Loading...
HomeMy WebLinkAbout44676-Z Town of Southold 3/13/2020 0 P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41135 Date: 3/13/2020 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 1110 Tuthill Rd Ext, Southold SCTM#: 473889 Sec/Block/Lot: 55.-6-15.48 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/31/2020 pursuant to which Building Permit No. 44676 dated 2/7/2020 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Meklenburg,Linda of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 44676 02-28-2020 PLUMBERS CERTIFICATION DATED uthorized Signature TOWN OF SOUTHOLD BUILDING DEPARTMENT s TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 44676 Date: 2/7/2020 Permission is hereby granted to: Meklenburg, Linda 1110 Tuthill Road Ext Southold, NY 11971 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 1110 Tuthill Rd Ext, Southold SCTM # 473889 Sec/Block/Lot# 55.-6-15.48 Pursuant to application dated 1/31/2020 and approved by the Building Inspector. To expire on 8/8/2021. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 i pector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (9-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00,Commercial $15.00 Date. ( 7 v Z New Construction: 110 Old or Pre-existing Building: (check one) Location of Property: J U 0 l Q l CX I �6 vA 6' 11571 House No. �c, Street Hamlet Owner or Owners of Property: 1 n _ �(/► Suffolk County Tax Map No 1000, Section �jBlock Lot I S. Ca Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ AppliLnl Signature of Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Ar Southold,NY 11971-0959 sean.deviin(aD-town.southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To Linda Meklenburg Address: 1110 Tuthill Rd city,Southold Sr NY zip: 11971 Building Permit#. 44676 section: 55 Block 6 Lot 15.48 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor, DBA: VIVint Solar License No. 52346-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceding Fixtures Bath Exhaust Fan Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO2 Detectors Sub Panel A/C Blower Range Recpt Ceding Fan Combo Smoke/CO Transformer UC Lights Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 4'LED Exit Fixtures Pump Other Equipment 9kW Roof Mounted Photo Voltaic Solar System w/ 30- Q Peak BLK G4 30OW Modules, Enphase IQ7-60-2-US Inverter, Photovoltaic Rapid Shutdown AC Disconnect Notes: Solar i Inspector Signature: Date: February 28, 2020 S Devlin-Cert Electrical Compliance Form As 1 - Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) I, b n fk— Rlex& 2ing at /a ! �`-1 k l ff (Print property owner's name) (Mailing Address) do hereby authorize���� � I�''�� ��✓ (Agent) to apply on my behalf to the Southold Building Department. 7— ;2-o Owner's ignatur (Date) G� ztk ler) o (Print Owner's Name) NICOLE GIORGETTI (Votary Public, State of New York No 01G16292933 Qualified in Suffolk County Commission Expires November 12,20 dam`I CONSENT.TO INSPECTION �,&16e—tn �VLqj,-,Ihe undersigned, do hereby state: g (es) Y Owner(s)Name(s) That the under igned (is) (are)the owner s) of t} premises in the Town of Southold, located at which is shown and designated on the Suffolk County Tax Map as District 1000, Section �5,. , Block to , Lot j S-o LIS That the undersigned(has) (have) filed, or cause to be filed, an application in the Southold Town Building Inspector's Office for the following: That the undersigned do(es)hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon,to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws, ordinances,rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections, do(es) so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances,rules or regulations of the Town of Southold. Dated: l 3\,o kJ ,(Signae 4. e fkj `1 ; 'S (Print Name) (Signature) (Print Name) �o�a0FsoUTyOlo [i 4 7& I I 'trr rL u"Zp-i5 # # TO N OF SOUTHOLD BUILDING DEPT. cou765-1802 INSPECTION [ ] FOUNDATION 1ST - [ ] ROUGH PLBG. [ ] FOUNDATION-2ND_ [ ] INSULATIOWCAULKING [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION FIRE-RESISTANT CONSTRUCTION [ -]`FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) So 4M2 [ ] CODE VIOLATION [ ] PRE C/O REMARKS:. DATE INSPECTOR FIELD INSPECTION REPORT -DATE COMMENTS FOUNDATION (1ST) ----------------------------------- FOUNDATION (2ND) - 1 � ROUGH FRAMING& PLUMBING y I� r INSULATION PER N.Y. y STATE ENERGY CODE FINAL ADDITIONAL COMMENTS C� 0 Z m X CD ' o z H x • d TOWN OF SOUTHOL-D BUILDING PERMIT APPLICATION CHECKLIST BUILD kNG DEPARTMENT Do,you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,WY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. Check Septic Form ry N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined 20Z Single&Separate Storm-Water Assessment Form � Contact: '1/;✓���- ,*Approved� Approved ,20 Mail to: 1 -7 Disapproved a/c W�5 ��.9.►Mr ill/ f 1 Sn o Phone: 51(p S qq $.70 +Expiration ,20 1/ Bui ding ctor APPLICATION FOR BUILDING PERMIT 2020 e-,-) Date—\J&V-1 , 20 PO INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or „ areas, and waterways. c. The work covered by this application may not be commenced before issuance of BuildingPermit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an ;;'addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and'other applicable Laws,Ordinances or ! Regulations,for the construction of buildings, additions,or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. ( ' of a p ican or name,if a corporation) A 0, v Lk _A" [x`111 S9 ailing address of applicant) "j State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder ,,';Name of owner of premises L l cn UCL kle' I, LI (As on the tax roll or latest d d) '?...If applicant is a corporation, signature of duly authorized officer ,1 (Name and title of corporate officer) Builders License No. Ia- 518 Plumbers License No. ,a Electricians License No. Other Trade's License No. 1. Location of land o whi h prop ed orl 11 be done: House Number Street Hamlet. County Tax Map No. 1000 Section -555 Block1 l0' Lot g l 1 Subdivision �J�J Q I 'Filed Map NoI.I Lot jj.(t I 2. State existing,use and occupancy of premises and inter edl use and occupancy of_proposed constriction: ' a. Existing use and,occupancy 1N--j I jI b. Intended use and occupancy Y, �,o 3. Nature of work(check which applicable):New Building Additic i i_ Alteration Repair Removal Demolition_I Ot4,er Wor ci�-i,.,p, © I (Description) 4. Estimated Cost 1`�o �� _ Fee To be paid on filing this application, 5. If dwelling,number of dwellings _ Numbei of dwellin units o'L each floor If garage, number of cars 6. If business, commercial or mixed o cupancy, specify naturae and;extent of each _pe of use. j 7. '.Dimensions of existing structures, i r any: Front i i Read Depth Height Nu-nber of Stories— j Dimensions of same structure w th alterations or a4ditions., Front Rear Depth Hight _ _ �r _ Number of 6tones 8. Dimensions of entire new construction: Front I rRear 1 : ,­-,,Devth Height Iyumber of Stories_ 9. Size of lot: Front Rear IJ DI 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premiE es are situated 12. Does proposed'construction violate any zoning law, ord�nahce or re la Tu dtion? i S — NO� i 1 � I � I 13. Will lot be re-graded? YES N Q Will excess flit-.J�6 Tem6ved f�6m pre ises: PERMIT# V'f b76 Address: Switches Outlets G FI's Surface Wo Sconces 6 H H's _ UC Lts k' at, � Fans Fridge HW Exhaust\ Oven Dryer al L(, Smokes DW Service Carbon Micro Generator Combo Cooktop Transfer AC AH Mini Special: Comments R zb00 , L 39.Ey, , q° \ 7 + �o 0 SP v y 1pm \ , 4 V I OCT2 61992 , i BLDG. TOWN OP SOUTNOLP SURVEY FOR KENNETH PEKLENNWO B LINDA M.MEKLENBURI a 1990 LOT NO.42, HIGHPOINT MEADOWS,SECTION THREE" CT gCPL2g1990 AT SOUTHOLD DATE AUG 15,1990 7OWN OF SOUTHOLD SCALE 1"-40' SUFFOLK COUNTY,NEW YORK NO 90-0519 NwurHaNu[e ALrwrlwoAAoomoN ro nils' GUARANTEED SURVEY R•VIOLATNN ON SECTION 1,1109 or rHt KENNETH F !M• N[w TONER STAT[$&CATION u• OVOP/n W THIS RRVtr NOT MEANING THE LAND LINDA M H �O s9AVEVWS MUD DEAL ON[NIMUD OR fINLI TICOR N Y NOT EE CONfNtDI TD DE A VALID Twut twT TIiL NwAHbr[as Nlo no NsnoH SHALL RW oNLT,'10 HEALTH DEPARTMENT--DATA FOR APPROIRL TO CONSTRUC T TK vote"NA MIND THt WIST Is MtPANEo ANO SN WAS DEHALI To THE nTLC coHPANT,$ovMN- N NSIAApT� W-NO t(�01 IDEfIA•1�1rT[ IC rEHTAL MtNCT AM L[NONS INSTITUTION LISTED Dow YY A-wwtT1�1-,DE.-rOOt 1 LOT.�,@� HDEEON.Et0 TO TAE AL/IMDES 0/THE L[NOINS SWAM ASE SO @nLLeNe TITIN 100 RET OF THIS PRO►NTV N1sT1TUTtr SUAAANTE[S ARE NOT i EEAOLE orRER TINY TADS[VERISM'R� TO AfEfl10HAL MfTITUTM"N sUEDEOUEMT I� •TOR 1,199 ek"LI NG UMn Own"MISS PDE THIS NDEIDESDE OeMERf •ILL ONWGfM 1,0 TIN STS11tlAs M TIS[N/1'<H COMITY OAA11T11EHT O culeTw f TRUC KRIS A /NON PgnTT LINES OT MALTS SERVICES ro ,& eTRYCNOT T ADE POR A fPSTASL low, Or AIPLKMT NR/0EE ARE MK 90T TO eL VEEO TO EfTAELIN ®NOPE9/T UAL9 001!UN THE[IKCTION OF ftNt[S A9fItEDE m YOUNG a► YOUNG AM ERH"W",I�EIr*AT"C NOTE. A n STAKE ■z MONUMENT ALOEN W YOUNG,PROFESSIONAL ENGINEER SUBDIVISION MAP FILED IN TM OFFICE OF THE CLERK OF SUFFOLK COUNTY ON MAR 19,1990 AS FILE NO.9912. AND LAND SURVEYOR N Y.S UCENSE NO 12645 HOWARD LAND a noLawlnSESLewlsor CT1Mw19CEtwaftsSlfNtrRNEtRtI ICENSEIqYousla�R31U11YETOR + AY DEER PIAN e9afiSIH AA ORMA OMAM�fRER OfMeNf E. MANDIS A SONS INC _ suffa C®unty i3ep4,Of La�P9censing Cos►sumea AaiQs ELECTRtCAL LICENSE ! ' .,. GASTER .. liame i MICHAEL T MORTENSEN yA' business Name CO VtVINTSOLAR DEVELOPER LLC aas f13a the fymfo? .� k M E-52346 file county License iqusnbe[: dz Issued: 09:2412013 FY � Commissioner sxpi fes: 0910112021 6 f y gastae-l't Fla e, 6r�� tere 8 rr 6 , 0 t v"® RK Workers' CERTIFICATE OF STATE Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE Board 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured •Vivint Solar Developer,LLC 801-377-9111 1800 W Ashton Blvd. Lehi,UT 84043 1c..NYS Unemployment Insurance Employer Registration Number of" • Insured Work Location of Insured(Only required if coverage rs specirically limited to 1d.Federal Employer Identification Number of Insured or Social Security certain locations in New York State,i e.,a Wrap-Up Policy) Number 80-0756438 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier' (Entity Being Listed as the Certificate Holder) American Zurich Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"1a" 53095 Route 25 Southold,NY 11971 W0150960130.9 3c.Policy effective period 11/01/2019 to 11/01/2020 3d.The Proprietor,Partners or Executive Officers are ❑X included.(Only check box if all partners/officers included) ❑ all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above'in box"3"insures the business referenced above in box"1 a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers'Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums.that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mad.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box"3c",whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed, nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note: Upon cancellation of the workers'compensation policy indicated on this form, if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Mark Elias (Print name of authorized representative or licensed agent of insurance carrier) Approved by: 10/31/2019 (Signature) (Date) Title:Sr.Vice President Telephone Number of authorized representative or licensed agent of insurance carrier: 212-553-5367 Please Note:Only insurance carriers and their licensed agents`are authorized to issue Form C-105.2.Insurance brokers are NOT authorized to issue it. C-105.2 (9-17)• www.wcb.ny.gov STATE Compensation YORK Workers' OF INSURANCE COVERAGE Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1 a.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured VIVINT SOLAR DEVELOPER, LLC 3 WESTCHESTER PLAZA 8017052900 ELMSFORD, NY 10523 Work Location of Insured(Only required if coverage is specilically limited to 1c Federal Employer Identification Number of Insured certain locations in New York State,i e.,Wrap-Up Policy) or Social Security Number 80-0756438 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) Town of Southold Standard Security Life Insurance Company of New York 53095 Route 25 3b.Policy Number of Entity Listed in Box"1a" Southold, NY 11971 D95557-002 3c.Policy effective period 6/10/2013 to 11/24/2020 4. Policy provides the following benefits: A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only. 5. Policy covers: Q A All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employer's employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as desc d above.' Date Signed 11/26/2019 By (Signature of insurance carrier's authoriz d representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number (212) 355-4141 Name and Title SUPERVISOR-DBL/POLICY SERVICES; IMPORTANT: If Boxes 4A and 5A are checked, and this form Is signed by the Insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE.Mail it directly to the certificate holder. If Box 4B,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if Box 4C or 5B of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note: Only insurance carriers licensed to write NYS disability and pard family leave benefits insurance policies and NYS licensed insurance agents of those insurance carvers are authorized to issue Form DB-120.1 Insurance brokers are NOT authorized to issue this form. DB-1120.1 (10-17) 1111111 1I11111111111 ill1111111111111111111111111111 DB 120.1 (10-17) r ACORO® CERTIFICATE OF LIABILITY INSURANCE °91122/20 9°""YY' THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE"COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH USA INC NAME: 122517TH STREET,SUITE 1300 PHCNN E • FAXNo DENVER,CO 80202-5534 ADDRESS Attn:Denver CedRequest@marsh com I Fax.212-9484381 INSURERS AFFORDING COVERAGE NMC# INSURER A:AXIS Specialty,Europe SE INSURED Vvint Solar Developer,LLC INSURER B Zurich American Insurance Company 16535 1800 W.Ashton Blvd. INSURER c American Zurich Insurance Company 40142 Lehi,UT 84043 INSURER 0. INSURER E: INSURER F; COVERAGES CERTIFICATE NUMBER: SEA-003638189-01 REVISION NUMBER: 2 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD- INDICATED NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT-TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LTR POLICY NUMBER MM/DD/YYYY MNUDDIYYYY LIMITS A X COMMERCIAL GENERAL LIABILITY 3776500119ES 12/01/2019 11/0112020 EACH OCCURRENCE $ 1,000,000 DAMAGE TO RENTED CLAIMS-MADE FxIOCCUR - PREMISES Ea occurrence $ 1,000,000 MED EXP(Any one person) $ 10,000 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 2,000,000 X POLICY PRO ❑LOC JECT PRODUCTS-COMP/OP AGG $ 1,000,000 OTHER 1 1 $- B AUTOMOBILE LIABILITY BAP509601505 11/0112019 11/01/2020 COMBINED SINGLE LIMIT $ 1,000,000 Ea accident X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED BODILY INJURY Per accident $ AUTOS ONLY AUTOS ( ) X HIRED X NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident $ X UMBRELLA LIAB X I OCCUR"- 3776500219ES 12101/2019 11/01/2020 EACH OCCURRENCE $ 5,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $ '5,000,000 DED RETENTION $ C WORKERS COMPENSATION WC509601305(AOS) 11/01/2019 11101/2020 X I_PE R OTH- B AND EMPLOYERS'LIABILI Y Y/N STATUTE ER ANYPROPRIETOR/PARTNER/EXECUTIVE WC509601405(MA) 11/01/2019 11/01/2020 E L.EACH ACCIDENT $ 1,000,000 OFFICER/MEMBEREXCLUDED? NI NIA EL DISEASE-EA $ (Mandatory in NH) 1,000,000 If yes,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,maybe attached if more space Is required) CERTIFICATE HOLDER CANCELLATION Town of Southold SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 53095 Route 25 THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN PO Box 1179 ACCORDANCE WITH THE POLICY PROVISIONS. Southold,NY 11971 AUTHORIZED REPRESENTATIVE of Marsh USA Inc, Jon Lindstrom ' @ 1988-2016 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD 1V V APPROVED AS NOT D DATE: �yi& B.P:# Aa FEE: eBY: NOTIFY BUILDING DEPARTMENT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION'- TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW ELECTRICAL YORK STATE. NOT 'RESPONSIBLE FOR INSPECTION REQUIRED DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF SGUTH90 NTNG BOARD --60%fHe-B i WTEES r® NI DFG OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY ton Blvd. '�.I � it�€ sol a �� 180®! /ehi, UT 84043 W Structural Group J.Matthew Walsh, PE Kirk M.Nelson, SE Samuel Brown,PE- Civil Director of Engineering Structural Engineering Structural Engineenng james.walsh@vivintsolar.com kirk.nelson@vivintsolar.com sam.brown@vivintsolar.com January 16, 2020 Re: Structural Engineering Services Meklenburg Residence 1110 Tuthill Road Ext, Southold, NY S-6287937; NY-01 To Whom It May Concern: We have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit by a representative from our office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches,and verification forms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. Based on the above information, we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: A. Description of Residence: The existing residence has typical wood framing construction with a maximum of two layers of composite shingle roofing. All wood material utilized for the roof system is assumed to be Douglas Fir-Larch#2 or better with standard construction components. The designed areas of the home consist of the following framing methods: • Roof Section: Dimensional lumber- 2x8 at 16" on center and 2x4 collar ties at 48" on center. Survey photos indicate that there was free access to verify the framing size and spacing. B. Loading Criteria 9.75 PSF= Dead Load (roofing/framing) 3.00 PSF= Dead Load (solar panels/mounting hardware) 12.75 PSF=Total Dead Load 20 PSF= Roof Live Load 30 PSF= Ground Snow Load (based on local requirements) Wind speed of 130 mph (based on Exposure Category B-the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) C. Solar Panel Anchorage 1. Installation shall proceed in accordance with the applicable guidelines and recommendations indicated below. If, during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. Unirac, Inc. Installation Manual,which can be found on the Unirac, Inc.website(www.unirac.com). 2. The solar panels are 1'/" thick. At no time will the panels be mounted higher than 10" above the existing surface of the roof. Page 1 of 2 w0 1 nl s r j Page 2 of 2 3. The following mounting types shall be used. Please refer to the mounting details for the associated required penetration depth. Based on our evaluation, the pullout demand is less than the maximum allowable per connection and therefore is adequate. • Unirac with SFM: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS) of timber construction specifications for Douglas Fir-Larch is 235 lbs/inch penetration. 4. Fasteners are installed to meet industry standards and this document satisfies requirements in 2015 IRC R802.10.4 verifying that the fasteners will not adversely affect the roof framing. 5. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind load uplift procedures of ASCE 7-10 and is specified below. These spacing requirements apply to all mount types indicated above. The following values have been verified by in-house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections should be staggered, where possible,to distribute load to adjacent members. Modules in Landscape Modules in Portrait Roof Zone Interior Ede Corner Interior Ede Corner Max Vertical Spacing in 40 40 40 66 66 66 Max Horizontal Spacing in 48 48 48 48 48 48 Max Uplift Load Ibs 288 188 106 170 111 63 D.Summary Based on the above evaluation, with appropriate panel anchors being utilized the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly. This evaluation has been performed for the structural elements only and verifies that they are in conformance with the 2017 New York State Uniform Code Supplement, the 2015 IRC, current industry standards and practice, and the information supplied to us at the time of this report. If there are any questions regarding the above, or if more information is required, please contact me. Regards, ��OF NEIN Y J. Matthew Walsh, PE �P ,PS W1444 NY License No. 099739 m z ZN�OA 099739 ROPZESS►oNP� 01/16/2020 wows �. l r JURISDICTIONAL NOTES GOVERNING�OOIES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES a 2015 INTERNATIONAL RESIDENTIAL CODE b 2017 NEW YORK STATE UNIFORM CODE SUPPLEMENT c 2015 INTERNATIONAL FIRE CODE d 2014 NATIONAL ELECTRICAL CODE e. ANY OTHER LOCAL AMENDMENTS SHEET INDEX: PV 0.0-COVER SHEET PV 1,0-SITE PLAN S 1.0-MOUNT DETAILS E 1,0-ELECTRICAL DIAGRAM E 2.0-ELECTRICAL NOTES E 3.0-WARNING LABELS E 4.0-WARNING LABEL LOCATIONS GENERAL ELECTRICAL NOTES' GENERAL STRUCTURAL NOTES a ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL a THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING MEANS DESIGNED AND LISTED FOR SUCH USE FOR ROOF-MOUNTED THE SFM SYSTEM BY UNIRAC THE MOUNTING FEET ARE TO BE SPACED AS SYSTEMS,WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF SHOWN IN THE DETAILS,AND MUST BE STAGGERED TO ADJACENT FRAMING THE ROOF SURFACE MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD ' b ANY CODE VIOLATIONS EVIDENT IN THE INTERCONNECTION PANEL WILL BE b UNLESS NOTED OTHERWISE,MOUNTING ANCHORS SHALL BE%s°LAG N"-": CORRECTED ON INSTALLATION SCREWS WITH A MINIMUM OF 2Y2'PENETRATION INTO ROOF FRAMING a' c SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ALL RELEVANT CODE c THE PROPOSED PV SYSTEM ADDS 3 0 psf TO THE ROOF FRAMING SYSTEM d RAPID SHUTDOWN INITIATION TAKES PLACE AT THE AC DISCONNECT RAPID d ROOF LIVE LOAD=20 psf TYPICAL,0 psf UNDER NEW PV SYSTEM SHUTDOWN COMMENCES UPON LOSS OF UTILITY SOURCE VOLTAGE e GROUND SNOW LOAD=30 psf .e SEE`E 10 AND*E 2 0 FOR DIAGRAMS,CALCULATIONS,SCHEDULE AND f WIND SPEED=130 mph SPECIFICATIONS 9 EXPOSURE CATEGORY f= vlvkA.Solar r� M1 1800 ASHTON61-0 HI,0T,84043 1 877 404 4129 9Ro� =lan PHOTOVOLTAIC SYSTEM SPECIFICATIONS: NY LICENSE 12000324713 SYSTEM SIZE-9.000kW DC I 7.500kW AC MEKLENBURG RESIDENCE MODULE TYPE&AMOUNT-(30)Hanwha Solar Q.PEAK-BLK-G4.1 300w 1 110 SOT ROAD EXT SOUTHOLD.OLD,NY,11971 MODULE DIMENSIONS-(UW/H)66.75139.37'/1.26" UTILITY ACCOUNT#9634609722 INVERTER-(30)Enphase Energy IQ7-60-2-US { INTERCONNECTION METHOD(GRID-TIED)-LOAD BREAKER SERVICE#S-6267937 REGOPERATING CENTER NY-01 C OVER DATE IAV2020 DRAWN BY DIN SHEET PV CIRCUIT(S). SLOPE 28 SYSTEM LEGEND 1 ® #1)15 MODULES ZIMUTH- -224 PV SYSTEM SIZE. MATERIAL- 1110 TUTHILL ROAD EXT ® #2)15MODULES COMPOSITION SHINGLE NEW9.000kWDC I 7500kWAC EXISTING INIEF40R MAIN SERVICE PANEL 8 FRONT OF HOUSE ®POINT OF INTERCONNECTION TIED TO DETACHE UTILITY METER 1,98373259 NEW PV SYSTEM AC DISCONNECT(RSD) LOCATED WITHIN 10'OF MSP, C NEW DEDICATED PV SYSTEM COMBINER PANEL 30 NEW HANWHA SOLAR Q,PEAK-BLK-G4 1300W MODULES :... • NEW ENPHASE ENERGY IQ7-60-2-US INVERTERS, - M UNTE ON HE BACK OF EACH MODULE, • .••.::.:::.;...... NEW PV CONDUIT RUN'SEE EEI 0 CONDUITSCHEDULE EXTERIOR RUN ATTIC RUN .�:.�:•::..:.............:: •::.•r•:::....::::.:�::::.�:..:..... ..... ... ...,.....,..... ..... C ..........:.......... .. .:•:..::.:•:•:•:::':::. •.••...........,........,......,..•.. .......:••...�.'.• •...:.:.��::"•::•::'t::::...:�.::: �NEWJUNCTION BOX(MOUNTED WITHSOLADECK) qe :.t. M ..; . :... .. :•. FIRE CODE " . ... •.:.:."" .. .. _= RIDGE 18"1 PATHWAY 36 .. . . .:.. :. . - � 8 PA OFFSET _ ...::{ ::':'. ... ...................... ........... .... .. ... .................,.,..,. ......,,...................... .. TIFY THAT THIS DOCUMENT ...•.�.......::.:..•::....:. ........ .......... .......... VARNING I HEREBY CER ..................... ::••::•?:" ..:,'•:'�'•.:.:"•i•:; WAS PREPARED OR APPROVED BY THE ENGINEER OF .:.:•::... :::•.:. ..•.. ............................. :.:. ...:•.: .. ... ...................... ........ ....:. ............... ......................... ;, .. ...............:'::::.... . ... .. ....................................... .............. ............,, ......,.• .L .®. ....•:.••.:�.:�.:�:.:�•::.:::.:::•:,�t;'•:.::::•::•:t:.:::.�:.�:.�:.:�:.� ::.••: ........... ' •.:•i••tt::••' RECORD ANY ALTERATION TO THIS DOCUMENT IS IN VIOLATION OF ARTICLE 1457209(2}UNLESS ACTING UNDER THE ENGINEER OF RECORD'S DIRECTION, Nt ��pF NE6yY i.P ES wq< p'Q O ZN� 099739 ��C2 ARo�ssloNP� vivint. olar 1 877 404 4129 O MEKLENBURG RESIDENCE 1110 TUTHILL ROAD EXT SOUTHOLD,NY,11971 UTILITY ACCOUNT#9634609722 ACCESS PATHWAY, SERVICE m s eza7937 SITE PLAN = OR ACCESS ROOFREGIONAL OPERA NG CENTER NY-01 PV 1.0 ROOF ACCESS POINT DATE 111112020 NO OPENINGS LOCATED SCALE 3/16"= I-0" BELOW ACCESS POINTS DRAWN BY DIN MOUNTING LEGEND 5/16'0 SS LAG SCR PER MFR 16'0 LAG SCREW PER MFR MODULE LASHING SFM-9"ATTACHED SPLICE $10 NOT TO SCALE 2112'MIN 5/16.0 SS LAG SCREW PER MFR LAG SCREWS 5/16"DIA STAINLESS STEEL WIMIN 2 5'EMBED INTO FRAMING MEMBERS TOROUE-13 t(-2 FT-LBS - SFM-TRIMRAIL WITH Ilk 1 SFM-ROOF ATTACHMENT 2 SECTION VIEW s ROOF ATTACHMENT 5 SFM-3"RAIL 5 1 0 NOT TO STALE SLD NDT TO STALE S 1 O NOT TO SCALE S 1 D NOTTO SCALE SFM 9'ATTACHED SPLIC ICLAMP-ATTACHMENT CLAMP+ATTACHMENT COUPLING COUPLING SFM 9'SPLICE 'WARNING I HEREBY CERTIFY THAT THIS DOCUMENT WAS PREPARED OR APPROVED BY THE ENGINEER OF MODULE _ RECORD ANY ALTERATION TO THIS DOCUMENT IS IN SFM 3' VIOLATION OF ARTICLE 145 7209(2,UNLESS ACTING ILSCO SGB-4 GROUNDING LUGS RAFTER UNDER THE ENGINEER OF RECORD'S DIRECTION s16 �mTo E of NEIV MODULE ,LQ' S Wq< 0 RAFTER Gj ) v * f 9 MODULES IN PORTRAIT LANDSPACE TRIMRAIL SPLICE 51.0 NOTTOSCALE �N _ 2 TRIMRAIL ROOF ATTACHMENT, SEE TABLE 099739 6 SFM LAYOUT TRIMRAIL eK - 9"SPLICE ONE HOLE STEEL STRAP CONDUIT ARpfESsIpNP� S 1 0 MOTTO SCALE 5 1 0 NDT TO SCALE CANTILEVER U3 OR LESS CONDUIT MOUNT BRACKET �`y jJ�IJO(ft•S®Iar DSCAPE=MAX 48"(4'-0') 1 877 404 4129 PORTRAIT=MAX 48°(4'-07 COUPLING CLAMP FLASHING OR TILE STRAP1 12' MODULE 35mm PROFILE ' MEKLENBURG RESIDENCE RAPT ER — — — 1110 TUTHILL ROAD EXT SOUTHOLD,NY,11971 to PV SYSTEM MOUNTING DETAIL RAFTER Ll SFM-TRIMRAIL 12 CONDUIT MOUNTING DETAIL UTILITY ACCOUNT#9634609722 Ya6"AT16'OCS10 NOTTOS 510 NOT TO SCALE S10 NOT TO SCALE 11 40mm PROFILE SERVICE#513287937 MOUNT DETAILS OPERAREGIOTING CENTER NY-01 S •O DATE 1111M1020 SCALE NOT TO SCALE DRAWN BY DIN Photovoltaic System Conduit Conductor Schedule(Unless Otherwise Specified Conductors Shall be Copper) DC System Size(Watts) 9000 Tag Description Wire Gauge 9 of Conductors/Color Conduit Type Conduit Size ry AC System Size(Watts) 7500 1 Inverter Output(Enphase CiCable) 12 AWG 2(L1,1.2) Free Air N/A a Total Module Count 30 1 EGC(Bare) 6AWG 1BARE Free Air NIA y 2 Inverter Output(THWN-2) 12 AWG 4(213,212) FMC 1/2" w O } 2 EGC(THWN-21 12 AWG 1(GRN) FMC 1/2" Z m 3 Inverter Output(THWN-2) 12 AWG 4(21.1,212) EMT 1/2" a r O o 3 EGC(THWN-2) 12 AWG 1(GRN) EMT 1/2" 4 Invetter Output(THWN-2) 8AWG3(L1,.2,N)B/R/W JEMT 3/4" v O 4 EGC(THWN-2) 30 AWG '(GRN) JEMT 3/4" , y:,9 -o a m a u` N a 0 v n 3 O F- w _z m m Point of Interconnection,Load N Rapid Shutdown Side 70512(D)(2)(3)(b) N Disconnect,Square D Inverter EnphaselQ7-60-2-US 20A DU222RB,24OV/60A, J IOA Unfused,NEMA3 LIUN h N = w 20A Z z Z N° M SHEET NAME. M' Olin 2 30A Existing SquareD PV Circa 15 L 2 Zo Modules/ 1 Alm 240V/2BOA Service Panel, C Op Single Phase,with 200A rp Parallel __ Olm ylo Main Disconnect 0 9� t i 4 4 Minimum GECsize4 A` SHEET PV Cimmt115 f 2 lm om mer ane np ase Combi ner K-I Q- AWGtopper NUMBER. Modules/ 1 Ah11-240-3 64 240V Con.nuous,protection Parallel — max 60A breaker on solar ouput,wnh 30 KAIC circurt breakers NEMA4 Junction Box I Vrsi a c a a nife'AC y-4 Disconnect W PV Module Rating @ STC Conductor Calculations N Module Make Model Hanwha 4 PEAK BLK-G4.1300 SOLAR MODULE Max Power-Paint Current(Imp) 926 Amps Wire gauge calculated from 31D 15(8)(16)&(17)with ambient temperature calculations from � ^ m a, o Max Power-Point Voltage(Vmp) 3241 Volts 310 15(B)(2)(a)&310 15(13)(3)(c)and raceway fill adjustments from 310 15(B)(3)(a).Conduit on a ti c the roof shall be installed no less than 1"above the roof deck w y Open-Circuit Voltage(Voc) 39 76 Volts z a' Enphase Ira-60-2-us "Under Array"conductors use the 90°C ampacity in 310.15(8)(17)with relevant ambient 29 d MICR04NVERTERAT Short-Circuit Current(Isc) 977 Amps temperature adjustments = _ n H O o EACH MODULE ATTACHED Max Series Fuse(OCPD) 20 Amps PV Circuit conductors use the larger ampacity in 310 15(B)(16)or(17)using the 75"C column with _ = WITH ECOEBRIUM SOLAR Nam Max Power at STC(Pmax) 300 Watts the continuous duty uprating or the 90°C column with the relevant ambient temperature and v > o HARDWARE O us BARE CU GROUND Max System Voltage — 1000 V(IEC)(UL) raceway fill adjustments and without the continuous duty uprating per 690 8(B) — Voc Temperature Coefficient -0 28 %C Non-PV Circuit conductors use the ampacity in 310 15(B)(16)in the 75"C column or the 90°C (ATTACHED TO FIRST MODULE IN P / ARRAY)BALANCE OF ARRAY column with the relevant ambient temperature and raceway fill adjustments,whichever is less GROUNDING CONNECTIONS `� AC Output Current According to art 690 8 B 1 30 Ams (110 14(C)&310 15(A)(2)) The rating of the conductor after adjustments shall be greater than, MADE THROUGH ARRAY P g ( )( ) P i or equal to,the continuous duty uprated current HARDWARE Nominal AC Voltage 240 Volts THIS PANEL IS FED BY MULTIPLE SOURCES(UTILITY AND SOLAR) More information about conductor calculations can be provided upon request MICROINVERTER CONNECTION Calc.Ex Wire Ampacity xAmblent Temp Corr Factorx Conduit Fill Adj Factor>=Output Current TO ENGAGE TRUNK CABLE 1 (Tag 1 Under Array) ra_ Rooftop conductor ampacities designed in compliance with art Inverter Output 12 AWG rated 30 A, 30 A x 0 96 x 1=28 8 A>=15 A 690 8,Tables 310 15(131)(2)(a),310 15(B)(3)(a),310 15(B)(3)(c), (Tag 2 Attic) 310 15(B)(16),Chapter 9 Table 4,5,&9 Location specific Inverter Output:12 AWG rated 30A, 30 A x 0 71 x 0 8=17.04 A>=-15 A o temperature obtained from ASHRAE 2017 data tables. (Tag 3 On Roof) Inverter Make/Model Enphase 147-60-2-US ASHRAE 2017-FRANCIS S GABRESKI AP Inverter Output 12 AWG rated 30 A, 30 A x 0.71 x 0 8=17 04 A>=15 A � Max.Dc Volt Rating 48 Volts Highest Monthly 2%D B Design Temp 34'C (Tag 4 Exterior) o Max Power at 40C 240 Watts Lowest Min Mean Extreme D B -22 4'C Inverter Output 8 AWG rated 50 A, 50 A>=37 5 A ti Nominal AC Voltage 240 Volts � v Max AC Current 1 Amps � Max OCPD Rating 20 Amps Max Panels/Circuit 16 Short Circuit Current 15 Amps m N CCPD Calculations a Breakers sized according to continuous duty output current PV circuit nominal current based off of modules per Circuit X(1 25(art 690 8(A)])X(1 Max AC current per micro-inverter) S Circuit k1=15 modules,Output Current w/continuous duty=18 75<=20A Breaker w Circuit#2=15 modules,Output Current w/continuous duty=18 75<=20A Breaker z m system output current w/continuous duty=37 5<=40A(System OCPD) > Z w ^ a Jm ^ Other Notes z z z •Designed according to and all code citations are relevant to the 2014 National Electrical Code _ SHEET •All specified equipment grounding devices/components must be listed for use NAME •Inverters are equipped with rapid shut down •690 11 DC Arcfault circuit protection Enphase micro inverters are exempt because there are no DC stnngs N Y an 0 Z a SHEET NUMBER N W N ` N � W ~ n � N Main Service Panel Signage °¢ v (Installed on the Face of the Service Meter) z i per 690.54,690 56(B),&705 10 m= o X, 1z O o v o > Combiner Boxes,J-Boxes,Disconnects,Devices,& Inverters In Un-Grounded Systems per 690 35(F)(String •o o • z o • • w; systems) e o • •• o op • -v "i Conduit,Raceways,and 1-Boxes Labeled Eve 10' AC Disconnect and Any Load Centers(Combiner Panel) per 690 17(E)&705 12 ® ®• ® ® ,•® ® ® ® • ® 4 na a e v '� c' o o• ov. DC Disconnect per 690 13(g)690 17(E) v U r, o e • • • o 0• 0 0 it® N a Inverter Output Connection(Solar Breaker)at O Main Service Panel] er 705 12 D)2)(b w '' � ...0 •I� •• • Z D• •fl• • _ W W N apt 0 Ol •• W � w n • Q Q Rapid Shutdown per 690 56(C) Rapid Shutdown Disconnect per 690 12(5)Installed On AC Disconnect z z z • e • • • • _ ® ®o •- o SHEET .ice • •o NAME: Fs m e_ W a `m ua o0 � � a SHEET NUMBER* ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY SHALL BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8"WHITE ARIAL FONT TEXT,AND HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED M ALL PLACARDS SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS HANDWRITTEN SIGNS WILL NOT BE ACCEPTABLE yj CAUTION SOLARELECTRICSYSTEMCONNECTED /1 WARNING DUALPOWERSOURCE (] WARNING WARNING N 1 Property of Vivant Solar 4 SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM 9 ELECTRICAL SHOCK HAZARD 12 ELECTRICAL SHOCK HAZARD R w n MAIN BREAKER DE-RATED TO***DUE TO SOLAR RATED AC OUTPUT CURRENT ***A IF A GROUND FAULT IS INDICATED, THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE o CIRCUITS NOM OPERATING AC VOLTAGE•***V NORMALLY GROUNDED CONDUCTORS UNGROUNDED AND MAY BE ENERGIZED O MAX OF***AMPS PV SOURCE ALLOWED Property of Vwint Solar MAY BE UNGROUNDED AND ENERGIZED Property of Vrvint Solar z m DO NOT INCREASE MAIN BREAKER RATING WARNING PHOTOVOLTAIC POWER SOURCE Property of Vrvint Solar SITE PLAN PLACARD SHOWING ADDITIONAL POWER m_ o Property ofVrvmtSolar 5 Property ofViwntSolar WARNING 13 SOURCE AND DISCONNECT LOCATIONS PLACARD v r WARNING PHOTOVOLTAIC AC DISCONNECT10 INVERTER OUTPUT CONNECTION SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL w o o a 3 ELECTRICAL SHOCK HAZARD RATED AC OUTPUT CURRENT ***A DO NOT RELOCATE THIS OVERCURRENT DEVICE PANEL(only when necessary) DO NOTTOUCH TERMINALS TERMINALS ON BOTH 6 NOM OPERATING AC VOLTAGE ***V Property ofViv{ntSolar Property ofVrvintSolar THE LINE AND LOAD SIDES MAY BE ENERGIZED IN Property of Vivint Solar PHOTOVOLTAIC POWER SOURCE DC DISCONNECT THE OPEN POSITION PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID 11 RATED MAXIMUM POWER POINT CURRENT(IMP) ***A 14 PV rapid shutdown disconnect Property of Vwint Solar 7 SHUTDOWN RATED MAXIMUM POWER POINT VOLTAGE(VMP) ***V placard indicated on E 3 Property of Vivint Solar MAXIMUM SYSTEM VOLTAGE(VOC) ***V , PHOTOVOLTAIC DC DISCONNECT SHORT CIRCUIT CURRENT(ISC) ***A 8 Property of Viwnt Solar Property of Viwnt Solar ***-value calculated for each account,for specific value see the previous warning label page tw.a G O N 11 14 4 7 ROOFTOP ARRAY 8 #2) 6 6 2 4 13 IF APPLICABLE EVERY 10'AND a WITHIN 1'OF o ELBOWS •;YOc90 3 9 3 3 1 1 2 5 o`s�`2a TJ�T� 5 5 5 5 p O FG F w �O,e``,'P� , Z w MICRO-INVERTER '� `^ SYSTEMS P DC O O Z w w w N J Z n 9 DISCONNECT a a m INSIDE [OR] ____, _ _ _ _ SHEET SOLAR INVERTERS COMBINER PANEL VISIBLE/LOCKABLE VIVINT SOLAR METER VISIBLE/LOCKABLE SUB PANEL MAIN SERVICE NAME 12 JUNCTION (MAY BE ON ROOFTOP (WHEN USED) A/C DISCONNECT (WHERE REQUIRED) A/C DISCONNECT WHEN REQUIRED) 4DISCONNECT PANEL c STRING-INVERTER BO% 5 INTEGRATED WITH (WHERE REQUIRED) 10 c sysrEMs ARRAY) TYPICAL SOLAR GENERATION INSTALLATION INSIDE PANEL „ m (NOTALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) as SHEET ALL STICKERS DESCRIBED HEREIN SHALL BE MADE OF WEATHERPROOF ADHESIVE,THEY THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT(DC)CONDUIT,ENCLOSURES, NUMBER, SHALL BE REFLECTIVE,THEY SHALL CONTAIN NO SMALLER THAN 3/8"WHITE ARIAL FONT RACE-WAYS,CABLE ASSEMBLIES,JUNCTION BOXES COMBINER BOXES,AND DISCONNECTS TO ALERT THE FIRE SERVICE TO TEXT,AND HAVE A RED BACKGROUND,UNLESS OTHERWISE DEPICTED OR DESCRIBED ALL AVOID CUTTING THEM MARKINGS SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT(3048 MM),WITHIN 1 FT(305MM)OF PLACARDS SHALL BE WEATHER-RESISTANT,PERMANENTLY ETCHED PLACARDS TURNS OR BENDS AND WITHIN 1 FT(305 MM),ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES,WALLS OR HANDWRITTEN SIGNS WILL NOT BE ACCEPTABLE BARRIERS tai :..—r powered by DEA KDUO 11 i UNTUM, SOUR MODULE, i:.'r.,.'' ous.: n3xig V"`sSs'a; aF]'p x.nao¢ya Ck"ne 31R3 '3.e u!rw'i'.r,y .,_ignl p...n.-,3nrnsarx ae Cir S #« �° j a �a s � a5t ^Hve, aiyv T '��? " `�^ �Jvra�J_'4 - i .T" �^eymE .w F L" yy��'"°i Wx`**s.n, ,��':����.n, u, d ,._ x �$ s Ltli ;a F, m�e iso-Ifi .g Cel b 3"v-..s"nC. bas i.<;..�k'9' d7� i-_�,:,7s_�°•� G ANTUM TECHNOLOGY-LOW L EVELIZEiD COST OF ELEvTMCITY Higher yield per surface area. lover€SETS costs, higher power clams,arta!are ef�cfertey rate of�p go��S%. INNOVATWE ALL-WEATHER TECHNOLOGY Optimal yields.,whatever the weather with excellent.low-liglrt and temperature behavior. ENDURING HUGH PERFORMANCE Long-term yield security with Ant: LID Technology. _ QCLZUS Antf PID Technology=, blot-Sport Protect and Traceable Quality Tra-Q!". !7 TOP M woav EXTREME WEATHER RATING High-tech aluminum alloy frame. certified for high snow F5400PaJ and wind loads(4000 Pa)regarding IEC A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year ussri ria k, linear performance guarantee'. nj STATE OF THE.ART tlflOGULE TECHNOLOGY lc 40032587 Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. APT test conditions according to IEUTS 62804-12015, method B(-1500V, 168h) = See data sheet on rear for further THE IDEAL SOLUTION FOR: information Rooftop arrays on residential buildings - CELLSEngineered in Germany Format 66 3 in x 39 4m x 126 in(including frame) (1685mm x 1000mm x 32mm) Weight 412 Itis(18 7 kg) Front Cover 0 13 in(3 2 mm)thermally pre-stressed glass with anti-reflection technology F_- Back Cover Composite film Frame Black anodized aluminum Cell 6 x 20 monocrystalline Q.ANTUM solar half-cells Junction boy, 2 76-3 35 in x 1.97-2 76 in x 0 51-0 83 in (70-85 mm x 50-70 mm x 13-21 mm),decentralized,IP67 LI Cable 4 MM2 Solar caole,(+)a43.3 in(1100 mm), >:43.3 in R 100 mm) Connector Multi-Contact MC4,IP68 -T POWER"LASS 300 305 3.D 315 32C M 11,41 M n1l PC-Rcall Ivi A NO 2 A S71 N DARD 7 ES- ON 13 IT!ON S S-C 'Oil WER 3L---R AN CZ-='B' -;'W Power at MPP PRPP IW3 300 305 310 315 320 Short Circuit Current' ISC [A] 9.72 978 9.83 989 994 C_ Open Circuit Voltage, VOU (VI 3948 3975 4002 40.29 40.56 Current dt MPP 1.11 [A] 925 931 936 941 947 Voltage at MPF VIA" 3243 32.78 33.12 3346 3380 Efficiency' rl 17.8 18.1 2!18.4 a 18.7 >19.0 ,Ml'tl%9UMPERFORrvl4MCE.,AT.'IO,IMAL3PErZA-.INGCGNBI--i'Gi4S HMOT2 Power at MPP P.P1 (W] 224.1 2278 2316 2353 239 1 Short Circuit Current ISC [A] 783 7.88 792 7.97 8.01 Open Circuit Voltage Vac IV] 37 15 3740 3766 3791 3817 Current at MPP IMPP [A] 728 732 737 741 745 Voltage at MPP VMIP M 30.78 31.11 3144 31 76 32.08 Measurement tolerances Pwp_3%,1u V.x5%at STC I 000WIM2,25 x2 AM 1 513 according to IEC 60904-3 -800 WIM2,NMOT,spectrum AM 15 G Q CELLS PERFORMANCE!rYARRAfj7 PERF91MANCE AT LOW iRRADIANCE r- At least 98%of nominal power during first year ------------------ --------------- Thereafter max 0 54%degradation per year. ------------------------------- At least 93 1%of nominal power up to 10 years. At least 85%of nominal power up to 25 years 3� ss --------------- All data within measurement tolerances -- ----------- G ss Full warranties in accordance with the warranty terms of the Q CELLS sales organization of your respective country 20 .;0 1... IRRADIANCE WWI Typical module performance under low irradiance conditions in 'EARS comparison to STC conditions(25'C,1000W/ml) TEMPERATURE COEFFICIENTS Temperature Coefficient of 1,c a [%/1(] +0.04 Temperature Coefficient of Vac R (%/Kl -0.28 Temperature Coefficient of F , V (%/IQ -0.37 Normal Operating Module Temperature NmOT 1*1`1 109±5 4(43:tJ'C) Nif Maximum System Voltage Vin M 1000(IEC) 1000(UL) Safety Class 11 Maximum Series Fuse Rating -EA OCI 20 Fire Rating C(IEC)/TYPE I(UL) Max.Design Load,Push I Pull(UL)z [lbs/ft2l 75(3600 Pa)155(2667 Pa) Permitted module temperature -40'F up to+1857 an continuous duty (-40*C up to+85*C) Max.Test Load,Push I Pull MY [lbs/ttl 113(5400 Pa) 84(4000 Pal z see installation manual 00MRMSR UL 1703,VOE Quality Tested,CE-compliant, Number of Modules per Pallet 32 IEC 61215.2016,IEC 61730.2016,Application class A Number of Pallets per 53'Trailer 30 U Number of Pallets per 40'High Cuba Container 26 t; Pallet Dimensions(L x W x H) 69 3 in x 45.3 in x 46.9 in 2L C E C 0-.1. 1. 4`170° 1 1 703 (1760mm x 1150mm x 1190mm) 12� 111. Pallet Weight 14 15 1 bs(642 kg) NOTE installation instructions must oe followed See the installation and operating manual or contact our technical service department for further information on approved installation and use Z of this product Hanwha a CELLS America Inc. 300 Spectrum Center Drive,Suite 1250,Irvine.CA 92618,USA I TEL+1 949 748 59 96 1 EMAIL inquiry@us.q-cells cam I WEB www q-cells us Enphase Designed for higher powered modules, the smart grid- ready Enphase !Q 5 r >" T" and `Enphas jQ 6+Nlicror" are built on the sixth-generation platform and achieve the highest efficiency for module-level power electronics Microinverters and reduced cost per watt_ Part of the Enphase IQ System,the IQ 6 and IQ 6+ Micro integrate seamlessly with the Enphase 10 Envoy'. Enphase IQ Battery'"",and the Enphase Enlighten' monitoring and analysis software. The IQ 6 and IQ 6+ Micro are very reliable as they have fewer parts and undergo over 1 million hours of testing. Enphase provides an industry-leading warranty of up to 25 years Easy m Ms,ai� P M ' !ightweignt f' R Simple cable management Ruin-in rapid shutdown INE0 2014 1�7Od uC'`-,/e Cp1;mized for high powered modules SupporTs 60 and'2-cell moduies Maximizes energy oroducticn Sm a r-i y_,a :Ready Complies :vim fixed power factor,voitage ano frequency r;de-through requirements Remo- - e;y updates tc:espond to changing grid requirements Configurable"or varying grid pro-Files {a iear "'acre=tcoc=?gra _ � S)E �J" I ]vt-k (^yr 11Q6-56-_i'S=,?i _ 5e-u- DQ6PLir''S-72-2-,3^A;ND waPL S-_ Commonly used module pairings 19S VV-330 V%/+ 235'•!1-400 W Module compa'ibilrrp 60-cell PV modules only 50-cell and 72-cell':"V;nocuies Maximum'npuT:�C /oltage "8 V 62V Peak power trackmc voi,age 27 v-37 V 27'V-45 V Operating range 15';-"8 V 16 V-52 V Nlin/Max start voltage 22,/, 18', 22 V/62 V Max DC short circuit-current(moeule isc) ISA 15A Dvervoitage class DC Dort 'if it DC port backfeed under single fault 0 A u A Pv array configuration 1 x 1 ungrounded array,No additional DC side protection required, AC side protection-equlres max 20A per branch circuit O137AI+T Dai-Ai -aa 2-3 �dzr i 5-5F-a-?: !C5:? US-72-2-'1JS MD Peak output power 240 V1 290 VA Maximum continuous output pourer 230 dA 280 VA Nominai voltage/rangez 240 v/211-26"V 208'v(1m)!183-229 d 2"0 v`/211-26A v 208 V(I 0'/183-229 V Nominal output current 0 96 A 1 ii A 1 1 7 A 1 35 A Nominal frequency 6C Hz 60 Hz Extended Frequency range 47-68 Hz 17-68 Hz Power factor at rated power z 0 t 0 Maximum units per 20.4 branch circuit 16(210 VAC) i3(240 VAC) 1a(single-phase 208 VAC) 11 (single-onase 208 VAC) Overvoltage class AC port III III AC port backfeed under smcle fault 0 A 0 A Power factor(adjustable) 0-7 leading- 0 7 lagging 0 7leading - 0 7 lagging F51C:ET 07 @240 V @208 v (10) @240 V @20$V(10; CEC weighted efficiency 97 0% 96 5% 970% 96.5% `4ECH.VVCAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4°5 to 100%(condensing) Connectortype (MCA orAmphenol H41-MA Dimensions(wxH xD) 219 mm x-191 mm x 379 mm(without bracket) Weight 1 5 kg(3 3 lbs) Cooling natural convection-Ivo fans Approved for wet locations Yes Pollution degree PD3 Environmental category!UV exposure ra,ing Outdoor-NEMA 250,type 6(IP57) Commumcaaon Power line Monitor'ng Enughten Manager anc MyEnllghten monitoring options �ompaubie with Enohase iQ envoy Compliance JL 62109-1,UL"741/IEEE154_,FCC Part 15 Class 8 !CES-0003 Class Es, CAhi/CSA-C22 2^.G 1077.1-01 This product is JL Listed as PV Rapic Shut Dower.Equipment and confcrms w!tn NEC-201"anc NEC-2017 section 690 12 and C221-20-'5;Rule 64-218 Rapid Shutdowr.of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions No enforced DCrAC rar:c See the compai•bIl!Ty calculator at endhase com/E?n-us,suiDr)ori/moduie-compa-Libilirkt 2 Nominal•loi,age-ange can be extended oeyonc ,ominal.f r9auired by the ut:iiTy 1�-- •.•'3EP •��_ jaP3 . c ?C' =d� r9:i2,'1_ <,_ ^S•._r-N?rhe L COO- .,- "O1`12SF In,. - z SUNFRAMEMICRORAIL �" UNI RAS SUNFRAMMICRORAL , ` E �® U �lI ,ESS RAIL,MORE PERFORMANCE SOLAR SHOULD 6E SIWIE SUNFRAMEMICRORAIIIM(SFM)isahybrid racking �N �s?f�YIEADINOEEATURE� Nounique MwoeI&oftranrerequlredfor installation A WmmceatesreemoslcmlmmnlNnehaghis32unL35mmdenim&+16mm system including a shuctural front Tunnall' lot fastest STRUCTURAL FRONT TRIMRAIL array alignment and superior aesthetics Minimize totalOusfgnarotmdthereoLnetthern61 ,Portrait,LandscoheorMotetlrnoduloorlentation IA II 111.11„ii,llllt;+ll+Jl;' IPII+e1ltflt?nII:II` launumauenvunlhumol.z1aalip tu%9rtmamwdemminlesill kulhwpcuwanalaI labor with pie assesnbledpal Is,udegiatedbending POST-INSTALL HEIGHTADJUSTMENT ULZIGOLislod.AccelmnouaterhernuststrhlfintAHfret iromenrs hardware and one tool installation Compactpacltaging Its"I;.iUllldl..,lfarllt,Itb[II(iPILIN`Inilvllll, Sia l:rNOlJn:w1111hrSFOSCJI LICtSp1iL'IOICYIIdSIICIIIhJWnLAVI(IIY "'M* LopIll IIIeLgryeitoll]W,>nouJnR alto gmnaanlg into NgnLIsc M25 KMirloUlNltvukl% with few SKUs lowers logistics costs from the SINGLE MODULE ACCESS __J I,n d hl I:IUR tlntA,P 1111 1 full witomnnagementsolution allows pre•manogomantotwirasbeforeloodulernstallatlon warehouse to the milt Patented mounting components Ill 111° ' � I>,Atll 1 rogJgl`Wuc Managuntinlckp,ruWaW I.AUWII$nL'yLn rrlWrpe WIfP IN4ll LtillL Lkll) _ provide post-ur�tall height adjustment and allow far - SmagcumpanaJis,Cmnpaoipackaging&Pro•assenrhlodparts Iemuvat of individual panels fel maintenance SINGLE TOOL INSTALLATION Aflooto teglN.ml6antN,hhuNdNckmgfiteWuleWhsradhtd,altaneonasmglcrmLk QUICK&EA3V ARRAY ALIGNMENT TRIMRAIL KITH SEAMLESS MODULE MOUNTING MIXED ARRAYS•PORTRAIT&LANDSCAPE ORIENTATION AVAILABLE MtPEMOUNT WITH CABLE MANAGEMENT LOGISTICS OPTIMIZED•COMPACT PACKAGING HW SKU'S SIMPLIFIES INSTALLATION ENHANCEO J BUILDER DESIGN/LAYOUT TOOL ON SITE PROOUCTTRAININO COLLABORATION WITH INDUSTRY LEADING INSTALLERS m FIELD TESTED&VERIFIED WORLD CLASS U OUILDFR FOR QUICK&EFFICIENT DESIGN/LAYOUT WITI IIN MMU TES (ASI AND tASY PLRMIT APPROVAL PRODUCT(RAINING WITH PROJECT MANAGEMENI SLRVIGES TO MINIM0 INSFALLAIION LEARNING t;URVI” LE9 PERFORM AE