in the Town of Southold that enhances community character,
preserves open space, makes efficient use of infrastructure, makes beneficial use of a coastal location,and
minimizes adverse effects of development. See LWRP Section III—Policies; Page 2 for evaluation
criteria.
❑Yes ❑ No F—] Not Applicable
po u c Y / Alar 4)°®1. 7''b )WPS'' PM nT�rl'
Attach additional sheets if necessary
Policy 2. Protect and preserve historic and archaeological resources of the Town of Southold. See
LWRP Section III—Policies Pages 3 through 6 for evaluation criteria
❑ Yes ❑ No Not Applicable
d°duCY z Nar' 4P)ez, no my eco rcr
Attach additional sheets if necessary
Policy 3. Enhance visual quality and protect scenic resources throughout the Town of Southold. See
LWRP Section III—Policies Pages 6 through 7 for evaluation criteria
❑ Yes ❑ No X Not Applicable
Pott CY ; V d r A M. 71E,1Ir PleW Cr
Attach additional sheets if necessary
NATURAL COAST POLICIES
Policy 4. Minimize loss of life, structures, and natural resources from flooding and erosion. See LWRP
Section III—Policies Pages 8 through 16 for evaluation criteria
rVi
Yes ❑ No f4r Not Applicable
rnor ME O vv -FI`
C r
04 ,
�s v
Attach additional sheets if necessary
Policy 5. Protect and improve water quality and supply in the Town of Southold. See LWRP Section III
—Policies Pages 16 through 21 for evaluation criteria
Yes 1:1 No ®Not Applicable
Rd Qcy 9: zz- A ppe, nV 774 Is P&o 9-0 ef'
Attach additional sheets if necessary
Policy 6. Protect and restore the quality and function of the Town of Southold ecosystems including
Significant Coastal Fish and Wildlife Habitats and wetlands. See LWRP Section III—Policies; Pages 22
through 32 for evaluation criteria.
❑ ❑
,='Yes No Not Applicable
W=0 v
Attach additional sheets if necessary
Policy 7. ,Protect and improve air quality in the Town of Southold. See LWRP Section III — Policies
Pages 32 through 34 for evaluation criteria.
❑ Yes ❑ No g Not Applicable
Attach additional sheets if necessary
Policy 8. Minimize environmental degradation in Town of Southold from solid waste and hazardous
substances and wastes. See LRP Section III—Policies; Pages 34 through 38 for evaluation criteria.
ElYes El No 9 Not Applicable
PeL�e� P MIT A-AP4. r—O MIS tpeB )wail'
PUBLIC COAST POLICIES
Policy 9. Provide for public access to, and recreational use of, coastal waters, public lands, and public
resources of the Town of Southold. See LWRP Section III—Policies; Pages 38 through 46 for evaluation
criteria. nn
ElYes-1 No 19 Not Applicable
PD U CV 9 M67 APA-4. rO
Attach additional sheets if necessary
-WORKING COAST POLICIES
Policy 10. Protect Southold's water-dependent uses and promote siting of new water-dependent uses in
suitable locations. See LWRP Section III—Policies; Pages 47 through 56 for evaluation criteria.
❑ Yes ❑ No 54 Not.Applicable'
P011CY !Q N oar A&J. PRdv 'c_
Attach additional sheets if necessary
Policy 11. Promote sustainable use of living marine resources in Long Island Sound, the Peconic
Estuary and Town waters. See LWRP Section III—Policies; Pages 57 through 62 for evaluation criteria.
❑ Yes ❑ No ® Not Applicable `
Q � J Ld CA 7-I
•CJ S Ipw6 did-meo
612-
10-M Cr oral 41 VLM& 4IVA-lie
Attach additional sheets if necessary
Policy 12. Protect agricultural lands in the Town of Southold. See LWRP Section III — Policies; Pages
62 through 65 for evaluation criteria.
❑ Yes ❑ No)""'I Not Applicable
otI cy fZ Al a y' ,�/P�t: Td 7VAT PR 6TCE
Attach additional sheets if necessary
Policy 13. Promote appropriate use and development of energy and mineral resources. See LWRP
Section III—Policies; Pages 65 through 68 for evaluation criteria.
❑ Yes ❑ No JZ Not Applicable
�Qu cy !3 mar �p� M MIS Pio 9WC7_
PREPARED BY CJC TITLE DATE"
- - - - - --- --E--C--E--1
—E--C--E--l VS
COVE CONDOMINIUM OWNERS ASSOCIATI AUG 2 1 200
Amendments to Trustee Permit No. 9148
3outhu3d Town
AUTHORIZATION - Bard of Triistpes
TEN YEAR MAINTENANCE PERMIT FOR DREDGING
Wetland Permit for a ten(10)Year Maintenance Permit to maintenance dredge to three(3)feet below mean water
approximately 82 cubic yards from channel at entrance to association docking area,and as needed within the
docking area itself;dredge as necessary in the same areas to maintain width,depth and full accessibility of
entrance channel and docking area on a maximum of four(4)additional occasions during the next ten(10)years;
spoil will removed to an approved upland location for deposition. First spoil dredging may be used as backfill
landward of new low sill bulkhead.In accordance with the dredge plan prepared by Michael A.Kimack,received
on January 24,2018,and stamped approved on january24,2018.
AS BUILT LANDING,FIXED DOCK and FLOATING DOCK
For the existing 31.5 sq.ft.platform leading to existing 80.8 sq.ft.fixed dock with two(2)8"diameter pilings and
two(2)8"square pilings;existing 215.5 sq.ft.walkway;and 1,758.25 sq.ft.of an existing floating dock facility
with(1'5)8"diameter pilings securing the floating docks;with the condition of the installation of a silt boom
prior to construction that will retain all suspended sediments within the immediate project area;and that the
decking be replaced with thru-flow decking at time of construction if possible;and if not,at time of construction,
then when repairs are made;and as depicted on the site plan prepared by Michael A.Kimack,dated October 26,
2017,and stamped approved on January 17,2018.
REPACEMENT AND EXTENSION OF EXISTING WOOD BULKHEADS
A. North Bulkhead at Boat Dock
Remove approximately 116 feet of existing wood bulkhead.(25 ft.and 91 ft.)
Construct approx.116 feet of new Vinyl bulkhead with addition of one 12 foot return at northern end of 25 foot
section of new bulkhead(128 ft.total+/-).Set one(1)ft.higher than existing.Backfill with clean fill and restore
as proposed below.
B. South Bulkhead at Boat Ramp
Remove approximately 180 feet of existing wood bulkhead.
Construct approx.180 ft.of new Vinyl bulkhead with two returns,12 feet on the north end and 8 feet on the south
end for a total new length of approximately 200 feet,set one(1)ft.higher than existing.Back fill with clean fill and
restore as proposed below.
Construction
The new proposed bulkhead system will be constructed utilizing 9"x12 ft.pilings at 8 ft.OIC at approx.8 ft.below
grade,two(2)6"x6"stringers spaced accordingly,Shore guard 225 at 10 ft.in length at approx.6 ft.below grade,
a wood cap with 3"x 6"top clamp,3/4"x 10 ft.tie rods with horizontal lag log,with 8"backer pilings at 8 ft.
O.C. set approx.10 ft.back from main pilings.(See Cross Section on Site Plan))
C. PROPOSED PARTIAL LOW SILL BULKEAD W/FILL&PLANTING RESTORATION
Construct approx..180 ft.of new proposed Partial Low Sill bulkhead,(See Cross Section on Site Plan).Backfill
w/clean sand just below lower Vinyl sheathing.Maintain approx.2 tot slope from top of sloughed bank and then
flat to bulkhead.Install 2 layers of burlap,secure w/8"gaiv.pins,plant Spartina alterniflora @ one(1)ft.O.C.
throughout.(approx..2800 SF)
Restoration Landward of New Bulkheads
See Site Plan for Limit of disturbance Areas
Prior to clearing vegetation,remove and preserve to the extent feasible,wetland plants that can be removed,
preserved and replanted.Clear and excavate landward approx.10ft.from new bulkheads to place dead men and
tie rods approx..every 8 feet.backfill with excavated material and clean fill as needed.Proposed machinery to be
utilized would be small crawler backhoe with bucket.Restore wetland areas disturbed as follows:
A. Wetland limits of disturbance area approx..1025 SF.Subsequent to backfill, replant preserved wetland
plants prior to new plantings.Plant approx.70 three(3)gallon Baccharis plants at four(4)feet O.C.+1-,
Intersperse plants with approx..800 Spartina Patens at approx..one(1)foot O.C.
B. Wetland limits of disturbance area approx..1100 SF.Subsequent to backfill replant preserved wetland
plants prior to new plantings.Plant approx..75 three(3)gallon baccharis plants at four(4)feet O.C.
Intersperse plants with approx..900 Spartina Patens at approx..(1)foot O.C.
Note:Any disturbance to the intertidal marsh areas in sections A and B will be replanted with alterniflora
In accordance with the site plan prepared by Michael A.Kimack,dated June 19,2019 received on
and stamped approved on
k •, �' t.s � �4..'���+.�-c�- �,x :fly. � �-� �. :�, � tii
tom.., =y!. �. � � � 'l t � 1� `� l`�.+ `�i `'� �•
t.
:. � � 1". rte''` - �'� •---�.
. . AN
i r b
.. p
4•. y = i. �:r. 4'!a` .. fid".
.�ti3r6E'
IF �.
y � !
I ,
PROJECT DESCRIPTION CROSS SECTION: PARTIAL LOW SILL BULKHEAD CROSS SECTION: BULKHEAD
REPLACEMENT and EXTENSION OF EXISTING W006 BULKHEADClean sand fill set Just below lower sheathing
MG 2 1 2019
A. North Bulkhead at Boat Dock 4 Maintain 2 to I slope from bank to level
Remove approx..1J6 feet of existing wood bulkhead (25 ft.and 91 ft.) Spartina planted V O.C.w/two(2)layers of burlap
COVE CONDOMINIUM OWNERS ASSOCIATION
Construct appox 116 ft.of new bulkhead with addition of new 12 ft.i return at northern end of 25ft.section of new MAIN BAYVIEW ROAD, SOUTHOLD, N.Y. 11971
bulkhead.(128 ft.total).Set one(1)ft.higher than existing.Backfill with excavated and clean fill and restore as 4
SCTM: 1000-87-5-23.9 APPLICATION ID: 1-4738-01861/00014
proposed below
B.
South Bulkhead at Boat Ram
A and B MHW PROPOSED REPLACEMENT OF EXISTING BULKHEADS
Remove approximately 180 feet of existing wood bulkhead.
Construct approx.1 8d ft.of new Vinyl bulkhead with two returns,12 f�et on the north end and 8 feet on the south
end for a total new length of approximately 200 feet,set one(1)ft.hIg1her than existing.Back fill with clean fill and A MLW Backfill PROPOSED NEW BULKHEAD/PARTIAL LOW SILL, W/
restore as proposed below.
Spartina patens&Baccharis SAND BACKFILL, SPARTINA MITIGATION and
ConstructionB MLW
I I
The new proposed bulkhead system will be constructed utilizing 9"xII2 ft.pilings at 8 ft.OIC at approx.8 ft.below
REPLANTING LANDWARD DISTURBED AREAS
grade,two(2)6"x6"stringers spaced accordingly,Shore guard 225 a 10 ft.in length at approx.6 ft.below grade,
a wood cap with 3"x 6"top clamp,3/4"x 10 ft.tie rods with horizontal lag log,with 8"backer pilings at 8 ft. To; of Bulkhead:3 FT.above MLW DELINEATED BY M.A. KIMACK, DATED: MAY 8,2019
O.C. set approx.10 ft.back from main pilings.(See Cross Section) !
Every third vinyl sheathing set one(1)below top
SCALE: 1" 3 FEET REVISED
C. PROPOSED PARTIAL LOW SILL BULIKEAD W/FILL&PLANTING RESTORATION Top of lower sheathing(1)ft.below top of bulkhead
CERTIFICATION
MLW
Construct approx..180 ft.of new proposed Partial Low Sill bulkhead, See Cross Section).Backfill w/clean sand i I I HEREBY CERTIFY THAT THIS IS A TRUE COPY OF A PORTION OF THE
...............................
just below lower Vinyl sheathing.Maintain approx.2 tot slope from top of sloughed bank and then flat to
bulkhead.Install 2 layers of burlap,secure wl 8"galv.pins,plant Sparitina alterniffora @ one(1)ft.O.C. SURVEY BY YOUNG AND YOUNG, DATED JANUARY 4,1988.NO DETAILS
throughout.(approx..2800SF►
SCALE; 1' = 3 FEET
OR FEATURES WHICH BEAR UPON THIS APPLICATION AHS BEEN OMITTED.
Restoration Landward of new Bulkheads .0
Limit of Disturbance Areas
Prior to clearing vegetation,remove and preserve to the extent feasible,wetland plants that can be removed,preserved and
replanted Clear and excav te landward approx.10 feet of proposed new bulkheads to place dead men and tie rods approx. 41
every 8 feet.Ba ?excavated material and clean fill as needed.Proposed machinery to be utilized would be small 0. MICHAEL A. KIMACK,AGENT MAY 8, 2019
crawler backhoe with bucket.Restore wetland areas disturbed as follows:I
.001 Revised June 19, 2019
A. Wetland limits 4 disturbance area approx.1025 SF.Subsequent�o backfill replant preserved wetland plants priorB 75
to new plantingi.Plant approx.70 Three(3)gallon Baccharis pla�nts at four(4)feet O.C.+/-.intersperse plants 000 0
with approx.804 Spartina Patens at approx.one(1)foot O.C. : 400
B. Wetland limits of disturbance area approx.1100 SF.Subsequent I to backfill, replant preserved wetland plants prior
to new planting.Plant approx.75 three(3)gallon Baccharis pla6ts at four(4) feet O.C.+L-Intersperse plantscolkeir
with approx.904 Spartina Patens at approx.(1)foot O.C. CRF
Note:Any disturbance to the intertidal marsh areas 4
in sections A and B will tie replanted with alterniflora fie
C
*.I of
LEGEND
00P 4S.ap. qjL 2r 04!ZZ
10#14t.-*4
-Mm saw limits of MLW observed April 7,2019 @ 7:25 P.M.
00
Limits of MHW observed April 7, 2019 @ 1:30 P.M.
A Thm Vftttmd F4"—M 0 e 9 0 • Limits of Spartina Outcrops
Set by Cole 1!nv1roMMMt&1 S*MIC*S: 4112=18
Cedar Tree
Baccharis Bush Kpt *not
Locust Tree Lwe of wedwWls as dodem"d
by the Tnnto"of tho Town i
a 9VM town M.N. of soutbou
Cherry Tree
Bay Berry
MANIA
W'LL
laws
LK a tw I - -
Z
I~Pmw&is. SCALE: 1" = 30 FEET
_AA