Loading...
HomeMy WebLinkAbout44507-Z �O�SU PF Qjk Town of Southold 6/30/2020 o - P.O.Box 1179 lei Main Rd vi Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41224 Date: 6/30/2020 THIS CERTIFIES that the building COMMERCIAL ALTERATION Location of Property: 57225 Route 25, Southold SCTM#: 473889 Sec/Block/Lot: 63.-3-21.5 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/2/2019 pursuant to which Building Permit No. 44507 dated 12/11/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: interior alterations to existing restaurant as applied for. The certificate is issued to North Fork Rlty Assoc LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 20-66561 6/24/2020 PLUMBERS CERTIFICATION DATED 6/22/2020 e ge Fredr' s Au o Signature t TOWN OF SOUTHOLD Gy BUILDING DEPARTMENT y TOWN CLERK'S OFFICE o . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 44507 Date: 12/11/2019 Permission is hereby granted to: North Fork Rlty Assoc LLC 57225 Route 25 Southold, NY 11971 To: construct interior alterations to existing restaurant as applied for. At premises located at: 57225 Route 25 SCTM # 473889 Sec/Block/Lot# 63.-3-21.5 Pursuant to application dated 12/2/2019 and approved by the Building Inspector. To expire on '6/11/2021. Fees: NEW COMMERCIAL, ALTERATION OR ADDITIONS $250.00 CO -COMMERCIAL $50.00 Total: $300.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the budding. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957)non-conforming uses, or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 J, Date. New Construction: Old or Pre-existing Building: (check o e) Location of Property: 5712:) Kn� a House No. Street C Hamlet Owner or Owners of Property: CI&A CL Suffolk County Tax Map No 1000, Section 65 Block Lot �� •�_ Subdivision Filed Map. Lot: Perrmt No. _I' -1✓0(fG�-� Date of Permit. Applicant: t Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for. Temporary Certificate Final Certificate: (check one) Fee Submitted: $ y� plicant Signature ,I i Owner's Authorization Statement I esiding at 57X!J Mj f&'Rd,Sju&Wo hereby s authorize Andrew V.GiarnLertone &Associates Architects 62 Elm Street Huntington,NY 11743 to act as the applicant on my behalf for the Town of Southold. S%VOEn to before me this OC day Of .2019 Notary Public Signature Si ture of Owner 0MBOA Nowy 1'ablic.Stats ofNes Yack No.01906376473 QwliBad in SuffiW t arty Cemmimiea Suras June 11,2022 1 Certificate of Compliance ............................................................ ............................................. ....................................................................-..... .... CERTIFIED ELECTRICAL INSPECTIONS, INC. 188 PARK AVENUE AMITYVILLE, NY 11701 - t , ',~ I / k,� P: (631) 598-5610 f V 1 . ' C ' ................................................................... . ............................................... .............................................................1...�:... , ) CERTIFIES THAT r JUN 2 9 Q20 Upon the application of Upon premises owned by G & S Electric North Fork Table & Inn LLC. PO Box 215 57225 Main Road Southold, NY 11971 Southold, NY 11971 Located at: 57225 Main Road, Southold, NY 11971 Application Number*: 20-66561 Certificate#: 20-66561 Electrical License#: 578-ME/31568-ME Section: Block: Lot: Building Permit#: 44507 Described as a Commercial occupancy, wherein the premises electrical system consisting of electrical devices and wiring, described below, located in/on the premises at: Renovation of 1st Floor Dining Room/ Kitchen A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed herein, was conducted in accordance with the requirements of the applicable code/or standard promulgated by the State of New York, Department of State Code Enforcement and Administration, or other authority having jurisdiction, and found to be in compliance therewith on the 24th day of June 2020 Name QTY Special Receptacle -20 Amp, 220V 2 Duplex Receptacle -20 Amp, 120V 35 HW Heater Circuit-20 Amp, 120V 1 Transformer-20 Amp, 120V 2 LED LV Fixture- 12 V 26 Power Panel - 100 Amp, 208 V, 3PH 1 Exhaust Fan - 15 Amp, 120V 5 LED 2 x 2 Light Fixture - 15 Amp, 120V 24 Electrical Inspector: Anthony Giordano a00 cR'..........;:s,, _' :APPRDV-7E,D o ��OOruamnmaao"�\ - This certificate is not valid unless raised seal is present. Certificate of Compliance ................... .. ...................................... ............................. ............................................. ....................................... CERTIFIED ELECTRICAL INSPECTIONS, INC. 188 PARK AVENUE AMITYVILLE, NY 11701 P: (631) 598-5610 ...................................................... ....................................... . ................................................................ .................... CERTIFIES THAT Upon the application of Upon premises owned by G & S Electric North Fork Table & Inn LLC. PO Box 215 57225 Main Road Southold, NY 11971 Southold, NY 11971 Located at: 57225 Main Road, Southold, NY 11971 Application Number#: 20-66561 Certificate#: 20-66561 Electrical License#: 578-ME/31568-ME Section: Block: Lot: Building Permit#: 44507 Name QTY AC Blower- 15 Amp, 240V 2 AC Condenser-20 Amp, 240V 1 AC Condenser- 30 Amp, 240V 1 Carbon Monox-15 Amp, 120V 1 Comb Emerg/Exit-20 Amp, 120V 5 Compressor-20 Amp, 120V 4 Cooler Drawer Circuit-20 Amp, 120V 1 Dimmer-20 Amp 120V 12 Emergency Light-20 Amp, 120V 1 Exhaust Hood - 15 Amp, 120V 2 GFI Circuit Breaker-20 Amp, 120V 2 Electrical Inspector: Anthony Giordano \\`\��UIUII�I'17ifplgj�/'i 01 ..... . \\`• This certificate is not valid unless raised seal is present. Certificate of Compliance ..................................I.. ....................... . .................................................................................................... ..... .. CERTIFIED ELECTRICAL INSPECTIONS, INC. 188 PARK AVENUE AMITYVILLE, NY 11701 P: (631) 598-5610 ................................. .................................. ............................................. . ............................................. ............. CERTIFIES THAT Upon the application of Upon premises owned by G & S Electric North Fork Table & Inn LLC. PO Box 215 57225 Main Road Southold, NY 11971 Southold, NY 11971 Located at: 57225 Main Road, Southold, NY 11971 Application Number#: 20-66561 Certificate#: 20-66561 Electrical License#: 578-ME/31568-ME Section: Block: Lot: Building Permit#: 44507 (dame QTY GFI Receptacle -20 Amp, 120 V 8 Heat Lamp Fixture-20 Amp, 120V 1 LED LV Recessed Fixture- 12 V 54 Meter-600 Amp, 208 V, 3 PH 1 Service Disconnect- 100 Amp, 208 V, 3PH 1 Service Disconnect-200 Amp, 208 V, 3PH 2 Special Receptacle-30 Amp, 220V 2 Switch -20 Amp, 120V 19 Walk-in Refrigerator Circuit-20 Amp, 120 V 1 Electrical Inspector: Anthony Giordano •..o% _�APPIZrJ`JEDjo_ " ummIuu���\`\`� ' This certificate is not valid unless raised seal is present. Town Hall Annex 'Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959Q` BUILDING DEPARTMENT TOWN OF SO TII'HOLD CERTIFIC -TION Date: Building Permit No. Owner:__ .�� `` •_�,-l�E (Please print) Plumber: ���s P fi�dll (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. tl (Plumbefs Signature) Sworn to before me this ��- day of "t' , 20 ROBERT F MARKS NOTARY PUBLIC-STATE OF NEW YORK No.01 MA6364702 Qualified in Suffolk County My Commission Expires-0.9-18-2021 Notary Public,_ L J �County a0E SOGIy # # TOWN OF SOUTHOLD BUILDING DEPT. 765.1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I ULATIOWCAULKING [ ] FRAMING/STRAPPING [ FINALCOOIK . N'IiiTS . [ ] FIREPLACE�& CHIMNEY - [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: sw-C& _ InakellG n -tt Ao e �PAAA I � - - J DATE Y INSPECTOR 63-3-21 OF SOGIyo� # # TOWN OF SOUTHOLD BUILDING DEPT. - �o . �o �yco 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING FINAL [ ] FIREPLACE & CHIMNEY [ J FIRE-SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: 6��,Z DATE INSPECTOR i hO�aDE SOUTyO� �./ * # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION - [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [FINAL [' ] FIREPLACE & CHIMNEY [!p� FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE-RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: vi /f ,�✓ dam" . �/1N>c 11,-9,W14ZX OL 1, DATE ?4Z;26 INSPECTOR r*a C-1,A-14&E'R`r.OW E C I'AT F ARC. El Il' 1^ C !' S Architectural Certification North Fork Table Restaurant and Inn TOS Permit Number 44507 To:Town of Southold Building Department Attn:Michael Verity; Building Inspector Re: North Fork Table Restaurant and Inn Building Permit Number 44507 Dear Mr.Verity, Please be advised that I am a Licensed Architect, Registered in the State of New York(Arch. Reg.number 020804).As such I have Prepared Plans for the Minor Interior Alterations to the Town of Southold as well as Kitchen Renovations to the Suffolk County Dept of Health Services. During the Course of Construction, I have had.the opportunity to closely observe the Course of Construction at the subject property in general,and specifically the following systems: • Structural Modifications,as well as Minor Framing changes, including any and all remedial Structural work executed,as required. • Rough Plumbing work in the Kitchen area, Relocated Bathrooms,and relocated Bar Areas. • Finished Plumbing work in the Kitchen area, Relocated Bathrooms,and relocated Bar Areas. • Insulation in the perimeter walls,floor,and ceiling of the renovated First Floor areas- • Fire Safety separations as follows: o Ceiling Between the Dining Area and the Inn Sleeping rooms above(i Hour Continuous Fire Separation) o Walls and Door surrounding the Entry Lobby,and the Restaurant and Bar area (2 Hour Continuous Fire Separation) Accordingly to the best of my Professional Knowledge and Experience, I hereby certify that the General Building Construction and specifically the system listed above, have been installed in strict conformance to the Approved Plans on file with the Town of Southold,the Suffolk County Dept of Health Services, and the Uniform Building Code. D t� >l�Cy���C• i �a •:Nltl I.r 1 1•I bi r, n e .q 1Y• h-Oj'e o , LA Pre �4 AV GQGiambertonearchitects.com 1 62 Elan Street,Huntington, NY 11743 Tel: (631)367-®050 o Fax(631)357-6636 O AVG@GiambertoneArchitects.com Food Establishment Inspection Report Suffolk County Department of Health Services — Page 1 of 1 360 Yaphank Avenue Suite 2A Yaphank,NY 11980 Date: 05/22/2020 631-852-5999 � • := www suffolkcountyny.gov/health Establishment Name Establishment Address City/State Zip Code Telephone THE NORTH FORK TABLE&INN 57225 MAIN RD SOUTHOLD,NY 11971 (631)765-0177 Facility ID# Permit Holder Purpose of Inspection Inspection Result FA0002521 NOFO T&I,LLC Premise/Facility Inspection Permit Issued Owner Owner Address Permit RestrictionsCapacity NOFO T&I,LLC 57225 MAIN RD, SOUTHOLD NY 11971 CV D G 64 seats Inspection Violations Comply By Date No violations cited —Overall Inspection Comments Pre-operational inspection was performed virtually on 5/22/20 Establishment was built in substantial compliance with approved plans and may open when ready Notes Splash guard must be installed between the mop sink and adjacent shelving Prior to opening the interior of the establishment to patrons,construction of the bar,service are and patron restrooms must be completed A second pre-operational Inspection is required prior to these areas being used OK TO ISSUE PERMIT EE0000529-Nadine Roe 'The Items noted above are violations of applicable laws,rules and regulations found during an Inspection of the operation of the facilities In this establishment which must be corrected as indicated Failure to comply may result in the initiation of legal action against this establishment as provided for in Articles 2 and 13 of the Suffolk County Sanitary Code Including a hearing,possible suspension of your food operation,and/or the publication of the violation and fines" _ J , 5002 v5 �uFrol CCK unri ez�urve ��. mes�ronwmin ss ac"'en"'''A"'�' WFFCCKCOCNTY OEGIK21FMi W NEIIL1NSHiVK£S Food Establishment Inspection Report Suffolk County Department of Health Services i Page 1 of 1 360 Yaphank Avenue Suite 2A Yaphank,NY 11980 Date: 06/17/2020 631-852-59994 www suffolkcountyny.gov/health V Establishment Name Establishment Address City/state Zip Code 7(631)p!7,65-0177 one THE NORTH FORK TABLE&INN 57225 MAIN RD SOUTHOLD,NY 11971 Facility ID# Permit Holder Purpose of Inspection Inspection Result FA0002521 NOFO T&I LLC Reinspection/Follow-up Brought to Compliance Owner OwnerAddreas Permit Restrictions Capacity NOFO T&I LLC 57225 MAIN RD, SOUTHOLD NY 11971 D 64 seats Inspection Violations Comply By Date No violations cited. —OverallInspection Comments Re-Follow-up Preoperational Inspection Bar and patron restrooms have been installed in accordance with the approved plans These areas may now be used. i EE0000529-Nadine Roe "The items noted above are violations of applicable laws,rules and regulations found during an Inspection of the operation of the facilities in this establishment which must be corrected as indicated.Failure to comply may result in the Initiation of legal action against this establishment as provided for In Articles 2 and 13 of the Suffolk County Sanitary Code including a hearing,possible suspension of your food operation,and/or the publication of the violation and fines" 5002 v5 STEVEN RELONE , GREGSON H PIGOTf MD,MPH SUFFOLK COUNTY EXECUTNE COMMISSIONER SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES CERTIFICATE OF APPROVAL OF FOOD SERVICE ESTABLISHMENT FOR CONSTRUCTION, ALTERATION OR REMODELING Applicant Establishment Location NOFO T&I LLC 57225 Main Road D\B1A: The North Fork Table & Inn Southold, NY 11971 Approval is issued under the provisions of Article 13, Section 1304 of the Suffolk County Sanitary Code for: 1) New Application 2) X Remodeling ' THE FOLLOWING CONDITIONS APPLY: 1) PROPOSED CONSTRUCTION IS IN CONFORMITY WITH THE PLANS AND SPECIFICATIONS APPROVED BY THIS DEPARTMENT. 2) REVIEW IS BASED UPON THE APPLICATION, PLANS AND MENU YOU PROVIDED. ANY CHANGES REQUIRE WRITTEN APPROVAL FROM THE DEPARTMENT OF HEALTH SERVICES BEFORE THE CHANGES CAN BE MADE. 3)THE APPLICANT MUST CONTACT THE FOOD CONTROL UNIT AT 631-852-5873 TO ARRANGE AN INSPECTION OF COMPLETED CONSTRUCTION PRIOR TO OPERATION. 4) THIS CERTIFICATE IS NOT A PERMIT TO OPERATE 'A FOOD SERVICE ESTABLISHMENT. OPERATION'WITHOUT A SATISFACTORY PRE-OPERATIONAL INSPECTION AND/OR A PERMIT TO OPERATE WILL RESULT IN LEGAL ACTION. 5) PLEASE MAINTAIN YOUR SET OF APPROVED PLANS AT THE ESTABLISHMENT FOR USE DURING CONSTRUCTION AND INSPECTIONS. 6)THIS APPROVAL DOES NOT CONSTITUTE APPROVAL BY ANY OTHER STATE OR LOCAL REGULATORY AGENCY. 7) THE APPROVAL TO CONSTRUCT IS VALID FOR 2 YEARS. AN EXTENSION MAY BE GRANTED UPON WRITTEN REQUEST WITHIN 30 DAYS OF EXPIRATION. 8) THE APPLICANT SHALL ASSURE CONFORMANCE WITH THE FOLLOWING AMENDMENTS TO PLANS AND SPECIFICATIONS: ➢ Provide adequate splash guard protection: o Between dishwasher drain board and directly adjacent storage shelf o Both sides of mop sink ISSUED FOR THE CO IONE -HEALTH DESIGNATE ENTATIVE T TRAINING AND PLAN REVIEW UNI 1'360 Yaphank Ave Yaphank,N Y 11980 (631)8 2 33 06/10 FIELD INSPECTION REPORT DATE COMMENTS ro - FOUNDATION (IST) H ------------------------------------- FOUNDATION (2ND) o CIO 1 � ROUGH FRAMING& PLUMBING ' - r INSULATION PER N.Y. y STATE'ENERGY CODE v l mmc ..�✓✓ mail, Vtvmh� FINAL ADDITIONAL COMMENTS ® as 4 b 0 H x d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans E 7--Et-.m(631)765-1802 Planning Board approval FAX:(631)765-9502Survey Southoldtownny.gov PERMIT NO. L4 Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined 20 - z Single&Separate rr , Truss Identification Form Storm-Water Assessment Form 1q 111 e 2 2019 contact: AUS a0eM-=c5 Approved 20 Mail to:A, DE1JNl5�P f Disapproved a/c - (O2Et>?15T 1NYt�1`I`r'ft ,W. � Phone: fn3�-3(01-0�5� Expiration 20 s drudi�r5k �t�+�ia-�rrr�ctrd�'► S.cmn Bui rng Inspector APPLICATION FOR BUILDING PERMIT Date ,20 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of pians,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building co ,housing code,and regula' s,and to admit authorized inspectors on premises and in building for necessary inspections (Signature of a pli ant or name if a corporation) 2S Ya'1 (Mailing address of applicant) State whether applicant is owner,lessee,agen rchitect,engineer,general contractor,electrician,plumber or builder t� Name of owner of premises C-; 11 e (As on the tax roll or latest eed) If applicant is a corporation,signature of duly authorized officer (Name and title o co oIrate fficer Builders License No. c2 �D' S SCt(V�GCS�� Plumbers License Normo ' o?-X4 1P Wobeiri O 6ri CA A ,, rte."Irrtc.. Electricians License No. O— !t',k�c- Z,,ocQ Other Trade's License No. 1. Location of land on which proposed work will be done: 57 225- M Ai lu F-6 i�D U I qao House Number Street Hamlet County Tax Map No. 1000 Section (O3 Block 3 Lot �'S Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy PC 0'U 91y3T b. Intended use and occupancy f eq_F/tp f2A113 3. Nature of work(check which applicable):New Building Addition Alteration Repair `t� emoval �.5AW✓Demolition ✓ Other Work (Description) 4. Estimated Cost ( 1� Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage,number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. ei{ztuY2t 1�erngt� r�c� p 7. Dimensions of existing structures,if any:Front I I t'DII2 Rear Depth 5-il 14011 Height ( to t Number of Stories 3 Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front 2-10,90 Rear 140(1 15 Depth 'ZG1 l boa I0.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated #1?�, 9.80 12.Does proposed construction violate any zoning law,ordinance or regulation?YES NO)'(- 13.Will lot be re-graded?YES_NO X Will excess fill be removed from premises?YES NO 14.Names of Owner of premises Address Phone No. Name of Architect W y .66 S%beAddress G2ELM, 60i�Ng A Phone No (A 1.3(aT 0050 Name of Contractor Address IPhone No. 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES • NO *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO *IF YES,PROVIDE A COPY. STATE OF NEW YORK) Q� SS: COUNTY OFJ 0)L being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, i+ ..: (S)He is the (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Swo before me thi -day of 44-- C�r 20LE 84 -aU_.lstQ.. ��vt�n.y Notary Pub c Signature of Appl c r SUFFOLK COUNTY DEPARTMENT OF HEALTH SERVICES CERTIFICATE OF APPROVAL OF FOOD SERVICE ESTABLISHMENT FOR CONSTRUCTION,ALTERATION OR REMODELING Applicant Establishment Location NOFO T&I LLC 57225 Main Road D1B1A: The North Fork Table & Inn Southold,NY 11971 Approval is issued under the provisions of Article 13, Section 1304 of the Suffolk County Sanitary Code for: 1) New Application 2) X Remodeling THE FOLLOWING CONDITIONS APPLY: 1) PROPOSED CONSTRUCTION IS IN CONFORMITY WITH THE PLANS AND SPECIFICATIONS APPROVED BY THIS DEPARTMENT. 2) REVIEW IS BASED UPON THE APPLICATION, PLANS AND MENU YOU PROVIDED. ANY CHANGES REQUIRE WRITTEN APPROVAL FROM THE DEPARTMENT OF HEALTH SERVICES BEFORE THE CHANGES CAN BE MADE. 3)THE APPLICANT MUST CONTACT THE FOOD CONTROL UNIT AT 631-852-5873 TO ARRANGE AN INSPECTION OF COMPLETED CONSTRUCTION PRIOR TO OPERATION. 4) THIS CERTIFICATE IS NOT A PERMIT TO OPERATE A FOOD SERVICE ESTABLISHMENT. OPERATION WITHOUT A SATISFACTORY PRE-OPERATIONAL INSPECTION AND/OR A PERMIT TO OPERATE WILL RESULT IN LEGAL ACTION. 5) PLEASE MAINTAIN YOUR SET OF APPROVED PLANS AT THE ESTABLISHMENT FOR USE DURING CONSTRUCTION AND INSPECTIONS. 6)THIS APPROVAL DOES NOT CONSTITUTE APPROVAL BY ANY OTHER STATE OR LOCAL REGULATORY AGENCY. 7) THE APPROVAL TO CONSTRUCT IS VALID FOR 2 YEARS. AN EXTENSION MAY BE GRANTED UPON WRITTEN REQUEST WITHIN 30 DAYS OF EXPIRATION. 8) THE APPLICANT SHALL ASSURE CONFORMANCE WITH THE FOLLOWING AMENDMENTS TO PLANS AND SPECIFICATIONS: > Provide adequate splash guard protection: o Between dishwasher drain board and directly adjacent storage shelf 0 Both sides of mop sink ISSUED FOR THE CO IONERF HEALTH DESIGNATE ENTATIVE T TRAINING AND PLAN REVIEW UNIT 360 Yaphank Avc,Yaphank,N,Y 11980 (631)8a2-58 3 06/10 _ � 8 �L z p, - em § P sun 6 connsEssoB t.oranoxsJeo '' 'Muna: a as 3 s-r I e „ PCL -=T� = ® 3! zx hrI 00 32 L AIM ,2 it �J ' /tor, ' ' u, r-U5' - I E 1 ea 4ED cl:D A 5 I' xD P yl- ,, Iw_xuc0 roup w ro/tr otunrtn,w y CID1375 DrmdwDy,Suke 502 New York,Nen York]0018 T<1(x12)1N-0008 F.(21241-0057 - - 3 -- � xtna,l]kouverss/'smric0 com O - 3 ^y �s�nw>t®-� B 12-16-2018 Is 3 ,4EP C a A ON 01-N— '+ �',a A DAY.NC ree Dab 0-2} •ryl*�� ____ r W19 _ R��mc art q�w0 D,-J,-RD - 8u£AEvsONJr D3-BY-] v rpyi�c OR-00-2 of 0-30 E-1 av_i Q rnarr �t� f�'y , i,•.l'`>,�3* B'3 l ____ ...� � ❑ ECT eis r a oll O O 4! C} Y.j Z Z Aa , Ba w Ba w BI cco FEO E 6 2P26 N F„ Nm nuBBevurtoxs�..' 1A 9um'OLK CA]JNTY BEPamA7t'1•ta1.'NT of �acrxsaors I sraie oro„nr-,.a- C6 FlRSt FL RSt FLUOR _ ,�{f y.�r o�—+�d s/"k �•�� EQUIPMENT PLAN DRAWN BY K KAVANAUGH It"WNG NUMBER FS 2.® ( NOTE FIDOR P4NSORTAPlFDFROM IXtAYAHW FROOULED BY ANDgCWV fy�v��aw-+xim�n�rla@,a� URAW NOS Wi00UCED DY 6AYTE11 GLWBFATONE AFSEUCI�TEK IEyx"��u V LLY� COEN0.1AE90RTEOJKNIIMYM]030. MCHGFLTS DSTLUfGtlRU4R1']2010 Y UdR�4 tON ��� f1EMM HPNDSMK Q- — -- �_ PWGC m CLIENT DR ONS 90LUT10N3 t-t5H GUMDS - r� ® r LL ftl�' _ P W GROSSER CONSULTING ENGINEER r Uue AND HYDROGEOLOGL4T,P C J CB) �rE,:S'�a CONSULTNii6 ...til 9 Sae+NmK �1 D _ w;i" 9CE cLTO 6E SElF ❑ OSINGRtT+� ® -+. G Ilttt�Jlll��JJll..11il - — TWAIGifGTEA ® O — r I C(7 OTJ E FIRST FLOmRPLLAN 6Gstt Nrn EXISTING CELLAR PLAN u yc wD cnE � _ nlHomo ANOREWV GUIieERTONE 6ASSDCUITES 62 Et915TREET HUNRNGTON,NEW YORK 11743 OI or o 03 0 EDz n o - © o r M ® [A El 0 NORTH FORK N"" TABLE AND INN ,r ,� ,x ,,r. ,,n- .n -,J� _ 51II6 MAM ROAD Qff 60UTHOLD,TOWNOF13OUTHOIO SUFFOLK COUNTY,NEW YORK 11971 rF kap __ D.tl µ ate, J PROPOSED I RISER DIAGRAM PLUMBER RISER DIAGRAMTE ECNE NT 9 9FIMHOON OOOR9ME iUSE 9ELFDLOANG 3 aLL FOOD REM9PREWSUIKM1NOIMLLBETRANOPIXiTEOW COVERED KLL SiH6H 116CE0UIPFED YRIH S„A:N DDAPO9 B-100 pa ' i 'NNS�I�AOu�l91 NE�RSr TO C�O�IY OW FNEkhN DNNN99HP11 NAVEPN � 6 O RM YAIHSODH6 RE0DIRENEMS " 1;� �� AVG1804 119 tlg moo•, .��� � moo...... .. ..... ��.. .. ten • moo. �� ........ .. ..... ... . ..... ..... .. MGM :,' Mon �o > moo.....', �n v� moo• �� mo r� oamm _ ,�. •-�,',...ice „.. , m ou :s RIMmolm : mo mu Imo am oo Inrnn�mnnn� amo Mom .._.. moo., � I Scott A. Russell ,��°� � STO)KI��1 WA' IEIK SUPERVISOR ' NAG 1NA\�G IEAMIIEN T SOUTHOLD TOWN HALL-P.O.Box 1179 � ' 53095 Main Road-SOUTHOLD,NEW YORK 11971 tiyt Town of So u th o l d CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOZES THIS PROJECT INVOLVE ANY OF THE FOLLOWING: Yes No (CHECK ALL THAT APPLY) ❑ A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑ C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑ D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑ E. ite preparation within the one-hundred-year floodplain as depicted on FIRM Map of any watercourse. ❑ F. Installation of new or resurfaced impervious surfaees of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT (Property Ow es,;n Professional, nt.Contractor,Other) a.0 T.M. #: 1000 Date V �3 District 2 � 2 Z 2© NAME t �( �' Section Block Lot _ _00 FOR Bli1LDI\G DEPARTMENT USE ONLY Contact Information ✓ c �✓�/ vr,0_5 b f elrpione Nw�M.n Reviewed By. — — — — — — — — — — — — — — — — — — Date Property Address / Location of Construction Work- — — — — — — — — — — — — — — — — — �2� „�/! ❑ Approved for processing Building Permit. vl �Lt Stormwater Management Control Plan Not Required ® Stormwater Management Control Plan is Required (Forward to Engineering Department for Review) pFORM SMCP-TOS MAY 2014 PVVW CLIENT DRIVEN SOLUTIONS December 2, 2019 Andrew V. Giambertone&Assoicates,Architects, PC 62 Elm Street Huntington,NY 11743 Dear Mr. Giambertone, P.W. Grosser Consulting, Inc (PWGC)was retained by the prospective purchaser of the property to evaluate the need for Suffolk County Department of Health Services (SCDHS) permits for the proposed changes to the existing restaurant. Currently PWGC understands that a building permit is being filed to remove and relocate interior walls within the existing dining area of the restaurant.As these modifications do not increase the overall square footage of the building or increase the approved seating of the restaurant SCDHS permitting is not required. PWGC has reviewed SCDHS Guidance Memo # 10,which also indicates that a permit is not required for the proposed interior alteration as the use is not changing. To confirm the above, PWGC spoke with Varughese George WG",who is an assistant public health engineer for the SCDHS Office of Wastewater Management.Mr. George indicated that our understanding was correct and that a permit application to SCDHS Office of Wastewater Management is not required for this type of interior alteration. Very Truly Yours, Bryan Grogan, PE Vice President P.W. Grosser Consulting, Inc. P.W. GROSSER CONSULTING, INC. PHONE: 631569.6353 630 JOHNSON AVENUE,STE7 P.W GROSSER CONSULTING ENGINEER & HYDROGEOLOGIST, P.C. PWGROSSER.COM BOHEMIA, NY 11716 LONG ISLAND - MANHATTAN - SARATOGA SPRINGS - SYRACUSE - SEAT T LE - SHELTON ANDREW V. GIAMBERTONE & ASSOCIATES RCHITECTS, F.U. TRADITIONAL BUILDING DESIGN 62 ELM ST. HUNTINGTON,NEW YORK 11743 LETTER OF TRANSMITTAL TEL:(631)367-0050•FAX:(631)367-6636 DATE: December 2,2019 Town of Southold-Building Department ATTN: Michael J. Verity TO: Town Hall Annex Building Chief Building Inspector 54375 Route 25 JOB#: P.O.Box 1179 19-012 Southold,NY 11971 RE: North Fork Table 57225 Main Road H WE ARE SENDING YOU: M Attached ❑The items listed below,under separate cover via ❑Shop drawings ❑Prints ❑ Plans ❑Samples ❑Specifications ❑Copy of letter ❑Change order ❑ VIA: Hand Delivery TRACKING#: COPIES DATE NO. DESCRIPTION 1 12/02/2019 - Building Permit Application 1 12/02/2019 - Home Improvement License,Photo ID 4 12/02/2019 - Construction Documents—Existing Conditions EX1,Demolition Plan D1, Proposed Floor Plan A2---Sealed and Signed 1 12/02/2019 - Letter from PWGC-Bryan Grogan-PE regarding Suffolk county Dept. of Health Services DEC - 22019 civ t' am�e►� � ar��i���� , ryy THESE ARE TRANSMITTED as checked below: M For approval ❑Reviewed&Approved ❑ Resubmit _copies for approval ❑For your use ❑Approved As Noted ❑Submit _copies for distribution ❑As requested ❑ Returned For Correction ❑ Return _corrected prints M For review and comment ❑Rejected ❑ Prints returned after loan to us Hello Michael, Attached please find our building permit submission for a minor interior to the first floor at North Fork Table 57225 Main Road Southold,NY. Please let us know if there's anything further you may need. Thank You. ❑ For bids due M Letter of Denial REMARKS: COPY TO: file SIGNED: Dennis Radzinsky If enclosures are not as noted,kindly notify us at once. Jarski, John From: Verity, Mike Sent: Monday,June 29, 2020 2:57 PM To: Jarski,John Subject: FW:Architectural Certification for the North Fork Table CO Application-57225 Main Rd From:Andrew Giambertone [mailto:AVG@GiambertoneArchitects.com] Sent: Monday,June 29, 2020 2:34 PM To:Verity, Mike<Mike.Verity@town.southold.ny.us> Cc: Dennis Radzinsky<DRadzinsky@giambertonearchitects.com> Subject: FW:Architectural Certification for the North Fork Table CO Application-57225 Main Rd Good Afternoon Mike, Hopefully the third times the charm.Attached here-in is the same e-mail I've tried without success to send twice before but was rejected by your server as too large. So we have now provided a Drop Box for the attachments. Please verify receipt, and that you can open the file. Fingers Crossed,Andy Drop Box Link: https://www.d ropbox.com/sh/ancom2546t5oxih/AADJg6uBkOklOZ13MtXH FS7oa?dl=0 Andrew V. Giambertone,AIA President AVG@GiambertonearcEtects.com Andrew V. Giambertone & Associates, Architects, PC 62 Elin Slrcet, E-9unfington, iacw York 11743 llhune: (631) 367.0050 Fax:(631) 36 .6636 Tla+mrilgte its tot ehr tumcd srtipitm otdy.Ii nral e+nuirl onridtniiil,1iarpm:14eY•nr N-pllj,ctiVsSq..rJ info:rzuume, If the rcttict of that nw_%sat;c 64 mre the intsndcd rcc4kni,ym=c hereby'nputicd that hny disyemiauuuo,dntrihuii=.w copy±ngof this eommunireuon to setisefy Trc h1t.1qM•If yam Iu+r tctti.�d thla crxtsertt n cae+rt in emir,lylrast ilofff�uv imratnii,etly In,"mul,-td deklc;lir oit of al mnsai;c Grnat y+xir cnnaixutcr, V[e s±ere a rite nrht to¢tton:;o±all cat±ail eunatitotiattoe7s .Vthxtth ke►xLe:e thts emztl asd artr uirtch• ml ce i arr Niru%fetr,u�eye rf[iE y-u3rant5�r Phu it if sirua-frrt, rot.any ucc•, Good Afternoon Michael, I hope this finds you well. At this point we have completed our work at the North Fork Table Restaurant and Inn.Towards that end, I am herewith providing you with copies of all Inspections and approvals from: ? Suffolk County Dept. of Health Food Services Unit i ? Town of Southold Building Department ? Town of Southold Fire Marshall ? Third party Electrical Inspectors Additionally I will provide you photographs of the Underground roughing installation and structural modifications for the Kitchen and Dining Room respectively, a summary of the individual Fire ratings and the actual Professional Architects Certification. 'Accordingly, please find attached above: 1. Town of Southold Building Permit#44507 2. Suffolk County Dept. of Health Services Food Establishment Inspection Report 3. Suffolk County Dept. of Health Services Food Establishment Inspection Report- Final Permit 4. 613/20-Town of Southold Inspection For Hood Assemblies (Bob Fisher) 5. 6/3/2o-Town of Southold Inspection For Fire Safety Inspection Final (Bob Fisher) 6. 6/22/20-Town of Southold Inspection Final for Commercial Alterations (John Jarski)and the required documents: a. BOH Final Food Service Permit(attached above- Item 3) b. Electrical Certificate from Certified Electrical Inspectors (3 attached Above) c. Architectural Certifications for Plumbing, Insulation and Structure(pasted below) d. Insulation Kits for both Bathrooms(photos attached above) e. Fire safety Inspection Final (Attached above Item 5) Additional Items: Photographs of the following: ? Structural Modifications per approved plans (4 Photos) ? Rough Plumbing Installation (3 Photos) ? Insulation kits for ADA complaint sinks Architectural Certification: Attached Above(last Item) Therefore based upon these submitted Items, and on behalf of the North Fork Table Ownership I respectfully Request that the Town of Southold issue a Certificate of Occupancy for this Project. Respectfully Requested, Andrew V. Giambertone Andrew V. Giambertone,AIA President AVG@Giambertonearchitects.com 2 Andrew V Giambertonc & associates Architects PC X22 Elm Simet,liuntingtrnn, Nlcw fork- 1174.3 Phone- (631) 3671090 Fax-.(631)•367,6636 INS annity;r n tot the mAmcd m6pitni dm]g,Ir m4rcanctin cnmfid tmtiil,jwcjnrisaaa}.x Nally giiai ;td iitfct+rutirnA, ff vE+'c tea+kr of thio meesa}c is not the iritcnded rccs`pi�nt,}vert we harbv taotitied that am,dimcmiamian,&t+ihutiaa,os eapyingof this aatnmunieaaon la asticat}pr.:lt�te9trJ.Of you ha+r,rcaivid e5la ernnmwi�raa+ei in etraq f+leau is*at(f}•w�Frnensstiatrly�}ty'einsfl urr,9,Iateie SliFrer'�nYI mcasal;c frattt}'rwt'eatnpu!cr, VCc iciervr the rt�jet tu rr.�ectti'u all anal eatrm+ati<atiuns. e1lehaugh rsx 6elicxs t2sia catiati and art}•attack= _ mcntc at¢•iiruc•fnpt,uF.ln ep;+5�+unntFt elrat is h eitu�•ft�e,in,9 s� ,rpt tt y IishiliTy i+yr sny R•'Fsa ax dana}�t in�m,,ert+etn isc nse. 3 Suffolk County Dept.of Labor, Licensing&ConsuDner_Affffairs- HOME IMPROVEMENT_ LICENSE- Name ICENSEName .DOE GENTILE Business Name PCI SERVICESINC This certifies that the ; bearer is duly licensed License Number H-23426 by the County of Suffolk Issued: 06/01/1994 - -- Commissioner Expires: 06101/2020 6 7 ;4 `r wK NAM-2 ty" ExecuHtre�g Office'of Consumer Affai�s Suffolk b-'an , VETERANS I�IEMO.RIAL HI-GHW.AY HA U- PPAUGE, NEW YORK 11788 *DATE ISSUED:.:*. 6/1/94 No. 23426-H M SUFFOLK COUNTY 6 -H Imp 12ie To vem en t Con tra ctor License to '- JOE GENTILE —This is cerffythat. P C I SERVICES INC .179 avmg hinished'ili.ei requirements.set fbith-in accordance with and subject to die provisions of applicable laws, ru Siiffolk, State of New York is hereby licensed to conduct business as a lei.afid regulations*6f the County of HOME EvIPRO-VEM-ENT CONTRACTOR, in the County of Suffolk. Additional Businesses NOT'VALID WITHOUT -DEPARTMENTAL.. "SE�kL AND A:'. -CURRENT CONSUMER AFFAIRS]--D*CARD. Director _J �141W_60 11 0 Owl In n, � ,,I �,MUM Y I APP OVED AS NOTED DATE: ' FEE: BY: _ NOTIFY BUILDING Di '.ARTMENT AT 765-1802 8 AM TO 4 'M FOR THE FOLLOWING INSPEC-';?NS: 1. FOUNDATION - TIC PEOUIRED OR POURED C`Ai✓RETE _ 6" JAMB THICKNESS 2. ROUGH - FRAMI,^JG & PLUMBING TO EXTERIOR DOOR 3. INSULATION E ANDREW 4. FINAL - CONSTRUCTION MUST V. BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE GIAMBERTONE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. & ASSOCIATES Ld ®ARCHITECTS — — — — — — — I COMPLY WITH ALL COD 'OF 62 Elm Street NEW YORK STATE &: TOWN ODES S REQUIRED AND CO" DlTi NS OF Huntington, NY 11743 STEEL CELLAR R I i sou77 : , t - oAM Telephone: 631.367.0050 EXISTING D15HWA5HING ENTRANCE I I p EX. I I EXISTING DINING ROOM u1�IG�u 'rv' 1 ' =s Fax: 631.367.6636 FP 'V--4" G.H. ,A ~ I EX. 01-ATI H \ e u J EXISTING _ _ _ r- I - I GiambertoneArchitects.com SKYLIGHTS-VENT ,'I I I ❑ �X� i EXISTING I I I I 2a'-43/4" OCCUPANCY O II ,©. VESTIBULE I� _ _ _ _ �I I USE I S U N LAW �. i I .. - w....w................................._w.__. . .... ... _..�............_.w. . w.. ,......... WITHOUT CERTIFI OF OCCUPANCYEl f , EX. (2) 2X12 HDR(V.I.F) 57225 Main TRIMMED OPENING I TRIMMED OPENIN6 ELECTRICAL - - - - - - - - 13.0.51 B.O.8I 1 H. INSPECTION REQUIRED - Road LLC EX. (2) 2XI2 HDR 2'-1Oy v. =J - - - - - - - - - - - - - - - ��IiIIIIIIII-�\IIItIIIIIIII ��II IIIIIIIIIIIII IIIIIIIIIIII��SZlx�°+fl IIIIII1IIIIIIIIIIIIIIIIIIII18"4 G8IIIIiIIIIIIIIIII'-2IIIItIIIIIIIIIII" G.H. \IIIIIIIIIIII IIIIIIIIIIIII IIII F.P. o IIIIII IIIIII I(IIIIIIIIIIIIIIIIIIIIII IIIIIII -=t'-o° iIIIIIIIIII iIIIIIIIIIIIIIIII IIItIIIIIIIlIIIIII ►°-- IIIIIIIIIIIIIIIII ItIIIIIIIIIIIIIII 13' \\IIIIIIIII1IIIIII I IIII/IIIIII1IIIIII / —IIIIIIIIIIIIIIIIII�IIIIIIIIIIIIIIIII ubzFIiII lzo AGR.—H. -- - ---II t----4-----" H-- _ q -----„ � /-�—�---- - - EXI5TING A IMSP EQTIOV GO D - - — — — = — — — — — \ REQUIRED BEFORE - — — — — — — — — — — — — PORCH 'I-8" B.O.BEAM HT. OPENING ........_...w..m....._...__.......-.....:. .-H.�..._...-s...,..._...._..f..,__.....,,...._�t._?....=....-.1'....�:. ...-,..._..5.._...a....e._'=.. ......_.._...y........Southold, outhold,.....!..v .r_...C.._.l,......N....N_...y.. .. a.._.. ..w��.....:..oT�.. ' ..�..�.mQ..n.....Y EXISTING - - - - - - - - - - - - - - - _ ... �p....w. ..� ...... .� ... ..�. ....m..._............._....m.................. - - - - - - - - - - - -KITCHEN 20'--V2"_ _ _ _ _ _ _ _ _ _ _ _ - - -- 19-012_ _ _ - --EXISTING ......................... _ ..._..__.......,..... ...M. '..u. .._..._.. .................. ...... .. _ ... ........ ..... .. ...._. .5KYLISHT5 . X EXISTING2019-12-02 Issued for Permit13ANGUET TABLE X ............................... ............................... ............................................ El " IL - - - - - - - - - EXISTING HALL ...__.-----................ PLUMBING WALL ....... FFI 7 „ H -0EX. GL. EXISTING WALK-IN REF. . ... FLOOR TO FLOOR 6° JAMTHICKNESS EXISTING 8-4" (ASSUMED 6" EEX. 6ATO THE DOOR JOISTS)BATHROOM BATHROOM FF EpAVALVE EXISTING LOBBY -1'-7 G.H. 60TGzq. V U I 11JAHIGKNE55 PLUS METAL BUCK 20130' FN T � Issue.............d For Permit , ...... EXI5TINOI OMM0� ROOM. © 2019VGA T- I THE COPYRIGHT DRAWINGS,SPECIFICATIONS, AND OTHER DOCUMENTS PREPARED BY ANDREW V.GIAMBERTONEAND ASSOCIATES,ARCHITECTS,P.C. (AVGA)FOR THIS PROJECT,ARE INSTRUMENTS OF AVGA. THESE DOCUMENTS SERVICESARE SOLELY E UNLESS OTHERWISPROVIDED, AVGA SHALL E DEEMED THE AUTHOR OF THESE DOCUMENTS AND SHALL RETAIN ALL COMMONLAW,STATUTORY AND OTHER RESERVED RIGHTS THAT THESE DOCUMENTS SHALL NOT BE USED BY THE OWNER, OR OTHERS, ON OTHER PROJECTS FOR ADDITIONS TO THIS PROJECT, OR FOR THE COMPLETION OF THIS PROJECT FOR OTHERS. Plotted: Monday,December 02,2019-8:10am By: dennis 1 1 File: L:\AVGA CurentJobs\North Fork Table 19-012\Design Development\A2; ; g ...........EXISTING ExistingConditions Existing Floor Plan -011 : 1/4 1/4" = 1-0" H`; DMR 2 I I i i I 2 t 451 DEMOLITION NOTES: I. CONTRACTOR TO BECOME FAMILIAR WITH THE EXISTING STRUCTURE OF THE HOUSE, LOCATING BEARING WALLS AND HEADERS. 2. CONTRACTOR TO VERIFY EXI5TIN6 CONDITIONS AND ASSUMED STRUCTURAL CONDITIONS. NOTIFY ARCHITECT IMMEDIATELY IF FIELDt! CONDITIONS DIFFER FROM CONSTRUCTION ORAWING5. 3. CONTRACTOR TO PROVIDE TEMPORARY BRACING, AS REQUIRED TO PROTECT THE STRUCTURE DURING THE ALTERATION AND CONSTRUCTION PERIOD. k 4. CONTRACTOR TO REVIEW AREAS FOR P05SIBLE 516N5 OF MOLD, IDENTIFY THEM AND PROVIDE REMEDIATION. 5 CONTRACTOR TO INSPECT EXISTING WALL 4 CEILING FINISHES AT ALL LOCATIONS WHERE THEY NOTED AS BEING MAINTAINED AND ADVISE ARCHITECT OF ANY REQUIRED REPAIR5, PRIOR TO BID-. CONTRACTOR TO REFER TO A5BE5T05 5URVEY AND IDENTIFY ASBESTOS LOCATIONS. REMEDIATION AND REMOVAL AS REQUIRED BY LAW. b. CONTRACTOR TO INSPECT Q REVIEW EXISTING AND NEWLY EXPOSED FRAMING STRUCTURE AND TO IMMEDIATELY NOTIFY THE ANDREW V ARCHITECT OF ANY CONDITIONS THAT VARY FROM TH05E ASSUMED HERE-IN, AND OF ANY DAMAGE OR OMPROM15E5 TO STRUCTURAL AND FRAMING MEMBERS, WHETHER FROM WATER DAMAGE, INSECTS, PREVIOUS CONSTRUCTION OR ANY OTHER MEANS. 7. WHERE NOTED FOR EXISTING WOOD FINISHED FLOORING TO REMAIN. REPAIR ANY DAMAGED FLOORING AND APPLY NEW FLOOR GIAMBERTONE FINISH TO MATCH EXI5TIN6. & ASSOCIATES 8. PROVIDE PROTECTION FOR ALL EXIST'G TO REMAIN 9. CONTRACTOR TO VERIFY CAPACITY 4 LOCATIONS OF EXISTING HVAC SYSTEM AND TO REVIEW RECOMMENDED MODIFICATIONS, AND/OR UPGRADE5 TO EXI5TIN6 SYSTEM, A5 REQUIRED W►TH ARCHITECT PRIOR TO BID. CONTRACTOR TO REMOVE EXISTING RADIATORS AND PIPING, GAPPING OFF PIPING AS REQUIRED AT AFFECTED AREAS, UNLESS OTHERWISE NOTED. ®ARCHITECTS 10. ALL ELECTRICAL LINES TO BE REMOVED OR GAPPED IN WALLS TO BE REMOVED (VIF). CONTRACTOR TO PROVIDE NEW OUTLETS AND CONTRACTOR�TO PROVIDE NEW LIGHU&HOUT THE HOUSE r1TIING AS SHOWN ON THE PD IN THE NEA KALLS AS LANS AND To REPLACE EXISTIR ALL PERTINENT CODES NG FIXTURES AS PER OWNERCATIONS NOTED ON AALL WORK 62 Elm Street TO BE IN ACCORDANCE TO LATEST BUILDING AND ELECTRICAL CODE REQUIREMENTS. �— REMOVE 11. ALL DEMOLITION DEBRIS SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A SAFE, LE6AL MANNER. JOB 51TE SHALL BE Huntington, NY 11743 REMOVE _/) I I EXISTING P SOFFIT FREE OF ACCUMULATED DEBRIS. A REFUSE PUM5TER OF APPROPRIATE 51ZE SHALL BE MADE ACCESSIBLE ON THE SITE DURING EXISTING WALL I I I CONSTRUCTION PERIOD AND SHALL BE EMPTIED ON A WEEKLY BASIS. CONSTRUCTION 51TE SHALL BE BROOM SWEPT ON A NIGHTLY Telephone: 631.367.0050 1 — — — — — — — BASIS. 14. COMPLETION OF JOB, 51TE 15 TO BE CLEARED OF EXCESS DEBRIS AND MATERIALS. JOB5ITE TO BE BROOM SWEPT AND GLEAN OF Fax: 631.367.6636 DUST AND DEBRIS. ALL WINDOWS TO BE GLEANED IN51DE AND OUT. THI5 15 TO BE DONE TO SATISFACTION OF THE ARCHITECT AND OWNER PRIOR TO RECEIVING FINAL PAYMENT. _• GiambertoneArchitects.com i EXISTING DISHWA5HING /�� ���/�Q�� Ex I I EXISTING DINING ROOM � II'!O WORK) FP I I I7EMOL I TI ON LEGEND: ........................ .................... 61 , REMOVE J CONTRACTOR TO REMOVE ALL WALLS,PARTITIONS OR PORTIONS THERE-OF EXISTIN6 SOFFIT I I 5HOWN THUS. ALL EXISTING PLUMBING AND ELECTRICAL LINES TO BE CONTAINED ''✓ _` THERE-IN ARE TO BE GAPPED BELOW FLOOR LEVEL. CONTRACTOR TO PROVIDE EXISTING I I REMOVE TEMPORARY BRACING AND/OR SHORING AS REQUIED TO SUPPORT REMAINING VESTIBULE I I EXISTING P05T EXISTING STRUCTURE AND PROTECT SAME DURING PERIOD OF CONSTRUCTION. 57225 Main I (NO WORK) I I TEMPORARY BRACING AND/OR SHORING SHALL REMAIN IN PLACE UNTIL ALL OF { THE NEW STRUCTURE HAS BEEN COMPLETED. Road LLC EX15TINS WALL5 AND CEILING5 TO REMAIN - CONTRACTOR TO PATCH/MATCH a REPAIR ANY DAMAGE CAUSED BY DEMOLITION AS REQUIRED I - - - _ _ _ __ _____= NOTES: Southold, NY E I I I DRAWINGS ARE NOT TO BE SCALED. ..................._._ _ w. _ _._u _............. _ . EXISTING WRITTEN DIMEN51ONS SHALL ALWAYS REMOVE TAKE PRECEDENCE.COVERED WALL 19-012 EXISTING WALT. I PORGH .................... ....._.................................................... `J `........ .< .k ._._.................................. ............. ...... ...i EXISTING I I I I , KITCHEN I L — — -J �ii I I 201.9-12-02 Issued for Permit (No WORK) I I I I I I �I I I I .......................................... ....................... .....................................................................__.................................. . EXISTING BANQUET TABLE I I I I _._.......,.....w...... ..... w ....W..... ..w..... .__._............. El ...� ._.,_............- II II I F I EXISTING BAR MO WORK) \ EXISTING HALL f 4 (NO WORK) I ( (<m.._.. ._.... ... .,. .....w_....... ........_M..._ .. _ ... ,_. _. I I - - - 1 EXISTING ED EX. GL. I RED AR WALK-IN REF. I `5\�pENT (NO WORK) EXI5TING EXISTING BATHROOM BATHROOM I \ EXISTING LOBBYz° (NO WORK) NO WORK) I \ / \ (NO WORK) a- uO \/ sTgTF 2080 1 OF NES II II II II II II II II II II II II II II II II II II II II II II II II I I I I I I I I I I I I I I I I I I I I I Issued For Permit , II II II II II II I � II II II II II ............ 0 2019 AVGA : ............................................................_............I._.........._................... .... ....................... I I THE COPYRIGHT DRAWINGS,SPECIFICATIONS, AND OTHER DOCUMENTS I I I I I I I I I I I I I PREPARED BY ANDREW V.GIAMBERTONE AND ASSOCIATES,ARCHITECTS,P.C. (AVGA)FOR THIS PROJECT,ARE INSTRUMENTS OF AVGA. THESE DOCUMENTS ARE SERVICES FOR T HE USE SOLELY WITH RESPECT TO THIS PROJECT.UNLESS I I I I I I I I I I I I I OTHERWISE PROVIDED, AVGA SHALL BE DEEMED THE AUTHOR OF THESE EXISTIN GOMMO ROOM. DOCUMENTS AND SHALL RETAIN ALL COMMONLAW,STATUTORY AND OTHER I I I I I I I I I I RESERVED RIGHTS THAT THESE DOCUMENTS SHALL NOT BE USED BY THE Io(N I I I I OWNER, OR OTHERS, ON OTHER PROJECIS FOR ADDITIONS TO THIS I I I I I I I I PROJECT, OR FOR THE COMPLETION OF THIS PROJECT FOR OTHERS. II II II II II II II II II II II II I I I I I I I I I I i t I I I I I I I I __....._._...._....... ..._._...._._....... .. .............._ ._.,.,...........w ............ Plotted: II II II II II it II II II II cember 02,2019-8:1 lain BT. dennis File:eL:\AVGA Current Jobs\North Fork Table 19-012\Design Development\A2 vg II II II II II II I � II II II II II II II II II II II II II II II II II II II II II II II II II II II II II I I I I I I I I I I I I I I I I I I I I _ . _ ............. .........,..4..w ZAI lie . . m EXISTING Demolition F.P. Floor Plan -off : Demolition Floor Plan : : ° DMR SCALE : 1/4" = 1'-0" D1 f i �E€E E[ i f , VA BUILDING GODS ANALYSIS ZONING: HB 4 P60 MAINTAIN 4 PROTECT EXIST'G WOOD FLOOR5, EXISTING USE TO BE MAINTAINED FIREPLACE EXI5TIN6 BAR A-2 RESTAURANT (ASSEMBLY) EXISTING R-I HOTEL (RESIDENTIAL) EXISTING CONTRACTOR SHALL FIELD VERIFY EXISTING AN D REW VeTYPE OF CONSTRUCTION TO BE MAINTAINED VB. DUCT WORK SUPPLY AND RETURN. COORDINATE EXISTING WITH ARCHITECT EXIT GIAMBERTONE EXISTING EXISTING & ASSOCIATES EXISTING ®ARCHITECTS II IIEl II III III — — — — — — — 62 Elm Street II Huntington, NY 11743 p � Tele hone: 631.367.0050 I I EXISTING DISHWASHING EX I I I I Fax: 631.367.6636 No VqORK) EXISTING DINING ROOM FP N I '�I ► X EXI5TIN6 x l l LI 12 GiambertoneArchitects.com O REMOVE YESTIIBULEEXISTING POST w..w.,......................... ... __vW .-.W..... ..W..-................... . ............. . ... ..............__. No WORK) p 1 ASSUMED I I A55UMED I I A55UMED N ff EXI5TIN6 2X8 F.J.'SZ EXISTING 2X8 F.J.'S S I ( EXISTING 2X8 F.J.'S ®Ib" O.G. I ®Ib" O.G. I I ®1b" O.G. El H553X3X1/4 III 57225 Main / EXISTING I I S I I COLUMN ON EXIST 1 1 I ASSUMED WI2 BELOW 5TIN6 2X10 G. 'S — — — — — — — — H553X3X3/Ib Road LLC - - - - - - - - - JL - - - - - - JL - - - - - - - - - - - COLUMN ®Ib" O.G. - - - - H553X9X3/Ib - - -- - - - - - - - - - - — — — — — — — - - - - - COLUMN WI4 X 22 FLUSH BEAM 114 X 22 FLUSH BEAM CONTRACTOR TO PROVIDE CONTRACTOR TO PATCH EXI5TING TEW AS REQRED ARY TO INSTALL NEW I I MATCH EXISTING MIN. 2 HR EXISLINry TOTING COVERED EXISTING I BEAMS AND POSTS TYP. I I I CONTRACTOR TO VERIFY \ PORCH Southold NY EXI5TINGFTI CONTRACTOR TO PATCH ZI I EXI5TIN6 STEEL BEAM AND KITCHEN I EXISTING FLOORING TO I P05T LOCATION No WORK) I MATCH EXI5TIN6 I I 19-012 I I I ..._......... ..............................................E EXISTING I I I N I BANQUET TABLE ( I I I 1....2019-12-02 Issued for Permit.................................................................... .... .......... II I i ( I EXI5TING BAR El ...._.w.._............ w.....w ............. _... .,_... . ...... ................. I I i No WORK) \ EXISTING HALL I I I __------.......... No WORK) _........ ................ ........................................ I EXISTING \ I EX. GL. I WALK-IN REF. (NO WORK) I / - - - - - - - - - J EXISTING EXISTING BATHROOM BATHROOM I Y.m , __._.., m _.....^. ..w�..w.,... ..... , (NO WORK) (NO WORK) (NO I';DF� TING LOBBY �F;EB ARCyi GENT w I I I I 2 EXISTING I I I I I I I I I I I I I I I I I I I I I I I I sT 02084 .� 9r/"-OF NeN II II II II II II II II II II II II 1 1 I I 1 1 I I I I 1 1 1 1 I I I I I I I I 1 1 EXI5TIN6 SEATIN6 TO REMAIN WE ARE NOT Mw..,.......... , , . ... ... ._._....... __ ....._.. ... ............... m I I I I I I I I I I I I I I I I I I I I I ADDIN6 OR REDUGIN6 ANY SEATS. I I I I I I I I I I I I I NO CHANGE I II II I II II III III II II II II I II II II II II II II II II II II Issued Fo.... Permit.. ........... ................. ....... I I EXI5TIN(GI GOMMO ROOM. 1 1 I I I I I I I •k_ Y.z'Rxas. © 2019 AVGA I I I I I ANO "�O `: I 1 1 I I I I 1 1 1 1 1 1 1 1 I I I I I I I I THE COPYRIGHT DRAWINGS,SPECIFICATIONS, AND OTHER DOCUMENTS PREPARED BY ANDREW V.GIAMBERTONE AND ASSOCIATES,ARCHITECTS,P.C. I I 1 1 I I I I I I I I I I I I 1 1 I I I I I E (AVGA)FOR THIS PROJECT,ARE INSTRUMENTS OF AVGA. THESE DOCUMENTS ARE SERVICES FOR T HE USE SOLELY WITH RESPECT TO THIS PROJECT.UNLESS I 1 1 I I I I I I I I I I I I 1 1 I I 1 1 1 1 OTHERWISE PROVIDED, AVGA SHALL BE DEEMED THE AUTHOR OF THESE II II II II II II II II II II II II DOCUMENTS AND SHALL RETAIN ALL COMMONLAW,STATUTORY AND OTHER RESERVED RIGHTS THAT THESE DOCUMENTS SHALL NOT BE USED BY THE i j OWNER, OR OTHERS, ON OTHER PROJECTS FOR ADDITIONS TO THIS I I 1 1 I I 1 1 I I I I 1 1 1 1 1 1 I I I I 1 1 I PROJECT, OR FOR THE COMPLETION OF THIS PROJECT FOR OTHERS. i I EXIT 1 1 I I I I I I I I 1 1 I I I I I I Plotted: Monday,December 02,2019-8:12am By: dennis I I I I I I I EXISTING I I I € File: L:\AVGA Current Jobs\North Fork Table 19-012\Design Development\A2. g EXI5TIN6 EXISTING F'P' EXI5TIN6 EXISTING ............ ....... . .........................._..... _..... ..........._..... k EXISTING Proposed Proposed Floor Plan I Floor Plan 1/411 SCALE: 1/4" = V-0" = 1 -0 E °: y: A, DMR E I {f 4 I cl 5D NOTE: FLOOR PLANS OBTAINED FROM NOTE: FLOOR PLANS OBTAINED FROM DRAWINGS PRODUCED BY SAM TELL DRAWINGS PRODUCED BY SAM TELL COMPANIES DATED JANUARY 9, 2020. COMPANIES DATED JANUARY 9, 2020. xtxY rn:cs ea+ns 500W JTA10 AREAS THAT NEED elxlcac A HAND SINK s 1 neuro CLIENT gE T RIY SOLUTIONS O 4 0O ^ _ P.W. GROSSER CONSULTING ENGINEER 15'SETBACKS iMCA PtAi „ NeT W AND HYDROGEOLOGIST, P.C. 7vlxs;ua xa$W t iEMiff a POfif' Ti97 .....,,�, 1 .s. XbS VWR g�VIA,„A 4'01A. 630 634 Johnson Avenue.. Suite 7 Bohemia. NY. 11716-2618 ---of Phone:(631)589-6353. Fax:(631)589-8705 _,•� I E-mail: fNFO@PWGR4SSER,GQM r 32 3 sEs" ; i 0 s -.• I , 4-y» r � $)W caaM ON �cHarWADE/ 171 CONSULTANTS \ YU STORAM 54 31 AEo { . a„u ,';,'. 15 I i 9LiB ON bR/WP b-4.� �t-�• ! kKf$TV*°�� FIS tib.HST EX POST T f: BAG-IN-BOX ins axb Pu I 'yam•; ':.r j..w,re' S C�aD �_ b Dc.K sits.MW 41 <�RtCtc 28 "••s f i :".I!, {:'.g»,, ".„g.., �• ECA”0�vmt�Lir J/ �i� gym' hr 445' I; C2" �1. :w• ✓ y r.7.. MINARINb ON SU 8'-0'MAX PXIST SPAN rap VEArr • of R1 . ..,': r ti "'•�I • , :,�.;:. ,= 373. 5R �•�^� y--��;� .z.;iL. $W9lRdBRAJE fARM4.9F'ACZ j pdi2 I O -•�o tt r t } � Mitt • 0941 '.rt ..0 4 w.r PIT 17-5' OT WATER HEATER E EY"rrad� OVA NOW t rq, EE E} 1312 ..Ess F1 Bis 1314. ��f5,t s6tdK i., } nE>; E91 4?2� 61 C•..1 _E;2.i Aqp CLactf9Lt'Y'fvd k Sona Clans hG'did" SYST at sa4.az 5t ,a.�rarr 1,4 491MLAO.`tI FED l 1 2020 FIRST FLOOR PLAN SCALE: NOT TO SCALE EXISTING CELLAR PLAN SCALE: NOT TO SCALE 6 5 4 3 2 1 Number Rovision Descdptwn Revision Date V.T.R. Dedgned By Date Submitted BAG Dr�xn By Date Created J4TA 1/17/2020 Approved By Scale BAG" AS NOTED Client ANDREW V. GIA BERTONE & ASSOCIATES 62 EL STREET " 61 '7 HUNTINGTON, NEVA YORK 1'1743 pra�� WORK4TABLE " �1 �4 14 0 13 " " 1t 22 „ 23 " 25 26 " B5 26 "� "0 B8 DISHTABLE W/ SINK AND (3) SINKS HAND SINK TABLE TABLE TABLE IMC/TEDDY TABLE W HAND DIPPERWELL W/HAND W/HAND TABLE DISHTABL MOP SINK HAND LAV. LAV. UNDERBARTABLE AN"U'611NN W/SINK SINK BOWL- SINK SINK W/SINK W/SINK SINK W.C. W.C• HANDSINK UNDER— UNDER— DISHWASHER COUNTER COUNTER LDISHWASHER DISHWASHER 1 1/ Z' 1/2" 1/2': 1/2" 1/2" 1/2" 1/2': 1/2': 1 i/ llv : 1/2': 1 1/2- 1 1/21' 1 1/2" 1 1/2" project fuidress: 57225 PAIN ROAD SOUTHOLD, TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK 11971 County T ax Map Number: Conb'act Number: " PlPE C'01 4" KITCHEN LINE }�" PIPE Regulat:xyReferenceNumber: �/ GREASE TRAP TO LEACHENG POOLS T;teatdkawng: SEPTIC TANK C.O. 4" SANITARY LINP R 0 U E RISERI DIAGRAM j4 a PLUMBER RISER DIAGRAM Drawing Number: SCALE: N.T.S. NOTE: 1. BATHROOM DOORS ARE TO BE SELF CLOSING. 2. ALL FOOD ITEMS ARE IN BULK AND WILL BE TRANSPORTED IN COVERED FOOD CARRIERS. y „> 3. ALL SINKS SHALL BE EQUIPPED WITH SPLASH GUARDS. ` 4. g . „ 8 Sheet of $ Q� 6'"NGC project Number: w unauthorized alteration or addition r Io this drawing and related documents AVG 19 ate is a violation of Sectbn 7249 U c of the New York State Education Law O o General Notes001 � L THE CONTRACTOR SHALL CARRY WORKER'S COMPENSATION AND GENERAL LIABILITY INSURANCE OR A5 REQUIRED 8Y THE GOVERNING MUNICIPALITY. 2.ALL MATERIALS,ASSEMBLIES,AND METHODS OF CONSTRUCTION INCLUDING BUT NOT =r LIMITED TO FORM-WORK,BLOCK,FRAMING,NAILING. PL.ACIN6 OF CONCRETE,ETC. ARE TO BE CAREFULLY SUPERVISED BY THE CONTRACTOR TO BE SURE THAT THEY ARE IN ACCORDANCE r' WITH THE DRAWINGS,SPEGIFIGATICNS,APPLICABLE GORES AND&OOD PRACTICE. 7 LAVATORY AND FAUCET" TO COMPLY W/ 101r, 3.ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODES AND ORDINANCES. A111.1-09 AGGE551$L.E BA MA M GRAB P ICC PLUMBING FACILITIES 4.ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH GOOD BUILDING PRACTICES. All .1- REQUIREMENTS 5.THE PREMISES SHALL BE KEPT GLEAN AT ALL TIMES AACH DAY AT COMPLETION OF € t MIN. B'-0" WORK,THE CONTRACTOR SHALL REMOVE ALL WASTE MATERIALS,TOOLS,RUBBISH, ETC., ��#^ LAY AND FAUCETS TO 3' 4" CLEAR COMPLY W/ ICG/ANSI GLEAN ALL&LASS AND LEAVE WORK BROOM GLEAN UNLESS OTHERWISE SPECIFIED. a '18" ¢ CHAPTER 6 HANDICAP b.ALL DIMENSIONS AND CONDITIONS ARE TO BE FIELD VERIFIED. THE CONTRACTOR SHALL ! MIN. 3 RETIREMENTS NOTIFY T1 ARCHITECT OF ANY DISCREPANCIES IN WRITING BEFORE PROCEEDING W1TH THE ANDREW V. MIN. I'-O" WORK EFFECTED BY SAME. MAX. 9.DRAWIN65 ARE NOT TO BE SCALED;ARiTTEN DIMENSIONS SHALL ALWAYS TAKE -� 21. GIAMBE"P TONE �. MIN. MIN. I TOILET PAPER 8.LARGE SCALE DETAILS ARE INTENDED TO CLARIFY INFORMATION AND THEREFORE SHOULD BE EXAMINED THOROUGHLY PRIOR TO PROGEEDIN6 WITH THE WORK A5 THEY TAKE x z PRECEDENT OVER SMALLER SCALE DRAWINGS. & ASSO CIATES m m m is 9.ALL WORK SHALL BE PERFORMED AS OUTLINED IN THE AIA DOCUMENT 2 I ,B O GENERAL CONDITIONS. � ®ARCHITECTS 10. OSHA RULES AND REGULATIONS FOR SAFETY SHALL BE IN EFFECT AT ALL TIMES DURING f THE COURSE OF THE PROJECT. ALUMINUM GRAB BAR AS MIN Ii. ALL WORK SHALL BE PERFORMED IN SUCH A MANNER AS TO HAVE SAID WORK BE FREE 62 Elm Street A.C.TO COMPLY Yv. HANDICAP REQUIREMENTS MIN DEPTH , NY 11743 ICG/ANSI CHAPTER b PER ICG/ANSI CHAPTER b i'1 OF DEFECTS. 12.CONTRACTORS SHALL REVIEW ALL SHOP PRAWIN66 PROVIDED BY 50 CONTRACTOR FOR i Huntington 1 Typical Accessible Toilet Room Elevations COMPLIANCE TO THE CONSTRUCTION DOCUMENTS AND THEN SUBMIT SAID APPROVED DRAWIN65 TO THE ARCHITECT FOR APPROVAL. Telephone: 631.367.0050 GN 1.1 SCALE: 1/2 - 11-01113.NO 505TITU11ONS SHALL BE MADE EITHER DURING BIDDING OR CONSTRUCTION WITHOUT Fax: 631.367.6636 WRITTEN APPROVAL BY THE ARCHITECT. SUBMIT ALL INFORMATION NECESSARY TO EVALUATE SAID PRODUCT OR SYSTEM AGAINST THAT SPECIFIED PRIOR TO INCLUDING SAME IN EITHER THE BILL OR "TFC woRK" GiambertoneArchitects.com l - $ -/- 14.ALL DRAWIN&5 PROVIDED FOR THI5 PROJECT BY THE ARCHITECT SHALL BE RETURNED UPON COMPLETION OF THE WORK. 001 1qg�- -/-- ` 15.ALL COUNTER AND WORK SPACES SHALL BE ICG/ANSI COMPLIANT. --�----•-- �! -�- INTERIOR ALTERATION AT FIRST FLOOR - SITE DATA do pro)ect: -- -- ; ♦ �District(Town of Smthhold -ZonMg Code) DRAWING LIST: ' -- �\ \ Tax Map#: Dist. 1000-Sec.65-B1k.03-Lot 215 fp 57225 Main 146 - ` LOT SIZE: 20,000 s.f. 49p49.16 s.f. General Buildin Code Data € --,/ -- ----' ; ` a LOT WIDTH: 60.00' 210.90' \ , LOT DEPTH: 100.00' 26968' t 400000, --' � � � FRONT YARD: 15.00, 21.40, GN1.1 General Notes Road LLC 10.00' lOs9' #122AI' EX1 Existing Floor Plan EXISTING PROPOSED TOTAL FLOORIcd,00,000 50TH SIDE YARDS: 25.00' 152b0' I REAR YARD: 25.00' 18"f 95' D 1 Demolition Plan FLOOR AREA: FLOOR AREA: AREA: USE AND OCCUPANCY ; FIRST FLOOR 5,193.48 S.F. 0 S.F. 3,193.48 S.F. A-2 A55E1�LYlR-I RESIDENTIAL I 1 --'' i LOT GOVEi2AGE: 4056 235356 € € Al Existing Cellar SMOND FLOOR 1,38929 S.F. O S.F. 1,38929 S.F. RI RESIDENTIAL GROUP'(HOTEL) Southold NY -- ---- `� ♦ BUILDING HEIGHT: 55' 50' THIRD FLOOR 120,69 S.F. O S.F. 1,220.69 S.F. RI RESIDENTIAL GROUP'(HOTEL) w �_ ---,- / A2 Proposed First Floor Plan s ° .,6 S.F. O S.F. 5803.46 S.F. i ---- \ NUMBER of STORIES: 2 5 A3 Proposed Reflected Ceiling Plan ���� ����i��.�, p g ALLOWABLE AREA(TABLE 506.Z: A4 Proposed Fire Alarm A-2 FOR NON-5PRINFLERED,Vb CONSTRUCTION : 6,000 S.F. 19-012 p ..._.....-.... _.__ _w _ __.____.____-._ __...__ ._____.. __._..._.._.._......_._ its EXISTING P1 Proposed Slab-Plumbing-Floor Drain R-I FOR NON-SPRINFLERED,W CONSTRUCTION : TpOo S.F. Cs COVERED ENCLOSURE \ g 2020-02-10 Issuedfor AmendmentWO �jo� \ , REQUIRED SEPARATION OF - 1 �yG A-2 AND R I 2hr FIRE SEPARATION REQUIRED 2020-02-27 Revised for Bld De t comments � ' 1`�1' ` ♦ OCCUPANCIES(TABLE�°�8.4) I g p #OF SEATS EXISTING 64 PROPOSED 64 I TYPE OF CONSTRUCTION(TABLE 601): 5b-EXISTING I I Code Plan Legend THE SUPPORTING CONSTRUCTION SHALL DE 1/ i • SUPPORTING CONSTRUCTION(SECTION ♦ � � �� \ ♦ 2-HouR�€Re RATED 9ARRICR®®®®®® >JaT PROTEGTEDTD AFFORD THE REQUIRED \ EXIT 911.25) FIRE-RESISTRICTIVE RATING OF THE HORIIZONTAL "� �• +\ ` 2-HOI R FIRE RATED C LINO A65EMMBLY SUPPORTED.2 HR RATED. 1 ; ; TRAVEL DISTANCE&---050� ASSEMBLY 000UPANGY A-2 ("�"9 : . � „, INTERIOR WALL AND CEILING FINISH € HOTEL 1 REQUIREMENTS BY OGGUPANGY(TABLE 0"VI INTERNALLY ILLUMINATED MASSEML803.11 ) 6600 0530 RE3 Y OCCUPANCY R-1 �� O INS CME T€4 N to€� r -- GROUP GORR,DORS p�tGL05ED SPACES EXI SIGN TO COMPLY WITH NY STATE .... , ROOMS AND V�- e J A-2 B G 1 i GRAVEL \ ♦ PLUMBER CERTIFIG�1 TION; -- -------- — ON LEAD CONTENT B♦-FORt~, ,,--'- ( l j_ i j i GLA55 B INDEX 26-95;SMOKE DEVELOPED INDEX 0-450 CERTIFICATE OF OCC °ANC y CLASS G FLAME SPREAD INDEX 96-200;SMOKE DEVELOPED INDEX 0-450 Cyl� SOLDER USED IN WA;ER \\o I?_ SUPPLY SYSTEM CAN1 iO€XIStIN& r-' ) " `� ! PROVIDE ONE HAND-HELD PORTABLE 2-A CLA55 `� ♦�o i PORTABLE FIRE EXTINGUISHERS(SECTION 406) FIRE EXTIN6UISHER ON EACH FLOOR OF BUILDING. ► EXCEED 2110 OF 1% LA`'16/INYL�SHED RISME I = � ♦ o ---�--- EXTINGUISHER,AND WITHIN 30'OF THE COMMERCIAL �i �.\3'� P �� �o �'— -_-j i`--� ( ' I KITCHEN,TO BE INSTALLED ON HANGER OR BRACKET y s SUPPLIED.EXTINGUISHER TO BE LOCATED IN A \ 5 \ ♦ I CONSPICUOUS LOCATION,UNOBSTRUCTED AND UNOBSCURED. EXIT - - - - - - - - - - - - 7 T-9 O 1 \ I , ? S 42084 1 TFOFNEw ., f `4�LUMB�NG ♦ � ` � MAXIMUM OCCUPANCY OF A-2 MAXIMuiM 64 OCCUPANTS AS EXISTIN O 1 RESTAURANT(SECTION 1004.12) PREVIOUSLY APPROVED BY THE A[L-PLOrABING WASTE WALK-I \ BUILDING OFFICIAL \ I WATER LINES NEED•:'. .:,: I► , L _ ,� IRE & E COV ♦ + ` —_ I 2-HOUR FIRE RATED j!; I T5STtt G,�EFOR , I CEILING-SEE DETAIL WIDTH A MEANS OF EGRESS FOR Issued For Permit �� •ro ! I u STAIRWAYS SHALL BE NOT LESS THAN 03X64 = IQZ° _ __..........__... �..._... ._......�.-........._ _-..._...._._._.....____...._._.___.._._._....__ ASPHALT \\\ ♦ �o I I I (SECTIONS 1005.3.1) BUT NO LESS THAN 36" IN WIDTH t \ I .y 1 I 1 I �,opyrig © 2020 AVGA ASPHALT I — ass] I I }- , --, WIDTH OF M.�1N5 OF EGRESS OTHER 02 X EJ4 = 12,150 THE COPYRIGHT DRAWIlVGS,SPECIFICATIONS, AND OTHER DOCUMENTS kqq�— I THAN STAIRWAYS SHALL BE NOT LESS Y u PREPARED BY ANDREW V.GUWERTONE AND ASSOCIATES,ARCHITECTS,P.C. 110' �e EXISTING EGRESS METAL ( —1 n °' BUT NO LESS THAN 56 IN WIDTH AVG FORTHISPRO ECT,ARE INSTRUMENTS OF AVGA THESE DOC[JMENCS • 1 : I I THAN(SECTIONS 10055.2) i . ( ] STAIRS FROM 3RD FLOOR ♦ + Q I I 1 ARE SERVICES FOR T HE USE SOLELY WITH RESPECT TO THIS PROJECT.UNLESS SSP ` ' • -' ---- - - --_- -' ; DOCUMENTS AND SHALL RETAIN ALLCOMMONLAW,STATUTORY AND OTHER OTHERWISE PROVIDED, AVGA SHALL BE DEEMED THE AUTHOR OF THESE l— —�� I - - --- ---- I RESERVED RIGHTS THAT THESE DOCUMENTS SHALL NOT BE USED BY THE �aav c�.l�Q:na �: Proposed Interco = - - -- r /'' ��- ' -���7�� "'-'-:�— ;' SPACES WITH ONE EXIT(SECTION 1006.2.1 OWNER OR OTMAS ON OTHER PRO M FOR ADDITIONS TO THIS PROJECT, OR FOR THE COMPLETION of THIS PROJECT FOR OTHERS. j T EXISTING WOOD /. I. aFe ■ �€.la Ie e€Ie e'er MAXIMUM OCCUPANT MAXIMUM TRAVEL � 2020 J J Reno n of STOOP i �- I �e x 3, K'<'; '. i GROUP LOAD OF SPACE DISTANGI+ Plotted: . P Y I Thursday,Feb 27 2020-2:27 m B dermis s Floor - L_ . . „ . _^ .. it t , ;,.. :; qL : ., ... A-2 4a 95 File: L:\AVGA Cutteat Jobs\North Fork Table 19012\Workiag Drawings\G € xistin Frame i" ` I ' - ` - , R-1 10 NP. / '' MINIMUM NUMBER OF EXITS OR ACCESS TO :. ,:,; _ ` '� �- `_------- , ` :.: . . :; :: EXITS PER 5T0 (TABLE 1006 ) \ - ------------ ----_--- ---, ANT LOADS BETYVEEN 0-500 ' Building I '��- RY 3.1 2 FOR occuP ��:i�, �°°D -- General Notes E .--' 4 /- , � ��---' -- 516N -• €; � SHALL SWING IN DIRECTION OF TRAVEL WHEN 1 '+GRAI/EL EW BL.UESTONE ---' � 3r --I i -1/244OUR FIRE RATED DOORS MINIMUM FLOOR AREA ALLOWANCES SERVING A ROOM OR AREA WITH AN OCCUPANT — — — — — — — 1 PATIO -� ' WO -- — —— — { } PER OCCUPANT(TABLE 1004.1.2) LOAD IN EXCESS OF 50 SIGNNall� STONE / h! '' -''7kGGE551BLE ,.��- j I CLASSIFICATION OF WORK 981' N 1 + • ( EXISTING BUILDING GORE OF NEW I RAMP WITH r/ i ALTERATION LEVEL 2 NO FIRE SPRINKLERS REQUIRED N.T.S. ' HANDRAILS A5 -- YORK SECTION 404) S PER CODE - y, v�dp *00000, Iwo dt, -��-� lam •- ,` \ F 11�'' / € hood S S�h� �� F Site Plan Code Summary- First Floor plans met Cfo-�ertc�r SCALE: 1/8" = P-0" S'� k SCALE: 1:: =20 — I i � d f I y E � f a uY. F 6" JAMB THICKNE55 T°EXTERIOR DOOR � ANDREW Ve f GIAMBERTONE E f " & ASSOCIATES 4LJ ®ARCHITECTS E — — — — — — — ` 62 Elm Street m � Huntington, NY 11743 STEEL B1DOOR GO Telephone: 631.367.0050 ENTRANCE EX I Fax: 631.367.6636 Z F' EXI5TIN6 DINING ROOM EXISTING ,'-4'G.H. GiambertoneArchitects.com dl i SKYLIGHTS-VENT �— — — — �I EX. OLS.2 M EXISTING VESTIBULE — — — — EXISTING 2X8 R. .'S EXISTING 2X6 RK S I 016"O.G. 016" O.G. p.of ' t: / I I 15STEEL 57225 Maino� F 1r TING G. ' — — — — ----\ — — — — Road LLC Gib"OL. - - - - - - - - I �, t — — — — — — — — — —— ——— — — EXISTING -0C.H.G _ _ _ _ _`- � Southold NY "1 8 B.O.BEAM H6T. EXI5TIN6 I ZI I- - - - - - - - - - - - - - -- - �- - job nuinber.* KITCHEN �- - - - - --- - - -- - - II;� I - - - - - - - - - - - - - - -- - -- I - - - - �► > , �Iz ,= - - - - - - - - - - - - - - - - - -- 19— 012 EXISTING —��I� � � ;o I � a' I......................................................................................................................_..................................................................................... 5KYL15HT5 \� // I z I I - - - - - - - - - - - - -- -- - - I Cate: x\ -II _ BANQUEI.I TABLEu-I *� i I — — — — — — — —— — — — — — —— — — 2019-12-02 Issued for Permit N I X I .......2020-02-10 Issued for Amendment....................................................................... — — — — - — M - - - - - - - - - -- - - - - - - - - - - - - - - - __ _ / 61 «r* _ of II I - - - - - - - - - _ El X I L - - -- - -_ ___ ___ __ __ . __._..---- I r ..............................._. .........._.................. .................._........... ........ __.................. .... . �._........ ...._ __ \ EXISTING HALL 8'-2"G.H. PLUMBING WALL r—on I I I S I EXISTING AALK-IN REF. I ►5 N6 " JAIS VI EXISTING EXISTING I EX. 6AS THE DOOR�5 BATHROOM BATHROOM I swrr-of r- / VALVE / EXISTIN6 L0251' D AFRI TEls� I I I I I I a J" JAM��MIGKNESS i t I I I I I I PLUS METIAL BUCK �- cl' �208fl Q� OF NCO II II II II II II II II II II II II \ �; : i.; : - -----�--.-• -- II II II II II II II II Iii II II II II it II IIS II II II II IIS it II II i t I I I I ► I� I I I I I , , , I I I I I I i t Issued For Permit II II II II� II II i ► ► Tim II II II �- GOMMO ROOM_ EXISTING I I I I I I I I I I .€. ty © 2020 AVGA 8'-4 " G. I I I I I I I I I I I I I I I I I I T I I I I I I SPECIFICATIONS, d PREPARED BY ANDREW V.GIAMBBERTONE AND ASSOCIATES,ARARCHITECTS,P.C. (AVGA)FOR THIS PROJECT,ARE INSTRUMENTS OF AVGA. THESE DOCUMENTS ARE SERVICES FOR T HE USE SOLELY WITH RESPECT TO THIS PROJECT.UNLESS OTHERWISE PROVIDED, AVGA SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND SHALL RETAIN ALL COMMONLAW,STATUTORY AND OTHER I I I I I I I I I I i t I I RESERVED RIGHTS THAT THESE DOCUMENTS SHALL NOT BE USED BY THE OWNER, OR OTHERS, ON OTHER PROJECTS FOR ADDITIONS TO THIS I I I I I I I I I I I I I I I I I I I PROJECT, OR FOR THE COMPLETION OF THIS PROJECT FOR OTHERS. II II II II II II II II II II � II II I I I I I I I I I I Plotted: Monday,Febmaty 10,2020-12:19pm By. densis EXISTING Be: L•\AVGA Cartent Jobs\North Fork Table 19-012\Working Drawings\A2! F.P. r.. ......_..--------._......._......_.__..._... _......__.................................................................... f g Existin Conditions _ Existing Floor Plan f Floor Plan SCALE: 1/4" = 1'-0" ' Scale: 1/41' = 11_011 F c: .ravvm: DMR Al (f E DEMOLITION NOTE5: I � ; T:. I. CONTRACTOR TO BEGONE FAMILIAR WITH THE EXISTING STRUCTURE OF THE HOUSE,LOGATixb BEARING WALLS AND HEADERS. , 2. CONTRACTOR TO VERIFY EXISTING CONDITIONS AND ASSUMED STRUCTURAL CONDITIONS. NOTIFY ARCHITECT IMMEDIATELY IF FIELD CONDITIONS DIFFER FROM CONSTRUCTION DRAWIN65. 3. CONTRACTOR TO PROVIDE TEMPORARY BRAGIN6,AS REQUIRED TO PROTECT THE STRUCTURE DURING THE ALTERATION AND CONSTRUCTION PERIOD. 4. CONTRACTOR TO REVIEW AREAS FOR P0551BLE 516N5 OF MOLD, IDENTIFY THEM AND PROVIDE REMEDIATION. 5 CONTRACTOR TO INSPECT EXISTING WALL +E CEILING FINISHES AT ALL LOCATIONS WHERE THEY NOTED AS BEING MAINTAINED AND ADVISE ARCHITECT OF ANY REQUIRED REPAIRS,PRIOR TO BID.CONTRACTOR TO REFER TO ASBESTOS SURVEY AND IDENTIFY ASBESTOS LOCATIONS. REMEDIATION AND REMOVAL AS REQUIRED BY LAW. 6. CONTRACTOR TO INSPECT 4 REVIEWEXISTING AND xEWAND REW LY EXPOSED FRAMING STRUCTURE AND TO IMMEDIATELY NOTIFY THE ; V. ARCHITECT OF ANY CONDITIONS THAT VARY FROM THOSE ASSUMED HERE-IN,AND OF ANY DAMAGE OR COMPROMISES TO STRUCTURAL AND FRAMING MEMBERS,WHETHER FROM WATER DAMAGE, INSECTS, PREVIOUS CONSTRUCTION OR ANY OTHER MEANS. 1. WHERE NOTED FOR EXISTING WOOD FINISHED FLOORING TO REMAIN. REPAIR ANY DAMAGED FLOORING AND APPLY NEW FLOOR GLAMBE1D\."'v0NE FINISH TO MATCH EXI51IN6. I 6. PROVIDE PROTECTION FOR ALL EXISTS TO REMAIN � & ASSO CI VVT Q. CONTRACTOR TO VERIFY CAPACITY d LOCATIONS1ST F O EX INC HVAC SYSTEM AND TO REVIEW RECOMMENDED MODIFICATIONS, ` AND/OR UPGRADES TO EXI5TIN6 SYSTEM,AS REQUIRED WITH ARCHITECT PRIOR TO BID. CONTRACTOR TO REMOVE EXISTING I RADIATORS AND PIPING,GAPPING OFF PIPING AS REQUIRED AT AFFECTED AREAS,UNLESS OTHERWISE NOTED. ®ARCHITECTS 10. ALL ELECTRICAL LINES TO BE REMOVED OR GAPPED IN WALLS TO BE REMOVED (VIF). CONTRACTOR TO PROVIDE NEW OUTLETS AND 5NIT04ES THROUGHOUT THE HOUSE AND IN THE NEW WALLS AS PER ALL PERTINENT CODES AND LOCATIONS NOTED ON PLANS. CONTRACTOR TO PROVIDE NEW LISHTIN6 AS SHOWN ON THE PLANS AND TO REPLACE EXISTING FIXTURES AS PER OWNER. ALL WORK 62 Elm Street TO BE IN ACCORDANCE TO LATEST BUILDING AND ELECTRICAL CODE REGUIREMENT5. € L I 11. ALL DEMOLITION DEBRIS SHALL BE REMOVED FROM THE SITE AND DISPOSED OF IN A SAFE, LEGAL MANNER JOB SITE SHALL BE Huntington, NY 11743 FREE OF ACCUMULATED DEBRIS. A REFUSE DUMPSTER OF APPROPRIATE SIZE SHALL BE MADE ACCESSIBLE ON THE SITE DURING _ - - _ - - - CONSTRUCTION PERIOD AND SHALL BE EMPTIED ON A WEEKLY BASIS. CONSTRUCTION SITE SHALL BE BROOM SWEPT ON A NIGHTLY BASIS. Telephone: 631.367.0050 14. COMPLETION OF JOB,SITE 15 TO BE CLEARED OF EXCESS DEBRIS AND MATERIALS. JOBSITE TO BE BROOM SWEPT AND GLEAN OF FAX: 631.367.6636 DUST AND DEBRIS. ALL WINDOWS TO BE GLEAMED INSIDE AND OUT. THIS 15 TO BE DONE TO SATISFACTION OF THE ARCHITECT AND STEEL BILGD OWNER PRIOR TO REGEIVIN6 FINAL PAYMENT. GiambertoneArchitects.com CELLAR DOOR ENTRANCE TO REMAIN EX EXISTING DINING ROOM D ,k, FP PEMOL T ON LEEND CONTRACTOR TO REMOVE ALL WALL5,PARTITIONS OR PORTIONS THERE-OF REMOVE EXISTING SHEETROGK SHOWN THUS. ALL EXISTING PLUMBING AND ELECTRICAL LINES TO BE CONTAINED project: EXISTING ON WALLS AND GEILIN65. C = __- - THERE-IN ARE TO BE GAPPED BELOW FLOOR LEVEL. CONTRACTOR TO PROVIDE REMOVE EXISTING FLOORING. TEMPORARY BRACING AND/OR SHORING AS REQUIED TO SUPPORT REMAINING 57225 Main VESTIBULE EXISTING 57RZTURE AND PROTECT SAME DURING PERIOD OF CONSTRUCTION. REMOVE EXISTING SLAB AS REMOVE EXISTING TEMPORARY BRACING AND/OR SHORING 5HALL REMAIN IN PLACE UNTIL ALL OF i REQUIRED FOR NEW WASTE LINES, DOOR THE NEW STRUCTURE HAS BEEN COMPLETED. Road LLC � ETC. � 7j El EXISTIMS WALLS AND GEILIN65 TO REMAIN -CONTRACTOR TO PATGH/MATCH d / I I REMOVE EXISTING REPAIR ANY DAMAGE CAUSED BY DEMOLITION AS REQUIRED — STEEL COLUMN- 7 -- ---- - -- - - --- - - - - - - OLUMN_ - -- - -- - - --- - - = _ _ _ _ Z 1 NOTES: Southold, NY DRANINC75 ARE NOT TO BE 50ALED. REMOVE EXISTING I _ _= EXISTING WRITTEN DIMENSIONS SHALL ALWAYS ( ' number: EXISRT NG WALL COVERED TAKE PRECEDENCE. I€ 19-012 \\ I w l I \ PORCH EXISTING 1 I ii zlI II C,.............R ................................ ............................. - _ - - - - - 2.01_9-.1.2.-.0.2I.s.suedfo.rP.e.rm...i..t... ................................ _............. _......................... ................. KITCHEN __..._................................._..............._..._...................................EIN REMOVE 2020-02-10 Issued for Amendment EXISTIN&BAR i EXISTING I I N BANQUET TABLE I I I I I I �.......�_._......_.__.........__ _........_ w_ ._..._ _........._ .._..... _. I EXISTING I................_.............__.............__.........___..........__,._........... _._..._.._..........DRo u�l � I I I l El RAISED TO BE FLUSH I ( I I I € /- L =______ J I FRAMED I L _ EXISTING BAR I I � � — — ---� I I (No woRK) I I I - - - - - - - - - - J t EXISTING HALL I I I REMovE ��� EXISTING WALL F F I - -� ,' �' EXISTING r l`� I r l I I I REMOVEIL WALK-IN REQ. l— —I I I L _i l I I I EXISTING WALL I is NG y� REMOVE NI. EXISTING I EXISTING I I I DOOR EXISTING BATHROOM BATHROOMi I I -� L — EXISTING LOBBY / DEMO DEMO W' Q I I I II \ II \ �D� T INC BATH EXISTING BATH - - - - - - - J II .II \/ El II - - � 1 9�OF NE�� I I I I I I I I I I I I I REMOVEIE�CISTING I I I I I I i t . 1 f l I I I I I I CHIMNEY11 I I I I I I I I I 1 I I I I I I I I I I I I Issued For Permit i t I I I I I I I I I I I I I I EXISTING CHIMNEY - i TO REMAIN copyright: © 2020 AVGA II II II II II II II II II II II II III I I I I I I I I I I I I I I III REMOVE EXISTING THE REDCOPYRIGHT DRAWINGS,SPECIFICATIONS. AND OTHER DOCUMENTS I I I I I I I I I I I I I I I WINDOWS AND WALL PREPARED IT ANDREW V.GT INSTRUMENTS RUMENAND ASSOCIATES ARCHITECTS,P.C. (AVGA)FOR THIS PROJECT,ARE INSTRUMENTS OF AVGA. THFSfi DOCUAIEN'IS i l I r EXI STI N61 GOMMOI�I ROOM. I I I I I I I I I I ARE SERVICES FORT HE USE SOLELY WITH R1 FIW TO THIS PROJECT.UNLESS OTHERWISE PROVIDED, AVGA SHALL BE DEEMED THE AUTHOR OF THESE DOCUMENTS AND SHALL RETAIN ALLCOMMONLAW,STATUTORY AND OTHER RESERVED RIGHTS THAT THESE DOCUMENTS SHALL NOT BE USED BY THF. OWNER, OR OTHERS, ON OTHER PROJECTS FOR ADDITIONS TO THIS PROJECT, OR FOR THE COMPLETION OF THIS PROJECT FOR OTHERS. II II II II II II it ► I it II II I III II II II it II II it II II II II II III II II II II II II II II II II II II Plotted: Monday,February 10,2020-12:19pm By: dermis I I I I I I I I I I I I I I { File: L\AVGA Cw=t Jobs\North Fork Table 19-012\Working Drawings\A2. II II II II II II II II II it II II II II II II II II II II II II II II II 11 II II II II II II II II II II II II 11 ............._........... I I I I I I I I I I I ifle: LL _ _ Demolition EXISTING \ — — F.P. I Floor Plan EXISTING DOOR 1/4 t.lxa i.: DMR Demolition Floor Plan SCALE: 1/4" = V-0" {{ I i f f L [i s qi € j`E ANDREW Ve BRICK € F GIAMBERTONE PROPOSED EL.E`TR'G SERVICE BRIGASSOCIATES & K 8°XI o 0 6" CONCRETE °ARCHITECTS ° PIER �.Fel. -fl EXIS TNG ELECTRIC FOST ( SIM ICE TO ATED BE 62 Elm Street UP m NEW DOOR g�°DIA. � 4° DIA. Huntington, NY 11743 3'0 X custom hgt. M.R COL 57L.COL. AHI Telephone: 631.367.0050 Y Fax: 631.367.6636 8°XI6"CONCRETE SLAB ON GRADE ` GiambertoneArchitects.com PIER I � ..�....._._..._..._.._.._......_.�_...-.............. _� 15TIN6 3X6 .... EX.6X6 E P,.1'S 240 O.G. POST EXISTINO 3X6 FULL F.J24°O.C. 57225 Main EX.W12 STEEL BEAM Road LLC BRICK — 12° MIN BEARING ON SOLI c UP BEARING(FIELD VERIFY) BRICK I W-01FMAXE15YT SPAN Southold, NY EXISTING SLAB IELD ON GRADE _ job number: � EXI5T1NG AH2 € CRAWL SPACE m 19-012 N > 41-4" d : ........... ....._......................................................................................................................................................... GAS , U)IL METER WATER ....................... 0HY%4 _ 2020-02-10 Issued for Amendment SERVICE j 4- I. . ................._._......... _........._._.._._.....__........._._.._... .. .. ___._._....._-_.-------__...........-.------ ...._.._..� C PIT1_-._._...._...__..........__..........._.._..�..._......_.__....._...._..___._.._.....____-...._..�.......___..._.,...._.............._._.. 1 BRICK STONE i 4 € S D Afft SHT 4 � dil�li I 14 i Ali' �9 .OF NEW�o { Issued For Permit 1 EXISTING SLAB ON GRADE cop-yrio t: © 2020 AVGA THE COPYRIGHT DRAWINGS,SPECIFICATIONS, AND OTHER DOCUMENTS j PREPARED BY ANDREW V.GTAMBERTONE AND ASSOCIATES,ARCHITECTS,P.C. (AVGA)FOR THIS PROJECT,ARE INSTRUMENTS OF AVGA THESE DOCUMENTS ARE SERVICES FOR T FIS USE SOLELY WITH RESPECT TO THIS PROJECT.UNLESS OTHERWISE PROVIDED, AVGA SHALL BE DEEMED THB AUTHOR OF THESE j DOCUMENTS AND SHALL RETAIN ALL COMMONLAW,STATUTORY AND OTHER RESERVED RIGHTS THAT THESE DOCUMENTS SHALL NOT BE USED BY THE OWNER, OR OTHERS, ON OTHER PROJECTS FOR ADDITIONS TO THIS PROJECT, OR FOR THE COMPLETION OF THIS PROJECT FOR OTHERS. 1 Plotted: Monday,Febrnaty 10,2020-12:20pm By: densis File: L•\AVGA Cur=t Jobs\North Fork Table 19-012\Working Dtawinp\A2.6 ........................_...............-.._...........V..............._.._.._.........._.............__....._........__............_._._..._..._ ..__...1 Exisfin-a Cellar Exi s tin Cellar - ! .:3&:' e: 1/411 = 1'-0" SCALE: 1/4" = V-0" (Ir :wn.: DMR t f [i[[ E F .......... ..................................................................................................... .......................................................................... F S EXISTING SELF THE SUPPORTING CONSTRUCTION SHALL BE GL051N6 DOOR PROTECTED TO AFFORD THE REQUIRED W/PANIG DOOR FIRE-RE515TRIGTIVE RATING OF THE HORIZONTAL MP AND R V. HARDWARE ASSEMBLY SUPPORTED. 2 HR RATED. PROPOSED REVISED KITCHEN LAYOUT PER SCDOH FOOD - -- I I -- -- A'PER SERV I GE PERMIT SUBMITTED BY P.W. 6RO55ER CONSULT I NCS ���`� , -- _- +,s ICG ON JAN. 21 2020 HSS3X3XI/4 `�� " Tti� GIAMBEll."JvLONE COLUMN ON H553X3X3/I6 COLUMN STEEL BILGO T X X7 BASE PL CELLAR DOOR I I ON b"X "X6" BASE PL & ASSOCIATES „ II „ l ' PROVIDE 2 LAYERS ' GWB TYPE X EXISTING W/2x4 WOOD STUDS ® 16"O.G. ENTRANCE TO REMAIN EXISTING _ _ _ __ -NEW WS X_21 FLUSH _ __ JOINTS FIN15HED EXISTING f-- -_ UL Des 0301 -- ---- "r—- -------------±' j `; '; -----__--_ . .............................. ...................................................................................................................................................... EXISTING FINISHED FLOOR EXISTING FINISHED FLOOR EXISTING J" PLYWOOD 5UBFLOOR SAFE AND SOUND ROCKPNOOL 5" THICK EXISTING FINISHED FLOORS.7 EXISTING PLYWOOD 5UBFLOOR EXISTING CEILINGJOISTS EX15TIN6 PLYWOOD SUBFILOOR 5x6 HOOD J015T5 BLOCKING I" X NAILER PROVIDE 2 LAYERS r_,Vq3 TYPE "X" L J THEN APPLY FlorneOFF Fire Barrier Pc 21-:211 PROVIDE 2 LAYERS 61615 TYPE "X" UL 263 PROVIDE .2 LAYERS J" 6N13 TYPE "X" A NDR E W V. I" X NAILER THEN APPLY FlarneOFF Fire Barrier Point UL 265 1" X NAILER AND I" ACOUSTIC PANEL THEN APPLY FlameOFF Fire Barrier Point I" X NAILER AND I" ACOUSTIC PANEL I x 5,, ACTUAL BEAM 26" O.C. UL 265 T GIAMBERTONE I X 5" ACTUAL BEAM 26" O.C. Ix NAILER AND I" THK. ACOUSTIC PANEL 2"x5" (ACTUAL) BEAM :26" O.C. & ASSOCIATES 0;�.- 0200" *ARCHITECTS 1 jypical Ceffing Construction Dropped Beam Detail 4 2 Hour Fire Assembly �OF A3 SCALE: 1-1/2 11 -011 A3 SCALE: 1-1/2" 1'-0" A3 )sc= 1-1/2" 62 Elm Street V-0" Huntington, NY 11743 Telephone: 631.367.0050 EXISTING FINISHED FLOOR Fax: 631.367.6636 EXISTING J" PLYWOOD 50FLOOR com CAVITY FOR THEN APPLY FlomeOFF Fire Barrier Point 'T --- x x I ! 1 PROVIDE 2 LAYERS &18 TYPE "X" ___ _ _ _ __ GiambertoneArchitects. UL 263 sH RECESSED LiTIN6 SEE r I/A5 - :2/A3 L K ............ I' DECORATIVE WOOD -N / I j �, I I I i = BEAMS 1-1/7'x3" 26"O.C. project: �N' F_ w �,�2.6 ' 57225 Main IJ .2,-2" F21-21 2'-2.. 2._2..2" = - -� CAVITY FOR RECESSED LIGHTING L 0 2XU2 116HT— 2 IXTURE Road ............ 1-1/2'xS" (ACTUAL) BEAM Ix NAILER AND I" THK. ACOUSTIC PANEL F BbOOK 26110C. PROVIDE UN�,ERI`Of��16 2X2,11 L CE, MAGUq HUNG EILIN(5 PROVIDE UNPERFORATED X2 Souffiold NY ; CERAM puwr) HUN6 CEILI�65 number NcV : I', jo E� �� � .I I � I. _ 1 �� 19-012 ............. 2 Tvnical Ceiling Recess for L hdng fd a­i e .................... ............. ................. ................... .......... ........... A3 SCALE 1-1/211 11-011 LED 2X4 LIGHT ..................................... ................................................................................................................................................ Two Hour Fire Assembly FIXTURE 3000K 1 -02-10 Issued for Amendment 2020 DROPPED 5TEEI BEAM = DROPPED STEEL BEAM 2020-03-12 Revised for Bldg Dept CLADDED 2 L4ERS FIRE GLADDER 2 LAYERS FIRE ..................................................................................................................... . ............ ........................... .. .... JL51­11ZE:0,ZorK AND RATED J" 5HEETRocl< AND RATED T INTUMSCENT FAINT THEN IN N_rP1NT rLADDI�D HITH DECORATIVE CLADDED WITH DECORATIVE YNioop EAM­TYPrAL At WOOD BEAM--TYPCAL AT DROPP DROPPED BEAMS ......................................................................................................... ............... ......... ........... ............... k ............................................................................................................................................................................................... ELECTRICAL LEGEND _7 ITEM SYMBOL D .................. ...... .................... ................................... .............. ESCRIMON J-BOX FOR SURFACE-MOUNTED CEILING LIGHT FIXTURE SUPPLIED BY OTHERS.NOTE: LETTER x x A DESIGNATIONREPRESENTS SELECTION AS ..................................................................................................-........................................................................................... IDENTIFIED IN SEPARATE SCHEDULE .............. AIR L.E.D. RECESSED SQUARE VOHNLI6HT -Ea. Ea Z-15/4'. x L.E.D. RECESSED DIRECTIONAL ACCENT POHINI-161-IT -7E:Ij 0 L.E.D.FUCK LIGHT I 0208t T-iVW F -011 ............................................... ............................................................................................................................ 41-61 L.E.D.COVE OR UNDER CABINET LINEAR 1-1614TIN&- c St WS: Ea. , I — -- LEN5TH5 4 LAMP SPACING TO SUIT DESIGN Fj_ . .. i t a E_j REQUIREMENTS x x x Issued For Permit .......... ................... ..........*................**............ SURFACE-MOUNTED EJ 1 L copyr0t: FIXTURE 0 2020 AVG ............................I.........................................................................................­............................................................... THE COPYRIGHT DRAWINGS,SPECIFICATIONS, AND OTHER DOCUMENT. WALL-MOUNTED LIGHT FIXTURE SUPPLIED BY PREPARED BY ANDREW V GLUMERTONE AND ASSOCIATES,ARCIMMS,P x OTHERS.NOTE: LETTER DESIGNATION REPRESENTS coI I x x (AVGA)FOR THIS PROJECr,ARE INSTRUMENTS OF AVGA. THESE DOC )MM U ARE SERVICES FOR T HE USE SOLELY WITH RESPECT TO THIS PROJECT.UNLFS, SELECTION AS IDENTIFIED IN SEPARATE SCHEDULE. OTHERWISE PROVIDED AVGA SHAI.L BE DEEMED THE AUTHOR OF THES1 DOCUMENTS AND SHALL RETAIN ALL COMMONLAW,STATUTORY AND OTIM RESERVED RIGHTS THAT THESE DOCUMENTS SHALL NOT BE USED By TH OWNER, OR OTHERS, ON OTHER. PROJECTS FOR ADDITIONS TO THI EXTERIOR HALL-MOUNTED SECURITY LIGHT FIXTURE PROJECT, OR FOR THE COMPLETION OF THIS PROJECT FOR aITIEN ...................•.•-•....-............................................. ................................................................................................ EXISTING EXP05ED Plotte& ThufsdayMarchl2,2020-9.40arn By: dennis INDICATES(5F;ZOUF5 OF LIGHT FIXTURES 4/OR HOOD BEAMS File: L-\AVGA Current jobs\North Fork Table 19-012\Working Draw!V\j RECEPTACLES1AV COMMON SWITCH FUNCTION 4� 4� ............................................................................................................................................................................................ SINGLE POLE SWITCH dfle: THREE-WAY SWITCH 1St Floor Reflected DUPLEX RECEPTACLE 5,-v L 51_011 Ll Lo" L 5'-0" Ll 51-011 L I Lo" 11 I'-b"1 1 51-011 Ll 5,-v L 3'-0" 1 Ll 31-011 GFI DUPLEX 6FI RECEPTACLE x x x x Cern Plan .......................................................................... X WP DUPLEX WATERPROOF RECEPTACLE -j I scale: 1/4 1-0 0 i -------T_ ............ .................................................................................................................................................................. APP? dna Nvn. DEDICATED APPLIANCE RECEPTACLE J, T T_ x x x Reflected Ce' gg Plan SCALE: 1/4 1'-0" ............................................................................................................................................ ............................... 3 •�;hj. f o T: FH9S ANDREW V. GIAMBERTONE NJ Sc & ASSOCIATES a o *ARCHITECTS 0 0 ,F 62 Elm Street HS Ps sC _ Huntington, NY 11743 D sc Telephone: 631.367.0050 Fax: 631.367.6636 GiambertoneArchitects.com __...... a project: FFqK gid; _. ,,,•;s 57225 Main Road LLC 3 a Southold, NY FIRE ION f 19-012 su� '' QRELAY ' H <, CSL4: 2020-02-10 Issued for Amendment I 3 \\ HS , y �s N, • \� f � 1 \ '. V I I I _ — — — _ w _ _ — _ Ps _.�. _.....__....._..... _ .._.__._.___.-....._...._.-_........__ ..._..__..._ ' EE( 0 E TYPICAL SINK/DRAIN DETAILS . f 3 E M. 04 mmm 071 aftM E 2 S I i6 Me[14= AND REFI V. E 0�'_0QL3 P R nous) 0 "� �3/4 � D 0®��® GIAMBERTONE ; C� ❑❑®❑ 4 dC ❑❑� 1 [4 W _ a 30®030000� CAST u."N.,wa e & ASSOCIATES 100 4 X67 aF o tl�v stemom ®ARCHITECTS 411 _ _E OI �--►n ; 62 Elm Street F 14 [368130] 4-�•O Huntington, NY 11743 O Telephone: 631.367.0050 46. cm' �'�' EXISTING I I Fax: 631.367.6636 4" 414' �i' ��-- cw CELLAR [10.67] 4 GiambertoneArchitects.com SQUARE HOLES r 8" % 8" I,_^p 128 [314.603 SQ. I cw 8" 11j 1298.453 SQ. CDFA ilASMAY I ^� • " �€,: THRU j I 21 C60.353w _ I I 57225 Main I-amfrn 2 ._. »� cob,. P tee: _ Road LLC 86 1206.383 DFA �I 8" c 10 [257.18] 9j C247.653w 3.s Iaow STIA,UP I-88 51-40 2'-8r g.-4r 4' 1 21 Southold, NY ( t II7I .., :x »• al p 4. 4p € � ) NO-HUB 4° I' 19-012 TY-SEAL E IQ • tc: FLOOR DRAIN ......................................................................................................................................���������2020-02-10 Issued for Amendment ..................................: Z'_8r � COWL_ co N IPE E, 1 p PTT pt Pt O E O ® CAH. .................»........_......._.. _..............,......................_....._...........__...._.__........_«......__................_........_...... PT g-4• fl�gn Ilr(n ��In 8" 12" AT KITCHEN AREA t � EX15TINS SLAB ON GRADE TO BE REMOVED AND QQ❑®❑❑0o INSTALL NEW b" P.G.SLAB OVER 6 MIL VAPOR ❑❑❑®❑❑❑❑ BARRIER WITH 2" Dow -- -- �- ❑®❑131313131313 BOARD (INSULATION ON 5" ❑❑❑❑1313❑ O®❑000000 000000 E30 ❑81313130 E313 13 ® ❑13 DA ❑❑130130131313 `y� EN'S Q TFO� E3 1313130013 oo 00 000 ❑ ! ❑ ® 0❑❑ 00 000000 fi 80 000000 U0 000000 �� sTq 0208103'yoe�- SOF N ®❑❑131300❑ iw O TES - �' - gta# (� N GENERAL PLUMBING O Issued Foy Permit 1. ALL WORK DONE IN ACCORDANCE WITH ALL LOCAL CODES. 14'-2" 4'-4" 4' copyright: © 2020 AVGA 1 n 2. ALL WATER LINES TO HAVE SHUT-OFF VALVE. 12 44" 3. PLUMBER TO PROVIDE DISHWASHER HOT WATER AT 140'F MINIMUM ; THE COPYRIGHT DRAWINGS,SPECIFICATIONS, AND OTHER DOCUMENTS CONSTANT SUPPLY. ® PREPARED BY ANDREW V.GIAMBERTONE AND ASSOCIATES,ARCHITECTS,P.C. qry,a (AVGA)FOR THIS PROJECT,ARE INSTRUMENTS OF AVGA. THESE DOCUMENTS AM 4. ALL INTERCONNECTING AND FINAL CONNECTIONS BY PLUMBER. ��NN OTHERWISE PROVIDED, AVGA SH LL B DEEMED T THIS PROJECT.UNLESS C�'I'IIERwISE PROVIDED, AVGA SHALL BE DEEMED THE AUTHOR OF THESE 5. SEE PLUMBING ENGINEERING PLANS BY OTHERS FOR COMPLETE EXISTING SLAB DOCUMENTS R AND SHALL RETAIN DOCUMLL ENTS S AW,STATUTORY AND OTHER RESERVED RIGHTS THAT THESE DOCUNffiJf5 SHALL NOT BE USED BY THE SCOPE OF WORK AND PLUMBING SPECIFICATIONS. ON GRADE PATCH AS OWNER, OR OTHERS, ON OTHER PROJECTS FOR ADDITIONS TO THIS REQUIRED TO PROYDE E PROJECT, OR FOR THE COMPLETION OF THIS PROJECT FOR OTHERS, 6. THE HOT WATER HEATER TO BE SIZED TO MAXIMUM USE DEMANDS DRAINS AND PLIUMBING j Plotted Monday,February 10,2020-1216pm By dermis PLUMBING SYMBOLS LEGEND OF ALL PLUMBING FIXTURES. I Ede: L•\AVGA Current Jobs\North Fork Table 19-012\Working Drawings\A2.0, 7. PLUMBER TO PIPE DRAINS FROM WALK-IN COOLER/FREEZER EVAPORATOR UNITS TO OPEN SITE DRAIN. USE COPPER PIPE ONLY. 0 HW. CW. DIRECT DRAIN STUB UP 8. PLUMBER TO SUPPLY AND INSTALL BACK-FLOW PREVENTERS ON ALL EQUIPMENTAS REQUIRED BY LOCAL CODES. ,....................................................._..........................................................................._...._......._..-................................._. 9. PLUMBER TO COMPLETELY INSTALL ALL HAND SINKS, FAUCETS, ® GAS CONNECTION STUB UP LEVER/iWIST DRAINS, AS PROVIDED BY K.E.C. Proposed Slab DIRECT STEAM CONNECTION 10. PLUMBER TO INSTALL VACUUM BREAKERS FOR ALL COFFEE AND o CONNECTION ICE MAKERS. 11. PLUMBER TO SUPPLY AND INSTALL ANY REQUIRED GREASE TRAP OR lumbing-Floor Drain FLOOR SINK WITH HALF GRATE RECEPTOR AS MAY BE REQUIRED BY LOCAL CODES. SEE PLUMBING Kitchen-Bar Slab Plumbing and Drain Locations ENGINEERING DRAWINGS BY OTHERS FOR DETAILS AND SPECIFICATIONS. 12. PLUMBER TO INSTALL SHUT-OFF VALVE IN MAIN GAS LINE FOR FIRE SCALE: 1/4" = 1'-0" � 1 41� = 1�-O�� 1 FLOOR DRAIN EXTINGUISHING SYSTEM. VALVE PROVIDED BY K.E.C. MR 13. PLUMBER TO INSTALL FLEXIBLE QUICK DISCONNECTS, IF SUPPLIED � Y D FUNNEL FLOOR DRAIN BY K.E.C. (WHEN REQUIRED). 14. PLUMBING DRAIN LINES FOR WALK—INS BY K.E.C. REMOTE LOWBOYS FUNNEL FLOOR SINK BY OTHERS. 15. IF LOCAL CODE OR CONSTRUCTION DOCUMENTS MANDATE PITCHING TO FLOOR DRAINS AND/OR FLOOR SINKS R MUST BE NOTED THAT EQUIPMENT MIGHT ELONGATED FUNNEL FLOOR SINK NEED TO BE MODIFIED IN THE FIELD TO ACCOMMODATE THIS PITCHING. P 1