Loading...
HomeMy WebLinkAbout43794-Z rr ��p�gllEFfl4�pG� Town of Southold 10/29/2019 o P.O.Box 1179 53095 Main Rd py��• ��p�g Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 40817 Date: 10/29/2019 THIS CERTIFIES that the building COMMERCIAL ALTERATION Location of Property: 825 Pacific St.,Mattituck SCTM#: 473889 Sec/Block/Lot: 141.4-11 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 4/29/2019 pursuant to which Building Permit No. 43794 dated 5/24/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: alter existing commerical building to retail store with handicap ramp as applied for. The certificate is issued to Mattituck Hldgs LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 43794 9/12/2019 PLUMBERS CERTIFICATION DATED 10/17/2019Ma tit ck Plui&ng Auton(ZeA Signature SOF oFQF i� TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o . SOUTHOLD, NY y�ol � �aoP BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 43794 Date: 5/24/2019 Permission is hereby granted to: Mattituck Hldgs LLC 825 Pacific St Mattituck, NY 11952 To: alter an existing commerical building to a retail store as applied for per Planning approval. At premises located at: 825 Pacific St., Mattituck SCTM # 473889 Sec/Block/Lot# 141.4-11 Pursuant to application dated 4/29/2019 and approved by the Building Inspector. To expire on 11/22/2020. Fees: NEW COMMERCIAL, ALTERATION OR ADDITIONS $1,363.60 CO -COMMERCIAL $50.00 Total: $1,413.60 Building Inspector Form No_6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. ' B. For existing buildings (prior to April 9, 19S7) non-conforming uses, or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate'of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.000- Date. !!00j t�Vl I New Construction: Old or Pre-existing Building: (check one) Location of Property: � )C(c ouse No. Street Hamlet Owner or of Property: 9 Suffolk County Tax Map No 1000, Section Block Lot Subdivision Filed Map. Lot: t Permit No. Dat�of rmit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ Applica na e ®��OF SO(/l�®l Town Hall Annex ~ ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 11794W. sean.devlin@town.Southold.ny.us Southold,NY 11971-0959 r1h • a0 101�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To Mattituck Hldgs. LLC Address: 825 Pacific St city Mattituck st. NY zip: 11952 Budding Permit#: 43794 section 141 Block. 4 Lot 11 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor. DBA: Abstract Electrical License No: 60163-ME SITE DETAILS Office Use Only Residential Indoor X Basement Service Only Commerical X Outdoor X 1st Floor X Pool New Renovation X 2nd Floor X Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt 57 Ceding Fixtures 82 HID Fixtures Service 3 ph Hot Water Gas GFCI Recpt 17 Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser 1 Single Recpt 4 Recessed Fixtures CO Detectors Sub Panel 100A A/C Blower 1 Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures g Time Clocks 1 Disconnect 1 Switches 14 Twist Lock Exit Fixtures 5 Combo SD/CO 3 Other Equipment Plug mold- 28', Exhaust Fans-2, Notes: Transfer switch- Not on C/O Inspector Signature: Date: September 12, 2019 S. Devlin-Cert Electrical Compliance Form As 40 4 ` • fY. Telephone(631)763-1802 Pax ffili117fiV1509. P.O.�$ax 1179 �' • Southold,NY 11971-0959 BUIMING DEPARTMWr TOWN of SOUTHOLD CERTIFICATION {' Date: /d/1 7 1 Building Permit No. 47 3 Owner: 4 IT;,TU (Please print) / Plumber: ••T0C � yj nrlO (Please print) I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. �um ers Signature) Sworn to before me this day of � 20-a— ' CHELSEA L. CHALONE Notary Public, State of New York Registration#01 . 62871ti6' Qualified In Suffolk Cou2n0ty ., .. Commission Expires Aug. - Notary Public, ), � #r1f so TOWN OF SOUTHOLD BUILDING DEPT. Cour'''' 765-1802 INSPEC ION [ ] FOUNDATION 1ST [ UGH PLBG. [ ] ,POUNDATION 2ND [ INSULATION [Vf FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ . ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ECTRICAL (FINAL) [ ] CODE VIOLATION [ CA KING EMARKS: b ,d4mxZ two h, Jfib l W td� w4uS' w � v DATE R c9'I INSPECTOR 01 L4 -Z �o��OF SOUIyOIo / * TOWN OF SOUTHO D. UILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLSG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION 1�tELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE INSPECTOR q$r� ho��OE SO(/T�o� # TOWN OF SOUTHOLD BUILDING DEPT. `ycourrr+��'' 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] UGH PLBG. [ ] FOUNDATION 2ND [ INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATIO [ ] CAULKING REMARKS: NA V t w4 O �5v_ t65 V CIA&M Qj 5&1 4t, KIP InC, P,*,, W.Vv J."I DATE B INSPECTOR LAJPAd SOGIyo L4 3 7 1 h� l0 TOWN OF SOUTHOI BUILDING DEPT. coum, 765-1802 INSPECTIO�N [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) ` [ ] CODE VIOLATION [ ] CAULKING REMARKS: VtAhV, DATE q ILI INSPECTOR OF SOUTyo z�3-7 # TOWN OF SOUTHOLD BUILDING DEPT. courm, 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REM KS: f4� � P C -- 0_UJ�J DATE 10 —q— INSPECTOR aoF souTy - -— o� # TOWN OF SOUTHOLD BUILDING DEPT. `�courmN 765-1802 i INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ]- SULATIOWCAULKING [ ] FRAMING /STRAPPING [ Vf FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION ' [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] PRE C/O REMARKS: S w,&- 606 Otn NA .}i I _ Com w. (im"A (OVV4, Mn ct GP,v, - e- DATE lro / yt9'l INSPECTO Condon Engineering, P.C. New York State Licensed Professional Engineers 1755 Sigsbee Road 631-298-1986 Mattituck,New York 11952 Fax 631-298-2651 May 22, 2019 Mr. Michael Verity Principal Building Inspector Southold Town Building Department 54375 Main Road Southold, New York 11971 Re : Power Equipment Plus-825 Pacific Street, Mattituck, New York Dear Mr. Verity : I inspected the bathrooms in the building and found to appliances to be operational with complete drainage to the septic system. The existing sanitary system is also adequate and can handle the waste for the dry retail use/load. If you have any questions, please call me at 631-298-1986. Yours truly, Con on, :E-- ... ! �- OWE`�` M AY 2 3 2019 New York State Licensed Professional. Engineers 1755 Sigsbee Road 631-298-1986 Mattituck, New York 11952 Fax 631-298-2651 condo nen g i nee ri n g.com September 25, 2019 Mr. Mike Verity Chief Building Inspector Southold Town Budding Department 53095 Route 25 P O Box 1179 Southold, New York 11971 Re:1725 Pacific Street, Mattituck Dear Mr.Verity. After review of ASHRAE 90.1,C503.1 Alterations,the insulation installed in the walls at 725 Pacific Street fall under Exception 3. If you have any questions, please call me at 631-298-1986 Yours truly, ndon, Condon Engineering, P.C. New York State Licensed Professional Engineers 1755 Sigsbee Road 631-298-1986 Mattituck,New York 11952 Fax 631-298-2651 condonengineering.com October 24, 2019 D 4 Mr. Mike Verity Chief Building Inspector OCT 29 2019 Southold Town Building Department 53095 Route 25 P.O. Box 1179 � 1:='f Southold, New York 11971Tit ' ���� a Re: 825 Pacific Street, Mattituck Dear Mr. Verity: After review of ASHRAE 90.1,C503.1 Alterations,the insulation installed in the walls at 825 Pacific Street fall under Exception 3. If you have any questions, please call me at 631-298-1986. Yours truly, . S•..I�.iti lr:l� ``s,m ;, �. �P' 051684 t� °��®FESSION�"�" OFFICE LOCATION: MAILING ADDRESS: Town Hall Annex �QF SO(/rP.O. Box 1179 54375 State Route 25 � 0l0 Southold, NY 11971 (cor. Main Rd. &Youngs Ave.) Southold, NY Telephone: 631765-1938 N www.southoldtownny.gov • ao coum i PLANNING BOARD OFFICE TOWN OF SOUTHOLD September 24, 2019 Mr. Joseph Morgano 2 Fort Lane Montauk, NY 11954 " Re: Approved Site Plan for Power Equipment Plus 825 Pacific'Street, Mattituck SCTM#1000-141.-4-11 TO WN Cie 8a 0 p f ,D Dear Mr. Morgano: The Planning--Board-has-found that-the requirements-of the above-referenced Site-Plan_ _ have been completed based on the site inspection made September 16, 2019. The site is now in conformance with the Approved Site Plan entitled "Power Equipment Plus" prepared by John J. Condon dated August 3, 2018, last revised April 5, 2019; and supports the issuance of a Certificate of Occupancy. This letter does not condone any other changes from the approved Site Plan and approvals from'other agencies; Planning Board approval is required prior to any significant changes to the site. Respectfully,, Donald J. Wilcenski Chairman cc: Michael Verity, Chief Building Inspector James Richter, Stormwater Manager �g1JfFQ(,� SOUTHOLD TOWN FIRE MARSHAL RFisher 631-765-1802 x5028 1 NOTES & COMMENTS robert.fisher@town.southold.ny.us Business/Job: RWe)2, -ro ()l.'PM&I-r �zs P Address: S/B/L: 1 / Date: / ^� I I G[As A4 -- I s - 10-0 � FireN otes-18-2-w-seal.docx • - • • - • r FOUNDATION � . 'FOUNDATION (2ND) ROUGH FRAMING r PLUMBING �-ab , rl mil�,�a7 .� ►��► , , ENERGYINSULATION PER N.Y. . 1 iAt �1 MEN .1005,71N 11,• 1 •N-AL COMrYMNTS I©0 !11,11111C "` 10 .01 INABYWAS i�WAW1.7 i TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying9 TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey Southoldtownny.gov PERMIT NO. �7 Check Septic Form N Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined 5 ,20 ,� Single&Separate Truss Identification Form Storm-Water Assessment Form App 2 9 2019 Contact: Approved '20 _; i 1 Disapproved a/c �Q of Phone: Expiration 120 W '6 7S Buil g for APPLICATION FOR BUILDING PERMIT n !.� Date !� I , 20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings,additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature o applicant or name,if a corporation) i (Mailing address of applicant) State whether p licant .s owne• s ,rint, arc itect, engineer, general contractor, electrician, plumber or builder Name of owner of premises As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on w 'ch prop sed w rk will be done: House Number Street Hamlet County Tax Map No. 1000 Section TM Block. Lot I 7 �. Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy r iu to b. Intended use and occupancy , , EE12%f? ¢ -1t1aAiMLDE 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost ';S-a'(fib ee.paid on filing this application) �A� � d 5. If dwelling, number of dwelling units�, Num ber of dwelling:unirts1 n each floor If garage, number of cars .r 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. P'^ 7. Dimensions of existing structures, if any: Front`-' ,b ,�r ' Rear �� Depth (0(� Height Number of Stories Dimensions of same structure with alterations or additions: Front J Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 2 - b 9. Size of lot: Front c I "..� � Rear L 9 E Depth 350 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated I -PSS 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO� 13. Will lot be re-graded? YES NO>,�, Will excess fill be removed from premises?YES NO 14. Names of Owner of premises dress 0,.VnFV,:AW5 Phone No. st(o q n L Z s qi Name of Architect Address] Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO� * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO� * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY O&W Ehem U)i-r)P,,/2/ being duly sworn, deposes and says that(s)he is the applicant (Name of ind�ivp'�al signing contract) above named, (S)He is the (/v 1 6& ()Wlez (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this t� day of 20 )q No ary Public ACEY L. D Signaturescan NOTARY PUBLIC,STATE OF NEW YORK NO.01 DW6306900 QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30,2 OFF,CE LOCATION: MAILING ADDRESS: 'Town Hall Annex *oE SOUryo ' P.O. Box 1179 54375 State Route 25 ,`O l0 Southold, NY 11971 (cor. Main Rd. &Youngs Ave.) Southold, NY � � Telephone: 631 765-1938 cn www.southoldtownny.gov PLANNING BOARD OFFICE TOWN OF SOUTHOLD April 23, 2019 Mr. Joseph Morgano 2 Fort Lane Montauk, NY 11954 Re: Final Determination - Site Plan for Power Equipment Plus 825 Pacific Street, Mattituck SCTM#1000-141-4-11 Dear Mr. Morgano: The following resolutions were adopted at a meeting of the Southold Town Planning Board on Monday, April 22, 2019: WHEREAS, this site plan is for the proposed conversion of an existing 3,011 sq. ft. auto garage to an equipment repair/service/sales center, an existing ±2,800 sq. ft. building to- remain as storage, and construction of 19 parking stalls; all on 1.17 acres in the HB Zoning District.; and WHEREAS, on October 22, 2018, Eileen Wingate, authorized agent, submitted a Site Plan Application for review; and WHEREAS, on October 24, 2018, Eileen Wingate, authorized agent, submitted information and materials for review; and WHEREAS, on November 19, 2018, Eileen Wingate, authorized agent, submitted information and materials for review; and WHEREAS, on November 19, 2018, the Planning Board found the application incomplete for review and required revised site plans and additional information; and WHEREAS, on January 1, 2018, Eileen Wingate, authorized agent, submitted information and materials for review as required; and Power:Equipment Plus Page 2 April 23, 2019 WHEREAS, on January 14, 2019, the Planning Board accepted the application as complete for review; and WHEREAS, on January 14, 2019, the Southold Town Planning Board, pursuant to State Environmental Quality Review Act (SEQRA) 6 NYCRR, Part 617.5 (c), determined that the proposed action is a Type II Action as it falls within the following description for 6 NYCRR, Part 617.5(c)(2) replacement, rehabilitation or reconstruction of a structure or facility, in kind, on the same site, including upgrading buildings to meet building or fire codes, unless such action meets or exceeds any of the thresholds in section 617.4 of this Part. The action is for the conversion of an existing building with no footprint expansion, to include equipment repair/service/sales; and WHEREAS, on February 1, 2019, the Planning Board, pursuant to Southold Town Code §280-131 C., distributed the application to the required agencies for their comments; and WHEREAS, the proposed action is exempt from review by the Suffolk County Planning Commission (SCPC); and WHEREAS, on February 1, 2019, the Southold Town Code Enforcement officer verified that there were no open violations on the subject parcel; WHEREAS, on February 8, 2019, the Southold Town Fire Inspector reviewed, and determined that there was adequate fire protection and emergency access for the site; and WHEREAS, on February 11, 2019, a Public Hearing was held and closed; and WHEREAS, on February 11, 2019, the Architectural Review Committee reviewed the proposed project and approved it as submitted; and WHEREAS, on February 13, 2019, the Southold Town Engineer reviewed the proposed application and determined the site plan required revisions in order to meet the minimum requirements of Chapter 236 for Storm Water Management; and WHEREAS, on February 20, 2019, the Mattituck Fire District determined there was adequate fire protection for the site; and WHEREAS, on February 22, 2019, the Town of Southold Local Waterfront Revitalization Program Coordinator reviewed the proposed project and determined the project to be consistent with Southold Town LWRP policies with recommendations to the Planning Board; and WHEREAS, on February 26, 2019, Joe Morgano, owner, submitted Phase 1 and Phase 2 soil reports for the subject parcel; and Power Equipment Plus Page 3 April 23, 2019 WHEREAS, at a Work Session on March 11, 2019, the Planning Board reviewed the proposed application and required revisions to the Site Plan and ,additional information; and WHEREAS, on March 11, 2019, the Southold Town Planning Board made a finding pursuant to §280-129(C)(1) that the proposed site plan presents a proper case for requiring trees to be planted for screening or landscaping purposes, but that a suitable location for said plantings does not exist, or it is otherwise impracticable, the Planning Board permits the applicant to pay a sum of$700 in lieu of two (2) required street trees; and WHEREAS, on April 1, 2019, Eileen Wingate, authorized agent, submitted revised site plans for review; and WHEREAS, on April 1, 2019, John Condon, P.E., certified the existing sanitary system as functioning as designed; and WHEREAS, at their Work Session, held on April 8, 2019, the Southold Town Planning Board reviewed the proposed Site Plan and determined that all applicable requirements of the Site Plan Regulations, Article XXIV, §280 — Site Plan Approval of the Town of Southold were met with exception of the submission of final site plans, a revised photometric plan and payment to the Tree Fund as required; and WHEREAS, on April 9, 2019, Eileen Wingate, authorized agent, submitted a payment of $700 to the Southold Town Tree Fund to satisfy the street tree requirement; and WHEREAS, on April 9, 2019, Eileen Wingate, authorized agent, submitted final plans as required; and WHEREAS, on April 17, 2019, the Southold Town Chief Building Inspector reviewed and certified the proposed retail use as a permitted use in the Hamlet Business (HB) Zoning District; and WHEREAS, on April 18, 2019, Eileen Wingate, authorized agent, submitted revised photometric plans as required; be it therefore resolved RESOLVED, that the Southold Town Planning Board has determined that this proposed action is consistent with the policies of the Town of Southold Local Waterfront Revitalization Program; and be it further RESOLVED, that the Southold Town Planning Board approves the Site Plan with four (4) conditions, on the site plan entitled "Power Equipment Plus" prepared by John J. Condon dated August 3, 2018 and last revised April 5, 2019, and authorizes the chairman to endorse the site plan. Power Equipment Plus Page 4 April 23, 2019 Conditions 1. This site plan is for retail sale and repair of power equipment and an accessory dry storage garage; 2. The garage is accessory to the retail use and is for dry storage only; 3. The natural landscaped area in the rear of the parcel and along the south property line shall be maintained as a natural landscaped and/or vegetated buffer area as shown on the site plan, with no parking of vehicles or storage of materials permitted; 4. The 6' stockade fence along the south and southwest property lines shall be maintained in order to satisfy the transition buffer requirement. Please also note the following requirements in the Southold Town Code relating to Site Plans: 1. Any new lighting fixtures beyond those approved as part of the Lighting Plan must conform to the Code and may require Planning Board approval depending on their number, size, intensity and location. Fixtures shall be shielded so the light source is not visible from adjacent properties and roadways and shall focus and direct the light in such a manner as to contain the light and glare within property boundaries and conform to §172 of the Town Code. 2. All storm water run-off from grading, driveways and gravel areas must be contained on site. - 3. Proposed storm water run-off containment systems must be inspected by the Town Engineer at the time of installation. Please call the Southold Town Engineer prior to beginning this work. 4. Approved Site Plans are valid for eighteen months from the date of approval, within which time all proposed work must be completed, unless the Planning Board grants an extension. 5. Any changes from the Approved Site Plan shall require Planning Board approval. 6. Prior to the issuance of a Certificate of Occupancy, the Planning Board must inspect the site to ensure it is in conformity with the Approved Site Plan, and issue a final site inspection approval letter. Should the site be found not in conformance with the Approved Site Plan, no Certificate of Occupancy may be issued unless the Planning Board approves the changes to the plan. Power,Equipment Plus Page 5 April 23, 2019 4 1 ` A copy of the Approved Site Plan is enclosed for your records. One copy will also be sent to the Building Department and the Town Engineer/Highway Department. If you have any questions regarding the above, please contact this office. Respectfully, Donald J. Wilcenski Chairman Encl. cc: Building Dept. w/map Town Engineer w/map By signing this letter, the applicant acknowledges that there are Town Code requirements and conditions, including those listed above, that must be satisfied prior to the issuance of a Certificate of Occupancy. Print name: C licant/Agent Signature: Date: " C IVID APR 18 2019 Southold Town Planning Board 825 Pacif11c, Ave Matti' tuck , L light ling ayout Version 4 APPROVED BY PLANNING BOARD TOWN OF SOUTHOLD DATE - rrt Prepared By Job Name: Scale,as noted Lighting Design Disclaimer Damen Sales 825 Pacific Ave The Lighting Analysis,ezLayout,Energy Analysis and/or Visual Simulation("Lighting Design")provided by Damin Sales represents an anticipated prediction of lighting system performance Date 4/17/2019 Case: based upon design parameters and information supplied b others These design parameters and information provided b others have not been field verified b Damin Sales and therefore ace ® . . E Brunswick Avenue Mattltuck,NY P s P PP v s P P v v ■`�/-, Edison,NJ 08817 results may vary from the actual field conditions Damin Sales recommends that design parameters and other information be Feld verified to reduce variation Damin Sales neither warranties, DAMIN N SALES Filename:825 Pacific Ave-Mattltuck-Vers 4 AGI either implied or stated with regard to actual measured light levels or energy consumption levels as compared to those illustrated by the Lighting Design Damin Sales neither warranties,eithe r P 732-985-8866 Lighting Layout or stated,nor represents the appropriateness,completeness or suitability of the Lighting Design intent as compliant with any applicable regulatory code requirements Huth the exception of tho F.732-985-5521 Version 4 drawings created and submitted by Damin Sales The Lighting design is issued,in whole or in part,as advisory documents for informational purposes and is not intended for construction nor I Drawn By Aaron Boyce project's construction documentation package Images taken from Google Earth \R Filename G AMAGIMLAYOUTS\825 Pacific St-Mattltuck\825 Pacific Ave-Mattltuck-Vers 4 AGI Scale is based on Tabloid Page Sizes(11 x 17) O wn3 > � o N F, w rl 0 U 3 LU Q con I DC TOWN OF SOUTHOLD Prepared By: Job Name: Scale:as noted Lighting Design Disclaimer DATE 15 2 ED19 Damin Sales 825 Pacific Ave Date:4/17/2019 Case: The Lighting Analysis,ezLayout,Energy Analysis and/or Visual Simulat " mi Sales re resents an anticipated prediction f lighting system performance 28 Brunswick Avenue Mattituck,NY based upon design parameters and information supplied by others Th a design parameters and iniorination prow e ig, by Damm Sales and therefore act DAMIN SALE Edison'NJ 08617 results may vary from the actual field conddions Damm Sales recomm ds that design rs and other m rma old f to red variatio Damm Sales neither warranties, S Filename:825 Pacific Ave-Mattituck-Vers 4.AGI either implied or stated with regard to actual measured light levels or a rgy consumption evels a ompart hs it y ightin esign.Da in Sales neither warranties,eithe r P:732-985-8866 Lighting Layout or stated,nor represents the appropriateness,completeness or suitabil' of the Lighting Desi in ode req ments with the exception of th F:732-985-5521 Version 4 drawings created and submitted by Damin Sales.The Lighting design i oses and n not intended for construction nor I Drawn By: Aaron Boyce project's construction documentation package Images taken from Google Earth Filename*G\RABWGIMI-AYOUTS\825 Pacific Sl-Mattituck\825 Pacific Ave-Mattituck-Vers 4 AGI Scale is based on Tabloid Page Sizes(11 x 17) . . . . . . . . . . ' trm "ORTHo 4.1 W . . . . . . . . . . . . . . . . . . . . . . . . . . L . . . . . . . . . . . . . . . . . . . . . . .. .......... ....... ....... 1-0 0 C0 . . . . . . . . . . . . . . . . . . EXISTING TOWN 0)E Or SOUTH OLD 0 C: STORM DRAIN • 1= A.D.A.ACCESS RAMP '0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • SEE,DETAIL 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (3)10'DIkPPECA$TCON CRFTE LEACHING POOLS SEE DE A L6 MTA CROSSING CONTROL PANEL EXISTING TOWN . . . . . . . . . . . . OF;SOUTHOLD DRIVLVAY S I ORM DRAIN PARKING CALCULATIONS PLANTING AREA BUILDING#1 3,011 S.F. = 15 REQUIRED BASED ON RETAIL A.D.A:ACCESS.R4IMP 4'LANTJNG�7A PARKING CALCULATIONS OF 1 PER 200 S.F.OF 2%51%WAX SLOPE W1 GROSS FLOOR AREA 'GATE IX ' WARNNG SURE, w-AREA-A i . . . . . . . . . . . . . .. . . . . . . . . . . . . BUILDING#2 . . . . . . . . . . . . . . Agkj.1iMjMMJ&?,800 S.F.=3 REQUIRED BASED ON STORAGEEXT`G SIDEWALK PARKING CALCULATIONS OF 1 PER 1000 S.F. OF GROSS FLOOR AREA. . . . . . . . . . . * CONCRETE BLOCk& NEW 5'MIN.SIDEWALK GF5 . . . . . . . . .. . . STUCCO(�ARAG15 . . . . . . . . SEE DETAIL 4 TOTAL: 18 REQUIRED, 19 PROVIDEDNEW 6"CURQ C, BUIL DING#1 SEE DETAIL 5 . . . . . . —STINGASPI—T . . . . . NEW SIDEWALK A DA.ACCESS RAMP SEE DETAIL I 5L < "JIM W of . . . . . . . . . . . . . . . . . . . . . . . . . ,_-._ . . . . . . . CONCRETE APPROACH, BORDER PLANTING SEE DETAILS I AND 2 . . . . . . . . . EXISTING-LEACHING POOL- . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.D.A.ACCE SIS RAMP . . . . . . . . . 82' 1- , NEW 6 STOCKADE FENCE SEE DETAIL I Z, 1'a- NEW 6'CHAINLINK FENCE . . . . . . . . . . . . .. . . CONCRETE BLOCK& . . . . . . S TUCC 0 GARAGE BUILDING#2 . . . . . . . . . . . . . . . . . . . . . . . . . . . APUPROVED,BT . . . NSW 6'QHAINIINK FENCE. . . . .. ... . . . . . . . . . . . . . . . .. . . . . . . . P,40AR TOWN OFSOUTHOLD . . . . . . . . . . . . . . . . . . . . . . . . . . . SITE PLAN . . . . . . . . . b- Not to Scale Prepared By: Job Name: Scale as noted Lighting Design Disclaimer Damin Sales 825 Pacific Ave The Lighting Analysis,ezLayout,Energy Analysis and/or Visual Simulation(*Lighting Design")provided by Damin Sales represents an anticipated prediction of lighting system performance 28 Brunswick Avenue Mattituck,NY Date:4/17/2019 Case: based upon design parameters and inforrnation supplied by others These design parameters and information provided by others have not been field verified by Damin Sales and therefore act Edison, NJ 08817 results may vary from the actual field conditions Damin Sales recommends that design parameters and other information be field verified to reduce variation Damin Sales neither warranties, DAMIN SALES P:732-985-8866 Lighting Layout Filename:825 Pacific Ave-Mattituck-Vers 4.AGI either implied or stated with regard to actual measured light levels or energy consumption levels as compared to those illustrated by the Lighting Design Damin Sales neither warranties,eithe r or stated,nor represents the appropriateness,completeness or suitability of the Lighting Design intent as compliant with any applicable regulatory code requirements with the exception of the F: 732-985-5521 Version 4 drawings created and submitted by Damin Sales The Lighting design is issued,in whole or in part,as advisory documents for informational purposes and is not intended for construction nor I Drawn By. Aaron Boyce project's construction documentation package Images taken from Google Earth Filename G.\FZAB\AG132\LAYOUTS\825 Pacific St-Mattituck\825 Pacific Ave-Mattituck-Vers 4 AGI I Scale is based on Tabloid Page Sizes It 1 x 17) • TURF GRASS 4 , , T '0.0 0.0 0.0 0.0 0.0 0.0 '0.0 0.0 '0.0 0.0 '0.0 0.0 '0.0 0.0 0.0 '0.0 0.0 0.0 0.0 '0.0 Q,.0-: -10,0' 6: 0."031y 0.0 0.0 '0.0 0.0 0.0 0 0 /(0.0 0.0 '0.0 0 , . 4 v R D IVEWAY 0.0 0.`0 0.O 0.0 0.0 '0.0 0.0 0.0 0.0 '0.0 0.0 0.0 0.0 0.0 0.�1 ' 00 0.0 0.0 0.0 0.0 0.0 X0.0 0.1 0.1 0.1 0.1 U.1 1 sl 6 0.0 On 0 r0. o.o o.o 'a":o V S PLANTING AREA • T 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.o c.0 0.0 0.0 o.a" o.a o.o J. o.o o.o 0.1 0.2 0.3 *0. O.z�-O 1 0.1 �n:o '0.0 0!0 0. �,o o' o.o o.o . ILDING #1 p D'uAD'oQN 'bET �- o.o 'o.o 'o.o 'o.o 'o.o 'o.o '0.0 0.0 •o, ` �,o.o 'o.o 'o.o p�•D.A� 14� C�S� RAI�I� "-o.i - 0.3 '0.6 'o.9 '0.7 '0.4 0.2 '0.1LANJII�GARA o.p �'o.o '0.0 '0.0 0.0 " NS OF 1 PER 200 S.F. OF 2%%tM SLOPE W1 � . PET. wAR� INGU ,URAREA 'o.o 'o.o o:o' .o ' .o 'o.o .0 .1 'oF .o o.o n.o o.c o.o .o w A U m ' Q Q '15.0 '0.D 10.0 *0.0 '0.0 0.0 *0.0 0.0 '0.0_` 0.0 '0.0 *0.0 '0.0 '0.0 '0.0 0.1 -`0.1 0.2 0. 'o.3 '0.3 L 0.3 1.6 74.2 2.4 '0. rl {� 0 'G. '0. ] 10. '0 -0 I, 0.0 10.0 '0.0 BASED ON STORAGED - 0.0 0.1 '0.2 0.3 '0.s 0.7 E/�T'G SIDEWALK o 9 o.s '0.2 ` 0 1 0. 0.0 y. la.o ry SNS OF 1 PER 1000 S.F. /� 0 '0.0 0.0 0.U 0.;� .:? '0.U '0.0 _'0.o '0 '0.�� 0.0 0.0 '0.'0 0.0 '0.0 0.1 0.1 0.:' '0.5 '1.0 1.7 1. '3. *0 0.8 0.3 0.1 ' '0.0 , 0.0 0.0 0.0 /-'` • CONCRETE BLOCK � � NEW 5 0.0 0.0 0.0 -0.0 0.ri 'n. '� 'C. '0.^ i •n. 5 0.:' 0.0 0.0 0.0 0.0 _ - -.1 3. C V R/`y 1 -0.o 0.0 0.0 N '0.0 i S CO A 19 PROVIDED 5Q BUILDI 18 • ). i 0 '0 „ .0 ��. 1 'u."� 0. 1 � � 'r .'i ��;.0 0.0 0.0 0.0 0.0 '0. l 'o.1 0., ']_. 1 =.1 1. a '1.4 0.6 0.3 0.1 0. �i.0.0 0.0 0.0 NEW C.0 C •; 4 EXISTING ASPHALT _ Q "• ' .¢_ ;0.1'. ?. '0.1 '0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.2 '0.3 '0.6 '0. 0.: 0 C SNE�i'! SfD 1/1�ALK•o. 0.0 0 0__ o.IS`•DCA. J 0 0.0 0.0 0.0„ O.0 0.2 0 Q 0 Of` c 0.0 1 0.7 0'.6 0.5 0.3 0.2 '0.1 1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.2 0.3 '0.3 '0.3, ui _ q, 1� .� .o 'C. '0..' '0.2 '0.1 0. L i 0.0 '0.0 0.0 0:. US < 0 0.0 0.1 '1.0 '.1 '1.5 0.8 0.5 '0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.1 0. .1 0.1 0.1 0.1 '0.0 0. ,. '0.0 0.0 C. ) 0.i 0.0 '0.0 �' '0.0 '0.0 -0_ o C . (�: 0 BORDER PLANTING 1.1 Y �XI�TNG•�FACI�IGFo�OLo_1 0.1 'o.o 0.0 o.o 'o.o o.l o.l o.l o.o 'o.o o.o o.o o.o ---'a_o --"o.o- '0.0 'o.o- "C'.0 --'o.o 'o. o.o o.o o.o o.o 0\=0-.8I 0.8 0.8 0.5 0.3 '0.2 0. 1 ''.1 0.o '0.0 0.C 0.0 '0.0 r.0 0.J '0.0 'I7$Q$2''0.0 0.0 o.o 0.0 o.0 o.0" 0.o 'o.0 0.0 o.o ' 0.0 0.0 0.0 0:'� A nn NEW U STOCKADE FENCE 0.0 0.0 0 ,' 0.6 -5S 0 '1.0 0.9 1.2 '1.7 '1.6 '1.0 0.5 '0.2 0.1 '0.1 '0.0 '0.0 0.G '0.0 *0.0 0.0 0.0 *0.0 *0.0 0.0 0.0 *0.0 0.0 '0.0 0.0 0.0 "0.0 *0.0 0.0 0.0 '0.0 0.0 x *0.0 0.0 '0.0 '0.1 10.3 '0.4 S0.5 '0.7 '1.5 '2.9 '2.9 'i.3 0.5 '0. ' 0.1 0.0 0.0 0.0 *0.C '0.0 '0.0 '0.0 0.0 0.0 '0.0 0.0 0.0 ON� '0.0 '0.0 0.0 r .p FENCE yP VE 0 0.0 0.0 0.1 0.2 0� 0. '2 2--�5 *1 0.3 -(3 i 0'.o .Q.-, '0.0 0.0 0.0 '0.0 0.0 0.0 0.0 0.0 '0.0 0.0 '0.0 1 .0 0. �iabA0� .0 0.0 0.0 0.0 0.0 0.0 x .0 '0.0 o.0 0.0 0.0 0.1 '0.1 0.1 '0.0 '0.0 '0.o '0.0 0.a *b.o '0.0 0.0 '0.0 *0.c *0.0 '0.0 0.0 0.0 0.0 '0.0 0.0 '0.0 p.o 0TOI O�SO�OTO 0.0 '0.0 0.0 0.0 0.0 CONCRETE BLOCK �c C ( GARAS C .o o.o o.o o.o 'o.o o.o 'o.o �, �'�o � �: � o.o o,o 0.0 0.0 'o.o o.o 0.0 '0.0 '0.0 0.0 `0.0 'o.0 0.0 0.0 '0.0 0.0 '0.0 '0.0 '0.0 'o o b CO EARA S E; o.o o.o .q ' ' BUILDING #2 10.o 10.0 0.0 10.0 10.o '0.0 ° 70 0 o 10.0 *0.o 70.o 70.o '0.0 ' .o '0.0 0.0 '0 '0.0 0.0 '0.0 o "0 '0.0 0.o 'o o o.o o.0 *0.0 Not to Scale P Prepared By: Job Name: Scale:as noted Lighting Design Disclaimer Damin Sales 825 Pacific Ave APR 18 2 O,9 Date:4/17/2019 Case: The Lighting Analysis,ezLayout,Energy Analysis and/or Visual Simulation(-Lighting Design")provided by Damin Sales represents an anticipated prediction of lighting system performance 28 Brunswick Avenue Mattituck,NY based upon design parameters and information supplied by others These design parameters and information provided by others have not been field verified by Damin Sales and therefore act Edison,NJ 08817 results may vary from the actual field conditions Damin Sales recommends that design parameters and other information be field verified to reduce variation Damm Sales neither warranties, D A M I N SALES Filename:825 Pacific Ave-Mattituck-Vers 4.AGI either implied or stated with regard to actual measured light levels or energy consumption levels as compared to those illustrated by the Lighting Design Damin Sales neither warranties,eithe r P:732-985-8866 Lighting Layout Southold Town or stated,nor represents the appropriateness,completeness or suitability of the Lighting Design intent as compliant with any applicable regulatory code requirements with the exception of in F:732-985-5521 Version 4 drawings created and submitted by Damin Sales The Lighting design is issued,in whole or in part,as advisory documents for informational purposes and is not intended for construction nor I Planning Board Drawn By: Aaron Boyce project's construction documentation package Images taken from Google Earth Filename G\RABIAGl32\LAY0UTS\825 Pacific St-Mattituck\825 Pacific Ave-Mattituck-Vers 4.AGI Scale is based on Tabloid Page Saes(11 x 17) r n . r Luminaire Schedule Tag Symbol Qty Label Arrangement Lum. Lumens LLF Description Lum.Watts Arr.Watts Total Watts F IB 1 WPLED18Y SINGLE 2379 1.000 Wall Mount- 3000K 20.7 20.7 20.7 G EB 3 WPLED26Y SINGLE 3296 1.000 Wall Mount- 3000K 29.7 29.7 89.10001 I — 1 ALED26Y SINGLE 3296 1.000 Pole Mount- 3000K 29.7 29.7 29.7 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min Description PtSpcLr PtSpcTb Meter Type Property Line Illuminance Fc 0.01 0.04 0.00 N.A. N.A. Readings Taken At 0' 0"AFG 2 N.A. Horizontal Site Illuminance Fc 0.08 5.0 0.0 N.A. N.A. Readings Taken At 0' 0"AFG 10 10 Horizontal Target Area Illuminance Fc 0.43 5.0 0.0 N.A.---t N.A. Readings Taken At 0` 0"AFG NOTES Isoline Legend *The light loss factor(LLF)Is a product of many variables,only lamp lumen depreciation(LLD) pp (quotient) Illuminance (Fc) APPRW . has been applied to the calculated results unless otherwise noted The LLD is the result uotient ��D BY of mean lumens/Initial lumens per lamp manufacturers'specifications. Color Value p t�,�,n *Illumination values shown(In footcandles)are the predicted results for planes of calculation either 0 0 . 5 PLANNING 0Y4w9iAPW horizontal,vertical or Inclined as designated In the calculation summary Meter orientation Is normal 92 1 to the plane of calculation 2 TOWN OF SOUTHOLD *The calculated results of this lighting simulation represent an anticipated prediction of system performance. ®�� 2v' W Actual measured results may vary from the anticipated performance and are subject to means and methods which are beyond the control of Damin Sales '*Mounting height determination Is job site specific,our lighting simulations assume a mounting height `(Insertion point of the luminaire symbol)to be taken at the top of the symbol for ceiling mounted luminaires and at the bottom of the symbol for all other luminaire mounting configurationsDamin Sales luminaire and product designs are protected under U.S.and International Intellectual property laws Patents Issued or pending apply ; WS Prepared By. Job Name: Scale:N.T.S. Lighting Design Disclaimer Damin Sales 825 Pacific Ave Date:4/17/2019 Case: The Lighting Analysis,ezLayout,Energy Analysis and/or Visual Simulation("Lighting Design")provided by Damin Sales represents an anticipated prediction of lighting system performance 28 Brunswick Avenue Mattituck,NY based upon design parameters and information supplied by others These design parameters and information provided by others have not been field venfied by Damin Sales and therefore act Edison, w 08817 results may vary from the actual field conditions Damin Sales recommends that design parameters and other information be field venfied to reduce variation Damin Sales neither warranties, DAM I N SALES Filename-825 Pacific Ave-Mattituck-Vers 4 AGI either implied or stated with regard to actual measured light levels or energy consumption levels as compared to those illustrated by the Lighting Design Damin Sales neither warranties,eithe r P:732-985-8866 Lighting Layout or stated,nor represents the appropriateness,completeness or suitability of the Lighting Design intent as compliant with any applicable regulatory code requirements with the exception of th F-732-985-5521 Version 4 drawings created and submitted by Damin Sales The Lighting design is issued,in whole or in part,as advisory documents for informational purposes and is not intended for construction nor I Drawn By: Aaron Boyce project's construction documentation package Images taken from Google Earth Filename G\RAMAG132\LAY0UTS\825 Pacific St-Mattituck\825 Pacific Ave-Mattituck-Vers 4 AGI Scale is based on Tabloid Page Sizes(11 x 17) i Luminaire Location Summary Luminaire Location Summary Luminaire Location Summary LumNo Label Mounting Height LumNo Label Mounting Height LumNo Label Mounting Height 1 WPLED18Y 15 3 WPLED26Y 16 4 WPLED26Y 20 5 ALED26Y 20 7 WPLED26Y 20 NOTES: 'The light loss factor(LLF)Is a product of many variables,only lamp lumen depreciation(LLD) APPROVED �Y has been applied to the calculated results unless otherwise noted The LLD Is the result(quotient) of mean lumens/Initial lumens per lamp manufacturers'specifications A 'Illumination values shown(In footcandles)are the predicted results for planes of calculation either PLANNING W.OA� horizontal,vertical or Inclined as designated In the calculation summary.Meter orientation Is normal ii 1I�D to the plane of calculation. TOWN OF SOUM^' The calculated results of this lighting simulation represent an anticipated prediction of system performance. �r VW Actual measured results may vary from the anticipated performance and are subject � to means and methods which are beyond the control of Damin Sales. DA,G 12— 2 C)I RECEIVE 'Mounting height determination Is job site specific,our lighting simulations assume a mounting height (Insertion point of the luminaire symbol)to be taken at the top of the symbol for ceding mounted luminaires �• p and at the bottom of the symbol for all other luminaire mounting configurations �. APR 1 O 2019 'Damin Sales luminaire and product designs are protected under U.S.and International Intellectual property laws. �v SOutho Town Patents issued or pending apply Planning Board Prepared By: Job Name: Scale:N.T.S Lighting Design Disclaimer Damin Sales 825 Pacific Ave Date:4/17/2019 Case: The Lighting Analysis,ezLayout,Energy Analysis and/or Visual Simulation("Lighting Design")provided by Damin Sales represents an anticipated prediction of lighting system performance 28 Brunswick Avenue Mattituck,NY based upon design parameters and information supplied by others These design parameters and information provided by others have not been field venfied by Damin Sales and therefore act • `R' Edison,NJ 08817 results may vary from the actual field conditions Damin Sales recommends that design parameters and other information be field venfied to reduce variation Damin Sales neither warranties, D .AM'■- SALES Filename:825 Pacific Ave-Mattituck-Vers 4.AGI either implied or stated with regard to actual measured light levels or energy consumpbon levels as compared to those illustrated by the Lighting Design Damin Sales neither warranties,eithe r Pi 732-985-8866 Lighting Layout or stated,nor represents the appropriateness,completeness or suitability of the Lighting Design intent as compliant with any applicable regulatory code requirements vnth the exception of tho F:732-985-5521 Version 4 1 drawings created and submitted by Damin Sales The Lighting design is issued,in whole or in part,as advisory documents for informational purposes and is not intended for construction nor I • Drawn By: Aaron Boyce pro/ecfs construction documentation package I Images taken from Google Earth r Filename G.1RAMAGIMLAYOUTS1825 Pacific St-Mattituck\825 Pacific Ave-Matbtuck-Vers 4 AGI Scale is based on Tabloid Page Sizes(11 x 17) 51SfFtil; ` BUILDING DEPARTMENT-Electrical-in ctpr TOWN OF SOUTH OL [� �(, �, rFFY ' Town Hall Annex - 54375 Main Roa O Box 1179 Southold, New York 1197 59 -fflI��oo lFf Telephone (631) 765-1802 - FAX{631) 7A5h2 2019 roaer:richertMtown 86Uth6ld.'hy:us .__ . . BU1DDTG DEPT, APPLICATION FOR ELECTRICAL INSPECTION '0'?'90LD REQUESTED BY: _7_144=C)T-`f ��_� 0 Date: 4 L7 -- Company Name: STR C ELECT /c/1 _ _-- Name: License No.: /14 — &D email: FE - Andress: 5' (� RJ/ 14VE _L S r` f �vJv� _ 1��1 Phone No.- 3.1.. JOB SITE INFORMATION: (All Information Required) Name: gH( 4wcl tfo/ �ti LLG Address: v_ G f K C Cross Street: Phone No.: Bldg.Permit#: �3.7_ email: - Tax Map District: 1000 Section: Block: L Lot:1 (� B IEF DESCRIPTION OF WORK(Pleas Print Clearly) 61pn4,7 td l CPO V-6�-7 r o 4,7 Circle All That Apply: Is job ready for inspection?: YES 1_O Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service-Size 1 Ph 3 Ph Size: A # Meters__ __ Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected -Underground - Overhead #:Underg�isund Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: - - PAYMENT'DUE WITH APPLICATION kec gq'5s-k- 82-Request for Inspection FormAs �� `. Telephone(631)765-1802 Town Hall Annex a'�� � } 54375 Main Road "".. Fax(631)765-9502 P.O.Box 1179 Southold, NY 11971-0959 ° BUILDING DEPARTMENT NOTICE-OF-UTILIZATION OF TRUSS_TYPE-;CONSTRU-'CTI.QN.'PREMENGINEERED WOOD CONSTRUCTION-AND/OR_TIMBER CONSTRUCTION,— Date, 1 Owner: x Location of Property:. L t Please take notice that the (check applicable line): New commercial or residential structure Addition to existing commercial or residential structure -- r Rehabilitation to an existing commercial or residential structure to be constructed or performed at the subject property reference above will utilize (check applicable line): Truss type construction (TT) Pre-engineered wood construction (PW) Timber construction (TC) in the following location(s) (check applicable line)'; - -. Floor framing, including girders and beams (F) Roof framing (R) Flo and roof framing (FR) Signature: Name (person submitting t ' form): __ .__ Capacity(check applicable line): Owner Owner representative - TrussReg15.docx Effective 1/1/2015 - - - 617 DIA STARMEOW - REFLECTIVE WHITE REFLECTIVE RED i PANTONE #187 t% f _ f i i If f ; rI It i t� ii t r• --- — — — --- , — — "— — — — ---- I251 — -— — , { ' : s The construction type STRQ.�E� designation shall be q19 &AIJ99' 6611,17!' AAIV"or iiV77 to indicate the construction classification of the structure under DES10,NATION, fil- $TR0 TURA►L section 602 of the BCNYS CO P' ► E ITS THAT' ARE .0 TRUSS TYPE. 09NSTR.U=CTI•Ca;N 'APP FLOOR FRAMING, INCLUDING R. ■ GIRDERS AND BEAMS ■ ROOF FRA111fIXG i - ° . a'• `' ' 'f ccFR»,FLOOR AI+1.D ROOF FRAMING STANDARDS AND CODES Estimate for Renovation of 825 Pacific Street D ECROVE D MAY 2 0 2019 11UMDU "Dur', Building Cost TOWN of souTHui-LD Interior Renovations $125,000.00 Exterior Renovations $60,000.00 Total: $185,000.00 A.D.A. Compliant Renovations Accessible Ramp and Sidewalk $12,000.00 Front Entry $15,000.00 Bathroom Renovation $6,000.00 Accessible Counter $1,200.00 Total: $34,200.00 Site Work Curbing and Sidewalks $45,000.00 Drainage and Grading $35,000.00 Landscaping $14,500.00 Total: $94,500.00 -c 0 1 All exterior lighting Installed,replaced or APPRO ED AS NOT D repaired shall confornn DATE: 5 B.P. 3 to Chapter 172 FEE: 13 T BY: of the Town Code NOTIFY BUILDING DEPARTMENT AT 765-1802 -8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE PLUMBER CERTIFICATION 2. ROUGH'- FRAMING & PLUMBING' 3. INSULATION ONLEAD CONTENT BEFORE 4. FINAL - CONSTRUCTION MUST CERTIFICATE OFOCCUPANG, BE COMPLETE FOR C 0. SOLDER USED IN WATER ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW SURnYSYSTEM CANNOT YORK STATE. NOT RESPONSIBLE FOR EXCEED2110 OF I` LEAD. DESIGN OR CONSTRUCTION ERRORS. ,k G COMPLY WITH ALL CODES OF 1:�JMBIt0 WASTE NEW YORK STATE & TOWN CODES WET--8 LINES NEED G�BEFORE COVERING AS REQUIRED AND CONDITIONS OF -. SOUTHOLD TOWN PLANNING BOARD en 88641 10@49WUIRUSM TRUSS PI.ACARDING REQUIRED OCCUPANCY OR USE IS UNLAWFUL ELECTRICAL INSPECTION REQUIRED WITHOUT CERTIFICATE OF OCCUPANCY r RL,INt.1 DRAINAGE INSPECTIONS ARE REQUIRED ; REO' �11 BEFORE Contact TOS Engineering at 765-1560 before _ ���� Backfill,OR Provide Engineer's Certification , '` that the drainage has been Installed to Code. ' APPLICATION FOR BUILDING SCTM # 1000 - 141 - 04 - 11 POWER EQUIPMENT PLUS 825 PACIFIC STREET MATTITUCK, NY 11952 BUILDING #1 - 3,011 S.F. RETAIL SALES OCCUPANCY LIMIT 50 PERSONS BUILDING #2 - 2,800 S.F. STORAGE LOT AREA - 1.136 ACRES LOT COVERAGE - 5811 S.F. OR 11.73% LANDSCAPE COVERAGE - 34% SOIL BORING RESULTS HAMLET BUSINESS (HB) ZONE NORTH SURVEY PREPARED BY PECONIC SURVEYORS, PC DATED AUG. 3, 2018 SANDY LOAM, ORGANIC MATTER i.a: .ti.`� i4•i�.. EXISTING TOWN 25. : CONDITIONS y�� . r 7;��='�V`- ' F SOUTHOLD SAND, STORM DRAIN SOME GRAVEL THIS :"3ITE PLAN IS FOR RETAIL AND AN ACCESSORY DRY } '• �. . ACCESS RAMP STORAGE GARAGE SEE DETAIL 2 � �. THE GARAGE IS ACCESSORY TO THE RETAIL USE AND IS FOR DRY STORAGE ONLY —79'--- ( SAND __ ---f— °'� EACHING POOLS THE NATURAL LA ST CONCRETE IWDSCAPED AREA IN THE REAR OF THE — _ _ _- �'� + �— 52 8 ,QS' Q TURF GRASS SEE DETAIL 6 PARCEL AND ALONG THE SOUTH PROPERTY LINE SHALL WATERzo o BE MAINTAINED AS A NATURAL LANDSCAPED AND/OR \ MTA CROSSING CONTROL PANEL ll , - TURF GRASSJ i EXISTING TOWN VEGETATED BUFFER AREA AS SHOWN ON THE SITE BORING DONE BY: LONG ISLAND ANALYTICAL — N F SOUTHOLD PLAN„ WITH NO PARKING OF VEHICLES OR STORAGE OF LABORATORIES INC. DRIVEWAY STORM DRAIN MATERIALS PERMITTED DATE OF BORING: MAY 31,2018 BORING DIAMETER: 2 INCHES ( - PLANTING AREA BORING#: SB-3 WELL CASTING: N/A \ I M 6� THE STOCKADE FENCE ALONG THE SOUTH AND SOUTHWEST PROPERTY LINES MUST BE MAINTAINED IN _ I01 ORDER TO SATISFY THE TRANSITION BUFFER � A.D A. ACCESS RAMP PLANTING ARE W/ REQUIREMENT ��, 2% MAX. SLOPE ; GATE \ s DET. WARNING SURF. AREA A rr s ,1_ PARKING CALCULATIONS LL EXTG SIDEWALK z __ 1 I U BUILDING #1 3,011 S.F. = 15 REQUIRED BASED ON RETAILz 5' 5' 7'- PARKING CALCULATIONS OF 1 PER 200 S.F. OF e/ Y REMOVE EXISTING PLAN GROSS FLOOR AREA ti6 ( RETAIL o a NSTALL 5i MIN. SIDEWALK SEE DETAIL 4- 19 28.3' -- t BUILDING#1 NEW 6" CURB BUILDING #2 5 = REQUIRED BASED ON STORAGE QPM EXISTING I SEE DETAIL 5 2,800 S.F. 3 R QU G5 I ` A.D.A. ACCESS RAMP PARKING CALCULATIONS OF 1 PER 1000 S.F. OF �� �QP��\� EW SIDEWALK SEE DETAIL 1 GROSS FLOOR AREA � - -50.1 a C) 0 TOTAL: 18 REQUIRED, 19 PROVIDED �� ' "' I M a o CONCRETE APPROACH N BORDER PLANTING i SEE DETAILS 1 AND 2 EXISTING LEACHING POOL L \ . in DRAINAGE CALCULATIONS - AREA A 9p i -- -- --- -- - 17s.s2' N- — - - - - — A.D.A. ACCESS RAMP NEW 6'STOCKADE FENCE SEE DETAIL 1 SQUARE FOOTAGE - AREA A 15,400 ROOF AREA - 50.1 x 60.1 = 3,011 771 UNDERSIGNS PURSUANT LD TOWN CODE SWITON AREA - ROOF = 12,389 SQ. FT. 2M131(0,32M131(0,ACKNOWLEDGES THE THAT THE E GOND cpNDmDNs of THE SITE PLAN 12,381) S.F. x2" = 2,064.84:1.zzm4AREACCEPTED(SE-ECo THE ROVAL SET FORTH IN "SOLUTION OF APPROVAL DATED 10' LEACHING POOL NEW 6'CHAINLINK FENCE NDMONSONP.ESOLUTIO.N). Tr x 5' = 76.5 P .P NAME -./vf{- f>� 100 x 10' = 765 C.F. co 2064.8 / 765 = 2.69'9 1. IloxlzED sicNATuxT TITLE DATE REQUIRES (3)100 x 10' POOLS APPROVED BY , ACCESSORY DRY o TORN OF SOUITHOLD PLANNING BOAM w STORAGE GARAGE Q AW'FRSON N BUILDING#2 DALE Aa17: Ttx awed elt d'rael �eot�'^� n rslid ter>< reeft tsom tie dlste of �nova!sa p ear scrkiot,� 2t."-132A.pftiod of d ,r'bfer�a(i>;)NEW V CHAINLINK FENCE —70 .6 RECEIVED APR 9 2019 Sout of Town Planning Board 'gy `� ' :� 684, c DATE SUBMITTED: . SITE PLAN DEC. 19, 2018 SCALE: REVISIONS: Condon Engineering, Pill = 201_011 MAR. 27, 2019 1755 S i gs bee Road POWER EQUIPMENT PLUS DWG. No. APR. 5, 2019 IVIattltuC�c, IVY 11952 825 PACIFIC STREET MATTITUCK, NY 11952 100.01 PLANT LIST QTY. BOTANICAL NAME COMMON NAME SIZE SPACING CODE TREE, 3 Liquidambar styraciflua Sweet Gum 2:" - 21" CAL. AS SHOWN SGM 3 Gleditsia triacanthos Honey Locust 2" - 2i" CAL. 30' O.C. HLT SHRUBS 35 Prunus Laurocerasus Skip Laurel 5' - 6' HT. 8' O.C. SKL 32 Juniperus sabina 'Tam.' Tam Juniper 5 GAL. 6' O.C. JUN 7 Miscanthus sinensis Maiden Grass 5 GAL. 5' O.C. MGS 8 Ilex glabra Inkberry 3011 - 36" HT. 4' 0.C. INK 11 JUN 12 Ilex glabra Inkberry 2411 - 30" HT. 3' 0.C. INK 7JU 3 MGS GROUND COVER 30 AJ 90 Ajuga Ajuga 4" POT. 12" O.C. AJU HLT 30 AJU BEST MANAGEMENT PRACTICES FOR LWRP 1 SG USE NATIVE, DROUGHT-TOLERANT PLANTS IN LANDSCAPING C TURF PASS 1 HLT 14 J U . i,/ TURF GRASS USE OF ORGANIC FERTILIZERS WHERE THE ., , ./ • i• RAINGARDEN 1 MGS �.__.. _ WATER-SOLUBLE NITROGEN IS NO MORE THAN 20% OF • , -, � DRIVEWAY .;/���NGARbE A THE TOTAL NITROGEN IN THE MIXTURE A MAXIMUM OF 1LB. OF NITROGEN PER 1 ,000 SQUARE 0 FEET IN ANY ONE APPLICATION, WITH A CUMULATIVE 0 1 HLT APPLICATION OF NO MORE THAN 2LBS. PER 1 ,000 SQUARE FEET PER YEAR 0 35 SKL O O GATE THE APPLICATION OF FERTILIZER PRODUCTS 0 15 AJU CONTAINING NITROGENIF- , PHOSPHORUS, OR POTASSIUM 0 ��- IS PROHIBITED BETWEEN NOVEMBER 1 STAND APRIL 1 ST 0 0 0 00 O O INK 00 00 RETAIL 1 SG 0 0 O BUILDING #1 5 AJU 00 EXISTING ASPHALT O C O } Q W W 1 SGM a NEW 6' STOCKADE FENCE 12 INK NEW 6' CHAINLINK FENCE APPROVED BY TURF GRASS W/ ACCESSORY DRY PLANNING 9OAnD NATURAL LANDSCAPE BUFFER STORAGE GARAGE TOWN OF SOUTHOLD BUILDING #2 DATE (5 1'2_`?_O 19 (NEW 6' CHAINLINK FENCE y,�."i' ��.a RYAµ,�f.,'.i , '`•r ,.. RECEIVED . � 20 APIR 1:560ffi_o_j_dTown 0 Planning Board �' � �:• �� DATE SUBMITTED: LANDSCAPE PLAN- DEC. 19, 2018 SCALE: REVISIONS: Emp- ineerinu = 20'-0" MAR. 2712019 1755 Sigsbee Road- POWER EQUIPMENT PLUS DWG. NO. attituck, NY 11952 825 PACIFIC STREET MATTITUCK, NY 11952 100.02 SINGLE DIRECTION RAMP 2% MAX SLOPE W/ DETECTABLE WARNING SURFACE SINGLE DIRECTION RAMP 2% MAX SLOPE W/ DETECTABLE WARNING SURFACE 301 .� A RADIUS VARIES ° d v SEE PLANS p +++++++ ° EX0A SOON JOINT ° n d +++++++ J + ++++4 G p p + + + �►/ + + + c d ++++++4 ° ., n ++ + + C V d TRAF=FIC CURB ++++`+` ° d + + + + d ° +++ ++ +++(VARY CURB EXPOSURE + + + n p IE Z11n ° ON-SITE AS NECESSARY) SEE PLANS c d ° CO N'T'ROL JOINT 4 d VALLEY GUTTERZ. d d ' ° ° ° d WITH STANDARD CURB " STANDARD CURB ° ° d ° ° SEE DETAIL 3 " SEE DETAIL 3 �° ° ° n u d d ° MULTI DIRECTION RAMP 2% MAX SLOPE W/ DETECTABLE WARNING SURFACE A VALLEY GUTTER WITH STANDARD CURB SEE DETAIL 4 � COMMERCIAL CONCRETE APPROACH DETAIL 2 CORNER A.D.A. ACCESSIBLE RAMP CB ®AD SIDEWALK UR SIDEWALK / -GRASS--- ----------- - 5 --------- --GRASS--- --------------- - --- - -- 51 MIN . MIN . " x18" CURB CONTROL JOINT GRASS MOW STRIP OADWAY SURFACE 1.5% MAX I_I . ` •. ; : *. .. ; II! -;II -I_i__. .III li II_ it 15 ____ _ ___-- . ...-„ .;., , �. ,�, � � ..I! .. _ =.:Ili, _ _.,Ii,..;, _ .�; __�-II'__;II �..,..IIL.-. � •. . : . : il,- HOT MIX ASPHALT17 _ - - - - ;r �: ... (11:.:..:111. .., .�r III- i_ 2” TOP COURSE .. O T 4... �r -,�i===iil==llL- 2" TOPICOURSEL 2.5" BINDER COURSE NEW CORPORATE SIGNAGE ------------- ------------------------------------------------ EXISTING WINDOW PLUS r _— NEW CANVAS AWNING W/ALUMINUM ARMATURE r____-----i ---- �___-_ f --. �_________ I i 1 1 IF ---------------- i i I I i , PROPOSED NORTH ELEVATION- NEW CORPORATE SIGNAGE L-------------- - -- -------------- ---- ------- ------------------------- - --- - ------- -- -- -- ---- - -- - ----- -- - - - ---- -- ------- �' f::.:. . . --- -- ---------- --- ---- --- -- ---- - - XISTING WINDOW PLUS I NEW CANVAS AWNINGW/ALUMINUM ARMATURE EXTERIOR COLORS ----------------------------- I - HARD I E PLANK BRAND CLAPBOARD STYLE 1 I 825 PACIFIC 1 1 01 - 41 "IRONGRAY" 4' - ROOF "LIGHT MIST" I i I i i CANVAS AWNING SUNBRELLA BRAND 1 I I E i "GRAY" 1 ! I € 1 i 1 APPEOVED B ----- ----------- PLANNING BOARD TOWN OF SOUTHOLD DATE cl PROPOSED FRONT ELEVATION R N APR ZDi9 fE � • �Soutiiobcl Town Planning Board DATE SUBMITTED: DEC. 19, 2018 SCALE: REVISIONS: Engineerinu , if _ 1_ 11 4 1 MAR. 2712019 � 1755 SISb�� RoadPOWER EQUIPMENT PLUS I DWG. No. attituck, NY 11952 825 PACIFIC STREET MATTITUCK, NY 11952 300 .01 -----------------------------------------_---------------------------------------------- NEW ___________________________________________- NEW HARDIE PLANK SIDING - PAINTED CORPORATE COLORS I NEW 4'-8"x 2'-4"AWNING WINDOW-- - I _ _ EW CANVAS AWNING �- ------------------ L-------------------' ------------------ O E SOUTH ELEVATION- NEW HARDIE PLANK SIDING PAINTED CORPORATE COLORS NEW 4'-8"x 2'-4"AWNING WINDOW - A A - APPP OVER BY ------ --�, to 10-- - -- — -- PLANNING BOARD TOWN OF SOUTHOLD ------------- -- ------- ---------- - --- DATE '512 2_o I �l .Rf11tr� 'g V.i' }�•gig;h PROPOSED REAR ELEVATION , ,a: `a RECEIVED ���� tom•-w.Ii. APR 12019 �� % 1684 Southold Town 5 Planning Boards »" �"" �" DATE SUBMITTED: DEC. 19, 2018 SCALE: Condon Emv-aineerin$g , .C . �„ _ ,_ „REVISIONS: 4 MAR. 2712019 1755 Sigsbee Road DWG. No. POWER EQUIPMENT PLUS attitu c Y 11952 825 PACIFIC STREET MATTITUCK, NY 11952 300 .02 APP ICATION FOR BUI DING P R, MI FTM # 1000 - 141 - 04 - 11 POWER EQUIPMENT PLUS 825 PACIFIC STREET MATTITUCK N UILDING #1 •- 3,011 S.F. Y 11952 RETAIL SALES OCCUPANCY LIMIT 50 PERSONS BUILDING #2 .- 2,800 S.F. STORAGE LOT AREA - 1 .136 ACRES LOT COVERAGE - 5811 S.F. OR 11 .73% LANDSCAPE COVERAGE - 34% SOIL BORING RESULTS HAMLET BUSINESS (HB) ZONE NORTH SURVEY PREPARED BY PECONIC SURVEYORS, PC DATED AUG. 3, 2018 1 SANDY LOAM, ORGANIC MATTER t; • a.;.. EXISTING TOWN CONDITIONS °n`�'�~rwY '° `' F SOUTHOLD Y° 'ti SAND, SOME GRAVEL STORM DRAIN THIS SITE PLAN IS FOR RETAIL AND AN ACCESSORY DRY 190 STORAGE GARAGE ��_����� �`=��; A.D.A. ACCESS RAMP : , EE DETAIL 2 THE GARAGE IS ACCESSORY TO THE RETAIL USE AND IS00 FOR DRY STORAGE ONLY ��. _ --�— (3) 10 DIA. PRECAST CONCRETE THE NATURAL LANDSCAPED AREA IN THE REAR OF THE SAND ` , 30 ,o EACHING POOLS =52.8'_--- 11 �� TURFGRASS J SEE DETAIL 6 PARCEL AND ALONG THE SOUTH PROPERTY LINE SHALL WATER ° o E MAINTAINED AS A NATURAL LANDSCAPED AND/OR MTA CROSSING CONTROL PANEL ll _ B TURF GRASS J o EXISTING TOWN VEGETATED BUFFER AREA AS SHOWN ON THE SITE BORING DONE BY: LONG ISLAND ANALYTICAL - — N %� � F SOUTHOLD PLAN, WITH NO PARKING OF VEHICLES OR STORAGE OF LABORATORIES INC. / ;� DRIVEWAY STORM DRAIN MATERIALS PERMITTED BORING OF BORING: MAY 31, 2018 BORING DIAMETER: 2 INCHES / PLANTING AREA ; BORING#: SB-3 THE 6' STOCKADE FENCE ALONG THE SOUTH AND WELL CASTING: N/A % SOUTHWEST PROPERTY LINES MUST BE MAINTAINED IN ORDER TO SATISFY THE TRANSITION BUFFER , AA).-A-ACCESS RAMP PLANTING ARA REQUIREMENTI 2% MAX. SLOPE W/ � GATE �`, s DET. WARNING SURF. AREA A o0 ,1, 3 PARKING CALCULATIONS % ( T D EXT G SIDEWALK = v BUILDING #1 3,011 S.F. = 15 REQUIRED BASED ON RETAILti z 5' -5'- -7'- PARKING CALCULATIONS OF 1 PER 200 S.F. OF g� � REMOVE EXISTING PLAN tiI RETAIL o GROSS FLOOR AREA a NSTALL 5' MIN. SIDEWALK /' ( C° SEE DEITAIL 4 28.3' BUILDING #1 -- -- ' NEW 6" CURB BUILDING #2 SEE TAIL 5 2,800 S.F. = 3 REQUIRED BASED ON STORAGE j- �SeP EXISTING ASPHALT --A � S RAMP PARKING CALCULATIONS OF 1 PER 1000 S.F. OF Z �� ( EW SIDEWALK � g� � AQP �, SEE DETAIL 1 GROSS FLOOR AREA -- 50.1 ----- ----+ Lj >- � co TOTAL. 18 REQUIRED, 19 PROVIDED o i CONCRETE APPROACH cli N 0BORDER PLANTING 1 SEE DETAILS 1 AND 2 EXISTING LEACHING POOL "I C DRAINAGE CALCULATIONS - AREA A 9 cq ----- Tic l�S. .p - -- - - ----- - -- ---178.82'------------- N - ----- -- -- - ---- --A-D 7�ACCESS RAMP - -- NEW 6'STOCKADE FENCE �� SEE DETAIL 1 SQUARE FOOTAGE - AREA A 15,400 / % ROOF AREA - 50.1 x 60.1 = 3,011 AREA A - ROOF = 12,389 SQ. FT. 12,389 S.F. x2" = 2,064.8 ' 10' LEACHING; POOL NEW 6'CHAINLINK FENCE rrx52 = 76.5 •� i 100 x 10' = 765 C.F. co 2064.8 / 765 := 2.699 `, REQUIRES (3)100 x 10' POOLS ACCESSORY DRY w STORAGE GARAGE CD N BUIILDING#2 1 NEW 6'CHAINLINK FENCE '1i Y � - —185 14 -- --------------- -------- ---- 'i� `- , 051684 DATE SUBMITTED:DEC. 19 2018 SITE PLANSCALE.. Condon Engineering , P C i = 2REVISIONS: 201-011 MAR. 2712019 1755 Sigsbee Road DWG. NO. APR. 5, 2019 POWER EQUIPMENT PLUS , Mattituck, NY 11952 825 PACIFIC STREET MATTITUCK, NY 11952 100.01 PLANT LIST QTY. BOTANICAL NAME COMMON NAME SIZE SPACING CODE TREES_ 3 Liquidambar styraciflua Sweet Gum 2" - 2"' CAL. AS SHOWN SGM 3 Gleditsia triacanthos Honey Locust 2" - 22" CAL. 30' O.C. HLT SHRUBS 35 Prunus Laurocerasus Skip Laurel 5' - 6' HT. 8' O.C. SKL 32 Juniperus sabina 'Tam.' Tam Juniper 5 GAL. 6' 0.C. JUN 7 Miscanthus sinensis Maiden Grass 5 GAL. 5' O.C. MGS 8 Ilex glabra Inkberry 3011 - 36" HT. 4' O.C. INK 1 JUN 12 Ilex glabra Inkberry 2411 - 30" HT. 3' O.C. INK 7JU 3 MGS GROUND COVER 30 AJ 90 Ajuga Ajuga 4" POT. 12" O.C. AJU HLT 30 AJU BEST MANAGEMENT PRACTICES FOR LWRP 1 SG USE NATIVE, DROUGHT-TOLERANT PLANTS IN TURF BASS - - HLT LANDSCAPING 14 J U - _ TURF GRASS USE OF ORGANIC FERTILIZERS WHERE THE ! / / RAIN GARDEN i 1 DRIVEWAY i,ij / RAIN GARDE MGS WATER-SOLUBLE NITROGEN IS NO MORE THAN 20% OF _ - / / \ THE TOTAL NITROGEN IN THE MIXTURE A MAXIMUM OF 1 LB. OF NITROGEN PER 1 ,000 SQUARE PLICATION WITH A CUMULATIVE O L FEET IN ANY ONE AP O � APPLICATION OF NO MORE THAN 2LBS. PER 1,000 SQUARE FEET PER YEAR 0 0 GATE 5 AJU ! THE APPLICATION OF FERTILIZER PRODUCTS 35 SK O � CONTAINING NITROGEN, PHOSPHORUS, OR POTASSIUMLL IS PROHIIBITED BETWEEN NOVEMBER 1ST AND APRIL 1ST O � 8. INK O O RETAIL ISG 0 . 5 AJU 0 0 BUILDING #1 0 O EXISTING ASPHALT J O O } QQ W > 1 SGM W F- Q NEW 6'STOCKADE FENCE 12 INK NEW 6'CHAINLINK FENCE TURF GRASS W/ ACCESSORY DRY NATURAL LANDSCAPE BUFFER STORAGE GARAGE BUILDING #2 NEW 6'CHAINLINK FENCE ------------ t % DATE SUBMITTED: LANDSCAPE PLAN- DEC. 19, 2018 SCALE: REVISIONS: Condon Engineering , P .C . ill = 201-011 MAR. 27, 2019 1755 Sigsbee Road POWER EQUIPMENT PLUS DWG. No. , Mattituck, NY 11952 825 PACIFIC STREET MATTITUCK, NY 11952 100.02 SINGLE: DIRECTION RAMP 2% MAX SLOPE W/ DETECTABLE WARNING SURFACE SINGLE DIRECTION RAMP 2% MAX SLOPE W/ DETECTABLE WARNING SURFACE 30' i A - RADIUS VARIES + + + EXPA SIONJOINT + + + SEE PLANS + + + + + + + + + + + + + + + + + + + + + + + + + +++++++ I+ + + + + + TRAFFIC CURB + + + + + + + + . + (VARY CURB EXPOSURE + + ++ + + ON-SITE AS NECESSARY) � + + + ,•.;+:'+` RADIUS VARIES CONTROL JOINT SEE PLANS VALLEY GUTTER *' •' WITH STANDARD CURB **'*•`**'+'' s ♦* y STANDARD CURB SEE DETAIL 3 SEE DETAIL 3 MULTI DIRECTION RAMP 2% MAX SLOPE W/ DETECTABLE WARNING SURFACE A VALLEY GUTTER WITH STANDARD CURB SEE DETAIL 4 � COMMERCIAL CONCRETE APPROACH DETAIL 2 CORNER A.D.A. ACCESSIBLE RAMP SIDEWALK CURB,, :ROAD SIDEWALK /----GRASS--i 5 -- -- ------GRASS- - ---! -- ----- ----5� - -- -- --! MIN . MIN . "x18" CURB CONTROL JOINT • GRASS MOW STRIP -ROADWAY SURFACE 1 1.5% MAX 50/0 M HOT MIX ASPHALT �,. . . .. .. . .. ; •• -• . . .: - d_ 2 TOP COURSE •. • � � • •4• -� HOT MIX ASPHALT �-�� 2.5" BINDER COURSE 11 • 2 TOP COURSE 2.5" BINDER COURSE 4 MIN. CRUSHED STONE .tr. -6" x 6" 10 GA WIRE MESH a• 411 MIN. CRUSHED STONE ; . . 4 SIDEWALK DETAIL a �* SCALE: =1'-0" "° •,, f`tY. •,�et.• SECTION A: CONCRETE APPROACH DETAIL 3 51684. �_�YLL , r DATE SUBMITTED: DEC. 19, 2018 SCALE: REVISIONS: Condon Engineering , P.C . 111 - 11-011 MAR. 2712019 4 POWER EQUIPMENT PLUS 1755 Sigsbee Road DWG. No. 1lllattituck, NY 11952 825 PACIFIC STREET MATTITUCK, NY 11952 100-03 24" DIA. CASTING AND SURFACE INLET COVER 6" x 18" POURED CONCRETE CURB ON CRUSHED STONE BASE 10' DIA. x 5' DEEP LEACHING POOL HOT MIX ASPHALT 6" 2" TOP COURSE ® ® ® ® ® ® ® ® ® 2.5" BINDER COURSE ® ® ® ® ® ® - t c� —III—III 00 a a II III T MIN. CRUSHED STONE jl 12" DIA DRAINAGE PIPE 5 CURB DETAIL 6 10' DRYWELL DETAIL SCALE: V=V-0" .C4N ts 1:a � " a DATE SUBMITTED: • DEC. 19, 2018 SCALE: REVISIONS: Condon Engineering , P .C . 111 - 11-011- _ - 4 MAR. 27, 2019 1755 Sigsbee Road POWER EQUIPMENT PLUS DWG. No. Mattituck, NY 11952 825 PACIFIC STREET MATTITUCK, NY 11952 100.04 54"x 9Z'PSL HEADER EMERGENCY EXIT LIGHT NEW&OVERHEAD DOOR SNOTE : NEW 4"METAL FRAME WALL J EMPLOYEE ENTRANCE W/PLASTERBOARD 1 . CONSTRUCTION TYPE IS TYPE 213 2. ALL BATHROOMS ARE EXISTING 3. BUIL ING -ALREADY CONDITIONED STORAGE REPAIRS ,AND NO ALTE TIONS TO ENERGY CODE NEW 4"METAL FRAME WALL 701.5 SQ. FT. 507 SQ. FT. 4. R-21 BATT. INSULATION TO BE INSTALLED W/PLASTERBOARD HERE TING FENESTRATION HAS BEEN REMOVED EXISTING OVERHEAD DOOR S.D./C.O. 00 to IRE EXTINGUISHER C) C) PALLET RACKS ri ((2)2"x 0"HDR. ❑ -------- i I XT'G EMP. R II Y DISPLAY TMERGENCY(EXIT LIGHT -2'- 0 - -7" - JQ II o o > EXTG LOFT AREA— ICC/ANSI A117.1 - w FOR STORAGE I I I C . RESTROO W II r U I I NEW INTERIOR ENT4NCE 7-9"�1 II , o I " �x coed 10 I FLOOR DISPLAY AREA NEW CURTAIN WALL I I i 5'-0"TURNING RADIUS I V / Q 1 -F 16 0V- s I I '( Q Its CC ANSI sl I -A-fj�ACCESSIBLE I I , I ar,Qa COUNTER AREA I I } ALE I I o �D 15 SBC- g SALES FLOOR I I N 1,440 SQ. FT. � II II BOILER ROOM I I (EXTG HVAC TO REMAIN) COUNTER AREA EXT'G MASONRY BLOCK WALL COUNTER AREA j j (MIN. 1 HR.RATING) AND DISPLAY I I II II II II II I I IRE EXTINGUISHER _ II II II PARTS AND RENTAL AREA I I NEW 4"METAL FRAME WALL I I W/PL�4STERBOARD NEW ENTRANCE II DISPLAY DISPLAY "CURB 2 , —/ -21—/ I S.D./C.O. I - FLUSH CURB "--EMERGENCY EXIT LIGHT FILL IN EXISTING WINDOW CONCRETE SIDEWALK AND DOOR OPENINGS •� L N. ICC/ANSI A117.1 u.fss . .- -... •.: lO. t i <" — PROPOSED FFLOOR PN ACCESSIBLE RAMP 2%MAX.SLOPE SURFACE AT GRADE � ��"�- �* Q5`�j•g� WITH PARKING LOT �t DATE', DETECTABLE ' BMITTED: WARNING SURFACE DEC. 19, 2u 8 SCALE: Condon ineerinP .C . 111 - 11-011 REVISIONS: g _ _ 4 MAR. 27, 2019, APR.15, 2019 1755 S i gs bee Road POWER EQUIPMENT PLUS DWG. No. APR. 26, 2019, MAY '15, 2919 Mattituc Nl( 11952 MAY 21, 2019 825 PACIFIC STREET MATTITUCK, NY 11952 200.0 REMOVE EXISTING WINDOW REMOVE CONCRETE BLOCK REMOVE EXISTING WINDOW REMOVE EXISTING WINDOW TO BE REPLACED WITH TRANSOM AND EXISTING WINDOW TO BE REPLACED WITH TRANSOM TO BE REPLACED WITH TRANSOM FOR NEW ROLL-UP DOOR Ir-------- --------�1 '' .' - _ ' 1 1 I 1 1 1 I I 1 I I 1 I 1 I I I I I I I I DEMO EXISTING LOFT O � Z� I 3 I z � 1 i X0 ' W w W U I gI 00- -----------T-------------------------------------------i-- -------- W Of Ir w 1 i I m 1 1-----------y O ~ i L-----------i I 1 1 I 1 --------------DEMO EXISTING STAIRCASE I I 1 I I 4________--_.1 I I 1 I y �.I __.1__T1 __r1__ _____--____ i_______________________________ ___________ DEMO EXISTING STAIRCASE TO BE FILLED WITH SAND ---------- EXISTING BATHROOM • I I I 1 1 1 1 1 1 I I AND 4" CRUSHED STONE I I II II I I L_______________________________ -------------------------------- I I o Y EXISTING BATHROOM U 1 � D O 1 I DEMO EXISTING LOFT Z w ------------------------------------------ I I I - F------------------------------- I U) Z I ; ; o I II WU i EXISTING BATHROOM Wo of w I I I J 1 II J I II U- I I I W i II O '�....� . .•s• E'— .y EXISTING BOILEROOM Mf 1 1 �' f � '•j U Og I Z Of 11 I I i U)Z W _ I I w O ~ 3 , ; W D J J 1 I _______________________________________ __________________________________ _______________________________________ zzzzz --- --- r O f—' I M14 "S FIRST FLOORDEMO �� A'f SUBMITTED: DEC. -I,," 18 SCALE: REVISION,• Condon Engineering , P .C . 111 - 11-011 MAR. 27, 2019 1755 S i gs bee Road 4 APR. 5, 2019 POWER EQUIPMENT PLUS �W�. No. � Matt.�tuck, NY 11952 APR. 26, 2019 825 PACIFIC STREET MATTITUCK, NY 11952 200.02 1 Na � .t Q NEW CORPORATE SIGNAGE L__————————— —______ —__V- -_— EXISTING WINDOW PLUS NEW CANVAS AWNING W/ALUMINUM ARMATURE r-------------------, r---------, ----- r---- r---------, ---- t I o I I I 1 1 1 1 I 1 I I 1 1 1 1 1 ------------------- 6- PROPOSED ------------------6'PROPOSED NORTH ELEVATION- NEW CORP T SIGNAGE I I L_____________________________________ __ (V XISTING WINDOW # PLUS ❑ NEW CANVAS AWNING EXTERIOR COLORS W/ALUMINUM ARMATURE CMr---------------------------------------, r---------------------------------------, r---------------------------------------� HARDIE PLANK BRAND CLAPBOARD STYLE I I I I I I I I 1 I 0' - 4' "IRON GRAY" 625 PACIFIC 1 4' - ROOF "LIGHT MIST" 1 i i f I I 1 I \ I I I I CANVAS AWNING SUNBRELLA BRAND "GRAY" I I 5' PROPOSED FRONT ELEVATION � 171 MtM4+ e r pEC'UBMITTED: . REVISION 8 SCALE: Condon Engineering , P .C . 1 „ 1-_ ,_0„ MAR. 27, 2019 4 APR. 5 2019 _ 1755 Sigsbee Road DWG. No. POWER EQUIPMENT PLUS Mattituck, NY 11952 APR. 26, 2019 825 PACIFIC STREET MATTITUCK NY 11952 300.01 _________________________________________________________________________________________________J NEW HARDIE PLANK SIDING PAINTED CORPORATE COLORS NEW 4'-8"x 2'-4"AWNING WINDOW EW CANVAS AWNING PROPOSED SOUTH ELEVATION- NEW HARDIE PLANK SIDING PAINTED CORPORATE COLORS NEW 4'-8"x 2'-4"AWNING WINDOW 0 0 -NEW 8'OVERHEAD DOOR PROPOSED REAR ELEVATION :N -¢✓ 1 �« t �p DEC '4BMITTED: REVISIOSCALE: NS. Condon Engineering , P .C . 111 - 11-011 MAR.AR. 7, 2019 - - 1755 Sigsbee Road 4 APR. 5, 2019 POWER EQUIPMENT PLUS DWG. No. Mattituck, NY 11952 APR. 26, 2419 825 PACIFIC STREET MATTITUCK NY 11952 300.02 EXISTING ROOF EXISTING STEEL I-BEAM GIRDER----,,,, ---EXISTING 2"x 12"ROOF RAFTERS CV iv EXISTING EXTERIOR WALL 8"CONCRETE BLOCK TO BE SIDED W/ ERRING STRIPS(AS SPEC.IBY MFG.) HARDIE PLANK NEW CURTAIN WALL1 EXISTING INTERIOR WALL PAINTED IN CORPORATE COLORS "x 4"METAL STUD o 2NEW SUSPENDED CEILING 'PLASTER BOARD NEW DISPLAY SHELVING W/2'x 4'FIBER TILES STORAGE - EXIT —EXISTING 2"x 8"FLOOR JOISTS —ado ' NEW P.C.4"LEVELING SLAB COUNTER /!WITH W.W.M. ° ih COUNTER OU R STORAGE AREA d PROPOSED SECTION_ Vv, DATE SUBMITTED: DEC. 19, 2018 SCALE: REVISIONS: „ _ _Q„ Condon Engineering , P .C . -111 - 11-011 4 MAR. 27, 2019 1755 S i gs bee Road POWER EQUIPMENT PLUS DWG. No. APR. 5, 2019 APR. 26, 2019 825 PACIFIC STREET MATTITUCK, NY 11952 MattltUCk, NY 11952 300.03