Loading...
HomeMy WebLinkAbout44178-Z ��o�gUFFQtkco�y� Town of Southold ` 3/7/2020 P.O.Box 1179 co 53095 Main Rd o4,� �aSouthold,New York 11971 CERTIFICATE OF OCCUPANCY - No: 41120 Date: 3/9/2020 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1600 N Oakwood Dr, Laurel SCTM#: 473889 Sec/Block/Lot: 127.-6-10 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 9/12/2019 pursuant to which Building Permit No. 44178 dated 9/17/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law..The occupancy for which this certificate is issued is: roof mounted solar panels as applied for. The certificate is issued to Kubetz,Jill&Jacob of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 44178 11/14/2019 PLUMBERS CERTIFICATION DATED Authorized Signature t.� TOWN OF SOUTHOLD ��o�g11Ff0(p ell, , BUILDING DEPARTMENT ' TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 44178 Date: 9/17/2019 Permission is hereby granted to: Kubetz, Jill &Jacob 1600 N Oakwood Dr Laurel, NY 11948 To: install roof mounted solar panels as applied for. At premises located at: 1600 N Oakwood Dr, Laurel SCTM # 473889 Sec/Block/Lot# 127.-6-10 Pursuant to application dated 9/12/2019 and approved by the Building Inspector. To expire on 3/18/2021. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 $100.00 Building Injector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial$15.00 Date. 0 2p l 9 New Construction: Old or Pre-existingBuilding: (check one) Location of Property: (100 Nod! (),.kjoono �UF_ House No. __II Street Hamlet Owner or Owners of Property: J-0-0-C)6 ( 1'1 C� Ta K LJ-"O—+Z Suffolk County Tax Map No 1000, Section "1 Block (P Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: ✓ (check one) Fee Submitted: $ J'—D gn Applicant Signature OF SO!/��,®l Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G sean.devlinCc�town.Southold.n us Southold,NY 11971-0959 y' ®lac®UNT1,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To. Jill Kubetz Address: 1600 Oakwood Dr city Laurel st: NY zip: 11948 Building Permit# 44178 section: 127 Block. 6 Lot 10 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Element Energy LLC License No: 52689-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures Combo SD/CO Other Equipment: 40- Qcell Qpeak Duo Blk 315-G5 and 40- Enphase IQ7-60-2-US Micro Inverters, Total of 12.6Kw System, Cagon Disconnect, Enphase IQ Combiner 3 w/ 2- 22013reakers and 1-210 Notes: Breaker Roof Mounted Photovoltaic System Inspector Signature: Date: November 14, 2019 S Devlin-Cert Electrical Compliance Form As of so / 6 A # # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INS PECTI0-N [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] -FOUNDATION 2ND ' - [ ] INSULATIOWCAULKING [ ] FRAMING /STRAPPING [ ] FINAL- [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION ] PRE C/O REMARKS: . DATE llq INSPECTOR LUIGI CLAUDIO SCIANDRA, P.E. 5 Wesleyan Court•Smithtown,NY 11787-3011 • (631)543-2953-fax(631)543-1526. Cell.631-747-7497 E-mail:Ics4d(cDaol.com Sunday, February 23, 2020 MAR - 4 2020 Town of Southold 53095 Route 25 PO BOX 1179 Southold, New York 11971 Re: Certification Letter- Forty(40)315 W PV Roof Top Solar Panel Array, 12-6 kW DC Total Output,for Kubetz Residence, 1600 North Oakwood Road, Laurel, New York 11948 1 have reviewed the solar energy system installation in the subject topic on 10/19/2019. The units have been installed in accordance with the manufacturer's installation instructions and the construction drawings approved by the Town of Southold. The solar panel installation is in compliance with the requirements of the 2015 International Residential Code, the 2017 NYS Supplement to the Uniform Code, ASCE 07-10 and NFPA Standard 70 "National Electrical Code." Markings in accordance with Section 690.53 of the National Electrical Code are provided. To my best belief and knowledge, the work in this document is accurate, conforms to the governing codes and standards applicable at the time of submission, and conforms with reasonable standards of practice with the view to the safeguarding of life,health, property and public welfare. Sincerely, Luigi Claudio Sciandra Professional Engineer 1 OF NEW f-O Co �v`G,G SClgNO�9�r 060935� AROFESSIONP� FIELD INSPECTION REPORT DATE COMMENTS b FOUNDATION(IST) Z H ------------------------------------ FOUNDATION (2ND) , o ROUGH FRAMING& o , PLUMBING y INSULATION PER N.Y. y STATE ENERGY CODE FINAL ADDITIONAL COMMENTS 0 1111111 �m r �5 \ y O z ty� x e TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 _ Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C.- Trustees C.O.Application Flood Permit Examined 20 Single&Separate Truss Identification Form / Storm-Water Assessment Form -7C Contact: Approved ,20 Mail'to: V0- � ��ti ` eerg Disapproved a/c M ;*" k ; �u����\�o r, 5 Z Phone: (--31-279- 7,713 2 7 ou p Expiration i - ``� j r•�-`r����='�-t;' (J=,r--, y'1'O S "aL- ate'• IT�' i••1 4 I �f 1�y L..' / ' g nspector SEP 1 2 2019 APPLICATION FOR BUILDING PERMIT Date a , 20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12-months after the date of issuance or has not been completed,within18 months•from such date.If no•zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter,a new,permit shall be required. APPLICATION IS HEREBY MADE,to the-Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing,code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) Eleme►,A- -"e_dto L_L.c° 7 V 70 Sorg.nd ISL u e ,o1ac'(f•,+dce k 4N Y 119 S1, (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises !" (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer 'lei ^a e( Law-6%,, . Pr e S%de o- (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License Not. ' SZ L&g - M C Other 1. LI cation`;of-l`arid�n"wfiicli,proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section 1 ZT 00 Block 0(o•OD Lot 010 .CXR D v uVul YLJ1VLL 1'l1GLL lV10.�J 1V V. LUl �' `--\ 1 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy Q e s i d ent ur 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work' Sn la.- SInA-a\,nct o n (Description) 4. Estimated Cost Fee 4 2CC) (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor " If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing'structures, if any: Front Rear Depth Height Number of Stories Dimensions of-same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories' 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO -t,, t WJ-Uj i(CPO 14. Names of Owner of premises F(I K Lg 6, Address Rem til aktiyf)�) Phone No. Name of Architect Address Phone No Name of Contractor(I-et-fnem�, Address 7476 :&au ,d 14ue- Phone No.�1-119- 791r 3 Pia-FF►tue.K ,W%k I) SA 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES°&D.E.C:'PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. l6. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO I� * IF YES, PROVIDE A COPY.` DATE OF NEW YORK) SS: :OUNTY OF -:5 0P-1 L being duly sworn;deposes-arid7"says-that(s)iie is the applicant- (Name of individual signing contract)-above named, S)He is the e 6 n+rac'4--a P- / Ag ie n* (Contractor,Agent, Corporate Officer,etc.) ,f said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; zat all statements contained in this application are true to the best of his knowledge and.belief; an��bpAvlq ,wiI be ,erformed in the manner set forth in the application filed therewith. NOTARY PUBLIC-STATE OF NEW YORK No. O1 MA4676634 worn to before me this Qualified In Suffolk County day of 20_LL My Commission Explres March 30, 20 9-�2' Paz�.c.J_0 615e4l,- Notary Public Signature of Applicant BUILDING DEPARTMENT-Electrical Inspector W. TOWN OF SOUTHOLD '. Town Hall Annex=54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 _.: AMLXON-F�ELECTRLCAL INSPECTION REQUESTED BY: �. _ _ _ _-- -- Date::, . j a Company Name: - _ NEC Name: - -- - email: License No.: _ _E32&,g - � - -- - - ---_ Phone No:: =C¢-3f-_��4-'? 9q — - -- -_--- JOB SITE INFORMATION: (All Information Required) — ` - Address: -- - - - - I - ---- --_---- --- D. __-- -- Cross Street: _ _ - - 2 J Phone No.: - - ----- email: -�{:----_- - a - - - District:- _ 1000_ Section: /2 Block___ Lot:° _(D BRIEF DESCRIPTION OF WORK(Please Print Clearly) Circle All That Apply: Is job ready for inspection?: YES NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: - (All information required) 800%.,Size 1 Ph 3 Ph Size:,.._ __ _ __A #Meters __ Old Meter# New Service-- Fire Reconnect- Flood Reconnect- Service Reconnected -Underground -Overhead Undehhund_Laterals _1 2 H Frame Pole Work.done_on_Service?___ _Y N-_ _ Additional Informationo _2.b VU �c�f1�iS� 70Cl =GiS � En �\ � 0sn - - - - NYVIVIENT_DUEWITH APPLICATION 82-Request for Inspection FormAs 00 1 oF so�P�®� Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 ® �� lycouff",� BUILDING DEPARTMENT TOWN OF SOUTHOLD December 10, 2019 Element Energy 7470 Sound Ave Mattituck NY 11952 Re: Kubetz, 1600 N. Oakwood Dr, Laurel TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: f Note:Need-Engineer'-s-Certificafion_letter stating-thepanels were'installed-to•the-roof per N S' �Building Code �� � Electrical Underwriters Certificate A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 411/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT —44178 - Solar A�"��� DATE�MIDOIYYYYy I�,•��`�..��"� CERTIFICATE OF LIABILITY INSURANCE 71�s12o,9 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the pollcyges)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the tarms and conditions of the policy,cartaln policies may require an endorsement A statement on this certHicate does not confer rIAhts to the certificate holder In lieu of such endoreement(s). PRODUCER ROBERT S.FERE INSURANCE AGENCY PH E F►x11136 23 GREEN STREET,SUITE 102 MAL. HUNTINGTON,NY 11743 A R ROBERT S. FERE INSURANCEINSURER S AFFORtwYG COVERAGE NAIc a INSURER A• INSURED INSURER 0:STATE INSURANCE FUNU- Element Energy LLC INSURERC: ELEMENT ENERGY SYSTEMS INSURERD: 7470 SOUND AVENUE INSURER E: MATTITUCK, NY 11952 _ INSURER F COVERAGES CERTIFICATE NUMBER; REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIM& ITRADDLR TYPE OF INSURANCE am SUB LTPOLICY NUMBER IM j CY MM mp�jypy�y LMTS COMMERCIAL GENERAL UABIUTY C�LOO275204 EACH OCCURRENCE $ 11000,000 X X 7/1412019 7194/2020 CLAIMS-MADE El OCCUR PREM aamumnce $ 100=0 A MED EXP OM onpaym 1 5000 PERSONAL R ADV INJURY E 1000000 M'OTHER LAGGREGATELIMITAPPLIESPERGENERALAGGREGATE E 2,0W,000POLICY ElEC ❑LOCPRODUCT$-COMPIOPAGG a Z,OOO,aoo L AUTOMOBILE LIABILITY COMBINED SINGLE OMIT C0 aocideuq ANY AUTO tFpUar ILY INJURY(Por ppr$on) g OWNED SCHEDULED AUTOS ONLY AUTOS ILYINARY(Persoddany 5 HIRED NOM-OWNED PERTYDANAC,E AUTOS ONLY AUTOS ONLY i s X UMBRELLA UAB X OCCUR XL00011240 7/14/2019 7/14/2020 EACH OCCURRENCE s 1, ,000 61tCf55 UAB � CLAIMS-MADE AGGREGATE i QED RETENTIONS S /!YORKERS COMPENSATION AND EMPLOYERS!LIABILITY YIN 124494445 X PEAT EH- OFFICERIMEMBEREXXC UDED?ECUTNE a N!A X 7/1412419 7114/2020 E.L.EACH ACCIDENT s 1,000,000 (Mandatory In NH) I<pas deaciib$under E.L.DISEASE.EA EMPLO SI_000000 DESGIR PTION OF OPERATIONS below E.L DISEASE.POLICY LIMIT 3 1 Ono-can NY State Disability 10279340 711412019 711412020 statutory DESCRIPTION OFOPERATIONIS I LOCATIONS I VEHICLES(ACORD 101,AddMonal Remarks Scheduia,maybe at"ched 11 mon$pact Is required) CERTIFICATE HOLDER LISTED IS AN ADDITIONAL ENSURED CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 54375 Main Road THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Southold,NY 11971 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORISED REPRESENTATIVE ftbert'S. Fede, Sr, CORD 25(2016103) The+4CORD items and 1000 are ®1988-M 6 ACORD CORPORATION. All rights reserved, g registered marks of ACORD New York State Insurance Fund Workers'Compensation&Disability$enefits SpediWlsts Smee 1914 8 CORPORATE CENTER DR,3RD FLR,MELVILLE,NEW YORK 11747-3128 CERTIFICATE OF WORKERS' COMPENSATION INSURANCE (RENEWED) a WE A A A A A A 823336604 ROBERT S FEDE INSURANCE AGENCY 23 GREEN ST STE 1022 HUNTINGTON NY 11743 0 . SCAM TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER ELEMENT ENERGY LLC TOWN OF SOUTHOLD DBA ELEMENT ENERGY SYSTEMS 54375 MAIN ROAD 7470 SOUND AVENUE SOUTHOLD NY 11971 MATTITUCK NY 11952 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE 12449444-5 131560 07113/2019 TO 07/13/2020 7/24/2019 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NOS 2449 444-5, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:WMW.NYSIF.COMICERTiCERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND 15 NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS POLICY DOES NOT COVER THE SOLE PROPRIETOR,PARTNERS ANDIOR MEMBERS OF A LIMITED LIABILITY COMPANY. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE: HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK,STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:719279724 U-28.3 LUIGI CLAUDIO SCIANDPA, P.E. 5 Wesleyan Court• Smithtown, NY 11787-3011 • (631)543-2953 •fax(631)543-1526 E-mail:Ics4d@aol.com Friday, September 06, 2019 COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES Element Energy Systems AS REQUIRED A 7470 Sound Avenue SnLI Mattituck, New York 11952 E9F INGBOAID Tel. 631-779-4004 EES Attn.: Mr. Mike Lawton, Principal mato"100140 Re: Forty(40) 315 W PV Roof Top Eeemcm' Solar Panel Array, 12.6 kW DC Total Output, for Kubetz Residence, 1600 North Oakwood Road, Laurel, New York 11948 Dear Mr. Lawton: Pursuant to your request, I have reviewed the following information regarding the subject roof top solar panel array: • Cover Sheet with Site Visit/Verification prepared by E2Sys representative identifying specific site information including size and spacing of roof supporting element for the existing roof of the proposed system to include cover sheet, site plan, mounting and structural details. This information was prepared by E2Sys and will be utilized for approval by the Town of Southold and for construction of the proposed system. Based on the above documentation, I have evaluated the structural capacity of the existing system to support the additional loads described below, imposed by the solar panel arrays and offer the following comments. The existing roof types are as follows: Residence Roof, Arrays 1, 2: 5/8" plywood decking, QAP..'101�I0 AS NOTE2"x10" at 16" on center Douglas Fir rafters, B P # 0 i 2"x8" Douglas Fir ceiling joists at 16" on center, DATE: 2"x6" Douglas Fir collar ties at 32" on center, FEE:Roof pitch 27°. NO it Y BUILDING DF'I i Iti�ENT AT 765-1802 8 AIM TO 4 PM FOR THE FOLLOWING INSPECTI:�i,lS: Detached Garage Roof, Array 3: 1. FOUNDATION - TWO REQUIRED 3/4" tongue and groove decking, FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 2"x8" at 16" on center Douglas Fir rafters, 3. INSULATION 2"x6" Douglas F'r ceiq,,R7sbp 16" on center, 4. FINAL - CONSTRUCTION MUST , ° BE COMPLETE FOR C.O. �� � UNLAWFUL ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW 1 �b0�T CERTIFICATE DESIGN ORYORK ECONSITRUCTONSIBLE FOR ERRORS. F OCCUPANCY 2"x4" Douglas Fir collar ties at 48" on center, Roof pitch 34°. Structural Analysis: The structural analysis has been carried out using the following design criteria: Design wind speed: 130 mph Ground snow load: 20 lbs/sq. ft. Solar Arrays 1, 2 Dead Load: 2.7 lbs/sq. ft. Solar Array 3 Dead Load: 2.8 lbs/sq. ft. Total Unit Weight of Array 1: 543.3 lbs Total Unit Weight of Array 2: 734.1 lbs Total Unit Weight of Array 3: 707.3 lbs The above values are within acceptable limits of recognized industry standards for similar structures.The structural analysis, performed for the existing structure and for the solar panel arrays, utilizing the above design loads, indicates that the existing roofs will be able to support the additional panel weight without damage, if installed correctly. The onsite inspection and the photographs show that the roof framing is in good conditions. However, the building owners are to be made aware that long term build up of heavy snow conditions may produce deflections in the roof structure. If any deflection is noticed, than it is recommended that the solar panels be cleared of accumulated snow more than one(1)foot deep over a period of one week. If no deflections are visible under any snow loading over a period of time, then there is no need to clear the solar panels. Based on the above evaluation, it is the opinion of the undersigned professional engineer, that with appropriate solar panel anchors being utilized, the roof system will adequately support the additional loading imposed by the solar panel arrays.This evaluation is in conformance with the 2015 International Building Code,the 2017 NYS Supplement to the Uniform Code, SEI/ASCE 7-10"Minimum Design Loads for Buildings and Other Structures", 2014 NFPA Standard 70 "National Electrical Code", current industry standards and practice and based on documentation and data supplied by E2Sys at the time of this report. Should you have any questions regarding the above or if you require additional information, do not hesitate to contact me. Sincerely, L gi Claudio Sciandra, P. E. of NEW yo ScigN�p�t v "4 060935' AROFESSI0140' 2 SCOPE OF WORK ENA:BC 4 DRAFTIN,�� IE MINNICK \ TO INSTALL A 12.6 kW SOLAP.PHOTOVOLTAIC(PV)SYSTEM AT THE KUBETZ RESIDENCE, EP CERTIFIED LOCATED AT 1600 NORTH OAKWOOD ROAD, LAUREL, NY 1 1948. 1 112-129 THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. + . THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. �� f REVISIONS DESCRIPTION DATE REV SYSTEM RATING �S `` ORIGINAL 05-23.2019 12.G kW DC STC ��=• �� EQUIPMENT SUMMARY 40 QCELL5 Q.PEAK DUO 5LK-G5 315 PV MODULES (� ;� , —- �`T /f 40 ENPHA5E I07-GO-2-U5 MICRO INVERTERS' I IRONRIDGE XR100 MOUNTING SYSTEM r ;_ CONTRACTOR SHEET INDEX ,)= ELEMENT ENERGY, LLC. Pv-I COVER > d` , 7470 SOUND AVE PV-2 SITE PLAN may, = .� X MATTITUCK, NY 1 195 PV-3 ROOF PV LAYOUT t` ��� d ' LICENSE # 43889-H PV-4 STRUCTURAL/DETAILS 4 SECTIONS ��- ?=• ri / r LICENSE # 52G89-ME PV-5 3-LINE ELECTRICAL DIAGRAM •�i+ p _ .--5 -- GOVERNING CODES � •ate- - ,-°�R 2014 NATIONAL ELECTRICAL CODE, "M __ .' , �1 _1.0—n.,.,•� - _ PROJECT NAME 2015 INTERNATIONAL RESIDENTIAL CODE AND NYS 2017 SUPPLEMENT. UNDERWRITERS LABORATORIE5(UL)STANDARDS 05HA29CFR 1910.269 PROJECT LOCATION Q U CO GENERAL NOTES d- 1. CONTRACTOR SHALL CHECK AND VERIFY ALL CONDITIONS AT .'3j LLJ O THE SITE PRIOR TO STARTING TO WORK AND SHALL FAMILIARIZE HIMSELF WITH THE INTENT OF THESE PLANS AND MAKE WORK T O AGREE THE SAME. a iLLJ 2. CONTRACTOR OR OWNER SHALL OBTAIN ALL REQUIRED Q APPROVALS, PERMITS, CERTIFICATES OF OCCUPANCY, " ••f,t' , INSPECTION APPROVALS, t—fC 0. CONTRACTOR TO EFFECT AND MAINTAIN INSURANCE, I.E. FOR WORK PERFORMED FROM O W AGENCIES HAVING JURISDICTION THEREOF, IF REQUIRED. CONTRACTOR'S LIABILITY, WORKMAN'S COMPENSATION, r �-- 3. ALL WORK SHALL CONFORM TO CONSTRUCTION CODE AND COMPLETED OPERATION, ETC. ADEQUATE FOR THE PURPOSES Lu SAME PRIOR TO 3+ =`' ;r�' #: r Rr�k- ALL RULES AND REGULATIONS OF THE RESPONSIBLE OF TH15 PROJECT AND FURNISH PROOF OF '� co z � COMMENCING WITH WORK. JURISDICTION, EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR 4. IF IN THE COURSE OF CONSTRUCTION A CONDITION EXISTS I I, �a,r,., `- •,.�"� x a;at:v MAINTAINING SAFETY ON THE JOB SITE DURING THE WHICH D15AGREE5 WITH THAT AS INDICATED ON THESE PLANS, , �s;,t,..•• �. "' �' eq CONSTRUCTION PHASETO COMPLY WITH THE REGULATIONS THE CONTRACTOR SHALL STOP WORK AND NOTIFY THE AND REQUIREMENTS OF THE OCCUPATIONAL SAFETY AND '•- •= �,. ENGINEER, SHOULD HE FAIL TO FOLLOW THIS PROCEDURE AND h'`,,, _ ,,'•}'�.r;� � , _ —' HEALTH ADMINISTRATION.TH15 SHALL INCLUDE, BUT ARE NOT `� 7 .� r CONTINUE WITH THE WORK, HE SHALL A55UME ALL „,,,,t„ , LIMITED TO: PROVIDING FOR ADEQUATE AND PROPER BRACING, �• } ?` it ,..y•,,,, RESPON5181LITY AND LIABILITY THEREFROM •,(t� ;n;•�:� tt ,:,;� ; - Y SAFETY RAILINGS AND SECURE FOOTINGS FOR ALL TEMPORARY o ? ;.,' '' 5HEET NAME 5, ALL STRUCTURAL STEEL SHALL BE A-36 AND SHALL BE 4 f i' ., r 3, Y ' FABRICATED AND INSTALLED AS PER LATEST A.1.5.0 SCAFFOLDING, STAIRS, ETC— AS WELL AS PERMANENT 1`•.` - `�M��" SPECIFICATIONS. CONSTRUCTION. .; ''r"">`�'��'.�� ' s,.,Y`L;�,';��,�°., &�'•,� r,rr4 b . s• �n.`N ��vN . I - COVER 12, FIGURED DIMENSIONS SHALL GOVERN. DO NOT SCALEa G. ALL ELECTRICAL WORK SHALL BE BOARD OF FIRE 'w UNDERWRITERS APPROVED AND IN ACCORDANCE WITH N.E.C. DRAWINGS, WHERE DIMENSIONS ARE ESTABLISHED BY EXISTING k `+a`t, ng'`��' ' � NYS CODES 4 REGULATIONS CONDITIONS. EACH CONTRACTOR SHALL VERIFY EXISTING �.��;•5 7. ANY DEVIATION FROM THESE PLANS WITHOUT THE WRITTEN ONDITIONS PRIOR TO ORDERING MATERIALS AND "fin • CONSENT OF THE ENGINEER WILL NEGATE THE ENGINEER'S COMMENCING WITH WORK. CERTIFICATION OF THESE PLANS. 13. CONTRACTOR TO REMOVE ALL DEBRIS CREATED BY TH15 :r DRAWING SCALE G WORK FROM THE 51TE AND DISPOSE OF IN A LEGAL MANNER ON " 8, THESE DRAWINGS AS INSTRUCMENTS OF SERVICE ARE AND N I .T.5. SHALL REMAIN THE PROPERTY OF THE ENGINEER WHETHER THE A WEEKLY BASIS OR SOONER IF CONDITIONS WARRANT, I V PROJECT FOR WHICH THEY ARE MADE I5 EXECUTED OR NOT. 14. AT THE COMPLETION OF WORK,THE SITE TO BE CLEARED THEY ARE NOT TO BE USED ON ANY OTHER PROJECTS OR OF ALL DEBRIS AND EXCESS MATERIALS.THE FACILITY 15 TO BE EXTENSIONS TO THIS PROJECT • LEFT BROOM CLEAN AND WORK 15 TO BE COMPLETED TO THE 9. CONTRACTOR SHALL PROTECT, PATCH AND REPAIR ALL TOTAL SATISFACTION OF THE OWNER PRIOR TO RELEASE OF SHEET NUMBER EXISTING WORK ADJACENT TO HIS WORK, OR DAMAGED AS FINAL PAYMENT. d RESULT OF HI5 WORK. I AERIAL VIEW PV- I ,r i 4 1�1 CONSTRUCTION NOTE5 ` DESIGN k DRAPTINGr , 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE JAMIE MINNICK �\ MANUFACTURER'S IN5TALLATION INSTRUCTIONS. �• NA RTIFIED 2,)ALL OUTDOOR EQUIPMENT SHALL 5E RAINTIGHT WITH MINIMUM NEMA 3R RATING. I a m o5511111122-129 N 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. " REV15ION5 DESCRIPTION DATE REV Y ORIGINAL 08.23-2019 00 — —_— _ 30'--- ---- ------ 0o goo 270o 0 70 190. 7,C90. SDo 0. CONTRACTOR r 36"x 30GROUND ACCE5 TYP. �'-'""-"I ELEMENT ENERGY, LLC. 7470 SOUND AVE MATTITUCK, NY 1195 LICENSE # 43889-H LICENSE # 52G89-ME I ' u,. ��r� ,,,q ���� `7•r?�j PROJQNAME Q i W 0 00 W Q O v 18'PIPE 5GTHAGK®RIDGE Lu N o J I— U-i Lu cz LEGEND &Z O � rn �$e / TY METER MAIN SERVICE PANEL PAN -- ' I NEW PV SUB-PANELS — 1 A/0 DISCONNECT �1 COABINER INVERTERS SHEET NAME ® GND ELECTRODE -�- - - PV MODULE SITE PLAN I RACKING RAIL 0 ATTACHMENT POINT 4' _.�i 2'-92' ---RAFTERS -4-ROOF PITCH ANGLE DRAWING SCALE �SUNRUN METER ®VENT N .T.S. 0PLUMBING VENT ®SKY LIGHT ®CHIMNEY SHEET NUMBER GOOD SHINGLES ° OU DACC 5 PV-2 jTRIM/REMOVE ASNECESSARY - 1, DETACHED GARAGE ENABCEP N*DRAFTING BY: CONSTRUCTION SUMMARY `� ! MIEMINNICK (40) QCELL5 Q,PEAK DUO BLK-G5 315 WATT PV MODULES ARRAY#3 CERTIFIED (40) ENPHASE IW-GO-2-U5 MICRO INVERTERS n 14 MODULES (70)ATTACHMENT POINTS @ G4"OC MAX. " 30*PITCH n (289.4) LF IRONRIDGE XR100 MOUNTING SYSTEM. N 148°AZIMUTH ; REV15ION5 ROOF TYPE = ASPHALT SHINGLE-`J'INGLE LAYER(TYPICAL) a DESCRIPTION DATE REV 0MGINAL 08-23-2019 CONSTRUCTION NOTES 1.)ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE I I 13n_ _ ,- - - - WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 'I r 2,)ALL OUTDOOR EQUIPMENT SHALL BE RA(NTIGHT WITH MINIMUM NEMA 3R RATING. 3.)ALL LOCATIONS ARE APPROXIMATE AND REQUIRE 111 I i FIELD VERIFICATION. - 2 L'-•i�_J 7- __�r�i I I L - `moi _ ! - _ I!_l �J CONTRACTOR i ELEMENT ENERGY, LLC. 3G"x 3G"GROUND ACCESS TYP. - - 7470 SOUND AVE MATTITUCK, NY 1 195 - LICENSE #43889-H LICENSE # 52G89-ME l , i I 4 PROJECT NAME 1 47 � Q '� Q avb Lu 0 CO N NOTE, N �f �° �5b®�✓ d,• U l rt- m y &SPACING BETWEEN PV MODULES TYP. ` K �� z Q DIMENSIONS ARE FROM EDGE OF PV MODULES Y LLJ O TO EDGE OF METAL ROOF TYP. N I ARRAY#I ARRAY#2 I I MODULES 15 MODULESI n 27°PITCH 27°PITCH 8° { 14AZIMUTH 148°AZIMUTH 0 Lu h t� • ,. �18°FIRE SETBACK,@ RIDGE ,- -� �"" LU 1 I I , o DOSTING UTILITY METH lL�_r1-17 T - --_— _I _� ®MAIN SERVICE PANEL _ ®NA/P ISUB-PANELS SCONNECT 1 _ +�� 9991NER INVER705 5HEET NAME ® GND ELECTRODE f I i mlPV MODULE �� y , m ROOF DETAIL I _.� _I .; '��j i 9ct - '\ �RACIONG RAIL L G�Q 9cC�n 0 ATTACHMENT POINT 11 _ I ��,OP S ,� oN ---RAFTERS 9 t!1 8 - � 1,'� i1 -Su Go O 4-ROOF PITCH ANGLE DRAWING 5CALE 4/ ®SUNRUN METER N .T.S.. . / \ Oo Q OPLUMBING VENT I '-✓"� I I I -070o 0 ' 900 ®SKY LIGHT I_-�� I I ✓ 80 o 7S00 2Qo c ®CHIMNEY 5HEET NUMBER 1• S, ®COMPOSITE SHINGLESGOOD CONDITION PV-3 I POTENTIAL SHADING ISSUES TRIM/REMOVE AS NECESSARY LOAD CALCULATIONS ARRAY#I ARRAY#2 ARRAY#3 ITEM DESCRIPTION ARRAY#I * 2 ARRAY#3 DE51GN 4 DRAFTING BY. odule Weieht 41.2 Lbs 41.2 Lbs 41.2 Lbs Rafter 2"x 10"D-FIR 1 G"O.C. 2"x 8" D-FIR I G"O.C. JAMIE MINNICK Of MQd1JI05 1 1 15 14 (D) Decking 5/8" PLYWOOD 3/4"TOUNGE�GROOVE NABCEP CERTIFIED Total Module Wel ht 453.2 Lbs G 18 Lbs 576.8 Lbs (C) Collar Ties 2"x G"D-FIR @32"O.C. 2"x 4" D-FIR @48"O.C. 051112-129 Total Len th of Rail 73.7 Ft 100.2 Ft 1 15.5 Ft (K) Knee Wall 2"x G"D-FIR @ I G"O.C. N/A o Rail Wei ht per Foot 0.G8 Lbs 0.G8 Lbs O.G8 Lbs (J) Ceilincl Joist 2"x 8" D-FIR @ I G"O.C. 2"x G" D-FIR @ I G"O.C. REV151ON5 Total Rail Wel ht 50 1 Lbs G8.I Lbs 78.5 Lbs (P) Pitch 27° 34° De5cmmoN DATE REv #of Standoffs 20 24 2GRL a B oa a 2"x 12"D-FIR 2"x 10"D-FIR OPIGINAL 08-23.2019 r� r-j- � Y Wei ht per standoff 2 Lbs 2 Lbs 2 Lbs '�,, �, c�9,0 � �y (H) Span Width of Rafter(R) 120"MAX-Achieved with Load Bearing 9G"MAX ' Total Standoff Wel ht 40 Lbs 48 Lbs 52 LbsoQ w �. Wall Knee Wall in Attic Total Array Wei ht 543.3 Lbs 734.1 Lbs 707.3 Lbs Point Load 27.2 Lbs 30.G Lb5l 27.2 Lbs ` ,^_ , (R) (RB) Total Array Area 200.7 5A Ft 273.8 5ci Ft 255.4 5ci Ft k` � FArray Dead Load 2.7 Lbs/5 Ft 2.7 Lbs/50 Ft 2.8 Lbs 5 Ft `, +- J (D) L.•' ..w."'.On'Y d r d E:����' s ✓' CONTRACTOR ( ) ELEMENT ENERGY, LLC. As per ASCE 7- Method I: i G-2 7470 SOUND AVE e - „���'�r P net = Kzt Pnet30 e - t(sec G.5.7) I ne e - # !�� � (K) (C) MATTITUCK, NY 1 1 95 LICENSE# 43889-H CLIMACTIC AND Ground Ind Spee Live load, Point Max fastener LICENSE# 52@89-ME GEOGRAPHIC DESIGN Category Snow Load 3 sec gust pnet30 pe pullout loa Fastener Type spacing along CRITERIA Pg mph A5CE7, psi Ib. rails, in. A # 20 130 # 4G8 5/1 G"x G"Stainless Steel 64„ Roof Section B # TYP. TYP. # TYP. Lag Bolts (H # PROJECT NAME (J) For SI:1 pound per square foot=0.0479 kPa,1 mile per hour=0.447 m/s. LOAD BEARING WALL C)Q a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural O requirements of this code.The weathering column shall be filled in with the weathering index,"negligible,""moderate"or"severe"for concrete as 00 determined from Figure R301.2(3).The grade of masonry units shall be determined from ASTM C 34,C 55,C 62,C 73,C 90,C 129,C 145,C 216 U �- or C 652. z Q b. The frost line depth may require deeper footings than Indicated In Figure R403.1(1).The Jurisdiction shall fill in the frost line depth column with LLJ _ the minimum depth of footing below finish grade. ROOF FRAMING DETAIL n O C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local O - subterranean termite damage. \ d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map[Figure R301.2(4)A].Wind exposure LLJj category shall be determined on a site-specific basis in accordance with Section R301.2.1.4. z e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the Q International Plumbing Code.Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience MODULE MOUNTING CLAMP N as determined by the building official. �~ - O LLJ f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. SOLAR MODULE � �''� rr,_ ="� LU CZ g. To establish flood hazard areas,each community regulated under Title 19,Part 1203 of the Official Compilation of Codes,Rules and STAINLESS STEEL 3/8" Regulations of the State of New York(NYCRR)shall adopt a flood hazard map and supporting data.The flood hazard map shall include,at a -' BOLT AND NUT O C) special flood hazard areas as identified by the Federal Emergency Management Agency In the Flood Insurance Study for the community, �'^~ -� as amended or revised with: s'' i.The accompanying Flood Insurance Rate Map(FIRM), RONRIDGE ALUMINUM RAIL ii.Flood Boundary and Floodway Map(FBFM),and I - 111.Related supporting data along with any revisions thereto. ' ALUMINUM"L°BRACKET The adopted flood hazard map and supporting data are hereby adopted by reference and declared to be part of this section. h. In accordance with Sections R905.1.2,8905.4.3.1,R905.5.3.1,R905.6.3.1,R905.7.3.1 and R905.8.3.1,where there has been a history of ALUMINUM PLA511ING SHEET NAME local damage from the effects of ice damming,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall fill in this part of the table with"NO." ST RU CT U RA L i. The Jurisdiction shall fill in this part of the table with the 100-year return period air freezing Index(BF-days)from Figure 8403.3(2)or from the 100-year(99 percent)value on the National Climatic Data Center data table"Air Freezing Index-USA Method(Base 32°F)." ASPHALT SHINGLE ROOF J. The jurisdiction shall fill In this part of the table with the mean annual temperature from the National Climatic Data Center data table"Air 5/1 0x 0 STAINLESS STEEL LAG BOLT WITH Freezing Index-USA Method(Base 32°F):' STEEL 1/2'MIN THREAD k. In accordance with Section R301.2.1.5,where there Is local historical data documenting structural damage to buildings due to topographic wind PENETRATION SEALED DRAWING SCALE speed-up effects,the jurisdiction shall fill in this part of the table with"YES."Otherwise,the jurisdiction shall indicate"NO"in this part of the table. WITH GEOCEL 4500 1. In accordance with Figure R301.2(4)A,where there is local historical data documenting unusual wind conditions,the jurisdiction shall fill in this (EQUIVALENT OR BETTER) part of the table with"YES"and AS NOTED m. in accordance with Section R301.2.1.2.1,the jurisdiction shall Indicate the wind-borne debris wind zone(s).Otherwise,the jurisdiction shall Indicate"NO"in this part of the table. n. The ground snow loads to be used In determining the design snow loads for roofs are given in Figure R301.2(5)for sites at elevations up to 1000 feet.Sites and elevations above 1000 feet shall have their ground snow load increased from the mapped value by 2 Ibs/ft2 for every 100 feet SHEET NUMBER above 1000 feet. //�� (") See Figure R301.2(4)B. PV-`-i" MOUNTING DETAIL n 50LAR ARRAY(12 6 kW) (iU)UCCLLS U FCAI^JLU A'J C5 S I B N MGUV117 OLAR MODULE TYP, DESIGN 4 DRAFTING BY: (N 9141\GOO G),VWD)IVC5S1`,(N 4CDUL.CM(I JI�i'�1'-0Ih^/tFitK,1(Ili•T?11:�1OV(10)P'ICNO'1Jt KtEP9 MINNIC STRING N I __ _ +� = 1�= (^� _ _ _� u = CERTIFIED JAMIE C I I NABCEP CERTIFIED 0 051112-129 --I `— �----� _—JI — — REVISIONS }— ------------------------{c _ _ __- T—_1---0 ~ —Q �_ °Q•-- �T -�I �----p�-- DE5CRIPTION DATE REV 1 —-- ----- `---- `-- ----� --- --- --- --- `-- I — — — — — — — — — _ — — — — — ORIGINAL 08.23-2019 STRING#2 I I TO UTILITY GRID — — — — — Q-- - _ ---- _-- --- ----- --- - --- Q— ��---�G L UTILITY METER f1-PHASE,240 V 1 2 STRING#3 N= I i 1 1 r— -- — — _ — _ — 1 — CONTRACTOR 1 I — ' MICROINVERW ELEMENT ENERGY, LLC, 1 I ENPHASE BRANCH + 2 N I CIRCUIT CABLE TIP. ENPHA5E 107.60.2-1.15 AC DI5CONNECf 240 VAC.1.0 A— FER IJtOCE240,2C(B)(t)1TC90,G I(A) 7470 SOUND AVE I 1 i I 1 1 97m CtC-WEIGHTED Lfr 50 D D223NR5 LL?IGTH Or TAr GONDU:TOGS I �' 5HAIL NOT MCEED I OPT 1 NCMAG,ULL15TCO (� ,; N[MA3,(;0A(ED MATTITUCK, NY 1 195 i NeVA31,ULU LICENSE #43889—H AC COMBINER BOX �. _ 61AN 5CRV(Cr DISCONNECT V,200 A I "A * LICENSE # 52689—ME'3)a.Put c nrtrnrte5,a..w v,ao nL I La( N L LI2+oa Ti0A -------- ____ ___-- 01 - 22PROJECT NAME --J iC" g I ' L1 Lt �9 z 2 0 MAIN SERVICE PANEL W n/ G N 1 2 ::n. '� I I P40VAC I I -ODA z I I I N W O _ I I I I I O I FX15TING GROUNDING - ELECTRODE SYSTEM ----------------------------------------------- - ----------------------------------------------� L-------------) ; W > z WIRE CONDUIT SCHEDULE (v O W CIRCUIT CIRCUIT CIRCUIT CONDUCTOR CONDUCTORS CONDUCTOR CONDUIT FILL CONDUCTOR GROUND GROUND GROUND TYPE CONDUIT CONDUIT AMBIENT TEMP ESTIMATED Voltage Drop(%a W R/ I.D.# ORIGIN DESTINATION SIZE PER POLE QUANTITY DERATE INSULATION SIZE QUANTITY INSULATION (CU/AL) TYPE SIZE TEMP DERATE DISTANCE 310.15(5)(3) 310,15(5)(2oV(3c) CD z STRING INVERTER AWG#10 1 G 0.8 U5E-2/PV Wire AWG#8 1 BARE CU FREE AIR P, 700C 0.65 I I OFT 0.8% O Q OR EMT O INVERTER COMBINER PANEL AWG#G 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I,, 459C 0.87 25 FT O.G% COMBINER MAIN PANEL AWG#G 1 1 3 1 THWN-2 AWG#8 1 THWN-2 CU PVC I" 45PC 0.87 1 O FT O.G% ELECTRICAL NOTES SHEET NAME 1.)ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION, CALCULATIONS FOR CURRENT CARRYING CONDUCTORS F 2.)ALL CONDUCTORS SHALL BE COPPER,RATED FOR GOO V AND 909C WET ENVIRONMENT. —LINE DIA. 3.)WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY #I PV Source Circuit Wire Ampaclty Calculation CONFIGURATION TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. [NEC G90.8(B)(I)]) (I5c)'(#of 5tring5)'(1.56)= 20 A Modules per Str1n 16, 14, I 0 4.)WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL AWG#10,ampac)ty'Temp Derate'Conduit FIII Derate= 20.8 A 20.8 A>20 A,therefore DC wire size 1s valid. Modules per Inverter I COMPLY WITH NEC I I O.Z6. ' 5.)DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL Number of Inverters 40 FURNISH ALL NECE55ARY OUTLETS,SUPPORTS, FITTING5 AND ACE550RIE5 TO FULFILL #2 Combined Inverter Output Wire Ampaclty Calculation Record low tem -109C Inverter Output Circuit OCP Calculation(Inverter Imp)'(I.25) = 50 A DRAWING SCALE APPLICABLE CODES AND STANDARDS. AWG#6,derated ampacity'(Temp Derate)'(Conduit FIII Derate) =G5,25 A Voc Temp Coefficient -0.28%/QC G.)WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, THE CON TRACTOR SHALL SIZE TI1EM ACCORDINGLY. 65.25 A> 50 A,therefore AC wire size is valid. DC SYSTEM SPECIFICATIONS CALCULATIONS N .T.5. 7)ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. Operatinia Current 9.4 A =(#of 5trin s)'(lm ) 8.)MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE #3 Combined Inverter Output Wire Ampaclty Calculation Operating Voltage 33 G V =(#modules to 5erie5)'(Vm ) SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. Inverter Output Circuit OCP Calculation(Inverter Imp)'(],25) = 50 A Max,System Voltage 44,2 V = (#modules in series)'((((-#.##%V/QC'.01)'(Lo Temp##QC-25))'(Voc))+(Voc)) 9.)MODULE SUPPORT PAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEER LUG AWG#6,derated an)paclty'(Temp Derate)'(Conduit F111 Derate)= G5.25 A OR IL5C0 GBL-4DBT LAY-IN LUG 65.25 A> 50 A therefore AC wire size is valid. Short Circuit Current 12.4 A =(#of stnngs)'(Isc)'(I.25)per ArL. G90.8(A)(1) SHEET NUMBER 10.)THE POLARITY OF THE GROUNDED CONDUCTORS 15(po5itive/negative) AC SYSTEM SPECIFICATIONS r ` ,— OR Max AC Output Current 50 A r v 10.)THE DC SIDE OF THE PV SYSTEM 15 UNGROUNDED AND SHALL COMPLY WITH NEC G90 35 O eratin AC Volta e 240 V