Loading...
HomeMy WebLinkAbout44103-Z Town of Southold 2/26/2020 o P.O.Box 1179 53095 Main Rd `ay'y0 �10- Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41100 Date: 2/26/2020 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 850 CR 48, Greenport SCTM#: 473889 Sec/Block/Lot: 34.4-1.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/15/2019 pursuant to which Building Permit No. 44103 dated 8/27/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate,is issued to Gwiazda,John&Hooper,Deborah of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 44103 02-20-2020 PLUMBERS CERTIFICATION DATED r Authorized Signature TOWN OF SOUTHOLD a�guFEo�,r�o BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy • o� SOUTHOLD, NY �¢ BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 44103 Date: 8/27/2019 Permission is hereby granted to: Gwiazda, John & Hooper, Deborah PO BOX 185 Greenport, NY 119440185 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 850 CR 48, Greenport SCTM #473889 Sec/Block/Lot# 34.4-1.1 Pursuant to application dated 8/15/2019 and approved by the Building Inspector. To expire on 2/25/2021. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 Bui pector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy -New dwelling$50.00,Additions to dwelling$50.00, Alterations to dwelling$50.00, Swimming pool$50.00, Accessory building$50.00,Additions to accessory building$50.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy -Residential$15.00, Commercial $15.00 (� Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: 850 North Road Greenport House No. Street Hamlet Owner or Owners of Property: John GwiaZda Suffolk County Tax Map No 1000, Section 34 Block 4 Lot 1 .1 Subdivision Filed Map. Lot: Permit No. -I I Date of Permit. Applicant: Scott MaSkln, Sunation Solar Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ 5P0 ' licant Signature Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) I, --non ����\�'��G residing at (Print property owner's name) (Mailing Address) do hereby authorize�� lam_ (Agent) S�7�0S<;LqfflNj to apply on my behalf to the fi- Southold Building Department. (Owner's ignatu (Date) 1AW) (Print Owner's Name) OF SOVry®l Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G • iQ roger.riche rt(C—Dtown.southoId.ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To. Gwaizda / Hooper Address- 850 CR 48 City: Greenport St: New York Zip: 11944 Building Permit# 44103 Section 34 Block 4 Lot, 1.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Sunation Solar Systems In(License No: 33412-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures TVSS Other Equipment 8.88 KW roof mounted photo voltaic system, to include 24-370 W panels with micr inverters,combiner panel,service disconnect(rapid shutdown) Notes. Inspector Signature: Date: February 20 2020 81-Cert Electrical Compliance Form As *sf SO(/jyO6 # # TOWN -OF SOUTHOLD BUILDING -DEPT. °`��oi►rnr '' 765-1802 INSPECTION,4qq3 [ ] FOUNDATION 1ST [ ] ROUGH PLBG. 6 'e' [ ], FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING/STRAPPING [ ] FINAL f' -]' FIREPLACE & CHIMNEY [ ] FIRE-SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] -FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: DATE Z?f INSPECTOR" rG f/ Fisher Engineering Services, P.C. PO Box 30 . Oakdale -New York 11769 Phone: (631) 563-9028 November 1, 2019 Town of Southold Post Installation Certification Subject: Engineer Statement for Solar Roof Installation FEB 2 5 202T Residence: Gwiazda- 850 North Road and Bailey, Greenport Permit No. 4403 r, Installation Inspection Date: 10.31.19 The roof mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the approved plans and is certified by Fisher Engineering Services,P.C.to be in compliance with the minimum requirements of the Town,the 2017 NYS Uniform Code, 2017 NYS Uniform Code Supplement, 2015 International Residential Code (2015 IRC),Long Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code 2014, and the provisions of ASCE 7-10. NE1y r0 Sincerely, Jj T : William G. Fisher, P.E. Licensed Professional Engineer Architectural Design-Residential-Light Commercial Additions-Extensions-Conversions Construction Estimates/Oversight-Expediting-Inspections Bunch, Connie From: Nadine Valoy <nvaloy@sunation.com> Sent: Friday, February 21, 2020 9:47 AM To: Bunch, Connie Subject: Re: [SPAM] - RE: Gwiazda, John They customer was home. I advised the homeowner someone needed to be there. I attached some pictures of the outside equi ment. y \ YY•I Y t r 4. 9 x- i .w 1 r A �f for 1 1 fr/ .i, s s Nadine Valoy Nadine Valoy Processing Coordinator,EXT. 304 SUNation Solar Systems, Inc. 171 Remington Blvd Ronkonkoma, New York 11779 Phone: (631)750-9454 Fax: (631)750-9455 Like Us on Facebook for all your SUNation News and Events! Follow us on Twitter Follow us on Instaaram 3 FIELD INSPECTION REPORT DATE COMMENTS -r,`ti ZRI FOUNDATION(IST) Q -------------------------------------- FOUNDATION(2ND) z o IL ROUGH FRAMING& 41 PLUMBING j � 0 r INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITI NAL OMMENTS 0-00 8' V"S f - R-0 m QPb O z H Cq d �J TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 ( Planning Board approval FAX:(631)765-9502I�'�b Survey SoutholdTown.NorthFork.net PERMIT NO. ( Check Septic Form N.Y.S D.E.C. Trustees C.O.Application Flood Permit Examined 20_6 Single&Separate Storm-Water Assessment Form Contact: Approved 20 J Mail to:SUNabon Solar Systems,Inc Disapproved a/c 171 Remington Boulevard,Ronkonkoma NY 11779 Phone:(631)750-9454 (� I•� zpjtat1lom' 1 t P I-;'2b �- I" Buil ' nspector AUG 1 5 , APPLICATION FOR BUILDING PERMIT RT ' BST T om `. Date ,20 –1 INSTRUCTIONS IV— a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within-12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. ignature o licant or name,if a ation) SUNation Solar Systems,Inc 171 Remington Boulevard,Ronkonkoma NY 11779 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,,general contractor,electrician,plumber or builder SU Nation Solar Systems,Inc-Contractor Name of owner of premises John Gwiazda - - (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer Scott Maskln-President (Name and title of corporate officer) Builders License No.44104-H Plumbers License No. N/A Electricians License No.33412-ME Other Traders License No. 1. Location of land on which proposed work will be done: 650 North Road Greenport House Number Street Hainlet County Tax Map No. 1000 Section 34 Block 4 Lot 11 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Residence b. Intended use and occupancy Residence with addition of Solar Panels Y 3. Nature of work(check which applicable):New Building Addition_[]_Alteration_� Repair Removal Demolition Other Work aoaraaoe� (Description) 4. Estimated Cost $30,097 00 Fee $200 00 (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law,ordinance or regulation?YES_NO X 13.Will lot be re-graded?YES_NO X Will excess fill be removed from premises?YES_NO X 14.Names of Owner of premises John Gwrazda Address 550 Norrh Road,creeaportNY 119"phone No. 516-446-6050 Name of Architect-11,am G Fisher Address 509 SaywIe Blvd,Say0le,NY 11782 Phone No 631-786-4419 Name of Contractor sUNanon solar systema,Inc Address 171 Rem-11 8Nd,Re knkeara NY 11oPhone No. 631-750-9454 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO X *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland?*YES NO X *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO X *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Scott Maskrn-President-SUNatron Solar Systems,Inc. being duly swom,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief,and that the work will be performed in the manner set forth to the application filed therewith. Vo br�-to before me t ' day of 20n_ Notary Public Signature of Applrc -VICTORIA M. WALKER NOTARY PUBLIC-STATE OF NEW YORK No. Ol WA631 9756 Qualified in Suffolk County My Commission Expires February 23,0026 Scott A. Russell ,�'6; u 'r�G ST01K1�WWA\T]E K svPERvisoR U MANAGEMENT SOUTHOLD TOWN HALL-P.O.Box 1179 0 53095 Main Road-SOUTHOLD,NEW YORK 11971 Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOZES TIUS PROJECT INVOLVE ANY OF THE FOLLOWING. Yes No (CHECK ALL THAT APPLY) ❑d A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑[� B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑� C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. [:]EJD. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑[I� E. Site preparation within the one-hundred-year floodplain as depicted on FIRM Map of any watercourse. ❑ F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT (Property Owner,Design Professional,Agent,Contractor,Other) S.C.T.M. #: 1000 Date District NAME Scott Maskin -� _�J_ t.k Section Block Lot FOR BUILDING DEPARTMENT USE ONLY**** Contact Information 631--l-5 - rnd�-N.mb<d Reviewed By: Date: Property Address/ Location of Construction Work: — — — — — — — — — — — — — — — — — 850 North Road Approved for processing Building Permit. Stormwater Management Control Plan Not Required. Greenport NY 11944 Stormwater Management Control Plan is Required. (Forward to Engineering Department for Review.) FORM # SMCP-TOS MAY 2014 sorry - Town Hall Annex Telephone(631)765.1802 54375ad P.O.Box179 'tom' er' rCj' B�I�Ch81 fW11IS00tl�dt "R 't!S Southold,NY 11971.0959 FEB 2 1 2020 BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLtCAT_0Nl' rtOR ELECC11Al�'1NSPEC+ ,10 vj REQUESTED BY: ,utT \( • - - ov Date: T �C��2C�2 v Cottpany Name: SUNation Solar:,S,y 'tams, Inc. Name; Scott Maskin tcense No 33412-ME - � Address; - ,_ - -_`-, ____ _- --- - 171�Rer)iitlgton;p vd, Ronkonkoma, NY 11779 l � PhO�e'�NO. �-- - -_ 631-750-9454 - ==-- --�== _--�------- :. -- - -_ :---_----- -------- - " JOBSITE INFORMATION:. (*Indicates required information) - *Name: *Address: *Cross Street: D, *Phone No.. =l`' 5 5 .. Permit No.: ,1o3 Tax-Map District: F _1000 Section:- �;'- - Block: -�- - - -- . Lot: ' *BRIEF DESCRIPTION OF WORK(Please Print Clearly) F (Please Circle All That Apply) *Is job ready for inspection: 1 Rough In Final *Do-you need a Temp Certificate: a Temp Information(If.needed) > *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other K *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: pAYiUIE NT DUE.INI-THskPPLICR' -- __ - M-1.0 - B24Request for Inspection Form i �• '•i 1 �.'_ � -��dCA a '.t,, _V�S� '�.-'.;•'. ..., n_•.i•.,T�•i a''' .f'rY �'��-� t•':irY,. t'• �. `. e, 4�• J _ - t wrC� .� y•��-tYat,., _S'.�t�.L,�',Y,t.dr'fr��.t� .t.•:,t•�•� '• `„ i'• •rte• ••r `:•., .:tr' ?' b •, ,` :` -'! i ;': -^ -`^ .. :. •,n; .•:":"' -,� ;.,.- n +` 9-.'.? ••v" fit:.�',y*. 1 'r v f, wf :y. 'c A5,...:fit{ 1 n 4l 5 't J :« •1;_ tt •`"r;'t •i,:-a. r W ,`.+ '.l�k f ::ti. � c� •f •vt �.y. ,i, '4t Y.1� `- i•(�`a+'•,�• 5 �t.` J� ',4biv�waf• -ry - - C:R\ n, �"y '+ ;?;•.i;i:w'i -• .•mss ��•• � ". ..{y. l>'O. _t . j1�5�! '�•`'••, •' •:-�•'':w`y. i ,. .��- �-,� •� t - W. �. '. ��fyy::tom'•" ti. .•"?',..... .�_.: � �:.- r :' t�t •. � �}`•..:Q.....�: r'f.til ,i:--yrs:' 'r � :. f. O� .'•1 �'r'..,� ','.`+e".n`�CJ°f:-+73;•••cam`, - - .� .� _ .j'J •moo ,a ;.� .,. :�;`r��:` • � ,may 5.73�� �'' •• `. .; ;�:.=c,,�_ fma a,,AL7t9A5ICM OL ADDIFIOr M�!` D� `ROPE• O 1106.=v Is A VIOLATION vw "A' ' ' • _ IdfOl2.7xOD of nfe,Htw•. ' SUR�E,Y!E�'FOR:' GOnfsm,UOs L w+ MA rOX,S fO$tAL0s D 1UxAGIHO Al T A/Vz7 U.tLp55tO'SiAI:HAtI I*'C CmIltu - y .. ..>• IOM A VAUO,IUI con• _ - A T i• ^'7- ou CUAwmn=ICAC; V �IML RlIIY1T - - -, '••.•• :; ••'• ItPLOMK1TO'Lf-0DA ph$=u`AOWDd 55C*.� Gf?EE,NPOR., T /V. Y. •t-. _ .,: .f:= �.• tmt rpypAf:I.2i9viS7Y1Dif _. _ - r - ..5 , ::':'f:,•, tOJ1fNG US};7lfffpft f:T,D 1-0 4 AND _ '...•- _: ; •-:•.•••• •• ,'•�:~ ;';''__ =' -71 SGGcIe 5�0 � _ /" • � .TY"lB •�t?a3GlYL�41.Gea"=�?f'YI gYlt Y►.�-f-„ japA • _ _ '._ . ' ` _ ,;q 5�strlY�c�ed�/JQv��lbar�-3��rb�7,.7."• • ��///' 1 / p 1 � I«i•••1 „SLIT.To�K .`COGCY17�, 7"Ct1l;•131LQ1. •rw- ''>;"• _'�:•':',�,.�•��G+'.r`_ *!;' •�'�=�+i4`'� =c�es�' Kai:'� -r'•p � `f-i000 -=� -- �$ v� :� f'�!� � �-'x. :Sea an _ � - :. I,`v i .:'�.... .,�J..t�4�-2.�•tt. .����ia�.�%2:X!:I`.�..�t � ,l ^•�. 'B•'.f`i'r' r t,_ --J •.t:i. _ . ...:,:{%. .. '...K' �,iS.-�C•:,;.'ei�:: :rL��tsrzy 2•`_ ...L'<r.�ti'r _ a New York State Insurance Fund Workers'Compensation&Disability Benefits Specialists Since 1914 199 CHURCH STREET,NEW YORK,N.Y.10007-1100 CERTIFICATE'OF WORKERS' COMPENSATION INSURANCE DD AAAAAA 753118816 SUNATION ROOFING SERVICES INC 171 REMINGTON BOULEVARD ❑i RONKONKOMA NY 11779 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z2160 670-2 482687 01/01/2019 TO 01/0112020 3/12/2019 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://W M.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR' INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. -NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING' VALIDATION NUMBER:453899859 U-26 3 9 i I Show Receipt Detail Page 1 of 2 I a ti RECEIPT Suffolk County Government SUFFOLK COUNTY LABOR, LICENSING&CONSUMER AFFAIRS P.O. BOX 6100 HAUPPAUGE, NY 11788 James M Andrews Application:ME-33412 Application Type:ConsumerAffairs/Licenses/Master Electrician/NA Address. Owner Name:SUNATION SOLAR SYSTEMS INC Owner Address:171 REMINGTON BLVD RONKONKOMA,NY 11779 Application Name: Receipt No. 160594 Payment Method Ref Number Amount Paid Payment Date Cashier ID Received Comments Check 27486 $400.00 06/04/2019 CLEMON RENEWAL Owner Info.: SUNATION SOLAR SYSTEMS INC 171 REMINGTON BLVD RONKONKOMA, NY 11779 Work Description: Suffolk County Dept.of I; Labor,Licensing&Consumer Affairs j MASTER ELECTRICAL LICENSE Name SCOTT A MASKIN I Business Name This certifies that the SLINATION SOLAR SYSTEMS INC bearer is duly licensed by the County of suffolk License Number.ME-33412 Fras+k,Narde" Issued: 06124/2003 Commissioner Expires: 0610112021 I https:Havprod.suffolkcountyny.gov/portlets/fee/reeciptV iew.do?mode=view&autoPrint=fals... 6/4/2019 1 I SUFFOLK COUNTY DEPT OF LABOR, LICENSING 8 CONSUMER AFFAIRS _ HOMEIMPROVEMENT t CONTRACTOR LICEN, RAW 13 I f "Irk SCOTT MASKIN This certifies that the 6umE"mm'6 bearer is duly SUNATION SOLAR SYSTEMS INC licensed by the Lk— b. cn*tiNm County of Suffolk 03106/2008 44104-H 03/01/2020 Fisher Engineering Services, P.C. 509 Sayville Blvd • Sayville •New York 11782 Phone: (631) 563-9028 August 14, 2019 Attention: Building Department Subject: Engineer Statement for Solar Roof Installation Gwiazda Residence- 850 North Road, Greenport,NY 11944 I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector system (photovoltaic system) and its installation satisfies the structural roof framing design load requirements of the 2015-International Residential Code and the 2017-New York State Uniform Code Supplement, Long Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code 2014. I have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic system for the above residence meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting, the rails shall be securely anchored to the rafters utilizing lag screws that have been designed for wind speed criteria of 130 mph and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geographic design criteria are not applicable to this solar installation. The installation shall be in accordance with the minimum requirements certified by this letter. The existing roof rafters are 2"x8" on 24" c.c., with actual spans of I V-0", with plywood roof decking and one roof shingle layer on the house as shown on the drawings. There are no structural modifications planned or required for the existing roof. I hope that this letter serves and meets with the approval of the Building Department. Sincerely, OF NEiy r,J William G. Fisher,"Pt. Licensed Professional Engineer i-- Architectural Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections LG370Ql C:V5 370W LG Neon R is LG's highest efficiency module in the market and provides r �� world-class performance.The unique,back-contact cell structure eliminates electrodes on the front which maximizes the collection of light and Improves overall reliability LG Neon R features an enhanced warranty, _•� Improved aesthetics on residential roof-tops,and the highest performance -•• and durability under real-world conditions • . COOS C ♦ ♦ 1 Features Aesthetic Roof Extended Product Warranty 3 LG NeOW1 R has been designed with yy� LG has extended the product warranty aesthetics In mind the lack of any of the NeON®R to 25 years,which Is top electrodes on the front creates an level In the Industry. Improved,modern aesthetic Better Performance on a Sunny Day "" More generation per square meter LG NeON01 R now performs better on Yt The LG NeON®R has been designed to sunny days,thanks to Its improved significantly enhance Its output,making temperature coefficient It efficient even in limited space. About LG Electronics LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV pane's and energy storage systems'he company first embarked on a solar erergy source resea*ch program in 1985,supported by LG Groups vast experience in the semiconductor,LCD,chemistry and materials industries In 2010,LG Solar successfu.ly Solar released its first MonoXID series to the market,which s now available in 32 countries The NeGNa(previous MonoXO NeON),NeONO2,NeON®2 BiFacial won the"Intersola Lra AWARD'in 2013,2015 and 2016,which demonstrates LG's leadersrvp and innm,ation in the solar industry LG NeONOR LG370Q1 C-V5 General Data Electrical Properties(STC*) Celt Properties(MateriaWype) Mon ocrystallme/N-type Model LG3700IC-VS Cell Maker LG Maximum Power(Pmax) [W] 370 Cell Configuration 60Cells(6x10) MPPVottage(Vmpp)_ (V] , 370 Module Dimensions(LxWx H) 1,700mm x 1,01 6mm x 40mm MPP Current(Impp) [A]', 1001 Weight 17 5 kg open Circuit Voltage(Voc,*59.) M 428 Glass Crhickness I Material) 2 8mm/Tempered Glass with AR Coating 5hortCacuit Current(lsc ts%) [Al ; 1082 Backsheet(color) White Module Efficiency [%] 214 — Frame(MateriaQ Anodized Aluminum PowerToletanre N ; 0-+3 Junction Box(Protection Degree) IP68 with 3 Bypass Diodes •STC(Standard Test Condition)Irradiance 1000 W/m',Cell temperature 25°C,AM 15 Cables(Length) 1,000mmx2EA Connector(Type/Maker) MC 4/MC Operating Conditions 6peratingTemperature [°C] j -40—+90 Certifications and Warranty Mammum System Voltage IV) 1,000 IEC 61215-1/-1-1/2 2016,IEC 61730-1/22016, Mawmum5enesFuse Ratmg [A) 20 UL 1703 MechamcalTest Load(Front) [Pa/psf) 5,4001113 Certifications ISO 9001,ISO 14001,ISO 50001 MechanicatTesttoad(Rear)- (Pa/pso 4,000/835 OHSAS 18001 'Test Load-Design x Safety Factor(1 5) salt Mist Corrosion Test IEC 61701 2012 Seventy 6 AmmoniaConosionTest IEC 627162013 Packaging Configuration Module Fire Performance Type 1 Number of Modules per Pallet _ [EA] 25 Fire Rating' Class C(UL 790) Number of Modules per 40ft HQ Container [EA] 650 Product Warranty 25Years�— 'Packaging Box Dimensions(LxWxH) Y [mm] 1,750xl,120x1,221 Output Warranty of Pmax LinearWarranty" _ Packaging Box Gross Weight _ (kg] 473 •1)1st year 98%, 2)After 1st year 03%annual degradation, 3)25 years 906% Dimensions(mm/inch) Temperature Characteristics NMOT* (°c] 44±3 Pmax _ [%PCI_. 030 1016.0140.0 Vol: [ °C -024 976.0/3854 �.n Ise [9o/°C) 0037 0ra,n Holes ��- 175 0/6 9 40 0/1 57 •NMOT(Nominal Module Operating Temperature)Irradiance 800 W/m2,Ambient temperature 20°C, P- 4. %n. Wind speed 1 m/s,Spectrum AM 15 6ro�nd ny He es MOtn,.in0 Hole=_ i nit nn RnF Electrical Properties(NMOT) Model LG370QIC-VS Maximum Power(Pmax) [W3 279 MPP Voltage(Vmpp) [V) 369 ro °av MPP Current(tmpp) [A] ' - _ 755 - o.c i Open CircuitVoltage(Voc) M 403 o mo m g R_ shortcircultCurre t(Isc) [A) 871 Ol 01 06 De O: 0. IN Curves 5 12 10DDW 16 600N 0 8 ....„„��,` o 900W N 4 ........, ... \ix 2 0.0 100 200 300 40.0 Voltage M LG Electronics Inc Product specifications are subject to change without notice [oil M[is] SC'tar Business Division LG370Q1 C-V5 US Ver01 pdf (a 2000 Millbrook Drive LG Lincolnshire,IL 60069 Life's Good wv wig-solarcom ©2019 LG Electronics All rights reserved ��, Enphase Ifs System Component List IQ7-60-2-US IQ7PLUS-72-2-US IQ7X-96-2-US Enphase IQ 7 MicroT",250 VA peak power, Enphase IQ 7+MicroTm 295 VA peak power, Enphase IQ 7X MicroTM,320 VA peak power, MC4 DC connectors,female AC connector MC4 DC connectors,female AC connector MC4 DC connectors,female AC connector Compatible with 60-cell PV modules Compatible with 60-and 72-cell PV modules Compatible with 96-cell PV modules IQ6-60-2-US/IQ6PLUS-72-2-US ENV-IQ-AM1-240 M J sa Enphase IQ 6 MicroTP°",compatible with 60-cell Enphase IQ EnvoyT'°',single- PV modules,240 VA peak power, phase,metered Revenue-grade Enphase IQ 6+Micros-n,compatible with 60- accuracy(ANSI C12.20+/-0 5%) and 72-cell PV modules,290 VA peak power with calibrated solid-core CT MC4 DC connectors,female AC connector Compatible with IQ Micros only p` a Accessories for IQ Combiner 3 t ,; -BRK-10A-2-240 Circuit breaker, t `s 2 pole,l OA,Eaton BR210 BRK-15A-2-240 Circuit breaker, `d ¥I6 $`q•, Y 2 pole,15A,Eaton BR215 BRK-20A-2P-240 Circuit X-IQ-AM1-240-2 M X-IQ-AM1-240-3 M breaker,2 pole,20A,Eaton BR220 ENV-IQ-AM3-3P Enphase IQ Combiner+TM with Enphase IQ Combiner 3T"'with IQ ( Enphase IQ Commercial EnvoyT"^, IQ Envoy,80A,single-phase, Envoy PCB,80A,single-phase, XA-PLUG-120-3 Accessory three-phase,metered revenue-grade production revenue-grade production receptacle for Power Line Carrier Revenue-grade accuracy(ANSI metering.Compatible with metering Optional (EPLC-01) C12 20+/-0 51/o)with split-core CT Enphase IQ Micros and IQ Battery consumption monitoring -XA-ENV-PCBA-3 IQ Envoy Compatible with IQ Micros only Optional consumption monitoring Single-stud mounting PCB.For replacement only CT-200-SPLIT CELLMODEM-01 /-03 EPLC-01 Q-BA-3-1 P-60 Enphase Consumption CT, Enphase Mobile Connect"and Enphase Power Line Carrier Enphase Q Aggregator, split-core current transformer, Mobile Connect+TPn cellular Quantity 2 combines up to three accuracy+/-2 5%for monitoring modem with 5-and 12-year microinverter branches,60A whole-home energy data plans(US,Canada,Puerto Rico, max,includes one Q-BA-CAP. consumption Compatible with Mexico,US Virgin Islands) Compatible with Q Cable. IQ Envoy and IQ Combiner For systems with up to 60 micros c ® ww G PHAS . uk NO IQ6PLUS-B1200-LL-1-US00-RV1 ,ra . BWM-161N-B Enphase IQ BatteryT""With integrated . , Enphase Battery Wall Mount Bracket",' ( IQ6+Micro,280W/1 2 kWh,240 VAC a Size 487 mm(W)x 356 mm(H)/19 2 split-phase,Indoor-residential, In (W)x 14 0 in.(H),accommodates o.,..•,E line-to-line communications _ 16 in battery-to-battery spacing Compatible with grid-tied PV systems Compatible with Enphase IQ Battery using the Enphase IQ Envoy a . z" Q-12-10-240 Q-12-17-240 Q-12-20-200 Q-12-RAW-300 Enphase Q Cable TM for 60/72 Q Cable m for 60 cell 1 7m Q Cable TM for 72 cell 2 Om RAW Q CableTm is one(1)spool cell 1 Om portrait module pitch landscape module pitch landscape module pitch at 300m/984 ft length 12 Connector pitch is 1 3m 240 Connector pitch is 2 Om 240 Connector pitch is 2 3m 200 AWG,no connectors included male connectors plus two(2) male connectors plus two(2) male connectors plus two(2) bonus link connectors. bonus link connectors bonus link connectors MM.. Q-TERM-10 Q-SEAL-10 Q9- - EFM-35MM/EFM-40M Enphase Q Cable Terminator Enphase Q Sealing Caps, Enphase Branch Aggregator Enphase Frame Mount for Cap for Q Cable ends Center female sealing cap for unused Q Cap,male sealing cap for mounting Enphase feed requires two(2)per Cable connectors Pack of 10 unused Q Aggregator Microinverters to 35 mm or branch Pack of 10 connections 40 mm module frames 4ej^. Q-CLIP-100 Q-DISC-10 Q-DCC-2 Q-DCC-5 Enphase Q Cable Rail Mount Enphase Q Cable Disconnect tool Enphase IQ Replacement Enphase IQ Replacement Cable Management Clip Pack for Q Cable connectors,MC and Adaptor for MC4 DC Adaptor for UTX DC of 100 Amphenol DC connectors,and AC connector (Amphenol)connector module mount Pack of 10 Q-CONN-10M Q-CONN-10F Enphase Male Field-Wireable Connector to Enphase Female Field-Wireable Connector make connections from any Q Aggregator to make connections from any Q Cable �i open connector Requires MC4 crimpopen connector.Requires MC4 crimp am tool PV-CZM-18100,-19100,or-22100 for tool PV-CZM-18100,-19100,or-22100 for connections to Q Cable or RAW Q Cable connections to Q Cable or RAW Q Cable For more information visit www.enphase.com or call (877)797-4743 ENPHASE. 0 2018 Enphase Energy All rights reserved 9-10-18 SERIES 100 ............... ® � - - - The SnapNrack line of solar mounting systems is designed to reduce total installation costs. The system features :. F technical innovations proven on more ° than 20OMW of solar projects to simplify installation and reduce costs. *p Flashed L Foot Simplified SnapNrack Series 100 Flashed L Foot Kit is an innovative , ora solution to provide a long lasting watertight seal over the life of the system. The Flashed L Foot provides a d , single fastener flashed to an attachment composition Flashed L Foot in 3 Simple.Steps: shingle roof with no required cutting of shingles The L D Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base 3 3) Set the:flashing and attach the L l=oot • 1" slotted bolt connection • 1" spacers available for increased adjustability • Clear or Black anodized aluminum components Place'order through your SnapNrack (both available with black flashing) distributor.,which can be found at • No Cutting of shingles www.snapnrack,coM/c6ntact S n a rack- f Patent Pending 1 # a e •, Flashed L Foot Kit Assembled(1'spacer sold separately) Flashed L Foot Kit Parts(1'spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions SNAPNRACK CHANNEL NUT SNAPNRACK 92 DEGREE L-FOOr,CLEAR _ 5/3618 FLANGE NUT 5/1BOLT WRH r SPLF IT LOCK CKK WASHER SNAPNRACK COMPOSITION FLASHING z o0 • \ 393 `SNAPNRACK IF.BASE 88 SnapNrack Flashed FOot Technical Data Patent Pending Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 0.16 lbs Design Uplight Load 200 lbs Uplift Design Ultimate Load 1,000 lbs Uplift Warranty 10 Year material and worksmanship S.9 a rack-r. rF c,r 1 C >. 1 (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks ©2013 by SnapNrack PV Mounting System All rights reserved S E R-,I",E S 10 0- U,L" • W-L ,AOL- id-1 ........... :,I*) Lk ............ .... .......... The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive u -� down costs and improve installation quality on more than 350 MW of solar .w. - - ° ' ... installations. ;r Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System = is an efficient, visually appealing, photovoltaic (PV) module installation system Series 100 UL is Listed to the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional ? 1)Go to.the online Series 100 Configuration grounding hardware. The System's components provide Tool.(configure.snapnrack:com)and select an adequate bonding path which has eliminated the Yes",for UL 2703 Listed need for grounding lugs and washers at each module, 2) Identify Site Conditions(Array Tilt, Building and bonding jumpers between splices.The UL 2703 �- , Listing ensures that SnapNrack partners can provide Height, Roof Type, Wind and Snow Loads) t the best in class installations in quality, safety, and 3)Build array in the online Configuration i efficiency. Tool and automatically generate a Bill of Materials, • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules - for additional.savings • Rail splices bond rails together, no rail dumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules VL LISTED PV Mounting System Patent Pending 2703 Stamless Bolt with Stainless Steel SnapNrack Bonding SnapNrack Standard Rail Bolt with Split- Slice Insert Split-Lock Washer p Lock Washer SnapNrack Bonding SnapNrack Adjustable End SnapNrack Splice Clamp Top Bonding Base Mid Clamp SnapNrack —SnapNrack BondingSnapNrack Bonding Adjustable End Mst�,nle�s Bond Clamp BottomBondingChannel Nut Bonding Stainless Hardware with Bolt with r%r�a Channel Nut Split-Lock Washers Split Lock SnapNrack Bonding Sna Nrack Bonding Washer Adjustable End Clamp p g SnapNrack Bonding Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6 AWG - Copper Wire SnapNrack Ground Lug Assembly (ONE REDUIRED PER ROW OF MODULES) SnapNrack Bonding Universal End Clamp(UEC)Wave UEC Pull Strap UEC Wedge � Stainless Steel Bolt with Flat Washer SnapNrack Bonding Universal End Clamp SnapNrack Bonding Standoff Clamp Assembly SnapNrack- Serrated Stainless � SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Rain Collar Channel Stainless Serrated Stainless-- Nut Flange Nut Steel Flange Bolt SnapNrack I Stainless SnapNrack n 92 Degree Flange Mill Finish L Foot Bolt Standoff SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff SnapNrack Base(1-Hole SnapNrack Base Shown) , SnapNrack — L Foot Metal Roof Mill Finish Flashing Base Assembly L Foot Base SnapNrack Bonding SnapNrack Bonding J SnapNrack Metal Standoff Assembly L Foot Base with Flashing Roof Base with Bonding L Foot SnapNrack • • UL Technical Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum • Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with Integrated bonding features Calcs.&Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per Individual row of modules) Warranty • 10 Year material and worksmanship(download full details at snapnrack.com) S n a p,,A rack E_ ° (877) 732-2860 www.SnapNrack.com i Printed on recycled paper using soy based inks ©2015 by SnapNrack PV Mounting System All rights reserved I APPROVED AS NOTED DATE: a B.P.# D FEE: d° BY: NOTIFY BUILDING DEPARTMENT AT 765-1802 '8 AM TO a PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF �FH6t�BA- `-soffm61'D Tovvm 1 BOARD tO�'MCD16WN-TeSTEES OCCUPANCY OR OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY ELECTRICAL INSPECTION REQUIRED r • UTILITY METER- OF NES, PLAN KEY SERVICE DISCONNECT- FRONT OF HOUSE-FAONG STREET.DRIVEWAY G MAIN SERVICE PANEL- PV-1 SITE PLAN WIFI ROUTER- WIFI v f A-1 PARTIAL LAYOUT VENT PIPE- ® c INV *- — INVERTER- s f x , 5 (EXT) __ .; ,, �"f..k A-2 ROOF ACCESS PLAN PANEL PHOTOVOLTAIC- SSS U« ` s4 r = ~, ,,,;,,• SFA No 07 9 A-3 ENPHASE CIRCUIT DIAGRAM AC DISCONNECT- ® i SUPPLY SIDE CONNECTION- ELECTRICAL ONE LINE ��FfSS 10 E-1 SENSE MONITOR-FER DIAGRAM L-1 LABELING SCHEMATIC EV CHARGER- EN RaDF FISHER ENGINEERING SERVICES,P C AOCE99 ., EXTERIOR LOCATION- � 509 SAYVILLE BLVD SAYVILLE.NY II152 G-1 PHOTOS IST FLOOR LOCATION - G-T) = LGEN9E N0 014659/631-196-4419 BASEMENT LOCATION- w GARAGE LOCATION SUNation ROOF ` - .I,' AALTERNAATT E,. VENTILATION°a 18" � SUNATION SOLAR SYSTEMS £ , -_' III REMINGTON BLVD vvvvv RONKONKOMA NY 11�-19 n YSERDA NTAI INSSTALLER ROOF STRUCTURE 4355 ALTERNATE VENTILATION-IS": vvvvvv h NUMBER C x CUSTOMER INFO RAFTER / SPACING 2" X 8" 124" O C GWIAZDA RESIDENCE ACTUAL SPAN.11'-0" AC E99 AG ss 850 NORTH ROAD RIDGE I9-1" b 96- GREENPORT 11944 SHEATHING-PLYWOOD PHOTOVOLTAIC JOB NUMBER COLLAR TIES-N/A MODULE ;9844 f .. TYPE 1 LAYERS ARCH ASPHALT/I DATE RAFTER 2"X 5" /24" O G (24)PV MODULES EXISTING INTERIOR RAIL JOB NOTES BEARING WALL I PLEASE USE 48"SPACING DUE TO WIND EXPOSURE AND PITCH ACTUAL SPAN SOFFIT FULL HOUSE-ROOF PLAN EXTERIOR WALL "� SCALE- N.T.S. ROOF SECTION(TTP) SCALE N T S. FASTENER REQUIREMENTS BUILDING REVIEW NOTE NOTES TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE I THIS PV SYSTEM HAS BEEN DESIGNED TO MEET ALL w TOTAL ARRAY AREA=516 SF ENCLOSED DOCUMENT FOR MINIMUM ACCEPTABLE CURRENT AND APPLICABLE FIRE PREVENTION WIND LOAD ASCE 10(SEE CALCULATIONS, THIS SHEET)41.5 PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SETBACK PATHWAYS PER THE 2015 IRC SECTION PSF MAX SPECIFIED IN THE BUILDING AND/OR RESIDENTIAL P324 AND 2011 NTS CODE SUPPLEMENT PROPER LG MODEL MONOX LG3l0QIC-V5 TOTAL UPLIFT=415 PSF X 516 SF=21,414 LBS CODE OF THE STATE OF NEW YORK THIS REVIEW GROUND CLEARANCE,ROOF ACCESS POINTS, ADDITIONAL MATERIALS 310 WATT EA DOES NOT GUARANTEE COMPLIANCE WITH THAT CODE ACCESS PATHWAYS,AND VENTILATION SHALL BE I NIA 66.9"L X 40"W X 1.51"D, IS 58 FT2 FASTENER' THAT RESPONSIBILITY IS GUARANTEED UNDER THE PROVIDED WHERE NECESSARY.AN IN DEPTH 38 58#/MODULE(2 I#/SF)05/2019 LAG SCREW SPEC 203 2, 8/0d (FLAT WASHERS REQUIRED TO BE USED WITH LAG SEAL AND SIGNATURE OF THE NEW YORK STATE DESCRIPTION OF EACH APPUCABLE CODE LICENSED DESIGN PROFESSIONAL OF RECORD THAT REFERENCE AND EXCEPTION FOR ANY CODES IS MODULE (24)LG3T0Q1G-V5 BOLTS) SEAL AND SIGNATURE HAS BEEN INTERPRETED AS AN DEPICTED ON THE A-2 PLATE OF THIS DRAWING OPTIMIZER (24)IQl-PLUS-12-2-US LAG BOLT WITHDRAWAL VALUE, 5/16 DIA,266 LB/IN X 2-INCH THREAD DEPTH= ATTESTATION THAT, TO THE BEST OF THE UCENSEE'S PACKAGE BRANCH#1 #1(1 x 12) 5321-5. CAP. EACH BELIEF AND INFORMATION THE WORK IN DOCUMENT IS 2. ROOF SHALL HAVE NO MORE THAN A SINGLE BRANCH#I #1(1 x 12) MINIMUM NUMBER OF LAG BOLTS REQUIRED=21,414 LBS/532 LBS/LAG BOLT=41 • ACCURATE BRANCH#1 reDTOTAL RAIL FEET=168'-0" RAIL FT/ 41 BOLTS=4'-1" J • CONFORMS WITH GOVERNING CODES APPLICABLE LAYER OF ROOF COVERING IN ADDITION TO THE DRAWN BY BRANCH#I rBD SOLAR EQUIPMENT RACKING SNAP'N'RAGK-ULTRA RAIL MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS"X"USE 4'-0" MAX AT THE TIME OF THE SUBEQUIPMENT SHALL BE SUBMISSION EQUIPMENT • CONFORMS WITH REASONABLE STANDARDS OF 3 INSTALLATION OF SOLAR PACKAGE STANDARD FLUSH-MOUNTED, PARALLEL TO AND NO MORE REVISION SYSTEM RATING(DC) 5 SS Kw PRACTICE AND WITH VIEW TO THE SAFEGUARDING THAN(o-INCHES AI5'OVE THE SURFACE OF THE DATE DESIGNER NOTE EST PRODUCTION(AC) 9,842 KWH/YR OF LIFE, HEALTH, PROPERTY AND PUBLIC ROOF I EST PRODUCTION SOURCE AURORA WELFARE IS THE RESPONSIBILITY OF THE LICENSEE 81419 MANGIN FINAL SPECIAL ATTACHMENTS SPECIAL ATTACHMENTS 4. WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF xxxxxx NIA NIA STRUCTURAL STATEMENT 5 ANY PLUMBING VENTS ARE NOT TO BE CUT OR xxxxxx NIA NIA COVERED FOR SOLAR EQUIPMENT INSTALLATION CLIMATIC I GEOGRAPHIC DESIGN CRITERIA - TABLE 8301.20) THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT ANY RELOCATION OR MODIFICATION OF THE NIA NIA THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC VENT REQUIRES AIPLUMBING PERMIT AND scALE WIND DESIGN SUBJECT TO DAMAGE MODULE SYSTEM INCLUDING UPLIFT$SHEAR THE INSPECTION EXISTING RAFTER SIZES � DIMENSIONS CONFORM TO I N.T.S. WIND WIND ICE THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE SPECIAL SEISMIC CLIMATE FROST WINTER AIR MEAN IRC-2015 TABLE 8802 5(1)-RAFTER SPANS MINIMUM DESIGN STANDARDS FOR BUILDING AND TITLE SITE PLAN GROUND SPEED TOPOGRAPHIC WIND EXPOSURE BORNE DESIGN ZONE WEATHERING LINE TERMITE DESIGN BARRIER FLOOD FREEZING ANNUAL SNOW LOAD (MPH) EFFECTS CATEGORY DEBRIS UNDERLAYMENT HAZARD REGION ZONE CATEGORY DEPTH TEMP REQUIRED INDEX TEMP MOUNTING BRACKETS AND HARDWARE MEET OR OTHER STRUCTURES OF THE ASCE 1-10,IRC 2015 EXCEED NEW YORK STATE GORE REQUIREMENTS FOR AND NEW YORK STATE UCS 2011 MOD SEE 20 PSF 130 B YES C 2 G 4A SEVERE 3=0" TO 15 DEG NAPLANS 599 51 THE DESIGN CRITERIA OF THE TOWN HEAVY EXAMINER l Pv 1 li FFF OF NF G. 0 s F� vo .074 A��FfSSION FISHER ENGINEERING SERVICES,F r- 505 505 SAYVILLE BLVD SAYVILLENY 11 82 UCENSE NO 014ZS/631-186-4419 ,S Sa Wion RIDGE ; 4. SUNATION SOLAR SYSTEMS 44'-8" Ili REMINGTON BLVD 16-Il�y" RONKONKOMA NY 11119 NSTAI I E 4.3 �r.,� IN5TALLER VVNUMBER SNAP'N'RACK SYSTEM PHOTOVOLTAIC CUSTOMER INFO (TYPICAL RAIL ACROSS MODULE(TYP) EACH ROW OF ARRAY) GUIIAZDA RESIDENCE (ONLY TWO SHOWN FOR CLARITY) 850 NORTH ROAD ,"SPACING GREENPORT 11544 BETWEEN ROWS 16-2� JOBNUMBER vvvvvvvv 19844 / DATE Q JOB NOTES v IX I NIA vvvvvv 13-8�2 ROOF AREA mu X GUTTER 14-10�' ADDITIONAL MATERIALS I NIA (1) ROOF 152° TRUE; 35° TILT; 5/12 PITCH (24) MODULES PARTIAL HOUSE ROOF PLAN DRAWN BY SCALE: 3/19," - 1, DONATO \\V// REVISION DATE DESIGNER NOTE 81419 MANGIN FINAL XXXX xx N/A N/A XXXX XX NIA N/A XXXXXX N/A NIA SCALE TITLE PARTIAL LAYOUT A- 1 APPROVED BY• • NFA FRONT OF HOUSE FACING STREET,DRIVEWAY of 0 074 F£Ssio FISHER ENGINEERING SERVICES,P c 505 5AYVII 1 9 BLVD SAYAI I E,NY 11162 "ROOF UGE E NO 014659 i 63I-186-44I5 SUN-ation SUNATION SOLAR SYSTEMS III REMINGTON BLVD RONKONKOMA NY 111115 ROOF NYSERDA '�ALTERNATE VENTILATION I INSTALLER ' ' vvvv NUMBER 43 v v CUSTOMER INFO GLUIAZDA RESIDENCE .. 850 NORTH ROAD ALTERNATE-VENTILATION- 19 GREENFORT 11944 JOB NUMBER 19844 VA Y VA Y DATE 'ACESS AC 55 v NOTES I NIA (24)PV mor->ULr=S ACCESS ROOF A ROOF SURFACE WHICH PROVIDES ACCESS TO THE RIDGE OR PEAK OF AN ADJOINING ROOF SURFACE CONTAINING SOLAR PANELS, MODULES OR ARRAYS AND 19 I RELATIVELY FREE OF VENTS, SKYLIGHTS AND OTHER OBSTRUCTIONS AND 2 DOES NOT CONTAIN SOLAR PANELS,MODULES OR ARRAYS, OR 19 A SINGLE RIDGE ROOF WHERE THE TOTAL EDGE WIDTH OF THE SOLAR PANELS, MODULES OR ARRAYS DOES NOT EXCEED 33 PERCENT OF THE RIDGE LENGTH 83241 ACCESS AND PATHWAYS-ROOF ACCESS,PATHWAYS AND SPACING REQUIREMENTS FOR SOLAR PHOTOVOLTAIC SYSTEMS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R32411 THROUGH R324.16 EXCEPTION(S} I ROOF ACCESS, PATHWAYS AND SPACING REQUIREMENTS NEED NOT BE PROVIDED WHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED, OR WHERE VERTICAL VENTILATION TECHNIQUES WILL NOT BE EMPLOYED DRAW N BY 2 DETACHED NON-HABITABLE GROUP U STRUCTURES KEVIN MANGIN R32414 SINGLE RIDGE ROOFS-PANELS,MODULES OR ARRAYS INSTALLED ED ON ROOFS WITH A SINGLE RIDGE'SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO 36 REVISION INCH WIDE(1514MM)ACCESS PATHWAYS EXTENDING FROM THE ROOF ACCESS POINT TO THE RIDGE ACCESS PATHWAYS ON OPPOSING ROOF SLOPES SHALL NOT BE DATE DESIGNER NOTE LOCATED ALONG THE SAME PLANE AS THE TRUSS,RAFTER OR OTHER SUCH FRAMING SYSTEM THAT SUPPORTS THE PATHWAY XXXXXX N/A NIA EXCEPTION(SX 1. ROOFS WITH SLOPES OF 2 UNITS VERTICAL AND 12 UNITS HORIZONTAL(Iro 6 PERCENT)AND LESS >O(XX XX NIA NIA 2 STRUCTURES WHERE AN ACCESS ROOF FRONTS A STREET, DRIVEWAY OR OTHER AREA READILY ACCES15LE TO EMERGENCY RESPONDERS. XXXXXX NIA N/A 3 ONE ACCESS PATHWAY SHALL BE REQUIRED WHEN A ROOF SLOPE CONTAINING PANELS,MODULES OR ARRAYS 15 LOCATED NOT MORE THAN 24 INCHES(&I OMM) VERTICALLY FROM AN ADJOINING ROOF WHICH CONTAINS AN ACCESS ROOF XXXXXX. NIA . NIA 83241&ROOFS WITH VALLEYS-PANELS AND MODULES SHALL NOT BE LOCATED LESS THAN 18 INCHES(451 MM)FROM A VALLEY SCALE EXCEPTION(S} N.T.S- I ROOFS WITH SLOPES OF 2 UNITS VERTICAL AND 12 UNITS HORIZONTAL(Ia,&PERCENT)AND LESS R32411 ALLOWANCE FOR SMOKE VENTILATION OPERATIONS-PANELS AND MODULES SHALL NOT BE LOCATED LESS THAN IS INCHES(451 mm)FROM A RIDGE OR PEAK TITLE ROOF ACCESS PLAN I WHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED OR wHEREVERTICAL VENTILATION METHODS WILL NOT BE EMPLOYED BETWEEN THE UPPER MOST PORTION OF THE SOLAR PHOTOVOLTAIC SYSTEM AND THE ROOF RIDGE OR PEAK 2 DETACHED GARAGES OR ACCESSORY STRUCTURES A=2 l of NF G. FRONT OF HOUSE — FACING STREET, DRIVEWAY ��ANO04659 sl AC INV y`x f H x „ FISHERNGI YING SERVICES,I SAG SAYVILLE,NY II�H2 (EXT.) DS DG/Q�.: " - - " � '' IJLENSE NO 014659/631-186-4419 seSUHat G SUNATION SOLAR SYSTEMS III REMINGTON BLVD RONKONKOMA N.Y II-nS NYSERDA �3Fpro ACCESS INSTALLER RDOF, — NUMBER CUSTOMER INFO r GWIAZDA RESIDENCE ? 850 NORTH ROAD GREENPORT 11944 �s JOB NUMBER ACCESS 19844 _ ?,,..., .. U - z DATE -'ALTERNATE;YENTILATION8 1 ,9 ' - ; - •a 3 .. .. - NOTES I NIA e..... ......... ........o ......................... CIRCUIT 2 ALTERNATE VENTILATION t YA' Y,,' YA Y r AG E5$ AC SS 3 ,z CIRCUIT I I DRAWN BY KEVIN MANGIN REVISION DATE DESIGNER NOTE XX XxxX NIA N/A XXXxXX NIA NIA XX.XX XX NIA N/A XXXXXX NIA NIA SCALE N.T.S. TITLE ENPHASE CIRCUIT DIAGRAM A-3 1 .'1 ' 1 OF NFIy G O Na 074 silo I UTIL TY FISHER ENGINEERING SERVICES,P C SERVICE 509 5A7VILLE BLVD SAYVILLE,NY 11182 LICEI5E NO 014659/631-186-4419 1 2 11 12 SUPPLY SIDE • CONNECTION M g" V N Mation 11- j t +_a s'+ii shau!c Lr v ENPHASE -= MICRO = --- SUNATION SOLAR SYSTEMS INVERTER _ _ Ill REMINGTON BLVD (TTI.) MODULE J-BOX PLAQUE PLAQUE RONKONKOMA NY II119 (TTP) SERVICE DISCONNECT SERVICEDISCONNECT NYSERDA 10 COMBINER PANEL 2 OF 2 1 OF2r /+ STRING I (ACTIVATES RAPID SECOND DLOCATED NEM TOT INSTAI NUMBERR 4 PV MODULE ATTIC 355 �NtP H�ASMETENV SHUTDOWN) I OeA METER PAN RIMARY DISCONNECT (TYP) 2 LOCATED IN MAIN MAIN I CUSTOMER INFO STRING OF ROOF MOUNTED SERVICE PANEL GWIAZDA RESIDENCE (12)LG31001C-V5 MODULES W/ SOLADECK 2P 20A n (12)ENPHASE 10IPLUS-12-2-US n 850 NORTH ROAD 1 2 MICRO-INVERTERS IN PARALLEL II 12 2P 20Q 2P 20A ENCLOSURE . . . . • . • r1 GREENPORT 11944 SERVICE RATED -------- - ---- 27 20A 40A MIN 60A SENSE Or-ID MIN 22K AIG JOB NUMBER NOLOAOS N N I MOMTORING 1 I ONL7 r DATE -- — — — — --4N SERVICE . _ I EXTERIOR WALL STRING 2 I I NOTES J a b I I N/A I STRING OF CIT)LG31001C-V5 MODULES W/ _ (12)ENPHASE 10IPLUS-I2-2-US EGG ATTACHED- MICRO-INVERTERS IN PARALLEL TO RAIL(TYP) BUILDING GROUNDING ELECTRODE 1 CONDUIT AND CONDUCTOR SCHEDULE TAG DESCRIPTION OR CONDUCTOR NUMBER OF CONDUIT CONDUIT RUN CONDUCTOR TYPE GAUGE CONDUCTORS TYPE SIZE LENGTH 1 ENPHASE Q-GABLE 12 4 N/A N/A 15, 2 HWN-2 10 4 PVC SGH Be 1.25` 20, GC 6 I PVG SGH Be 125" 20' 3 HWN-2 10 4 PvC SCH 80 1.25" le" GG 6 I PVG SGH 80 125" 10, DRAWN BY 4 HWN-2 6 3 PYC SCH 80 125" 2 KEVIN MANGIN GC 6 I PVG SCH 80 1.25" 2 SCALE A' t 5 I-IWN-2 6 3 PVG SCH 60 1.25" E,' N' I .9 TITLE ONE-LINE DIAGRAM 6 EG 6 I PVG SCH 80 0 50° 5' - I 1 1 E- 1 � r