Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
43277-Z
u� Town of Southold 11/1/2019 P.O.Box 1179 53095 Main Rd 1 # * t=^ Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 40827 Date: 11/1/2019 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 400 King St., Orient SCTM#: 473889 Sec/Block/Lot: 26.-2-14 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 12/5/2018 pursuant to which Building Permit No. 43277 dated 12/5/2018 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ADDITIONS AND ALTERATIONS INCLUDING COVERED PORCH TO AN EXISTING ONE FAMILY DWELLING,PER ZBA DECISION#6961, DATED 06-16-2016, AS APPLIED FOR The certificate is issued to Campbell,Peter&Heather of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 41 16 11-14-2018 PLUMBERS CERTIFICATION DATED 12-04-2018 Joe hit avage 17 UiK t rize i ature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY ,m BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit #: 43277 Date: 12/5/2018 Permission is hereby granted to: Campbell, Peter 179 Carroll St Brooklyn, NY 11231 To: Additions and alterations to an existing single family dwelling as applied for per ZBA & HPC approvals. Replaces BP# 41116 At premises located at: 400 King St., Orient SCTM # 473889 Sec/Block/Lot# 26.-2-14 Pursuant to application dated 12/5/2018 and approved by the Building Inspector. To expire on 6/5/2020. Fees: PERMIT RENEWAL $214.60 Total: $214.60 Bw ing I ector u TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 41116 Date: 10/26/2016 Permission is hereby granted to: Campbell, Peter & Heather 179 Carroll St Brooklyn, NY 11231 To: Additions and alterations to an existing single family dwelling as applied for per ZBA & HPC approvals. At premises located at: 400 King St, Orient SCTM # 473889 Sec/Block/Lot# 26.-2-14 Pursuant to application dated 10/18/2016 and approved by the Building Inspector. To expire on 4/27/2018. Fees: SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $429.20 -ALTERAT G $50.00 7' Total: $479.20 Building Inspector Form No 6 TOWN OF SOUTHOLD BUILDING DEPARTMENT T'o"rN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following. A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form) 3. Approval of electrical installation from Board of Fire Underwriters. 4 Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-425 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. _4_4�bsr_14 #1014710 New Construction: O'ld or Pre-existing Building: �( (check one) Location of Property: 40,0 jC w4 !:�'P 410.121 LT House No. Street Hamlet Owner or Owners of Property: for—pp Suffolk County Tax Map No 1000, Section IGber Block /lri Lot 2 • ��} Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted. $ pplicaf t Signature pF SOUjyol 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road CA- Southold, Fax(631)765-9502 P.O.Box 1179 G Q Southold,NY 11971 0959 �� • �o roger.riche rt(cDtown.Southold.n BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To. Campbell Address, 400 King St City Orient St: NewYork Zip 11957 Building Permit#- 41116 Section. 26 Block: 2 Lot: 14 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor DBA. Platinum East Electric License No 34091-ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor X Pool New Renovation X 2nd Floor X Hot Tub Addition Survey Attic X Garage INVENTORY Service 1 ph 300a Heat gas Duplec Recpt 79 Ceiling Fixtures 25 HID Fixtures Service 3 ph Hot Water gas GFCI Recpt 2 Wall Fixtures 16 Smoke Detectors Main Panel 2-15 A/C Condenser Single Recpt 1 Recessed Fixtures 65 CO Detectors Sub Panel A/C Blower Range Recpt 20a Fluorescent Fixture Pumps Transformer AppliancesE68 Dryer Recpt 20a Emergency Fixture Time Clocks Disconnect W Switches Twist Lock Exit Fixtures TVSS Other Equipment: 2-bath fans, range hood, well pump, 150A generator transfer switch, 8-ARC fault circuit breakers,7-GFCI circuit breakers Notes. Inspector Signature: c_ Date: November 14 2018 81-Cert Electrical Compliance Form.xls o y Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 Cou�m,�� ' BUILDING DEPARTMENT TOWN OF SOUTHOLD CER'T'IFICATION Date: .Z Building Permit No. Owner: A- 4et - 1 7 (Please print) Plumber:- 30e (Please print) I certify that the solder used in the water supply system contains less than 2/10 of I% lead. (Plumbers Signature) Sworn to before me this day of , 20/Y Notary Public, County CHRISTIE HAL60CK NNory�1950,Suffof ollk County k Commission Expires May 31,2 T 43fjf soo�o TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPEC ION [ ] FOUNDATION 1ST [ ROUGH PLEIG. [ ] FOUNDATION 2ND [ 4SULATION [ ] FRAMING / STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRIC L (FINAL) R MARKS: 90CJ4plV411m /,V/uvva�"oy%,�fj& ovv/ 04 el) r off,• � � v���'�r✓ rao DATE �'' INSPECTOR �oF soar COUNM TOWN OF SOUTNOLD BUILDING DEPT. 765.1802 INSPECTION [ ) FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION $4-' ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: d J� DATE Z �, INSPECTO `�3D T) oF So�,y°� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 NSPECTION [ UNDATION 1ST [ ] ROUGH PL13G. [ P6UNDATION 2ND [ ] INSULATION [ FRAMIN STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) R MARKS: 2ed4W r )LA � f w DATE I INSPECTOR �(�044 4111 ��pf SOUT,yO TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST ( ] ROUGH PLBG. [ ] OUNDATION 2ND [ ] INSULATION [ FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: L ✓ w lit DATE y INSPECTOR L4t (f t4 3aV OF SOUIyo� ia_o • o a TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] IRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRI AL (FINAL) REMARKS: r W LVWk�(044 6*iq 4��V+ 604 fwtz----� A✓� S S oK/ � iAelo" D-/ s/t.- 44- �d*vvtx-- A, ww o V, Ft A � DATE j I INSPECTOR oF souryO !o # * TOWN OF SOUTHOLD BUILDING DEPT. courm,v 765-1802 q 3t � INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE j INSPECTOR-421 �o��OF SOUIyo� # TOWN OF SOUTHOLD BUILDING DEPT. " �0 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] I SULATION [ ] FRAMING /STRAPPING FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: i 7 1 Lsk— DATE INSPECTOR o��OG SOl Telephone (631)765-1802 O Town Hall,53095 Route 25 Fax (631) 765-9502 l P.O.Box 1179 va y� Southold,New York 11971-0959 UNTY, SOUTHOLD TOWN LANDMARK PRESERVATION COMMISSION CERTIFICATE OF COMPLETION November 1, 2019 Heather&Peter Campbell 400 King Street Orient, NY 11957 (SCTM#1000-26.-2-14) This letter is to certify that you have completed your project to the satisfaction of the Southold Town Historic Preservation Commission in accordance with your Certificate of Appropriateness, issued on May 17, 2016. Should you have any questions, feel free to contact me at the number above. Sincerely, Tracey L. Dwyer Administrative Assistant Southold Town Historic Preservation Commission CC: file, applicant ROCKET INSULATION LLC 656 flIR PORI(DW POROROMfl,11T 11779 P- 6317509075 f 6317509076 OCT 2 9 2019 www.Rocket5prayFoam.com iNSU1,ATION 4 COATINGS rocketinsulation@gmail.com Insulation Certificate This Form must be filled out and posted to comply with building code requirements. The following products have been installed in accordance to manufacturer's guidelines by a qualified installer. Fiberglass Insulation manufactured by: Owens Corning /Certainteed Foam spray polyurethane manufactured by: Lapolla Industries Foam spray manufactured by: SWD Urethane Area Insulated Thickness/Aged R-Value** ROOF RAFTERS 7" NOMINAL CLOSED CELL FOAM R49 FLAT ROOF RAFTERS 7" NOMINAL CLOSED CELL FOAM R49 2X6 EXTERIOR WALLS 3" NOMINAL CLOSED CELL FOAM R21 FIRECAULK ALL PENETRATIONS AS PER CODE DOORS&WINDOWS LOW RISE FOAM ACCUVENT BAFFLES 1ST FLOOR CEILING R19X15 UNFACED FOR SOUND ALL INTERIOR WALLS R1 1X15 UNFACED FOR SOUND CRAWLSPACE CEILING 4.5" NOMINAL CLOSED CELL FOAM **Nominal thicknesses are representative of field,spray-applied foam material. R-Value is based on manufacturer's claims lobsite Address: 400 King St, Orient, NY 11957 Date of Installation:02/28/2018 Building Contractor: David Murray Design Installed By: Rocket Insulation LLC -Post Near Electric Panel- r. C ,. = 1 1 . V iJ I - ��krNWyf i S �, tF Lfa�� OCT 2 9 2019 s - i i A �I s (Strapping) Af (Strapping) r k i -- �1 � • \i r. �!1 (Demo) • a• t � �.4l p � �� � -•- A 4 '.x r (Footings) S�. aF�r * �ISit 4 �• v, Yo. (Footings) Llate . 1�r � , I ofAl (Foundation) (St • • ,fr (Foundation) (S . •• -.A (Strapping) • (Strapping) +' IM l , 77 r- •• • � . • yc�,yy .. E \ g� Y4 a1E, - A Vim, A x / ALAb� r. Milo TOW c Y ..I�.�\ l�. .. . . FIELD1NSPECTION REPORT , • 1 ���_ two FOUNDATION PLUMBING, M10119I M,-)m FOUNDATION (2ND) S 6A ROUGH FRAMING& _�wfic" :7 e► r -STATE ENERGY CODE . INSULATION PER N.Y- k, 1 I� i61i w4mWol .i7t�c ADDITIONAL JUN T r • TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT y Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 ;, , 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502u y South oldTown.NorthFork.net PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application ® ;Flood Permif Examined ,20 - iJ VVV � Single&Separate Storm-Water Assessment Form 1 ® MAR ;1' 9 Contact: Approved 1 ,20 �DEPT 1191 te" J Disapproved a/c / C7BJnTRJ:11'nngDI �'HO1� Phone: Expiration ,20 nspe. tor,,. ��- • °; • o d°`�-.PLICATION FOR BUILDING PERMIT D 'D Date , 20 INSTRUCTIONS , a. Ph�is�applo a RNMUST be completely filled in by typewriter or in ink and submitted.to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. lSb7MW3W1DZk location of lot and of buildings,on premises, relationship to adjoining premises or public streets or areas,TtW8'.eLrgDLD c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so,e"ver until the Building Inspector issues a Certificate of Occupancy-, ,• _ ' f. Every building permit shall expire if the work,authorized has not,comrgencbd4ithin 12 months after the date of i"ssuanpe or has not been completed within l8 months from-such date. If no zoning amendments-or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Therea'fte'r,'a ne"W permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordin. nce of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable`laws, ordinances,building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name, if a corporation) (MailRig address of app 'cant) I l8 State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder Name of owner of premises Imo, (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 1~is. House Number Sihet „ Hamlet County Tax Map No. 1000 Section l®4® Block Lot • /� Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy 1094 � b. Intended use and occupancy W* j,Art-- 3. Nature of work(check which applicable): New Building Addition Alteration A Repair Removal Demolition Other Work (Description) 4. Estimated Cost Q�q � B �'� � � ,�� �"44a�,�'1 paid on filing this application) 5. If dwelling, number of dwelling unitsy Number of dwelling, nits on each floor If garage, number of cars �1 ` 6. If business, commercial or mixed occupancy, specp, aa U's of each type of use. yy ;: `xG f 4~h•j;{e y!� 1 7. Dimensions of existing structures, if any: Front ('� Reo .01 Depth 151. Height (0)'• (� Number of Stories 11k2 Dimensions of same structure with alterations or additions: Front "°12 R 9114 Depth tHeight Number of Stories ` P< � ', 8. Dimensions of entire new construction: Front Rear ;A, Depth oil ,� .s.., Height Number of Stories , a' tz %<:; 9. Size of lot: Front 1 171 .1 Rear Depth , I G►2 • 10. Date of Purchase 2®I r7' Name of Former Owner 11. Zone or use district in which premises are situated +49 � •�`�",r� � tar;h,;�t 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES_)(_NO ftoaaVA 14. Names of Owner of premises Address dkyjg& Phon o. Name of Architect Address Ift I I'tA -* . Phone No ���• /L7•��� Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NOX * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with'respect to this property? * YES NO_� *'IF-YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF being duly"swor'ri, depose'§ and says'that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the a (Contract r,Agent, orporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworno before me this `,� - day of 0LIrCY 1 2016 r " ' ` ' °TRACEY L. DMER NOTARY PUBLIC,STATE OF NEW YORK Notary P b is No.01DW63069 QUALIFIED IN SUFFOLK COUNTY ignature of pplicant COMMISSION EXPIRES JUNE 30,22a•- James Garretson,Chairperson Town Hall Annex Anne Surchin,Vice ChairC4Gy 54375 Route 25 Donald Feiler PO Box 1179 James Grathwohl y Southold,NY 11971 Robert Harper' Fax(631)765-9502 Gary Parker Telephone: (631)765-1802 Edward Webb- Ol �a www.southoldtownny.gov Damon Rallis,Administrative Assistant Town of Southold Historic Preservation Commission RESOLUTION #5.17.16.2 May 17,2016 Certificate of Appropriateness RE: 400 King Street, Orient, SCTM# 1000-26.-2-14 Owner: Heather&Peter Campbell RESOLUTION: WHEREAS, 400 King Street, Orient,NY is on the Town of Southold,New York State and National Registers of Historic Places, and WHEREAS, as set forth in Section 56-7 (b)of the Town Law(Landmarks Preservation Code) of the Town of Southold, all proposals for material change/alteration must be reviewed and granted a Certificate of Appropriateness by the Southold Town Landmarks Preservation Commission prior to the issuance of a Building Permit, and WHEREAS, an application was submitted to construct substantial additions and alterations to the existing single family dwelling, and WHEREAS, the applicant's representatives presented this proposal to the commissioners at a pre-submission conference on April 19, 2016 and, and WHEREAS, a public hearing for the purpose of considering approval of the proposal was held on May 17,2016 NOW THEREFORE BE IT RESOLVED,that the Southold Town Historic Preservation Commission determines that the proposal as outlined in plans submitted by Kevin Perry, architect, subject to the conditions above, meet the criteria for approval under Section 170-8 (A)of the Southold Town Code and, BE IT FURTHER RESOLVED,that the Commission approves the request for a Certificate of Appropriateness. MOVER: Vice Chair Anne Surchin SECONDER:Commissioner James Grathwohl AYES:Unanimous RESULT:Passed Please note that any deviation from the approved plans referenced above may require further review from the comp Signed: Damon er Rallis,Ad ative Assistant to the Southold Town Historic Preservation Commission Date: BOARD MEMBERS v S® Southold Town Hall Leslie Kaenes Weisman,Chairperson ��o Ujy® 53095 Main Road•P.O.Box 1179 �® �® Southold,NY 11971-0959 Eric Dantes Office Location: Gerard P.Goehringer Town Annex/First Floor,Capital One Bank George Horning 0 ® �� 54375 Main Road(at Youngs Avenue) Kenneth Schneider CouVSouthold,NY 11971 D http://southoldtown.northfork.net D ZONING BOARD OF APPEALS JUN 2 0 201 TOWN OF SOUTHOLD Tel.(631)765-1809•Fax (631)765-9064 BUILDING DEPT. TOWN OF SOl{JTHOLD FINDINGS,DELIBERATIONS AND DETERMINATION MEETING OF JUNE 16,2016 ZBA FILE: 6961 NAME OF APPLICANT: Heather and Peter Campbell PROPERTY LOCATION: 400 King St., Orient,NY SCTM#1000-26-02-14 SEORA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under the Suffolk County Administrative Code Sections A 14-14 to 23, and the Suffolk County Department of Planning issued its reply dated May 2, 2016 stating that this application is considered a matter for local determination as there appears to be no significant county-wide or inter-community impact. LWRP DETERMINATION: The relief, permit, or interpretation requested in this application is listed under the Minor Actions exempt list and is not subject to review under Chapter 268. TOWN OF SOUTHOLD HISTORIC PRESERVATION COMMISSION: The application was referred to the Commission for its review pursuant to Section 170-8 (A) of the Southold Town Code. A decision to approve the request for a Certificate of Appropriateness dated May 17, 2016 was received by the ZBA on June 7, 2016. PROPERTY FACTS/DESCRIPTION: The subject parcel is a 20,414 square feet non-conforming lot in an R-40 Zoning District. It fronts King Street for 117.78 feet; the western property line is 178.24 feet, the eastern property line measures 167.44 feet and the rear property line measures 118.82 feet. The parcel is improved with a pre- existing one and one half story frame dwelling, a pre-existing two car garage with attached frame shed and a one story frame cottage, all as shown on the survey/site plan, sheet SD.01, dated April 1, 2016, prepared by Kevin Perry,R.A. with survey data taken from a survey, prepared by Kenneth Woychuck, L.S. dated September 28,2015. Existing lot coverage is 14.47% as calculated by Kevin Perry, R.A. in his correspondence dated June 6, 2016. This parcel is within the Historic Landmark District and subject to the Historic Preservation Commission. BASIS OF APPLICATION: Request for Variances from Article XXIII Section 280-124 and Article III Section 280-15 and the Building Inspector's March 15,2016 Notice of Disapproval based on an application for building permit to additions and alterations to existing single family dwelling and construct in-ground swimming pool, at; 1) less than the code required front yard setback of 40 feet, 2)lot coverage at more than the code permitted maximum of 20%, 3)following proposed construction existing accessory garage/shed will be located in other than the code required rear yard, located at: 400 King Street Orient,NY. SCTM#1000-26-2-14 R Page 2,June 16,2016 #6961, Campbell SCTM No. 1000-26-2-14 RELIEF REQUESTED: The applicant requests variances to: 1) construct additions and alterations to the existing dwelling having an 8+/- foot front yard setback where the code requires a 40 foot minimum front yard setback, 2) construct additions, alterations and accessory structure (in-ground swimming pool) having a total lot coverage of 26.4% where the code permits a maximum of 20%, and 3) due to proposed construction, place pre-existing accessory structure(garage with attached shed) in a side yard location where the code requires a rear yard location, all as shown on the Site Plan/Survey, sheet SD.01 and architectural drawings sheets SD.02, SD.03, SD.04, SD.05 and SD.06 all dated April 1, 2016 and prepared by Kevin Perry,R.A. AMENDED APPLICATION: During the hearing, the applicant was asked to bring the plan into more conformity with the Town Code. The applicant, on June 6, 2016, submitted a plan decreasing the lot coverage to 23.87%, and bringing the plan into more conformity with the codes with respect to the original request for 26.37% total lot coverage. ADDITIONAL INFORMATION: The applicant submitted a list of variances granted, in the area, for lot coverage greater than 20% as evidence that may mitigate the substantiality of the requested proposed and amended lot coverage.Below is an analysis by the Board. Appeal 44881 for 170 Orchard St. in 2000 was granted a lot coverage variance of 34.4%. This lot is 8460 square feet. The existing lot coverage was 32.15%. This is a small lot, approximately 2/5 the size of the applicant's lot which has an institutional building(former Orient firehouse)that has been converted to a dwelling use and to use it as a comparison for lot coverage is not justified because of the lot size differential between them and the previous use of the existing structure. Appeal 44890 for 2495 King St. in 2000 requested a lot coverage variance of 22.3% and was granted a lot coverage variance of 21%. This lot is 11,812 square feet and its existing lot coverage was 7.6%. This is a small lot, less than 3/5 the size of the applicant's lot and was granted alternative relief for maximum lot coverage of 21%. This Appeal, compared to the others in this analysis, is the closest resemblance to what the applicant proposes. Appeal #5436 for 2360 Village Lane in 2004 was granted a lot coverage variance of 23.2%. This lot is only 4500 square feet and its existing lot coverage was 21.25%. It is not uncommon for lots of this small size to require a lot coverage variance. This is a small lot, less than 1/4 the size of the applicant's lot and to use it as a comparison for lot coverage is not justified because of the lot size differential between them. Appeal #5847 for 230 Vincent St. in 2005 was granted a 21.7% lot coverage variance. This lot is 10,044 square feet. This is a small lot, less than 1/2 the size of the applicant's lot and to use it as a comparison for lot coverage is not justified because of the lot size differential between them. Appeal #6130 for 145 King St. in 2008 was granted a lot coverage variance of 28.25%. This lot is 6732 square feet and its existing lot coverage was 27.4%. It is not uncommon for lots of this small size to require a lot coverage variance. This is a small lot, less than 1/3 the size of the applicant's lot and to use it as a comparison for lot coverage is not justified because of the lot size differential between them. Appeal #6720 for 560 Village Lane in 2014 was granted a lot coverage variance of 23.4%. This lot is 12,569 square feet and its pre-existing lot coverage was 23.5%. This is a small lot, approximately 3/5 the size of the applicant's lot, with pre-existing non-conforming lot coverage of 23.5% and the lot coverage variance granted was a reduction in lot coverage, all of which does not justify this Appeal to be used as a comparison for excessive lot coverage. Page 3,June 16,2016 #6961, Campbell SCTM No. 1000-26-2-14 There exists a section of the applicant's rear yard fencing in the southwest corner of this parcel that protrudes onto the adjoining property. The applicant proposes to relocate this fencing onto this property. The adjoining property to the west is in opposition to the requested variance. FINDINGS OF FACT/REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on June 2,2016, at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property and surrounding neighborhood, and other evidence,the Zoning Board finds the following facts to be true and relevant and makes the following findings: 1. Town Law &267-b(3)(b)(1). Grant of the variance for a front yard setback of 8+/- feet will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The pre-existing dwelling has a 2.3 foot front yard setback and the proposed additions and alterations in the front yard will be setback further from the front property line and will be similar in style as to what exists today. Grant of a variance for a side yard location of the pre-existing two car garage with attached shed, due to the proposed construction, will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The two car garage with attached shed is pre-existing and is historically characteristic of the neighborhood. Grant of a variance for 23.87% lot coverage as noted in the Amended Application will produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. Excessive lot coverage on locally medium sized parcels, such as the applicant's, will change the historical character of this neighborhood and set an undesirable change with excessive lot coverage. 2. Town Law X267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance for a front yard setback. The majority of the dwelling exists in its pre-existing non-conforming front yard location and any proposed additions and alterations will require a front yard setback variance. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance for a side yard location of the pre-existing two-car garage with attached shed. The two-car garage with attached shed, with respect to the pre-existing dwelling, pre-exists narrowly in a conforming rear yard location. Any additions or alterations to the pre-existing dwelling in the rear yard will place the two-car garage with attached in a non-conforming side yard location. To relocate these long standing historical structures would not be feasible. The benefit sought by the applicant can be achieved by some method, feasible for the applicant to pursue, other than an area variance for lot coverage greater than 20%. The existing total lot coverage is 14.47% and a plan to increase the existing lot coverage to conform to the code is feasible. 3. Town Law §267-b(3)(b)(3). The variance granted herein for a front yard setback is mathematically substantial, representing 80% relief from the code. However, the pre-existing front yard setback is 2.3 feet and the proposed front yard setback is 8+/-feet, bringing the parcel into more conformity with the code. The variance granted herein for a side yard location of the pre-existing two car garage with attached shed is mathematically substantial, representing 100% relief from the code. However, this structure is pre-existing, narrowly in a rear yard location with respect to the pre-existing dwelling, and any additions and alterations such that are proposed will unavoidably place this accessory structure in a side yard location. IL Page 4,June 16,2016 #6961,Campbell SCT'M No. 1000-26-2-14 The variance requested herein the amended application for 23.87% lot coverage is mathematically substantial, representing 19%relief from the code. The variance granted herein for alternative relief of 22% maximum lot coverage is not substantial, representing 10%relief from the code. 4. Town Law §267-b(3)(b)(4) No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. The applicant must comply with Chapter 236 of the Town's Storm Water Management Code. S. Town Law $267-b(3)(b)(5). The difficulty has been self-created. The applicant purchased the parcel after the Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of purchase. 6. Town Law §267-b. Grant of the requested relief for a front yard setback of 8+/-feet and the location of the pre- existing two car garage with attached shed in a side yard location is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of additions and alterations to the pre-existing dwelling, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. Grant of alternative relief for maximum lot coverage of 22% is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of improvements to this parcel while preserving and protecting the character of the neighborhood and the health,safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Schneider, seconded by Member Weisman (Chairperson), and duly carried,to GRANT the variance for an 8+/-foot front yard setback and a side yard location of the pre-existing two car garage with attached shed as applied for, and shown on the survey/site plan, sheet SD.01, dated April 1, 2016, prepared by Kevin Perry,R.A. DENY the variance as applied for of lot coverage of 26.37% in the original application and DENY the variance as applied for of lot coverage of 23.87% in the Amended application, and GRANT ALTERNATIVE RELIEF for 22% maximum lot coverage. SUBJECT TO THE FOLLOWING CONDITIONS: - 1. Installation of a de watering dry well large enough to accommodate the discharge of pool water. 2. All pool equipment must be placed in a sound proof structure. 3. Any and all fencing that encroaches upon adjoining properties shall be removed and/or relocated to the applicant's property before a building permit is issued. That the above conditions be written into the Building Inspector's Certificate of Occupancy, when issued. Page 5,June 16,2016 #6961, Campbell SCTM No. 1000-26-2-14 Any deviation from the survey, site plan and/or architectural drawings cited in this decision will result in delays and/or a possible denial by the Building Department of a building permit, and may require a new application and public hearing before the Zoning Board of Appeals. Any deviation from the variances)granted herein as shown on the architectural drawings, site plan and/or survey cited above, such as alterations, extensions, or demolitions, are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity. Before applying for a building permit, the applicant or agent must submit to the Board of Appeals for approval and filing, two sets of the final:site plan, including recalculation of lot coverage conforming to the alternative relief granted herein. The ZBA will forward one set of approved, stamped drawings to the Building Department. Failure to follow this procedure may result in the delay or denial of a building permit, and may require a new application and public hearing before the Zoning Board of Appeals. Pursuant to Chapter 280-146(B) of the Code of the Town of Southold any variance granted by the Board of Appeals shall become null and void where a Certificate of Occupancy has not been procured, and/or a subdivision map has not been filed with the Suffolk County Clerk,within three (3)years from the date such variance was granted. The Board of Appeals may, upon written request prior to the date of expiration, grant an extension not to exceed three (3) consecutive one (1)year terms. Vote of the Board: Ayes: Members Weisman (Chairperson), Schneider, Dantes, Horning, Goehringer. This Resolution was duly adopted (5-0). OL- � Llvu= Leslie Kanes Weisman, Chairperson Approved for filing �p //� /2016 Scott A. Russell ��-°SUS` ��� STO][ IM[WAT)ER, SUPERVISOR ' AWANA(G IENHENT SOUTHOLD TOWN HALL-P.O.Box 1179 O 53095 Main Road-SOUTHOLD,NEW YORK 11971 Town9'ffq'�[R�~ n V CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET 2016 ( TO BE COMPLETED BY THE APPLICANT ) BUILDING DEPT. TOWN OF SOUTHOLD ®IES--PHIS-ll'l OJEI C;7t-INVO L-V]E ANS'-OF-T H[]E-IFOLLOWINti: ------ - Yes No (CHECK ALL THAT APPLY) ❑�, A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑fZC. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑RL D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ® E. Site preparation within the one-hundred-year floodplain as depicted on FIRM Map of any watercourse. ❑ F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT. (Property Owner,Design Pro essional,Agent Contractor,Other) S.C.T.M. 1000 Date: Dutnct I /n�,^ NAME w�o Section Block Lot <`FOR BUILDING DEPAf?'rNI NT L-SI: 0NL�' "k Contact information 7, 7C I e, r..1 ft, : d 0 y1^--C Reviewed By e- — — — — — — — — — — — — — — — — — — Date Property Address / Location of Construction Work: — — — — — — — — — — — — — — — — — +00 '��-� -71 Approved for processing Building Permit. Stormwater Management Control Plan Not Required ��- 7 - ❑ Stormwater Manage;rient Control Plan to Required. (Forward to Engineering Department for Review.) FORM 4 SMCP-TOS MAY 2014 o�a����otK�o Town Hall Annex j� GTelephone(631-1802 54375 Main Road Fax(631)734-9502 P. O. Box 1179 Co ZM Southold, NY 11971-0959 BUILDING DEPARTMENT NOTICE OF UTILIZATION OF TRUSS TYPE CONSTRUCTION PRE-ENGINEERED WOOD CONSTRUCTION AND/OR TIMBER CONSTRUCTION Date: __ I• A —"'�i Owner: Location of Property: le-we" e-bye Please take notice that the (check applicable line): New residential structure Addition to existing residential structure Rehabilitation to an existing residential structure ' to be constructed or performed at the subject propertyreferegce above will utilize (check applicable-line): Truss type construction (TT) Pre-engineered wood construction-(PW) Timber construction (TC) in the following location(s) (check applicable line): Floor framing, including girders and beams-(F) Roof framing (R) Floor and/roof framing (FR) Signature: Z 4e-zo—ri Name.(person submitti -g this for ): Capacity(check applicable line): Owner Owner representative _ TrussResReg15.docx Effective 1/1/2015 6" DIAMETER : REFLECTIVE RED ROMAN ALPHANUMERIC - --PANTONc- - - -"- -- -- -" --- ----uESIGNATION-OF-CONSTRUCt-ION - - (PMS) #987 TYPE BASED ON SECTION 602 OF THE BUILDING CODE_OF NEW -YORK STATE ' 2" MIN. REFLECTIVE WHITE 112" STROKE _........_-- --- --------- DESIGN-ATtON'FORSTRUCTIfRAL ---- COMPONENTS THAT-ARE'OF- TRUSS CONSTRUCTION "F" FLOOR FRAMING, INCLUDING GIRDERS AND BEAMS "R" ROOF FRAMING '"FR" FLOOR AND ROOF FRAMING TRUSS IDEMBFICA11ON SIGN COI1 DUANCE WITH 19[ IYCRR PART 12654;-.q U7TOSCvE EF-ff-l.A'pZTMC'N DIVISION EYA RLE TRUSS IDENTIFICATION SIGN`-- DATE:UO&2005 NES PORI 'STAT�E-'D'EPARTMENT OF STATE DIVISION OF CODE ENFORCEMENT AND ADMINISTRATIONT•.1]F 5 1`6c .rzZ4 ��SUFFOCK�O Town Hall Annex Telephone(631-1802 54375 Main Road P. O. Box 1179 Fax(631)734,<9502,,. - 4 �' co z Southold, NY 11971-0959 �y BUILDING DEPARTMENT NOTICE OF UTILIZATION OF TRUSS TYPE-CON,STRUCTIONPRE-ENGINEERED WOOD CONSTRUCTION AND/OR TIMBER CONSTRUCTION Date: Owner: Location of Property: 14 Please take notice that the (check applicable line): New residential structure Addition to existing,residential structure Rehabilitation to an existing residential structure to be constructed or performed at the:subject,pr©perty..reference.above will utilize (check applicable line): Truss type construction (TT) �C Pre-engineered wood-construction (,PW) , Timber construction (TC) ' in the following location(s) (check applicable line): Floor framing, including girders and beams (F) Roof framing (R) Floor and roo framing (FR) Signature: Name (person submitti g this for ); Capacity(check applicable line): - Owner Owner representative - - TrussResRegl5.docx Effective 1/1/2015 h ant � o Town Hall Annex t Telephone(631)765-1802 54375 Main Road ax(631)76�-,95t�2�. P.O.Box 1176 ® a0 r0 er.richert Own.sOu 0 a n .us Southold,NY 11971-0959 Cow,1� BUILDING DEPAMffNT T(D ®1F S(IDUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: Company Name: UA-L lilarne:_ -- License No.: 3 07 , el �V- Address: �` �-�S /�� SU✓`ffv /l% l� '7 Phone No.: JOBSITE INFORMATION: (*Indicates required information) Name: ( AM CILL 2C--S c 0&-c-cc Address: yo® k&y� S t Q P tLiS L *Cross Street: *Phone No.: Permit No.: Tax Map District: 1000 Section: Block: �, Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) ,223 6o SQ �F+ (qouScf ?00 /SMP Sexv Ccs oo - ---- ---- -- - ;��.2�- - - - -f- --- - (Orgy - �-------- --- -.--- ---___ (FIsease Circle.all That Apply) *Is job ready for inspection: YES/C'vy� Rough In Final *Do you need a Temp Certificate: YES NO Temp 8nfornvation (if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect ndergroun Number of Meters Change of Servic Overhead Additional lnfc tilgcln PAYMENT DUE WITH APPLICATION _ .Yo' .1 %.J - I �c d pec W5& APR 18 2017 a 82-Re u or G DEPT. OWN OF SOUTHOLD BUILDING ;DEPARTMENT'` TOW;IV 'OF SO"UTHOtD • y�," Town HallAnOOe 54875:Main;Road P4.6ox7179`•.8outhoid,NY`1197.1=0959 i` ! ���'4UNt't,"� - "'Telephone{831}'765='1802•"Fak"{681}765.9502` = ,w ;,: . • , NuMbdr of Meters_ Temporary Cerfif'icate ' i IZL Overhead"G.,t7ndergrouricf r New,Serv�t a _0. .Change.of ervtce ReconnecfiExist_ing Seivice" 'p. .. IGCI� installed by :/!" �7''�1 . �C.t✓ . Cic.# ���`t;t� �''{'~` Reference T Application:for'eiectri al:service equipmep#:is ort file with the.Town of:Southend:Cin-applicant's.no#i#kation- ? F that this"installatiori is complete,:.the;#own wrilt.conduct.a premises inspectic►ii of.the."service equipmeTit i a' This-vgr!,j valid,fo �t'Yay cIffe ab6we:06te. Authorized"bjr �4 i 4 � . Southold Town Building Department P.O.Box 1179 Permit#: 41116 53095 Main Rd Southold,New York 11971 Permit Date: 10/26/2016 (631) 765-1802 Expiration Date: 4/27/2018 Parcel ID: 26.-2-14 BUILDING PERMIT RENEWAL LETTER Dated: 11/20/2018 Applicant: Campbell, Peter Location: 400 King St, Orient Work Description: ADDITION/ALTERATION Additions and alterations to an existing single family dwelling as applied for per ZBA&HPC approvals. A FEE OF $214.60 IS REQUIRED TO RENEW THIS BUILDING PERMIT. Owner: Campbell, Peter&Heather Address: 179 Carroll St Brooklyn,NY 11231 The permit listed above has expired. No work is permitted or authorized beyond the expiration date. Please submit the above fee made payable to the Town of Southold. Mail to the Town of Southold Building Department, P.O. Box 1179, Southold,New York 11971 THANK YOU, SOUTHOLD TOWN BUILDING DEPT. iZ .-, 1_4 Existing Loam Soil 1-011 ---" e Inlet maintain 1/4" per foot pitch t , - YYllri � from leader t ct ❑ Existing 1 story s , O Clean out hatch \ \ O � rn cottage , it t til : i' i New Drywell J f \ o ,- F'F i' \` .F i /, s Jr J/ f' ,. ,F , \ i .... ,.. .....� :.:Y". '.i:iwr��ta,: .�,.;,., '•__, _,_ ___ _ '..r.t ' f f r r New clean sand f,_. Existing permeable soil p New drywell for pool overflow - �'�' P + o t , Water level New Pool 18' x 36 . .... . . . . .. .. . . Existing Typical drywell I septic system I Side yard i to remain \`,Minimum t ` F, i Notes E�i8ting-=� ------- ---------- ---------- - 'shed F f 1 . All drainage structures are to be a minimum of 20 feet from the leeching its of the septic system. ❑ 2. Drainage calculations: Roof area 2,663 SF with 2" holding capacity--443 CF capacity required / �' ,F�°`` Each 8' x 10' ring provides 250 CF x 2=500 CF provided. J �1S g p �agel"''' .� it 3. Maintain existing gravel drive way for silt and mud control. p Addition 4. Provide filter fabric at base of fences in areas of excavation to control silt run t off. New 8' dia x 5' high drywell , , t , , , , , t � t , Q 7:; 7:� o t+ w Existing House tk Remain l \ J Picket Fence New 8' dia x 5' high drywell ------------ K I N STREET o � D Proposed Site Plan a N;6 liU�LDIN�D��• To`vVN OF SOUDOLD Devin Perry Architect kevinperry@att.net Alterations to 400 I<ing Street, Orient NY 212.727.9907 Site Water Managment October 11 , 2016 ON081SPN8V ssviono(j 30 New fence inside Zoning J0 J/N 0 NV9 3,s• property line S 9*,7 J/N CINV� A61 MOONS 3aVAOO'S 99 Ditrict: R-40 S9-o 30N3J Lot # 1000 26.2.14 8.8I I 0 130 13 Lot is a nonconforming lot, bulk regulations k M"R*O, 0- ------- 0 COTTAGE \------------ COTTAGF 280-124 apply. The proposed Lot coverage U1 X exceeds the 20% allowed. X, ------ XX• ubx✓ll C) [313 13 ----------------------- 'do OIS" C-0 d-n ------------ 0) Lot Coverage exsiting proposed d'9 C4 - ------------ Cr) o ' n Grade Patio °� n '' o t i y accesory cottage 418 SF 418 SF New�ool 0 0 M ........ 18'x)6' -------- ----------- -9 --------------- garage and shed 695 SF 695 SF C M z M C) house • r 1841 SF 2 414 SF orch Side yard SF 249 SF p Side yard U m 35'max combined deck SF SF 0 rri �D Existing z septic system pool sf 648 SF U) ZD to remain z - \,\\\ ' total 2,954 SF 4,424 SF t 1 rr] ff,7 QD 1 ❑0 19, f I/le 201 8fX ----------------------- lot area 20 414 SF 20 414 SF 13 X/, " Extsitinremoved /" , g V proposed lot coverage 14.47% 21.67% Patio n grade New Fence/ Gate Addition 83MOHS N08dV Pool notes �800cuno V) Cf) N� * AIM >10188 IN3 V9*t 70083d 1. Install dewatering dry well large enoug X h to M: W 30 accommodate discharge of pool water. 0 .30N3J 381M � " , \!`:./`�/` 2. Pool equipment to be placed in a sound proof doo.LS M 6 Fence/Gate 0 structure. < C) 7� C3 \J VNI P 1 A�JAA ;--4 > I / I >1 M tQ CC) ZZ, 0 -r-Exisungl ouse W Remain U /Cy p Exisiting emoved 99-Z69 CPicket Fence L——————— —— VIVAA �4,')JMq Nid N081 ci-n a 0-PC 9-PO 9 9N N08dV c 9/, T T act-d-n -nVM 838MI KING STREET KING STREET IN3n3AVd JO 3003 Existing Site Plan Lm-.P---r Proposed Site Plan Survey data taken from survey prepared by Ken 20,414.25 SQ.FT. or 0.47 ACRES Woychuck dated 09/28/2015. Trees and bed CORRECTED LOT AREA 09-28- 15 locations added and are approximate. L-1 One Story Addition Two story rear addition Two Story Extension Extend Porch Gable roof One Story Addition %/ \/, \ Remove two story rear addition X X X XX X -T— --Two Story living space \ / / � Two Story Addition Low flat roof One Story w/ attic Original Salt Box contemporary addition One Story ——— \ \\\\\\ Enclosed and SEIMEd porch Reconstruct as Open Porch \Approximate Enc of 1920's porch Remove porch extension Existing Removals Proposed Kevin Perry Architect Alterations to 400 Kin Street, Orient QTY ke-vinperiT@att.net 212.727.9907 Site Plan -T \\7 Revised October 5, 2016 to comply with ZBA resolution #6961 ON081SPN8V ssvionoc J0 New fence inside Zoning 30 JAN ONVI 3,8• property line J/N CINV-1 AC400600019ST T 99 S#97 Ditrict: R-40 3aV>'00':Sf S9-o 30N3J Lot # 1000 26.2.14 ....... -0 . ..... '0 13 Lot is a nonconforming lot, bulk regulations I z M 2'0%--- 'A 0 1 STORY --------------" COTTAGE 280-124 apply. The proposed Lot coverage z exceeds the 20% allowed. .......... C) 13 0 \IN P -------- ------------ 0) 11 1 Lot Coverage ex icing proposed -d'n Cz U) -------------- U) n Grade Patio accesory cottage 418 SF 418 SF rri New 0 �001 ❑ M Cz 18 x 36' ---------------------- --------- ❑ garage and shed 695 SF 695 SF 0 z house 1841 SF 2 414 SF 15' of-oft porch SF 249 SF C) 2 Side yard ni Side yard \Mimum U) deck SF SF E3 35'max combined 13 FL; Existing z septic system X/ pool sf 648 SF T. U) C) ZD to remain -T1 " total 2 954 SF 4,424 SF M -T1 191-111, C3 20'-5%' X 1-1 � L r. --------------------- area 20,414 SF 414 SF 20 M,9*0 ........... 13 X j ar ///'Ex�§ ng11 Exisiting removed proposed lot coverage 14.47% 21.67% ge� " i New Fence/ Patio on gra e Gate Addition z - I I i 83MOHS N08dV 'JN00 011Vd 0 Pool notes E" 0 800(iino >10188 cq Cn 'Ai> J! W (Y >X XlVM >1018e Install dewatering dry well large enough to cn 91 X V10083d accommodate discharge of pool water. —1 13JN3J 381M ;t dools I'll, 2. Pool equipment to be placed in a sound proof W M > *JN03 C) Fence Gate structure. tructure. TQ Z 12'-71/111, C) <M ii -� rCp-`; 'rf/"•,!`':/J./r`>,: '\_'Jf/`.^.`.,/f/\J.'r J'/ :.t`Or,'/N•1l.`�:/f'rJH'f�'.fr`�,..,r>'?�;'F /rr\/'/r°r/r'J"/f`/`�,`/ � C3 � 4-4 0' L:�4 , " co I , 00 X rr FP 0 zz / o Existing I louse t:)Remain X U oil /Exisiting mov d /Exisi /Exisiting /Exisi e 99*Z 6 A Picket Fence L———————---— \>44-1 VAMA N/d M11 0-PC 0-V0 9 gi\T '��'07 N -d-n 3AIds *4 T T -d-n 41 N08dV 'Nl8 '0138 -11VM 838MI KING STREET KING STREET 1N3kV3AVd J0 3003 Exisfing Site Plan Proposed Site Plan Survey data taken from survey prepared by Ken 20,414.25 SQ.FT. or 0.47 ACRES Woychuck.dated 09/28/2015. Trees and bed CORRECTED LOT AREA 09-28- 15 locations added and are approximate. One Story Addition Two story rear addition Two Story Extension Extend Porch Gable roof Remove two story rear addition One Story Addition L /X Two Story living space —J] Two Story Addition Original Salt Box Low flat roof One Story w/ attic contemporary addition One Story ——— jEnclosed and enlarged porch L\ Reconstruct as Open Porch \Approximate line of 1920's porch Remove porch extension Existing Removals Proposed Kevin Perry Architect Alterations to 400 Iaing Street, Orient NY kevinperry@att.net 212.727.9907 Site Plan Revised October 5, 2016 to comply with ZBA resolution #6961 ON08iSW8d J0 Zoning $Sb'l0(lOa New fence inside g 30 3/N ONVI 3,9'C property line _ 3/N ONHI Mccg'Qc°o�w, gS �� lS ,9 S`97 e Ditrict: R-40 S9'0 ��N3J3dLot # 1000 2 6.2.14 Z9.9TT Fnce — Ir- 1 The proposed Lot coverage complies with c `i N ° 1 STORY i a v>__----I-----" ' ° ` -----'----- \ the ZBA resolution for this project. 8'Z ; ` 'f �, COTTAGE �\ p 1 ' o - ------------------------ --------- 13 0 �. !I; ----- --- lools ------------ 'ON00 rn dn I --- ' Lot Coverage exsi"' proposed osed d' CD New ool ------- ----- 16 x 2' I —i ' V) , , o of O n accesory cottage 418 SF 418 SF t, ° ! ' ----------- - - garage and shed 695 SF 695 SF M ` ' I house 1 841 SF 2 414 SF n ------ V m ence f/ \� :; , c� .V porch S 249 SF C7 % 201-011 � ` Side yard Side yard ! 1 `\Minimum deck - SF - SF = M,.V ---- �f I ) , ` ❑ 35'max combine t ;- ( �' \ ❑ I z l �I ( sceptiFExisc system I ; �`�� pool - sf 648 SF - �� D to remain o I z� Z total 12954 SF 4,424 SF o ; ❑o ,/ ;10 ❑o a - L _ - -J m D ---- t lot area 20,414 "SF 20,414 SF '9'0 \ ❑ m ❑ Fend proposed lot coverage 14.47% 21.67% New Fence/ Q Gate Addition _ 213MOHS I Pool notesq3 �'� owed I ZD NO2�dt/ 'ON00 X101218 2f0001n©- Ln I j "n W '1N3 1. Install dewateringd well large enou li to 3 m �1dM �o�ae tno�a3d W1130 `9 -- — — accommodate discharge of pool waterg. tkI g i X g p 0 30N33 381M Z doors 2. Pool equipment to be placed inn' a sound proof O > m 'ON00 N Fence Gate W o I �, structure. r^ O m m I ❑ Oco 31. b '� v 1r ItQ p CC) u (Y ►{� 0 �0 a) 1:1Existing Hous Rem 'n 0 T I O coco c S,9'z C 3,8'0 _ Picket Fence Nid Nodi •d•n •d J P -Po9RN 'C'z 3)11dS N08dd 'H18 '0138 Ilb'M 838W11 KING STREET KING STREET 1N3W3AVd d0 3003 Existing Site Plan Proposed Site Plan Survey data taken from survey prepared by Ken 20,414.25 S Q.FT. or 0.47 ACRES Woychuck dated 09/28/2015. Trees and bed CORRECTED LOT AREA 09-28- 15 locations added and are approximate. i i Q'f1. 16 L'.• 'Til_ n�4; x Alterations to 4001,*, S treet Orient NY! gSite Plan December, 8 2016 I � I Woo Burning hove offset in enclosure above 8 2'-10" _ S hearth 7/7 / T__q � Clear o fr `\ O i / \ \N G„ ,_3 G„ 3'-8$„ / - -N— — N _ O ALine of girder above RB,r Kitc Clear to framing floor recess for atone arth 4"Diameter fresh air inMk from below on d of chimney N4 tSQ'to --5,_1 6„ro 4,_c / \ \ 1'-3 8"ref / / 3 8 ref oo oo i Wood burning stove to be Malm Zircon 34 color slate with matching finished porcelain chimney and positive damper to ceiling of 9'-0" height. Malm to provide custom fresh air intake box concealed in the conical base with 4" diameter on centerline of the the chimney above. Contact Kieth at Malm for details Wood Burning hove oo 707-523-7755. oo Chimney above ceiling to be Selkirk Ultratemp 8" ID with receptor for Malm / \ chimney, offset and custom chimney cap. o? o Wood Stove detail Kitchen I o 1' 2' 4' 8' c w cl 170105 4,_3 gn L4'-0" 4'-0"� 3'-1" _ 4„ • N r, r. • Io 34" .. - 2'8 3/8"R4 1 - 2'8 3/8"RO- W 1.O 34 M x I O 34„ 31-011 -31-011 o RO RO <t Fa '1~room _� 4'-3" r cl cl M 11' 10� .� I Lit I 10 prq o i 34" 'o„ ,0„ , 12�„ o o Dn Y Pantry 34" M \ I 8Q� mgr flO4 O 34" -�-3'-0" 2'-0"–�`-2' N RO iV N 312" Closet 1 „ 6�„ _ 3 3 4'_0" I 8 To _ t 3i a a o _ 8'-1 " 4 _ W cV cV r•1 � 1,-8y" 2'-11y2" 1'-9y2' N Family u " 15' 1 field 4 I 30" N Guest toilet w 15'-9Y2' _ _ — _j Up w 18'11 field" s a 18'-93 4, _ Bedroom -� Vestibule d 3'-l"--j 2'8 3/8"R RO M - 0 34„ New Cellar hatch -N a cl o 1 T 8%4" �– 7' Y4 8 " 3' 10%„ 3'-10%„--,� I I Veranda 0 r T 4' 8' N FA I First Floor N5 z„ 5Y2"++ 161219.1 i 4'-414”ro 'JAY. OfR'a�. Q4w,6y�fre► �{Mvi �e. y �yq✓ I Kevin Perry Architect rY@att.net kevinP er Alterations to 400 Iaing Street, Orient NY 212.727.9907 Construction Plan: First Floor March 28, 2017 I � I O I I I I I I I I I / I I / I I I \ I ( I Mister Bed loom \ I I I I I I I I 4 I • Up I Stair hall I Dn I � Sitting Room ID Bath 0 0 P 2' 4' 8' Second Floor 161219.2 k Kevin Perry Architect kevmperry@att.net Alterations to 400 Iaing Street, Orl* ent , Ny { 212.727.9907SDO03 Construction Plan; Second Floor June 20 2017 NS NS NS NS NS r— — — — — — — — — — — — — — — — — — — — — — -- r - - - - - - - - - - - - - - - - -� - Pocket I I ro\o D L _ J I I„ i �I 9'-11%2" I EW 1 EW1 I I I L - - - - - - -I I I � D I I I I I hl Ln New piers and footings I ' new foundations I F - 7 D I CL L _ J r M- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � I r- - r I 00 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - © I L _ J EW2 ( I L _ J r - -� - 7 EW2 El I I D I new crawl space — . L - J L J °O F1 I I : • I — I .. I I F 7 I I new crawl space FE I I •, I I I I Existing foundations Li cmu infill L - - - - - - - - - - - -1 - -1 I_ _ -1 f L ® I I01 I0I - -- - - - - - - - - - - - - L J F - -1 L - J Up Existing Cellar / Mechanical Equipment ( o L _ J L _ J f �T {may columns L — J L - J L — J - - - - - - - D N C Uaz F atch cmu infill 0 1' 2' 4' 8' New foundation in location of existing; I L L— F - 7 F 0 1 I D I I D Cellar Floor L — — — — — — — — — — - --- NS 1 —NS1 NS NS NS NS r P. 41 6804 Y I Kevin Perry Architect Alterations to400 KingStreet Orient NY kevinP rerY @att.net 212.727.9907 Construction Plan; Cellar ! SID 04 October 10, 2016 I I Skylights I I I I I I I I I 6dar Shingle Cedar Shingle lope 4:12 slope 4:12 - - - - - - - - — — — — 4-4- - � ° N Cedar Shingle Cedar Shingle slope 6 7/16:12 slope 6 7/16:12 0to _ --� N v M W r � � fn .. Cedar Shingl o I slope 3:12 v � I G 6 Modified eq M 66 C oo Bitumens � N Modified Bitumen _ o slope 1/4":12 a slope 1/2":12 M 00 a� bIJ N , �Cn 4-4 Modified Bitumen M slope 1/2":12 _ �° I odified Bitumen I II slope 1/2":12 I Modified Modified — — — — ` — — — — — Cedar Shingle Bitumen Bitumen slope 5:12 slope 1/4":12 slope 1/4":12 I I , I I Cedar Shingle L slope 3:12 ---- Cedar Shingle Existing slope 9 3/8":12 9a3t siting slope /4 12 Cedar Shingle Cedar Shingle Match existing slope Existing slope 9 3/8":12 9 3/4":12 Cedar Shingle Cedar Shingle Cedar Shingle match existing slope match exsiting slope xx:12 xx:12 Cedar Shingle slope 3:12 0 1' 2' 4' 8' Roof Plan 161219 7 t"s4 �e �sy I Kevin Perry Architect Alterations to 400 KingStreet Orient NY kevinperry@att.net 212.727.9907 • Construction Plan; Roof SD 40D 0 5 June 20, 2017 f i I i i Rear Addition 12 93/4 18'-1Y2" _o Side addition -� LL FF1FP [11 [:E FP FT] mm11 .1 Ll EI Aa Aa Aa Aa Aa ]Aa B -- Li --I i i Exsiting Garage Addition Existing Verandah North (Front) Elevation 0 1' 2' 4' 8' 12" 9 3/4"� i Lj LU LEIIIA 8'-4y8" top of wall fill [ III'l III I [ M ] Ill 1111 — ■ TTTT 1. 1 1 Verandah West Elevation 0 1' 2' 4' 8' i Kevin Perry Architect Alterations to 400 KingStreet Orient NY kevinperry@att.net 212.727.9907 Construction Plan; Elevations June 20 2017 12" 8 3/8" IF I I i i j I U 11j i Aa Aa Aa Aa Ab Ab Ab East Elevation 0 1' 2' 4' 8' 12 6 7/16"F i E 12"1/2° 12" 3"r— J IL j, L---J m m / \ Aa Aa Aa Aa Aa �DL \ 01/ �DL South (Rear) Elevation 4"1 0 1' 2' 4' 8' N� F' •: �s:Jji' A I Kevin Perry Architect evi Alterations to 400 Iain Street, Orient Y er kevinP rY@ att.net 212.727.9907 Elevations June 20, 2017 r---------i I I 12" 6 7/16"F 4 top of deck(low) -15'-1Y4" top of vall Mas er edroom q 12 12 3r— 3� 10'-2Y8" finished floor -- 12" 3"r— +7'-6 4.. d. underside of girder1'_8Y8" 4.. 5 4., Kitchen Living/ Dining Deck Living/Dining 01-01, -0'-6"-- finished porc i i j Section Al Section A i o r z' a' s' 0 1' T 4' 8' Ii j I j i i 4'-03/" 4 �- top of deck ow / \ 1 T-10l \ \ 12 � \ I I Iall Attic I r 1� �J i Attic 0 0 0@ 8 0 0 0 01 e Hall Family room edroo ri I � Pantry Stair Stair Hall Ald I ❑ I I � I F i I I I I I Library A I I i I I I I Section B ' 0 t' 2' 4' 11' B I I I I 1 I I I I -------------- Roof -------- —Roof Plan a 161219051084 Kevin Perry Architect Alterations to 400 IainStreet, Orient 'YNkevin er @att.net � , P rY 212.727.9907 Building Sec�ons June 20, 2017 Rectangle with 143 SI open are t1'-3" top of chimne _ N i 18'-0�2'–\ 1 Bedroom I Toilet 9y4" 8'-0%2" j 5 10-6 8" r I ' j 003'334„ ,-6" Hall B room Dining room Living room N Toliet cl. Stair 93 „ 4 c� 3 6' 2'-5y4"— 5/4 8$8 — — — — — — — — —111-83 4" 8'-lly4" Section D 12 risers 11 treads 4 riser 3 treads 0 1' 2' 4' 8' N t` t` �9 1'-0Y8-' Section D1 0 1' 2' 4' 8' ■ C1 C Di D1 Attic I 1 r1011 ❑ ❑ I i ------ ❑ ❑ 1:1 El Rafters with stacked 2"x mateaal"Eor slope I I 1 I R'-5y" I I I I I I F a mily ro Toilet Bedroom Bed room I I I I I i I :I I —-- I Section C 0 1' 2' 4' B' Section C1 0 1' 2' 4' 8' Roof PliI f�. 161219 Kevin Perry Architect Alterations to 400 X,-ing Street, Orient NY kevinperry@att.net 212.727.9907 Building Sections January 17, 2017 i � 1 l i NS 2 NS 3 NS 4 NS 5 NS 1 111111111111�11111111111�1111111 NS 1 III—III—III—III—III- 19'-11" 8'-611 -10% II—III—III—III T=III III—III—III—III=ITI- d — —� — 1T7= I I—III—III—I 11=1 I(L 11=1 11=1 11=1 I�--TI f=1 III=IT_I=T�I I— I I—I I i—III—III—III—III 11=1 ff—I f�i=�1� F.1 111=T=1 it! I—III— t o T_—I I—I 11=T—I I- 11=1 I I=111=1 I I=1 11=1 I I 1=11 =T—I 1 1=1 I I—I I I - - - - - - - - - - - - - - - - - - - - Q 11 MI11=111-111=111— ; 1=1I�T=III 11 — = a . 11-111—I 11=11 I-11 1=1 I I I I-1 11=1 11-1 11-1 11-1 -111=111=1 I El III - a I I I-III—I I I= l-1 11=T-I I-ITI- o I—III—III—III— I I—III—III—III I I—I 11=1 11=1 11=1 11=1 I I l — — — — — — — —\— — — — — — — —t I .I I_I=1 I 1=1 I I a III-T-1 11= 1 I I=1 I I-J I 1=1 -1 I—I 11=1 11—I I I= I I-1 11=1 11=1 I I I�I I —III—ll1=J-111 =� Pocket — — 4 . _ _ _ — I I NI I —I 11—I 11=11 I—III—I 1 I—I 11—i 11—III-1 I I-111—II I-= 11=1 I I — 11=1 11=1 11=T=1 =1( iiiii=iii= I-f_I I-1 I I-_ILI LI1—I_LI=1 1= °O I F.1 1=111-1[I I I— ° a I I � — I •. I 111 I I�I I II I II I II I I . I I I If I�I I II I II I I 1=1=1J 1=1 I I—I 11=1 11=111 1j 11=1 I I-1T I i II 11=1 I I 0 1 I i- - L — J I ++ . F- 1 Typical FoundationF-21 Yp Foundation I =N I 1 11 '-111 1+ I j F.1 close to grade o I 9 11/2 �2 EW 1 EW1 I ( (� I L - - - - - - _ p I Deck, itch 1" P L — J 33'-1Y411 I 11'-3%s++ I -N L " J I I Finish floor 1 st floor New piers and footi gs i 3 11 12-7/8 new foundations r CL I top, high deck L — J q I I I ( F'1 n — - - - - - - - - - - - - - - - F.1 I- - - I — C? I top, low deck - - - - - - - - � - - - - - - - - - - - - - - - - - - - - - - - - - L — J I I a = _ _ _ _ _ I I 1=1 11=1 11=1 11=1 1=1 I � � I I I — f1- r -� EW 2 III—I 11=1 11-1 I I—III—III—III—III—III—�11=1 -� L — J =1 11=1 11=1 11=1 I I-1 11=1 I I-1 11=1 11=1 I i-T- EW 2 M new crawl space L ❑ J L J 00 M N new crawl spaceFE I o I I— � Existing foundations �— — — — — —� - cmu infill F-3 Porch foundation F.1 L - - - - - - - - - - r -1 I- I- _ I F•3� ® I I I I ® I 4'-i L — J L _ J L _ J - - - - - - - - - - - - o F.1 00 ' r EW 3 Hinged portion of deck EW 3 L J Finish floor 1 st floor � � I 0 O L J Basement hatch Up 81.211 I Existing Cellar / Mechanical Equipment I I I I I � °O L — L _ J L — J 5'-6 g" 8" Lally columns \ I Ili _ I — I _ I _ I — I - 1 a ` V a. III—I top, low concrete wa =T-ITI-I I=ITI=11�1 — —__ -III=III_- -III=III= N [laz atch —III-111—II1=111-111—II III-1 1 1—)I I—III—III—)1I— N — J IF•4 M F 1 n III-Iii-IT_I-IT_I=_1TI-I _ Top, high concrete wall -T-111 1�1 i I—TTi= —III—IT_I-1 I I—I i I—III—I I I I—I I MI I I—I I I-- °° co F.1 a —III=1 I =1 I I—III—III—III — — — — — — J _� III-ITI=1 I f=T—I 11 I� I ; —II1�=ITI�=111�=1II�-1I cmu infill I I 111—I I I�—III—III-1 —I New foundation in 0 P 2' 4' 8' location of existing, — — I-111- - — ,- — -, — -� =1I11111i 1111=111=1I 7. _ 111—III—III-111-111-111= cV L ® J F.3 L —I d 11((11 II ITIII�1��-�1 Cellar Floor = L - - - - - - - - - - ° =MIT=III-III -11 I f 1 I I 1=1 11=1 11=1 11=1 11= F.2 7'-03/" 7'-03/" -IT-1=-111=-111111-I I I=11 1'-011 III—I I I—I I I—I 11=1 11=1 11= -111-1 T I-1 I I-1 T I-I T 1=r NS 1 NS 2 NS 3 NS 4 NS 5 NS 6 aIII=ITI=ITI=I—IJ--1T�T= M,�ITI-TM-111-� T=11 11 I II 11=1 —I 11=1 I I-1 I II 11=111-11 a a a Q III—II1=11=L=1_1_I=J_I= _ _ _ _ _ _ =1 I 1=1 I 1=1 I I—III—III—i I .; -• . _ _= I=1 = I = = 1= = I - — — —i i —I_I I—I I I—i 11= 1=11 I—I 1=1=1 1 1=1 I I-1 MI 1 I-111—I 11=111=1 11=111=1 1=11 d =111=1 1=1)11=�1 _ _ _ _ _ _ I-111—I 1—I I—�—I 1—�I�-111-111-1 11—III—III—III—I 11—III d 11� 11—�-111 '`�� 'wF" •a{ +`•� ' III—III—III—III—III—III—III—III—I 11=1 11=1 11=1 11=1 11=1 11=t I a 1=III—I__I I—III=III—III=III—ill—I 11=1 I I—III=1_I 1=111=III=III_ __ Hil _ =I I —III—I I—III- � 4"" ` '`' ' 111-111—I 1 I—III—III—III—I 11—)I I-111-111 111-11 —III—I 11-111 111-111-1= 1 f l—I I- 1 11 I-1 I .to �r ►' -J- - ll= -1-L1= . I-III-III-III-III-III-I 1 1-III-1 11-III-III-III III-III-III-III-1 III 11 till III 11 III III-III-III '�- S• F-4 Basement hatch 0:�1 Issued for field coordnaltlon. Kevin Perry Architect • Alterations to 400 KingStreet, Orient NY kevinperry@att.net 212.727.9907 Foundation Plan Issued for excavation December 4, 2016 NS NS NS NS NS 54 lvl stud each side of window. i r------- -------, t t Rafters with stacked 2"x material for slope EW 1 EW 1 tjt x 9 1/ 12"oc at sto e E:L�= Posts up NSA J.1.2 tjil x 11 7/8"@ 16"oc" O J.1.2 tji110 x 11 7/8"@ IG"o EW 2 M EW 2 N 00 t` t Ezsiting n ,-- Ne,e H adn ahn T-4 P�"' O1 b`Y �' Ezsiting attic T--4 CIA Bearing wall above Exietdng�1°g r.Rer J r� . F--� I I T exnimg ud uv When 11 New Exterior wall and I I roof rafters I I x rl �/'I I support New Bearing wall to 1. g.13 2lv @ 7/l " q�ua, Remove existing I I M f rt roof above P st up Post u o r•. roosection exterior wall and I I II II x I I New girder and footings 121 / i w� Bearing wall above I I a u" U New joists xsttm outs 00 o �1 0 PE New crawl space Ezsiting crawl apace Ezisting basement n TAIR -----1 1. .11;pl 51/4 x7" 52 vl for ub suf port 0 V 2' P 8' * 2 2x6 r posts from ove � t- Joists; 2x8@16"oc 2x8 ,.1 joists; 2x8@16"oc NS•2 a .a � � g x CIO71 (V (V .10; I LVL @ 1/4 0 vw o ty Jder: 2 Lvl 7 112" ..� o � N Bearing wall above —LLL eyistiny flo r j ists mN OO(j ()' i`-7� el OPEN c (9) B T TCH 11 11 LUB j1 11 I I Ewrcng When 0 1' 2' i N g 8--may Nes roroppott E:sitlttg as i 4 ed .. Joists; 2x8@16"oc Emd Macb�"� — +�6 Ezsiting attic enng w+g to �opport Fd N — atend mung bndag wa to above nnc floor t• E ttne roof When � ' vuppo I First Floor Framing i Enining wLng mhu ' Nev 6adn tt.eet ' aod toNev Roof Rfter ased I I I II I Remove ootriggen I I Cut back ashen pOH NS 1 NS 2 NS 3 NS 4 NS 5 ii i1 a' Note II II 1. Girders for the porch deck and roof,(plam)to be pressure treated Paralam plus PSL II II L t a �, ... Kevin Perry Architect Alterations to 400 1**,-ing Street, Orient NY er kevinP rY@ att.net 212.727.9907 First Floor framing Plan January 10, 2017 'a NS 1 NS 2 NS 3 NS 4 NS 5 20'-33/4" Docs dune>? NR*eNew roofnheoGird.we0 ro patbehindMaster bedroom en w-10' t Eaiadeg ceding nkcc RJ.1;2x10 @ 16"or RJ.1;2x10 @ 16"oe pan ung cdmg u[tea end 1 (V o n o n \ a Living dining o n X- RG.8; RJ.3: 2x10@ 16"oc a �a RJ.3: 2x]0@ 16"oc fi 2 @51/2 ii Post Alam 5 1/4 x 5 1 4" ost la 2 -----� 1 x 4 r_; r_, r i ----- L `--- 1--- `----- `---- O G2.1;31v116" I 0 t• T 4' g �o NSA 2.J.3 2X10 16"OC Da rha.e !I oo Ch-.y and— New not nAva Cn a .---t - Nw ridge beano > 2.J.2: tji 560 joists 117/8"@ 16"oc Skylight oP�g \ M V) See roof plan for framing N " 2"fit t&g structural deck Master bedroom \ X LW U Chimney e-. Poor ro edge b.— Nm �CC FN ��'� (nine m roof eh N—ridr�to.uppoe E�ehmg nften brbmd \ P4X4 P4X4 2G• 2L 111 2" a \ New gw.ro auppon \ .--t Bring w0 Post plain 5 1/4 x 5 1/4" `'� NS girds 41 poet for EW gimer Exter I exstir ceilin rafter Opti P°s�f.,NSW. Se7Gg Living dining 21v1 7 1 2 -t — I staNhaH isingw H 2.J.3 2X8 16"OC u abo i e p Shaun-inion ro e ease Post down V ley ab e 2 LVL@7 1/4" recces for erove heanh Post to uder ab ve G2.4 21v1 ,9 1 " Grder, P X4 [7 N `-----'' `--�-1-----a `-----� i 1 P st to va ey abov — — — I aotamma 1+gr 6" x 6" column '✓ 0 1' T 4' g• ' G2.5;21v1 Ca 11 1/F" o n P4X4 \ _ _ LGA;1 plam @ 5 1/4"x 5 1/4" Parti on belowNW.5 Ch'mney rr afntafn _ \ r gap to gird rs N 2.J.3 2X8 16"OC x _ 1 (V � f \ N i N Valle sabove R. 2.G.6; 3 LVL@7 1/4" k N d RG.8; 2 @5 1/2 T N 31"holes f 2.J.1a; 2X8 16"OC z sanitary line 3 2LVL 7 above floor 2 LVL@7 1/4"flush with floor 0 ]' 2' 4' 8' I I 2"fir t&g structural deck G2.1; 31v116" Second Floor Part Plan LVLS@';"under tub 44, \ / \ 1.G.2; plam @ 3 1/2"x 5 1/4" 2 "holes for drain 1 2"holes for h&C water �\ / i NS 1 NS 2 NS 3 NS 4 NS 5 I i I r 1 0 1' 2' 4' 8' - � Plan detail at chimney _ft�,, `vv.�.✓ J.h..�1. Kevin Perry Architect Alterations to 400 Ki* ngStreet Orient NY kevinperry@att.net 212.727.9907 Part Second Floor and Roof Framing Plan June 20, 2017 - ---- ---- ----- - - I I , I , NS 1 NS 2 NS 3 NS 4 NS 5 � bq-d it i Pm Gad.GYU --Gad.G.2.8 bryo°d Pon i Lower roof. See 16gond 2nd floor framing Gad.G2 plan. 7 1 EW 1 valley 2@2"x 10" 0 r r r e' �CA s EWA RGA 2 x 10 20'-3 3/4 C, c, 2 EW 2 O r n N N Roof nft. w U outriggers b ox x ,V"�O N 2'-8 rafter 2X10 @ 16"oc" rafter 2X10 @ 16"oc" 6i R°oE nh. O Post do srn«.1&a e'W.° Zoo:Oi� 0 ; a i P4 Roo[gird. Gad. I � x N cq Roo ra ters �P°n 2X6 @ 16"oc" 2 lvl 7112 2 X 6 outriggers RJ.5: 2X8"@ 16"oc" ? @� RJ.4: 6@10 "oc" N Po down ia" w H P4 y d Cut exisitng roof rafters a _ w O Post do 2 00 Post do Post do N r-L-1--i exi ting ri ge o @ 1 '0 1/ "vif dge r infor ment lvl@ 1/2" L----J Pc st do R.G. 3 rij eanj 21v1 9 1 0 1' 2' 4' 8' W 3+ G; roppe 1 lvl 9 1/ os do w r.«n n 4-4c- 4-i Lower roof. See 2nd floor O framing plan. Po own N w v w H O p N N H r�l 00 00 V X xa1 N y .p N 0.� d 2 x 8 roof rafters 0 1' 2' 4' 8' Roofs 160330.1 2 X 6 outriggers NS NS NS NS NS —1624 Kevin Perry Architect kevinperry@att.net Alterations to 400 1,*',*,-i* ngStreet, Orient NY 212.727.9907 Roof Framing Plan a ' June 20, 2017 ON081SYV8V ssvpnOa 30 New fence inside Zoning A0 d/N aNV' 3,g•� property line d/N ONVI M"0060Co 4 SS,9'Z ����� 3a��ls ,9 Ditrict: R-40 t S,s'o .�- Lot # 1000 26.2.14 ° °' ❑ g regulations R ❑ _ f: 0 1 STORY + CL Lot is a nonconforming lot bulk _ ____ N,g ° ' ` _ COTTAGE t 280-124 apply. The proposed Lot coverage ' 0 ;( � � _.. - � � ,•,���. £," ,��r,f� -- U ,� � �.,,�.:�:�'' •-"°�J;�-��`°�'° '; ', _ � exceeds the /2 ° o allowed. ,Z,s'' �< is�M t.$�,,'J�,..Y'1Q�1+ �r s✓:�/ X71 ,.,_,_ ;, '\ ` \ ..�,•° ' ,r''-.ff,,✓�' ; ,,''" f,•'� � •J��,,,/ 13�,J 1 "r,,r-i:`!t',X/y ,,` ''A.,e`f�. !moi 1 .'�•°/ /✓"//�F�,,r^,: //f 1 d0o1S ------ C4 d. oNoo 0 •d•n - Lot Coverage exsiting proposed 10-0 Grade Patio q, accesory cottage 418 SF 418 SF ❑ p rri Nezv Fool M ; m m ° 1 3 -- --- garage d s 695 SF 695 SF c� -� $'x 3t' �\ an shed c� j i z m m -' house 1,841 SF 2,414 SF porch - SF 249 SF i zoo-o" p � € ° side pard deck Q iSF j \,, •. ' Side par - m — — SF to 5'm b i .,� ri _ ; d °;LtiSi urrl rn M`,�.� _. . ° 3 ax combined � � Y't � � ., ' 1 Existing ' 4 \` ° pool 1 o 5� --{{ septic system i �, p - sf 648 SF ✓ �'lr.'. —i to remain \ z i ` Vii" total ,954 SF 4 424 SF G� ,Ettstln e'' ! 2 -�. r Shea' f`,, IS" 201-5 s m a f. ,'-.`, f _._ . _. 'f;" . ✓ ,`,' / ---------- lot area 20,414 SF 2 M,s o �, ❑ _ ❑ 14 SF ° :. ,. 0 4 i "� t-"�,.j�f''/ °✓r jd/'''•J/' '• `.f J•�'a • ✓ Y b'O °iN213 00" J '''k' is ing, Exisitinn removed oved � Vie'' , r proposed lot coverage 14.47% 21 .67% •° ','•:' , s :>f. ',f ,/ Patio<n grade New Fence/ P Q A• 's`F�'%'`�r� V.�• ."t"•' rf!: r'F,ril,. "J' ,° Gate _ '� Addition j 7 83MOHS NO2ldb' 'ON00 011dd � ,� N000ino �� j Pool notes • , j 'tii J' , 0.' 1 Install dewateri g dry well lag n t Cf) ;w �X >IIVM >1018a , ,: 'V? 2��130 ,s'� _ ! 'n large enough o CO ( 4 3! ----- X .`,, .:r N accommodate discharge of pool water. !;33N33 3811 ;f f Z ' "' f r %j equipment e placed in proof W ' `f f a9� ;``'�; :f,, ''i d°Noy f/ / 2. Poole ui ment to b a sound 18'-3" New Fence/Gate';% n",<J�r✓ °F ',' ' , /, - structure. 71 7:1 co ! ' r-. Cir, °` ;': `°r:. ' ' ;' ,ON1�3 MCI`' W?� '/:�' ° 0 /� / ✓f } �` it / ''' :f' f r` f. J ,�/l, �'" '' / f��~�°.✓',;' O C �^v 0 . / 4-4 Oi Q x �� e"t(' £'r/ fJ tl` l � Jr nJ Q f f f ExISt1II DUSe Remain ,' I C 1 F J'✓' ` Q �'' f� ! -Isiting emov d CQ Uj �`� �✓•>L iI "`fl�QQd,`'' .*`F r' ,'r6°,"' S,9'U7 —� �xf1�j � ,r ... j _ Iv 1✓ i!J_•;,..r C132 /�00' .f,!�.�..L�.�J,. 3,2.0 Picket Fence L-- -- J v OF_ — — E, Nid NO2I1 j D 1 d.n 1 ! N08dV 'x18 '013e I! 71VM 83SM11 _ KING S T RT DING STREYET (' _� ,- .13 fl�Yt k i f "`,1 1 - • { -1,i i[:1 ice' -P 1" f` I'1-1 L; 1N3W3Add .40 30 ry":.l `CP '- e�:tl ar _ .° a► Existing Site Plan 4'�, a.,. ,- - Uu—f Proposed Site PlanE; ,Y Survey data taken from survey prepared by Ken 20,41 4.25 SQ.FT. Or 0.47 ACRES Cl Woychuck dated 09/28/2015. Trees and bed CORRECTED LOT AREA D9-28- 15 PLUMBER CERTIF1cA7rxj ON LEAD CONTENT BEFD,'7E' TRUS,S P J locations added and are approximate. GES IFICATE OF OCCUPANCY �C��DIN� One Story Addition i'��_9FP USED IN WATiER �7UFF1 Y SYSTEM CANIWOT EXCEED 2110 OF I%LEAD. J T\vo story rear addition Two Story Extension \\`\.`, ::. t r Extend Porch Gable roofPLUMBING \ � Remove two story rear addition One Story Addition r `; \ /f' F-1,",1P �TT °'AFF (',� v I UC.:v 11 Lit l°, t• F TER 236 ' ;r` a PJR�U,�f'.T TO CHAPTER ;\ Or THE TO�dfd CODE. _ r � \. ..\ \\\ •\ \'� \ ,. \\ "1: tom, � Two Story living spaceLi Stor<=Addition \,\ y'.J Original Salt Box Low flat roof \\` One Story w/attic 1 contemporary addition ._J \' �¢ A RC�� One Story Enclosed and enlarged porch i Reconstruct as Open Porch I s Approximate line of 1920's porch Remove porch extension 02 Existing Removals Proposed Kevin Perry Architect Alterations to 400 14*,ingStreet, Orient NY kevinperry@att.net 212.727.9907 Site Plan b Revised October 512016 to corn I-V with ZBA resolution #6961 Living / Dining Kitchen Wood Burning stove It Bedroom Family.room --- - j' D Pantry o - _ ...... .__ ..... . .. ...__ .._.. ...= - Toilet Closet New Cellar hatch n o o ❑ Family Guest toilet U2 _ _ - LI Entry Bedroom Vestibule -- '� ❑ o 11 4, a Veranda First Floor El El 161011 A i-?C 021 Kevin Perry Architect kevinperry@a�tt.net Alterations to 400 K-ing Street, Orient NY 212.727.9907 Construction Plan: First Floor SDGO ?j October 10, 2016 s' - - - — — — — Master Bed room 11 Up U Attic Bath i Dn o v w--- Sitting Room o 12' a' a' Second Floor 161011.1 RE ARC X/ P Rnj, �C' a' _ t 4 02A��� Kevin Perry Architect kevinperry@att.net Alterations to 400 Kin Street Orient NY 212.727.9907 Construction Plan; Second Floor SDO03 October 10, 2016 C / SD909 D - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - L - -J - - ---- - - - - - - - - - - - - - -L — J I I I r I I L — J New piers and footingsF L_ — — — — — — — 77- I I ❑ I I ❑ ❑ ' I r- - - - - - - - - -� I I L - -1 L — J L — J I I I I new foundations I r — I I I C70 I ❑ I 1 L -� i I • I rr - - - - - - - - - - - - - - - - - - - - - - - I ❑ I I 1 J , I new crawl space I !_ — J I _ r — 7 II I !� new crawls ace r I ElI I p I ❑ I LJ I :. ., s , I ❑ I I L _ _J Existing foundations I rr _ � — cmu infill ►- - — — — r r I ❑ I I i 1 Q 1 New Cellar Hatch 1 11 column f ` J L _ J L — J — ew a y co u and footings L - - - - - - - - - - - - - I O I l o I II existing crawl space f. I I r, exsiting lally column I O O I 1 Up I Existing Cellar / Mechanical Equipment r -1 r — _1 I 1 0 1 1 0 1 new crawl spacel L — J L — I cmu infill I 1 I U 1' T 4' 8' - _ - ..T.. - .,._. - _ _... - - - Cellar Floor — — — — — — — — — — — — — J "I ` 021AQN yOQ N Kevin Perry Architect kevin er att.net Alterations to 400 KingStreet Orient NY p �@ 212.727. 907 Construction Plan,• Cellar SD1004 October 10, 2016 Cedar Shingle Cedar Shingle slope xx:12 slope xx:12 -� 4 UN - Cedar Shingle Cedar Shingle slope x:12 slope xx:12 No Cedar Shing l slope xx:12 o o o i ie 1-4 bBen NN sloxx: 2Modifed Bitumen X slope 1/2":12 � o � Modified Bitumen slope 1/2":12 No0 U 4-4 odified Bitume slope 1/2":12 Cedar Shingle Modified slope xx:12 fied Modified - Bitumen Bitumen slope xx:12 slope xx:12 Cedar Shingle slope 3:12 xx:12 -� Cedar Shingle � Existing slope Existing slope xx:12 U Cedar Shingle Cedar Shingle Cedar Shingle Existing slope xx:12 Existing slope .x:12 Cedar Shingle Cedar Shingle Existing slope Existing slope xx:12 xx:12 Cedar Shingle slope xx:12 0 1' 2' 4' 8' Roof Plan 160127.2 PE ARC p- 2� A F OF NFA Kevin Perry _Architect Alterations to 400 KingStreet Orient NY kevinperry@att.net � 212.727.9907 Construction Plan; Roof SDO05 October 10, 2016 i w. ,! Rear Addition i ;Lf Side addition — _..___,....._.._..._.....---_.__._._____ -------------- _ _ . } .. I ... .... ... ... . . ..... ..,.. .. ... PIMMM t ...... ' y I a . ...... ....... .... . .......... r,£ ___. ; .......... Exsiting Garage Addition Existing Verandah North (Front) Elevation 0 1' 2' 4' 8' w AV El .... _ ............... Ell -_ _- j I I I I 0 9 3 Verandah West Elevation 0 1' 2' 4' 8' ?,Eo AR Cy 1 0. 211 -L _ F OF NET Kevin Perry Architect Alterations to 400 1--*,-i* ngStreet Dtient NY kevinperry@att.net '7-7 212.727.9907 Construction Plan; Elevations October 10, 2016 201-3Y4 11 , 17 -10/8 .. . .. . __._. IN , , ......................................................G.., .. ... 1 \ ' i , I i ....,. ....�.............. »....... . ..._......:..,:,..,.................................,_. .............. .. ............ .. .. , ....... �... ....�...._.,.. ......�._....,..... ..... ,... .. ...._.. I . . ...�. .. .,.. ... I t --------------- f O .....tom.,....-....' ..�.............. 4. » 4..v I i I j 3 S i x v i i i S i , I � i _ j i 4 I i ---- East Elevation 0 1' 2' 4' 8' , _. 12" 12" = �1 2.. I I , I South (Rear) Elevation 0 1' 2 4' 8' 0211i)N �n OF NE�'�� Kevin Perry Architect Alterations to 400 1<ingStreet Orient NY kevinperry@att.net: 212.727.9907 _ Elevations 0 April 1 , 2016 ---------- _ l,.,,'/.'; `�'. `rte-,.. NF7 _........., -- ....._....._ --_ _ fie, _ - - - - -- Raster bedroom 12 E ......... . ......... ... .... .. .. .......... ........... ---------- ... -——--------- --------- .............. -----------—--—----—------——------ 1z z z Verandah Kitchen Uving Dining z Deck z North (Front) Elevation 0 11 2' 4' 8. ................................... ............................... _..w._....-- ------ ................ ............... ......— 12 ---- —,4 714 Attic Closet Attic --A r Stair Hall li L brary Hall Family room I Bedroo Veranda Pantry T A Section B 0 1' 2' B A 9C�'4 41 PL X � Roof Plan 160127.2 Kevin Perry Architect Alterations to 40 0 Iaing S treet Orient NY kevinperry@att.net 212.727.9907 Building Sections April 1 , 2016 i j : . Attic - I - - .......,.,... ...,,.,,,.....,., , F •ly roc Toilet Bedroom Section C E 0 1 2' 4' - Terrace Bedroom Sitting room h �: � E 1 C D LL Hall Bedroom !__ . iI ij' `� Dining room Living room i Section D 0 1' 2' 4' S' �aED AR Roof Ma •Ctt.. ��+ 160127.2 J_ i 0 r N Kevin Perry Architect Alterations to 400 1�'*,-:ingStreet Orient NY kevinperry@att.net 212.727.9907 Building Sections April 1 , 2016 _..,_. a:• .:r V-5Y n 1 1/2 structural fir decking half round gutter New Lv1 header under existir g Vent plate f` Lvl header Painted wood fascia boards � " 4< Window cap with drip ,� .` _., ., .— ��,,`: w;�a ,::�^t�r-��= f�� s,�•, New Lvl header copper lined box gutter 77 •/x".=��' �1. i' Ii E i f Pt .(f. f4� �.1 / + I I 3� i P^ .� :r.=i J• I i. r. .'1 ',:': ',.•%'.��- _fit ,'J�+�.�•P•l•' r.jf%, f�.lJ1}'r7 �f7 :.rfr J✓ ` � •f 1 5" Window trim Column and capitol beyond Copper lined box gutter 1" x 2" Painted fir, stick arch. 1 Eave Detail Front Elevation 2 Eave Detail East Additon3 / Eave Detail Porch 3 11 11_011 11 3 11-011 If 1 11 3 1 -0 7" muntin , . ,, ., • "` g A mock up of all trim details shall be constructed and reviewed by the owner 2" Thick Historical sill prior to begining full application of trim. r iz z _.. 2/SD. 10 _ i. _ /r + 2/SD.10 E� r 5/4" x 4 painted trim 2/SD. 10 Typical Window Sill DetailTypical •Plan Detail 11 11 11 � �< � 3 11-0 3 11-011 {� -� Roof Plan 1601272 cn Q j 1 /SD. 10 3/SD. 1:0 of NES Kevin Perry .Architect Alterations to 400 14*,-i* ngStreet Orient NY kevinperry@att.net 212.727.9907 Exterior Details June 9, 2016 -----_----- remove structure; roof, deck walls - and footings. I I emove structure, roof and foundations I� I I I I --� I I I _ I /remove exiting cellar stair I I ( J I �--� I `•I, � I i i IJ I ! i II II I IJ II I IJ ! ",,,remove abandoned chimney L - oundation I L� I ! remove toilet f es ! _= -------- L4 I I ! I I ! I I I remove roof, existing s e below to remain. I _ r 4 r/ emove exisiting stair. /remove structure; roof, deck walls � e ! I r .� II I I Cellar Floor ! I ___ _ and footings. I (---_ I ! Second Floor I --,.,- I LL_J I I rremove structure, roof ! I ! I and foundations ! J ! I L---------------- -------------- remove structure; roof, deck walls - - and footings. A__-.--remove structure; roof, deck walls I I I IJ I and footings. II III. ll 11 remove roof, existing I` structure below to remain. \— II I ! Iic== I I ! remove toilet fixtures I I ! ( ! I ! I I I I I I remove walls as show ! I -� --- Idoors, and casewoLi r-. �� - IN I j ra I Ir I II I selective removal of roof I III I ! framing see structural drawings I III J I II I remove toilet fixtures I I III _ �-i_-1_j ! __ — remove structure; roof, deck walls and footings. U J `�.� '...-remove structure; roof, deck walls and footings. `` 1111 emove windows. 2' 4' First Floor _-I `` III remove roof, existing L I �- � R r ` ,` I Lu`jl oof Plan structure below to remain. C , t \ 2 A -1 Scheinatic drawing issue for budget: Not for contsruction FN Kevin Perry Architect Alterations to 400 KingStreet Orient NY kevinperry@att.net 212.727.9907 Demoltion May 10, 2016 ..., -------------------------- _� --- d Existing Loam Soil 1-011 ;J. Inlet maintain 1/4" per foot pitch min from leader -' ❑ Existing 1 story cn O --- ry Clean out hatch -- o ` cottage i IT _ =,t New Dryw _---- ---- / f` ✓`' •r'' \`\ �, i ,, t ,r� ;.i.: �;�.1: _ I.� ,. �: ell i j, l d ✓ ✓ r� d I t, 3 , , t � _�. � f` � .r,v \ •}�--•--,« a....iYdmin..e.......___.,....'r.S'`�y,' .., , i `\\\ `\\` ,, %.' r f r� � r•/ \, ri._.c. h_:. - J`'�.. .t.l!.-.:.l,t ,✓�, ✓ ,�' ' ✓ ,.' = = - i 1z New clean sand I `r/;✓ �' +' iF, Existing permeable soil Zn _:'. ,.` Id '---'_'"__ 1 3 •d•n New drywell for pool overflow + I„ I ! / Water level New Pool r I 18' x 36' : i i i Existing 1 Typical drywell septic system Side yard to remain \`\\Minimum I ;- ❑ 3 , ✓r Notes sE sting,-./ " f- / f , \ j ,shed /✓f`r' 1 . All drainage structures are to be a minimum of 20 feet from the leeching pi I ° ' ` ` ,✓ of the septic sstem. ❑ 2. Drainage calculations. yr Roof area 2 663 SF with 2 holding — capacity-443 CF capacity required Eris inf r,." ' - Each 8 x 10 ring provides 250 CF x 2-500 �T , g p CF provided. ,ire f L)` / ''.✓ , Ga' ge ✓ :f✓ j F 3. Maintain existing ravel drive way for silt and mud control. Addition �,, 4. Provide filter fabric at base of fences in areas of excavation to control silt run , I ! off.€ New 8' dia x 5' high drywell I I , I , I , , U4-4 f O �+-+ ----Existing House t Remain 4 f Picket Fence New 8' dia x 5' high drywell ------------ KINOU STREET Proposed Site Plan r4. OF E Kevin Perry Architect Alterations to 400 1*'.*,-i* ngStreet, Orient NY kevinperry@att.net 212.727.9907 Site Water Managment October 11 , 2016 C SD • 09 D SD • 09 .......................... ........... ....... ---—-—-—-- O --------- -------- iL-------- -------- ----------- ---—-—-—- -—-—-—- tji 9 1Y2 @ 16 oc cone pier and footing 6 01 -——————— — ------ ———————— C) i4 -j� L --------------- -—-—-—-- ------- tji x1 1/-2'—' @1619 ocit — — tji x117/8@1611 oc —— ————— ——— ------- —------ jiI I ( ( ( I ( V 0 IlI I I _ _ _— ..........—————— ------- u 00 -——————— —————— ———————— ——————————————— C) -T, ----------L 2 IVI @ \Ne w 1 el bin or lall, column! n ade rs at stat /e-x.ui ting lally columns-, 7 1 ext S ting wf E teel m tji x 117/8 @ 16" ocil Cut eN istin ste 21 br-i at tair —————— 4.J 0 0 ev,-,,teel bm on laRy columns 0 11 2' 4' Cellar Floor l rJ 1 �`�\`F, )F N rl 021�' dor budgetio Not for contsructionchei-natic design drawing issue f Kevin Perry Architect Alterations to 400 King Street Orient NY kcvinperry@att.net 212.727.9907 First Floor framing Plan S002 May 10, 2016 C SD . 09 DSD . 09 tow ?10'-2"? M MIMI - --------------- ----------------- . ..............\ f v-1-2-C7, 117/8 d tow B ------- AC6—ny Balcony i Wall I V - on deck top of deck @ ?? - _ i ------ knee wall _ _ ( - - 1.11 - tow ?13'-61/2"? double up joists tow ?. out-riggers Column ;p= —3Gq) 1-17/8 dp .z 2 x 10 @ 16" oc 00 - ------------ Ozz -- I II— --II - - - / 00 M 1 @ ? dp" II -ff 4�- -—-—-—-—-—-—-—-—--- - 1� i I i -- z: M tow ?? 2 x 10-111 V--4 IL@16 oc tji joists @ 16 oc -—-—-—-—-—-—-—-—-- lv1 1@ ? dp ------- --------- @) @ 16 oc outriggers 0 rigg ------------- I ( I I ( N top of deck @ ?10'-2"? N N 0 0 II II II _ _ 2 l 1 �zJVZZ22, I I I I I I I I II I I I lI Iv1 @ 7.5_ _ 11 h 6 x 6" Column I C) 1 -J 11 It 0 top of deck @ ?17'-8 1/2 ivi 1 @ ? dp lVi Q) 4-1 -87 1v18 1/2 on knee wall tob @ +8'11 1/4 1A 2 x 6 @ 16" oc" 1A 8 1/2 set on ceiling rafters (a) -4-71 91 1 41 V 6n - top of deck @ ?? � � ! � (I ems` 2 - -' � existing framing to remain ex istin rid4e tc p Ca ? 1 E T-1 1/2"', 1@7.5" h 1A1 @ ? dp 1A8 1/211 .. ...... Z'sting rid to @ ? 18-1 1 /2" II I toplof dl ck ? -911. tie existing framing to new he �r 14-4II V 2 z 7,4 1:1161�1 1 1 II II 0 II II 1A 1 @ ? dp II7� II Ua existing framing to remain = @ ? dpl, I � of �` II 0 V 2' 4' 81 0 4' 8. Second Floor Part Plan Roofs 160330.1 160330.1 C) (S) -0 S ce:m.aticesln rawing issue or bud et0 Not for construction hd * gdff, =- -� Kevin Perry Architect Alterations to 400 Iaing ,StreetOrient NY kevinperry@att.net 212.727.9907 Part Second Floor and Roof Framing Plan May 10, 2016 WIND FRAMING NOTES NAILING SCHEDULE PLAN CONTENTS: GENERAL NOTES 1). RIDGE-TO-RAFTER ASSEMBLY: ROOF FRAMING: OCCUPANCY CLASSIFICATION -_R3 RESIDENTIAL 1-114"x 20 gauge strap shall be attached to each pair of rafters in accordance to table 3.4. JOINT DESCRIPTION NAIL NAIL NOTES BUILDING USE RESIDENTIAL DWELLING When a collar fie is used in leu of a ridge strap,the number of 10d common nails required QTY. SPACING CONSTRUCTION NOTES: in each end of the collar tie need not exceed the tabulated number of 8d nails in the strap, RAFTER TO 8'WALL:3-8d COMMON EACH, TOE-NAIL BUILDING HEIGHT (SEE PLANS) 1).The information within this set of construction documents is related to basic design 2). RAFTER-TO-WALL ASSEMBLY: TOP PLATE 10*WALL:4-8d COMMON RAFTER TOTAL SQ. FT. OF CONSTRUCTION (SEE PLANS) intent and framing details.They are intended as a construction aid,not a substitute Lateral framing and shear wall connections for rafter,ceiling or truss to top plate shall be in CEILING JOIST 8'WALL:3-8d COMMON EACH TOE-NAIL for generally accepted good building practice and compliance with current New York accordance to table 3.3.When a rafter or truss do not fall in line with studs below,rafters TO TOP PLATE 10 WALL:4-8d COMMON JOIST PRESCRIPTIVE AS PER N.Y.S. RESIDENTIAL CONSTRUCTION CODE AND State building codes.The General Contractor is responsible for providing standard or trusses shall be attached to the wall top plate and the wall top plate shall be attached to CEILING JOIST TO AS PER TABLE 3.7 EACH FACE DESIGN CRITERIA 3E. 2006 SBC HIGH WIND EDITION. WOOD FRAME CONSTRUCTION MANUAL construction details and procedures to ensure a professionally finished, structurally the to the wall stud with uplift connections. Roofs overhanging the rake side of the building PARALLEL RAFTER WFCM-SBC LAP NAIL sound and a weatherproof completed product. shall be connected with uplift connections in accordance with table 3.3c. CEILING JOIST LAPS AS PER TABLE 3.7 EACH FACE FRAMING ELEMENTS AS PER FLOOR PLANS, CROSS SECTION AND GENERAL NOTES 2).The General Contractor is responsible for ensuring that all work and construction 3).WALL-TO-WALL ASSEMBLY: OVER PARTITION WFCM -SBC LAP NAIL EXT. BALCONIES 60 meets current federal,state,county and local codes,ordinances and regulations,etc. Wall studs above and studs below a floor level shall be attached with uplift connections in COLLAR TIE AS PER TABLE 3.4 EACH FACE DECKS 40 TO RAFTER WFCM-SBC if These codes are to be considered as part of the specifications for this building and accordance with table 3.3b.When wall studs above do not fall in line with studs below,the END NAIL ATTICS w/o STORAGE 10 should be adhered to even if in variance with the plan. studs shall be attached to a common member in the floor assembly with uplift connectors in BLOCKING 2-8d COMMON EACH TOE ATTICS w/ STORAGE 20 accordance with table 3.3. TO RAFTER END NAIL DESIGN LOAD CALCULATIONS ROOF (GROUND SNOW LOAD) 20 3). Dimensions shall take precedent over scaled drawings. RIM BOARD EACH END (LIVE LOADS PSF) (00 NOT SCALE DRAWINGS), 4).WALL ASSEMBLY TO FOUNDATION: TO RAFTER 2-16d COMMON ENDI NAIL ROOMS (OTHER THAN SLEEPING) 40 First wall studs shall be connected to the foundation,sill plate,or bottom plate with uplift ROOMS (SLEEPING) 30 4).The designer has not been engaged for construction supervision and assumes no connectors.Steel straps shall have a minimum embedment of 7 inches in concrete WALL FRAMING: STAIRS 40 responsibility for construction coordinating with these plans, nor responsibility for foundation and slab-on-grade, 15 inches in masonry block foundations,or lapped under NAIL NAIL construction means, methods,techniques,sequences,or procedures,or for safety the plate and nailed in accordance with table 3.3b.When steel straps are lapped under the JOINT DESCRIPTION QTY. SPACING NOTES GAURDRAILS ANY DIRECTION) 200 precautions and programs in connection with the work.There are no warranties for a bottom plate,3 inch square washes shall be used with the anchor bolts.Anchor bolt EXPOSURE CATAGORY (DESIGNED FOR CAT. C) specific use expressed or implied in the use of these plans. spacing is to be spaced and sized in accordance to table 3.2a. In addition to spacing, TOP PLATE To 2-16d COMMON PER FACE NAIL anchor baits are to be spaced between 6-12 inches from the end of a sill plate and all TOP PLATE FOOT SEE NOTE: I LOAD PATH SEE CONSTRUCTION ANDWIND PATH CONNECTION ) 5). Refer to the Window and Door schedule for exterior openings. comers. TOP PLATES AT 4-16d COMMON JOINTS FACE (ROOF - FOUNDATION DETAIL PAGE & GENERAL NOTE PAGE 6).The General Contractor is to ensure that masonry or prefabracted fireplaces meets 5).TYPE I EXTERIOR SHEARWALL CONNECTIONS: INTERSECTIONS EA.SIDE NAIL NAILING SCHEQULE SEE GENERAL NO IE PAGE or exceeds manufacture's specifications and applicable codes. Type I exterior shear walls with a minimum of 7116 inch wood structural panel on the exterior STUD TO 2-16d COMMON 24" FACE EGRESS, SEE FLOOR PLANS, AND WINDOW SCHEDULE attached With 8d common nails at 6"o.c.at the panel edges and 12"o.c. in the field, and STUD O.C. NAIL FIRE PROTECTION sym." 7).The General Contractor is to consult with the owner for all built-in items 1/2 inch gypsum wallboard on the interior attached with 5d cooler nails at 7"o.c.at panel HEADER TO 16d COMMON 16"O,C. FACE (SMOKE & CO2 DETECTORS) SEE FLOOR PLANS such as bookcases,shelving,pantry,closets,trims,etc. edges and 10 o.c.in the field shall be in accordance with the length requirements specified HEADER ALONG EDGES NAIL in table 3.15a-b, TOP OR BOTTOM 2- 16d COMMON PER 2x4 STUD END TRUSS DESIQN N/6 - STANDARD --STICK ERAM E QQNS]EUCTI ON 8).Wind load requirements shall be taken into account during construction. 6).TYPE 11 EXTERIOR SHEARWALL CONNECTIONS: PLATE TO STUD 3- 16d COMMON PER 2x6 STUD NAIL ENERGY CALCULATIONS RESCHECK FOUNDATION NOTES: Type 11 exterior shearwalls shall meet the requirements of table 3.15a-b times the appropriate BOTTOM PLATE TO: PER FACE NAIL I length adjustment factors in table 3.16. FLOOR JOIST,BAND JOIST, 12- 16d COMMON FOOT SEE NOTE: 1,2 CLIMATIC & GEOGRAPHIC DESIGN CRITERIA 1),The General Contractor and Mason to review plans,elevations,details and notes to END JOIST OR BLOCKING GROUND WIND SEISMIC FROST WINTER ICESHIELD determine Intended heights of finished floor(s)above typical grade. 7). INTERIOR SHEARWALL CONNECTIONS: FLOOR FRAMING: SNOW SPEED DESIGN �WEATHERING LINE TERMITE DECAY DESIGN UNDERLAYMENT FLOOD HAZARDS Allowable sidewall lengths provided in table 3.14 shall be permitted to be increased when NAIL NAIL LOAD (MPH) CATEGORY IDEPTH TEMP. REQUIRED 2).All footings to rest on undisturbed(virgin)soil. interior shearwalls are used. Sheathing and connections shall be in accordance with JOINT DESCRIPTION QTY. SPACING NOTES MODERATE SLIGHT TO 1 3). Provide 1/2"expansion joint material between concrete slabs and abutting 2.4.4,2 and 2.2.4 respectively. JOIST TO: 4-8d COMMON PER TOE 20 LBS. 120 B SEVERE 3 FT. ' TO HEAVY . MODERATE,, 11 NONE concrete or masonry walls occuring In exterior or unheated Interior areas. 8). CONNECTIONS AROUND EXTERIOR WALL OPENINGS: SILL,TOP PLATE OR GIRDER JOIST NAIL ROOF SHEATHING REQUIREMENTS FOR WIND LOADS: 4).Any new concrete walls being attached to existing concrete structure shall Header and/or girder connections shall be attached with uplift connections in accordance BRIDGING 2-8d COMMON EACH TOE be installed with#5 re-bar, 18"long at 12"o.c..Use approved epoxy for installation. SHEATHING LOCATION NAIL SPACING NAIL SPACING AT INTERMEDIATE with table 3.5.Window sill plates shall be have steel connectors in accordance with table TO JOIST END NAIL NOTES 3.5. BLOCKING EACH TOE AT PANEL EDGES SUPPORTS IN THE PANEL FIELD 5). Unless otherwise noted,all slabs on grade to be 2500 p.s.i..Concrete to be 9).CATHEDRAL CEILING ASSEMBLY: TO JOIST 2-8d COMMON END NAIL 4'PERIMETER EDGE ZONE 8d COMMON @ 6-O.C, 8d COMMON @ 6-O.C. SEE NOTES: 1,3 poured on 4 inch thick sand or gravel fill with 6x6 wire mesh reinforcing. Interior slabs to be minimum 3-1/2 inch thick.All fill to be compacted to 95%relative density with Where a ridge is to be used as a structural beam,the rafters shall either be notched and BLOCKING TO: 3-16d COMMON EACH TOE INTERIOR ZONE 8d COMMON 0,6-O.C. 8d COMMON @ 12"O.C. SEE NOTES: I (BOTH FIELDS) 6"maximum lifts(layers). anchored on top of the beam or slope connectors shall be attached to each rafter-to-ridge SILL OR TOP PLATE BLOCK NAIL I NOTE:.2 FOR PANEL FIELD 6). Crawl spaces to be provided with a minimum 18"x24"access opening. Install one along the open ceiling part of the building.Connections to the ridge and wall shall be be LEDGER STRIP 3- 16d COMMON EACH FACE GABLE ENDWALL RAKE AND RAKE TRUSS 8d COMMON 0 4'O.C. 8d COMMON @ 4'O.C. SEE NOTES., 1,3 8x16 cast iron foundation vent for every 150 sq.ft.of area. attached with the above requirements. TO BEAM JOIST NAIL DECK AND COVERED PORCH NOTES: JOIST ON LEDGER 3-8d COMMON PER TOE NOTES 7). Dampproof exterior of foundation with bituminous coating as per section R406 of TO BEAM JOIST NAIL THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY, N.Y.S.Residential Construction Code.A 6-mil polyethylene film shall be applied over 1). Unless otherwise noted,all framing material to be#1 ACO pressure treated lumber. BAND JOIST 3-16d COMMON PER END the below grade portion of exterior walls prior to backfilling. All fasteners,hangers and anchors to be galvinized or stainless steel. TO JOIST JOIST NAIL 1). For roof sheathing within 4 feet of the perimeter edge of the roof,including 4 feet on each side of the roof peak, 8). Drainage as per section 8405 of N.Y.S.Residential Construction Code. 2). Girders for deck joists to be bolted to each post with washers and nuts. BAND JOIST TO; 2-16d COMMON PER TOE NAIL the 4 foot perimeter edge zone attachments required shall be used. Girders on concrete piers shall be anchored with proper steel connectors anchored F SILL OR TOP PLATE I FOOT PEE NOTE: 1 2).Tabulated 12 inch o.c. nail spacing assumes sheathing attached to rafter/truss framing members with G>0.49. FRAMING NOTES into concrete with a minimum 112"dia x 7"long anchor bolt with washers and nuts, ROOF SHEATHING: For framing members with<0.42<G<0.49,the nail spacing shall be reduced to 6 inches o.c. 1).All framing techniques and methods as prescriptive design of 2006 SBC High Wind 3).Posts supporting girders shall be anchored to a 12"x12"xl 2"thick concrete footing. JOINT DESCRIPTION NAIL NAIL Edition Wood Framing Construction Manual. Use a minimum 1/2"dia x 8"long anchor bo�twith washers and nuts. Footings Shall be 3 ft. QTY. SPACING 3).Tabulated 4 inch o.c. nail spacing assumes sheathing to rafter/truss framing members with G>0.49.For below grade. Porches with covered roofs shall have 12"dia.concrete piers for the girders. STRUCTURAL 8d AS PER TABLE 3.8 framing members with OA2<G<OA9,the nail spacing shall be reduced to 3 inches o.c. 2). Unless otherwise noted,all framing and structural wood material to be#2+BTR. WFCM-SBC WALL SHEATHING REQUIREMENTS FOR WIND LOADS: Douglas Fir. 4). Deck joists to have blocking at 8'0 o.c.. CEILING SHEATHING: SHEATHING LOCATION NAIL SPACING NAIL SPACING AT INTERMEDIATE NOTES 3). Floors,walls,ceilings and rafters to be spaced at 16 inches o.c.unless noted 5).A minimum of 10 inch flashing shall be installed between the building and ledger. NAIL NAIL AT PANEL EDGES SUPPORTS IN THE PANEL FIELD otherwise. Ledger to be fastened to building with 1/2"dia. bolts with washers and nuts JOINT DESCRIPTION QTY. SPACING4'EDGE ZONE 8d COMMON @ 6-O.C. 8d COMMON @ 12-O.C. SEE NOTES: 1,3(BOTH FIELDS) 4). Unless otherwise noted, all bearing wall headers to be(2)2x10#2+STIR. Doug. Fir. where needed. GYPSUM 5d COOLERS 7" O.C.EDGE NOTE: 2 FOR PANEL FIELID Bearing wall headers to have(2)jack studs and(2)full length studs on each side of all 6). Concrete piers shall be a minimum 6"above grade. WALLBOARD 10"O.0. FIELD i INTERIOR ZONE 18d COMMON @ 6"O.C. 8d COMMON @ 12"O.C. SEE NOTE:3 openings. LVL headers to have(3)jack studs and(2)full length studs on each side of WALL SHEATHING: openings. Bearing wall window sills shall also have(2)window sill plates for 2x4 wall 7).All joists to be supported with hangers and anchors. Each Joist shall also be anchored NOTES openings between 41 and 6'0 and 2x6 wall openings between 511 and 8'9.Provide fire to girder(s). JOINT DESCRIPTION NAIL NAIL THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY. and blocking where applicable, QTY. SPACING 5).All Push beams/headers to be installed with heavy duty galvinized hangers and 8),Covered Roofs shall be assembled and anchored the same manner as a typical building. STRUCTURAL 8d COMMON AS PER TABLE 3.9 1). For wall sheathing within 4 feet of the comers,the 4 foot edge zone attachment requirements shall PANELS WFCM-SBC be used. anchors where applicable to all connecting joists. PLUMBING NOTES 7116"OSB 6d COMMON 34'O.C.EDGE 6). Double up floor joists under walls that run parallel to the floorjoist and under bathtubs, 1).All water supply,drainage and venting to be installed as per N.Y.S. Residential PLYWOOD 6"O.C. FIELD 2).Tabulated 12 inch o.c.nail spacing assumes sheathing attached to stud framing members With Floors to have ceramic the installed shall be verified for proper load capacity unless noted Construction Code. GYPSUM 5d COOLERS 7" O.C. EDGE G>0.49. For framing members with 0.42<G<,the nail spacings shall be reduced to 6 inches o.c. on plans. I WALLBOARD I 1 10'O.C . FIELD 3).For exterior panel siding,galvinized box nails shall be permitted to be substituted for common nails. 7). Provide 2- 1-314"thick microlams(height to match floor joists)around stairwell and/or 2).Verify septic system with the Engineer for Suffolk County Health Department approval. FLOOR SHEATHING: other access openings unless otherwise noted(typical). 3), If wall studs, plates or joists are cut out during installation for any plumbing related work, NAIL NAIL NOTE: 8). Dormers running up roof rafters are to be supported by double rafters on either side provide adequate bracing and plates to protect and secure the structure.Verify with the JOINT DESCRIPTION QTY. SPACING CONTRACTOR TO PROVIDE SOIL TEST TO VERIFY where applicable unless otherwise noted. state code and manufacture's recommendation for maximum hole size and spacing permitted. STRUCTURAL PANELS 8d COMMON 6"O.C. EDGE EXISTING CONDITIONS. MINIMUM 3000# CAPACITY. 9). Provide blocking1bridging in floor joists at 8'0 o.c..Use solid blocking in floor joists HVAC SYSTEM NOTES 1"OR LESS 12"O.C. FIELD 1). PROVIDE 5/8'TYPE-X SHEETROCK FIRE STOPPING AT 10'0 MAXIMUM DISTANCES FOR NON ACCESSIBLE AREAS, under all bearing walls. 1), Mechanical subcontractor is responsible for adhearing to all applicable codes and safety NOTES: 2). USE SIMPSON HANGERS AND ANCHORS WITH Z-MAX TRIPPLE PROTECTIVE COATING FOR CONTACT WITH ACQ. requirements 10). Provide insulation baffles at save vents between rafters. Install draft blocking as . 3). INSTALL 1 -Co2 DETECTOR IN ADDITION TO SMOKE ALARMS PER FLOOR. THESE NOTES ARE ONLY TO BE REFERRED TO IF needed. 2). HVAC subcontractor is to fully coordinate all system data and requirements With the MENTIONED IN SCHEDULE NOTES ONLY. Section R602.8 - FIREBLOCKING REQUIRED equipment supplier. Fireblocking shall be provided to cut off all concealed draft openings (both vertical and horizontal) 11). Unless otherwise noted,all roofs and walls to have a minimum 1/2"thick,4-ply Fir 1). Nailing requirements are based on wall sheathing and to form an effective fire barrier between stories, and between a top story and the roof space. CDX exterior sheathing grade plywood. Plywood to cover over plates and headers. 3). HVAC subcontractor to provide final system layout drawing and submit it to the General nailed 6"on-center at the panel edge.If wall sheathing Fireblocking shall be provided in wood-frame construction in the following locations. Contractor and owner for final review and approval, is nailed 3"on-center at the panel edge to obtain higher 12). Unless otherwise noted use 314"thick T&G PTS Fir or Advantech plywood subficior shear capacities,nailing requirements for structural 1). In concealed spaces of stud walls and partitions, Including furred spaces, at the ceiling and floor adhered with PL400 adhesive and screwed to floor joists.Finished floor to be installed ELECTRICAL NOTES: members shall be doubled,or alternate connectors, over subfloor as per manufacture's instructions. such as shear plates,shall be used to maintain load path. levels. Concealed horizontal furred spaces shall also be fireblocked at intervals not exceeding 10 1).All electrical to be installed as per N.Y.S.Residential Construction Code. feet. Botts or blankets of mineral or glass fiber shall be allowed as fireblocking In walls constructed 13).All bathroom walls to have 1/2"thick moisture-resistant sheetrock.Garage walls and 2).When wall sheathing is continuous over connected using parallel rows of studs or staggered studs. ceilings and over furnace to have 518"thick type-x sheetrock.All other parts of building 2).All electrical work shall be approved by a qualified Underwriter. members,the tabulated number of nails shall be permitted to have regular 1/2"sheetrock.All walls to be taped and finished. 3). Install Smoke detectors and Carbon Monoxide detectors throughout as per section R317 to be reduced tot -16d nail per foot. 2). At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, 14).All roof with a pitch less than 4:12 shall be installed with an Ice&Water barrier or of N.Y.S. Residential Construction Code. drop ceilings and cove ceilings. approved equal. Flat roofs shall be applied with a Fiberglas base sheet with an EPDM torch down type material over. 3). In concealed spaces between stair stringers at the top and bottom of the run. Enclosed spaces under stairs shall comply with Section R314.8, N.Y.S. Residential Code, 16).All sill plates and wood in contact with concrete to be pressure treated. Sill plates to be installed with a foam sill gasket andcap-r--lex termite shield or approved equal. 4). At openings around vents, pipes and ducts at ceiling and floor level, to resist the free passage of flame and products of combustion. �( 5). For the fireblocking of chimneys and fireplaces, refer to Section R1001.16. N.Y.S. Residential Code. 2. 02A\ N Kevin Perry Architect kevinperry@att.net Alterations to 400 King Street, Orient NY 212.727.9907 Structural notes SNO1 October 5, 2016 WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS USE THE FOLLOWING APPROVED USP METAL CONNECTORS FOR PROPER WIND RESISTANT & GOOD CONSTRUCTION. FOLLOW MANUFACTURE'S RECOMMENDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY. KING STUDS & ENDWALL RAFTER WALL STUD CRIPPLE STUD BOTTOM PLATE RIDGE - .1 m . . LEDGER BATHTUB HEADER E) DOUBLE JOIST SIDEWALL RAFTER JACK STUDS FLOOR USP NUMBER DESCRIPTION APPLICATION IST, ADS5 HOLD DOWN CONNECT TO 1 SIDE OF ALL CORNERS ANCHOR TO FOUNDATION W/ANCHOR BOLTS CONNECT TO 1 SIDE OF ALL CORNERS ON LOCATION USP NUMBER DESCRIPTION APPLICATION I LOCATION USP NUMBER DESCRIPTION APPLICATION RAFTER SIZE USP NUMBER DESCRIPTION A BATH I SPA TUBS TO HAVE A DOUBLE FLOOR JOISTS UNDER FOR ADDED SUPPORT 15 HOLD DOWN BOTH BOT.PLATE OF 2ND FLOOR AND TOP APPLICATION SUPPORT EACH WALL RUNNING PARALLEL WITH THE FLOOR 2ND. ADS ANCHOR PLATES OF 1ST.FLOOR,CONNECT THROUGH ALL OPENINGS LSTA12 11-114"x1720ga.STRAP APPLY TO EACH JACK STUD ROOF I LSTA24 j1-114'x24'2Gga.STRAP iAPPLY OVER RIDGE TO EACH RAFTER 2x6-2x8 LS26 18ga.SLOPE HANGER APPLY TO EACH RAFTER I LEDGER JOIST DIRECTION WITH(2)JOISTS.UNDER WALL ITHE FLOORS TO EACH OTHER W1 THREADED ROD. ALL OPENINGS RT3ORRT7 TYDOWN ANCHOR APPLY TO EACH CRIPPLE STUD 2XI0 LS21 0 18ga.SLOPE HANGER APPLY TO EACH RAFTER i LEDGER FOR JOIST NOT DIRECTLY UNDER PARALLEL WAILLS,PROVIDE BLOCKING @24-OC Iff OR I WALL STUD THROUGH-ROOF EXHAUST VENTS SELECTED AND LOCATED BY CONTRACTOR METAL STRAP ----- CRICKET AT TOP-SIDE OF VENTILATION CHANNEL RIM BOARD CHIMNEY RAFTER AS REQUIRED 1 SILL PLATE(S) WALL SHEATHING RAFTERS L L 1 . MAINTAIN L( VENTILATION WOOD JOIST SIDEWALL FLASHING FOUNDATIONTOP PLATE BLOCKING • FINISH WALL AND MOISTURE > MA 2x4 LEDGER BLOCKING STAPPING TO BE ATTACHED TO WALL STUDS @48"OC BARRIER TO LAP FLASHING I 2x4 SOFFIT JOIST AND ALL WINDOW/DOOR OPENING JACK STUDS AT WALL--MAINTAIN GAP ATTIC SHALL BE PROVIDED WITH A FASCIA FLOOR JOIST DEPTH USP NUMBER DESCRIPTION APPLICATION BETWEEN WALL FINISH AND N MINIMUM NET FREE VENTILATING AREA GUTTER ROOFING TO AVOID SOAKING WALL STUD NOT LESS THAN 1/150 OF THE AREA OF WOOD GIRDER INSTALL4'0"O.C. THE SPACE VENTILATED. ALL OPENINGS 4'.8* LSTA24 1-114"x24"20gs.STRAP AND JACK STUDS �z SHALL BE COVERED WITH CORROSION- ONTIN SCREENED VENT ON ALL OPENINGS PROVIDE HEMMED EDGE AT RESISTANT METAL MESH WITH MESH CONTI N.SOFFIT/EXT.PLYWOOD INSTALL 4'0"O.C. FLASHING TO FORM CHANNEL LOCATION USP NUMBER DESCRIPTION APPLICATION OPENINGS OF 1/4 INCH IN DIMENSION, 8"-14" LSTA30 1-114"x30"18ga,STRAP AND JACK STUDS AND SO AS TO MAINTAIN AIR SOFFI TED EAVE CONNECT TO ON ALL OPENINGS GAP TO PREVENT CAPILLARY 4"-6*'RAFTER RT10 10-3/4'x 18ga.TYDOWN ANCHOR EACH RAFTER INSTALL4'0"O.C. ACTION PROVIDE BLOCKING BETWEEN JOISTS THAT ARE SPICED AND 14*-16" LSTA36 1-1/4"46"18ga.STRAP ANDJACKSTUDS 8*-12"RAFTER RT20 21-1/8"x 20ga.TYDOWN ANCHOR CONNECT TO ROOF VENTILATION OVER BEARING WALLS AND HEADERS ON ALL OPENINGS KEEP ROOFING NAILS OUT EACH RAFTER SOFFI TED EAVE DETAIL 2ND.FLOOR WALL OF FLASHING ROOFING LAPS BASE FLASHING 4 INCHES BASE FLASHING WRAPS CORNERS, RAFTER RIDGE CAP OF SAME EXTENDS UNDER SHINGLES AT MATERIAL AS ROOFING SIDES 4 INCHES AND LAPS NAILED TO SHEATHING SHINGLES AT BASE MIN.4 INCHES THROUGH VENT DJOIST SIDEWALL FLASHING TOP PLATE GIRDERIHEADER 1ST.FLOOR WALL STAPPING TO BE ATTACHED TO WALL STUDS @48-OC WOOD JOIST AND ALL WINDOW/DOOR OPENING JACK STUDS METAL FLASHING AT ALL EAVES, SIDEWALLS, WALL STUD FLOOR JOIST DEPTH JUSP NUMBER DESCRIPTION APPLICATION AND RAKES -- PROVIDE HEMMED EDGES SO RAFTER INSTALL 4'0"O.C. AS TO FORM DRAINAGE CHANNELS AND 4"-8" LSTA36 1-1/4"x36"18ga.STRAP AND JACK STUDS PREVENT CAPILLARY ACTION LOCATION - USP NUMBER DESCRIPTION APPLICATION PRE-MANUFACTURED ON ALL OPENINGS CONNECT EACH RIDGE VENT FOLDS KEEP SHEATHING MIN. 1-112* ALL JOISTS CONNECTED TO A FLUSH HEADER TO BE SUPPORTED WITH INSTALL 4'0"O.C. RAFTERPLATE RT15 TYDOWN ANCHOR RAFTER TO PLATE OVER RIDGE TO FROM PEAK TO ALLOW FREE THE PROPER STEEL CONNECTOR. 8'-16« MSTA48 1-1/4"x48"I 6ga.STRAP AND JACK STUDS CONNECTCONFORM TO SLOPE AIR PASSAGE IF ABLE,SET FIR JOISTS APROX.11r HIGHER THAN LVL HEADERS ON ALL OPENINGS PLATE/WALL SPTH4 STUD PLATE ANCHOR OVER PLATES TO EACH STUD OF ROOF TO ALLOW FOR SHRINKAGE,&REDUCE BUMP OUTS DBL.SILL PLATE TERMITE SHIELD SUBFLOOR SILL GASKET WOOD JOISTS <, A CONC.SLAB GASKET 2x6 /2x8 CONTINUOUS WOOD PLATE NEOPRENE TYP.CONC.FOUNDATION DAMPPROOF EXTERIOR 6 MIL.POLY V EMIL POLY ON EXTERIOR GRANULAR FILL BOLTED TO STEEL BEAM WITH VSTEEL COLUMN 1/2 " DIA. BOLTS 0 48" ox. STAG A > 4 4 ROOF JACK CONC.SLAB STEEL BEAM $A COMPACT FILL ex1le x8* STEEL ROOFING LAPS TOP AND BOTTOM PLATE KEYWAY FOOTING a V 4 FLASHING AT WITH 1/2" x 6" ANCHOR BOLT CONIC,FTG. A-4 ANCHOR BOLT CONNECTION USE WITH 30 SQUARE WASHERS SIDES AND TOP 1/2- OUT (USP LBPS58 OR BP583) REINFORCING BAR FOUNDATION 518"DIA.ANCHOR BOLT 3' STEEL COLUMN DRAIN TILE V ANCHOR BOLT CONNECTION SUPPORTING MAXIMUM SPACING FLASHING LAPS 10 KIPS SILL PLATE TO FOUNDATIONI STORY 72"QC ROOFING AT BOTTOM (CRAWL SPACE OR FOUNDATION) TYPICAL CONC,FOUNDATION.APPLY PILASTERS SILL PLATE TO FUNDATIN TYPICAL BEAM DETAIL WHERE NEEDED FOR STRUCTURAL BRACING, MIN.3"STEEL COLUMN ANCHORED TO 24"x24"x12"CONC.FTG. (CRAWL SPACE OR OFOUNDATIONO2 STORIES 36"OC) I STEEL BOTTOM BEARING WALL BOTTOM PLATE TO FOUNDATION 1-2 STORIES 5T OC JSLAB-ON-GRADE) ROOF JACKS & VENTS DETAIL CONC.SLAB DOOR FRAME SUIBFLOOR 6X610110 WWM COMPACT FILL GE JOIST USE 2X8 4" SLAB SCOPE FOR BLOCKOUT F STIEEL BEAM P.T.PLATE wMM RIVEWAY NOTCH JOIST AND ADJUST HEIGHT 000 I12"AIR S CE (WITH A NAILING PLATE IF NEEDED) ATEND AND • TO BE APROX.1/2"OR HIGHER THAN e. '4 ADES OF WOOD 4 GRADE 4 A STEEL BEAM TO ALLOW FOR SHRINKAGE —1 0 4 BEAMS *4 4 6X6 W.W.M. A 4 4 0, (PROVIDE STRAPPING TO KEEP JOISTS ALIGNEID) 12" 4 4 4 A-4 'A NOTCH BEAM FOR MUDSILL IF REQUIRED–MAXIMUM ` 4 A .0 SUIDIFLOOR MIN 4 REINFORCING BAR NOTCH EQUALS 114 DEPTH OF BEAM a DRAIN TILE IAF 12' SHEET METAL/30#FELT UNDER BEAM AT POINT OF CONTACT WITH CONCRETE OR CONC,BLOCK STEEL SEAM " TYPICAL CONC.MONOLITHIC FOUNDATION.REINFORCE WITH(2)#4 REINFORCING BARS THICKEN SLABS BENEATH BEARING WALLS AND COLUMNS, 4 SHIMS TO LEVEL BEAM PLATE(BOLTED TO BEAM) REINFORCE FOOTING WITH(2)#4 REINFORCING BARS. 3*MINIMUM BEARING SURFACE FOR WOOD BEAM GARAGE DOOR BLOCKOUT BEAM POCKET 2. CO, 0 021 A3 A OF IN Kevin Perry Architect Alterations to 40 0 King Street, Orient NY kcvinperry@att.net 212.727.9907 Structural notes October 5, 2016 411 ri 0 io :14" Ih ►10 STAINLESS STEEL OR GALVANIZED W0.5NEn5� r( kJ 1/2'APR RATED SHEATHINGGRADE PLYWOOD � I (aL7ERNnT1Y[VE:7116°0.5.8.) *1'•�� � � ' I O �E �T, Lcm.Mwwmrve:me1 #10 STAINLESS STEEL III � (II � OR GALVANIZED I WOOD SCREWS W( WASHERS @ 12"o.c mnoow say q I TYPICAL,WINDOW OPENING (LESS THAN 4'-0X8'-0" OPENING) TYPICAL DOOR OPENING (LESS THAN 4'-0X8'-0" OPENING) 4"OC Ire ZI 314"APA PLYWOOD SHegitimG TI 2X4 DF#2 STUDS #10 STAINLESS STEEL w�oosc�ae�w�sw, f f f WASHERS 012'o.C. MULTIPLE airw000 auEntauEs 2.1X4 DFA2 SPUDS CONNECTED TOGETHER WITH STAINLESS STEEL OR GALVINRED BOLTS W)WASHERS AND NUTS @ 2'-0"O.C. TYPICAL MULTIPLE OPENINGS (MORE THAN 4'-0X8'-0" OPENING) WIND-BORNE DEBRIS PROTECTION FOR WOOD STRUCTURAL PANEL AS PER TABLE 1609.1.4, N.Y.S. RES. CODE: ALTERNATIVE FOR OPENING PROTECTION (IF NOT USING IMPACT GLAZING) WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/16" ' AND MAXIMUM PANEL SPAN OF 8 FEET SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE-AND TWO-STORY BUILDINGS. PANELS SHALL BE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED. (REFER TO SECTION 1609.1.4, 1609.6.5 AND TABLE 16091,4 OF N.Y.S. RESIDENTIAL <-`�P PE�R� CONSTRUCTION CODE). THIS IS NOT A SUBSTITUTION FOR DESIGN-PRESSURE.ALL OPENINGS MUST HAVE DESIGN-PRESSURE UPGRADES WHERE APPLICABLE. ALL PANELS MUST BE CUT TO SIZE AND READY TO USE ON ANY NEW WINDOWS AND DOORS. SHUTTERS MUST BE MARKED FOR WHAT OPENING IT IS TO COVER. HARDWARE MUST ACCOMPANY SHUTTERS FOR INSTALLATION. Kevin Perry Architect kevinperry@Alterations to 400 King Street, Orient NY att.net 212.727.990' Structural notes O October 5, 2016