Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
43884-Z
gUFFflI�Cd� Town of Southold 1/13/2020 P.O.Box 1179 53095 Main Rd �p Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 40994 Date: 1/13/2020 THIS CERTIFIES that the building FIRE ALARM Location of Property: 9095 Sound Ave,Mattituck SCTM#: 473889 Sec/Block/Lot: 121.-2-2.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/11/2019 pursuant to which Building Permit No. 43884 dated 6/18/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: fire alarm in an existing restaurant as applied for. The certificate is issued to 9095 Sound Ave LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED o Authorized Signature tFfn�� TOWN OF SOUTHOLD BUILDING DEPARTMENT a TOWN CLERK'S OFFICE ca 5 . � SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 43884 Date: 6/18/2019 Permission is hereby granted to: 9095 Sound Ave LLC 165 Oliver St Riverhead, NY 11901 To: install a new fire alarm in an existing restaurant as applied for. At premises located at: 9095 Sound Ave,'Mattituck SCTM #473889 Sec/Block/Lot# 121.-2-2.1 Pursuant to application dated 4/11/2019 and approved by the Building Inspector. To expire on 12/17/2020. Fees: NEW COMMERCIAL, ALTERATION OR ADDITIONS $250.00 CO -COMMERCIAL $50.00 i Total: $300.00 Building Inspector Form No-6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must'be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. ` B. For existing buildings (prior to April 9, 1957)non-conforming uses, or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is - denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00' Q Date. New Construction: Old or Pre-existing Building: (ch?015 �;..Olfjlvo hz Ncy iqz eck one) Location of Property House No. Street Hamlet �y Owner or Owners of Property: '7 015 So O''JO 4Lie— Z–L G Suffolk County Tax Map No 1000,Section Block Lot Subdivision Filed Map. Lot: I Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ Z, Pr Applicant Signature L/37 OF SOUTyOIo * # TOWN OF SOUTHOLD BUILDING DEPT. 0 courm�a 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION/CAULKING [ ] FRAMING /STRAPPING [ ] FINAL i [ ] FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION i [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATIONS [ ] PRE C/O REMARKS: DATEl��d�a�U INSPECTOR FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(1ST) ..................._.................. 'FOUNDATION (2ND) a O ROUGH FRAMING& PLUMBING H IZ INSULATION PER N.Y: H STATE ENERGY CODE FINAL ADDITIONAL COMMENTS z • rn J d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502Q Survey Southoldtownny.gov PERMIT NO. 5 (J Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined ,20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved E 20-11 Mail to: Disapproved a/c Phone: V 7 Expiration ,20 11 CW / ?/ 89/ S060 NO Buildingor D PPLICATI ON FOR SUILIING PERMIT APR 1 1 2019 Date ��� a , 20 INSTRUCTIONS TOWN O3FSO a. This applicationl'ffiL We completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) 7 -rue vl 14/e— Med 6l2D IyIV J JZO (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect,"engineer, general contractor, electrician, plumber or builder Name of owner of premises 7095 L L C (As on the tax roll or latest deed) If applicant i a oration, signature of duly authoriz d officer d (Name and titleoFcolporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. Ij,0006 N700 1. Location of land on which proposed work will be �qn qog�- S0006 �✓� IN1 �r �fi c. y l°tSZ House Number Street Hamlet County Tax Map No. 1000 Section 1 2�,00 Block 0 2,106' Lot 00:i 001 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Af&4n,U,fgs,4 6/m b. Intended use and occupancy k0+6 of 14K 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work 16e(5 61S LL,q'�DY� (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises d 50d NI Address 165 d I�V� �. Phone No*?1'72,7-761 Name of Architect ddress Phone No Name of Contractor 0,1J5iiLur&- Y Address I 7 IL)ePaf Ave- Phone No. LQ J —V�7k7 d►90J�)94> A1,V. 11703 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF S LLk,,j A1 �`I P : 1 N _ f�� mm)'eing duly sworn, deposes and says that(s)he is the applicant (Name bf individual signing contract) above named, (S)He is the (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the s i work and to make and file this application; that all statements contained in this application are w e ge a d belief; and that the work will be performed in the manner set forth in the a lication ed%qKR 10 ANNA p pp 0JA State of New York No.01AD6302063 Sworn to before me thi Qualified in Suffolk Apr r28y2022 My Commission Expires Ap day of C i 20� 7 yj ' Notary Public Signature of Applicant 6 4--h t� r11% THE FIRE ALARM SYSTEM HEREIN HAS BEEN DESIGNED IN ACCORDANCE WITH NEPA ARCHITECT: 72 AND LOCAL ORDINANCES. HOWEVER NO PARTY HEREIN WARRANTS NOR REPRESENTS THAT THE FIRE ALARM SYSTEM WILL IN ALL CASES PREVENT THE LOSS OF LIFE AND/OR PROPERTY, LOCAL AUTHORITIES HAVING JURISDICTION MAY REQUIRE ADDITIONAL MODIFICATIONS AT THE TIME OF PLAN APPROVALSAND OR AT FINAL SITE INSPECTION. ANY SYSTEM MODIFICATIONS, ADDITIONS OR ALTERATIONS SHALL BE DONE IN ORDER TO COMPLY WITH THE VILLAGE, TOWN OR COUNTY FIRE MARSHALL'S OFFICE, AT THE CUSTOMERS EXPENSE. DESIGN THE FIRE ALARM SYSTEM HEREIN CONSISTS OF A FULLY ADDRESSABLE FIRE ALARM SYSTEM, THE INITIATING AND INDICATING DEVICES USED SHALL BE AS 11 ROSLYN STREET ISLIP TERRACE,N.Y. 11752 FOLLOWS. P: 631-365-7901 OO H O 0 0 E:jfgarci@yahoo.com❑ REMOTE ANNUNCIAT❑R INFORMATION FIRE ALARM CONTRACTOR: A) THE REMOTE ANNUNCIAT❑R SHALL BE READABLE AND VISIBLE FROM OUTSIDE THE MAIN ENTRANCE, ARROW SECURITY SYSTEMS,INC 8co 37 MECH. RM SMOKE AND HEAT DETECT❑RS MEDFOERAVENUE EDFORD,N.Y.1]763 A) EACH SMOKE OR HEAT DETECTOR SHALL NOT BE INSTALLED WITHIN 4' OF A Phone:631-289-0767 Fax:631-654-0552 FSR S I D E W A L L. I Email:ARROW@ARROWSECURITYSYSTEMS.COM B) EACH WALL MOUNTED SMOKE OR HEAT DETECTOR SHALL BE INSTALLED BETWEEN NYS license#12000004781 4' & 12' DOWN FROM CEILING. - PION C) EACH 5 SUPPLY DIF�USERKE EORCRETURNALL A R NOT OPENING,INSTALLED WITHIN 36' FROM AN AIR � V; rORE D) EACH SMOKE DETECTOR SHALL NOT BE INSTALLED WITHIN 36' H❑RIZ❑NTAL PATH FROM THE TIP OF THE BLADE OF A CEILING SUSPENDED FAN, APP OVED AS NOTED E) AS PER NEW YORK STATE FIRE CODE SECTION 907,2, HEAT DETECTION SHALL O NOT BE REQUIRED IN AREAS PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM S THAT IS CONNECTED TO THE BUILDING FIRE ALARM SYSTEM, BTHRM MANUAL FIRE ALARM PULL STATIONS FEE: b BY: A COMPLY WITH t CODE. Li A) THE OPERABLE PART OF EACH PULL STATION SHALL BE MOUNTED 42'-48' FROM NOTIFY BUILDING DEPARTMENT AT NEW YORK ST/` OWE �`S THE FINISHED FLOOR. 765-1802 8AM TO 4PM FOR THE AS REQUIPFn �; NDITIONS O'= L6B) EACH PULL STATION SHALL BE LOCATED S❑ THEY ARE CONSPICUOUS, FOLLOWING INSPECTIONS: CRAWLSPACE F s CN❑EACH PULL UCTED STATION SHALL BE LOCATED QITHIN 5' OF THE EXIT DOORWAY AND ACCESSIBLE, 1. FOUNDATION - TWO REQUIRED O 0 ,o, '� OPENING. FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING OVER P D) EACH PULL STATION SHALL BE LOCATED ON BOTH SIDES OF GROUPED OPENINGS 3. INSULATION "o USTEES OVER 40 IN WIDTH AND WITH 5 OF EACH SIDE OF THE OPENING„ O O NOTIFICATION APPLIANCES 4. FINAL - CONSTRUCTION MUST 75 A) ALL AUDIBLE DEVICES SHALL HAVE A TEMPORAL-3 CODE. BE COMPLETE FOR C.O. DRY STORAGE BTHRM B) A SUFFICIENT NUMBER OF AUDIBLE DEVICES SHALL BE PROVIDED SO THAT THE ALL CONSTRUCTION SHALL MEET THE OFIRE ALARM SYSTEM IS AUDIBLE IN ALL PARTS OF THE BUILDING. REQUIREMENTS OF THE CODES OF NEW S C) ALL STROBE APPLIANCES SHALL HAVE A SYNCHRONIZED LIGHT PULSE OUTPUT YORK STATE. NOT RESPONSIBLE FOR OCCUPANCY REMAIN ACTIVE AFTER SILENCE FUNCTION OCCURS. DESIGN OR CONSTRUCTION ERRORS. c �+ O STROBE D) THE C OMB❑INA� ❑N HAPPL AONCES SHALL BE MOUNTED LENS OF ALL WALLMATN80 D ABOVE ETHE AF UDIBLE NISHED ��c IJ U�' f XOFFlCE FLOOR, WITHOUT Cif ;" =KATE E) SPRINKLER WATERFL❑W SHALL BE NON-SILENCEABLE (INCLUDES ALL HORN ELECTRICAL STROBES, STROBES AND BELL) INSPECTION REQUIRED QF OCCUPA" F HEATING VENTILATI❑N AIR CONDITIONING (HVAC) INFORMATION �.� 16 A) PLEASE REFER TO PLAN FOR HVAC UNIT INFORMATI❑N. STAFF BTHRM B) DUCT SMOKE DETECTORS SHALL BE INSTA:.LED AS REQUIRED BY THE 7MECHANICAL CODE OF NEW YORK STATE (SECTI❑N 606- SMOKE DETECTION SYSTEMS O CONTROL) AND IN ACCORDANCE WITH NFPA-72 & MANUFACTURER SPECIFICATIONS. WIRING MANUFACTURER GENESIS CABLE CO. AIM AS PER SECTION 606, DUCT SMOKE DETECTORS ARE NOT REQUIRED WHEN ALL , PORTIONS OF THE BUILDING SERVED BY THE AIR DISTRIBUTI❑N SYSTEM AREA WIRING SPECIFICATION CHART 'S PROTECTED BY AREA SMOKE DETECTORS CONNECTED TO A FIRE ALARM SYSTEM IN ACCORDANCE WITH SECTION 907.2 OF THE FIRE CODE OF NEW YORK STATE AND W.I. COOLER NFPA-72. 18 ANG FPLP WIRE: INTIATING ZONES WP O C) EACH HVAC UNIT SHALL SHUTDOWN UPON RECEIPT OF ANY FIRE ALARM SIGNAL 16 ANG FPLP WIRE: INTIATING ZONES Ol R� BASEMENT IN ACCORDANCE WITH THE MECHANICAL CODE OF NEW YORK STATE (SECTION 606.4) # A, D. MANUAL ACTIVATION SHALL BE REQUIRED FOR A FAN RESTART INDEPENDENT OF SYSTEM RESET. #16 WG FPLP WIRE: SIGNAL CIRCUIT O SEQUENCE OF OPERATI❑NSI A) NORMAL STATE- FIRE ALARM SYSTEM SHALL PROTECT PREMISES VIA INITIATING #18 / WG FPLP WIRE: SIGNAL CIRCUIT MECH. RM C/) DEVICES. B) ALARM CONDITION- ACTIVATION OF ANY INITIATING DEVICE SHALL REPORT AN #12 A NIG BX WIRE: 120 VAC/GROUND ALARM CONDITION TO THE FACP AND IMMEADIATELY NOTIFY CENTRAL STATI❑N. UPON AIM O ALARM CONDITION, THE FIRE DEPARTMENT Slq/4!-L BE NOTIFIED VIA CENTRAL STATION, OCCUPANTS SHALL BE NOTIFIED VIA NOTIFICATION APPLIANCES & ALL OUTPUT/ CONTROL FUNCTIONS SHALL BE ACTIVATED AS REQUIRED (HVAC OSHUTDOWN, ELEVATOR RECALL, ETC.), W11 C) SUPERVISORY CONDITION- ACTIVATI❑N 1-Y" A TAMPER SWITCH OR MALFUNCTION "P AIM OR/F THAT HINDERS THE PERFORMANCE OF THE FIRE ALARM SYSTEM SHALL REPORT A TROUBLE C❑NDITI❑N TO THE FACP AND IMMEDIATELY NOTIFY CENTRAL STATION, W.I. FREEZER F _ UPON A TROUBLE CONDITION, THE INSTALLATION CONTRACTOR SHALL BE NOTIFIED VIA CENTRAL STATION & FACP SHALL SOUND TONE, W.I. COOLER D) CENTRAL STATION NOTIFICATION SHALL BE MADE DIRECTLY FROM FACP, EXTERNAL COMMUNICATOR ❑R BY MAIN BUILDING ,FACP IF FACP IS A SUB-PANEL. GENERAL NOTES, 1) THE FIRE ALARM INDICATED ON THE DRAWINGS HEREIN HAS BEEN DESIGNED IN ACCORDANCE WITH 907,2.1 OF THE 2015 INTERNATI❑NAL FIRE ALARM CODE ADOPTED BY NYS & NFPA 72, 14- 2) EXACT LOCATION IN ROOM TO BE VERIFIED IN FIELD. 3) FIRE ALARM CONTROL PANEL OR A REMOTE ANNUNCIATOR SHALL BE INSTALLED AT THE MAIN ENTRANCE A MANNERAND READABLE CELLAR FLOOR FIRE ALARM PLAN THE EXTERIOR OF THEIN BUILD NG. THISHERE REMOTEI A NUNDCIATORI BLE WILL NOT BE CAPABLEO F CONTROLLING ANY FUNCTION OF THE FIRE ALARM SYSTEM AND WILL BE ANNUNCIATION SCALE: 3/16" = 1'-0" ONLY. GENERAL NOTES: 4) ANY/ALL KEYS AND OR TOOLS REQUIRED TO RESET ALL COMPONENTS OF THE FIRE ALARM SYSTEM WILL BE LEFT ON SITE. 1 ) The fire alarm indicated on the drawings herein has been designed in accordance (THIS INCLUDES PANEL KEYS AND PROPER SIZE ALAN KEYS.) 5) 24 HOUR EMERGENCY SERVICE FOR FIRE ALARM CONTACT SHALL BE with 907Y1 bf Trfit,,"M Ffhffffi`btional Fire Alarm Code adopted by NYS. CONSPICUOUSLY POSTED ON THE FIRE ALARM PANEL. ALARM CONTACT MUST BE 1 FIRE M VRSHALL SUBMISSION 4/02/19 J.G. s is in compliance with NFPA 72 and local EQUIPMENT LIST - FIRE DETECTION AVAILABLE FOR 24 HOUR SERVICE. 2. The fire alarm indicated on the drawings p 6) CONCEALED DEVICES SHALL BE ACCESSIBLE FOR SERVICE AND HAVE A REMOTE QTY SYMBOL PART NAME MODEL NO, MFG. DESCRIPTION MOUNTING REQUIREMENTS ALARM INDICATOR. NO. DESCRIPTION DATE INITIALS ordinances. FIRE ALARM FLUSH OR SURFACE MOUNT BOX 7) EACH INITIATING DEVICE SHALL BE CLEARLY LABELED FOR ITS RESPECTIVE ZONE , 3. All carbon monoxide detectors shall emit a temporal 3 audible pattern and 1 FACP CONTROL PANE ES-200X FIRELITE INTELLIGENT ADDRESSABLE FIRE ALARM CONTROL PANEL 72' AFF TO TOP OF ENCLOSURE CIRCUIT AND / OR ADDRESS. S E A 8) ALTERATION AND / OR CHANGES TO THE FIRE ALARM PLAN SET SHALL BE trigger an alarm condition to the monitoring station. 1 FAA FIRE ALARM ANNUNCIATOR ANN-80 FIRELITE LCD FIRE ALARM ANNUNCIATOR FLUSH OR SURFACE MOUNT BOX$L' AFF T❑ TOP OF ENCLOSURE PROHIBITED EXCEPT UNDER DIRECTION OF A LICENSED PROFESSIONAL OR THE AUTHORITY HAVING JURISDICTION. WP FIRELITE = 4. Building is Not Sprinklered 3 O HEAT DETECTOR FIRELITE RATE—ANTICIPATI❑N HEAT DETECTOR R/F 302-ET-135 FIXED TEMP. 135 DEG. ADDRESSABLE INTELLIGENT ADDRESSABLE PHOT❑ELECTRIC SINGLE GANG, 4' SQUARE OR OCTAGON 28 O SMOKE SD355 FIRELITE SMOKE DETECTOR WALL ❑RDETECTOR CEILING MOUNT Elta:€i€ft: WALL MOUN EXTERIOR T P2RK SYS. SENSOR FIRE ALARM HORN/STROBE MULTI—CANDELA SINGLE GANG. 4' SQUARE OR OCTAGON FIRE ALARM APPROVAL: ,03/j 32 t4oe,, 1 %P HORN/STROBE 24V RED. 'WP' INDICATES WEATHERPROOF WALL OR CEILING MOUNT ��Fc NE`Ny UQA 12 75 WALL MOUNT P2RL SYS, SENSORHORN/STROBE MULTI—CANDELA X / SINGLE GANG ' �o� HORN/STROBE FIRE ALARM W SQUARE B❑ 24V RED. ' WALL MOUNT ?0 F WALL MOUNT SRL SYS. SENSOR FIRE ALARM STROBE MULTI—CANDELA 4' SQUARE BOX / SINGLE GANG PROJECT TITLE : S STROBE 24VDC (RED) WALL MOUNT FIRE ALARM PLAN FOR 13 Q PULL MANUAL SINGLE BG-12LX FIRELITE INTELLIGENT ADDRESSABLE PALL STATION 48'GTO CENTER❑❑F BOX NC�RTHFORK ROADHOUSE M❑NIT❑R 4' SQ c MMF-300 FIRELITE INTELLIGENT ADDRESSABLE MONITOR MODULE SQUARE BOX 9095 SOUND AVENUE SITE 8 ASM MODULE MATTITUCK,NY 11952 aJ / RELAY 2 FSR MODULE CRF-300 FIRELITE INTELLIGENT ADDRESSABLE RELAY MODULE 4' SQUARE BOX T I T L E SHEET: FIRELITE FIRE ALARM PLAN & GENERAL RxIE=rF�talsn<_> 1 O94 HEAT DETECTOR 302-194 FIRELITE HEAT DETECTOR f'r.,�f�ve r!Red ADDRESSABLE TEMP, 194 DEG. NOTES & LEGEND ADDRESSABLE ADDRESSABLE HEAT SINGLE GANG, 4' SQUARE OR OCTAGON DATE 03-28-19 3 O HEAT DETECTOR H355 FIRELITE FIXED TEMP.135 DEG.. DRAWING NO.: WALL ❑R CEILING MOUNT 4CO 4' SQUARE BOX / SINGLE GANG 3 DETECTOR CO1224T SYS. SENSOR CONVENTION CARBON MONOXIDE DETECTOR PROJECT NO.: 19-006 c4 �caun�Avc: CO �'!'"!c'3 Vit; 1 ANSUL — — — EXISTING ANSUL SYSTEM RELAY 54' DRAWN B AFF T❑ T❑P ❑F ENCLOSURE Y• J.G. ADDRESSABLE INTELLIGENT ADDRESSABLE BEAM SM❑KE1 1 BEAM BEAM SMOKE BEAM355 FIRELITE DETECTOR SINGLE GANG. 4' SQUARE OR OCTAGON CHECKED P Y: J.G. DETECTOR WALL ❑R CEILING M❑UNT SCALE: AS 'VOTED THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PRt)P'ERTY OF THE ARCHITECT.ALTERATION KEY MAP OR ADDITIO v TO THESE PLANS IS A VIOLATION OF NORTH SECTION 7209 OF THE NEW YORK STATE EDUCATION scab N.rs LAW. ARCHITECT: WP F 0 D DESIGN MECH. RM a 11 ROSLYN STREET ISLIP TERRACE,N.Y. 11752 P:631-365-7901 O O E:jfgarci@yahoo.com WAITING AREA � Q FIRE ALARM CONTRAC['OR: ARROW SECURITY SYSTEMS,INC 37 TUPPER AVENUE MEDFORD,N.Y.11763 S KITCHEN Phone:631-289-0767 Fax:531-654-0552 Email:ARROW@ARROVISECURITYSYS'I'EMS.COM �O 75 F NYS license#12000004780 F F F 0 s BTHRM 75 WAITING AREA O H I 75 AIM °, F O AIM H CO WAITING AREA 194 1THp 7�0Li JRM. O F a SERVICE AREA O SO DINING AREA O 75 F WIRING 'IMANUFACTURER GENESIS CABLE CO. ° o ,Ov WIRING SPECIFICATION CHART ® 13 ® 1 #18 AWG FPLP WIRE: INTIATING ZONES 0 #16 AWG FPLP WIRE: INTIATING ZONES �° ° mea F #16 AWG FPLP WIRE: SIGNAL CIRCUIT o` �c a° #18 AWG FPLP WIRE: SIGNAL CIRCUIT DINING AREA CO � � #12 AIG BX WIRE: 120 VAC/GROUND S � ��' C � CC .0 qj 6co Q) �o -Q� �� Q\ , ° GENERAL NOTES: 1 ) The-fire alarm indicated on the drawings herein has been designed in accordance a with 907.2. 1 of the 2015 International Fire Alarm Code adopted by NYS. REQUIRED FIRE ALARM SYSTEM 2. The fire alarm indicated on the drawings is in compliance with NFPA 72 and local SEQUENCE OF OPERATIONS ` m� o 0 m � ordinances. System Input 3. All carbon monoxide detectors shall emit a temporal 3 audible pattern and Os 1. Manual Pull Station coo 2. Smoke Detector 00 ® 001 trigger an alarm condition to the monitoring station. 3. Heat Detector ® ® t 4. Building is Not Sprinklered 4. Sprinkler Waterflow/Pressure Switch ® 0 0 ® Q 75 5. Duct Smoke Detector ® 10 e ,0 6. Sprinkler Tamper Switch 0 01 1 6. Sprinkler Hi/Lo Pressure Q F FE F 7. Carbon Monoxide Detector 00 8. Automatic or Alternate Extinguishing System C) 9. 1 Notification Appliance Circuit Short ® 01 1 FIRE MARSHALL SUBMISSION 4/02/19 J.G. EQUIPMENT LIST — EIRE DETECTI❑N 10.1 Ground Fault 0 0 QTY SYMBOL PART NAME MODEL NO, MFG. DESCRIPTION MOUNTING REQUIREMENTS 11.12. Low Open Circuit Battery 1 0 ® NO. DESCRIPTION DATE INITIALS FIRE ALARM FLUSH OR SURFACE MOUNT BOX 1 FFA-z--Pi ES-20OX FIRELITE INTELLIGENT ADDRESSABLE FIRE ALARM 13. FACP Power Failure CONTROL PANEL CONTROL PANEL 72' AFF TO TOP OF ENCLOSURE S EA Ep FIRE ALARM FLUSH OR SURFACE MOUNT BOX ��R �RCy% 1 F"�` ANNUNCIATOR ANN-80 FIRELITE LCD FIRE ALARM ANNUNCIATOR 52' AFF TO TOP OF ENCLOSURE FIRST FLOOR FIRE ALARM PLAN �,�� �� F. WP FIRELITE 3 O HEAT DETECTOR FIRELITE -135 FIRELITE RATE-ANTICIPATION HEAT DETECTOR SCALE: 3/16" = 1'-0" aA R/F FIXED TEMP, 135 DEG, NOTE: BUILDING IS NOT SPRINKLERED � ADDRESSABLE INTELLIGENT ADDRESSABLE PHOTOELECTRIC SINGLE GANG, 4' SQUARE OR OCTAGON 28 O SMOKE: SD355 FIRELITE SMOKE DETECTOR WALL OR CEILING MOUNT WALL MOUNT �� `L DETECTI3R 1 gyp' EXTERIOR P2RK SYS, SENSOR FIRE ALARM HORN/STROBE MULTI-CANDELA SINGLE GANG. 4' SQUARE OR OCTAGON FIRE R E ALARM APPROVAL:P R❑�/A L N �, X317113 y0¢ ' ' P HORN/STROBE 24V RED, WP INDICATES WEATHERPROOF WALL OR CEILING MOUNT F NEIN 75 WALL MOUNT P2RL SYS, SENSOR FIRE ALARM HORN/STROBE MULTI-CANDELA 4' SQUARE BOX / SINGLE GANG 12 gip` HORN/STROBE 24V RED. ' WALL MOUNT MF WALL MOUNT 24VDC (RED) 4' SQUARE BOX / SINGLE GANG AIR DIFFUSER DOOR PROJECT T I T L E : S STROBE SRL SYS. SENSOR FIRE ALARM STROBE MULTI-CANDELA WALL MOUNT 4 FIRE ALARM PLAN FOR MANUAL SINGLE GANG BOX CEILING(OPEN OR ATC) 13 Q PULL STATI❑N BG-12LX FIRELITE INTELLIGENT ADDRESSABLE PULL STATION 48' TO CENTER OF BOX NORTHFORK ROADHOUSE MONITOR MMF-300 FIRELITE INTELLIGENT ADDRESSABLE M❑NIT❑R MODULE 4' SQUARE BOX MIN 3' AWAY 6"MIN. (SEE NOTE 2) ACCEPTED HERE 4" 8 AIM MODULE SMOKE OR HEAT � 12(MAX.) 9095 INTELLIGENT ADDRESSABLE RELAY M❑DUCE MATT9 SOUND AVENUE,952 2 FSR RELAY 4' SQUARE BOX DETECTOR NEVER HERE MODULE CRF-300 FIRELITE TI T L E SHEET: FIRELITE FIRELITE HEAT DETECTOR WALL MOUNTED SMOKE/HEAT 1 094 HEAT DETECTOR 302-194FIXED TEMP, 194 DEG, DETECTOR FIRE ALARM PLAN & LEGEND FACP ADDRESSABLE H355 FIRELITE INTELLIGENT ADDRESSABLE DG„ A SINGLE GANG, 4' SQUARE OR OCTAGON 3 O HEAT DETECTOR WALL OR CEILING MOUNT 5,-0„ DATE 03-28-19 ANN DRAWING NO.: CO C❑1224T SYS, SENSOR CONVENTION CARBON MONOXIDE DETECTOR 4' SQUARE BOX / SINGLE GANG (MAX,) HORN/STROBE OR STROBE 3 ® DETECTOR CO NOTIFICATION DEVICE J PROJECT NO.: 19-006 72"MAX 80„ BOTTOM OF LENS EXISTING ANSUL SYSTEM RELAYA.F.F. ® (96"A.F.F. MINIMUM) w DRAWN BY� 4' AFF TO TOP OF ENCLOSURE 60" 60" o J.G. ADDRESSABLE INTELLIGENT ADDRESSABLE BEAM SMOKE A.F.F. 54" A.F.F. `� 1 BEAM BEAM SMOKE BEAM355 FIRELITE DETECTOR WALL OR CEILINGMOUNT QUARE ❑R OCTAGON A.F.F. FINISHED WALL CHECKED B Y: J.G. FA - 2 DETECTOR 48"TO HANDLE SCALE: AS NOTED FINISHED FLOOR FINISHED FLOOR THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT.ALTERATION OR ADDITION TO THESE PLANS IS A VIOLATION OF /PULL STATION SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. ARCHITECT: DESIGN 11 ROSLYN STREET ISLIP TERRACE,N.Y. 11752 P: 631-365-7901 E:jfgarci@yahoo.com FIRE ALARM CONTRAC MR: ARROW SECUfRITY SYSTEMS,INC 37 TUPPER AVENUE MEDFORD,N.Y.11763 Phone:631-289-0767 Fav 631-654-0552 Email:ARROW@ARR01A'SECURITYSYSTEMS.COM F NYS license#120000047:80 O O� rs CLOSET LIVING ROOM O O 7s �0 CLOSET El OPEN TO BELOW El Fc FILING 3= MINIMUME ) AIR REGISTER SMOKE DETECTOR HORN,/STROBE & STROBE DEVICE STORAGE PULL STATION A.F.F. 4'-0" A.F.F. FL®OIC TYPICAL DEVICE LOCATIONS LOFT AREA STORAGE N.T.S. 7s PBEAM LOFT FLOOR FIRE ALARM PLAN SCALE: 3/16" = 1'-0" NOTE: BUILDING IS NOT SPRINKLERED EQUIPMENT LIST - EIRE DETECTI❑N QTY SYMBOL PART NAME MODEL NO, MFG. DESCRIPTION MOUNTING REQUIREMENTS 1 FIRE MARSHALL SUBMISSION 4/02/19 J.G. 1 FAC P] FIRE ALARM ES-20OX FIRELITE INTELLIGENT ADDRESSABLE FIRE ALARM FLUSH OR SURFACE MOUNT BOX CONTROL PANE CONTROL PANEL 72' AFF TO TOP OF ENCLOSURE NO. DESCRIPTION DATE INITIALS FAA FIRE ALARM ANN-80 FIRELITE LCD FIRE ALARM ANNUNCIATOR FLUSH OR SURFACE MOUNT BOX 1 ANNUNCIATOR 52' AFF TO TOP OF ENCLOSURE SEAL : 3 O wP FIRELITE FIRELITE RATE—ANTICIPATION HEAT DETECTOR ED / HEAT DETECTOR 302—ET-135 �R R/1' FIXED TEMP, 135 DEG, C C N ADDRESSABLE INTELLIGENT ADDRESSABLE PHOTOELECTRIC SINGLE GANG, 4' SQUARE OR OCTAGON Cam — jF' 28 O SMOKE SD355 FIRELITE SMOKE DETECT❑R WALL OR CEILING MOUNT DETECTOR �� �O WALL MOUNT EXTERIOR P2RK SYS, SENSOR FIRE ALARM HORN/STROBE MULTI—CANDELA SINGLE GANG. 4' SQUARE OR OCTAGON H❑RN/STROBE I 1 � 24V RED, 'WP' INDICATES WEATHERPROOF WALL OR CEILING MOUNT * 1 75 WALL MOUNT P2RL SYS, SENSOR FIRE ALARM HORN/STROBE MULTI—CANDELA 4' SQUARE BOX / SINGLE GANG EIRE ALARM A P P R❑V A L; N �� 12 `p' HORN/STROBE 24V RED. ' WALL MOUNT � j� 0 7032 ,yp WALL MOUNT SRL SYS, SENSOR FIRE ALARM STROBE MULTI—CANDELA 4' SQUARE BOX / SINGLE GANG Of NE`N 5 STROBE 24VDC (RED) WALL MOUNT MANUAL BG-12LX FIRELITE INTELLIGENT ADDRESSABLE PULL STATION SINGLE GANG BOX PROJECT TITLE : 13 F PULL STATION 48 TO CENTER OF BOX FIRE ALARM PLAN FOR MONITOR MMF-300 FIRELITE INTELLIGENT ADDRESSABLE MONITOR MODULE 4' SQUARE BOX NORTHFORK ROADHOUSE 8 AIM MODULE RELAY 4' SQUARE BOX 2 FSR MODULE CRF-300 FIRELITE INTELLIGENT ADDRESSABLE RELAY MODULE 9095 SOUND AVENUE, MATTITUCK,NY 11952 FIRELITE FIRELITE HEAT DETECTOR 1 094 HEAT DETECTOR 302-194 FIXED TEMP. 194 DEG, TI T L E SHEET: ADDRESSABLE H355 FIRELITE FIXEDLTEMP135 DEG A L A SINGLE GANG. 4' SQUARE OR OCTAGON LOFT PLAN ' 3 O HEAT DETECTOR WALL OR CEILING MOUNT 3 CO DETECTOR C❑1224T SYS, SENSOR CONVENTION CARBON MONOXIDE DETECTOR 4' SQUARE BOX / SINGLE GANG DATE 03-28-19 DRAWING NO.: 1 EXISTING ANSUL SYSTEM RELAY PROJECT NO.: 19-006 54' AFF TO TOP OF ENCLOSURE DRAWN BY: J.G. ADDRESSABLE INTELLIGENT ADDRESSABLE BEAM SMOKE SINGLE 1 BEAM BEAM SMOKE BEAM355 FIRELITE DETECTOR DETECTOR WALL OR AC ILINGSM❑UNT ❑R OCTAGON CHECKED BY: J.G. FA - 3 SCALE: AS NOTED —11 THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT.ALTERATION OR ADDITION TO THESE PLANS IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. ARCHITECT: /"O�\ QTY QTY QTY QTY DESIGN 13 1 11 ROSLYN STREET ISLIP TERRACE,N.Y. 11752 3 P: 631-365-7901 E:jfgarci@yahoo.com F S BEAM FIRE ALARM CONTRACTOR: \O/ ARROW SECURITY SYSTEMS,INC 37 TUPPER AVENUE MEDFORD,N.Y.11763 Phone:631-289-0767 Fax:631-654-0552 Email:ARROW@ARROW"SECURITYSYSTEMS.COM LOFT FLOOR (LF) (LF) (LF) (LF) NYS license#12000004780 QTY . QTY 14 F I R E QTY QTY ( 1 F) QTY 1 1 1 S 10 LANSUL 8&194 ALAR 1 ( 1 F) AIM QTYCNTRL QTY QTY CEILING 2 6 WP 1 LTEL #1 3MINIMUM/ 1F AIR REGISTER F ,0� ,0\ TEL #2 SMOKE DETECTOR FIRELITE TR HORN/SOBE QTY ( 1 F) & S-MOSE DEVICE 2 ( 1 F) ES-200X FAA FM . " ADDRESSABLE 0 M::�E 0 PULL- STATION FIRE 69-8., QTY QTY A.F.F. 2 2 PANEL D A.F.F. ( 1 F) -� . AIM FLOOR CO 112 VOLTS 2 -TYPICAL CREVICE LOCATIONS 4 N.T.S. V 0 120VAC12 VOLTS L 6 1ST FLOOR 15AMP T BASEMENT QTY QTY 1 1 AIM QTY QTY QTY co 3 3 1 WP (B) FSR QTY AIM " QTY " QTY QTY QTY 3 R/F 2 310N 11 2 /O/ F ku) (B) S � 1 FIRE MARSHALL SUBMISSION 4/02/19 J.G. NO. DESCRIPTION DATE INITIALS SEAL - RE,D ARC,. �0�50�� f��G'°�'oR` N Refer to floor plan for actual device counts Q: ,� , Q'ro "A FIRE ALARM APPROVAL: �TF �(©32 O � OF laE`N PROJECT T I T L E : FIRE ALARM PLAN FOR NORTHFORK ROADHOUSE 9095 SOUND AVENUE, MATTITUCK,NY 11952 TI TLE SHEET: RISER DIAGRAM DATE 03-28-19 DRAWING NO.: PROJECT NO.: 19-006 DRAWN BY: J.G. CHECKED BY: J.G. FA - 4 SCALE: AS NOTED THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF THE ARCHITECT.ALTERATION OR ADDITION TO THESE PLANS IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW.