Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
44140-Z
Town of Southold 1/15/2020 P.O.Box 1179 o _ 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 41000 Date: 1/15/2020 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2730 Grand Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 107.-2-8 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/27/2019 pursuant to which Building Permit No. 44140 dated 9/9/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof-mounted solar panels on an existing single-family dwelling as applied for. The certificate is issued to Sailor,Wayne of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 44140 11/18/2019 PLUMBERS CERTIFICATION DATED Aut ri e Si ature I TOWN OF SOUTHOLD o�svFFnc,roo .a ,"V BUILDING DEPARTMENT y x TOWN CLERK'S OFFICE Owl_ • o� SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) I' Permit#: 44140 Date: 9/9/2019 Permission is, hereby granted to: Sailor, Wayne PO BOX 317 Mattituck, NY 11952 To: install roof-mounted solar panels as applied for. At premises located at: 2730 Grand Ave, Mattituck SCTM # 473889 Sec/Block/Lot# 107.-2-8 Pursuant to application dated 8/27/2019 and approved by the Building Inspector. To expire on . 3/10/2021. Fees: SOLAR PANELS $50.00 i CO -ALTERATION TO DWELLING $50.00 ELECTRIC $100.00 1: $200.00 I Building I spector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy -New dwelling$50.00, Additions to dwelling$50.00, Alterations to dwelling$50.00, Swimming pool $50.00, Accessory building$50.00,Additions to accessory building$50.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy - $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy -Residential $15.00, Commercial $15.00 Date. ejj:�Vct New Construction: Old or Pre-existing Building: (check one) Location of Property: 2730 Grand Ave Mattituck House No. Street Hamlet Owner or Owners of Property: Wayne Sailor Suffolk County Tax Map No 1000, Section 107 Block 2 Lot 8 Subdivision %� Filed Map. Lot: Permit No. LHlqV Date of Permit. Applicant: Scott Maskin, SUNation Solar Systems Health Dept: Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ i • A icant Signatur so Town Hall Annex ~ ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 sean.devlin(W-town.southold.n us Southold,NY 11971-0959 y' BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To Wayne Sailor Address: 2730 Grand Ave city Mattituck st: NY zip: 11952 Budding Permit#. 44140 Section 107 Block: 2 Lot: 8 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor. DBA- SUNation Solar Systems Inc. License No: 33412-ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency FixturesTime Clocks Disconnect Switches Twist Lock Exit Fixtures Combo SD/CO Other Equipment 29- Photo Voltaic Roof Mounted LG370QlC-V5 Modules, 29- IQ7PIus Inverters, Enphase IQ Combiner 3, AC Disconnect Notes Photo Voltaic Solar Panel System Inspector Signature: Date: November 18, 2019 S.Devlin-Cert Electrical Compliance Form As Subdivision Filed Map No. Lot 8 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction. a. Existing use and occupancy Residence b. Intended use and occupancy Residence with addition of Solar Panels 3. Nature of work(check which applicable):New Building Addition__JAlteration__[� Repair Removal Demolition Other Workseiaraanais (Description) 4. Estimated Cost $28,258.00 Fee $200 00 (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If;garage, number of cars 6. if business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law,ordinance or regulation?YES_NO X 13. Will lot be re-graded?YES_NO X Will excess till be removed from premises?YES_NO X 14.Names of Owner of premises Wayne Sailor Address 2730 Grand Ave,Mattituck NY 11952 Phone No. 631-300-8745 Name of Architect William c F Sher Address 5095ayWJe 0wd.3ayvl11e,NY„702 Phone No 531-7854419 Name of Contractor SUNation Solar Systems,Inc Address 171 Remington Boulevard Ronkonkoma NYPhone No. 531-750-9454 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO X *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland?*YES NO X *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17 If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO X *1F YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk Scott Maskln-President-SUNatlon Solar Systems,Inc being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief,and that the work will be performed in the manner set forth in the application filed therewith. Swam tglbefore me thi day o 20�_ Notary Public Signatwe o scant VICTORIA M. WALKER NOTARY PUBLIC-STATE OF NEW YORK No olWA6319756 Qualified in Suffolk County My COmmIS5lon Expires February 23, �aOE SOUtHpI 4 I 2 ` 5O ar444e f # TOWN OF SOUTHOLD BUILDING DEPT. cou765-1802 INSPECTION - [ _ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [. ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL)`, [ ] CODE VIOLATION ] PRE C/O REMARKS: IMAM, fr"IlExZ�2M Ate /AI M564--104-) - alb DATE Al IlAll INSPECTOR Graham Associates , 1981 Union Blvd. Bay Shore,N.Y. 11706 Building Consultants & Expeditors (631)665-9619 Fax(631)969-0115 October 25, 2019 Town of South Building Department _ 1 � Re: Permit# 44140 JAN 2020 Sailor Residence 2730 Grand Avenue, Mattituck Installation Inspection Date: 10-24-2019 To Whom It May Concern, The roof mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the approved plans and is certified by Graham Associates to be in compliance with the minimum requirements of the Town, the 2015-International Residential Code and the 2017-New York State Uniform Code Supplement and the Provisions of ASCE 7-10. If you have any further questions, do not hesitate to call. Sincerely, y�� ED A,q? � � 4 Michael K Dunn, - FIELD INSPECTION REPORT DATE COMMENTS 4:-�d E FOUNDATION(1ST) � y ------------------------------------ Do FOUNDATION (2ND) z o W � ® y ROUGH FRAMING& PLUMBING H 1 r INSULATION PER N.Y. H STATE ENERGY CODE _ FINAL ADDITIONAL COMMENTS ot��� Q m X 0 -- z H x d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying9 TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Pla is_ '`�w "!71'-''Iµ TEL: (631)765-1802 Planning Board app- v FAX: (631)765-9502Survey } SoutholdTown.NorthFork.net PERMIT NO. Check 1 Septic Form — AUG IG 2 7 2019 N.Y.S D.E.C. Trustees C.O.Application Flood Permit !, '? Fri,7 Examined 20_ Single&Separate -• I Storm-Water Assessment Form Contact: Approved 20 Mail to-SUNation Solar systems,Inc Disapproved a/c 171 Remington Boulevard,Ronkonkoma NY 11779 _ II Phone:(631)750-9454 Ftzpirahon V i — 20 Buildi g I ector AUG 2 7 2019 ,APPLIC N FOR [LDING PERMIT r 41?y � P tJ INSTRUCTIONS J XAf% a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adorning premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. Signature of applicant or e,rf a corporation) SUNation Solar Systems,Inc 171 Remington Boulevard,Ronkonkoma NY 11779 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder SUNation Solar Systems,Inc-Contractor Name of owner of premises Wayne Sailor (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer Scott Maskin-President (Name and title of corporate officer) Builders License No.44104-H Plumbers License No. NIA Electricians License No,33412-ME Other Trade's License No. 1. Location of land on which proposed work will be done- 2730 Grand Avenue Mattruck House Number Street Hamlet County Tax Map No. 1000 Section 107 Block 2 Lot 8 ur SO�lyo Town Hall Annex JxR ( Telephone(631)765-1802 54375 Main Road �G sP.O.Box 1179 rogendchert. own oago2 ny us Southold,NY 11971-0959 y�OUNi'I,�� BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: Company Name: SUNation Solar Systems, Inc. Name: Scott Maskin License No.: 33412-ME Address: 171 Remington Blvd, Ronkonkoma, NY 11779 Phone No.: 631-750-9454 JOBSITE INFORMATION: (*Indicates required information) *Name: Wayne Sailor *Address: 2730 Grand Ave Mattituck NY 11952 *Cross Street: ' *Phone No.: 631-300-8745 Permit No.: L4 t 4a Tax-Map District: 1000 ection: 107 Block: 2 Lot: g *BRIEF DESCRIPTION OF WORK(Please Print Clearly) Installation of solar panels,- flat on roof (Please Circle All That Apply) *Is job ready for inspection: YES/� Rough In Final *Do-you need a Temp Certificate: YES t _O) ' - Temp Information (if.needed) *Service Size: 1 Phase 3Phase 100 150 200. 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service 'Overhead Additional Information: PAYMENT D_UE WITH APPLICATION 7� /00 X82-Request for Inspection Form Scott A. Russell ,��°Su `�00, ST 1R.MWA\T]E]k suPERvis®R - MANAGEMENT SOUTHOLD TOWN HALL-P.O.Box 1179 0 53095 Main Road-SOUTHOLD,NEW YORK 11971 Town of Southold CHAPTER 236 ® STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT INVOLVE ANY OF TlE-3[lE ]FOL1,0WIING: Yes No (CHECK ALL THAT APPLY) ❑ A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑� C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑� D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑d E. Site preparation within the one-hundred-year f loodplain as depicted on FIRM Map of any watercourse. ❑� F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT (Property Owner,Design Professional,Agent,Contractor,Other) S.C.T.M. #: 1000 Date District NAME. Scott Maskin Section Lot C,� �, ****FOR BUILDING DEPARTMENT USE ONLY**** Contact Information �o ✓I — ` l y ✓y trelephorc Number) Reviewed By: — — — — — — — — — — — — — — — — Date: Property Address / Location of Construction Work: — — — — — — — — — — — — — — — — — 2730 Grand Avenue ❑ Approved for processing Building Permit. Stormwater Management Control Plan Not Required. Mattituck, NY 11952 ® - - — — — — — — — — — — — — — Stormwater Management Control Plan is Required (Forward to Engineering Department for Review.) FORM * SMCP-TOS MAY 2014 Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) I, Wayne Sailor residing at 2730 Grand Ave, Mattituck (Print property owner's name) (Mailing Address) do hereby authorize Scott Maskin (Agent) to apply on my behalf to the Southold Building Department. (Owner's Signature) (Date) (Print Owner's Name) oF sovey®l Town Hall Annex ~ O Telephone(631)765-1802 54375 Main Road 411 Fax(631)765-9502 `P.O.Box 1179 Southold,NY 11971-0959 y� lyCOU0,� BUILDING DEPARTMENT TOWN OF SOUTHOLD December 16, 2019 SuNation Solar Systems 171 Remington Blvd Ronkonkoma NY 11779 Re: Sailor, 2730 Grand Ave, Mattituck TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: Note: Engineer's Post Installation Certification letter still needed. C Electrical Underwriters Certificate A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT —44140 — Solar Panels Graham Associates 1981 Union Blvd. Bay Shore,N.Y. 11706 Building Consultants & Expeditors (631)665-9619 Fax(631)969-0115 August 26, 2019 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: Sailor Residence 2730 Grand Ave Mattituck, NY 10.7 KW Rooftop Solar Photovoltaic System To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 130 mph wind load without overstress, in accordance with the following: 2015 International Residential Code (2015 IRC, 2ND PRINTING) + 2017 New York State Uniform Code Supplement (2017 NYSUCS); Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2014 National Electric Code NFPA 70/2014 National Electric Code including ASCE?-10 Ifryou have any further questions, do not hesitate to call. ,X�`�� RA �A.4 029 .0 ®F New York State Insurance Fund Workers'Compensation&Disability Benefits Specialists Since 1914 199 CHURCH STREET,NEW YORK,N.Y. 10007-1100 CERTIFICATE OF WORKERS' COMPENSATION INSURANCE A A A A A 753118816 f = SUNATION ROOFING SERVICES INC 171 REMINGTON BOULEVARD ' RONKONKOMA NY 11779 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z2160 670-2 482687 01/01/2019 TO 01/01/2020 3/12/2019 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, ,AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS:/MIWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY. NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:453899859 Show Receipt Detail Page 1 of 2 RECEIPT Suffolk County Government SUFFOLK COUNTY LABOR, LICENSING & CONSUMER AFFAIRS P.O. BOX 6100 HAUPPAUGE, NY 11788 James M. Andrews Application:ME-33412 Application Type:ConsumerAffairs/Licenses/Master Electrician/NA Address: Owner Name:SUNATION SOLAR SYSTEMS INC Owner Address:171 REMINGTON BLVD RONKONKOMA,NY 11779 Application Name: Receipt No. 160594 Payment Method Ref Number Amount Paid Payment Date Cashier ID Received Comments Check 27486 $400.00 06/04/2019 CLEMON RENEWAL Owner Info.: SUNATION SOLAR SYSTEMS INC 171 REMINGTON BLVD RONKONKOMA, NY 11779 Work Description: y, Suffolk County Dept.of Labor,Licensing&Consumer Affairs u MASTER ELECTRICAL LICENSE Name i SCOTT A MASKIN Business Name This certifies that the SLINATION SOLAR SYSTEMS INC bearer is duly licensed I by the County of suffolk License Number:ME-33412 Frawk.Nati-dz" Issued: 06/24/2003 Commissioner Expires: 06/01/2021 ' 1,ttnc•//axinrnr1 -,nffnikrnt,ntvnv vnv/nnrtletS/fee/receintView.do?mode=view&autoPrint=fals... 6/4/2019 SUFFOLK COUNTY DEPT OF LABOR, LICENSING&CONSUMER AFFAIRS HOMEIMPROVEMENT CONTRACTOR LICENSE SCOTT MASKIN This certifies that the 13umcs NA"e bearer Is duly SUNATION SOLAR SYSTEMS INC licensed by the Lkam.N—b r 1 0-11—e County of Suffolk PAI.Iz om. ll: 44104-H 03/06/2008 eemrirs6".' EOR41ION DATE 0301/2020 :f> I LG370Ql C=VS 370W LG Neon R Is LG's highest efficiency module In the market and provides world-class performance.The unique,back-contact cell structure eliminates electrodes on the front which maximizes the collection of light and Improves overall reliability LG Neon R features an enhanced warranty, - �•• , Improved aesthetics on residential roof-tops,and the highest performance ♦-♦_� and durability under real-world conditions ♦ • • 111� w�ovm mooucr coos cc - Features Aesthetic Roof Extended Product Warranty LG NeON®R has been designed with LG has extended the product warranty aesthetics in mind the lack of any of the NeON®R to 25 years,which Is top electrodes on the front creates an level in the industry improved,modern aesthetic Better Performance on a Sunny Day More generation per square meter LG NeON®R now performs better on The LG NeON°R has been designed to sunny days,thanks to its Improved significantly enhance Its output,making temperature coefficient. it efficient even In limited space About LG Electronics LG Electronics is a giobat leader in electror¢products in the clean energy markets by offering solar PV panes and energy storage systems The company first embarked on a solar energy source research program in 1995,supported by LG Group's vast experience in the semi-conductor,LCD,ctemistry and materials industries In 2010,LG Soar successfully released its first fdonoX`e series to the market,which is now available in 32 countries The NeON@(previous MonoXG NeON),NeONe2,NeONO2 Bihacial won the',ntersolar LG Solar AWARD"in 2013,2015 and 2016,which demonstrates LCs'eade,ship and innovation in the solar industry r Ir LG NeON'R LG370QlC-V5 General Data Electrical Properties(STC*) Cell Properties(MateriaVType) Monocrystalline/N-type Model LG370QIC-VS CeOMaker LG Maximum Power(Pmax) [W)I 370 CellConfrguration - 60 Cells(6 x 10) MPP Voltage(Vmpp) __ TT [V] 370 —'Module Dimensi0ns(UW.x H) 1,700mm x 1,016mm x 40mm MPP Current(Impp) [A) 1001 Weight. 17 5 kg open Circuit Voltage(Voc,*5%) [VJ 428 Glass(Thickness/Material) 2 8mm/Tempered Glass with AR Coating shor'tGrcuit Current(Isc tS%) [A] 1082 Backsheet(Color) - - White - ModuleEFBciencq 21 4 Frame(Material) Anodized Aluminium PowerToleranre 0-+3TJ Junction Box(ProtetGon oegree) IP68 with 3 Bypass Diodes •STC(Standard Test Condition)Irradiance 1000 Win",Cell temperature 25°C,AM 15 Cables(Length), 1,000mm x 2EA Connector(Type,/Maker) MC 4/MC Operating Conditions Operatmg•remperature [°CJ -40-+90 Certifications and Warranty Maximum System Voltage [vJ 1,000 IEC 61215-1/-1-1/2 2016,IEC 61730-1/2 2016, Maximum series Fuse Rating [A) 20 —� UL 1703 MechanicatTesttoad"(Front) .. (Palpsf) 5,400/113 Certifications ISO 9001,ISO 14001,ISO 50001 MechanicalTest Load(Rear) [Palpsf) 4,000/835 DHSAS 18001 *Test Load-Design x Safety Factor(1 5) Salt Mist Corrosion Test IEC 61701 2012 Seventy 6 Ammonia CorrosionTest IEC 62716 2013__ _ Packaging Configuration Modula Fire PerformanceType NumberafModules perPallet [£A) 25 Fire Rating Class C(UL 790) Number ofModutesper 40ftHQ Container' [EA) 650 Product Warranty -25 Years ,Packaging Box Dimenskms(LxWxH) [mm) 1,750 x 1,120 x 1,221 Output Warranty ofPmax _ - Linear Warranty* - � Packaging Box Gross Weight — m..[kg) 473 *1)1styear 98%, 2)After lstyear 03%annual degradation, 3)25 years 908% Dimensions(mm/Inch) Temperature Characteristics NMOT* [°C) 44 t 3 Pmax __. L%/'Cl — --0.30 1016 0/40 0 Voc [%/°C) -024 576.0/38.4 Ise [95l°C) 0037 Gro n Holes 175. 175.0/c'.5 40 0/I 57' NMOT(Nominal Module Operating Temperature)Irrddlance 800 W/m2,Ambient temperature 20°C, R A4.iIn. Groundin— Hol- Wind Holes Wind speed 1 m/s,Spectrum AM 15 \ Mounting Electrical Properties(NMOT) Model I LG370QiC-VS Maximum Power(Pmax) CW)i 279 _ MPPVoltage(Vmpp) M 369 vy m my MPPCorrent(Iriipp) [A) -- 755 OpenCircurtVottage(Voc)- [V) 403 0 11. t g shortCircuitCurrerrt(Isc) [AJ 871 �u" o` 01 ob or or 0. co. o. IN Curves - - 12 t000w 1C eoow y ...,...,......,..-.... ,. 6WYP r E 0 0 0 U 40 m 0w N 2 200W,—__ 0.0 100 200 300 400 I Voliage M 'I LG Electronics Inc i Product spenfications are subject to change without notice Solar Business Division I LG370QIC-V5_US_Ver0I pdf LG 2000 Millbrook Drive Lincolnshire,IL 60069 L[fe°s Good wwwlg-solarcom ©2019 LG Electronics All rights reserved r� ` E n� ase NQ System uomponem LiSt S7[yiffitll ` |Q7'60'2-US |Q7PLUS'72'3'US IQ7X-96'2'US Enphaue|Q7yNinnoT* 25OVApeak power, Enphaae|Q 7+&8ionoTu205VApeak power, Enphame|Q7XNlicroTu32OVApeak power, K4C4DCconnectors,female ACconnector MC4DCconnectors,female ACconnector K4C4DCconnectors,female ACconnector Compatible with bO-oe||PVmodules Compatible with 60'and 72'oe||PYmodules Compatible with 0h'ce||IDV modules |Q6'60'2'US/|Q6PLU3'72'2'US ENV-|Q'AM1'240NY Enphuoe|Q 6 MicroT1,1,compat/b|evvith60'ceU EnphaoeVQEnxoyTw.single- PV modu|es,240VApeakpnwer, phase,metered Revenue-grade Enphaue|D6+NY|cmr .compat/b|ewith00' accuracy(ANSI Cl220+�U5vQ and 72'oe||PVmodules,2gOVApeak power with calibrated solid-core CT -- Compau/b|ew/th|Q�/cmoon|y K4C4DCoonne�or�female ACuonne�oc Accessories for IQ Combiner 3 1 BRK-1 OA-2-240 Circuit breaker,I j, BRK-15A-2-240 Circuit breaker, 2 pole,15A,Eaton BR215 BRK-20A-2P-240 Circuit X-IQ'AK81'240'2N} breaker,2 pole,20A,Eaton BR220 ENV-|Q-AK83'3P Enphase IQ Combiner+lm with Enphase IQ Combiner 3TM With IQ EnphaaeUQCommercial Enxoy1w. |QEnvoy,8OA,a/ng|e'phuoe. three-phase,metered rexenue'gmdepmduotmn recetacle for Power Line Carrier Revenue-grade accuracy(ANSI metering Compatible with metering Optional C122O+/-O5%)with split-core OT Enphaue|QMicros and|OBatteryXA-ENV-PCBA-3 IQ Compatible with|QMicros only Optional consumption monitoring Single-stud mounting PCB For replacement only � ~W- -W ` CT-200-SPLIT OELLMQQEM'01/'03 EPLC-01 Q-BA-3-1P-60 EnphaoeConsumption CT, EnphuoeMobile Coonectuand EnphauePower Line Carrier EnphaneAAggregator, split-core current transformer, Mobile Connect+mcellular Quantity combines uptothree accuracy+/'2.5%for monitoring modem with 5'and l2'year m/cm/nverterbranches,b0A who|e'homeenepgy data plans(US.Canada,Puerto Rico, max,includes one U'8A,CAP consumption Compatible with Mexico,USVirgin Islands) Compatible with 0Cable |UEnvoy and|OCombiner For systems with up1oO0micros ������K� � ���� ��o�� no w���o� N-0 ® •"'� t `re .4, �.`�ia� .y.av .,,..p•. �"a�:•e"r._ .'`:,'•e•�" _tl IQ6PLUS-B1200-LL-1-US00-RV1 BWM-161N-B Enphase IQ BatteryTV with integrated Enphase Battery Wall Mount BracketT+°' IQ6+Micro,280W/1 2 kWh,240 VAC '"" , $ Size 487 mm(W)x 356 mm(H)/19 2 1 split-phase,indoor-residential, In (W)x 14 0 in (H),accommodates -_ •_ lune-to-line communications 16 in battery-to-battery spacing Compatible with grid-tied PV systems Compatible with Enphase IQ Battery using the Enphase IQ Envoy Q-12-10-240 Q-12-17-240 Q-12-20-200 Q-12-RAW-300 Enphase Q Cable"'-1 for 60/72 Q Cable m for 60 cell 1 7m Q Cable TM for 72 cell 2 Om RAW Q Cable m is one(1)spool cell 1 Om portrait module pitch landscape module pitch landscape module pitch at 300m/984 ft length 12 Connector pitch Is 1 3m 240 Connector pitch Is 2 Om 240 Connector pitch Is 2 3m 200 AWG,no connectors Included male connectors plus two(2) reale connectors plus two(2) male connectors plus two(2) bonus fink connectors bonus link connectors bonus link connectors Q-TERM-10 Q-SEAL-10 Q-BA-CAp-10 EFM-35MM/EFM-40M Enphase Q Cable Terminator Enphase Q Sealing Caps, Enphase Branch Aggregator Enphase Frame Mount for Cap for Q Cable ends Center female sealing cap for unused Q Cap,male sealing cap for mounting Enphase feed requires two(2)per Cable connectors Pack of 10 unused Q Aggregator Mlcrolnverters to 35 mm or branch. Pack of 10 connections 40 mm module frames Q-CLIP-100 Q-DISC-10 Q-DCC-2 Q-DCC-5 Enphase Q Cable Rail Mount Enphase Q Cable Disconnect tool Enphase IQ Replacement Enphase IQ Replacement Cable Management Clip Pack for Q Cable connectors,MC and Adaptor for MC4 DC Adaptor for UTX DC of 100 Amphenol DC connectors,and AC connector (Amphenol)connector module mount Pack of 10 Q-CONN-10M Q-CONN-10F Enphase Male Field-Wireable Connector to Enphase Female Field-Wireable Connector make connections from any Q Aggregator to make connections from any Q Cable open connector Requires MC4 crimp 9 open connector Requires MC4 crimp tool PV-CZM-18100,-19100,or-22100 for tool PV-CZM-18100,-19100,or-22100 for connections to Q Cable or RAW Q Cable connections to Q Cable or RAW Q Cable For more Information visit WWW.enphase.com or call (877)797-4743 ENPHASE., ©2018 Enphase Energy All rights reserved 9-10-18 4 S E R.1 ® • The SnapNrack line of solar mountingfq '•.� � ry� Z systems is designed to reduce total M `w`3% b •'fix y+. ��e �u %�k?�.L..•� installation costs. The system features > �r' •'M ;k Vis} �•�'"Y °• e � :�' technical innovations proven on more than 20OMW of solar projects to simplify installation and reduce costs. Flashed L Foot Simplified ' „ SnapNrack Series 100 Flashed L Foot Kit is an innovative _ solution to provide a long lasting watertight seal over the life of the system. The Flashed L Foot provides a q single fastener flashed to an attachment composition Flashed L Foot in 3 Simple Steps: shingle roof with no required cutting of shingles. The L 1) Locate the rafter and drill the pilot hole Foot is engineered for maximum adjustability for a clean level installation. 2) Prep and attach the base S) Set the flashing and attach the L Foot • 1" slotted bolt connection • 1"spacers available for increased adjustability • Clear or Black anodized aluminum components Place order through your SnapNrack (both available with black flashing) distributor, which can be found at www.snapnrack.com/cohtact • No Cutting of shingles rack Sna Patent Pending . I 1 I III Will, is I Will I I '1 11 --Ill. I I Flashed L Foot Kit Assembled(1'spacer sold separately) Flashed L Foot Kit Parts(1'spacer sold separtely) Flashed L Foot Kit Assembly Flashed L Foot Kit Dimensions SNAPNRACK CHANNEL NUT SNAPNRACK 92 DEGREE L-FOOT,CLEAR 5/16-18 FLANGE NUT SPLIT 1 X 111N BOLT WITH `�^ SPLIT LOCK HER SNAPNRACK COMPOSTRON FLASHING .x s. ,y o \ 39� `SNAPNRACK L-FOOT BASE 88 thapWack Flasheid L Poot Tethnical Data Patent Pending Materials 6000 Series Aluminum L Foot&Base Stainless Steel Hardware Galvanized Steel Flashing Material Finish Clear and black anodized aluminum Weight 016 lbs Design Uplight Load 200 lbs Uplift Design Ultimate Load 1,000 lbs Uplift Warranty 10 Year material and worksmanship Sin a rack (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks ©2013 by SnapNrack PV Mounting System All rights reserved S ERIES .100 UL--, .................. IiL ................ ...................................ll E.................. ............ The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive . down costs and improve installation quality on more than 3S0 MW of solar installations. Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System p Y is an efficient,visually appealing, photovoltaic (PV) module installation system. Series 100 UL is Listed to the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for goof System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1)Go to the online Series 100 Configuration grounding hardware.The System's components provide Tool (configure.snapnrack.com)and select an adequate bonding path which has eliminated the "Yes" for UL 2703 Listed need for grounding lugs and washers at each module, and bonding dumpers between splices The UL 2703 2) Identify Site Conditions(Array Tilt, Building Listing ensures that SnapNrack partners can provide Height, Roof Type, Wind and Snow Loads) the best in class installations in quality, safety, and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of Materials. • All bonding hardware is fully integrated into the components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail dumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules VL LISTED PV Mounting System Patent Pending 2703 Stainless Bolt with — Stainless Steel SnapNrack Bonding SnapNrack Standard Rad Bolt with Split- ! Splice Insert Split-Lock Washer Lock Washer SnapNrack Bonding F SnapNrack °I Adjustable End SnapNrack Splice Clamp Top ;•� Bonding Base �.,� Mid Clamp SnapNrack SnapNrack Bonding SnapNrack Adjustable End - SnapNrack / Stainless Channel Nut Clamp Bottom Bonding -Stainless Hardware with Bolt with Channel Nut Split-Lock Washers Split Lock SnapNrack Bonding SnapNrack Bonding Washer P 9 SnapNrack Bonding Adjustable End Clamp / Mid Clamp Standard Rail Splice SnapNrack --- I Ground Lug 10-6 AWG- Copper Wire SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) - SnapNrack Bonding Universal End Clamp(UEC)Wave UEC Pull Strap — UEC Wedge L Stainless Steel Bolt with Flat Washer _ SnapNrack Bonding Universal End Clamp SnapNrack �s;i►' Bonding Standoff Clamp Assembly SnapNrack Serrated Stainless SnapNrack SnapNrack Bonding Rubber Steel Flange Nut Bonding Channel Nut Channel Stainless Rain Collar Serrated Stainless Nut Flange Nut Steel Flange BoltSnapNrack + - Stainless SnapNrack d Flan Mill Finish 92 Degree 9e Standoff L Foot Bolt SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff L Base(1-Hole ow / SnapNrack MetalRoofBase Shown) / SnapNrack L Foot Mill Finish 4' Flashing Base Assembly L Foot Base IL- SnapNrack Metal SnapNrack Bonding SnapNrack Bonding Roof Base with Standoff Assembly L Foot Base with Flashing Bonding L Foot I SnapNrack • • UL Technical Data Patent Pending Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum • Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with Integrated bonding features Calcs. &Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type 1 and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug (One Lug per individual row of modules) Warranty • 10 Year material and worksmanship (download full details at snapnrack.com) Scup ? rack- - (877) 732-2860 www.SnapNrack.com A Printed on recycled paper using soy based inks ©2015 by SnapNrack PV Mounting System All rights reserved � =Ad a3NI36 A cow Nmol 3HI dO VINMII :)N91930 3HI 15 665 SNVId VN VMC3 51 Ol „0-,£ 3a3n3S Vb v L 7 SELL 6 0£1 dSd BZ ZIOd S1N3W3ZlIn(93ZI 3400 31V1S�IZIOA n13N 4330X3 339 °ou L10I Son 31VIG =to s f113N cNV NO 13314 aNVM(ONVH(3NV 913�10Va9 0NI1NnOW 03LIn03a 3N= 810E 0ZlI'0l-L 30SV 3Hl 30 S3?Jn10nZ11S ZI3H10 .11431 X30NI ONvzvm 1N3W-x V•la3°Nfl .14131 H1d3O Aa0%31Vo 621930 Aa0V3iVV N0103a S173�33 (I-WW) OVOI MONS NVId 3116 31111 cNV VM( nn9 ZIOd SMIMCNVIS NVIS3a WnWINIW IVnNNV VNR33ad NVIS30 311Wa31 3Nn VNNSH1VSM 31BNOZ10 NVIS30 3NaO0 3ansodX3 °NM OIHdVa�JOdol 033.19 ONnONO SNVdG N314VN- !5'ZOBZI 319V1 5102-0ZII NV9W aro COO-1:1 a31a i a31NIM 19Oad Ow913s IV03ds 3HI 13314 Ol c3N�IS3c N339 SVH W319AS nd slHl () 301 °N1m aN1m 'S'.L'N 01 WaIOdNO0 SNOISN3WI(3$s3Z16 a314VZI ONIISP(3 3HI -6V3H9 s 14ndn IDNIamONI W310.L9 3lncOW 30VWVc Ol 103r9nS NVI93c cNIM 01VI1OAOlOHd 3HI A9 c39OdWl SCVOI f113N 3H1 WIN WIN XXXXXX NOI103dSNl(3NV IIWN3d 47NI9Wfnd V 93a1n1,3Z1 1ZIOddnS Ol 31vnD3cV SI azin10nNis ONIISPC3 3H1 (I)Z'I®Pc�1 3�9b'1 - b`I?1311�7 N�IS�CI �INdb'��03� 711'D'WI,� V/N WIN XXXXXX 1N3n 3HI d0 NOI1V01dICOW ZIO NOI1V00IMN kNV N1N3W31V1S IV�Jn10n+J1S OIIVMV'ISNI LNBWcllnDM NVI09 Z0:f c0 3NMAO WIN WIN >CKXXXX ZJO ln0 39 OI ION 3ZIV GIN3A VNI9Wnld-LNV' S d6d-5 NVHI SZIOW(333OX3 WIN S1N34H7V1V IVIO3d6 WIN WIN xX'�o(�ot 33SN30n 3H1 40.L1n191SNOdG3Zl 3Nl SI 3aVdl3nl cggQybu Iy®4933cISRgg lWgdM3M aolVlm-roO N0110naoa8 NOLLVNn9 30anos NOLLOnaoad 163 ION-nVH9 W31SJL9 c3MVIISNI 3HI d0 1HV13n1 4 0n9nd(3NV LINS.IONcl'Hl'IVSH '3dn d0 310N a3N9193G 31V0 aA/Hm*A 806'6 O'o7 N0117nO0ad 153 dcoZi ONlcavnv34V9 3H1 01 M31A HIlM cNV 30110VNd MA L01 O0)ONUVal W31SAS No1s1n3a 3HI d0 30Vdwe 3HI 3n09V 99H0NI-9 NVHI 30 SCZIVCNVIO 3I9VNOSVMN HIlM 9WZI0dN00 • OavONV1S 3v"V Vd e3lvaow NosAvr 3ZIOW ON cNV 01 I3TIVNVd'c31NnOW-H9m:i NOIGSIW9n0 3HI d0 3WI1 3HI 1V XVW „E-,4 3Sn„X„91109 1334 VNI1NnOW NSSMIS9 NVd9 WnWPCVW T"valln-�1OVa,N.dvNs VMAV a A9 Nmva° 39 llVH9 1N314d1n(93 NVIOS d0 NOIIV nV'ISNI 5 319V0nddV 93000 ONIN�3AOV Hlln)SWNOdN00 • „£-,4=91109 6b/Id llV'N„0-,01Z=133.1 IIVN lV'101 WIN a HONVae '1N3WdInD3 ZIVIO9 31VZ1n00V • 64=1109 OV•l/S9l Z£5/991 968'rsZ=c3ZIIn(93ZI s1109 0V'l 40 a39WnN WnWINIW (exDLo HON VNQ HONva9 3HI Ol NOI11ccV NI ONINSA00 BOON d0 Z13AVI :91 1N3Wn00c NI>ZI M 3HI NOlIV'WZI04Nl cNV 43n39 dVI HOV3 ' 0 '9lZ£5 (6Xpl n H69 3lONIS V NVHI 321014 ON 3AVH-nVHS dOOZI 'Z 9,33SN30n 3HI d0 1939 3HI O01. '1VH1 NOUV19311V (LIX1)I a =Hld3c cV3ZIHl HONI-L X NI/9l 99L''Vlc „91/8 9nIV/�lVfl1VZlcMllfll 1109 47V1 sn-cL-smdLcl(6z) a31a0ANI3nw oaOw NOI1VIIIN3A aVC31N?104 mo-nv,Ol 0Sn NV SV c313NcINMIN1 N339 SVH 3ZIn1VN91S cNV IVHS (S11O0 5v-OIVOL£9-I(6Z) 3ln0ow S.LN LIOZ(3NV VNI 810Z 3H1 HIlM 30NVcRA000V 1VH1 'cNO0 EIN d0 IVNOIG93dOad NVIS30 0391sl30n VVI HIlM men 39 Ol c3Zlln(93Z{SZI3HSVfi1 1Vld) •40/8'Z£0L 03.19 n13Z10S 0vl NI c3cUAOad 39-nVHS 9V3JV 90300V cNnONV 31VIS�IZIO.L n13N 3HI d0 aNnIVNOIS cNV-1V398102/90(49/#Z Z)mncOW/#r*L'01r cNV'S1NIOd 98300V:BOON'S.LVMH1Vd 99300V 3H1 ZI3cNn c331NVZIVn17 SI uni919NOds3ai 1VH1 J3N31SV4 zld 89'81 'c„9'I X M,,Ov X l„6'99 WIN I 1N31014dnG 'II NO 1N3WdIni93 NVIOS MAVH '3000 1VHl HIIM 30NVndWO0 331NVZIVnO ION S30c VS IiVM OLS slvla3lvw IVN01110av ION 930c IVHI 3VclZf 3HI d0 3019 a3H10NV n131n3a 91H1 -AW.L f113N d0 31V1S 3HI 40 30005V-0I(90L£l XONOW l3cOW V'1 NO T4O 1N3WdinD3 NVIOS 3HI 9V 3cIG 3WVS -MUN3cISSN ZIO/(3NV ONlclln9 3HI NI c3WI03dS S9l 968'SZ==is 4L9 X d9d 5'Ib=14ndn 1V 101 3HI NO 30c1a dOOZ<3HI d0 3c1S 3NO 1SV31 XVW d6d SV N11101 3H1 d0 Nw ag zl1n(9 a 1V111W9nS N0Id 1V ONO5 Ib(133HS SIHI'SNOI1Vlnowo 336)01 308V :cVOI CNIM 39 IIVHG(1N3Wdlnt93 319V1d300V WnWMIW aOd 1N3Wn00c c35010N3 JVIOS d0 33Nd)VNINV3l0 SC31M ,91 NV 'I 3HI c3A1303Z1 GVH NSNIWVX3 SNVId ONIclIn9 N(001 AS VZ9=VEINY AVNNV 1V101 93ION 31ON n13VA3a ONIclIn9 •91N3WMN nv3N NEIN31SVd ��®•S•�•pl GIN•31V09 9'1N .3lV�G Wn (c"I)N011039 dOoa SB OH1 NM0101000S NVIed 400ZI 3SnOH I5n4 Ilvm aola3ix3 NV'd9IVfI1OV 08V09 ONINNtl1d NM01010H1nOS VSZ NMOL 01®Hinos 0'O„91/„9 X„Z WIN 1 - 133x16 ONIOVd-39n0H=10 1NOad Z131dVZl .30 S N O UI Q N O J CI v” a 3��I.Jm n()3H SN 31V4 ss3OOv V/N:9311 ZIVll00 irs66 i mncOW COOMLld VNIHIV3HS a39WnN GIC - 01V1lOAOlOHd S ds „5'01-,£l'NVdS 1Vn10V Zs611 �I5nlIl1VW -= 3l�V ONVNV 0£LZ (g) 9 „5'01-v1 30c1?J 0'0„91/ „9 X„Z ONIOVdS/+J314VZI 3�N3cIS3Zl ZIOIiV6 L 'V +a1 s v ssa v oaw a3wols(IOLLAA A ^ n S 10�J83 N ondiSN 0 UO NOIS3a 3�n1011�15 � d00� 96377V ma vq d I41m �1pd 3181SNOdS� 1 N '31d1S MHOA N,�v iJJU �u a3llVISNI AVOMAlaa N3GWnNmoa M N d0 S3000 3Hi 0 S1N3V'�3�Im3c, Vaa3SAN (191) s3inaow nd (e) - 3H1 133N �1bHs NOI.�onHlsNoo ��d 3.�,������� �� ��� ������� 6LLI1 AN VW0'AN0 I40aAAkA 00 i]Od 3131d1N00 38 f n Onl9 N01�7NILJ3L1 ILI u , 6WCAIGNOIVN NOIlVNf16 ism N0110nHiSN00 _ ldNld 'ti i�� � � r � —;��' „81-NOIIVIIIN3/� NOILdInSNI 's t � k rI I"'�����J 09 Vino4,11•e,elo5 \ Ijj UOI��N�S --tf) -„61-NOIIVILLNMA -NOUV00l 3VVNV� JNI�7Vdnld R JNINVHJ - Honou 'z �; �� �3 NOUVOOl 1N3W39V9 vvvvvv vv _NOI1VVOl NOOl4 101 03�Jin031i OlVll - NOIltfONnOd r�OtoNd I-� -NOIIVOOI NOIZ131X3 :SN01103dSNl ONIN'tGl-IOd �Il'v'W3HVS �7NI139'vi �4 0� N3VNVHO As Ne -ZI011NOW 3SN39 3Hl Ki `/Id 1? GZ �I`�8 ZO$('S9L W'O WDIQ l-3 A NOIlO3NNOO 3c1s xi wrney 1N31J'11'i�{,i �'� Jr11011no1 ' lON 3Nn 3N0�V�I�1�3�3 vvvvvvvvvvv dooa '-'3d wvNvv'IQ iI Nio 3S'vhidN3 £-V 9 ;S3inaOW Rd 10/�OlOHd(IZ) ® -103NN00SIc .1 `' �L w ( 01V1l3NVd �A NVId 993!DVt> 400N Z-V ##,d•S 3 Lv® 1110ILVI_1VIIINV'd I-VI ® -3d1d 1N3A �`°• �� �C -3NVd 901AN3S NIVW ”' NV-Id 3119 I-Ned 9s3OOvJL3�I N did ONnoao as - 103NN00SIc 301AZI3S -a313W Alnlln a ��liAE c5 (1) BOH EAST ROOF �A lro° TRUE; 21" TILT; 5/12 PITCH ' 0 ?817 (21) MODULES GUTTER lZiat 0 43'-10" �/ 8 A7 A6 A5 X SUNation sa....it mowe be / SUNATION SOLAR SYSTEMS f Ill REMINGTON BLVD RONKONKOMA KY II119 ALNSTALLE 4355 INSTALLER NUMBER 14'-10y' CUSTOMER INFO SAILOR RESIDENCE DRYER VEI IT 2-130 GRAND AVE \*"; "X 6"14 "TA SNAP'N'RACK SYSTEM MATTITUCK 11952 A A,1A A A (TYPICAL RAIL ACROSS JOB NUMBER EACH ROW OF ARRAY) A Al (ONLY TWO SHOWN FOR I C3 CLARITY) DATE 5.6.1 PHOTOVOLTAIC 3e'xai' JOB NOTES MODULE(TYP) T6'iALL RIDGE I NIA (2) FOH WEST ROOF 2560 TRUE; 21" TILT; 5/12 PITCH (8) MODULES }SPACING BETWEEN ROWS �/ 12 ADDITIONAL MATERIALS f� I NIA Vvvf VENT tjIPE / C / j f 13-I" ,• SHADE 14'-1 e" DRAWN BY / f r RASHID SAMAR 13 ROOF AREA / vvvv ^/ DATE DESIGNER NOTE/ cuiET V / 822111 JM FINAL ,&'TALL X 45 >«.>«. NIA N/A PARTIAL HOUSE ROOF PLAN N/A N/A SCALE' 3/16" = 1'0" �«-- NIA NIA SCALE GUTTER I TITLE'PARTIAL LAYOUT APPROVED BY: A- 1 GROUND FENCE FENCE ,sjT .Fd '"rp b f cn Rom (21) PV MODULES g ACCESSAAV\1 \� 1/\[/-\AAAA , 1 f eVENTILATION-18"- per! SIJNation VENTILATION-18"- SUNATION SOLAR SYSTEMS III REMINGTON BLVD RONKONKOMA KY 11779 vvvv NSTALLE ���� (IST) o (S) PV MODULES I Nu BELLRR DRIVEWAY WIFIROOF CUSTOMER INFO ACCESS SAILOR RESIDENCE "- V V LLEY AC ESS AC 69 Fd+ vvvv -36 -36" _= 2130 GRAND AVE =B (B) MATTITUCK 11552 = JOB NUMBER s 19994 DATE GROUND ACCE99 5.G. 1 NOTES FRONT OF HOUSE-FACING STREET I N/A url 8324.1 ACCESS AND PATHWAYS—ROOF ACCESS, PATHWAYS AND SPACING REQUIREMENTS FOR SOLAR PHOTOVOLTAIC SYSTEMS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS 8324.1.1 THROUGH R324.1.6 EXCEPTION(S) I. ROOF ACCESS, PATHWAYS AND SPACING REQUIREMENTS NEED NOT BE PROVIDED WHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED, OR WHERE VERTICAL VENTILATION TECHNIQUES WILL NOT BE EMPLOYED 2. DETACHED NON—HABITABLE GROUP U STRUCTURES. R324.1.4 SINGLE RIDGE ROOFS—PANELS, MODULES OR ARRAYS INSTALLED ON ROOFS WITH A SINGLE RIDGE SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO 36 INCH WIDE(514MM)ACCESS PATHWAYS EXTENDING FROM THE ROOF ACCESS POINT TO THE RIDGE. ACCESS PATHWAYS ON OPPOSING ROOF SLOPES SHALL NOT BE DRAWN BY LOCATED ALONG THE SAME PLANE AS THE TRUSS, RAFTER OR OTHER SUCH FRAMING SYSTEM THAT SUPPORTS THE PATHWAY. JAYSON MORALES EXCEPTION(S) REVISION I. ROOFS WITH SLOPES OF 2 UNITS VERTICAL AND 12 UNITS HORIZONTAL(16.6 PERCENT)AND LESS. DATE DESIGNER NOTE 2. STRUCTURES WHERE AN ACCESS ROOF FRONTS A STREET, DRIVEWAY OR OTHER AREA READILY ACCESIBLE TO EMERGENCY RESPONDERS. 82219 N/A NIA 3. ONE ACCESS PATHWAY SHALL BE REQUIRED WHEN A ROOF SLOPE CONTAINING PANELS, MODULES OR ARRAYS IS LOCATED NOT MORE THAN 24 INCHES (610MM) >oc>oc N/A NIA VERTICALLY FROM AN ADJOINING ROOF WHICH CONTAINS AN ACCESS ROOF >000c NIA NIA R324.1.6 ROOFS WITH VALLEYS —PANELS AND MODULES SHALL NOT BE LOCATED LESS THAN 18 INCHES(451 MM)FROM A VALLEY. >(X>Orxx. N/A N/A EXCEPTION(S) ---CALE I. ROOFS WITH SLOPES OF 2 UNITS VERTICAL AND 12 UNITS HORIZONTAL(16.6 PERCENT)AND LESS. N.T.S. R324.1.1 ALLOWANCE FOR SMOKE VENTILATION OPERATIONS—PANELS AND MODULES SHALL NOT BE LOCATED LESS THAN IS INCHES (45-1 MM)FROM A RIDGE OR PEAK TITLE'ROOF ACCESS PLAN EXCEPTIONS) A-2 I. WHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED OR WHERE VERTICAL VENTILATION METHODS WILL NOT BE EMPLOYED BETWEEN THE UPPER MOST PORTION OF THE SOLAR PHOTOVOLTAIC SYSTEM AND THE ROOF RIDGE OR PEAK. 2. DETACHED GARAGES OR ACCESSORY STRUCTURES. GROUND 4ER ACCESS CIRCUIT 1 (01 01 r e'sr 3 �d ROOF"— 2- f/\E/ 7 , o' A 36ESS O 117\ �aL SUSoWa,ltNation p SUNAVON SOLAR SYSTEMS III REMINGTON BLVD CIRCUIT 3 RONKONKOMA NY.IMJ NYSERIPA INSTALLER NUMBER 4355 a1\[717\11\11\V\ CUSTOMER INFO SAILOR RESIDENCE VENTILATION — 18" — 2130 GRAND AVE MATTITUCK 11952 VENTILATION — 18" — I JOB NUMBER 19994 DATE 5.1 .19 NOTES (115T) o FZ I N/A ° ACCESS DRIVEWAY UJIFI ROOF —36"— VA Y V I I PY -- AC ESS AC SS 36",— DrJ I SP S CIRCUIT 3 GROUND ACCESS DRAWN BY JAYSON MORALES REVISION DATE DESIGNER NOTE FRONT OF HOUSE — FACINGS STREET X >oc>oc NIA N/A >«>«. NIA NIA XX>o N/A NIA >000cxx NIA NIA SCALE N.T.S. TITLE CIRCUIT DIAGRAM uM A=3 013 0-1 -�� SUNation ` Sobr 6.rt.noNE Oa UTILITY SERVICE SUNATION SOLAR SYSTEMS 111 REMINGTON BLVD RONKONKOMA N.Y 11119 1 2 II 12 ENPHASE INSTALLER MICRO — — NUMBER SUPPLY SIDE p� Qr INVERTER Lv Lv CONNECTION CUSTOMER INFO (TYP) MODULE J-BOX 5 SAILOR RESIDENCE (TTP) PLAQUE PLAQUE SERVICE DISCONNECT SERVICE DISCONNECT 2130 GRAND AVE CIRCUIT I 10 COMBINER PANEL 2 OF 2 1 OF 2 (ACTIVATES RAPID SECOND DISCONNECT MATTITUCK 11952 PV MODULE LOCATED NEXT TO (Typ ATTIC ��AGEErEN SHUTDOWN) BINARY DISCONNECT 200A METER PAN JOB NUMBER (12)LG318QIG V5 MODULES W/ ROOF MOUNTED ST NO OF2 �, LOCATED IN MAIN MAIN 1999 SERVICE PANEL (12)ENPHASE IQIPLUS-12-2-US 9OLADEGK 2P 20A DATE I 2 MICRO-INvERTERS IN PARALLEL 8 5 �1 �.�. M . 11 ir p 2P20A �1 ENCLOSURE1 C3 SERVICE RATEDNOTES 2P 20A 60A 1 MN 60A 2P 20A OCPO J MIK 22K AIC I N/A . • . 3 MAIN SERVICE CIRCUIT EXTERIOR WALL PANEL d 6 STRING OF I (9)LG310QIG-V5 MODULES W/ I (9)ENPHASE IQIPLUS-12-2-Us CONDUIT AND CONDUCTOR SCHEDULE I 2 MICRO-INVERTERS IN PARALLEL � S TAG DESCRIPTION OR CONDUCTOR NUMBER OF CONDUIT CONDUIT RUN BUILDING GROUNDING CONDUCTOR TYPE GAUGE CONDUCTORS TYPE SIZE LENGTH ELECTRODE o' Che MEGOATTA. I I ENPHASE Q-GABLE 12 6 N/A N/A 20' 2 YPE NM 10 6 N/A N/A 50' 3 HWN-2 10 6 PVC SCH. 80 1.25" 15' CIRCUIT 3 J GC/GEC 6 I PVC SCH. 80 1.25" 15' d HWN-2 6 3 PVC SCH. 80 1.25" 5' STRING OF GC/GEC 6 1 PVC SCH. 80 1.25" 5' (8)LG310QIC-V5 MODULES (8)ENPHASE IQ1PLUS-12-2- 5 HWN-2 (o 3 PVC SCH. 80 1.25" 10' MICRO-INVERTERS IN PARALLEL TO RAIL(TYP) 6 EG 6 1 PVC SCH. 80 0.50" 10' DRAWN BY JAYSON MORALES SCALE N.T.S. TITLE ONE-LINE DIAGRAM E- 1 SUNation Solar..„.nva M TAG LABEL QTY. LOCATION NOTE EXAMPLES SUNATION SOLAR SYSTEMS ITI REMIINGTON BLVD RONKONKOMA N.Y 11115 "''" J01"F " " 1 A EVERY SEPERATION BY ENCLOSURES/WALL5/ OQ 12 DC CONDUITS NY5ERDA PARTITIONS/CEILINGS/FLOORS OR NO MORE THAN 18 4 M1/ — " INSTALLER A %+75-329 21)t a 4E'�990 33iE i 21 C �-�•--%•isyril,ei _ NUMBER A W A RN IN - CUSTOMER INFO DO NOT DISCONNECT I SPLICE/COMBINER 1 a ANY COMBINER BOX IF USED ' SAILOR RESIDENCE ` UNDER LOAD -,. ._ 2130 GRAND AVE MATTITUCK 11952 '.,,. . • • ••.t • JOB NUMBER _ 1 STRING I n �)UNuw S.W S�..., • • 19994 89 STRING 2 110-9154 _ DATE S STRING 3 1 OF EACH A AC DISCONNECT 750.9454 f NOTES � � '0 3 SOURCE CIRCUITS COMPLETE VOLTAGE AND CURRENT VALUES ON i L NSA DISCONNECT LABEL AS NEEDED :C 1r Tl \"Ooif/ w . . 1 YORK 009 2 X05-102 2014'NECE9O t71E1 _ • 1JWARNING I AC SERVICE I OF EACH A FUSED AC DISCONNECT Service O ELECTRIC SHOCKHAIARD DISCONNECTING COMPLETE VOLTAGE AND CURRENT VALUES ON of CK)NolIoLrm10"fols MEANS DISCONNECT LABEL Primary Service Disconnecr T LamsrS�!1BCr M:%!t.AEaf.D L6105t)E9 suv?t tr!rgltEO in THE OPEN POSITION Located in Mein Service Pans B i ■t This Su1Wmq is-pPW with an Q - F Interconnecls0 Electric Power 7! Producilon Scarce 1I 1 1 � • �� Q1 Bele•Melo IleNeie QI•G•o0.0YluW4•rer. Ysaf Bwae �� rna — W1k ••sr •r i.r•c OI MAIN DISCONNECT I OF EACH A BUILDING MAIN DISCONNECT PANEL PANEL 'Service DisconnW D - - �AIX a e q e eoplppee caro+an INetcaAllMeO Electric Paver DRAWN DY ucdon lowct i 1 1 I JAYSON MORALES "i` I E scALE O I UTILITY METER A PSEQG UTILITY METER •r_e •s•s_ •srer. W� N.T.S. .et= •rl•ITi e.► stru�er.!.�r.•4.e TITLE LADELNG SGHEMATtC L- 1 SUNatiorl SUNATION SOLAR SYSTEMS 111 REMINGTON BLVD RONKONKOMA N.Y 11119 y t g t NYSERDA }. t y! INSTALLER 4 rf NUMBER tf; CUSTOMER INFO SAILOR RESIDENCE 2130 GRAND AVE MATTITUCK IIS52 `i^-P.i NUMBER � 4 ., . DATE �,�• NOTES J.4 �' " r`• IT'- -_ 1 N iF y C) ARRAY LOCATIONS ARRAY LOCATIONS SATELLITE IMAGE ` �-'�ii�"kM�R� '✓ VIA GROUND VIA ROOF x' f•, 'y �� `�`1 � � �� �,a „tag AF t • P DRAWN BY JAYSON MORALES N.T.S. SOUTH VIEW PROPOSED EXISTING METER TITLE.PHOTOS VIA ROOF EQUIPMENT LOCATION AND MDP G= 1