Loading...
HomeMy WebLinkAbout44180-Z g11FFOL/r G� Town'of Southold 3/7/2020 0 P.O.Box 1179 o • 53095 Main Rd 'r,�1 �a0�' Southold,New York 11971 _ CERTIFICATE OF OCCUPANCY No: 41119 Date: 3/9/2020 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2075 Pine Neck Rd, Southold SCTM#: 473889 Sec/Block/Lot: 70.-5-47 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/12/2019 pursuant to which Building Permit No. 44180 dated 9/17/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels as applied for. The certificate is issued to Wallace,Luke&Schmidt,Katie of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 44180 12/26/2019 PLUMBERS CERTIFICATION DATED Authorized Signature o�SUFFocKC TOWN OF SOUTHOLD �� ay BUILDING DEPARTMENT y TOWN CLERK'S OFFICE oy . SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 44180 Date: 9/17/2019 Permission is hereby granted to: Wallace, Luke & Schmidt, Katie 200 Monitor St Brooklyn, NY 11222 To: install roof mounted solar panels as applied for. At premises located at: 2075 Pine Neck Rd, Southold SCTM # 473889 Sec/Block/Lot# 70.-5-47 Pursuant to application dated 9/12/2019 and approved by the Building Inspector. To expire on 3/18/2021. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 Total: $100.00 Bui ding or Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. 1 x,20 19 New Construction: Old or Pre-existing Building: 1/ (check one) Location of Property: 20-7 5- i?t ne ue cam. House No. Street Hamlet Owner or Owners of Property: f_.Gc..�cQ �.(1 n o_r and haft e_ SL)),ntcl�(- P rtY� Suffolk County Tax Map No 1000, Section 1 O Block S Lot 14-1 Subdivision ' r Filed Map. Lot: �(� Permit No. `"t Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate Final Certificate: y (check one) Fee Submitted: $ O Applicant Signature OF SO(�r�,®l Town Hall Annex ~ ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G ® � sean.devlin(ir)_town.southold.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Luke Wallace Address: 2075 Pine Neck Rd city Soouthold st: NY zip: 11971 Building Permit# 44180 Section: 70 Block 5 Lot- 47 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Element Energy LLC License No: 52689-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures Combo SD/CO 11 Other Equipment: 10.08 Kw Roof Mounted Solar PV System w/ 32- Qcell Qpeak Duo G5 315W Modules and 32- IQ7-60-2-US Inverters, AC Combiner, AC Disconnect Notes. Solar Inspector Signature: Date: December 26, 2019 S Devlin-Cert Electrical Compliance Form As OF SOU'yo �8 ` S"TIN c�VeGK �# TOWN `OF SOUTHOLD BUILDING DEPT. cou765-1802 INSPECTION .], FOUNDATION 1ST [ ` ] ROUGH PL13G. [ ] FOUNDATION'-2ND- ' [ ] INSULATIOWCAULKING [ ] 'FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [- ] FIRE'SAFETY INSPECTION [ ] FIRE RESISTANT-CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL)4! " b��� [ ] CODE VIOLATION [ ] PRE C/O REMARKS: vid be G Sa - cSBGa/1 c(, b0 o w Clr .f o orGe C S'1 a r- > DATE ! INSPECTOR LUIGI CLAUDIO SCIANDRA, P.E. 5 Wesleyan Court• Smithtown,NY 11787-3011 •(631)543-2953•fax(631)543-1526 Cell.631-747-7497 E-mail:Ics4d(a)aol.corn _r ,w Sunday, February 23, 2020 , Town of Southold 13 MAR - 4 2020 53095 Route 25 PO BOX 1179 - r- Southold, New York 11971 Re: Certification Letter-Thirty-Two(32)315 W PV Roof Top Solar Panel Array, 10.08 kW DC Total Output,for Wallace Residence, 2075 Pine Neck Road, Southold, New York 11971 1 have reviewed the solar energy system installation in the subject topic on 10/19/2019. The units have been installed in accordance with the manufacturer's installation instructions and the construction drawings approved by the Town of Southold. The solar panel installation is in compliance with the requirements of the 2015 International Residential Code, the 2017 NYS Supplement to the Uniform Code, ASCE 07-10 and NFPA Standard 70 "National Electrical Code_" Markings in accordance with Section 690.53 of the National Electrical Code are provided. To my best belief and knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission, and conforms with reasonable standards of practice with the view to the safeguarding of life, health,property and public welfare. Sincerely, Luigi Claudio Sciandra Professional En ineer of NEW yo SClgNO��'F 060935A ON FESS1000, FIELD INSPECTION REPORT DATE COMMENTS - . �d t� FOUNDATION(1ST) ------------------------------- rA ----- C FOUNDATION (2ND) ZjO �y a ROUGH FRAMING& �1 PLUMBING P� y INSULATION PER N.Y. -3 STATE ENERGY CODE FINAL ADDITIONjkl,COMMENTS Z rn X 0 z x d 4 T;OVVV,NN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN BALL Board of Health SOUTHOLD,NY•11971 4 sets of Building Plans #L: (631)765-1502 Planning Board approval Fes: (631) 765-9502 /FO Survey Southoldtownny.gov PERMIT NO. �' [ Check Septic Form N.Y.S.D.E.C.' Trustees C.O.Application Flood Permit Examined 20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved 20 6 / Mail to: IE T GL-ec d Disapproved a/c 141D 4tyJl.t�,", -(-VLV,M, Phone: (6?;-( !'I L Expiration ,20 Building Inspector _ KATION FOR BUILDING PERMIT SEP 1 2 2019 Date ,2 nv-kpp ,- /0 ,20 / g INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the,applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or regulations,for the construction of buildings, additions,or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. ' ' ��l LLC--- (Signature of applicant or name,if a corporation) 7470 _5pund Ax U-kck NU I19SZ (Mailing address of applicant State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Name of owner of premises ' �p ` (As'on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. S'Z(p ag_ //F Other Trade's License No. 1. Location of land on ch proposed workwill be done: �- c o20`]S x�_ K)P—cjC �o0A &Laolc House Number Street y''" ' ``""'''''`'Hamlet County Tax Map No. 1000 Section 10 Block, `,i S Lot y'71 / \ «k: ,�-U �� li Sia i.,.ilk,A ,.t c,tk:(:''ti•1..1 y"! Subdivision Filed Map No. Lot i 2. State existing use and occupancy of premises andtenoed}sand occupancy of proposed construction: a. Existing use and occupancy SIcteahcj b. Intended use and occupancy &51r,l PVl hCLY 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal - Demolition Other Work -l0.08 Ku) PUsVkenn (Description) 4. Estimated Cost Fee Tt2m (To be paid on filing this application) 5. If dwelling,number 6f'dwelling units Number of dwelling units on each floor If garage,-number of cars 6. If business, commercial or mixed occupancy,`specify nature and extent of each type of use. I 7. Dimensions of existing structures, if any:,Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front, Rear Depth .Height Number of"Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law, ordinance or regulation?YES NO I , I 13.Will lot be re-graded?YES NO Will excess fill be removed from premises?YES NO 14.Names of Owner of premises ,Luke 'WclYace_ Address 2075-R. p )UerP V Phone No. W I--5Z6-a2&,7 Name of Architect , - Address Phone No Name of Contractor Uk7nEoL ktoERr,W LL6 Address qy70%prr)A,k..4Phone No. (61--)79-'�e?R3 i 15 a. Is this roe within 100 feet of a tidal wetland or a freshwater wetland. YES 'NO property � * * IF YES, SOUTHOLD TOWN TRUSTEES &'D.E.C.PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is,at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property? * YES NO * IF YES,PROVIDE A COPY. STATE OF NEW YORK) COUNTY OF:So-Ply being duly'sworn,deposes,and says that(s)he is the applicant I (Name of individual signing contract)above named, (S)He is the (C ntrac or,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application that all statements contained in this application are true to the best of his knowledge and belief,and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me,this �- day of 20 /9 4 64r- PATRICIA A MAY Notary Public NOTARY PUBLIC-STATE OF NEW YORK Signature of Applicant No. 01 MA4676634 Qualified In Suffolk County , My Commission EXP,03 Mach 30, 20`-`L '® guFir�iy _ BUILDING DEPARTMENT- Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 %rh Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 'rocier-.,.ribhert,!gtown,.,s6Uth6ld-.1 APPLI.CAtION-F-OR ELECTRICAL-INSPECTION— REQUESTED BY: Date Company Name: 0 11 LK- 7 IName: email:--License No.: _52Aq- 0,ci e P4dress: -0�1- 11, auLd Dax Phone No," JOB SITE INFORMATION: (All Information Required) 'M Name: ao Address: JOIS Cross Street: Phone No.: 2-(o-1 I - bzl 'IBIdg.Permit#: email: Tax Map. District: 1000 Section: -)0 RLQC-K---i-S- Lot!,i BRIEF DESCRIPTION OF WORK(Please Print Clearly) Circle All That Apply: 0?- -� ') Final Is job ready for inspection?: YE NO Rough In N�61 Do you need a Temp Certificate?: YE, Issued On. - ---- A required)Information- ( —1J I Serv-ide,Size 1 Ph 3 Ph Size: A # Meters Old Meterft New Service - Fire Reconnect- Flood Reconnect- Service Reconnected -Underground - Overhead `Pad �e Frame Pole ole Work-dQne on-Service? 1 2 --Y (id Additio---1 laftr-rifati K641 mou ::Additional Information: 'PAYMENT-tDUE-"WITH-APPLLCAT:,I-ON, elec 82-Request for Inspection Form As 1'7 1,1 OF SO(/p�®� Town Hall Annex ~ ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 0 • a� �yc®UNTI,a� BUILDING DEPARTMENT TOWN OF SOUTHOLD January 8, 2020 Element Energy 7470 Sound Ave Mattituck NY 11952 Re: Wallace, 2075 Pine Neck Rd, Southold TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: NOTE: Still need engineer's post installation certification let Electrical Underwriters Certificate o. A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1184) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT—44180 -Solar Panels New York State Insurance Fund Workers'Compensation&,01sabi ft Benefits Specialists Since 1914 8 CORPORATE CENTER DR,3RD FLR,MELVILLE,NEW YORK 11747-3129 CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) N* "*m AAAAAA 823338604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 102 mHUNTINGTON NY 11743 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATA 12449 444-5 131560 0711312019 TO 07113/2020 ?f2412019 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO.. 2449 444-5, COVERING THE ENTIRE OBLIGATION OF THIS POUCYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW VCH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTYPS:IIWYWILNYSIF.COMICERTICERTYAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS ANDIOR MEMBERS OFA LIMITED LIABILITY COMPANY. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:719279724 U-28.3 I+ J A&COM& CERTIFICATE OF LIABILITY INSURANCE '7750019 I _ } THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE FOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES I BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED I REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: if the certificate holder Is an ADDITIONAL INSURED,the policyges)must have ADDITIONAL INSURED provhalons or be 4ndmed. ! If SUBROGATION IS WAIVED,subject to the terms and Conditions of the policy,certain policies may mquire an endorsement, A statement on this ca3Meate does not confer rl hts to the certificate holder In lieu of such sndonwmemUs- PRODUCER . PRODUCER ROBERT S.FERE INSURANCE AGENCY Pp 23 GREEN STREET,SUITE 102 HUNTINGTON,NY 11743 JADDR ROBERT S, FEDE INSURANCE INSURER aFFOJLDING COvrIIr►Ge NAIc s INeuRFree aNSURED INSURER B .,STATE INSURANCE FUNU Element Energy LLC IaveuRERc ELEMENT ENERGY SYSTEMS IN3URERD: 7470 SOUND AVENUE INSUREREI MATTITUCK, NY 11952 INSURER F COVERAGES CERTIFICATE NUMBER; REVISION NUMBER. THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHIG THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN 13 SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE- -__ ADDL sU® POLICY NUMBER MOM P La cOtaareRCTAL GENERAL LUBILITY X X CLOO275204 7/1412019 7114/2020 EACH occURRENC : 1.0m o d A CLAIMS-MADE OCCUR PREM E Ea omrr&u i 10-0100D MED EXP ore a 500fl PEASONAL 3 ADV INJURY i 10Q0000 GEN'L AGGREGATE LIMIT APPLIES PER* GENERALAGGREGATE $ UK= POLICY❑.ilia%_ ❑Loc PRODUCTS-COMPIOPAGG S 2,0W,000 OTHER- i AurOMOBILE LIABILITY Ea NEp SINGLE LIMIT i ANY AUTO B=LY KRwy(Per( w) s OWNED SCHEDULED AUTOS ONLY AUTOS BODILYIN,KIRY(PereodiNN) I HIRED NON-OWNED PERTYQANAGE S AUTOS ONLY AUTOS ONLY s 1 X UMBRELLA X OCCUR XLDOO11240 7/14/2019 7/14/2020 EACHOLCURRENCE i 1, 'wo Excess UAB CLAIMS-MADE AGGREGATE i RED I I RETENTION i i WORKERS COMPENSATION PEAJIM EMPLOYERS LIABILITY YIN 124494445 X IM ANY PROPRIETORIPARTNEMEMCUIIVE 7/14!2019 7114/2020 OFFICERtMEMBER EXCLUDED? a N I A x E.L.EACH ACCIDENT S 1,000,000 (Mawatory In NH) x�s,desr�b&under E.L.DISEASE-EA EMPLOYE S DESCRIP ON OF OPERATIONS below IE.L.DISEASE•POLICY LIMIT 3 NY State Disability \ WDLI D279340 711412019 7!14120200 statutory 1 ESCRII►TION OF OPERATIONS I LOCATIONS r VEHICLES(ACDRD 1oi,AddNional Remarks Schedule,may be amehed B mon&Paw V mgmrq CERTIFICATE HOLDER LISTED IS AN ADDITIONAL INSURED CERTIFICATE HOLDER CANCELLATION Town of Southold SHOMD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EVMTION DATE THEREOF. NOTICE WILL BE DEI.f1tE M IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. ALTHORM REPRESENTATIVE Fed, Sr, CORD 25(2016103) The ACORD name and 1090 are registered marls offAACORI) CORPORATION. AA right'r+werved, LUIGI CLAUDIO SCIANDM, P.E. 5 Wesleyan Court• Smithtown, NY 11787-3011 . (631)543-2953 •fax(631)543-1526 E-mail*Ics4d@aol com Monday, September 09, 2019 P R01 S NOTED Element Energy Systems DATE B.P.#� 7470 Sound Avenue 05�_b FEE: BY. Pi Mattituck, New York 11952 NOTI BUILDING DEi'AT AT Tel. 631-779-4004 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: Attn.: Mr. Mike Lawton, Principal 1. FOUNDATION - TV110 REQUIRED r FOR POURED CONCRETE anwo Re: Thirty-Two 32 315 W PV Rao %K I HTI NAMING & PLUMBING ��, °� Solar Panel Arra 10.08 kW DC Tota u Mr,;STRUCTION MUST CIOWallace Residence, 2075 Pine Neck Road, Southc dr,NqwvY1orkM97A ALL CONSTRUCTION SHALL MEET THE Dear Mr. Lawton: REQUIREMENTS OF THE CODES OF NEW ic�z ESPO°JSIB E FOR Pursuant to your request, I have reviewed the following infor 16 o ��v' f i�CP e r s, top solar panel array: • Cover Sheet with Site Visit/Verification prepared by E2Sys representative identifying specific site information including size and spacing of roof supporting element for the existing roof of the proposed system to include cover sheet, site plan, mounting and structural details. This information was prepared by E2Sys and will be utilized for approval by the Town of Southold and for construction of the proposed system. Based on the above documentation, I have evaluated the structural capacity of the existing system to support the additional loads described below, imposed by the solar panel arrays and offer the following comments. The existing roof types are as follows: COMPLY WITH ALL CODES OF Residence Roof, Array 1: NEW YORK STATE & TOWN CODES Single layer of asphalt shingles, AS REQUIRED A7ia: F 5/8" plywood decking, 2"x8" at 16" on center Douglas Fir rafters, 2"x8" Douglas Fir ceiling joists at 16' on center, D 2"x4' Douglas Fir collar ties at 32" on center, Roof pitch 370 . N.Y,S: Structural Analysis: The structural analysis has been carried out using the following design cri Design wind speed: 130 mph Ground snow load: OCCUPANCY O 20 lbs/sq. ft. USE 6S UNLAWFUL 1 WITHOUT CERTIFICATE OF OCCUPANCY • t Solar Array 1, Dead Load: 2.74 lbs/sq. ft. Total Unit Weight of Array 1: 800.8 lbs The above values are within acceptable limits of recognized industry standards for similar structures. The structural analysis, performed for the existing structure and for the solar panel arrays, utilizing the above design loads, indicates that the existing roofs will be able to support the additional panel weight without damage, if installed correctly.The onsite inspection and the photographs show that the roof framing is in good conditions. However, the building owners are to be made aware that long term build up of heavy snow conditions may produce deflections in the roof structure. If any deflection is noticed, than it is recommended that the solar panels be cleared of accumulated snow more than one(1)foot deep over a period of one week. If no deflections are visible under any snow loading over a period of time, then there is no need to clear the solar panels. Based on the above evaluation, it is the opinion of the undersigned professional engineer, that with appropriate solar panel anchors being utilized, the roof system will adequately support the additional loading imposed by the solar panel arrays. This evaluation is in conformance with the 2015 International Building Code,the 2017 NYS Supplement to the Uniform Code, SEI/ASCE 7-10"Minimum Design Loads for Buildings and Other Structures", 2014 NFPA Standard 70"National Electrical Code", current industry standards and practice and based on documentation and data supplied by Mys atthe time of this report. Should you have any questions regarding the above or if you require additional information, do not hesitate to contact me. Sincerely, L igi Claudio Sci ndra, P. E. OF NEW yo y�JAG`G.sciA p�f v `y �0 080935- ARcFESS10NP" 2 DE51GN 4 DRAFTING BY: JAMIE MI SCOPE Of WORK i NABCEP CERTIFIED TO IN5TALL A 10.08 KW SOLAR PHOTOVOLTAIC(PV)SYSTEM AT THE WALLACE RESIDENCE, os l 112-129 LOCATED AT 2075 PINE NECK ROAD, 5OUTHOLD, NY 1 1971. THE POWER GENERATED BY THE PV 5Y5TEM WILL BE INTERCONNECTED REVISIONS WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. ' THE PV 5Y5TEM DOE5 NOT INCLUDE STORAGE BATTERIES, DE5CR1pnoN I DATE REV ORIGINAL 06-30.2019 SYSTEM RATING 10.08 kW DC 5TC EQUIPMENT SUMMARY ,f �,F? l ti •� y 32 QCELL5 Q,PEAK DUO BLK-G5 315 PV MODULES '°? - CONTRACTOR32 ENPHA5E I07-GO-2-U5 MICRO INVERTERS ' I IRONRIDGE XP 100 MOUNTING 5Y5TEM ELEMENT ENERGY, LLC. SHEETINDEX 7470 SOUND AVE �"� � � � f� MATTITUCK, NY 1195 Pv-I COVER LICENSE# 43889-H PV-2 51TE PLAN 1" PV-3 ROOF PV LAYOUT LICENSE # 52G89-ME PV-4 5TRUCTURAIJ DETAIL5 SECTIONS ~; r PV-5 3-LINE ELECTRICAL DIAGRAM GOVERNING CODES r PROJECT NAME 2014•NATIONAL ELECTRICAL CODE. 2015 INTERNATIONAL RESIDENTIAL CODE AND NY5 2017 SUPPLEMENT. UNDERWRITERS LABORATORIES(UL)5TANDARD5 L PROJECT LOCATION LJ Q 05HA 29 CFR 1910.269 GENERAL NOTES - - 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT U �- ' ��., k �::•ar:� '.,iii ,, 'h`= THE 51TE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE "" t' r• ?;�h " W y' .w f S AND MAKE WORK w , Jf; HIMSELF WITH THE INTENT OF THESE PLAN .: M, 4'*',*' ;y " ` " � $" R Z AGREE THE SAME, � � =Awa..•�'} � �.w 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED '' W :' *' W «Y�`'S +�L'v &UiS3 S';iT;����" O APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, 10. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. K,j"`'``Y U z y :i i3ifcr`a "rs.� L'-t=', sF :ij.r.,.' INSPECTION APPROVALS, ETC„ FOR WORK PERFORMED FROM .CONTRACTORS LIABILITY, WORKMAN'S COMPENSATION, �,-i,�.�;''• _ THEREOF, IF REQUIRED, JURISDICTION T R AVING AGENCIES HCOMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES � � F-- 3, ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND OF THIS PROJECT AND FURNISH PROOF OF SAME PRIOR TO �� x ` a, �:;. �x £=z'���K�; " �`y _. Q � D ALL RULES AND REGULATIONS OF THE RESPONSIBLE COMMENCING WITH WORK. :r '^ `` sr �5 O O JURISDICTION, FOP, I I. EACH SUBCONTRACTOR SHALL BE RESPONSIBLE :ep5,a •:, +� "i y- �� 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS , WHICH DISAGREES WITH THAT AS INDICATED ON THESE PLANS, MAINTAINING SAFETY ON THE JOB SITE DURING THE .,• ,^" �� ; CONSTRUCTION PHASE TO COMPLY WITH THE REGULATIONS THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND ENGINEER. SHOULD HE FAIL TO FOLLOW TH15 PROCEDURE AND HEALTH ADMINISTRATION, THIS SHALL INCLUDE, BUT ARE NOT <�,,�,r^.zv•ts ,=,: '' ;«n �',sem.. '`,'rs,•V'h• ': ,}w, CONTINUE WITH THE WORK, HE SHALL A55UME ALL I ,.r;,- T{ iE - ' r„ „x,,r. r. 5HEET NAME LIMITED TO. PROVIDING FOR ADEQUATE AND PROPER BRACING, w; , ,, RESPONSIBILITY AND LIABILITY THEREFROM <._ 5. ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL BE SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY �a' 'ttl�,r„ , + ,��•�� a� •� �,,Arc,.., ,.i y,,; �' • , SCAFFOLDING, STAIRS, ETC„ AS WELL AS PERMANENT p FABRICATED AND INSTALLED A5 PER LATEST A,I.5.0 _ V CONSTRUCTION. COVER y,," ,� SPECIFICATIONS. 12. FIGURED DIMENSIONS SHALL GOVERN, DO NOT SCALE -=y `+ a' G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE DRAWINGS,WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING "' <JY UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.G. +! � �. � n• a;;l. CONDITIONS, EACH CONTRACTOR SHALL VERIFY EXISTING `` t NYS CODES t REGULATIONS k`4ozam CONDITIONS PRIOR TO ORDERING MATERIALS AND 7, ANY DEVIATION FROM THESE PNS WITHOUT THE WRITTEN ` ` ' IATHE ENGINEER'SCOMMENCING WITH WORK. �> ' `" '' `' "'' 7'' 'r" DRAWING SCALE , a ;" } �> ?.,'' CONSENT OF THE ENGINEER WILL NEGATE 13" CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY THIS '...,;,• CERTIFICATION OF THESE PLAN5. m '� r. 8 T 8.THESE DRAWINGS AS INSTRUCMENTS OF SERVICE ARE AND WORK FROM THE SITE AND DISPOSE OF IN A LEGAL MANNER ON �, ..r rv.,��,`;�wp�a'�u"r ``�'"` �, �.' ,�f'�';a'�' �s,*„ x;�.,� -'z. meq` '��';i`�% � . I ,S, A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT. 3 r� ' "'S' '�� �� F A"` AIN THE PROPERTY OF THE ENGINEER WHETHER THE SHALL REM 14. AT THE COMPLETION OF WORK,THE SITE TO BE CLEARED � ``�'�"� �`� • '' �`�" `''"�`"' �' .`T,, PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. OF ALL DEBRIS AND EXCESS MATERIALS. THE FACILITY IS TO BE THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR1 EXTENSIONS TO THIS PROJECT LEFT BROOM CLEAN AND WORK IS TO BE COMPLETED TO THE + 4 - � rir ;a�, .�.,?s��<<�� SHEET NUMBER 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF EXISTING WORK ADJACENT TO H15 WORK, OR DAMAGED A5 FINAL PAYMENT, AERIAL VIEW >"'V- I RESULT OF HI5 WORK. DE51GN DRAFTING BY: JAMIE MINNICK CER J G NABCEP CERTIFIED 051112-129 — - REVI5ION5 DE5CRIFTION DATE REV ORIGINAL 08-30.2019 s ot+{7y~V�' CONTRACTOR I N 11 II eP� W I � 2 -2 5 N .e �,-' ELEMENT ENERGY, LLC, N g6 7470 SOUND AVE v MATTITUCK. NY 1195 v LICENSE # 43889-11 ADDITIONAL ROOF VENTING LICENSE # 52G89-ME j - J ACCE55 AT GABLE ENDS -' PROJECT NAME ADDITIONAL ROOF VENTING_. I__.' .__ ACCE55 AT GAB E ENDS I u �------ 31. __{ I III __.2 -54 Lu O m 3 04 -- -- g _72 - — Qa O) N W t U >- 11-0 1 II---- 1 Lo z o oro LudoV. z 2I�2II Spq, , ov N N W Z ! / ` J i N U - 0 _ — J Ln I— LEGEND O 0 30 FIRE 5ET13ACK/ACCE55 PATH I ®MMAIN AE UTILITY NETER IN SERVICE PANEL 3G"x 30 GROUND ACCE55 TYP. SNEW PV SUB—PANELS A/C DISCONNECT COMBINER INVERTERS 5HEET NAME ® GND ELECTRODE I O N PV MODULE APVFtAMO G RAIL S 1 TE PLAN o ATTACHMENT POINT ---RAFTERS -*--ROOF PITCH ANGLE DRAWING SCALE ®SUNRUN MOM ®VENT N .T.S. OPLUMBING VENT CONSTRUCTION NOTES ®err LIGHT 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE ®CHIMNEY 5HEET NUMBER MANUFACTURER'S INSTALLATION INSTRUCTIONS. ®COMPOSITE SHINGLES p\ / 2.)ALL OUTDOOR EQUIPMENT SHALL BE RAINTIGHT WITH MINIMUM NEMA 3R RATING. rirr PO�TIIAALL SHADING ISSUES I V '-2 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. QTRIM/ItEMOVE AS NECESSARY CONSTRUCTION SUMMARY DE5IGN E DRAFTING BY: (32)QCELLS Q.PEAK DUO BLK-G5 3,15 WATT PV MODULES o JAMIE MINNICK (32)ENPHA5E I07-GO-2-U5 MICRO NVERTER051112-129 5 O NABCEPCER (84)ATTACHMENT POINTS @ 6411 O�MAX. (370) LF IRONRIDGE XRI 00 MOUNTI G 5Y5TEM. ROOF TYPE = A5PHALT SHINGLE -_ 1 - '- ARRAY # I Z c �� pip REVISIONS CONSTRUCTION NOTES ; I _ 1 6 M O D U LES p o N DCINAL PION DAm REV OPJC,INAL 08.90-2019 1.)ALL EQUIPMENT SHALL BE IN5TALLED 370 PITCH = IN ACCORDANCE WITH THE MANUFACTURER'S IN5TALLATION IN5TRUCTION5. ( 840 AZIMUTH 2.)ALL OUTDOOR EQUIPMENT 5HALL — — BE RAINTIGHT WITH MINIMUM NEMA 3K RATING. J 3.)ALL LOCATIONS ARE APPROXIMAT AND'REQUI 21 211 �eP� aw- fIELD VERIFICATION. � � 7- 1 - > -n - - P__, D Q��j� CONTRACTOR Cn rn ��� ELEMENT ENERGY, LLC. Np 3�O MATTTCSOUND UCK,, NY I1952VE LICENSE # 43889-H l±± L II LICENSE # 52G89-ME 7 UE _rnI5 of N Si D !r PROJECT NAME ,ncrxar.�� Q — LLJ ENTING_ - I _ _ w W z - - - - - _�_ -- -- I_ I I 1 ry z ENDS f - — - - - - - _ - _ - -2 54 W Lu i rn SFS - > OO LEGEND � . I 17-d - meq ..�, �E%ISTTNG UTILITY METER _ = CT-,, MAIN SERVICE PANEL ��YY NEW PV SUB-PANELS - _ _ -_ _ _-_- _-. _ .� � ( L = Y------------_- ��C A/C DISCONNECT �'` -7-I I s- C� I �ss 5HEET NAME LNER OMB INVERTERS I D 2172 ® GND ELECTRODE 9®'PV MODULE - rn ______o ROOF D ETAI -RACKING RAIL ARRAY`Y #2 ' N O ATTACHMENT POINT ---RAFTERS 1 6 MODULES D DRAWING 5CALE f--ROOF PITCH ANGLE 370 PITCH 59SUNRUN METER 2G40 AZIMUTH N .T.5. OPWMSING VENT ®SKY UGIT, 5HEET NUMBER ®CHIMNEY 30 fIRE SETBACK/ACCESS PATH ®ate SHINGLES I PV-3 POTENTIAL SHADING.ISSUES, __.I=11RlM/.[2EMOVE�5_NECk�SARY�_�..____.._. LOAD CALCULATIONS ARRAY#12 (IDENTICAL) ITEM DESCRIPTION ARRAY#1*2 DESIGN s DRAFTING BY: Rafter 2"x 8" D-FIR I G"O.C. JAMIE CERTIFIED Modulee t 41 ,20 Lbs _ (D) Deckm 5/8"PLYWOOD N 051112-129 51 1BCEP 1 ER129 o M u e 1 6@32".0-C. � 05 I I 12-129 Total Module Wel ht 659.2 Lbs (C) Collar Ties 2"x 4" D-FIR @32"O.C. Total Len th of Rad 120 Ft (J) Ceihn Joist 2"x 8" D-FIR @ I G"O.C. REVISIONS (P) Pitch 37' DE5CRIFTION DATE REV Rad Wei ht per Foot 0.68 Lbs " MAX 2"x 10"D-FIR Rail Wel ht 8 I 6 L . bs (RB) Rid a Board/Beam rT (11) San Width of Rafter(R) 96" OPIGINAL Total Ra05-30-2019#of%a doffs 30 Wel ht er standoff 2 Lbs '- Total Standoff Wei ht 60 Lbs "' S§ ?, V Total Arra WeI ht 800.8 Lbs (R) {RB) Point Load 26.7 Lbs ,� - (D) Total Arra Area 29 I,97 5 Ft �" `�. Arra Dead Load 2.74 Lb5/5 Ft - CONTRACTOR / ( ) ELEMENT ENERGY, LLC, 7470 50UND AVE As per ASCE 7 - Method I: i 6-2 a e - (C) MATTITUCK, NY 1 1952 P net =� t I Pnet30 a 6-2 Kit(sec 6.5.7) i ne a e - # LICENSE # 43889-H CLIMACTIC AND Ground Ind Spee Live load, Point Max fastener LICENSE # 52689-ME GEOGRAPHIC DESIGN Category 5now Load 3 sec gust pnet30 pe pullout loo Fastener Type spacing along CRITERIA Pg mph A5CE7, ps Ib. rads, In. A # 20 130 # 468 5/1 G"x G"Stainless Steel 64" (Nop Roof Section B # TYP. TYP. # TYP. Lag Bolts PROJECT NAME # (�) For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=OA47 m/s. Lu Q a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as Z 0 determined from Figure R301.2(3).The grade of masonry units shall be determined from ASTM C 34,C 55,C 62,C 73,C 90,C 129,C 145,C 216 or C 652. b. The frost line depth may require deeper footings than Indicated In Figure R403.1(1).The jurisdiction shall fill in the frost line depth column with ROOF FRAMING DETAIL I the minimum depth of footing below finish grade. C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local W W z subterranean termite damage. ryz d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(4)A].Wind exposure Z ll_I LL_.I C) category shall be determined on a site-specific basis in accordance with Section R301.2.1.4. e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the MODULE MOUNTING CLAMP - U 0 International Plumbing Code.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience _ as determined by the building official. 50LAR MODULE - -f 'r ' f. The jurisdiction shall fill In this part of the table with the seismic design category determined from Section R301.2.2.1. STAINLESS establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and ''- ��- STAINLESS STEEL 3/8" < To g. ��. BOLT AND NUT Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a ,�- > Q minimum,special flood hazard areas as identified by the Federal Emergency Management Agency In the Flood Insurance Study for the community, ` . N as amended or revised with: -- 1.The accompanying Flood Insurance Rate Map(FIRM), — _---[ OR NRIDGE ALUMINUM RAIL li.Flood Boundary and Floodway Map(FBFM),and '- ALUMINUM"L^DRACKET iii.Related supporting data along with any revisions thereto. The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. ALUMINUM FLA5HING SFiEEf NAME h. In accordance with Sections R905.1.2,R905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of local damage from the effects of Ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this 5T RU CT U RA part of the table with"NO." i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index(BF-days)from Figure R403.3(2)or from the ASPHALT 5HINGLE ROOF 100-year(99 percent)value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F).' 5/1 6"X A STAINLESS r data table"Air STEEL LA J. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data CenteG BOLT WITH 2 I/2'MIN THREAD Freezing Index-USA Method(Base 32"F)." PENETRATION SEALED DRAWING SCALE k. In accordance with Section R301.2.1.5,where there is local historical data documenting structural damage to buildings due to topographic wind WITH GEOCEL 4500 speed-up effects,the jurisdiction shall fill In this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. (EQUIVALENT OR BETTER) I. In accordance with Figure R301.2(4)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill In this A5 NOTED part of the table with"YES"and m. In accordance with Section R301.2.1.2.1,the jurisdiction shall indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall indicate"NO"in this part of the table. In. The ground snow loads to be used in determining the design snow loads for roofs are given in Figure R301.2(5)for sites at elevations 0 e SHEET NUMBER 1000 feet.Sites and elevations above 1000 feet shall have their ground snow load increased from the mapped value by 2 Ibs/ft2 for every 100 feet FV-4 above 1000 feet. (") See Figure R301.2(4)B. MOUNTING DETAIL DE51GN 4 DRAFTING BY: 50LAR ARRAY(10 05 kw) JAMIE MINNICK %?)OCCUR O rtac VUO BLK GS 815 FV MOGUIL5 SOLAR MODULE TYP. (2)$TF NG OF(I G)M CRO mfer(EP5 NABCEP CERTIFIED ------ -'-[ — y 0511 12-129 - - - - - - - - - - N� - � - TO UTILITY GRID STRING#I - - n n - L ti - ti ti I i SIONS r- ------------------------ - G G c DATE REV I - [017PIGINAL06.30-2019 t-- -- ----------- °_----'G`----'�'�- '-- �`----'G Lv�O.___-.J _G� --Gl--_ (G�'_ G IG[�- - �c �G - '---- 2 N - ONAL bd � 1 ------------- BI-DIRECTIONAL - -- ------ -----' ---- ---- --- ---- -- UTILITY METER �--- --- —i �_----- I-PHASE,240 V I STRING#2 _ I i- ------------ - -- G _' -' G / - -'G - _ _ 1L ILl __J A 1 + IL - ,------------------- -G -'-�__" G -'-_•-f,±--I .r_..- -- --G.l"�'I _ G G G _ C C j I ENPFIASE BRANCH MICPO INVERTER 1 2 N POINT OF INTERCONNEC11014 CONTRACTOR , - CIRCUIT CABLE TYP. ENPHA5E 107.60-2-U5 / AC D15CONNECT _ PER NEC 240,21(3)(1)4 G90,6-I(A) i 1 240 VAC, 1 0 A- _ - 97%CEC-WEIGIITED EPP, 50 D D223NP.B --SMALLN Of TAP CONDUCTORS SMALL NOT EXCEED I O fl I NEMA G,UL LISTED 240 VAC,GO A NEMA 3R,UL US= ELEMENT ENERGY, LLC. IY (2)40 A FU5E5 MAIN SERVICE DISCONNECT I AC COMBINER BOX - --240V, 150 A 7470 SOUND AVE I 'NPnA"rACCOMBiNrnBOX a, �9 40n MATTITLIC:K, NY 1 195 240 V.NENA 3Z,UL 1151E0 t 1 1 Ll L1 ('2)2-POJEiSREAKERS 2•10V,20A ."RLICENSE # 43889-H �G N L LI I N L LI 2 2 LICENSE # 52689-ME FN II f ------------------------ a ----- -------1 Ll Ll aI 2 2 I I I 3 Ll L1 PROJECT NAME I R� r j 2 2 MAIN 5ERVICE PANEL Q " I I I Ph,3-V✓ W AC N Q) O 1 I I I 1 Wr-r� _ I I EXISTING GROUNDING ) I I ' I _J i ELECTRODE SYSTEM U �- L---------------------------------------------------------------------------------------------------------J i W z CLI WIRE CONDUIT SCHEDULE W IJ CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(% U Z 0 I.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DEBATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DEBATE D15TANCE 310,1510)(3) 310.15(15)(2aX21c) L STRING INVERTER AWG#10 1 4 0.8 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR 1" 709C 0.65 I 10 FT 0.8% {— OR EMT I� O INVERTER COMBINER PANEL AWG#6 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 45gC 0.87 25 FT 0.6% COMBINER MAIN PANEL AWG#6 I 3 1 THWN-2 AWG#8 I THWN-2 Cu PVC I" 4512C 0,87 I 0 FT 0.6% N ' 511EET NAME ELECTRICAL NOTES 1.)ALL EQUIPMENT TO BE L15TED BY UL OR OTHE2R NRTL,AND LABELED FOR ITS APPLICATION. CALCULATIONS FOR CURRENT CARRYING CONDUCTORS 2.)ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 909C WET ENVIRONMENT, #I PV Source Circuit Wire Am acit Calculation 3-LINE DIA. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY P y CONFIGURATION TO,AND LOCATED AS CLOSE A5 POSSIBLE TO THE NEAREST RIDGE. HIP,OR VALLEY. [NEC 690,,amp )): *T'(#of rate Con,56) = 20.8 A Modules per String 16 16 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL AWG# I O,ampacity'Temp Derate size FIII Derate= 20 A Modules per Inverter I COMPLY WITH NEC 110.26. 20.8 A> 20 A, therefore DC wire size is valid. Number of Inverters 32 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS CONTRACTOR 511ALL #2 Combined Inverter Output Wire Ampacity Calculation Record low tem -109C DRAWING SCALE FURNISH ALL NECE55ARY OUTLETS,SUPPORTS, FITTINGS AND ACES50RIE5 TO FULFILL Inverter Output Circuit OCP Calculation(Inverter Im )'(1.25) =40 A APPLICABLE CODES AND STANDARDS, AWG#6,derated ampacity'(Temp Derate)'(Conduitfill Derate) = 65,25 A Voc Tem Coefficient 0.24%/gC C� 6.)WHERE SIZES OF JUNCTION BOXE5, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, G5.25 A>40 A,therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS CALCULATIONS N .T.✓. THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. Operating Current 9 4 A =(#of 5trin 5)'(Im ) 7)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. #3 Combined Inverter Output Wire Ampaclty Calculation Operatmej Voltage 33 5 V =(#modules in senes)'(Vm ) 8.)MODULE GROUNDING CUP5 TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE Inverter Output Circuit OCP Calculation(Inverter Imp)'(1,25) =40 A Max.System VOltage 44.2 V =(#modules in series)'[(((-#.##%VlgC'.OI)'(Lo Temp##11C-25))'(Voc))+(Voc)] SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. AWG#6,derated ampacity'(Temp Derate)'(Conduit Fill Derate) = 65,25 A 9,)MODULE SUPPORT RAIL TO BE BONDED TO GONTINUOU5 COPPER G.E.C.VIA WEEB LUG 65,25 A>40 A therefore AC wire size Is valid Short Circuit Current 12,4A =(#of 5tnng5)'((5c)'(I.25)per Art. 690,8(A)(1) SHEET NUMBER OR IL5CO G5L-4DBT LAY-IN LUG. AC SYSTEM SPECIFICATIONS \/- 10.)THE POLARITY OF THE GROUNDED CONDUCTORS IS(positive/neLjative) Max AC Output;Current 40A OF, 10,)THE DC SIDE OF THE PV SYSTEM I5 UNGROUNDED AND SHALL COMPLY WITH NEC 690.35. O eratin AC Voltage 240 V