Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
43574-Z
rr Town of Southold 11/6/2019 P.O.Box 1179 {; 53095 Main Rd 4,� Southold,New York 11971 ,rr..27[uj i1 CERTIFICATE OF OCCUPANCY No: 40836 Date: 11/6/2019 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 625 Dean Dr, Cutchogue SCTM#: 473889 Sec/Block/Lot: 116.-5-7 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/12/2019 pursuant to which Building Permit No. 43574 dated 3/21/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Sullivan,Brian&Adams,Marjorie of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 43574 04-19-2019 PLUMBERS CERTIFICATION DATED i_ Authorized Signature 1- TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE 4 SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 43574 Date: 3/21/2019 Permission is hereby granted to: Sullivan, Brian 253 W 73rd St Apt 8C New York, NY 10023 To: install roof mounted solar panels as applied for. At premises located at: 625 Dean Dr, Cutchogue SCTM # 473889 Sec/Block/Lot# 116.-5-7 Pursuant to application dated 3/12/2019 and approved by the Building Inspector. To expire on 9/19/2020. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00, Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00,Commercial$15.00 Date. AD�� New Construction: Old or Pre-existing Building: (check one) Location of Property: 625 Dean Drive, Cutchogue House No. Street Hamlet Owner or Owners of Property: Brian Sullivan Suffolk County Tax Map No 1000, Section 116 Block 5 Lot 7 Subdivision Filed Map. Lot: Permit No. 5 Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ "50 pplicarglinature pF SOUryQI 0 Town Hall Annex Telephone(631)7654802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 �Q roger.richert(a_town.Southold.ny.us Southold,NY 11971-0959 COU '`` BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To Brian Sullivan Address: 625 Dean Drive city Cutchogue st: New York 11935 Building Permit#- 43574 Section: 116 Block: 5 Lot: 7 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Sunation Solar License No: 33412-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures 11 TVSS Other Equipment: 10.56 KW Roof Mounted Photovoltaic System to include; 30- PowerXT-360 W Panels 1- SE 1000 Inverter, 60A AC Disconnect. Notes: �7 Inspector Signature: Date: April 19, 2019 0-Cert Electrical Compliance Form.xls of SOUlyO6 # # TOWN OF SOUTHOLD BUILDING DEPT. e 765-1802 INSPECTION 4 [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE /g INSPECTOR<�j7� Graham Associates 1981 Union Blvd. Bay Shore,N.Y. 11706 Building Consultants & Expeditors (631)665-9619 Fax(631)969-0115 July 18, 2019 Town of Southold Building Department NOV - 6 2019 Re: Permit# P 1913 52 Sullivan Residence 625 Dean Drive, Cutchogue Installation Inspection Date: 04-06-2019 To Whom It May Concern, The roof mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the approved plans and is certified by Graham Associates to be in compliance with the minimum requirements of the Town, the 2015-International Residential Code and the 2017-New York State Uniform Code Supplement and the Provisions of ASCE 7-10. If you have any further questions, do not hesitate to call. K, Srrt,°i; . Mi c1 e` 1i�n, RA FIELD INSPECTION REPORT .DATE COU=NTS FOUNDATION (1ST) I 'FOUNDATION (2ND) � • :� tr i z 0 ROUGH FRAMING& d~ P'L'UMBING y I -5 c,P INSULATION PER N.Y-. , 3 STATE ENERGY CODE FINAL ADDITIONAL CO NTS a� 41qllq _ 0 z mow 'd m T za Z 0 ca z d H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying° TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502 (�� kk Survey SoutholdTown.North Fork.net PERMIT NO. \ Check Septic Form N.Y.S.D.E.0 Trustees C O Application Flood Permit Examined ,20 Single&Separate Stom1-Water Assessment Form 2( 1 c( Cont Gamton - Approved ,20 SUNation Solar Systems,Inc Disapproved a/c Boulevard,Ronkonkoma NV 11779 D P1-'+11;-PiV .— Phone:(631)750-9454 Xt ta�1 r (ZD--�a ' 2 Nr^R 1 2 ; ;'} Building Inspector APPLICATION FOR BUILDING PERMIT Date 20(0 TO"OF SOUTU INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. (Signature o ap tcan or name,if a corporation) SUNation Solar Systems,Inc 171 Remington Boulevard,Ronkonkoma NV 11779 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder SUNation Solar Systems,Inc-Contractor Name of owner of premises 625 Dean Drive,Cutchogue 11935 (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer Scott Maskin-President (Name and title of corporate officer) Builders License No.44104-H Plumbers License No. NIA Electricians License No.33412-ME Other Trade's License No. 1. Location of land on which proposed work will be done: 625 Dean Drive Cutchogue House Number Street Hamlet County Tax Map No. 1000 Section 1s Block _Lot k / Subdivision Filed Map No. _Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Residence b. Intended use and occupancy Residence with addition of Solar Panels 3. Nature of work(check which applicable):New Building Addition_El Alteration ✓l Repair Removal Demolition Other Work fio 0-r Pares (Description) 4 Estimated Cost $31,620 Fee $200.00 (To be paid on tiling this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor_ If garage,number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any- Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions:Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner I I Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law,ordinance or regulation?YES---NO x 13. Will lot be re-graded?YES_NO X Will excess fill be removed from premises?YES NO X p � 1chuc,�,� 14. Names of Owner of premisea-L- Cc1 111 C�� Address `�{ y���f1rL` i honr e No.Cl't I LP�1 Name of Architect William c Fisher Address PO eoz 30 Oak08k1 NY 11769 Phone No 631-786-4419 Name of Contractor SUNaoonSolar Systems,1- Address 171Ram—nBw—M.Ronka+o,naNYPhone No. 631-750-9454 15 a. is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO X *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.0 PERMITS MAY BE REQUIRED b.Is this property within 300 feet of a tidal wetland?*YES NO X *IF YES,D.E.C.PERMITS MAY BE REQUIRED 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey 18.Are there any covenants and restrictions with respect to this property?*YES NO X *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Scott Maskin-President-SUNation Solar Systems,Inc. being duly swom,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the Contractor (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application, that all statements contained in this application are true to the best of his knowledge and belief,and that the work will be performed in the manner set forth in the application filed therewith. Sw M to before me this day of 20P NotaryPublicSignature of Applicant VICTORIA M. WALKER NOTARY PUBLIC-STATE OF NEW YORK No O1 WA631 9756 Qualified in Suffolk County My Commission Expires February 23a2 �9 /� "' Scott A. Russell tea° /r S]F01 b.MWA\ F1E1K SUPERVISOR ' I �T Z I��l[A\1�A\�G]EI\�lUE1�T SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 Town of Southold 01 CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT INVOLVE ANY OF THE FOLLOWING: (CHECK ALL THAT APPLY) 1 Yes No 09 A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑[� B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑P C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑� D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑ E. Site preparation within the one-hundred-year floodplain as depicted on FIRM Map of any watercourse. 11P F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department witour Building Permit Application. APPLICANT. (Property O aner,Design Professional,Agent,Contractor,Other) S.C.T.M. `: 1000 Date District Q NAME. BClan Van J 1 l� r Sect ton Block Lot FOR BUILDING DEPARTMENT USE ONLY jC ntact information T,1 p I..berr, Reviewed B - - — — — — — — — — — — — — — — Date: '). ?5jj j1q Property Address/ Location of Construction Work: — — — — — — — — —j— — — — — — 625 Dean DSIV@ Approved for processing Building Permit. Stormwater Management Control Plan Not Required. Cutchogue, NY 11935 Stormwater Management Control Plan is Required. ❑ (Forward to Engineering Department for Review.) FORM # SMCP-TOS MAY 2014 Graham Associates 1981 Union Blvd. Bay Shore,N.Y. 11706 Building Consultants & Expeditors (631)665-9619 Fax(631)969-0115 March 6, 2019 Town of Southold Building Department 54375 Rt. 25 Southold, NY 11971 Re: Sullivan Residence 625 Dean Drive Cutchogue, NY 10.65 KW Rooftop Solar Photovoltaic System To Whom It May Concern, Please be advised that I have analyzed the existing roof structure at the above-mentioned premises and have determined that it is adequate to support the additional load of the solar panels and a 130 mph wind load without overstress, in accordance with the following: 2015 International Residential Code (2015 IRC, 2ND PRINTING) + 2017 New York State Uniform Code Supplement (2017 NYSUCS); Town of Southold Local Code, Long Island Unified Solar Permit Initiative, (LIUSPI); and 2014 National Electric Code NFPA 70/2014 National Electric Code including ASCE?-10 rther questions, do not hesitate to call. �V in � F OF N�� pF SO�IyQI 0 Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1 179 G • 0 Southold,NY 11971-0959 'Q BUILDING DEPARTMENT May 9, 2019 TOWN OF SOUTHOLD SunNation Solar 171 Remington Blvd Ronkonkoma NY 11779 Re: Sullivan, 625 Dean Dr, Cutchogue TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: NOTE: Engineer's certification letter stating the panels were installed to the roof per NYS Building code required Electrical Underwriters Certificate A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT —43574— Solar Panels SO�ryo �o Town Hall Arm" 4 Telephone(631)765-1802 54375 Main Road cn r ���O � oP.O.Box 1179 rocer.richeamsoutl nY us Southold,NY 11971-0959 �� Wa DING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY. V�� Date: g Company Name: SUNation Solar Systems, Inc. Name: Scott Maskin License No.: 33412-ME Address: 171 Remington Blvd, Ronkonkoma, NY 11779 Phone No.: 631-750-9454 JOBSITE INFORMATION: (*Indicates required information) *Name: *Address: �, A ov)muo Q *Cross Street: *Phone No.: Permit No.: Tax Map District: 1000 Section: �1�D Block: Lot: _ *BRIEF DESCRIPTION OF WORK(Please Print Clearly) �1 (Please Circle All That Apply) *Is job ready for inspection: YES Rough In Final *Do-you need a Temp Certificate: YES/ Temp Information(if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for rnspectton Form sOf soar �1 Town Hall Annex 41 4 Iii Telephone tbTd l) 6022019 54375 Main Road {b31)7 gg5Qg P.O.Box 1179 Q roger.rlcheddrofi sOAM&ny.us Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Kaitlyn Sheehan Date: 04/08/199 Company Name: SUNation Solar Systems, Inc. Name: Scott Maskin License No.: 33412-ME, 40325-ME 1 ! Address: 171 Remington Blvd, Ronkonkoma, NY 11779 Phone No.. 631-750-9454 JOBSITE INFORMATION: (*Indicates required information) *Name: Brian and Marjorie Sullivan *Address: 9 Dean rive Cutchogue NY *Cross Street: New Suffolk Avenue ^ *Phone No.: 917-696-1649 Permit No.: 43574 Tax Map District: 1000 Section: 116 Block: 5 Lot: 7 *BRIEF DESCRIPTION OF WORK(Please Print Clearly) UMOOW Roof Mounted Solar Photovoltaic Systems including:30 x Solaria POWERXT-360 PV Modules.. 1- Solaredge SE1000OH-US Inverterw/disconnect 1-60amp Single Phase Fused A/C Main Service switch (Please Circle All That Apply) *Is job ready for inspection: YE / NO Rough In Final *Do-you need a Temp Certificate: EO/ NO Temp Information(If needed) *Service Size: 1 Phas 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Undergroundumber of Mete Change of Service overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form 1 SUFFOLK COUNTY DEPT OF LABOR, LICENSING 8 CONSUMER AFFAIRS MASTER ELECTRICIAN Moe SCOTIA MASKIN This certifies=hat bearer is duly SUNATION SOLAR SYSTEMS INC licensed by the County of Suffolk `�"" " O. ft—d 7��� 33412-ME 06/24/2003 Com.b— EUMAn ,a� ofi/otnot s New York State Insurance Fund Workers'Compensation&Disability Benefits Specialists Since 1914 199 CHURCH STREET,NEW YORK,N.Y.10007-1100 CERTIFICATE OF WORKERS' COMPENSATION INSURANCE 0 R E = A A A A A A 753118816 SUNATION ROOFING SERVICES INC 171 REMINGTON BOULEVARD 0 RONKONKOMA NY 11779 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z2160 670-2 482687 01/01/2019 TO 01/01/2020 3/12/2019 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO. 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY. IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COM/CERT/CERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY NEW YORK STATE INSURANCE FUND "J DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER.453899859 U-26.3 A��® DATE(MM/DD(YYYY) CERTIFICATE OF LIABILITY INSURANCE 02/12/2019 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER CONTACT Joseph Price NAME: Joseph P Price Jr Insurance Brokerage Inc. PHONN Ext 631-509-4509 FMC No Priceagy.com E-MAIL Jose h Pricea ADDRESS: p gy'Com P O BOX 171 INSURER(S)AFFORDING COVERAGE NAIC# Mt.Sinai, New York 11766 INSURER A. Southwest Marine&General Insurance Company 12294 INSURED INSURER a. New York Marine&General Insurance Comany 16608 SUNation Solar Systems Inc. INSURER C. Southwest Marine&General Insurance Company 12294 171 Remington Blvd. INSURER D. Ronkonkoma,NY 11779 INSURER E. INSURER F. COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ITR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER MM/DD/YYYY MY EFF OMIUDD/YYYY LIMITS X COMMERCIALGENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE F%/1 DAMAGE TO NTED OCCUR PREMISES EaEoccurrence) $ 100,000 MED EXP(Any one person) $ 5,000 A X PK201900009827 02/11/2019 02/11/2020 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE $ 2,000,000 X POLICY PRO- ❑LOC PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 Ea accident ANY AUTO BODILY INJURY(Per person) $ B ALL OWNED SCHEDULED AU201900009974 02/11/2019 02/11/2020 BODILY INJURY(Per accident) $ AUTOS X AUTOS X HIRED AUTOS X NON-OWNED PROPERTY DAMAGE $ AUTOS Per accident d $ UMBRELLA LAB X OCCUR EACH OCCURRENCE $ 3,000,000 C X EXCESSSLLIAB CLAIMS-MADE UM201900003418 02/11/2019 02/11/2020 AGGREGATE $ 3,000,000 X DED RETENTION$ 10,000 $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE E L.EACH ACCIDENT $ OFFICERIMEMBER EXCLUDED? F7N/A (Mandatory In NH) E L DISEASE-EA EMPLOYE $ If Yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT 1$ A Installation Floater PK201900009827 02/11/2019 02/11/2020 Occurrence $25,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,maybe attached it more space is required) The Town of Southold is included as additional insured for licensing purposes,as required by written contract and subject to terms of the policy Additional insured forms and/or other policy forms are available upon request. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town of Southold ACCORDANCE WITH THE POLICY PROVISIONS. 54375 Main Road AUTHORIZED REPRESENTATIVE Southold,NY 11971 Joseph Price �` 1 ®1988-2014 ACOTMORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD ALL OWN-71 :?,L 'Y vyTE &TCODES p 437 C(-)MPL maw ly()RK REO AS SOUP -ED ION 4. CQ BE: col PL ALL (-,0NST'r—'- Of-by YORK STATF: F FOR ERRORS. DESIGN 01 UTILITY METER - ® 'GISTERF PLAN KEY SERVICE DISCONNECT - 10, O 4%CHA@j PV-I SITE PLAN MAIN SERVICE PANEL-VENT PIPE - A-I PARTIAL LAYOUT INVERTER- A-2 ROOF ACCESS PLAN PANEL PHOTOVOLTAIC- ® -I z to E-I ELECTRICAL ONE UNE DIAGRAM D DISCONNECT- ® � � y SUPPLY SIDE CONNECTION -® L-I LABELING SCHEMATIC SENSE MONITOR-® 17 G-1 PHOTOS EV CHARGER- Y EXTERIOR LOCATION- 1 (exr) T =: IST FLOOR LOCATION- uer) BASEMENT LOCATION-cel GARAGE LOCATION-« SUNation sole",.n.ewia be SUNATION SOLAR SYSTEMS .ys III REMINGTON BLVD. ROOF STRUCTURE RONKONKOMA NY 11719 N RAFTER / SPACING-2" X 6"' / I6"' OG. „L,a„"„��„4A,p„_�._ INSTALLER 435rp ACTUAL SPAN-12'-5" r NUMBER 110, 10. 10. 111101 111111. 110.w CUSTOMER INFO SHEATHING-PLYWOOD SULLIVANVVVVVVVVRESIDENCE COLLAR TIES-N/ARIDGE (30)PV MODULES 625 DEAN DRIVE 15-11.5" TYPE / LAYERS-ARCH. ASPHALT /I vvvvvvv vv GUTCHOGUE 11935 PHOTOVOLTAIC JOSNUMBER MODULE 1 X71 22 DATE 3.6.1AVXM 9 JOB HARDWARE / QTY. JOB NOTES OPTIMIZER KITS-30 L-FEET'68 RAIL I. PLEASE USE 48'SPACING ON ROSURE AFTER 168 RAIL 20 LUGS-3 2"X 6"l I6"O G. ESRC9 DUE TO WIND RAIL SPLICES-16 8"X100'SCREEN-3 MID CLAMPS-54 U-ANCHORS-N/A SOFFIT END CLAMPS-12 PITCH POCKETS-N/A ACTUAL SPAN FULL HOUSE ROOF PLAN EXTERIOR WALL SCALE- N.T.S. ROOF SECTION(TYP.) SCALE- N.T.S. FASTENER REQUIREMENTS- BUILDING REVIEW NOTE NOTES TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE I. AN 18" WIDE CLEARING(FREE OF SOLAR TOTAL ARRAY AREA=595 SF ENCLOSED DOCUMENT FOR MINIMUM ACCEPTABLE EQUIPMENT)SHALL BE PROVIDED ALONG AT WIND LOAD- ASCE 10(SEE CALCULATIONS, THIS SHEET)41.5 PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS LEAST ONE SIDE OF THE ROOF RIDGE ON THE PSF MAX SPECIFIED IN THE BUILDING AND/OR RESIDENTIAL SAME SIDE AS THE SOLAR EQUIPMENT OR ON MODEL SOLARIA POWERXT-355R-P0 TOTAL UPLIFT=41.5 PSF X 595 SF=24692.5 LBS CODE OF THE STATE OF NEW YORK. THIS REVIEW ANOTHER SIDE OF THE RIDGE THAT DOES NOT ADDITIONAL MATERIALS 355 WATT EA. FASTENER- DOES NOT GUARANTEE COMPLIANCE WITH THAT CODE. HAVE SOLAR EQUIPMENT ON IT IN ADDITION, AN 1. WA 63.8"L X 43.9"W X I.SI"D, 19.45 FTI THAT RESPONSIBILITY IS GUARANTEED UNDER THE 18" WIDE PATHWAY(FREE OF SOLAR EQUIPMENT) 4&#/MODULE(2.4#/sr-)11/2018 LAG SCREW SPEC 203.2, 8/04- (FLAT WASHERS REQUIRED 70 BE USED WITH LAG SEAL AND SIGNATURE OF THE NEW YORK STATE SHALL BE PROVIDED FROM AT LEAST ONE EAVE LICENSED DESIGN PROFESSIONAL OF RECORD THAT OR GUTTER CONNECTING TO THAT 18" ROOF MODULE (30)POWERXT-355R-PD BOLTS) SEAL AND SIGNATURE HAS BEEN INTERPRETED AS AN OPTIMIZER (30)P-310 LAG BOLT WITHDRAWAL VALUE;5/16"DIA., 266 LB/IN X 2-INCH THREAD DEPTH= ATTESTATION THAT, TO THE BEST OF THE LICENSEE'S RIDGE CLEARING. INVERTER x1 (1)SE10000H-US 2. ROOF SHALL HAVE NO MORE THAN A SINGLE 532IMU GAP EACH BELIEF AND INFORMATION THE WORK IN DOCUMENT IS: LAYER OF ROOF COVERING IN ADDITION TO THE STRINGING INV sl a I(z x 15) MINIMUM NUMBER OF LAG BOLTS REQUIRED=24692.5 LBS/532 LBS/LAG BOLT=41 . ACCURATE INVERTER M2 N/A SOLAR EQUIPMENT DRAWN BY STRINGING INV K2 N/A TOTAL RAIL FEET=280'-0"RAIL FT/41 BOLTS=5'-11" • CONFORMS WITH GOVERNING CODES APPLICABLE 3. INSTALLATION OF SOLAR EQUIPMENT SHALL BE RACKING SNAP'N'RACK-ULTRA RAIL MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS"X" USE 4'-0" MAX AT THE TIME OF THE SUBMISSION FLUSH-MOUNTED, PARALLEL TO AND NO MORE JAYSON MORALES PACKAGE STANDARD • CONFORMS WITH REASONABLE STANDARDS OF THAN 6-INCHES ABOVE THE SURFACE OF THE REVISION SYSTEM RATING(OC) 10.65 KW PRACTICE AND WITH VIEW TO THE SAFEGUARDING ROOF DATE DE84GNER NOTE EST.PRODUCTION(AC) 12,148 KWH/YR OF LIFE, HEALTH, PROPERTY AND PUBLIC 4. WEIGHT OF THE INSTALLED SYSTEM SHALL NOT 9T.PRODUCTION SOURCE 9UNATION PRODUCTION CALCULATOR WELFARE IS THE RESPONS151UTY OF THE UCENSEE EXCEED MORE THAN 5-PSF FOR 3.6.19 MANGIN FINAL SPECIAL ATTACHMENTS N/A PHOTOVOLTAICS AND NO MORE THAN 6-PSF FOR >OcXXXX NIA WA STRUCTURAL STATEMENT RESIDENTIAL SOLAR HOT WATER SYSTEMS. WA N/A 5. ANY PLUMBING VENTS ARE NOT TO BE CUT OR >010000< CLIMATIC I GEOGRAPHIC DESIGN CRITERIA - TABLE 8301.20) THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT COVERED FOR SOLAR EQUIPMENT INSTALLATION. XxxX WA WA THE NEW LOADS IMPOSED BY THE PHOTOVOLTAIC ANY RELOCATION OR MODIFICATION OF THE VENT WIND DESIGN SUBJECT TO DAMAGE MODULE SYSTEM INCLUDING UPLIFT f SHEAR. THE REQUIRES A PLUMBING PERMIT AND INSPECTION. SCALE' EXISTING RAFTER SIZES I DIMENSIONS CONFORM TO N.T.S. WIND WIND ICE SPECIAL SEISMIC CLIMATE T11- rU- WINTER AIR MEANIRC-2015 TABLE 8802.5(1)-RAFTER SPANS GROUND SPEED TOPOGRAPHIC WIND EXPOSURE BORNE DESIGN WEATHETERMITE DESIGN BARRIER FLOOD FREEZING ANNUALTITLE'917E PLAN SNOW LOAD (MPH.) EFFECTS REGION CATEGORY DEBRIS CATEGORY ZONE TEMP UNDERLAYMENT HAZARD INDEX TEMP THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE ZONE REQUIRED MOUNTING BRACKETS AND HARDWARE MEET OR MINIMUM DESIGN STANDARDS FOR BUILDING AND MOD SEE EXCEED NEW YORK STATE CODE REQUIREMENTS FOR OTHER STRUCTURES OF THE ASCE 1-10, IRC 2015 20 PSF 130 B YES C 2 C 4A SEVERE 3"-0` TO 15 DEG NA PLANS599 51 THE DESIGN CRITERIA OF THE TOWN. AND NEW YORK STATE UCS 2011. HEAVY EXAMBNER Pvm I .%STE& O%CHA '9 O ?r ! z M .•1 0 17 W YO�� SUNa tion t SOUTH EAST ROOF o., o 12SO TRUE; 23° TILT; 5.25/12 PITCH suNSOLAR SYSTEMS 11H 1 RE MNGTON BLVD 9 30 MODULES RIDGE RONKONKOMA NY 1111 66'-10" NYSERDA INSSTALLETALLE R NUMBER 43 Al ® A A5 A6 CUSTOMER INFO SUWVAN RESIDENCE ss•z a• �r cui 625 DEAN DRIVE CUTCHOGUE I I WE, JOB NUMBER 19122 PHOTOVOLTAIC DATE MODULE(TYP.) 3.6.19 JOB NOTES f SPACING I NIA vv IV IV IT IT V >BETWEEN ROWS SNAP'N'RACK SYSTEM (TYPICAL RAIL All EACH ROW OF ARRAY) (ONLY TWO SHOWN FOR ROOF AREA A1e CLARITY) 2 GUTTER PARTIAL HOUSE ROOF PLAN SCALE: 3116 = 10" DRAWN BY JAYSON MORALES REVISION DATE DESIGNER NOTE 12.12.18 CB MOD.CT 1.11.19 RB MOD.CT 1.25.19 AP MOD CT 3.6.19 MANGIN RNAL Sc- 7=71 CALE' 3/16 = 1 TITLE'PARTIAL LAYOUT LL A- 1 co SUNation sura,e.n.n-ld be e SUNATION SOLAR SYSTEMS 111 REMINGTON BLVD. RONKONKOMA KY 11119 INSTALLER Y NUMBER x' wow Ac4m CUSTOMER INFO SUWvAN RESIDENCE GUT D DRIVEEAN OGUE 11535 y ALTEMIATIVE VBITLATON li'- JOB NUMBER 19122 100 1010. 1010. loop. DATE 0vvvvvvvvv3.6.19 < NOTES (30)PV MODULES 1. N/A Y t 9� vvvvvvvvvv PON ACCESS ROOF A ROOF SURFACE WHICH PROVIDES ACCESS TO THE RIDGE OR PEAK OF AN ADJOINING ROOF SURFACE CONTAINING SOLAR PANELS,MODULES OR ARRAYS AND I& 1. RELATIVELY FREE OF VENTS,SKYLIGHTS AND OTHER OBSTRUCTIONS AMC) 2. DOES NOT CONTAIN SOLAR PANELS,MODULES OR ARRAYS,OR IS A SINGLE RIDGE ROOF WHERE THE TOTAL EDGE WIDTH OF THE SOLAR PANELS,MODULES OR ARRAYS DOES NOT EXCEED 33 PERCENT OF THE RIDGE LENGTH R324.1 ACCESS AND PATHWAYS-ROOF ACCESS,PATHWAYS AND SPAGNG REQUIREMENTS FOR SOLAR PHOTOVOLTAIC SYSTEMS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R324.1.1 THROUGH R324.1.6 DRAWN BY EXCEPTIONS) KEVIN MANGIN I. ROOF ACCESS,PATHWAYS AND SPACING REQUIREMENTS NEED NOT BE PROVIDED WHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED,OR WHERE VERTICAL VENTILATION TECHNIQUES WILL NOT BE EMPLOYED REVISION 2. DETACHED NON-HABITABLE GROUP U STRUCTURES. DATE DESIGNER NOTE R324.1.4 SINGLE RIDGE ROOFS-PANELS,MODULES OR ARRAYS INSTALLED ON ROOFS WITH A SINGLE RIDGE SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO 36 X>00 NIA WA INCH WIDE(514MM)ACCESS PATHWAYS EXTENDING FROM THE ROOF ACCESS POINT TO THE RIDGE. ACCESS PATHWAYS ON OPPOSING ROOF SLOPES SHALL NOT BE LOCATED ALONG THE SAME PLANE AS THE TRUSS,RAFTER OR OTHER SUCH FRAMING SYSTEM THAT SUPPORTS THE PATHWAY >01INXXX WA WA EXCEPTION(S) >000 WA NIA 1. ROOFS WITH SLOPES OF 2 UNITS VERTICAL AND 12 UNITS HORIZONTAL(16.6 PERCENT)AND LESS. 2. STRUCTURES WHERE AN ACCESS ROOF FRONTS A STREET,DRIVEWAY OR OTHER AREA READILY ACCESIBLE TO EMERGENCY RESPONDERS. >000cXX WA NIA 3. ONE ACCESS PATHWAY SHALL BE REQUIRED WHEN A ROOF SLOPE CONTAINING PANELS,MODULES OR ARRAYS IS LOCATED NOT MORE THAN 24 INCHES(610MM) VERTICALLY FROM AN ADJOINING ROOF WHICH CONTAINS AN ACCESS ROOF SCALE` R324.1.6 ROOFS WITH VALLEYS-PANELS AND MODULES SHALL NOT BE LOCATED LESS THAN 18 INCHES(451 MM)FROM A VALLEY N.T.S. EXCEPTION(S) I. ROOFS WITH SLOPES OF 2 UNITS VERTICAL AND 12 UNITS HORIZONTAL(16.6 PERCENT)AND LESS. TITLE*ROOF ACCESS PLAN R324.1.1 ALLOWANCE FOR SMOKE VENTILATION OPERATIONS-PANELS AMC)MODULES SHALL NOT BE LOCATED LESS THAN 18 INCHES(451 MM)FROM A RIDGE OR PEAK EXCEPTION(5) I. WHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED OR WHERE VERTICAL VENTILATION METHODS WILL NOT BE EMPLOYED BETWEEN THE UPPER MOST PORTION OF THE SOLAR PHOTOVOLTAIC SYSTEM AMC)THE ROOF RIDGE OR PEAK. 2. DETACHED GARAGES OR ACCESSORY STRUCTURES. A=2 I STEREO MICHA .9 J �1) i y G � UTIIJ fji z SER rn O� r� M w Yo4;'� 1 2 14 15 s . . . . . . . - _ SUNation 3 SUPPLY SIDE S..,..--Id CONNECTION SOLAR EDGE SE10000N-US INVERTER SUNATION SOLAR SYSTEMS OPTIMIZER UNGROUNDED WITH Ill REMINGTON BLVD. (TYP.) MODULE J-Box INTEGRAL DC SAFETY SWITCH © ENCLOSURE 13 RONKONKOMA NY IIT9 (TYP) I 120/140 VAC I-PH SERVICE RATED IN200A1NYSERDA INSTALLESTRING I . . . . . . . I MAX d2 AMP O beA MIN t22K MAIN �J IN RR 4 OCPD MIN. 12K AIC PV MODULE CUSTOMER INFO (TYP.) I SUWVAN RESIDENCE STRING OF (15)SOLARIA POWERXT-355R-PD W/ I— 625 DEAN DRIVE (15)OP-310 CURRENT LIMITING OPTIMIZERS I CUTCHOGUE 11935 1 ws IN SERIES CIRCUIT. 14 15F I 2 I 4 �1 JOB NUMBER 7P 20A 191 22 DC AC G SENSE i INPUT OUTPUT L �,� DATE - 3.6.19 MAIN SERVICE I PANEL NOTES STRING 2 I. N/A STRING OF (15)SOLARIA POWER)KT-355R-P0 W/ (15)OP-310 CURRENT LIMITING OPTIMIZERS IN SERIES CIRCUIT I BUILDING CONDUIT AND CONDUCTOR SCHEDULE GROUNDING TAG DESCRIPTION OR CONDUCTOR NUMBER OF CONDUIT CONDUIT RUN ELECTRODE CONDUCTOR TYPE GAUGE CONDUCTORS TYPE SIZE LENGTH I rYPE MC 10 4 N/A N/A 45' 2 HWN-2 6 3 PVC SCH. 80 1.25" 2 GC/GEC 6 I PVC SCH. 80 1.25" 2 3 HWN-2 6 3 PVC SCH. 80 1.25" 8 4 EC 6 I PVC SCH. 80 0.50" 6 DRAWN B7 KEVIN MANGIN SCALE N.T.S. TITLE:ONE-LINE DIAGRAM E- 1 SUNation TAG LABEL QTY. LOCATION NOTE EXAMPLES SUNATION SOLAR SYSTEMS MOY-714 ZOt�NEC 060.311ON71 III REMINGTON BLVD. O 12 DC CONDUITS 1 A EVERY SEPERATION BY ENCLOSURES/WALLS/ RONKONKOMA NY 11115 ;,m-• -,_ PARTITIONS/GEIUNGS/FLOORS OR NO MORE THAN 10' O NYSERDA 4355 I l6)5-320 20t44EC��33(E)(2) NSTALLER NUMBER 1 I SPUCE/COMBINER 1 A ANY COMBINER BOX IF USED CUSTOMER INFO DO NOT DISCONNECT SULUVAN RESIDENCE UNDER LOAD 625 DEAN DRIVE 105102 2014 NEC ON 17(E) CUTCHOGUE 11935 �L`�WARNING JOB NUMBER DTIM 480 EIECiRIC SHOCK HAZARD ,9122 °D NOT tOUCN hBNWALS - 730-9454 _ 1510-19,454 LOAD SIDES YAC BE ENERDNED Sul. DATE IN T1$OPEN PONTION I OF EACH A INTEGRATED DG DISCONNECT __ 7 3,16,19 DG DISCONNECT COMPLETE VOLTAGE AND CURRENT VALUES ON NOTES 0&104:2014 NEC e90-M&F DISCONNECT LABEL • -^ WARNfK HAZAW D AS NEEDED ����G A.4 -s THE OC CONDUCTORS OF - rM PHOTOVOLTAIC SYSMM ARE UNG111j"0E A110 y MAYBE ENERGIZED MR-717:2014 NEC 810 58 C _ 4$' I O INVERTER I OF EACH is SOLAR EDGE SE10000A-US • GF NSW AFFIX AT THE DISCO HANDLE D r • OW102.2014 NEC F9017(E) • as. WARNING alk— ELECTRIC SHOCK HAZARD DO NOT MUCH RRNINALS AC SERVICE I OF EACH A FUSED AC DISCONNECT DisconnectService TE waa ON BOTN THE Us,E AAD D LOAD SMS UAY K ENERIGIM I DISCONNECTING COMPLETE VOLTAGE AND CURRENT VALUES ON of 2INYK f! MEANS DISCONNECT LABEL Primary Service Disconnect Located in Main Service Panel B SECOND SERVICE DISCONNECTING MEANS • Building Isequipped with an IMorwra ectad Ebctric Power C Production Source 11 1 1 swv ti. S.I.,lasses.Veneto W: We®emielare �' eeewe e.wr ue.� 1wa iwr lx W. O •1" �"�.,, I MAIN DISCONNECT I OF EACH 0 BUILDING MAIN DISCONNECT PANEL ue o ss� PANEL I Service DiGcornect E � MI —— DRAWN BY � • �. This Buildng Is equipped with an --- KEVIN MANGIN Intercona"d Eli Po" Production Source SCALE: 1 1 1 1 N.T.S. O �+mow I UTILITY METER 1 A PSEfG UTIUTY METER 0-M mft$�._ F TITLE:LABELING SCHEMATIC dot lase Masai_ •I•tL= e•eawTs _ .wr•e.wee o.r• .// :�L `"A1��'••• - - � .. ',"�.'" -s-..t. _.. Twp-.. �� • :tel- - - • n. r ... - , +•. w' ► s .N �,! �, i � • � i A war j .. _ s �^� — -.,_ -zr�,:._ �'�`��. '`�.�'''�` �,, :•�. #ra-,' * +fir ►' I; �� � � ;,+^'^ w��j Z WO if tj �. ; 1`"•"_ �. _ moi` I � �I n aSAW' I , SOLARIA Solaria PowerXT Residential ........................... . Al Achieving up to 20% efficiency, Solaria PowerXT solar modules are one of the highest power modules in the residential solar market. Compared to conventional modules, Solaria PowerXT modules have fewer gaps between the solar cells, this leads to higher power and superior aesthetics Solaria PowerXT residential modules are manufactured with black backsheet and frames, giving them a striking appearance Developed In California, Solaria's patented cell cutting and module assembly takes processed solar wafers and turns them into PowerXT solar modules The process starts by creating a highly reliable PowerXT cell where busbars and ribbon interconnections are eliminated Solaria then packages the cells into the PowerXT solar module, reducing inactive space between the cells All of the above leads to an exceptionally efficient solar module produced in a cost effective manner Higher Efficiency, Higher Peer Solaria PowerXT modules achieve up to 20%efficiency,conventional modules achieve 15%—17%efficiency Solaria PowerXT modules are one of the highest power modules available Lower System Costs Solaria PowerXT modules produce more power per square meter area This reduces installation costs due to fewer balance of system components Improved Shading Tolerance Sub-strings are interconnected in parallel,within each of the four module quadrants, which dramatically lowers the shading losses and boosts energy yield Improved Aesthetics Compared to conventional modules,Solaria PowerXT modules have a more uniform appearance and superior aesthetics Durability and Reliability Solder-less cell interconnections are highly reliable and designed to far exceed the industry leading 25 year warranty About Solaria Established in 2000,The Solaria Corporation has created one of the industry's most respected OQPERFORMF IP portfolios, with over 100 patents encompassing materials, processes, applications, 2017 a products,manufacturing automation and equipment. Headquartered in Fremont,California, _ __ __ __G____ DNV L TUVRheinland Solaria has developed a technology platform that unlocks the potential of solar energy PV MODULE allowing it to be ubiquitous and universally accessed RELIABRJTy SCORECARD Precisely Right. The Solara Corpita.ior!6200 Paseo°afire Parkway Fremont,CA Q45H P (510)270-25,10 www solar:a.Com Cooyngh' 2018 The Solara Coiporat lon Pfoducl sppr:i;Catior's are ubiert lc,cf)ar:pe wwlllou',noti(e Rev 1 H 06 19-2x'10 Solaria Powe�XT"' -3558-M SOLARIA solaria PowerXT'-'-350R-BD «t:. ;„::. >... i••:=;:.;::. •y,:,x, ,o �s,'.,,�:xa}; Ff<{, :>ti; ': rn� `; :: @ 'i"3'a.i':is .:. x„3f,.,£,�,:.<. .. .�::::;y:i,j:•".'•.:....:.. .:'c yy{:r'.F'':, .a >�[":i•. .: � 4' �.,�,`.• •i, .••�.:'3 3' t`�'"`�::.\�.. E'.,;�,.i�y;„�' ' `.{;F; �da,,.ts ?k,. ,� '.1. .:. :, ,. �:.:. �. .•r:S.o's:.' .;'';.;, '',' „;r:..„r�. sE:RF=?`.:;:,”. :, � ,.�x E3t��f.�'S�'iY'a:� '��M. i..lw... .... ... .... .rt.i v 'st>":. •• _..,.. .. .. ..., .'�;��>:�£�'%',{,.: > Solaria PowerXT 345R-BD 350R-BD 35OR-PD 355R-PD Cell Type Monocrystalline Silicon Max Power(Pmax) [W] 345 350 350 355 Dimensions(L x W x H) 1621 mm x 11 16m x 40mm Efficiency [%] 19 1 194 194 19 6 Weight 21 kg/46 Ibis Open Circuit Voltage(Voc) [V] 47.1 474 47 1 474 Glass Type/Thickness AR Coated,Tempered/3.2mm Short Circuit Current(Isc) [A] 940 9.44 949 9 53 Frame Type Anodized Aluminum Max Power Voltage(Vmp) [V] 389 39.2 38.8 39.1 Cable Type/Length 12 AWG PV Wire(UL)/1000mm Max Power Current(Imp) [A] 8 88 8 94 902 9 09 Connector Type Amphenol H4(MC4 compatible) Power Tolerance -0/+3 -0/+3 -0/+3 -0/+3 Junction Box IP67/4 diodes „ w Front Load(UL 1703) 5400 Pa/113 psf* Rear Load(UL 1703) 2400 Pa/50 psf* Max Power(Pmax) [W] 255 258 259 261 Refer to Solaria Installation Manual for details Open Circuit Voltage(Voc) [V] 443 446 443 446 >•r; Short Circuit Current(Isc) [A] 7 61 7 61 7.69 7 68 q, Max Power Voltage(Vmp) [V] 35.8 36 1 35.7 36 0 Certifications UL 1703/IEC 61215/IEC 61730/CEC Max Power Current(Imp) [A] 7 10 7.15 722 727 CAN/CSA-C22.2 Fire Type(UL 1703) 1 Power&Product Warranty 25 years* NOCT [°C] 45+/-2 'Warranty details atwww.solaria.com Temp.Coeff of Pmax (%/ C] -0 39 _ 3.6,:£;�"�`�'�. '�:�.�='�t,.:<,.;;.:,�. ; `;��:• :::F;-,;, .. .,.,. Temp Coeff of Voc I%/°C] -0.29 Temp Coeff of Isc "Cl 004 Stacking Method Horizontal/Palletized Pcs/Pallet 25 Pallet Dims 1668 x 1150 x 1230 mm Operating temperature ^ ` [°C] 40 to+85 Pallet Weight 590 kg/1300 lbs Maxallets/40-ft Container 28 ax System Voltage [V] 1000 Max Fuse Rating [A] 15 Pcs/40-ft Container 700 Bypass Diodes [#] 4 10 1000 W/m' 1"'s g 1 -i sstrun .arimn, i e 800 W/m° 5mm A s e A 7 Z 5 600 W 5 i l l omm3 p (X i 1 U 4 400 W/m'` 3 2 ., __ 200 W/mZ NEGATIVE(-? PUSIT:VE I+) •000 13.3 fl)— WOO(3.3 ft) 1 0 0 5 10 15 20 25 30 35 40 45 50 VOLTAGE IV) AB A Authorized Dealer �""_;” _ • 3a2mm ; 000:+•.-- 7-10---7d;t:0-103C4111 \ C 4.5-10:gin,THRL AL: 4.<MOUNT NG SLOTS'B AGROUND A 10 Armin 7tw, (0.34in [o.3in] t 40.Omm 1.57in J MOUNTIMGH{1LE 1011111171 I.lmm :— 35.0,rnm Y [0.4in] {0.0Jin, (t.313m1 'he Solaria Corporatior 6200 Paseo Padre Pari way,Fremort,CA 94555 P (5 u)27u-2500 www solaria cor, Copyright 20'g The Solaria Corporahor Plodur. s:ecificat ons are sut)rct to dlange=rr+bout notice Rev 1 H 00 9 2018 solar=ee z • Single Phase Inverter with HD-Wave Technology • for North America SE300OH-US/ SE3800H-US/ SE5000H-US SE6000H-US/SE7600H-US/SE10000H-US I SE1140OH-US $ w lei •S�i a. �K 0 _ r ;x a "ftxelvafte kwerterfar longer strings grated"arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690.1.1 and 690.12 U1.1741$A certified,for CPUC Rule 21 grid compliance * Extremely small = High reliability without any electrolytic capacitors = Built-in module-level monitoring €IWI Outdoor and indoor installation wave = Optional:Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) iNthv' .`:,i edge US SO l a r • • Single Phase Inverter with HD-Wave Technology for North America SE3OOOH-US/ SE380OH-US / SE5OOOH-US/ SE60OOH-US/ SE760OH-US/ SE1O0O0H-US/ SE1140OH-US H 3 r_ - S iE0LiS 1400H-USSE3000HUS S800H US _ _ OUTPUT _ __ Rated AC Power Output 3000 3800 @ 240V 5000 6000 @ 240V 7600 1 10000 1 11400 VA 3300 208V 5000 @ 208V E 3800 @ 240V 6000 @ 240V I Max.AC Power Output 3000 3300,E 208V 5000 208V 5000 1 7600 1 10000 11400 VA . . @ AC Output Voltage Min.-Nom.-Max. f ✓ ✓ Vac (183-208-229), AC Output Voltage Min.-Nom.-Max. ✓ ✓ ✓ ✓ ✓ Vac .(211-240-264)_ k AC Frequency(Nominal) 59.3-60-60.5" Hz Maximurn Continuous Output Current 16 24 A 208V Maximum Continuous Output Current V 240V 12.5 16 21 25 { 32 i 42 i 47.5 A GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 ? 11800 15500 17650 W Maximum DC Power @208V 5100 - 7750 i ' Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V 9 - 13.5 i Maximum Input Current @240V 8.5 10.5 13.5 16.5 1 20 27 30.5 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kn Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional'=' Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA 022;2,Canadian AFCI according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) EmissionsFCC Part 15 Class B ___...__.._.._.._.._.._. _.._.._.._. ._. ._.._.._.__._.._.._..__- --- --._._-_.._. INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 3/4"minimum/14-6 AWG 3/4"rninimurn/14-4 AWG DC Input Conduit Size/#of Strings/ 3/4"minimum/1-3 strings/ r 3/4"minimum/1-2 strings/14-6 AWG AWG Range 14-6 AWG 21.3x14.6x7.3/540x370 Dimensions with Safety Switch(HxWxD) 17 7 x 14.6 x 6.8 /450 x 370 x 174 x 185 in/mm E Weight with Safety Switch 22/10 25.1/11.4 26.2/111.9 38.8/17.6 Ib/kg Noise <25 <50 dBA Cooling Natural Convection j Natural convection Operating Temperature Range 13 to+140/-25 to+60"i(-40'F./-40'C option)"' F/°C Protection Rating NEMA 313(Inverter with Safety Switch) For other regional settings please contact SolarEdge support Revenue grade inverter P/N SExxxxH-USOOONNQ For power de-rating information refer to.https//www solaredge com/sites/default/files/se-temperature-derating-note-na.pdf (41-40 version P/N SExxxxH-USOOONNU4 • solars e SolarEdge Power Optimizer Module Add-On For North America P320 / P370 / P400 / P405 / P505 • g t. wa k .h �� ...,.,,....>..............y.......�...,. ��.,.,.,:,.....,�..��.�.�:;s::,e,gin a s,,r,,,�r'.,....r1�;ik\.'::�:.r:.` � .a�$•:"'i;i�,�•�. .; I• wa:. ;� ,..$.�.. *� Witigotres all types of.module mismatch losses,from manufacturing tolerance to partial shading Flexible system design for maximum spate utilization • Fast Installation with a single bolt Next generation maintenance with module-level monitoring Compliant with art fault protection and rapid shutdown NEC requirements(when installed as part of the SolarEdge system) Module-level voltage shutdown for installer and firefighter safety taP. , _"N 1� R,.. a 3. D So I a r ' • • z SolarEdge Power Optimizer Module Add-On for North America P320/ P370/ P400/ P405/ P505 (for higher-power P320 P370 P400 60 and 72-cell P505 OPTIMIZER MODEL (for high-power (for 72&96-cell mpatibili (for thin film (for higher (typical module coty) i 60-cell modules) modules) modules) modules) current modules) INPUT Rated Input DC Power"' 320 370 400 405 1 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 125 83 Vdc MPPT Operating Range 8-48 8-60 8-80 12.5-105 1 12.5 83 Vdc Maximum Short Circuit Current(Isc) 11 10.1 14 Adc Maximum DC Input Current 13.75 12.63 11.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) _ Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1±0.1 Vdc Optimizer STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximurn Allowed System Voltage i1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase Inverters Dimensions(W x L x H) 128x152x28/5x5.97x1.1 128x152x36/ 128x152 x50/ 128x152x59/ mm/in 5x5.97x142 5x5.97x1.96 5x5.97 x2.32 Weight(including cables) 630/1.4 750/1.7 845/1.9 1064/2.3 gr/Ib Input Connector MC4121 Output Wire Type J Connector Double Insulated;MC4 Output Wire Length 0.95/3.0 1.2/3.9 m/ft Operating Temperature Ran&e -40-+85/-40-+185 `C/°F Protection Rating IP68 J NEMA6P Relative Humidity 0-100 % Gated STC power of the module.Module of up to+5%power tolerance allowed for other connector types please contact SolarEdge PV SYSTEM DESIGN USING SINGLE PHASE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTERiaf(') HD-WAVE Minimum String Length P320,P370,P400 8 10 18 (Power Optimizers) P405/P505 6 8 14 Maximum String Length 25 25 50'5j (Power Optimizers) 5700(6000 with Maximum Power per String SE7600H-US, 5250 6000 12750 W SE10000H-US) Parallel Strings of Different Lengths or Orientations Yes 13'For detailed string sizing information refer to http//www solaredge com/sites/default/files/stnng_s¢mg_na pdf i°It is not allowed to mix P405/P505 with P320/P370/P400/P600/P700/P800 m one string. 0A string with more than 30 optimizers does not meet NEC rapid shutdown requirements,safety voltage will be above the 30V requirement M'. v Entire Mounting System from «► Snap-in features make the Single Manufacturer under 1 install process intuitive and Warranty `` ' fast Industry Leading Technical UThe Most Comprehensive UL Support Services for Every 2703 Listing in the Industry Customer The SnapNrack Series 100 Roof • is designed to provide the lowest total install cost of any residential mounting The top-of-the-line features of the SnapNrack mounting system reduce install times and labor cost while eliminating the need for service calls creating the lowest install lifecycle cost of any mounting system. Wire Management • Products such as the standard rail channel keep wires neatly organized providing a clean finished look to every install • Industry's largest offering of wire management accessories include snap in junction box, 4-wire and trunk cable clamps, as well as conduit clamps for both composition shingle and the roofs. Undeniable Aesthetics • Render the mounting system invisible by using Universal End Clamps that fasten modules while remaining hidden underneath the array • Array skirt provides a sleek look and attractive design to the front of the array • Rail-based system provides rigid structure tucked away underneath array with no unsightly mounts at the top or bottom , Quality. Performance . Innovation . SnapNrack solutions are focused on simplifying the installation • products and the best wire management in the industry. SnapNrack Solar Mounting Solutions . • www.snapnrack.com . . -s Snaprack- Series 100 Solar Mounting Solutions Flashed L Foot Reliable & Weatherproof Roof Attachment . . required installation time . _ . . . UL . standard RESOURCES snapnrack.com/resources DESIGN snapnrack.com/configurator WHERE TO BUY snapnrack.com/where-to-buy SnapNrack Series 100 Flashed L Foot Kit • is an industry-leading, weatherproof solution for attaching to composition shingle roofs. The Flashed L Foot provides a fully flashed method for mounting the SnapNrack Series 100 system. The combination of Series 100 and the Flashed L foot is guaranteed to improve labor times and ensure the highest quality install possible. Flashing • Available in black galvanized steel or aluminum for enhanced corrosion resistance • L Foot is attaches to bottom edge of flashing, removing the need for shingle cutting po • Innovative stamped features provide p increased rigidity L Foot • Engineered for maximum adjustability with the ability to orient in any direction • Vertical adjustability up to 3" using available spacers L Foot Base Oft • Provides a long lasting watertight seal over the life of the system that does not rely on rubber (elastomeric R seals) that will degrade over time • Easily installs with off-the-shelf lag screws ChannelNut Provides snap-in installation to the rail channel with no drilling required • Wide range of adjustability due to sliding ability in rail prior to final tightening Quality. Performance , Innovation . , SnapNrack solutions are focused on simplifying the installation experience through intuitive prod- . • the best wire management SnapNrack Solar Mounting Solutions . • www.snapnrack.com • • snapnrack.com