Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
43589-Z
Q�Ft1ICo� Town of Southold 2/10/2020 y P.O.Box 1179 53095 Main Rd Q4k- �0� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41045 Date: 2/10/2020 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 15 Sun Ln, Southold SCTM#: 473889 Sec/Block/Lot: 76.-1-1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated r 3/15/2019 pursuant to which Building Permit No. 43589 dated 3/27/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: "as built"alterations and addtions, including rear entry step, deck addition and outdoor shower(no 'stall),to an existing one family dwelling as applied for. The certificate is issued to Villa,Fernando&Maria of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 43589 k 6/25/2019 PLUMBERS CERTIFICATION DATED 7/1/2019 A M tituck Plutfing ^14ho d Signature ��o�sUF c,r�o TOWN OF SOUTHOLD BUILDING DEPARTMENT s TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 43589 Date: 3/27/2019 Permission is hereby granted to: Scharpf, Walter & Pauline 41 18th Ave Ronkonkoma, NY 11779 To: legalize "as bit" alterations as applied for. At premises located at: 15 Sun Ln, Southold SCTM # 473889 Sec/Block/Lot# 76.-1-1 Pursuant to application dated 3/15/2019 and approved by the Building Inspector. To expire on 9/25/2020. Fees: AS BUILT- SINGLE FAMILY ADDITION/ALTERATION $963.20 CO -ALTERATION TO DWELLING $50.00 Flood Permit $100.00 1: $1,113.20 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: l 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses, or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. /I New Construction: Old or Pre-existing Building: (check one) Location of Property: IV s N LA IVE SO u NO LD ` House No. St'r'eet/ �r1� M Hamlet ' Owner or Owners of Property: 7F'RN AAjbQy I LA '"'AVA k*11 ! Suffolk County Tax Map No 1000, Section ,��1-� �® Block 01 . 00 Lot 00 1 Subdivision wL%T CRS Doi*1WFiled Map. rZ3(7 Lot:_1 A2.Q11� Permit No. 42? Date of Permit. Applicant: f'ff9NAQ/DO WLM Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ V Applicant Signature OF SOUr�®� Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Q Southold,NY 11971-0959 01 • �® roger.richert(a�town.Southold.ny.us U V BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Fernando Villa Address: 15 Sun Lane city:Southold st: New York zip: 11971 Building Permit#: 43589 Section: 76 Block: 1 Lot: 1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: Jim Sage Electric License No: 3635-ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only - Commerical Outdoor X 1st Floor X Pool New Renovation X 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph 200A Heat Duplec Recpt 17 Ceiling Fixtures 7 HID Fixtures Service 3 ph Hot Water ELEC GFCI Recpt 5 Wall Fixtures 11 Smoke Detectors Main Panel 200A A/C Condenser 1 Single Recpt Recessed Fixtures 1 CO Detectors Sub Panel A/C Blower 2 Range Recpt 30A Fluorescent Fixture Pumps Transformer Appliances pW Dryer Recpt Emergency Fixture Time Clocks Disconnect 200A Switches 7 Twist Lock Exit Fixtures �] TVSS Other Equipment 3- Combination Smoke/ CO Detectors, 6 ft of Under Cabinet Lights, 3- Paddle Fans, 30A Hot Water Heater, Range Hood, 4- ARC Fault Circuit Breakers. Notes: Inspector Signature: Date: June 25, 2019 0-Cert Electrical Compliance FormAs Telephone(631)765-1802 'Pay MIlX I.W. P.O.Box 1179 Southold NY.11971-0959 • , VVV,`1 �"�� ! ,.,Y, ,...�..�+LLL]]] 4 �.1 f A BuaDINGDEPARTMENT J�� 'JUL - 2 TOWN OF SOU'THOLD U�� CERT IFIC'AT10N Date: -, /I Building PermitNo. ,43.58 Owner: (Please print) Plumber: o;. v /r1 VJ A , (Please print) , I certify that the solder used,in the water supply system contains less than 2/10 of 1% lead, A (P um ers lgnature) Swom to before me this day of 20 L_I _ ` CHELSEA L, CHALONE Notary Public, State of New York Registration#01CH6287106 Qualified In Suffolk County •Comfni5sigp Expires Aug.5,20 4.1 Notary Public, 1&40\lam ENERGY SPRAY Y S YSTEMS, LLC D DD 9 CUMMINGS AVE,STAMFORD CT 06902 APR 3 0 2019 TEL-(203)536-3388,FAX-(203)321-3096 INSULATION CER TIFICATE TOWN OF SO OLD The following spray polyurethane foam product(s)has/have been installed. Consult International Building Code,chapter 26-Plastic and International Residential Code(IRC)R314 Foam Plastics for specific requirements.The spray polyurethane foam insulation system(s)has/have been installed in accordance with manufacturer's processing guidelines to provide a thermal resistance of: Main House Roof Rafters 2x4 R-24 Closed-Cell Attic Gables R-24 Closed-Cell Framed Exterior Walls 2x4 R-24 Closed-Cell Floor Joists Above Existing Basement+Crawl Space R-21 Closed-Cell Paint—In Basement Ceiling DC315 15-Min Thermal Barrier Paint—In Crawl Space Ceiling DC315 15-Min Thermal Barrier Pack Around AII'Doors&Windows Can Foam Foam Hilti Jobsite Address: 15 Sun Lane. Southold,NY Date of insulation: April 2019 Insulation Contractor: Energy Spray Systems, LLC Installed By:Florjan Shehaj \C') RIED oo RC'Si�� Authorizing Certificate: Aldo Custodio 81A -Post Near Electrical Panel- 0300- N - ENERGY SPRAY SYSTEMS LLQ 9 CU6il MINGS AVE STAMFORD CT 06902 , ENERGY SPRA Y SYSTEMS, ,SLC 9 CUMMINGS AVE,STAMFORD CT 06902 TEL-(203)536-3388, FAX-(203)321-3096 Date- April 2019 *Job Name 15 Sun Lane. Southold,NY *Details Our company Paint with DC-315 Thermal Barrierthe foam left exposed in Basement Ceiling and Crawl Space Ceiling. Spreading rate-For Thermal Barrier AC 377 Appendix X dry mils with a Tip Size of.517 Energ Spray Systems,LLC ENERGY SPnAv svSvEk4S LLC 9 CUMMMS AVE STAMFORD CT 06902 D Ap'14 0 V14 Rcy�T CIA ATF O F NE�� c vi-VD cE 1\+ D--315- . r--Z1 Nt q i N loo>z- 4a1 cF Li N(o/ko0:F= K-2-4 WA LL S G K,�W L 5 fi /}'arLrlAt 5A�1 � F ✓ w f ti * rp- NlAllJ C-vlT -Ll i-IV/N6 "0" 1-lv/N6 ►?.boM /V1f 4�'j BAr=ewlc%,'T 1.� SuNJ 5ovT+4 oLD N y ' 4 RE DIy t 9x,C�-,?oao 1 4 i 410�tt C-45 � Y�vPM tNSUN+n�N V{ IfiGUblil. AU wlk cAAW L S-TA .E UKIV-V1, WOOD �IOW<X.P . ATPLi o;a AFP-iL ESR-3500 I Most Widely Accepted and Trusted Page 2 of 5 3.3 Thermal Resistance: insulation and the interior of the building There is no Icynene ProSeal and Icynene ProSeal LE insulation has a thickness limit when installation is behind a code- thermal resistance, R-value, at a mean temperature of n ed hrmal barrier except as noted in Sections 75°F(24°C)as shown in Table 1. 4.4.2.1,4.4.2. nd 4.4.3. 3.4 Air Permeability: 4.3.2 Applicat on without a Prescriptive Thermal Barrier withC 315 Intumescent Coating: Icynene Icynene ProSeal and Icynene ProSeal LE insulation, ProSeal and I nene ProSeal LE may be installed without minimum 1.4-inch (35.6 mm)thickness, is considered 'r the 15-min thermal barrier prescribed in IBC Section impermeable insulation in accordance with 2015 IB 26 d IRC Section R316.4,when the installation is in Section 1203.3 and 2015 and 2012 IRC Section R806.5 accordance with this section. The Icynene ProSeal (2009 IRC Section R806.4), based on testing in insulation and the DC 315 intumescent coating may be accordance with ASTM E2178. spray-applied to the interior facing of walls, the underside 3.5 Vapor Permeability: of roof sheathing or roof rafters, and in crawl spaces, and may be left exposed as an interior finish without a Icynene ProSeal and Icynene ProSeal LE insulation has a 15-minute thermal barrier or ignition barrier.The thickness vapor Fpermeance of less than 1 perm (57x10-11 kg/ of the insulation applied to the underside of the roof Pa-s-m ) at a minimum thickness of 1.5 inches (38.1 mm) sheathing must not exceed 14 inches (356 mm). The and may be used where a Class 11 vapor retarder is thickness of the insulation applied to vertical wall surfaces required by the applicable code. must not exceed 8 inches (203 mm). The insulation must 3.6 Intumescent Coatings: be covered on all surfaces with DC 315 intumescent 3.6.1 DC 315: DC 315 intumescent coating (ESR-3702), coating at a minimum wet film thickness of 24 mils wet (0.61 mm)[16 mils dry(0.41 mm)]at an application rate of manufactured by International Fireproof Technology, Inc., 1 gallon(3.8 L)per 66.8 square feet(6.15 MI).The coating is a water-based coating supplied in 5-gallon (19 L) pails must be applied over the Icynene ProSeal insulation in and 55 gallon (208 L) drums. The coating material has a accordance with the coating manufacturer's instructions, shelf life of 12 months when stored in factory-sealed ESR-3702 and this report. Surfaces to be coated must be containers at temperatures between 50°F (10°C) and dry, clean, and free of dirt, loose debris and other 80°F(24°C). substances that could interfere with adhesion of the 4.0 DESIGN AND INSTALLATION coating. The coating is applied in one coat with low- 4.1 General: pressure airless spray equipment. Icynene ProSeal and Icynene ProSeal LE must be installed 4.4 Attics and Crawl Spaces: in accordance with the manufacturer's published 4.4.1 Application with a Prescriptive Ignition Barrier: installation instructions,this report and the applicable code. When Icynene ProSeal and Icynene ProSeal LE insulation The manufacturer's published installation instructions and is installed within attics or crawl spaces where entry is this report must be strictly adhered to, and a copy of the made only for service of utilities,an ignition barrier must be instructions and this evaluation report must be available on installed in accordance with IBC Section 2603.4.1.6 or IRC the jobsite at all times during installation. Sections R316.5.3 and R316.5.4, as applicable. The 4.2 Application: ignition barrier must be consistent with the requirements for the type of construction required by the applicable Icynene ProSeal and Icynene ProSeal LE must be applied code, and must be installed in a manner so that the foam using spray equipment specified by Icynene, Inc. The plastic insulation is not exposed. Icynene ProSeal and insulation must not be used in areas having a maximum Icynene ProSeal LE insulation may be installed in service temperature greater than 180°F (82°C), must not unvented attics in accordance with 2015 IBC Section be used in electrical outlet or junction boxes or in contact 1203.3 or 2012 IRC Section R806.5 (2009 IRC Section with rain or water, and must be protected from the weather R806.4). during and after application. Where Icynene ProSeal and Icynene ProSeal LE is used as an air-impermeable barrier, 4.4.2 Application without a Prescriptive Ignition such as in unventilated'attic spaces regulated by IRC Barrier:Where Icynene ProSeal spray foam is installed in Section R806, the insulation must be installed at a an attic or crawl space without a prescriptive ignition minimum thickness of 1.4 inches(35.6 mm).The insulation barrier, in accordance with Sections 4.4.2.1 and 4.4 2.2, is applied to the intended thickness, with the first pass the following conditions apply: being at the maximum thickness set forth in the 1. Entry to the attic or crawl space is only for the service manufacturer's published installation instructions. Where of utilities and no storage is permitted. multiple passes are required, the cure time between each pass is in accordance with the manufacturer's instructions. 2. There are no interconnected attic, crawl space or 4.3 Thermal Barrier: basement areas 4.3.1 Application with a Prescriptive Thermal Barrier: 3. Air in the attic or crawl space is not circulated to other Icynene ProSeal and Icynene ProSeal LE spray foam parts of the building. insulation must be separated from the interior of the 4 Combustion air is provided in accordance with IMC building by an approved thermal barrier, such as /Z-inch- (International Mechanical Code)Section 701 thick (12.7 mm) gypsum board installed using mechanical fasteners in accordance with the applicable code, or an 5 Attic ventilation is provided when required by IBC equivalent 15-minute thermal barrier complying with, and Section 1203.2 or IRC Section R806, except when air- installed in accordance with, IBC Section 2603.4 or IRC impermeable insulation is permitted in unvented attics Section R316.4, as applicable. When installation is within in accordance with 2015 IBC Section 1203.3 or 2012 an attic or crawl space as described in Section 4.4, IRC Section R806.5(2009 IRC Section R806.4). a thermal barrier is not required between the foam plastic 6. Under-floor (crawl space) ventilation is provided when and the attic or crawl space, but is required between the z ESR-3500 I Most Widely Accepted and Trusted Page 3 of 5 required by 2015 IBC Section 1203.4 (2012 and 2009 self-drilling drywall screws spaced 8 inches (203 mm) on IBC Section 1203.3) or IRC Section R408.1, as center around the perimeter and 12 inches (305 mm) on applicable. center in the field. The gypsum board joints must be 4.4.2.1 Attics and. Crawl Spaces - Uncoated: The treated with vinyl or casein, dry or premixed joint thickness of the foam plastic applied to the underside of compound applied in two coats to cover all exposed screw the roof sheathing and/or rafters,or the underside of floors, heads and gypsum board butt joints. A minimum 2-inch- must not exceed 8 inches (203 mm). The thickness of the wide (51 mm) paper, plastic, or fiberglass tape is spray foam insulation applied to vertical wall surfaces must embedded in the first layer of compound over butt joints of not exceed 6 inches (152 mm). The insulation does not the gypsum board require a code-prescribed ignition barrier or coating. 4.6 Exterior Walls in Type I,II,III and IV Construction: 4.4.2.2 Attic and Crawl Spaces-Coated:The thickness 4.6.1 General:When used on exterior walls of Types I, II, of the foam plastic applied to the underside of the roof III or IV construction, the assembly must comply with IBC sheathing and/or rafters, or the underside of floors, must Section 2603.5 and this section, and the Icynene ProSeal not exceed 14 inches (356 mm). The thickness of the and Icynene ProSeal LE insulation must be installed at a spray foam insulation applied to vertical wall surfaces must maximum thickness as described in Table 2.The potential not exceed 8 inches(203 mm) heat of Icynene ProSeal insulation is 2288 Btu/ft2 The Icynene ProSeal and Icynene ProSeal LE insulation (25995 kJ/m2) per inch of thickness, when tested in accordance with NFPA 259. must be covered on all surfaces with 4.6.2 Specific Wall Assemblies: Wall assemblies DC315 at a minimum dry film thickness of 3 mils complying with Section 4.6 must be as described in Table (0.08 mm)[wet film thickness of 4 mils(0.10 mm)]at a rate 2 of 401 square feet(37 m2)per gallon(3.8 L). The coating must be applied over the Icynene ProSeal 4.7 Water-resistive Barrier: and Icynene ProSeal LE insulation in accordance with the Icynene ProSeal and Icynene ProSeal LE insulation may coating manufacturer's instructions and this report. be used as an alternative to the water-resistive barrier Surfaces to be coated must be dry, clean, and free of dirt, prescribed in IBC Section 1404.2 and IRC Section R703.2, loose debris and other substances that could interfere with when installed on exterior walls as described in this section adhesion of the coating The coating is applied in one coat the insulation must be spray-applied to the exterior side of with low-pressure airless spray equipment. sheathing, masonry or other suitable exterior wall substrates to form a continuous layer of 1 inch (25.4 mm) 4.4.3 Use on Attic Floors: Icynene ProSeal and Icynene minimum thickness.All construction joints and penetrations ProSeal LE insulation may be installed exposed at a are to be completely sealed with Icynene ProSeal or maximum thickness of 14 inches (356 mm) between and Icynene ProSeal LE insulation. over the joists in attic floors The insulation must be 5.0 CONDITIONS OF USE separated from the interior of the building by an approved thermal barrier. An ignition barrier in accordance with the The Icynene ProSeal and ProSeal LE spray foam IBC Section 2603.4 and IRC Section R316.5.3 may be insulation described in this report complies with, or is a omitted. suitable alternative to what is specified in, those codes 4.5 One-hour Non-load-bearing Fire-resistance-rated listed in Section 1.0 of this report, subject to the following Wall Assembly: conditions: 4.5.1 Exterior Face: Nominally 6-inch-deep (152 mm), 5.1 The product must be installed in accordance with No. 18 gage galvanized steel studs, spaced 16 inches the manufacturer's published installation instructions, (406 mm) on center, are fastened to No. 18 gage this evaluation report and the applicable code. In the plvanized steel floor and ceiling tracks. One la�+er of event of a conflict between the manufacturer's /2-inch-thick (12.7 mm) Georgia Pacific DensGlass Gold published installation instructions and this report, this Exterior Sheathing is installed parallel to the steel studs report governs. with vertical joints offset a minimum of 16 inches(406 mm) 5.2 The insulation must be separated from the interior of from the vertical joints of the interior Type X gypsum board, the building by an approved 15-minute thermal barrier and the horizontal joints offset a minimum of 24 inches in accordance with IBC Section 2603.4, except when (610 mm) from the horizontal joints of the gypsum board installation is as described in Section 4.3.2 or in attics The sheathing is attached using 11/4-inch long (31.7 mm), and crawl spaces as described in Section 4.4 2. self-drilling drywall screws spaced 8 inches (203 mm) 5.3 The insulation must not exceed the thickness and on center around the perimeter and in the field. Hohmann & Barnard DW-10 brick ties, 6 inches (152 mm) long density noted in Sections 3.2,4.3,4.4,4.5 and 4 6 of by 11/2 inches (38 mm) wide, are spaced 16 inches this report. (406.4 mm) on center vertically on each steel stud, and 5.4 The insulation must be protected from the weather secured using two 15/8-inch-long (41.3)self-drilling screws, during and after application. through 4-inch 0102 mm)-red clay brick [31/2 inches'/2 inches (89 mm) by 2/4 inches (57 mm) by 7 5.5 The insulation must be applied by installers certified(197 mm)], laid in a running bond pattern with Type S by Icynene,Inc. mortar, leaving a nominally 1-inch (25 4 mm) air gap 5.6 Use of the insulation in areas where the probability of between the brick and the exterior sheathing The stud termite infestation is "very heavy" must be in cavity is filled with Icynene ProSeal insulation and Icynene accordance with IRC Section R318 4 or 2012 IBC ProSeal LE to a maximum nominal thickness of 6 inches. Section 2603.9 (2009 IBC Section 2603.8), as 4.5.2 Interior Face: Type X gypsum board, 5/8 inch applicable (15.9 mm) thick and complying with ASTM C1396, is 5.7 Jobsite certification and labeling of the insulation must applied to the interior side with the long edge parallel to comply with 2015 IRC Sections N1101.10.1 and steel studs, and is secured using 11/4-inch-long (32 mm), N1101.10.1.1 (2012 IRC Sections N1101.12.1 and ESR-3500 I Most Widely Accepted and Trusted Page 4 of 5 N1101.12.1.1 or 2009 IRC Sections N1101.4 and 6.7 Report of a potential heat test in accordance with N1101.4.1) and 2015 and 2012 IECC Sections NFPA 259. C303.1.1, C303.1.1.1, R303.1.1 and R303.1 1.1 6.8 Report of a critical radiant flux test in accordance with (2009 IECC Sections 303.1.1 and 303.1.1.1), as ASTM E970. applicable. 5.8 The A and B components of the insulation are 6.9 Reports of tests in accordance with applicable produced under a quality-control program with sections of the ICC-ES Acceptance Criteria for Foam inspections by ICC-ES. Plastic Sheathing Used as a Water-resistive Barrier (AC71), dated February 2013 (editorially revised 6.0 EVIDENCE SUBMITTED January 2016). 6.1 Data in accordance with the ICC-ES Acceptance 7.0 IDENTIFICATION Criteria for Spray-applied Foam Plastic Insulation, Containers of Icynene ProSeal and Icynene ProSeal LE (AC377), dated April 2016, including reports of tests components are identified with a label bearing the Icynene, in accordance with Appendix X of AC377. Inc., name and address; the product trade name [Icynene 6.2 Report of air permeance test in accordance with ProSeal]; the lot number; the flame spread and smoke ASTM E2178. developed indices; mixing instructions; density; the shelf 6.3 Report of vapor permeance test in accordance with life and the expiration date; and the evaluation report ASTM E96. number(ESR-3500). 6.4 Engineering analysis of a fire-resistance test in The International Fireproof Technology / Paint To accordance with ASTM E119. Protect, Inc DC-315 intumescent coating is identified with the manufacturer's name, the product trade name, use 6.5 Engineering analysis of a fire test in accordance with instructions and ICC-ES evaluation report number NFPA 285. ESR-3702. 6.6 Report of a room corner fire test in accordance with NFPA 286. I TABLE 1-THERMAL RESISTANCE(R-VALUES) THICKNESS(inches) R-VALUE(°F.ft'.htBtu) 1.0 71 3.5 24 4.0 28 5.5 38 6.0 42 7.5 52 8.5 59 9.5 66 10.0 69 11.25 78 For SI:1 inch=25.4 mm;VF ft'.hlBtu=0.176110°K.m'h/W. 'R-values are calculated based on tested K-values at 1-and 3 54nch thicknesses i 1 TABLE 2-NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES ESR-3500 I Most Widely Accepted and Trusted Page 5 of 5 Wall Component Materials Base Wall System— 1—Concrete wall Use either 1,2 or 3 2—Concrete masonry wall 3—Minimum 35/8-inch-deep(92 mm),No.20 gage,C-shaped steel studs,spaced a maximum of 24 inches on center with lateral bracing every 4 feet(1219 mm)as required by code Sheathing shall be a described in Exterior Sheathing below Floorlme Firestoppmg Minimum 4 pcf mineral wool in each stud cavity at each floorlme,attached with Z-clips.Thickness must match stud cavity depth Cavity Insulation—Use either 1,2 3,4 1—None. or 5 2—Partial cavity fill with a maximum air space of 2 inches(51 mm)or full cavity depth not exceeding 75/8 Inches(194 mm)of Classic,Classic Plus or Classic Max(ESR-1826);MD-R-210(ESR-3493);or Proseal/ProSeal LE(ESR-3500) 3—Any insulation qualified as noncombustible in accordance with ASTM Ell 36. 4—Glass fiber batt insulation'. 5—Mineral fiber insulation'. Insulation must comply with the applicable requirements of 2015 or 2012 IBC Section 720.2(2009 IBC Section 719.2). Exterior Sheathing—Only for Base Wall 1—Minimum'/2-inch-thick(12.7 mm),),glass mat gypsum sheathing complying with ASTM C1177. System No 3— 2—Sheathing shall be attached with No 6,11/4-inch-long(32 mm)self-tapping screws located 8 Use either 1 or 2 inches(203 mm)on center along the perimeter and 12 inches 302 mm)on center in the field of wallboard.Joints must be taped and treated with joint compound in accordance with ASTM C840 or GA-216 Exterior Insulation Maximum thickness of 02 inches(140 mm)of Proseal Eco(MD-R-210)(ESR-3493)or ProseallProSeal LE(ESR-3500) Exterior Wall Covering— 1—Brick-standard nominally 4-inch-thick(102 mm)clay brick;brick veneer anchors—standard Use either 1,2,3,4,5,6 or 7 types installed a maximum of 24 inches OC vertically on each stud 2—Stucco-minimum 314-inch-thick(19.1 mm),exterior cement plaster and lath with a secondary water-resistive barrier may be installed between the exterior insulation and the lath. 3—Natural stone(limestone,granite,marble,sandstone),minimum 2-inch-thick(51 mm)°. 4—Cast artificial stone,minimum 1'/2-inch-thick(38 mm),complying with AC51 and subject of a current ICC-ES evaluation report° 5—Terracotta cladding,minimum of 1'/4—mch-thick(32 mm)`. 6—Precast concrete panels,minimum of 1112—inch-thick(32 mm)`. 7—Concrete masonry untis(CMU),minimum of 1'/2—inch-thick(38 mm)° b The maximum air gap between exterior insulation and cladding shall be 2 inches(51 mm) Any standard non-open-jointed installation technique such as ship-lap,etc.,may be used vKj-oys.,.e 1..vm. w¢+ DC315 Intumescent Coating Your one step solution for Polyurethane Foam"15 Minute Thermal Barrier"and "Ignition Barrier"ratings. DC315 is a Certified Warnock Hersey listed and rated product which has passed certified testing for both the(UL- 1715) 15 minute Thermal Barrier and the NFPA 286(AC-377 standards)as an Ignition Barrier. DC315 applies as easily as regular latex paint and being a water base cleans up in a snap. Using DC315 will satisfy code compliance on"15 Minute Thermal Barriers"and"Ignition Barriers"on your next foam job means: • Large single coat spread rate • UL 1715 Thermal Barrier ■ (88.88 sq.ft./gal @ 18 mils wet and 12 mils dry)coverage rate of 1.136 gallons(4.3 Q per 100 square feet(9.3 mZ) • NFPA 286 (AC377)Attic Crawl Space Ignition Barrier ■ (130 sq.ft./gal @ 12 mils wet 8 mils dry)coverage rate of.77 gallons(2.9 L)per 100 square feet(9.3 mZ) • Reduced labor cost,reduced material cost and higher profits • Fast turnaround time • Easily applied with a sprayer,brush or roller • No complicated mixing-just stir the paint before application • No waste • Fast and easy clean up of our water based latex product,tools&equipment • Will not gum up or block spray equipment • Passed strict EPA—VOC and AMQD tests • No formaldehyde QliS • Non Toxic,Low Vapors,Low VOCs less than 50 making DC-315 a Green Product • Earn 2 LEED points for using DC-315 • Two year shelf life • Certified Code Compliant Coating RECOMMENDED USES:This product is designed for use on interior polyurethane foam surfaces. USED BY:Schools,Colleges, Nursing Homes,Child Care Centers, Hospitals,Penal Institutions,Apartments,Hotels, Factories,Warehouses,Retail Stores, Restaurants, Utilities, Railroad and other Transportation Companies,Oil and Chemical Installations;Military Installations,and other facilities where fire retardant coatings are required. PRECAUTIONS: Adequate ventilation must be provided during and after application until the coating has dried.Avoid breathing vapors or spray mist.Close container after use. Read MSDS before opening containers. 3 `:ria•b:i 01W i , ;'1 tf+h a +s}-I�i + )I`1 �i N�s+adPMls}Ci. SURFACE PREPARATION:Can be applied directly to fully cured polyurethane foam surfaces.All surface preparation should be carried out in accordance with good painting practices. Remove all loose,peeling.or powdery existing paint from the surface.All dirt,grease,oil,wax,and other foreign matter MUST be removed with a detergent,rinse surface thoroughly with clear water,and allow drying. APPLICATION EQUIPMENT: DC315 can be applied by brush,roller or airless sprayer Brushing: Use top quality polyester/nylon blend brushes such as those supplied by Purdy,Wooster,or equivalent Rolling: 3/8"polyester blend nap roller covers generally work well Spraying:Pump:(Graco)for best results use Graco 795 airless sprayer,with a minimum 2000 PSI • Tip:526—529 or equivalent • Filter:60 mesh • Hose:Use minimum size of 3/8"airless spray line for the first 50'from pump Airless Spray: • Fluid Pressure: ........................2000 PSI or higher • Strainer:..................................60 Mesh • Fluid Hose:..............................3/8 diameter with a 1/4"whip • Tip:..........................................021-.029 Conventional Spray • Air Supply....................................12 CFM,50 psi at nozzle, • Fluid..............................................15-20 psi • Gun..........................................Graco 217-800 to 217-816 • Type.............................................External Mix • Reduction....................................Up to 7% APPLICATION:Stir thoroughly and apply WFT per test. Do not apply in temperatures below 507(10"C). CHARACTERISTICS: ASTM E 84 Testing Flame Spread of 5, Smoke Development of 300 Finish Flat Color Off-White Spreading Rate For 15 minute Thermal Barrier(88.88 sq.ft./gal @ 18 mil wet and 12 mils Dry) coverage rate of 1.136 gallons(4.3 L)per 100 square feet(9.3 M2) Spreading Rate For AC377 Attic Crawl Space(130 sq.ft./gal @ 12 mil wet 8 mils Dry)coverage rate of 77 gallons(2.9 L)per 100 square feet(9:3 m2) V.O.C. (47 g/1) Volume Solids 65% Drying Time @ 77°F&50%RH To touch in 1-2 hours,to recoat 2-4 hours E Type of Cure Coalescence KED ARC�5� Flash Point None Reducer/Cleaner Water Shelf Life 2 years(unopened) s t°' 1ar Packaging 5 gallon pails Shipping Weight 5 gallon pail—58 lbs N� c Application Brush,roller,conventional and airless spray '9T o3oB1A Q� SOF NE`N�l ICC EVALUATIONMost�Widely Accepted and Trusted ReportSERVICE I,cavwx'w om Innovation, RESFARCH LABS 11 , . , 1/2017 This report is subject to renewal 01/2018. DIVISION:07 00 00—THERMAL AND MOISTURE PROTECTION SECTION:07 2100—THERMAL INSULATION REPORT HOLDER: ;'X' ICYNENE, ICYNENE, INC. `��' 6747 CAMPOBELLO ROAD MISSISSAUGA, ONTARIO L5N 2L7 CANADA - 9X� 3081 �OQ� OF NES EVALUATION SUBJECT: ICYNENE PROSEAL AND ICYNENE PROSEAL LE t ICC ICC ICC iXR"I y c t PING LISTED ' Look for the trusted marks of Conformity! �® ice! "2014 Recipient,of Prestigious Western States Seismic Policy,Council ■®® (WSSPC)Award in Excellence" J A Subsidiary of co�ECOUNca ICC-ES Evaluation Reports are not,to be construed as representing aesthetics or any other attributes not eked specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as Gqg NW ans,�mmawereor+m to any finding or other matter in this report, or as to any product covered by the report. � � , + cce Copyright 0 2017 ICC Evaluation Service,LLC. All rights reserved. ICC EVALUATION Accepted . . IMES Evaluation Report ESR-3500 Reissued January 2097 This report is subject to renewal January 2098. wwwAcc-es.orcl 1 (800)423-6587 1 (562)699-0543 A Subsidiary of the lntemational Code Council® DIVISION:07 00 00—THERMAL AND MOISTURE 2.0 USES PROTECTION Icynene ProSeal and Icynene ProSeal LE spray foam is Section:07 21 00—Thermal Insulation used as a nonstructural thermal insulating material in REPORT HOLDER: Types I, II, III, IV and V construction under the IBC and dwellings under the IRC. The insulation is for use in wall ICYNENE,INC. cavities,floor assemblies,ceiling assemblies, or attics and 6747 CAMPOBELLO ROAD crawl spaces when installed in accordance with Section MISSISSAUGA,ONTARIO L5N 2L7 4.4. Under the IRC, the insulation may be used as air- , CANADA impermeable insulation when installed in accordance with (905)363-4040 Section 3.4, and as a vapor retarder when installed in www.icVnene.com accordance with Section 3 5 Icynene ProSeal spray foam ievansAicvnene.com may be used in fire-resistance-rated construction when installed in accordance with Section 4.5, and in Types I EVALUATION SUBJECT: through IV construction when installed in accordance with Section 4.6. The insulation may be used as an alternative ICYNENE PROSEAL AND ICYNENE PROSEAL LE to the water-resistive barrier required in IBC Section 1404.2 and IRC Section R703.2 when installed as 1.0 EVALUATION SCOPE described in Section 4 7. 1.1 Compliance with the following codes: 3.0 DESCRIPTION ■ 2015,2012 and 2009 International Building Code®(IBC) 3.1 ProSeal Insulation: ■ 2015, 2012 and 2009 International Residential Code® Icynene ProSeal and Icynene ProSeal LE foam plastic (IRC) insulation is a two-component, medium-density, closed- cell, spray-applied foam plastic with a nominal density of ■ 2015, 2012 and 2009 International Energy Conservation 2.4 pcf. The polyurethane foam is produced by combining Code®(IECC) Icynene Based Seal MDI isocyanate (the A component) Properties evaluated: and Icynene ProSeal resin (the B component). The products have a shelf life of 12 months when stored in ■ Surface-burning characteristics factory-sealed containers at temperatures between 60°F ■ Physical properties and 85°F (16°C and 29°C). The Icynene ProSeal is ■ Thermal resistance(R-values) supplied in one formula for all climates. , The attributes of the insulation have been verified as ■ Attic and crawl-space installation conforming to the requirements of ICC 700-2008 Section ■ Air permeability 703.2.1.1.1(c) as an air impermeable insulation. Note that decisions on compliance for those areas rest with the user ■ Vapor permeability of this report. The user is advised of the project-specific ■ Fire–resistance-rated construction provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is ■ Water-resistive barrier outside the scope of this report These codes or standards ■ Exterior walls of Types I–IV construction often provide supplemental information as guidance. 1.2 Evaluation to the following green standard: 3.2 Surface Burning Characteristics: ■ 2008 ICC 700 National Green Building StandardTM The Icynene ProSeal and Icynene ProSeal LE insulation, ([CC 700-2008) at a maximum thickness of 4 inches (102 mm) and a Attributes verified: nominal density of 2.4 pcf, has a flame-spread index of 25 or less and a smoke-developed index of 450 or less when ■ See Section 3.1 tested in accordance with ASTM E84(UL 723). ICC-ES Evaluation Repot is m e not to be conn ned as rep esenting aesthetics or anY other attributes not epectfically adds essed nor at e the,to be construed as an endorsement of the subject of the report or a i ecommendanon for its use.Thei a is no n m ranty by 1CC Evaluation Service,LLC,express m implied,as to anv finding or other matter in this report,or as to any product covered by the report wins rl°m� Copyright©2017 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 5 D G 0 [ DD ERGY SPRAY SYSTEMS, LLC MAY - 6 2019 9 CUMMINGS AVE,STAMFORD CT 06902 ^ TEL-(203)536-3388,FAX-(203)321-3096 TOWN OF souriio - INSULATION CER TIFICAT The following spray polyurethane foam product(s)has/have been installed. Consult International Building Code,chapter 26-Plastic and International Residential Code(IRC)R314 Foam Plastics for specific requirements.The spray polyurethane foam insulation system(s)has/have been installed in accordance with manufactdrer's processing guidelines to provide a thermal resistance of: Main House Roof Rafters 2x4 R-24 Closed-Cell Attic Gables R-24 Closed-Cell Framed Exterior Walls 2x4 R-24 Closed-Cell Floor Joists Above Existing Basement+Crawl Space R-21 Closed-Cell Paint—In Basement Ceiling DC315 15-Min Thermal Barrier Paint—In Crawl Space Ceiling DC315 15-Min Thermal Barrier Pack Around All'Doors&Windows Can Foam Foam Hilti Jobsite'Address: 15 Sun Lane.,Southold,NY Date of insulation: April 2019 Insulation Contractor: Energy Spray Systems, LLC Installed By:Florjan Shehaj 5 PNoo � N V1 ! Authorizing Certificate: Aldo Custodio D X3080ENERGY SPRAY SVSTEQ�S LIC -Post Near Electrical Panel- T$OF NE`N 9 CUMli INGS AVE STAMF0I4D CT 06902 ENERGY SPRAY SYSTEMS, LLC 9 CUMMINGS AVE,'STAMFORD CT 06902 TEL-(203)536-3388, FAX-(203)321-3096 Date: Apiffl20119 *Job Name 15 Sun Lane. Southold,NY *Details Our company Paint with DC-315 The'rmal Barrier the foam left exposed in Basement Ceiling and Crawl Space Ceiling. Spreading rate-For Thermal Barrier AC 377 Appendix X I4, .:;. °,`.ra€ Li dry mils with a Tip Size of.517 Energy Spray Systems',LLC EMERGV SPRAY SYSTE�MS LLC 9 CUMMINGS AVE STAMFORD CT 06902 ��REo ARch,�T %IPS �•9 0308Ap' TFOF NES c tvirm cE II+ DC 315- . r_—Z I MAIN FlooR- S1rori,-' l 4WeC cam►LiNfo1kv°F= K-2'4 WALLS f-7A 69AWL 5?AW-Z�'�C1A-L $A`. /1 v ra :: F _ • S r . r NNW& "'o"I 81c %APV Ra.�l to J7 y' y-T,� — J�j 1 j ` N1,41 1j rcvMLI L-lv/Nb "OM I-t'V/N6 "0&1 bAf McW7- SOv70 OLD NV t "' �oP,NDp,,, ` tB 1 . J 08J4 .�C) OF NEIN Gt"0O 6 C'A lkolbl 5?"Y SAM r SVI++'noN } UKIVCV WOOD :FIDW, P . LI rra Are- L 220)—I - ESC Most Widely Accepted and Trusted EVALUATION RVICE ICC-ES Report , ESR-3500 ICC-ES (800)423-61587 1 (562) . . , , 01/2017 This report is subject to renewal 01/ZO18. DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 2100=THERMAL INSULATION, J REPORT HOLDER: ANDp ICYNENE, INC. No. 6747 CAMPOBELLO ROAD MISSISSAUGA, ONTARIO L5N 2L7" CANADA 9�� 030814 �F NE�� EVALUATION SUBJECT: ICYNENE PROSEAL AND ICYNENE PROSEAL LE r ICC . ICC ICC C PMG LISTED Look for the trusted marks of Conformity! i\- "2014 Recipient of Prestigious Western States Seismic Policy Council man NIERWSSPC Award in Excellence" 'CODE OUNCIL � � A Subsidiary of CODEC011NCIL° ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not sccC W specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a 1 recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as GO , AM to any finding or other matter in this report, or as to any product covered by the report. �CAnoa Copyright°2017 ICC Evaluation Service, LLC. All rights reserved. ESEVALUATIONSERVICE Most WidelyAccepted and Trusted ICC-ES Evaluation Report ESR-3500 Reissued January 2017 This report is subject to renewal January 2018. www.icc-es.org 1 (800)423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° DIVISION:07 00 00—THERMAL AND MOISTURE 2.0 USES PROTECTION Icynene ProSeal and Icynene ProSeal LE spray foam is Section:07 21 00—Thermal Insulation used as a nonstructural thermal insulating material in REPORT HOLDER: Types I, II, III, IV and V construction under the IBC and dwellings under the IRC. The insulation is for use in wall ICYNENE, INC. cavities,floor assemblies, ceiling assemblies, or attics and 6747 CAMPOBELLO ROAD crawl spaces when installed in accordance with Section MISSISSAUGA,ONTARIO L5N 21_7 4.4. Under the IRC, the insulation may be used as air- CANADA I impermeable insulation when installed in accordance with (905)363-4040 Section 3.4, and as a vapor retarder when installed in www.icynene.com accordance with Section 3.5. Icynene ProSeal spray foam ievans(a)icvnene.com may be used in fire-resistance-rated construction when installed in accordance with Section 4.5, and in Types I EVALUATION SUBJECT: through IV construction when installed in accordance with Section 4.6. The insulation may be used as an alternative ICYNENE PROSEAL AND ICYNENE PROSEAL LE to the water-resistive barrier required in 'IBC Section 1404.2 and IRC Section R703.2 when installed as 1.0 EVALUATION SCOPE described in Section 4 7. 1.1 Compliance with the following codes: 3.0 DESCRIPTION ■ 2015,2012 and 2009 International Building Codee(IBC) 3.1 ProSeal Insulation: ■ 2015, 2012 and 2009 International Residential Code® Icynene ProSeal and Icynene ProSeal LE foam plastic (IRC) insulation is a two-component, medium-density, closed- cell, spray-applied foam plastic with a nominal density of ■ 2015, 2012 and 2009 International Energy Conservation 2.4 pcf. The polyurethane foam is produced by combining Code®(IECC) Icynene Based Seal MDI isocyanate (the A component) Properties evaluated:- and Icynene ProSeal resin (the B component)'. The products have a shelf life of 12 months when stored in ■ Surface-burning characteristics factory-sealed containers at temperatures between 60°F ■ Physical properties and 85°F (16°C and 29°C). The Icynene ProSeal is ■ Thermal resistance(R-values) supplied in one formula for all climates. The attributes of the insulation have been verified as ■ Attic and crawl-space installation conforming to the requirements of ICC 700-2008 Section ■ Air permeability 703.2.1.1.1(c) as an air impermeable insulation. Note that decisions on compliance for those areas rest with the user ■ Vapor permeability of this report. The user is advised of the project-specific ■ Fire-resistance-rated construction provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is ■ Water-resistive barrier outside the scope of this report.These codes or standards ■ Exterior walls of Types I-IV construction often provide supplemental information as guidance. 1.2 Evaluation to the following green standard: 3.2 Surface Burning Characteristics: ■ 2008 ICC 700 National Green Building Standard TM The Icynene ProSeal and Icynene ProSeal LE insulation, (ICC 700-2008) at a maximum thickness of 4 inches (102 mm) and a Attributes verified: nominal density of 2.4 pcf, has a flame-spread index of 25 or less and a smoke-developed index of 450 or less when ■ See Section 3.1 tested in accordance with ASTM E84(UL 723). ICC-ES Evaluation Reports are not to be const ued as i epi esenting aesthetics or any other attributes not specifically addressed,not m e they to be construed FF as an endorsement of the subject of the repo?t of a recommendation for its use.There is no warre n y by ICC Evaluation Service,LLC,expi ess or unphed,as C to any finding or othei mattes in this report,of as to any product covered by the report. ^ ,mom•••' Copyright©2017 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 5 ESR-3500 I Most Widely Accepted and Trusted Page 2 of 5 3.3 Thermal Resistance: insulation and the interior of the building. There is no Icynene ProSeal and Icynene ProSeal LE insulation has a thickness limit when installation is behind a code- thermal resistance, R-value, at a mean temperature of prescribed thermal barrier except as noted in Sections 75°F(24°C)as shown in Table 1. 4.4.2.1,4.4.2 2 and 4.4.3. 3.4 Air Permeability: 4.3.2 Application without a Prescriptive Thermal Barrier with DC 315 Intumescent Coating: Icynene Icynene ProSeal and Icynene ProSeal LE insulation, at a ProSeal and Icynene ProSeal LE may be installed without minimum 1.4-inch (35.6 mm) thickness, is considered air- the 15-minute thermal barrier prescribed in IBC Section impermeable insulation in accordance with 2015 IBC 2603.4 and IRC Section R316.4,when the installation is in Section 1203.3 and 2015 and 2012 IRC Section R806.5 accordance with this section. The Icynene ProSeal (2009 IRC Section R806.4), based on testing in insulation and the DC 315 intumescent coating may be accordance with ASTM E2178. spray-applied to the interior facing of walls, the underside 3.5 Vapor Permeability: of roof sheathing or roof rafters, and in crawl spaces, and may be left exposed as an interior finish without a Icynene ProSeal and Icynene ProSeal LE insulation has a 15-minute thermal barrier or ignition barrier. The thickness vapor P,ermeance of less than 1 perm (5.7x10" kg/ of the insulation applied to the underside of the roof Pa-s-m at a minimum thickness of 1.5 inches (38.1 mm) sheathing must not exceed 14 inches (356 mm). The and may be used where a Class II vapor retarder is thickness of the insulation applied to vertical wall surfaces required by the applicable code. must not exceed 8 inches (203 mm). The insulation must 3.6 Intumescent Coatings: be covered on all surfaces with DC 315 intumescent coating at a minimum wet film thickness of 24 mils wet 3.6.1 DC 315: DC 315 intumescent coating (ESR-3702), (0.61 mm) [16 mils dry(0.41 mm)] at an application rate of manufactured by International Fireproof Technology, Inc., 1 gallon (3.8 L)per 66.8 square feet(6.15 MI).The coating is a water-based coating supplied in 5-gallon (19 L) pails must be applied over the Icynene ProSeal insulation in and 55 gallon (208 L) drums. The coating material has a accordance with the coating manufacturer's instructions, shelf life of 12 months when stored in factory-sealed ESR-3702 and this report. Surfaces to be coated must be containers at temperatures between 50°F (10°C) and dry, clean, and free of dirt, loose debris and other 80°F(24°C). substances that could interfere with adhesion of the 4.0 DESIGN AND INSTALLATION coating. The coating is applied in one coat with low- 4.1 General: pressure airless spray equipment. Icynene ProSeal and Icynene ProSeal LE must be installed 4.4 Attics and Crawl Spaces: in accordance with the manufacturer's published 4.4.1 Application with a Prescriptive Ignition Barrier: installation instructions,this report and the applicable code. When Icynene ProSeal and Icynene ProSeal LE insulation The manufacturer's published installation instructions and is installed within attics or crawl spaces where entry is this report must be strictly adhered to, and a copy of the made only for service of utilities, an ignition barrier must be instructions and this evaluation report must be available on installed in accordance with IBC Section 2603 4 1.6 or IRC the jobsite at all times during installation. Sections R316.5.3 and R316.5.4, as applicable. The 4.2 Application: ignition barrier must be consistent with the requirements for the type of construction required by the applicable Icynene ProSeal and Icynene ProSeal LE must be applied code, and must be installed in a manner so that the foam using spray equipment specified by Icynene, Inc. The plastic insulation is not exposed. Icynene ProSeal and insulation must not be used in areas having a maximum Icynene ProSeal LE insulation may be installed in service temperature greater than 180°F (82°C), must not unvented attics in accordance with 2015 IBC Section be used in electrical outlet or junction boxes or in contact 1203.3 or 2012 IRC Section R806.5 (2009 IRC Section with rain or water, and must be protected from the weather R806.4). during and after application. Where Icynene ProSeal and Icynene ProSeal LE is used as an air-impermeable barrier, 4.4.2 Application without a Prescriptive Ignition such as in unventilated'attic spaces regulated by IRC Barrier: Where Icynene ProSeal spray foam is installed in Section R806, the insulation must be installed at a an attic or crawl space without a prescriptive ignition minimum thickness of 1.4 inches(35 6 mm).The insulation barrier, in accordance with Sections 4.4.2.1 and 4.4.2.2, is applied;to the intended thickness, with the first pass the following conditions apply: being at the maximum thickness set forth in the 1. Entry to the attic or crawl space is only for the service manufacturer's published installation instructions. Where of utilities and no storage is permitted. multiple passes are required, the cure time between each pass is in accordance with the manufacturer's instructions. 2. There are no interconnected attic, crawl space or 4.3 Thermal Barrier: basement areas 4.3.1 Application with a Prescriptive Thermal Barrier: 3. Air in the attic or crawl space is not circulated to other Icynene ProSeal and Icynene ProSeal LE spray foam parts of the building. insulation must be separated from the interior of the 4. Combustion air is provided in accordance with IMC building by an approved thermal barrier, such as /2-inch- (International Mechanical Code®)Section 701. thick (12.7 mm) gypsum board installed using mechanical fasteners in accordance with the applicable code, or an 5. Attic ventilation is provided when required by IBC equivalent 15-minute thermal barrier complying with, and Section 1203.2 or IRC Section R806, except when air- installed in accordance with, IBC Section 2603.4 or IRC impermeable insulation is permitted in unvented attics Section R316.4, as applicable. When installation is within in accordance with 2015 IBC Section 1203.3 or 2012 an attic or crawl space as described in Section 4.4, IRC Section R806.5(2009 IRC Section R806.4). a thermal barrier is not required between the foam plastic 6. Under-floor (crawl space) ventilation is provided when and the attic or crawl space, but is required between the ESR-3500 I Most Widely Accepted and Trusted Page 3 of 5 required by 2015 IBC Section 1203.4 (2012 and 2009 self-drilling drywall screws spaced 8 inches (203 mm) on IBC Section 1203.3) or IRC Section R408.1, as center around the perimeter and 12 inches (305 mm) on applicable. center in the field. The gypsum board joints must be 4.4.2.1 Attics and Crawl Spaces - Uncoated: The treated with vinyl or casein, dry or premixed joint thickness of the foam plastic applied to the underside of compound applied in two coats to cover all exposed screw the roof sheathing and/or rafters,or the underside of floors, heads and gypsum board butt joints. A minimum 2-inch- must not exceed 8 inches (203 mm). The thickness of the wide (51 mm) paper, plastic, or fiberglass tape is spray foam insulation applied to vertical wall surfaces must embedded in the first layer of compound over butt joints of not exceed 6 inches (152 mm). The insulation does not the gypsum board. require a code-prescribed ignition barrier or coating. 4.6 Exterior Walls in Type 1,II,III and IV Construction: 4.4.2.2 Attic and Crawl Spaces-Coated:The thickness 4.6.1 General:When used on exterior walls of Types I, II, of the foam plastic applied to the underside of the roof III or IV construction, the assembly must comply with IBC sheathing and/or rafters, or the underside of floors, must Section 2603.5 and this section, and the Icynene ProSeal not exceed 14 inches (356 mm). The thickness of the and Icynene ProSeal LE insulation must be installed at a spray foam insulation'applied to vertical wall surfaces must maximum thickness as described in Table 2. The potential not exceed 8 inches(203 mm). heat of Icynene ProSeal insulation is 2288 Btu/ft2 (25995 kJ/ml) per inch "of thickness, when tested in The Icynene ProSeal and Icynene ProSeal LE insulation accordance with NFPA 259. must be covered on all surfaces with 4.6.2 Specific Wall Assemblies: Wall assemblies DC315 ata minimum dry film thickness of 3 mils complying with Section 4.6 must be as described in Table (0.08 mm)[wet film thickness of 4 mils(0.10 mm)]at a rate 2 of 401 square feet(37 m2)per gallon(3.8 L). 4.7 Water-resistive Barrier: The coating must be applied over the Icynene ProSeal and Icynene ProSeal LE insulation in accordance with the Icynene ProSeal and Icynene ProSeal LE insulation may coating manufacturer's instructions and this report. be used as an alternative to the water-resistive barrier Surfaces to be coated must be dry, clean, and free of dirt, prescribed in IBC Section 1404.2 and IRC Section R703.2, loose debris and other substances that could interfere with when installed on exterior walls as described in this section adhesion of the coating.The coating is applied in one coat the insulation must be spray-applied to the exterior side of with low-pressure airless spray equipment. sheathing, masonry or other suitable exterior wall substrates to form a continuous layer of 1 inch (25.4 mm) 4.4.3 Use on Attic Floors: Icynene ProSeal and Icynene minimum thickness All construction joints and penetrations ProSeal LE insulation may be installed exposed at a are to be completely sealed with Icynene ProSeal or maximum thickness of 14 inches (356 mm) between and Icynene ProSeal LE insulation. over the joists in attic floors The insulation must be separated from the interior of the building by an approved 5.0 CONDITIONS OF USE thermal barrier. An ignition barrier in accordance with the The' Icynene ProSeal and ProSeal LE spray foam IBC Section 2603.4 and IRC Section R316.5.3 may be insulation described in this report complies with, or is a omitted. suitable alternative to what is specified in, those codes 4.5 One-hour Non-load-bearing Fire-resistance-rated listed in Section 1.0 of this report, subject to the following Wall Assembly: conditions: 4.5.1 Exterior Face: Nominally 6-inch-deep (152 mm), 5.1 The product must be installed in accordance with No. 18 gage galvanized steel studs, spaced 16 inches the manufacturer's published installation instructions, (406 mm) on center, are fastened to No. 18 gage this evaluation report and the applicable code. In the galvanized steel floor and ceiling tracks. One lager of event of a conflict between the manufacturer's /2-inch-thick (12.7 mm) Georgia Pacific DensGlass Gold published installation instructions and this report, this Exterior Sheathing is installed parallel to the steel studs report governs. with vertical joints offset a minimum of 16 inches(406 mm) 5.2 The insulation must be separated from the interior of from the vertical joints of the interior Type X gypsum board, the building by an approved 15-minute thermal barrier and the horizontal joints offset a minimum of 24 inches in accordance with IBC Section 2603.4, except when (610 mm) from the horizontal joints of the gypsum board. installation is as described in Section 4.3.2 or in attics The sheathing is attached using 11/4-inch long (31.7 mm), and crawl spaces as described in Section 4.4.2. self-drilling drywall screws spaced 8 inches (203 mm) 5.3 The insulation must not exceed the thickness and on center around the perimeter and in the field. Hohmann density noted in Sections 3.2,4.3,4.4, 4.5 and 4.6 of & Barnard DW-10' brick ties, 6 inches (152 mm) long this report. by 1 /2 inches (38 mm) wide, are spaced 16 inches (406.4 mm) on center vertically on each steel stud, and 5.4 The insulation must be protected from the weather secured using two 15/a-inch-long (41.3)self-drilling screws, during and after application. through 4-inch (102 mm) red clay brick [33/2 inches 5.5 The insulation must be applied by installers certified (89 mm) by 21/4 inches (57 mm) by 73/4 inches (197 mm)], laid in a running bond pattern with Type S by Icynene, Inc. mortar, leaving a nominally 1-inch (25.4 mm) air gap 5.6 Use of the insulation in areas where the probability of between the brick and the exterior sheathing. The stud termite infestation is "very heavy' must be in cavity is filled with Icynene ProSeal insulation and Icynene accordance with IRC Section R318.4 or 2012 IBC ProSeal LE to a maximum nominal thickness of 6 inches. Section 2603.9 (2009 IBC Section 2603.8), as 4.5.2 Interior Face: Type X gypsum board, 5/9 inch applicable. (15.9 mm) thick and complying with ASTM C1396, is 5.7 Jobsite certification and labeling of the insulation must applied to the interior side with the long edge parallel to comply with 2015 IRC Sections N1101.10.1 and steel studs, and is secured using 11/4-inch-long (32 mm), N1101.10.1.1 (2012 IRC Sections N1101.12.1 and ESR-3500 I Most Widely Accepted and Trusted Page 4 of 5 N1101.12.1.1 or 2009 IRC Sections N1101.4 and 6.7 Report of a potential heat test in accordance with N1101.4.1) and 2015 and 2012 IECC Sections NFPA 259. C303.1.1, C303.1.1.1, R303.1.1 and R303.1.1.1 6.8 Report of a critical radiant flux test in accordance with (2009 IECC Sections 303.1.1 and 303.1.1.1), as ASTM E970. applicable. 5.8 The A and B components of the insulation are 6.9 Reports of tests in accordance with applicable produced under a quality-control program with sections of the ICC-ES Acceptance Criteria for Foam inspections by ICC-ES. Plastic Sheathing Used as a Water-resistive Barrier (AC71), dated February 2013 (editorially revised 6.0 EVIDENCE SUBMITTED January 2016). 6.1 Data in accordance with the ICC-ES Acceptance 7.0 IDENTIFICATION Criteria for Spray-applied Foam Plastic Insulation, Containers of Icynene ProSeal and Icynene ProSeal LE (AC377), dated April 2016, including reports of tests components are identified with a label bearing the Icynene, in accordance with Appendix X of AC377. Inc., name and address; the product trade name [Icynene 6.2 Report of air permeance test in accordance with ProSeal]; the lot number; the flame spread and smoke ASTM E2178 developed indices; mixing instructions; density; the shelf 6.3 Report of vapor permeance test in accordance with life and the expiration date; and the evaluation report ASTM E96. number(ESR-3500). 6.4 Engineering analysis of a fire-resistance test in The International Fireproof Technology / Paint To accordance with ASTM E119. Protect, Inc. DC-315 intumescent coating is identified with the manufacturer's name, the product trade name, use 6.5 Engineering analysis of a fire test in accordance with instructions and ICC-ES evaluation report number NFPA 285. ESR-3702. 6.6 Report of a room corner fire test in accordance with NFPA 286. TABLE 1-THERMAL RESISTANCE(R-VALUES) THICKNESS(inches) R-VALUE(°F.ftl.h/Btu) 1.0 7.1 3.5 24 4.0 28 55 38 6.0 42 7.5 52 8.5 59 9.5 66 10.0 69 11.25 78 For SI:1 inch=25 4 mm,1°F.ft2 h/Btu=0 176110°K m2 h/W. 'R-values are calculated based on tested K-values at 1-and 3 5-inch thicknesses. TABLE 2-NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES ESR-3500 I Most Widely Accepted and Trusted Page 5 of 5 Wall Component Materials Base Wall System— 1—Concrete wall Use either 1,2 or 3 2—Concrete masonry,wall. 3—Minimum 35/8-inch-deep(92 mm),No 20 gage,C-shaped steel studs,spaced a maximum of 24 inches on center with lateral bracing every 4 feet(1219 mm)as required by code.Sheathing shall be a described in Exterior Sheathing below. Floorline Firestopping Minimum 4 pcf mineral wool in each stud cavity at each floorline,attached with Z-clips.Thickness must match stud cavity depth. Cavity Insulation—Use either 1,2 3,4 1—None. or 5 2—Partial cavity fill with a maximum air space of 2 inches(51'mm)or full cavity depth not exceeding 75/8 inches(194 mm)of Classic,Classic Plus or Classic Max(ESR-1826),MD-R-210(ESR-3493);or Proseal/ProSeal LE(ESR-3500). 3—Any insulation qualified as noncombustible in accordance with ASTM El 36. 4—Glass fiber batt msulationa 5—Mineral fiber insulation Insulation must comply with the applicable requirements of 2015 or 2012 IBC Section 720 2(2009 IBC Section 719.2) Exterior Sheathing—Only for Base Wall 1—Mmimum'/2-inch-thick(12 7 mm),),glass mat gypsum sheathing complying with ASTM C1177 System No.3— 2—Sheathing shall be attached with No 6, 11/4-inch-long(32 mm)self-tapping screws located 8 Use either 1 or 2 inches(203 mm)on center along the perimeter and 12 inches 302 mm)on center in the field of- wallboard.Joints must be taped and treated with joint compound in accordance with ASTM C840 or GA-216. Exterior Insulation Maximum thickness of 5'/2 inches(140 mm)of Proseal Eco(MD-R-210)(ESR-3493)or Proseal/ProSeal LE(ESR-3500) Exterior Wall Covering— 1—Brick-standard nominally 4-inch-thick(102 mm)clay brick;brick veneer anchors—standard Use either 1,2,3,4,5,6 or 7 types installed a maximum of 24 inches OC vertically on each stud°. 2—Stucco-minimum 3/44nch4hick(19.1 mm),exterior cement plaster and lath with a secondary water-resistive barrier may be installed between the exterior insulation and the lath. 3—Natural stone(limestone,granite,marble,sandstone),minimum 2-inch-thick(51 mm)° 4—Cast artificial stone,minimum 1'/2-inch-thick(38 mm),complying with AC51 and subject of a current ICC-ES evaluation report' 5—Terracotta cladding,minimum of 11/4—inch-thick(32 mm)' 6—Precast concrete panels,minimum of 11/zinch-thick(32 rrim)°. 7—Concrete masonry untis(CMU),minimum of 1'/2—inch-thick(38 mm)°. b The maximum air gap between exterior insulation and cladding shall be 2 inches(51 mm) °Any standard non-open-jointed installation technique such as ship-lap,etc,may be used. r � ftaAmarhmlwfea fit � DC315 Intumescent,Coating Your one step solution for Polyurethane Foam"15 Minute Thermal Barrier"and "Ignition Barrier" ratings. DC315 is a Certified Warnock Hersey listed and rated product which has passed certified testing for both the(UL- 1715) 15 minute Thermal Barrier and the NFPA 286(AC-377 standards)as an Ignition Barrier. DC315 applies as easily as regular latex paint and being a water base cleans up in a snap. Using DC315 will satisfy code compliance on"15 Minute Thermal Barriers"and"Ignition Barriers"on your next foam job means: • Large single coat spread rate • UL 1715 Thermal Barrier ■ (88.88 sq.ft./gal @ 18 mils wet and 12 mils dry)coverage rate of 1.136 gallons(4.3 Q per 100 square feet(9.3 M) • NFPA 286 (AC377)Attic Crawl Space Ignition Barrier ■ (130 sq.ft./gal @ 12 mils wet 8 mils dry)coverage rate of.77 gallons(2.9 Q per 100 square feet(9.3 M) • Reduced labor cost,reduced material cost and higher profits • Fast turnaround time • Easily applied with a sprayer,brush or roller • No complicated mixing-just stir the paint before application . • No waste • Fast and easy clean up of our water based latex product,tools&equipment • Will not gum up or block spray equipment • Passed strict EPA–VOC and AMQD tests —.- • No formaldehyde Qi15 • Non Toxic,Low Vapors, Low VOCs less than 50 making DC-315 a Green Product • Earn 2 LEED points for using DC-315 • Two year shelf life • Certified Code Compliant Coating RECOMMENDED USES:This product is designed for use on interior polyurethane foam surfaces. USED BY:Schools,Colleges, Nursing Homes,Child Care Centers, Hospitals) Penal Institutions,Apartments, Hotels, Factories,Warehouses, Retail Stores, Restaurants, Utilities, Railroad and other Transportation Companies,Oil and Chemical Installations, Military Installations,and other facilities where fire retardant coatings are required. PRECAUTIONS: Adequate ventilation must be provided during and after application until the coating has dried.Avoid breathing vapors or spray mist.Close container after use. Read MSDS before opening containers. RHH Foam Systems,Inc 1 1-800-657-0702 www t hhfoamsystems com . �C315 SURFACE PREPARATION:Can be applied directly to fully cured polyurethane foam surfaces.All surface preparation should be carried out in accordance with good painting practices. Remove all loose, peeling or powdery existing paint from the surface.All dirt,grease,oil,wax,and other foreign matter MUST be removed with a detergent,rinse surface thoroughly with clear water,and allow drying. APPLICATION EQUIPMENT: DC315 can be applied by brush, roller or airless sprayer - Brushing: Use top quality polyester/nylon blend brushes such as those supplied by Purdy,Wooster,or equivalent - Rolling: 3/8" polyester blend nap roller covers generally work well Spraying: Pump: (Graco)for best results use Graco 795 airless sprayer,with a minimum 2000 PSI • Tip:526—529 or equivalent • Filter:60 mesh • Hose: Use minimum size of 3/8"airless spray line for the first 50'from pump - Airless Spray: • Fluid Pressure: ........................2000 PSI or higher • Strainer: ..................................60 Mesh • Fluid Hose: ..............................3/8 diameter with a 1/4"whip • Tip: ...........................................021-.029 - Conventional Spray • Air Supply....................................12 CFM,50 psi at nozzle, • Fluid..............................................15-20 psi • Gun..........................................Graco 217-800 to 217-816 • Type.............................................External Mix • Reduction ....................................Up to 7% APPLICATION:Stir thoroughly and apply WFT per test. Do not apply in temperatures below 50°F(10°C). CHARACTERISTICS: ASTM E 84 Testing Flame Spread of 5, Smoke Development of 300 Finish Flat Color Off-White Spreading Rate For 15 minute Thermal Barrier(88.88 sq.ft./gal @ 18 mil wet and 12 mils Dry) coverage rate of 1.136 gallons(4.3 L)per,100 square feet(9.3 M2) Spreading Rate For AC377 Attic Crawl Space(130 sq.ft./gal @ 12 mil wet 8 mils Dry)coverage rate of 77 gallons(2.9 L)per 100 square feet(9.3 M2) V.O.C. (47 g/1) Volume Solids 65% Drying Time @ 77°F&50%RH To touch in 1-2 hours,to recoat 2-4 hours Type of Cure Coalescense , 'A PND ARC Do Flash Point None ��\� N /<<9/��� Reducer/Cleaner Water Shelf Life 2 years(unopened) =•T►� Packaging 5 gallon pails i Shipping Weight 5 gallon pail—58 lbs N� Application Brush, roller,conventional and airless spray '9X 03081 Q� ccoF NE�y RHH Foam Systems,inc 1 1-800-557-0702 www rhhfoamsystems corn r - " �o�.�pF SOUjyolo # TOWN OF SOUTHOLD BUILDING DEPT. °`�courmNE'' 765-1602 INSPECTION , [ ] FOUNDATION IST [;/ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING R ARKS: cXfas'svyc-"-- i �- .v- DATE INSPECTOR ho�aOF 50Ulyo� # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 ���j��' g 1 NSPECTIO � � [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [�] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) CODE VIOLATION [ ] CAULKING REMARKS: DATE _ INSPECTOR b� SOP 50U1H �o� olo * # TOWN OF SOUTHOLD BUILDING DEPT. IOU IIS` 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I SULATION [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ CAULKING REMARKS: 4,4n, collA � / S410- DY � kvI DATE INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) y ------------------------------------ 'FOUNDATION (2ND) Al ROUGH FRAMING& � PLUMBING y INSULATION PER N.Y. H STATE ENERGY CODE 1 t � • 1IYnAA i vqi i� M/ Cup- FINAL ADDITIONAL COMMENTS JA ' ,H TOWN OF FPU1'it$OLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans x TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 7� Survey x Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined ,20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: 2639 95TH ST Approved 2 20 Mail to: EAST ELMHURST, NY 11369 Disapproved a/c Phone: 917-842-9786 Expiration ,20 mcENS Building Inspector MAR 15 2019 D APPLICATION FOR BUILDING PERMIT Date March 8th 20 19 INSTRUCTIONS 'Xq S appliccoonTMUOS be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code, and regula ion and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or n e,if a corporation) 2639 95th Street, Eas /Elmhurst, NY 11369 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder OWNER & ARCHITECT Name of owner of premises FERNANDO A. VILLA & MARIA 1. VILLA (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. 55578-MP Electricians License No. 2635E JIM SAGE Other Trade's License No. ARCHITECT 030814-1 1. Location of land on which proposed work will be done: SOUTHOLD 15 SUN LANE House Number Street Hamlet 076.00 001 County Tax Map No. 1000 Section Block 01-o' Lot � _ 1 Subdivisi2n_, "r,EST CREEK DEVELOPMENT # 1236 Filed Map No. 1236 Lot 1 & 2 2. State existing use and occupancy of premises and intended use and occupancyy of proposed construction: a. Existing use and occupancy PRIVATE ONE FAMILY DWELLING WI ]H ATTACHED WOOD DECK AND DE4QQaED PRIVATE ONE FAMILY DWELLING WITH ATTACHED WOOD DECK AND DEVREHEP b. Intended use and occupancy m 3. Nature of work(check which applicable):New Building Addition Alteration x Repair x Removal Demolition_ - Other Work_ $30,000 (Description)4. Estimated Cost " Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units 1 Number of dwelling units on each floor 1 If garage, number of cars 6. If business, commercial or mixed,occupancy, specify nature and extent of each type of use. T 'Dimensions of existing structures,'if any: Front 44.21 Rear 44.2 ' Depth 16.3 Height 15Number of Stories 1 - Dimensions.of same structure with alterations or additions: Front 44.,2 Rear 16.3 Depth 3-6.31 Height 15' Number of Stories 1 8. _ Dimensions'of entire-new construction: Front 44.2' Rear_ 44.21 Depth 16.3' Height 15' Number of Stories ?_ 9.. Size of lot: Front 95, Rear. 71.93 Depth - 96.591 10. Date of Purchase 01/30/2019 Name of Former Owner WALTER W. SCHARPF & PAULINE R. SCHARPF R-40 MEDIUM DENSITY RESIDENTIAL -11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO x 13. Will lot be re-graded? YES NO x Will excess fill be removed from premises?YES -NO x 2639 95TH ST, EAST ELMHURST FERNANDO & MARIA VIL �ress 11369 917-842-9786 14.Names of Owner of premises . . A _ _ Phone No. _ - Name of Architect FERNANDO A. VILLA Address SAME Phone No 917-842-9786 Name of Contractor_ _ Address Phone No. 15'a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO *'IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS'MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES_ NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide'topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO x *JF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF tJ y ) FERNANDO A. VILLA being duly sworn,-deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the OWNER/ARCHITECT (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith., Sworn to before me this 3 day Of MARCH 2019 7 Notary Public Np, 01 F Signature of•Appl' ant Glenn Goldsmith,President ®F'S®l Town Hall Annex Michael J.Domino,Vice-President 54375 Route 25 P.O.Box 1179 John M.Bredemeyer III '• � Southold,New York 11971 A.Nicholas Krupski Q Telephone(631)765-1892 Greg Williams Fax(631)765-6641 BOARD OF TOWN TRUSTEES iY TOWN OF SOUTHOLD Permit No.: 9622A FEB - 3 2020 Date of Receipt of Application: August 13, 2019 Applicant: Fernando & Maria Villa SCTM#: 1000-76-1-1 Project Location: 15 Sun Lane, Southold Date of Resolution/Issuance: January 15, 2020 Date of Expiration: January 15, 2022 Reviewed by: Greg Williams, Trustee ` Project Description: For the as-built construction of 6'x6' landing with steps; 4'x5' addition to existing deck; installation of open outdoor/exterior shower attached to existing house with plumbing lines connected to main house service, with a 4'x4' base at grade with drainage connected to new drywell; remove the 11.2'x18" high step adjacent to concrete patio and fill in at grade; and for the 210"x4.5' HVAC enclosure.. Findings: The project meets all the requirements-for issuance of an Administrative Permit set forth-in'Chapter 275 of the Southold Town Code. The issuance of an Administrative Permit allows for the operations as indicated on the survey prepared by Peconic Surveyors, P.C., last dated December 27, 2019 and stamped approved on January 15, 2020. Special Conditions: None. Inspections: Final Inspection. If the proposed activities do not meet the requirements for issuance of an Administrative Permit set forth in Chapter 275 of the Southold Town Code, a Wetland Permit will be required. This is not a determination from any other agency. Glenn Goldsmith, President Board of Trustees f No.SOUTHOLQ,jRUST'EES Issued T oFMA46? Mm'w' 04A ' . Date 1. 116P•10 . Address 1� SvH �.AvE, sbv�D THIS NOTICE MUST BE DISPLAYED DURING CONSTRUCTION TOWN TRUSTEES OFFICE,TOWN OF SOUTHOLD SOUTHOLD, N.Y. 11971 TEL.: 765-1892 Glenn Goldsmith,President Qf S®!/Tyo Town Hall Annex Michael J.Domino,Vice-President ,`O 1p 54375 Route 25P.O.Box 1179 John M.Bredemeyer III Southold,New York 11971 A.Nicholas Krupski cn G, Tele ne(631) 765-1892 Greg Williams Fr(631) 765=6641; - , COUlm _ A HOARD OF TOWN TRUSTEES FEB _ 7 2020 TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE # 1685C Date: February 7,2020 THIS CERTIFIES that the as-built construction of 6'16' landing with steps, 4'x5' addition to existing deck: installation of open outdoor/exterior shower attached to existing house with plumbing lines connected to main house service,with a 4'x4' base at grade with drainage connected to new drywell: remove the 11.2'x18"high step adjacent to concrete patio and fill in at grade: and for the 2'1 0"x4.5' HVAC enclosure; At 15 Sun-Lane, Southold Suffolk County Tax Map #1000-76-1-1 Conforms to the application for a Trustees Permit heretofore filed in this office Dated August 13, 2019 pursuant to which Trustees Administrative Permit#9622A Dated January 15, 2020,was issued and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the as-built construction of 6'x6' landingwitb steps: 4'x5' addition to existing deck:. installation of open outdoor/exterior shower attached to existing house with plumbing lines connected to main house service,with a 4'x4' base at grade with drainage connected to new dr_ywell-, remove the 11.2"x 18"high step adjacent to concrete patio and till in at grade; and for the 2'l 0"x4.5' HVAC enclosure. The certificate is issued to Fernando &Maria Villa owners of the aforesaid property. f � u of +r APPLICATION w PAGE- I of a TOWN OF SOUTHOI_D FLOODPLAIN DEVELOPMENT PERMIT APPLICATION This form is to be filled out in duplicate. SECTION 1• GENERAL PROVISIONS (APPLICANT to read and sign): 1. No work may stars until a permit is issued. 2 Tho permit may be revoked if any false statements are made herein. 3. If revoked, all work must cease until permit is re-issued. 4. Development shall not be used or occupied until a Certificate of Compliance is issued. S. The permit will expire if no work is commenced within six months of issuance. 6. Applicant is hereby informed that other permits may be required to fulfill local,state and federal regulatory requirements. 7. Applicant hereby gives consent to the Local Administrator or his/her representative to make reasonable inspections required to verify compliance. 8. 1,THE APPLICANT.CERTIFY THAT ALL STATEME HEREIN AND IN ATTACHMENTS TO THIS APPLICATION ARE,TO THE BEST OF MY "ILEDGE,TRUE AND ACCURATE. (APPLICANT'S Sk,*ATURE) SECTION 2 PROPOSED DILOPMENT(To be comoietcd by APPLICANT} NAME ADDRESS TF-LEEHPNE APPLICANT FfiW400 VI 15 St)N /,►W SvvT�1oL� N �8�29�a6 BUILDER srNl�d�rM�/l36 eyWA NDo Vdh. 26 37 9,7W 5 :r �' ENGINEER AeCW I T67c-r- /1 tl �ROlECT L =Ohf_: To avoid delay in processing the application, please provide enough information to easily identify the project location. Provide the street address, lot number or legal description (attach) and, outside urban areas, the distance to the n=est intersecting road or well-known landmark. A sketch attached to this application showing the project location would be helpful. WE-sr nW M4P,1, Sia-,nO"�` t7-;P6 BwUt Dr:l/ GoAF /z 3 6. �il� MAP '36 . )QTS /8 Z SEE A- FDP(93) APPLICATION PAGE 2OF4 DESCRIPTION OF WORK (Check all applicabic boxes): A. STRUCTURAL. DEVELOPMENT A FIVUY STRUCTURE- TYPE ❑ New Structure O Residential (I-4 Family) ❑ Addition ❑ Residential (More than 4 Family) Alteration ❑ Non-residential (Flood proofing? ❑ Yes) ❑ Relocation ❑ Combined Use (Residential & Commercial) ❑ Demolition ' ❑ Manufactured (Mobile) Home (In Manu- 0 Replacement factured Home Park? ❑ Yes) ESTIMATED COST OF PROJECT S30,DOD B. OTHER DEVELOPMENT ACTIVI'T'IES: ❑ Fill O Mining ❑ Drilling ❑ Grading ❑ Excavation (Except for Structural Development Checked Above) ❑ Watercourse Alteration (Including Dredging and Channei Modifica(ions) ❑ Drainage Improve eats.(Including Culvert Work-) ❑ Road. Street orTrdge Construction O Subdivision (New or Expansion) ❑ Individual Witer or Ser System ❑ Other (Please Specify)* After completing SECTION 2, APPLICANT' should submit form to Local Administrator for re%iew. SE=ON 3 FLOODPLAIN DE'T'ERMINATION be comolctcd by LOCAL ADMINI ROTOR The proposed development is located on FIRM Panel No._ . Dated The Proposed Development: 13 Is hgn located in a Special Flood Hazard Area (Notify the applicant that he application review is complete and NO FLOODPLAIN DEVELOPMENT PERMITISILEQUIRED)• • O is located in a Special Flood Hazard Area. FIRM zone designation is 100-Year flood elevation at the site is: Ft. NGVD (MSL) ❑ Unavailable ❑ The proposed development is located in a floodway. FBFM Panel No. Dated ❑ Sec Section 4 for additional instructions. SIGNED DATE APPLICATION ,v ` PAGE 3 OF a SECTION 4: ADDITI NAL INFORMATION RE UIRED To he completed by LOCAL ADMINISTRATOR The applicant must submit the documents checked below before the application can be processed: ❑ A site plan showing the location of all cidsting structures, water bodies, adjacent roads, lot dimensions and proposed development. ❑ Development plans,drawn to scale, and specifications,including where applicable:details for anchoring structures,proposed elevation of lowest floor(including basement), types of water resistant materials used below the ftrst floor,details of f]oodproofing of utilities located below the first floor and details of enclosures below the first floor. Also ❑Subdivision or other development plass (If the subdivision or other development exceeds 50 lots or 5 acres,whichever is the lesser, the applicant trust provide 100-year flood elevations if they are not otherwise available). ❑ Plans showing the extent of watercourse relocation and/or landform alterations. ❑ Top of new fill elevation Ft. NGVD (MSL). ❑ Floodproofing protection level (con-residential only) Ft.'NGVD (MSL). For floWi,koofed structures, applicant must attach certification from registered engineer or architect. ❑ Certificationfrom a registered engineer that the proposed activity in a regulatory floodway will not result in any increase in the height of the 100-year flood. A copy of all data and calculations supporting t-his finding must also be submitted. ❑ Other: SECTION 5 PERMIT DETERMINATION (To be completed by LOCAL ADMINISTRATORI I have determined that the proposed activity. A.❑ Is B.❑ Is not • in conformance with provisions of Local Law . 19 The permit is issued subject to the conditions attached to and made part of this permit. SIGNED , DATE J BOX A is checked, the Local Admiaistrator may issue a Development Permit upon payment of designated fee. if Oecked, the Local Administrator will provide summary Of written summaof deficiencies. �°►pPltcan X 8 is cht may revise and resubmit an appfication to the Local Administrator or may request a bearing from the Board of Appeals APPLICATION a _ PAGE 4 OF 4 APPEALS Appealed to Board of Appeals? ❑ Yes ❑ No Hcarmg date: Appeals Board Decision --- Approved'? ❑ Yes ❑ No Cooditioms SECTION G AS-BUILT ELEVATIONS (To be submitted by APPLICANT before Certificate of Compliance is issued) The following information must be provided for project structures. This section must be completed by a registered professional engineer or a licensed land surveyor (or attach a certification to this application). Complete I or 2 below. 1. Actual (As-Built) Elevation of the top of the lowest floor, including basement(in Coastal High uazard cas, bottom of lowest structural member of the lowest floor, cxcluding piling and columns) is: FT. NGVD (MSL). 2. Actual (As-Built) Elevation of floodproofing protection is FT. NGVD (MSL). NOTE: Any work performed prior to submittal of the above information is at the risk of the Applicant. SECTION 7 COMPLIANCE ACTION (To be completed by LOCAL ADMINISTRATOR) The LOCAL ADMINISTRATOR will complete this section as applicable based on inspection of the project to ensure compliance with the communitys local law for flood damage prevention. INSPP,CI'IONS: DATE BY DEFICIENCIES? OYES ONO DATE BY DEFICIENCIES? OYES ONO DATE BY DEFICIENCIES? 17 YES ONO SECTION 8• CERTIFICATE OF COMPLIANCE(To be comt1leted by LOCAL ADMINISTRAT_ORl Certificate of Compliance issued: DATE: BY: Attachment B I SAMPLE CERTIFICATE OF COMPLIANCE for Development in a Special Flood Hazard Area • TOWN OF SOUTHOLD CERTII~ICATE OF COMPLIANCE FOR DEVELOPMENT IN A SPECL4.L FLOOD HAZARD AREA (O'W'NER MUST RETA.IN THIS CERTIFICATE) PREMISES LOCATED AT: PERMIT NO. PERMIT DATE OWNERS NAME AND ADDRESS: CHECK ONE: ❑ NEW BUILDING ❑ EXISTING BUILDING ❑ VACANT LAND THE LOCAL ADMINISTRATOR IS TO COMPLETE A. OR B. BELOW: A. COMPLIANCE IS HE, CERTIFIED WITH THE REQUIREMENTS OF LO CAL LAW # , 19 SIGNED: DATED: B. COMPLIANCE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # , 19-, AS MODIFIED BY VARIANCE # , DATED SIGNED: DATED: C/C(93) i Scott A. Russell 10So k ATO IR .M WATIEK MANAGEMENT SUPERVISOR M�A��a _ SOUTHOLDTOWN HALL-P.O.Box 1179 Town of Southold 53095 Main Road-SOUTHOLD,NEW YORK 11971 0 CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET : (TO BE COMPLETED BY THE APPLICANT ) DOES TMS PROJECT INVOLVE ANY OF THE FOLLOWING' (CHECK ALL THAT APPLY) Yes No ❑OA. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑KB. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑((C, Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑ D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑ E. Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. ❑[XF. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number'. Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department wi-your Building Permit Application. S.C.T.M. #: 1000 Date APPLICANT (Property Owner,Des4e,�, ,Co/nt/ra�ctor,Other) District NAME: A �V/ »moo Section Block Lot 5� ""'x FOR BUILDING DEPARTMENT USE ONLYContact Information I-4—8 Reviewed By: f - - - - - - - - - - - - - - - - Dae: �! Property Address/Location of Construction Work: — — — — — — — — — — — — — — — — 115 G u� �N� I � —[�'Approved for processing Building Permit. — — — J 50V*�L.!) Stormwater Management Control Plan Not Required. ElStormwater Management Control Plan is Required. (Forward to Engineering Department for Review.) FORM " SMCP-TOS MAY 2014 D D DEPARTMENT- Electrical Inspector- TOWN nspector �o ¢rye TOWN OF SOUTHOLD Hal (BAR 1 T ex - 54375 Main Road - PO Box 1179 �"��1� • Southold, New York 11971-0959 4, �O1 .� � 4T jpp.�ione (631) 765-1802 - FAX (631) 765-9502 TOWN O]FSOUTUID:,�ger richert(cDtown.southold.ny.us APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: Company Name: <97 21- Name: Name: License No.: 3 / email: Address: J- �'' Phone No.: s JOB SITE INFORMATION: (Alt Information Required) Name: Address: Cross Street: Phone No.: email: BIdg.Permit#: -� Tax Map District: 1000 Section: Block: Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) Circle All That Apply: Is job ready for inspection?: YES Fina( 1 Rough In Do you need a Temp Certificate?: ES / NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: _ A # Meters Old [ulster# New Service- Fire Reconnect- Flood Reconnect- Service Reconnected - Underground -Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Forrn.xis _ �' �UFFOt�ea Town Hall Annex �� ��4 Telephone(631)765-1802 a 54375 Main Road Fax(631)765-9502 P.O.Box 1179 W Southold,NY 11971-0959 i 41 BUILDING DEPARTMENT NOTICE OF UTILIZATION OF TRUSS TYPE'CONSTRUCTION, PRE-ENGINEERED WOOD CONSTRUCTION AND/OR TIMBER CONSTRUCTION Date: �( Owner: f pYL AN DO g MA<hft_ VILLh Location of Property: .5 SUN AAA/E , SOU T#off Please take notice that the (check applicable line): New commercial or residential structure Addition to existing commercial or residential structure Rehabilitation to an existing commercial or residential structure ? to be constructed or performed at the subject property reference above will utilize (check applicable line): Truss type construction (TT) Pre-engineered wood construction (PW) Timber construction (TC) in the following location(s) (check applicable line): Floor framing, including girders and beams(F) Roof framing (R) Floor and roof framing (FR Signature: Name(person submitting this form): r-- A N O V Capacity(c(check applicable line): i' Owner Owner representative TrussReg15.docx Effective 1/1/2015 SUR vEY _.OF LOTS 1 ,2 MAP OF 'WEST CREEK DEVELOPMENT' EEK _ FILED JULY 6, 1937-FILE NO. 1236 ;� 000 A T BA YVIEW "E 50.55 TOWN OF SOUTHOLD OV36'3 , Tip ow- SUFFOLK COUNTY, X Y, ��•93 a,�.r ° wO°° 1000-76-01-01 W TSE �-� wmow. n. SCALE: 1'-20' �.1g' LOT ' LOT AUG. 23, 1990 N w T� s y r# !7� DECEMBER 27, 2016 l z cli It W�TM w° LOT zoNE A� � cow JANUARY 17, 2019 (CER77RCA77ONS) � wooD Ker. POf .covat — N �Z� wAl.is f ON 4+ Rln►r; F�oao %' �'. 1. . 529 wo1&0 0,CA_ �Jv�� rOAc� G 2 DECK -Lcem 44.2 O r CN as y 1-STORY � r m rr M.H.w.M. ppc � FR. HOU5E ° e r 10011, lµ TOP DANK � 44.2' O�!O _ PORGi DEGC PI—MITING ! k.0, f? / AT i .Oj ry µ STOPS + �� IfYG GRADE PIrE � PAP IP�i� TIMZONE to's, wood N79.45'50-w WALKWAY o . 95.00' WAS SUN ZANY 579.45'50"E �UNpA45.0p, (C�l�AS5/p/RT) �D� • PIPE ����OF NEW9-0, ■ - MONUMENT - CERTIFIED TO- �' EPz� FEKNANDO A VILLA CD � " FLOOD ZONES FROM FIRM 36103C,0166H MAR I A V I LLA SEPTEMDER 25, 2009 CONTINENTAL AD5TKA%T LLC, AM TKU5T T I TLE I N5URANGE COMPANY PATK I OT ONE MORTGAGE DANKEK5, LLG -. - `-- 'L/C. NO. 49618 ANY ALTERATION OR ADD17ION TO THIS SURVEY IS A WOLA77ON PEC C^l$ YC. ' OF SECTION 7209OF THE NEW YORK STATE EDUCATION LAW. EXCEPT AS PER SEC710N 7209-SUBDIVIS/0N 2. ALL CER71FlCAT10NS (631) (� (631) 765-1797 AREA=6,733 SO. P. HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR1230 TRA VELER STREET WHOSE SIGNATURE APPEARS HEREON. to TIE LINE SOUTHOLD, N.Y. 11971 ®—��� - -. - - SV.L Y I E.L 4!y LOTS 1 & 2 MAP OF e WEST CREEK DEVELOPMENT" FILED JULY 6, 1937 FILE NO. 1236 SE CR G00 0 ��eoo AT BA YVIEW 5().5!5 E5 —� TOWN OF SD UTHOLD "a'•36�3' T } SUFFOLK COUNTY, , ++�A° O° 1000-76-01-01 W --`--J ',0 ", WOOo� �w "' SCALE: 1=20' �. N 4.�g'0 °, .. nv LOT 4�"a' LOT AUG 23, 1990 ' "'00 ° O o O N n ,k� X - WTD y worms �a coNc.cO v� DECEMBER 27, 2016 z `f:- LOT ZONE q� JANUARY 17, 2019 (CER77FICA77ONS) (D / (E�.e FEET) °j MARCH 21, 2019 (REVISIONS) WOOD RET. if con c c O1� _!_. _— JULY 29, 2019 cd co` 6 • •294 WA►L5 ON 4'4 RING i�INir E SEPTEMBER 25, 2019 (WOOD DECK REVISED) .` co(A 5 WOOD OCTOOER 18, 2019 (WOOD DECK REVISED) �o° N6g6 STOOP c a - 3'0DECK �' DW. CONNECTED �r DECEEMBER 27, 2019-(DRYWELLS ADDED) OEGK aTO ROOF GUTTER OY 41 IL2' DOWN SPOUTS. a4' _...- 1�STOR Y m pa M.H.W.M. pQ(.% FR. HOU5E mW� 0 00 TOP QAW SHWR IM 442• o a O __---- u: z / R DEGOI�p PI-�11r1 NG 4 GRADEFLAT y `0 /M 5TON8 + TIAL 1�7GE- PUMP +� I 1 7 PI GRAVEL WOOD Q ' I JAN O _020 Z 'T15 PE, lO B PARKING ZONE 'X" FENCE .� 00.�°i OVEW N79'45'50, A ALIcwAyE ry 3W4 X 4' DEEP - BLUESTONE 0 C4 TO ROOF NGUTTER TED PGRAVE-ON 9`5.00 WATER® DOWN SPOUTS. ROW OF 4'X4' PLANTINGS, ,' OUT SHWR DRAJNS WOOO.C.Q TIMBER EDGE Sig`IS 5p"E TO DRYWELL 0 45.p0, LANkPA -5/C5/R T) V. APPROVED BY . = PIPE .'BOARD OF 'i RUSTEES ■ = MONUMENT CERTIFIED TO, TOWN OF FEKNANDO A VILLA FLOOD ZONES FROM FIRM 36103G0166H MARIA VILLA + DATE fav : "`� SEPTEMBER 25, 2009 CONTINENTAL A55TRACT LLC, « Z020 AM TKU5T TITLE IN5URANGE COMPANY PATR I OT ONE MORT6,AGE 13ANKER5, LI—C, 1 AS. LIC. NO. 49618 4NY AL7ERA7/0N OR ADD17ION TO THIS SURVEY IS A 40LA710N - 7F SECTION 7209OF THE NEW YORK STATE EDUCATION LAW. PECON/C-SURVEYORS, P.C. D(CEPT AS PER SECnON 7209-SUBDIVISION 2. ALL CFRnRCATIONS C/� 'n ^ (631) X 90920 FAX (631) 765-1797 'IEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF AREA=6,733 80.�FT• P.O. BOX 909 SAID MAP OR COPIES BEAR THE IMPRESSED SEAL OF THE SURVEYOR 1230 TRA VELER STREET WHOSE SIGNATURE APPEARS HEREON. to TIE LINE SOUTHOLD, N.Y. 11971 90-267 LU1;, ; 1 �c MAP OF 'WEST CREEK DEVELOPME FILED JULY 6, 1937 FILE li ,10, God �_�eoO SE ` _! AT BA YVIEW�� 50.55 TOWN OF SO UTHOLD M 1181'36'3 }} Tom"° N Y — � �T SUFFOLK COUNTY,; ' � w000, 1000-76-01-01 W2.3 SCALE: 1'-20' co— `ova'„- LOT + �' LOT AUG. 23, 1990 c!N^ X4 2"." v , d ' % © �y# C04c'c0v= °�� DECEMBER 27, 2016 � w LOT NE ZO JANUARY 17, 2019 (CER17F7CA77ONS) co• W Q 0 (EL.6 FE TJ •�1' �3 WOOD Rei '• �j2 + V: W/II.LS ON90 LOA ,, 140 r ti 2 PET ,C)FXK $6 / 44.2 — 1� TORY M.H.W.A�. ear• 4 � �� FR. HOU5E TOr d1A1C ° 5� 16L �2• y1 l�v �v/ o �l► DECKR-NVTINGAT �f.0. �It� - - O- 5T01�-+- ` - -- TIAL L j/rlpE i GI,Rp PARKING TIMI ZONE X• yN l0'S WOpa LLr FRACK N79.45�50-W �"�"c�nr� lY► o� 95.00' WA - S7945 .E 50SPE - - - -- - -- -- -------- --- - (UA jj 45.00' R � ASS/pj ! A VL�'1�) , R T) IS • • PIPE SOF NEiv rO ■ • MONUMENT GEKT I F I ED TO- CO .� M E TZ q&^� vc ` FEKNANDO A VILLA �.� c� FLOOD ZONE5 FROM FIRM 36103G0166H /l G V U MARIA VILLA �� 1 5EPTEMDEK 25, 2009 CONTINENTAL. AI35TKACT LLC AM TKU5T T I TLE I N5URANGE COMPANY . PATKIOT ONE MORTGAGE E5ANKER5, LI-C, .ILIC. NO. ANY AL7ERA7ION OR ADDI77ON TO THIS SURVEY IS A VIOLATION PEC .0 OF SECTION 7209OF THE NEW YORK STATE EDUCATION LAW. EXCEPT AS PER SECTION 7209-SUBDIVISION 2. ALL CERNF7CA7)ONS �-� (631) 63., 65 - HEREON ARE VALID FOR THIS MAP AND COPIES THEREOF ONLY IF AREA=6 7�3 80. r 1 . P.O. BO SAID MAP OR COPIES BEAR 7HE IMPRESSED SEAL OF THE SURVEYOR1230 TRAVELER STREET no_, WHOSE SIGNATURE APPEARS HEREON. to TIE LINE SOUMOLD, N.Y. 11971 c� EXTERIOR INTERIOR I 3'-0" 3'-0" NEW 2X6 CEDAR < I LANDING 4 RISERS RAILING TYP EXISTING FIXED ! 3"X8" 12" 12" 12" 2'X12"X6" WINDOW SUPPORT CEDAR TREADS 2 1 s'V i EXISTING I V) = co: 1 ' ', 1,'Aja� � � 6'-0"X6'-8" 12 X6 X('_ I_ _ U) SLIDING DOOR -- EOAR; - -- :mm) I Li EXISTING FIXED I NEW 2X6 CEDAR WINDOW 4"X4" POSTS TYP RAILING TYP `;>j,' 1 I PILA=1-01,N VIEW ' INTERIOR EXTERIOR —EXISTING NEW 2X6 CEDAR ^� / dP 6' 0"X6' 8" 3'-0" RAILING TYP SLIDING DOOR LANDING "t X6" � b CEDAR TREA NEW 2X4 CEDAR 2"X6"X6' CEDAR- 3"X8" EDAR 3"X8" SUPPORT ckf - N W 4"X4" POSTS _ N TREATED WOOD _ ;`x EXISTING CELLAR �,�\\,\��\,. Ile P 0.308 OP OF NES 2 SECTION 1/4"=1'-0" 15 SUN LANEDRAWING TITLE: OWNER/ARCHITECT SCALE: AS NOTED SOUTHOLD NY 11971 NEW STEPS AND LANDING FOR EXISTING SLIDING DOORS FERNANDO VILLA DATE: 07/01/19 EXTERIOR INTEID 3'-0" 3'-0" NEW 2X6 CEDAR EXISTING FLANDING 4 RISERSRAILING TYP3"X8" 12" 12" 12" 2'X12"X6" WINUPPORT CEDAR TREADS r , 2 1 FEBI 20 EXISTINGI ¢ O o Lig? � r O ? r SLIDING DOOR —MIAR , - � w z d ME o „ N J EXISTING FIXED NEW 2X6 CEDAR WINDOW 4"X4" POSTS TYP RAILING TYP PLAN VIEW INTERIOR EXTERIOR EXISTING NEW 2X6 CEDAR 6'-0"X6'-8" RAILING TYP SLIDING DOOR LANDING- CABLE RAILS @4" 2'X12"X6" CEDAR TREADS 2"X6"X6' CEDAR 3"X8" SUPPORT AUL - - V) 4"X4" POSTS TREATED WOOD EXISTING CELLAR ARC&/T 0p0 V/<C� (L/ �tB SECTION 2 114"=1'-0" � 030a'`°` FOF 15 SUN LANEDRAWING TITLE: OWNER/ARCHITECT SCALE: AS NOTEC SOUTHOLD NY 11971 NEW STEPS AND LANDING FOR EXISTING SLIDING DOORS FERNANDO VILLA DATE: 08/08/19 BUILDING DEPARTMENT / SUBMISSION �REE� l /000, G4�SE Q C A300 / SEE DETAIL PAGE NORTH ELEVATION SK-01 07/01/19 A300 18-0 1 revision Date EXISTING WOOD No, • PLATFORM WITH STEPS METAL DOORS ACCESS TO MEC%. BASEMENT EXT. WOOD STOOP AND STAIRS DW 2EW WIND -- _ - - -- o / 1 8/8/2019 B N � UP A300 _ „ 5,_2, _- - _ -- - - - - --- - ' TRUSTEES PERMIT SUBMISSION - - - ----. 4R NEW W00 • - A 1� Wood - Af�QING 1 Rear-DeckXlto reain 003 --- - - • 1 NEW SLIDING LASS co NEW SLIDING -_ - --. _. - - - NEW / _� GLASS DOOR - — - — DOOR 12'X6' 4 . " 3 2X4 3 2X4 WINDOW (3) 2X4 _ • 54" 12 9_ (3) 2X4 POT 12'-D" 2, 1,. POSTz POSTo^ -- - ^1 POST •. Ll so w-loo I " 34'-2" W-103.1 4 X 4 0 1 3/4" X 5 ' • LV EADER N 1/2" LVL HEADER j NEW WINDOW LVL HEADER NEW BARN / gp • 6'-0"X5'-2" DOOR W 104.3 (2)1 3/4"x5 1/2" -•1 CM I I I Z LVL HEADER RELOCATED EXITING WOOD Dlnln room E EXISTING WOOD 103 FLOOR TO BE I NEW BLUESTONE E , • � A300 (3) 2X4 POST STOVE REMAIN NEW POCKET ' FLOOR OVER A300 NL=VLivin Room �. DOOR 24"X80' EXISTIMc ARCHITECT: 3F 104 NEW WALL :: CONCRETE _ Bedroom 1 �, Z FERNANDO VILLA — — 0 / • ^ `1 — — — — 1 101 _, -- ! - ; - g 26-39TH STREET EXITING WOOD I I f WALL ¢ • QUEENS, NY 11369 FLOOR TO REMAIN I I I 1 ! PATIO 917.842.9786 • New ReconfiguredNew L -JL JL J 005 Kitchen Bathroom � villafernando5@gmail.com _ 102 0 • AT GRADE ' / • _ EXISTING WOOD A300 NEW WINDOW NEW ELECTRICAL j A300 RAMP p 12-1p"/ \ I p • - 6'-O"X5'-2" = T —T— _Z_ T PANEL (2) 1 3/4"x5 „ t - 1/2" LVL HEADENEW ENTRY DOOR REF • DW Q Q LST C 0 W-104. " �Q BENCH L4 - 36"X80" o o I, i W -- - - W-103. - _ W 101 Ex' I 0 102 Sh d 3Is'n -4 6-0 2- - 4'-3" 4,_5 „ / 006 _ - ENTRY - - - - • NEW WINDOW �l �' NEW IND0 r - - PLANTING AREA - " W BLUE AT GRADE OR/ST00 4'-3"X2'-4' / 2'-6 -2" - - _ I - - '� - -- F E Q - 3 :020 -- ON GRADE DECK A 00 � 004 I,�I _ EXISTING WOOD - - - - - - - DECK OUTDOOR HVAC b �bO�O -- AT GRADE - - - - v -- - - - UNIT WITH WOOD / - - --- - - ENCLOSURE ' - GRAVEL -. • rc ' A200 / EXISTING @300 • PLANTING AREA SOUTH ELEVATION Front EXISTING STONE & Yard , 001 • GRAVEL PARKING B _ - ! • !y A200 -WOOD WALKWAY ' Proposed Floor Plan Renovation AT GRADE / Orient and affix BIS PROPERTY LINE 0 job number label heieA 1 • r-_-__- - v --------- Project: VILLA'S RESIDENCE -- RENOVATION -- 15 SUN LANE SUN LANE Southold, NY 11971 Title: AS BUILT FLOOR PLAN 1-4 � �� SEA Rt1bTA C DATE: 03/07/19 2C? �cj(�G ENDO �� y�� PROJECT No: , r �' FT K BY: FV " .7G No: - < A-101.00 �� J" CADO FILE No: of n BUILDING DEPARTMENT C SUBMISSION TOWN OF SOUTHOLD D 1,1: ,.P. W NOTIF. 765-1802 P V, F 0 I30T*_D C 2. 1 T, ,, PROJECT INFORMATION: 15 SUN LANE, SOUTHHOLD, NY 11971 3. 1 4. FN,"_ - 'UST PLOT DIAGRAM B C I E F Of). �RVJAG ALL 006N,J_IRIKI I 1"I'!f",l_.L 1,,r-ET T!--!r7_ 1 100 -QlJ'rPk,!7-"TS OFTHFCODES OF,N17" RF COUNTY TAX MAP # 1000 SECTION 076.00 -E. [Ii:�,'! FRES�ONN;H� FO�R YO-' ST ,l CO""TRUCTION EFIFIORS. BLOCK 01 .00 1 GN Of, LOT 001 CHPP of- SUBDIVISION WEST CREEK DEVELOPMENT #1236 A 00A COMPLY WITH ALL CODES O� anal NEW YORK STATE & TOWN CODE FILED MAP 1236 rl LOT 1 &2 il -r, AS REQUIRED AN ��, O, PARCEL leatlaft J DIOV-2RA— PARCEL 1000-76-1 -1 Addid aired. SO(CH Vv -Be p ZONE/DISTRICT R-40 MEDIUM DENSITY RES. may eq- BOAR LOT AREA 6,733 SF SOP41a�- TPUSTLS CLASS: ONE FAMILY YEAR—ROUND RESIDENCE EXISTING 1 STORY FAMILY HOUSE AREA 720.46 SF EXISTING 1 STORY DETACHED FRAME SHED 154.39 SF TOTAL BUILT SF 874.85 SF Revision Date Revision Date No. No, 0) LJ (0 0 0) —--——————————— 0 WOOD RET. T WALLSMM avow 1> 18.09 y1 , 0 ""EXISTING WOOD DECK 4- n 0.5 ARCHITECT CP FERNANDO VILLA 26-39TH STREET 00 . —STORY LU 0 r--) cl:� - —4), J� QUEENS, NY 11369 AMP HUUSE < 917.842.9786 0 71 n 0 villafernando5@gmail.com .2 _J WOODPLANTING OD DECE DECK ;0 n T GRADE AT 0 )�, 7" o GRADE (0 PLANTING NE STO Q) 0� �D" (c<rfi GRAVEL ---WOOD 0 PAR KING WALKWAY /1D AT GRADE N 7 9 °4515011w 95. 00 S79 °45 '5 0 E 45, 00 ) T T 7-7 Z/ 70�,, T y "T f V J GRASS/DIRT Project: VILLA'S RESIDENCE ALTERATIONS 15 SUN LANE Southold, NY 11971 Title: PLOT PLAN SEAL I§IGNATUDATE: 03/11/19 ?,ED A C PROJECT No: �DRAWN BY: 0,A HK BY: FV TG No: CARO FILE No: of 0 BUILDING DEPARTMENT SUBMISSION TOWN /QTR \0-- OF SOUTHOLD . PRO • / EK lw�S� �R�EKI a C /A300 NORTH ELEVATION A300 / Revision Date Revision Date No. No. METAL DOORS ACCESS TO MECH. BASEMENT _ B A300 • xis - _ ....... .,_ bdA oc- A300 \ 'Y 003 NEW SLIDING C LASS ................._................._..............__._... - DOOR...12.X6. _....... - - POST X4 ... ..... ( )3 271 ". W-104.1 (2)1 3/4"x7 1/ " -103.1 -100 ! " ''`:;?} '�.•,. ,`, , ',•, m . r; vd: n n 'Jr O a i ._......_._._._. ........-. j _. _._ ...... LVL H ER " . (2)1 3/4 X 7 1/4 1 2 LVL HEADER r :. ,•. NEW WINDOW EXISTING WOOD LVL HEADER NEW BARN M / ,. ::. .' 6' 0"X5' 2.. DOOR STOVE TO REMAIN A! Y ' �a:..• i 104.3 (2)1 3/4"x5 1/2" \ z LVL HEADER Dinin room EXITING WOOD I i ; •` :r:' `� •f. ' ... �. j FLOOR TO BE I ,y`:.; ' A3i0 Q ga_____• I I ,, :4 •.1i,.42 +}•''•'• 'sy•~ •• ZA o A3C�0 (3) 2X4 POST 103 • < `'• • E REMAIN NEW POCKET `}` • `'r "''t `;' ''` L Lavin Room L► DOOR 24"X800� ' ' ''• ARCHITECT Fl-0-4-1 NEW WALL Bedroom 1 :i• . •'i' '� �''t'`: `}j o FERNANDO VILLA 101 ,; :: : 'iotiRl, ;`rio::.:�.,L: o Q 26-39TH STREET ` r;,•. ;, NEW _ 'r ,�,.'„. 'GHANf �..::.:'.'•:;-. � ExmNc wooD , — - � FLOOR TO REMAIN WALL �''1';:`".�. . x" :.;'`�;1: .':?.•• •: `l � QUEENS, NY 11369 .. ; .: �•�. :..• ; :;`�: 917.842.9786 New - - - - - - ---- - New Reconfigured ;` Kitchen Bathroom .t ,:.` ,. 4' ' : :r villafernando5@gmail.com 102 y�•.�•' _ EXISTING WOOD G A300 -- 1NCE�W- WINDOW INDOW �►' r 1032 n\_--IIOD f T T ! �:;�•':'�:!;::.l`»>.:''�: '* p 0RAMPRLEAGNFY : A.30 .._..._...__....-----.._....._._-----.............. `I .....6-0"X5-2 ..._ -- ---- DOOR - NEW ENTRYDOOR/2" LVL HEADER DWREF LOSET CLOSET(2) 1 3/4"x5 36"X " BENCH 4. i r. _ .. W 103. W i02 ENTRY 006 (3) 2X4 POST/ ' fi..........._......._................._........_...._........... / ! NEW WINDOW - PLANTING AREA 2'-6"X5'-2" / EXISTING DECK ' ON GRADE A00 J f J3 NEW WOOD FLOOR 004 TO MATCH EXISTING >> �%/` 1/g/ f C / PLANTING AREAA200 A300 SOUTH ELEVATION �J Front Yard Q� EXISTING STONE & 001 GRAVEL PARKING B A200 Proposed Floar Plan Renovation / _PROPERTY LINE J Project: o� VILLA'S RESIDENCE . ALTERATIONS 15 SUN LANE SUN LANE Southold, NY 11971 Title: PROPOSED FLOOR PLAN DATE: 03/11/19 PROJECT No: � �A DRAWN BY: CHK BY: FV t'. DWG No: - x A-101,00 CARO FILE No: of BUILDING DEPARTMENT SUBMISSION TOWN OF SOUTHOLD NEW 2X4 COLLAR NEW 2X4 COLLAR NEW 2X4 COLLAR TIES 024"O.C. TYP • _ TIES 024"O.C. TYP TIES ®24"O.C. TYP EXISTING RAFTERS -EXISTING RAFTERS EXISTING RAFTERS 2X4®24® O.C._ r "•, .2X4@24@ O.C. 2X4®24® O.C. EXISTING ASPHALT_ = TING ASPHALT EXISTING ASPHALT SHINGLE ROOF eSyFJGLE ROOF SHINGLE ROOF t< •x NEW R24 SPRAY FOAM_ i'` •` •`'-. _. - 4 SPRY TOAM NEW R28 SPRAY FOAM CLOSED CELL INSULATION . « • = r L D- LL`INSUMTION CLOSE CEILING INSULATION b ° e • fts EXISTING 2"X4" -X4■` EXISTING 2"XIINEW LVL FRAMING .�, r r " FRA ING', MING NEW SPRAY FOAM P-�FOAM " Kitchen/ CLOSED CELL----,\ e e _ �•r t NEW 3/4 FRAMING �` 0 `CELL. Din roam EXISTING 2"X4" INSULATION R24 i ■ Liv in roam ;. • . . • = • SU CE f4• 103 " Bedroom NEW 3/4 .NEW WINDOW/ _ • Franc Front FINISHED 101 NEW SPRAY FOAM Front FINISHED 104 = ( Yard Yard PLYWOOD CLOSED CELL Yard PLYWOOD Rear _ INSULATION R28 ,, l► Rear Yard xlsting Woody Rear ='` earDeck , YardYard 1 ST FL. 1 ST FL 003 s..' s.: :•!.:•: ..+ .,+6 + •+ •+ ". �_`pr€.° '�4.T'', 'Ilk \ \\ __.. `-- n n "' ■ � /// BEAM (2 2X6j " BEAM 2 2"X6 //\// ///\ //\ ";,,•`, ,,,`r � ��\ FLOOR JOISTS 2X6 X16 \ �. \. \ \ � FLOOR JOISTS 2X6 ®16 �.\\ \�\i�\� / / /� /\/\/; . / ,\ }`�..,. 3� �•. ° Basement \\/�y Existing Mech CMU FOUNDATION \\/\\,�\�\�,��\ \\�\��\//\\��\\/�!\\�� � Basement CMU FOUNDATION �\ CONCRETE W/� WALL EXISTING STAIRS Section A-ASection 13-13 Section C-C 1/4-- 2 114"=1'-4" 3 114"=V-0'E EXISTING ASPHALT EXISTING ASPHALT Revision Date Revision Date SHINGLE ROOF-\ SHINGLE ROOF Na. No. EXISTING RAFTERS NEW R24 SPRAY FOAM EXISTING RAFTERS NEW R24 SPRAY FOAM 2X4®240 O.C. CLOSED CELL INSULATION . 2X4®24® O.C. CLOSED CELL INSULATION r . . ... , ,�-: :. ,.:•. :;�:%> ::1:x' .wax°.%ti°e'`• ......." W—'- ` NEW PLYWOOD FRAMING ® EXISTING CEILING EXISTING CEILING EXISTING WOOD CEILING AND INTERIOR WALLS TO BE REMOVED _ _„ _,,, _., , - TO BE REMOVED STOVE TO REMAIN EXISTING 2"X4" EXISTING 2"X4' - - - - - - - - - - - - - - FRAMING FRAMING - ..._.,-_.._,____...- _-...-_- - - - - - - - - - - I E ti4 NEW SPRAY FOAM :°` NEW DOOR NEW SPRAY FOAM :: --'--- %� E CLOSED CELL I NON WINDOW Kitchen NEW WINDOW i NES INJNDOW � CLOSED CELL ---- / i3 INSULATION R24 FIXED �1 FIXED NEW 3/4 NEW WINDOW INSULATION R24 .:> drao I 103.2 " i t Li m NEW 3/4" Liv' Rao 101 , 104 ,-X,.-- E— F— INISHED F— FINIS l.�' ., F NEW SLI S DOOR NEW ' - t -- PLYWOOD SIJDI GLASS DOOR PLYWOOD1[ z'� �` l� DI GLASS - ` I i t 1ST FL. 19 FL. -,_ .............. _ ._. _ FLOOR JOISTS 2"X6" ®16" M"L SWAM _- :, t 4 :, �, ti 4, z ,, �. t• +. +.r. �.: ;.: +.: q. ,,, 4,,. FLOOR JOISTS 2"X6" @16" ... ... ... .. . . EXISTING PLATFORM , + + + + + • + + + • r + • + r + r •} ,+ ,r ,+ . ... ... ... ... •:;�%;'�r' � �/ // ///\%/ TO REMAIN � /�\��/\\//\\\ \/\/�\y�\\ %,\\/\\\,\�jyi' `\`�,����>: •• /\ / /i\y/\ ///i// /////i�\/ice //i��i/i� i.,/i� /ice// Existing Mech Exlsting Mecf, \,. ,y\\,\\ yy\\� ARCHITECT. �\\�/ Basement �3 Basement \\%\\��\\\ \ Basement CMU FOUNDATION FERNANDO VILLA WALL CMU COLUMN CMU FOUNDATION WALL 26-39TH STREET QUEENS, NY 11369 917.842.9786 Section D-D Section E-E villafernando5gmail.cam 4 114"=1'-0' 114"=1'-O' EXISTING ASPHALT SHINGLE ROOF TO REMAIN '_ '_ EXISTING ASPHALT •" " _ . ' *.',SHINGLE ROOF TO REMAIN e e Y _ ` (�(� r /• r r • r 003 • r P • P �- NEW WINDOW EXISTING WOOD ` 1ST FL. 2'-8" DECK TO REMAI I 1ST FL. 'D West Elevation East Elevation EXISTING WOOD STOVE FLUE TO REMAIN e r w •e,` e • i • Project: EXISTING ASPHALT SHINGLE - , � EXISTING ASPHALT SHINGLE ROOF TO REMAIN VILLA'S RESIDENCE e e > °� � •>.= • ROOF TO REMAIN -•. . ` •` ALTERATIONS - 15 SUN LANE Southold, NY 11971 ° . Title: NEW WINDOW NEW WINDOW NEW SLIDING S DOOR' A 4D FIXED NEW WINDOW- ENTRY D R EW Wll D NEW WINDO!y _ L✓' NE SLIDING GLASS C R ,�,, , Mpg', , ,. •� ti �,;• �•• r ', ; . '`. , - ,.,_•,..::�` r.� 1ST FL. �. � i, � %> Y> E.s°•, h n.., 1ST FL. _ ---]Ill �- SEAINATt� DATE: 03/11/19 i ON �VPAANDO Cy PROJECT No: i RAWN BY: CNK BY: FV South Elevp tion E � DWG No: � " EXISTING WOOD DECK 114 -1-0 TO REMAIN '9A �•,. :. ,,, ;� North Elevation 1/4"=1'-0" \_�iv r:vf cAoo FILE Na: of EXITING HANDRAIL BUILDING DEPARTMENT SUBMISSION TOWN METAL DOORS ACCESS TO MECH. BASEMENT I OF SOUTHOLD ear / ==I 003 __._..._...... - -......_...._........_..__.._..... ..... ................................. - ..._..._...._......-.........__ ....._..._................ ......_..._..._ :C" ! ham I �. 'r-104.1 EXISTING W/DR7. =tC13.1 -103. - ---? _100 :h ;:� J • •:...;: :,; �` WOOD STOVE EXISTING �, Y'-1 •+' 'r:�':•,,. `a :�r%'`:;. i 7" TO REMAIN - } l - • � •• •. _..................._......_........._____--_.__.—____.__..__._.. ....._..___.._......._-....-........... _... .. -__-_ ..,. �i-.-..._.—.___.....__.._....._..___.._.._.._._._.._.._____._..-.__.__.._._.__.__._._..___-...__.____..____�_._ _�__- -____ EXISTING 2X4®18 WITH __ _.........__...._........._ .: - 2- •� R 11 BATT TYP. Bedroom 100 ":1' '�,:;;«" '•: .:f... -.,.:;, `,::r EXITING CONCRETE :' fa •s, .... FLOOR/SLAB Din in room : .f•:.;. .' f..; �' 1 103 `H•.• ``-. .''•• .. � '. :•w •' �" Living Room : 104 - --=� _ .+r�� • V ..: ! ._.............y -'.. '_' `.-,•• •7 •`a.�s,t..• .._ ....iBedroom 1 • . •. + . .t 101 I ": �'• ''��. ';' -r:•;:••,�.•''.+�,,,,', ••*,;.; . I lath room Closet - - ,� � 102 .=� �: �`°: •' •a:':,;::.•._•,.�. s j Kitchen .Y�. ....:' �'..`` . .• 106 i 103.2 � ,,_,•' :": �::• ' �-104. :" �i ° � ��`'•" .'Y::: ��•:<:�.: :: � �.:-:; .�:�w �; • � O ° � � � -101 I .:A: ^aa :i:• '� ••''J:�•1.�4•�•`•.'•".a� � •'-. nll 103. •�`� RevisionDate Revision No. No. y ..................................._......................_._... Existing Porch �/ PLANTING AREA 105 l► F Inc. 004 I ;3 PLANTING AREA f F Front E isting Condition Floor Plan Yard 1/4"=V-0" 1001 ARCHITECT: FERNANDO VILLA 28-39TH STREET ,/_EXmNG HANDRAIL REMAIN QUEENS, NY 11369 917.842.9786 - ^ villafernando5gmail.com = � oI _ EXISTING WALL EXISTING WALL UUU "0031TO BE REMOVED TO BE REMOVE I - . REMOVE EXISTING _..._._. _...__. ........ BATT INSULATION THROUGHOUT i I l ALL EXTERIOR WALLS TYP. mod ��— — — i ; ------1 -100 '�•�:.: ,;:,,�; .•, .:-��4`"„°• Vd-104.1 � � -} 3.1 W-t 03.3 .'�•,:,� _ ';,',> _: :': :�;,. •. .�;. I _. EXISTING WOOD Bedroom 2 EXISTING ..._ = ' I WINDOW TO BE STOVE TO WIN OW SLIDING DOR I 100 ±"` _:'`" •:.`' I REMOVED REMAIN }y} �" =, ;' f:' k rt y •�' #rr. Din n rC OM EXISTING WALL 103 `. :�..` +'�:: •A I TO BE REMOVED .': ,, "`• '.j' EATIIG;:'' ;:�, ,Yy ` EXISTING WALL —_ — — — .' :'i. ';,' 0 .;:•,. Livin Room TO BE REMOVED IS G 00 _ — — — — •ti :'�� :'" . �� ''�j'; +�w.Y 104 } --- - :r ;`�•.:;:, ,,t. "',, '•-,.,F'.,`, EXISTING DOOR -; .-.. "•`." 's+�'; i' : i TO BE REMOVED T BE REtd VE :". :4 i•::,•: "";�;_ , EXISTING WALL " EXITING CLOSET TO .' ~ • . :;;. :`.• -;X:'� ,;�• TO BE REMOVED I REMOVED '�':: ''-_'r'?•:' `f' : ` .:. REMOVE EXISTING --- & Bedroom 1 =%'' `'•�. +r BATT INSULATION THROUGHOUT---\ ^ • 101 �� :' ••Y•,% '� ALL EXTERIOR WALLS T1P. ath _ +.3' _ . ~' ' '''.fi`h�• *i ISTI Kr CHE II 1 `..�'•: ;:::...: : ,.1; Ilk Closet .,: ;:'. �": �• ' 102 106TD BE REN VED 1 . • • ,. •f EXISTING EXISTING DOOR,' WINDOW TO BE y. REMOVED TO BE REMOVED ;;) I o 1 :'�� 'r t; y.:;`•: i.= •°'�''.>'' �.�>:'`: -104. �, L ° ♦ W-101 - :r. '_ : ;.; a , .n i I y DE --------------------- / Project: ILL ' - EXISTING NG PORCH ___ . V A'S RESIDENCE 105 - '/ PLANTING AREA ALTERATIONS GENERAL NOTE: -REMOVE EXISTING WOOD 15 SUN LANE ,A e,, CEILING AND INSULATION : _ ,,° / ' �P. °,�', ,° /. Southold, NY 11971 ALL DOOR AND WINDOWS � �° �``�i �`` �� .'`/% ' �O r �� - REMOVE EXISTING TO BE REMOVED & A V I� 004 : ' 's `r' � %�� '%' ,j-' ��o /' �' SHEETROCK WOOD PANEL REPLACED.•;`. . // / i% i,/ / �.:'`` l Tine: 'r �"� WALLS DEMOLISH & EXISTING R11 EXISTING EXISTING CONDITION & f /� . . INSULATION FROM WALLS. NON-COMPLIANT /;y,% // DEMOLITION PLAN PORCH STRUCTURE / 71 Front PLANTING AREA Yard " L• 001 — s \ WOR C� DATE: 03/11/19 Demolition Floor Plan F N < P ,_ " W;, AWN BY: tC K BY: FV D No: 030814 �O`G` A-100.00 �--_—� CADb FILE No: of