Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
43455-Z
zrau Fftlt Town of Southold 11/7/2019 P.O.Box 1179 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 40838 Date: 11/7/2019 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 165 Peconic Ln., Peconic SCTM#: 473889 Sec/Block/Lot: 75.-5-14.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/1/2019 pursuant to which Building Permit No. 43455 dated 2/7/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS TO AN EXISTING ANIMAL SHELTER BUILDING AS APPLIED FOR The certificate is issued to Town of Southold of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 43455 08-09-2019 PLUMBERS CERTIFICATION DATED Authorize ature u� Town of Southold 11/7/2019 P.O.Box 1179 W� 53095 Main Rd 91 * jfi Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 40839 Date: 11/7/2019 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 165 Peconic Ln., Peconic SCTM#: 473889 Sec/Block/Lot: 75.-5-14.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/1/2019 pursuant to which Building Permit No. 43455 dated 2/7/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: GROUND MOUNTED SOLAR PANELS AS APPLIED FOR The certificate is issued to Town of Southold of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 43455 08-09-2019 PLUMBERS CERTIFICATION DATED Au orized Signature TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY f BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 43455 Date: 2/7/2019 Permission is hereby granted to: Town of Southold Attn: DPW 53095 Route 25 Southold, NY 11971 To: install roof-mounted solar panels on existing animal shelter building and construct ground-mounted solar panels. At premises located at: 165 Peconic Ln., Peconic SCTM # 473889 Sec/Block/Lot# 75.-5-14.1 Pursuant to application dated 2/1/2019 and approved by the Building Inspector. To expire on 8/8/2020. Fees: Total: $0.00 f� i Spector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2 Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 D te. ►7 New Construction: Old or Pre-existing Building: (check one) Location of Property: ,5– — ` House o. Street Hamlet Owner or Owners of Property: Suffolk County Tax Map No 1000, Section Block `.S Lot �7 Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary bficate Final Certificate: (check one Fee Submitted: $ Applic t Signafre OF SOUryOlo Town Hall Annex ~ Telephone(631)765-1802 54375 Main Road Fax (631)765-9502 P.O.Box 1179 CA Southold,NY 11971-0959 �l • �O sear.devlinCaD-town.southold.ny.us �CUUNT`I,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Town of Southold Address. 165 Peconic Ln city peconic st: NY zip 11958 Building Permit#, 43455 section: 75 Block: 5 Lot: 14.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor* DBA: SUNation Solar Systems Inc. License No- 33412-ME SITE DETAILS Office Use Only Residential Indoor Basement Service Only Commerical X Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph X Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel 480V A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer 150 Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect X Switches Twist Lock Exit Fixtures �] TVSS Other Equipment: 4- 60A 3pole Breakers, 1- 20A 3pole Breaker, 15A s.p. Breaker, Utility Disconnect, 480V Panel, 150KVA Transformer Notes: Inspector Signature: Date: August 9, 2019 S Devlin-Cert Electrical Compliance Form.xls OF SOUTyo / !7 4Y 57 5 # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION ( ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: &stg: iy D DATE ZZ ANSPECTOR Fisher Engineering Services, P.C. PO Box 30 . Oakdale •New York 11769 Phone: (631) 563-9028 November 4, 2019 NOV - 6 2019 Town of Southold Building Department Post Installation Certification Subject: Engineer Statement for Solar Roof Installation Residence: Southold Animal Shelter- 165 Peconic Lane, Peconic Permit No. BP 43455 Installation Inspection Date. 11/01/2019 The roof mounted photovoltaic system at the above referenced residence has been generally observed to be installed properly in accordance with the approved plans and is certified by Fisher Engineering Services, P.C. to be in compliance with the minimum requirements of the Town, the 2017 NYS Uniform Code, 2017 NYS Uniform Code Supplement, 2015 International Residential Code (2015 IRC), Long Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code 2014, and the provisions of ASCE 7-10. NEIGy h Sincerelyr William G. Fisher, P.E. Licensed Professional Engineer Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections FIELD INSPECTION REPORT DATE COMMENTS b FOUNDATION (IST) , ------------------------------------ 'FOUNDATION (2ND) — z 6' 0 ROUGH FRAMING& PLUMBING y 1 INSULATION PER N.Y-. y STATE ENERGY CODE FINAL ADDITIONAL COMMENTS a o C,/)m . �3 on on z TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUPCLDINCVEPARTMENT r "1111 Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX:(631)765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. LJ55- Check Septic Form N.Y.S.D.E.C. Trustees C.O Application la Flood Permit Examined 2J ,20 Single&Separate Stone-Water Assessment Form Contact: Approved 201 Mail to:SUNation Solar Systems,Inc Disapproved a/c 171 Remington Boulevard,Ronkonkoma NY 11779 Phone:(631)750-9454 Expiration 20 ild pector APPLICATION FOR BUILDING PERMIT (J INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Law%Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulatiomhs,and to admit authorized inspectors on premises and in building for necessary inspections. /� 4ewl (Signature ofaipplicant r name,if a corporation) SUNation Solar Systyrhs,Inc 171 Remington Boulevard,Ronkonkoma NY 11779 (Mailing address ofapplicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder SUNation Solar Systems,Inc-Contractor Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer Scott Maskin-President (Name and title of corporate officer) Builders License No.44104-H Plumbers License No. N/A Electricians License NO.33412-ME Other Trade's License No. 1. Location of land on w h proposed wo$will be don . House Number Street Hamlet County Tax Map No. 1000 Section Blocks Lot � � Subdivision Filed Map No. Lot A 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Residence b. Intended use and occupancy Residence with addition of Solar Panels 3. Nature of work(check which applicable): New Building Additio _ Alteratio ✓ Repair Removal Demolition Other orkS (Description oW,Panels — 4. Estimated Cost Fee $200.00 (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law,ordinance or regulation?YES NO x 13. Will lot be re-graded?YES NO Will xcess fill be removed from premises?YES-NO x � -Tryc�a � - 14. Names of Owner of premises =V ✓Address�.�5 j/'e.)j j!!,.6A1 Phone Na( Name of Architect wllham G Esher Address PO 13M 30,Oakdale,NY 11789 Phone No 631-7864419 Name of Contractor SUNation Solar Systems,Inc Address 171 R—i, -13-1 r,Ro,kmkoma NY Phone No, 631a5a9454 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO x *IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland?*YES NO x *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17 If elevation at any point on property is at 10 feet or below,must provide topographical data on survey 18.Are there any covenants and restrictions with respect to this property?*YES NO x *IF YES,PROVIDE A COPY. STATE OF NEW YORK) r^ fi COUNTY Scott Maskin-President-SUNation Solar Systems,Inc. being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the contractor (Contractor,Agent,Corporate Officer,etc) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; d that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me t ' 20 o ubl' Sig ture o Applicant L. NOTARY PUBLIC, State of Now Vbrk No. 01 DE6009594 OualiCommission IExp Expires June 29,20 Scott A. Russell ,�d°S"WQ'r 5TORMWA\T]E]k SUPERVISOR Z MANAGEMENT SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 Town of Southold 0� CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT INVOLVE ANY OF THE FOI,WWING: Yes No CHECK ALL THAT 1\PPLY1 ❑aA. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ff"B. Excavation or filling involving more than 200 cubic yards of material ❑iwithin any parcel or any contiguous area. c. Site preparation on slopes which exceed 10 feet vertical rise to ❑[33/ 100 feet of horizontal distance. D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑ E. Site preparation within the one-hundred-year floodplain as depicted on FIRM Map of any watercourse. ❑ dF. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department witFyour Building Permit Application. APPLICANT. (Pr�ner,Desi Profes tonal.Agent.Contractor other) S.C.T.M. ": 1000 Date: yy Dutnct NAME �7 / /l.Sj / t / P,un a coon Block Lot Contact Information: FOR BUILDING DEPARTMENT USE ONLY **** � TWpl—N..b,, Reviewed By: - - - - - - - - - - - - - - - - - - Date: Cj — C] Property Address/ Location of Construction Work: — — — — — — — — — — — — — — — Approved for processing Building Permit. Stormwater Management Control Plan Not Required. f � ���- �� ���� ❑ Stormwater Management Control Plan is Required. (Forward to Engineering Department for Review.) FORM * SMCP-TOS MAY 2014 FF04 BUILDING DEPARTMENT- Electrical /ctor TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 • Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roger.richert(cDtown.southold.ny.us APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: Company Name: Name: License No.: email: J/ Address: �� j Phone No.: — G JOB SITE INFORMATION: (All Information Required) Name: Address: Cross Street: Phone No.: _ • Bldg.Permit#: �j email: Tax Map District: 1000 Section: Block: Lot: BRIEF DE CRIPTI N OF WORK Please Pr7 t Clearly Circle All That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On Temp Information: (Ali information required) Service Size 1 Ph 3 Ph Size: A # Meters Old Meter# New Service - Fire Reconnect- Flood Reconnect- Service Reconnected - Underground - Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 62-Request for Inspection Form As r of saUryo �o Town Hall Annex 41 4 0011802 t� 54375 Main Road c�+ r0 er.richert �`� old.n .us 1 P.O.Box 1179G Southold,NY 11971-0959LJ jJf APR 1 6 2019 BUILDING DEPARTMENT TOWN OF SOUTHOLD T. APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Kaitlyn Sheehan Date: 04/09/19 Company Name: SUNation Solar Systems, Inc. Name: Scott Maskin License No.: 33412-ME Address: 171 Remington Blvd, Ronkonkoma, NY 11779 Phone No.: 631-750-9454 JOBSITE INFORMATION: (*Indicates required information) *Name: Southold Animal Shelter *Address: 165 Peconic Lane Peconic *Cross Street: Main Road *Phone No.: 631-765-1560 Permit No.: q 3 L �S5 Tax Map District: 1000 Section:_ -7 Block: ; Lot: / f`j *BRIEF DESCRIPTION OF WORK(Please Print Clearly) 225A 480Y/277V MLO PPV Distribution Panel, NEMA 3R, 3 Phase /4 Wire Fused - o e ZbUV Service (Please Circle Ali That Apply) *Is job ready for inspection: (ja/ NO Rough In Final *Do-you need a Temp Certificate: NO Temp Information(if-needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Undergroundmba�Meters hangeof Service Overhead Additional information: PAYMENT DUE WITH APPLICATION X82-Request for Inspection Form �J�p� New York State Insurance Fund Workers'Compensation&Disability Benefits Specialists Since 1914 199 CHURCH STREET,NEW YORK,N.Y 10007-1100 CERTIFICATE OF WORKERS' COMPENSATION INSURANCE � D 31. C = AAAAAA 753118816 SUNATION ROOFING SERVICES INC 171 REMINGTON BOULEVARD ' RONKONKOMA NY 11779 SCAN TO VALIDATE AND SUBSCRIBE POLICYHOLDER CERTIFICATE HOLDER SUNATION SOLAR SYSTEMS INC TOWN OF SOUTHOLD 171 REMINGTON BOULEVARD 54375 ROUTE 25 RONKONKOMA NY 11779 SOUTHOLD NY 11971 POLICY NUMBER CERTIFICATE NUMBER POLICY PERIOD DATE Z2160 670-2 482687 01/01/2019 TO 01/01/2020 1/31/2019 THIS IS TO CERTIFY THAT THE POLICYHOLDER NAMED ABOVE IS INSURED WITH THE NEW YORK STATE INSURANCE FUND UNDER POLICY NO 2160 670-2, COVERING THE ENTIRE OBLIGATION OF THIS POLICYHOLDER FOR WORKERS' COMPENSATION UNDER THE NEW YORK WORKERS' COMPENSATION LAW WITH RESPECT TO ALL OPERATIONS IN THE STATE OF NEW YORK, EXCEPT AS INDICATED BELOW, AND, WITH RESPECT TO OPERATIONS OUTSIDE OF NEW YORK, TO THE POLICYHOLDER'S REGULAR NEW YORK STATE EMPLOYEES ONLY IF YOU WISH TO RECEIVE NOTIFICATIONS REGARDING SAID POLICY,INCLUDING ANY NOTIFICATION OF CANCELLATIONS, OR TO VALIDATE THIS CERTIFICATE,VISIT OUR WEBSITE AT HTTPS://WWW.NYSIF.COMICERTICERTVAL.ASP.THE NEW YORK STATE INSURANCE FUND IS NOT LIABLE IN THE EVENT OF FAILURE TO GIVE SUCH NOTIFICATIONS. THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS NOR INSURANCE COVERAGE UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICY NEW YORK STATE INSURANCE FUND DIRECTOR,INSURANCE FUND UNDERWRITING VALIDATION NUMBER:453899859 U-26.3 SUFFOLK COUNTY DEPT OF HOME IMPROVEMENT CONTRACTOR i SCOTT A MASKIN LABOR, BumEss NAME LICENSING& SUNATION SOLAR SYSTEMS INC CONSUMER AFFAIRS 7^�.GO44104-1-1 03/06/2008 DATE 03/0112020 This certifies that the bearer is duly licensed by the County of Suffolk SUFFOLK COUNTY DEPT OF LABOR, LICENSING&CONSUMER AFFAIRS MASTER ELECTRICIAN "ME SCOTT A MASKIN ' certifies that the S er is duty UNArION SOLAR SYSTEMS INC 5ear licensed by the `k—H—b� County of Suffolk �6iuid 33412-ME 06/2412003 ORMI "OATS 06/01/2019 SUFFOLK COUNTY DEPT OF LABOR, LICENSING&CONSUMER AFFAIRS roRK workers' CERTIFICATE OF INSURANCE COVERAGE STATE Compensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name 8 Address of Insured(use street address only) 1 b.Business Telephone Number of Insured SUNATION SOLAR SYSTEMS INC 631-737-9404 R7RNOpNM , Pfll �qARD0 1 c.Federal Employer Identification Number of Insured or Social Security Number Work Location of Insured(Only required if coverage is specifically limited to 753118816 certain locations in New York State,i.e.,Wrap-Up Policy) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Route 25 3b.Policy Number of Entity Listed in Box"l a" Southold, NY 11971 DBL243442 3c.Policy effective period 11/28/2018 to 11/27/2019 4 Policy provides the following benefits: A.Both disability and paid family leave benefits. B.Disability benefits only C.Paid family leave benefits only. 5. Policy covers: A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law. B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above. Date Signed 1/31/2019 By �Jj�%r �V0 �/f (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 4B,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board, Plans Acceptance Unit, PO Box 5200,Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (only if Box 4C or 513 of Part i has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1 Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) 111111111°°°°1°1°1°°1°11111!1°°°111°hlllll K workers'ComCERTIFICATE OF INSURANCE COVERAGE ,►Tiepensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1a.Legal Name 8 Address of Insured(use street address only) 1 b. Business Telephone Number of Insured SUNATION SOLAR SYSTEMS INC 631-737-9404 R7tpaKB �, NYU79ARD 1c.Federal Employer Identification Number of Insured Work Location Of Insured(Only required it coverage is specifically limited to or Social Security Number 753118816 certain locations in New York State,i.e.,Wrap-Up Policy) 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) ShelterPoint Life Insurance Company Town of Southold 54375 Route 25 3b.Policy Number of Entity Listed in Box"l a" Southold, NY 11971 DBL243442 3c.Policy effective period 11/28/2018 to 11/27/2019 4. Policy provides the following benefits: A.Both disability and paid family leave benefits. B.Disability benefits only. C.Paid family leave benefits only 5. Policy covers: A.All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law B.Only the following class or classes of employers employees: Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as de scribed abov/e..' Date Signed 1/31/2019 By //I//t(Signature ofinsurance carrier's authoriized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number 516-829-8100 Name and Title Richard White, Chief Executive Officer IMPORTANT- If Boxes 4A and 5A are checked,and this form is signed by the insurance carrier's authorized representative or NYS Licensed Insurance Agent of that carrier,this certificate is COMPLETE. Mail it directly to the certificate holder. If Box 413,4C or 513 is checked,this certificate is NOT COMPLETE for purposes of Section 220,Subd.8 of the NYS Disability and Paid Family Leave Benefits Law. It must be mailed for completion to the Workers'Compensation Board,Plans Acceptance Unit,PO Box 5200, Binghamton, NY 13902-5200. PART 2.To be completed by the NYS Workers'Compensation Board (Only if Box 4C or 56 of Part 1 has been checked) State of New York Workers' Compensation Board According to information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees. Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120.1 Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) 111111�11111°1°°°°°1°11°1°�!1°°� 1°IIIIIII 6a APPR VED AS NOTED DATE:2P4 B.P.8 48q-5- FEE:— BY: RETAIN STORM WATER RUNG NOTIFY BUILDING DEPARTME AT PURSUANT TO CHAPTER 236 765-1802 SAM TO 4 PM FOR THE OF THE TOWN CODE. FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE ELECTRICAL REQUIREMENTS OF THE CODES OF NEW INSPECTION REQUIRED YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF � �Vdld-Ptf►NPHNG BOARD STEES OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE" OF OCCUPANCY r Fisher Engineering Services, P.C. PO Box 30 . Oakdale •New York 11769 Phone: (631) 563-9028 December 24, 2018 Attention: Building Department Subject: Engineer Statement for Solar Roof Installation Southold Town Animal Shelter- 165 Peconic Lane, Peconic,NY 11958 1 have verified the adequacy and structural integrity of the existing roof rafters along with the proposed ground-mount structure for installation of the solar collector system (photovoltaic system) and its construction satisfies the structural design load requirements of the 2015-International Building Code, Long Island Unified Solar Permit Imitative (LIUSPI), and National Electric Code 2014. I have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic system for the above structure meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting, the rails shall be securely anchored to the rafters utilizing lag screws that have been designed for wind speed criteria of 130 mph and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geographic design criteria are not applicable to this solar installation. The installation shall be in accordance with the minimum requirements certified by this letter for the proposed installation on the structures shown on the accompanying plans. There are no structural modifications planned or required for the existing roof. I hope that this letter serves and meets with the approval of the Building Department. Sincerely, William G. Fisher, P.E. Licensed Professional Engineer Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections scz 0 • • UP TO 60%FASTER INSTALLATION FOR COMMERCIAL PV SYSTEMS • Fully integrated increased power,flexibility Enhanced safety,reliability Smart monitoring,control,service •Innovative design requires no -Multiple power ratings for small -Integrated SunSpec PLC signal -Advanced smart inverter grid support additional racking For rooftop to large scale commercial PV for module-level rapid shutdown capabilities installation installations compliance to 2017 NEC -Increased R01 with SMA ennexOS cross *Integrated DC and AC disconnects -Six MPP trackers for flexible stringing -Next-gen DC AFCI arc4ault sector energy management platform and overvoltoge protection and maximum power production protection certified to new -SMA Smart Connected proactive O&M * 12 direct string inputs for reduced -OPHTrac'm Global Peak shade Standard UL 1699B solution reduces time spent diagnosing and labor and material costs tolerant MPP tracking servicing in the field SUNNY TRIPOWER CORE1 33-US / 50-US / 62-US It stands on its own The Sunny Tripower CORE1 is the world's first free-standing PV inverter for commercial rooftops,carports,ground mount and repowering legacy solar projects.Now with expanded features and new power classes,the COREI is the most versatile,cost- effective commercial solution available. From distribution to construction to operation, the Sunny Tripower COREI enables logistical, material, labor and service cost reductions. Integrated SunSpec: PLC for rapid shutdown and enhanced DC AFCI arc-fault protection ensure compliance to the latest safety codes and standards. With Sunny Tripower COREI and SMAS ennexOS cross sector energy management platform,system integrators can deliver comprehensive commercial energy solutions for increased ROI www SMA-Americo com Technical data' Sunny Tripower COREt 33-US Sunny Tripower COREI 50-US Sunny Tripower COREI 62-US Input[DC) Maximum array power 50000 Wp STC 75000 Wp STC 93750 Wp STC Maximum system voltage 1000V Rated MPP voltage range 330 V...800 V 500 V...800 V 550 V...800 V MPPT operating voltage range 150 V..1000 V Minimum DC voltage/start voltage 150 V/188 V MPP trackers/strings per MPP input 6/2 Maximum operating input current/per MPP tracker 120A/20A Maximum short circuit current per MPPT/per string input 30A/30A Output(AC) AC nominal power 33300 W 50000 W 62500 W Maximum apparent power 33300 VA 50000 VA 66000 VA Output phases/line connections 3/3-(N)-PE Nominal AC voltage 480 V/277 V WYE AC voltage range 244 V 305 V Maximum output current 40A 64A 79.5 A Rated grid frequency 60 Hz Grid frequency/range 50 Hz,60 Hz/-6 Hz. +6Hz Power factor at rated power/adjustable displacement 1/0.0 loading 0.0 lagging HarmonicsTHD <3% Efficiency CEC efficiency(preliminary) 97.5% 98% 98% Protection and safety features Load rated DC disconnect 0 Load rated AC disconnect • Ground fault monitoring:Riso/Differential current 0/0 DC AFCI arc4oult protection 0 SunSpec PLC signal for rapid shutdown • DC reverse polarity protection • AC short circuit protection 0 DC surge protection:Type 2/Type 1+2 0/0 AC surge protection:Type 2/Type 1+2 0/0 Protection class/overvaltage category(as per UL 840) I/IV General data Device dimensions(W/H/D) 621 mm/733 mm/569 mm (24.4 in x 28.8 in x 22.4 in) Device weight 84 kg(185 lbs) Operating temperature range -25"C. +60"C (43`F...+140"F) Storage temperature range -40"C...+70"C (-40°F...+158°F) Audible noise emissions(full power Q 1 m and 25°C) 65 dB(A) Internal consumption of night 5 W Topology Transformerless Cooling Concept OptiCool(forced convection,variable speed fans) _ Enclosure protection rating Type 4X,3SX(as per UL 50E) Maximum permissible relative humidity(non-condensing) 100% Additional information Mounting Free-standing with included mounting feet DC connection Amphenol UTX PV connectors AC connection Screw terminals-4 AWG to 4/0 AWG CU/AL LED indicators(Status/Foult/Communication) • Network interfaces:Ethemet/WLAN/RS485 •(2 ports)/•/O Dela protocols:SMA Modbus/SunSpec Modbus/Webconnect 9/9/6 Multifunction relay 0 OphTroc Global Peak(shade-tolerant MPP tracking) 0 Integrated Plant COntrol/Q on Demand 24/7 0/0 Off-Grid capable/SMA Fuel Save Controller compatible 0/0 SMA Smart Connected(proactive monitoring and service support) • Certifications(pending os of June 2018 Certifications and approvals UL 1741,UL 1699B,UL 1998,IEEE 1547,CAN/CSA-C22.2 No.62109 FCC compliance FCC Part 15 Class A Grid interconnection standards UL 1741 SA-CA Rule 21,HECO Rule 14H Advanced grid support capabilities L/HFRT,L/HVRT,Volt-VAr,Volt-Watt,Frequency-Watt,Ramp Rate Control,Fixed Power Factor Warranty Standard 10 years Optional extensions 15/20 years O Optional features •Standard features -Not available 'Preliminary data as of June 2018 Type designation STP33-US-41 STP50-US-41 STP62-US-41 Accessories SMA Dela Manager M L SMA Sensor Module Universal Mounting System AC Surge Prowdion Module KB EDMM-US-10 MD.SEN-US40 UMS_KR•10 AC_SPI)�_KRl-I 0,AC_SPD_KIT2_T1M DC Surge Prosection Module Kit DC_SPD_KR410,DCSPDW5 T1T2 Toll Free+1 888 4 SMA USA www.SMA-America.com SMA America, LLC X SUNPOWER" SunPower X-Series: X21-470-COM SunPower° Commercial DC Panel Maximum Power. Minimalist Design. •iiia 1. - iii iii .• • Highest Lifetime Energy and Savings 3 v z Up to SunPower 60% Fundamentally Different. T More And Better, v Lifetime ° Enemy Years of Operation The SunPower Maxeon' Solar Cell Best Reliability, Best Warranty Lii.i:.ie,r -h -utt: ,naue '(ir "[ r crude crode i a � , As Sustainable As Its Energya �•�,I ail 'r + More • RJr Ke"! r gry?-- t: Power 1031 do 70 �',1' in Year 25 • f °.t�,;laLS -,1., �i ! _ _r-��;'o.l,l .<:c V .r'..a=,c xl :- Years of Operation • (,u'tr it) to m,ia X-Series:X21-470-COM SunPower4'Commercial DC Panel QPQ-'Q1- ,�-O;M SPn-X21-&,0-Cr'M 46 imn 2 [1 8 jn] 06'n,m _ [81 11ni " ► a 1 1 1G46 mm [41.2 in] tai FRAME PROFILE 1 x 398 mm [15 68in](E) IR� -k P ;h S,d: 9:r SUNPOWER®R SUNation J, Solar as it should be pSUNATION SOLAR SYSTEMS 171 REMINGTON BLVD. RONKONKOMA N.Y. 11111 PAP XF W #99494 NYSERDA 50 WA INSTALLER 4355 NUMBER 51�C 208Y/ 120V LIG. P.E. STAMP -OF NEW),NEW), A 45 XFMP rvP rV NM\TF1I?5 ' b 5CONNFCf 5W fCN 225A WO 50kVA SMA� NV�f?1��5 250V 450A fu5oJ -�0�� 480Y/ 277V 5MA t �3 3 kW 060tZ', w`Q 0 Irl 208Y/ 20V U1/Y� .,, 5ec 480Y/ 277V WYF �� U�"/ 4W 40A OUT @ 480VAC �X 51�NG Wea�,l�erproof NEMA-�� NEMA ��P\ UOCMP Af GI?AP� ON SMP W 4006 tran5-5 M 11- �60 A,j 3V ACC' # 3V 60 A Moser # 99 82� 750 MPM P\ 4W- 208Y/ 120V JOB NUMBER 11" �60 A, 3V 18 4(oro �J 2 �P 60 A CUSTOMER INFO SOUtHOLD ANIMAL SHELTER 2 165 PECONIC LANE O PECONIC NY 11958 60 A 3� 0 JOB NOTES �V 60 A 1. NIA NVQ Mr\ ;= 60 A 3� O �- I / OAWG GSC GSC O a I A,j IF COMM IPI5A CAMIf COMMUN CAPON CD ADDITIONAL MATERIALS 1. NIA �X 51"NG �U Ub NG bP- �X 51'NG �U Lb NG PP-2 2006 MCS 2006 MCS WIRING SCHEDULE 1201208 WYE 1201 208 WYE Rated �OCA1F,b IN %Lb NG �OCA1'r-,b IN MU Lb NG Identifier Description Ampacity Load Phase Conductors Neutral Conductor EGC size Conduit size DRAWN BY EXISTING SS 1 SERVICE 400A 2 SETS 3-1/C 3/0 AWG THWN #3/0 AWG NA 2" DATE �# I / OAWG GFC ENTRANCE 2 PV SERVICE 400 A 3-1/C 750 KCM THWN 750 KCM NA 4" REVISION(S): ENTRANCE DELTA DATE DESIGNER �1 XX.XX.XX N/A 3 XFMR FEEDER 400 A 370 A 3-1/C 750 KCM THWN 750 KCM #2/0 AWG 4" 0 XX.XX.XX N/A 0 XX.XX.XX N/A 4 PVP FEEDER 225 A 160 A 3-1/C #4/0 AWG THWN #4/0 AWG #2 AWG 2-1/2 ® XX.XX.XX N/A 0 XX.XX.XX N/A INVERTER #10 Zk, XX.XX.XX N/A CIRCUIT 60 A 40A 3C #6 AWG THWN INSTRUMENTATION #10 1-1/4" SCALE: ONLY N. T. S. (0 COMM CIRCUIT 15 A 4A 1 C #12 AWG THWN 1 C #12 AWG THWN #12 3/4" TITLE: THREE-LINE 7 COMM LINK NA NA CAT 5e NA NA 3/4" NOF 1719 KW PHOTOVOLTAIC ROOFTOP SYSTEM 60A S Solar as it should be SUNATION SOLAR SYSTEMS 171 REMINGTON BLVD. RONKONKOMA N.Y. 11119 NYSERDA L NI A ] I Il. INSTALLER 43rpE..7 DO LJ HiT 71 O NUMBER UC. P.E. STAMP X165 PECONIC LANE PECONIC N.Y. 11958 �t 4�. r., ._•..s�•�.�� a '' R .✓tn `,y , `.i/*'/��, px�YgOSc`4p„r' rl'w t 3!tx ,' .,r"�,' ” t�' _ V1'Y l *'.!. .•e / `/ .•'t.F '�. ��i _ ro+, %, g &i µt'`i• .a y t �v '", - /^ "I" $Y r +e; ! 'f•3 - .SA'S d- �u, �,y�'•,jAvi',pg / j` ,," `, '.�„, Y .p• r � e4' �4 M.• ,,w .'� '�'',•c • '^Ri'tw,•..r' .t' „v,.,eA'" �E�'• �,• ;' °� -°.,;. t,,%. � •,�_ r - .t; . .,✓ r .�'b.'' °\�, � « ,.Iwo��.`.. 41 _ • f yF n,� t ,P3�` t �' '� 6� � r� o-, wp �rµ &'!6� �., i L.w i P A. v r , -•. v % "yam ,. ', s j "'"n'"� (.'s. -} q - .y"t. x P '� 7 � .,�.* s '�.� t; �". �`�„ �' ,� �4, s r" i,n..f' - 4 r`".a,. s� �'�,•. ., Af P. ' +tT-� m '"w ,v4`, -,. .,�:,� },. P3 .. F ,r ` ,r„ i'• .+`` '+ + 'x'',• �. s�^" ` • gg ok . � 41, s• .Qa. �;, ,. .e.*.,.....,,, :•4 Y`.` .r.> ..* " c�;, .d -:,P p. `" r ti - i �`t` ..,� h' .f' ,,;o '�`M 444 pp� '""-. .'-y, .�� >I r ,.i •pia V��,,. 3:' ,��F P•.'Cw,' a` °tom ,,,neo, Rey,'. t�• ,fie..' . .,,....... .y iP +e -Me �' r< 'S !� _�: Rt' "' '° .""'• 9 ,f4n ,�`6i ti ,�..i,. ,,t,f,h*/c =...w, "" _�kr„"z_. _ •b a—�.4." vn `tom",��", "...w...—_.—.--.Q�_ _ .' , a , .'t .`�..,-� - § .^ .+.. -. <, ✓ ^ w, �` xlbne a"' 4'� .r�■ :e*','.,` f - w,.wua. °' .t '' M^ ,. 7 'z .' R °.'�. a e /' ., �' . syr ^?�! .w •w:,:'l ./ t ."'��= JOB NUMBER i• -_ ,' i _ e�'�+'-,. rT�i�. ,•;,k 1 ,r..g - .'.s ''" /r' a.. * y•" w ;� ?`f',°j],� +`. •'�.-is, tt._ . ���P .l«• �g 'y„i •tt3y _ .• .� f ,J ';�� �. .� �v'a„� 'fib.. v .. ,1� y+..,,a `�f� `� ~,t\� .3:, .�,. - aM -'.sr.t • ,`fx'4 LL'> i '6' + `'- �'?” .'� `"MM „- If. y„ �ti�` '.'t, mT / r�• All "; -an ,°5• .. P A p, . (. 15 4 ro ro ° \ ',4 .yj, .Y ri(,e.�`• °c', r -ti�' r ni ;C ` `:`' Y. .a 9 r ti (lu, t ,` P' .'"'. �L w . , ,. �: 1a ;tc ¢ , vA. �►'� r 4`� . 4 � F CUSTOMER INFO � � p.. +e�"ry, �kf.. " �, $ai C fi a c�� a\ ` �. f,•� / � �� ' ,�`',+E,...� ^ �y�', ° �5 I� 54 ,� e "`r. (}f, •�'• ¢ 5.. ;� ,.a'ceR r .A r `';: SOUTHOLD TOWN IM O �.- >� .. ,;. ,•�,- �, ,.r,.�`� �„ ANIMAL SHELTER • 'y , , '.'�^ �,,fgq" "� a'": •? a �. ,R �,^ z r '�, � ,p} �, '�. k, :' • � ;'``, � r r �� » . ., M,`' 165 PECONIC LANE .., O 'x ,- ` ` -.,<�, ° '' =: a�. ; a�F, ��; • A} PECONIC NY 11958 +,.n.,.„.,, ..»..,.,,,•..,..,«„�a�.,,,,av...,e.,.-�,....-. ,....>«.s.s,. - 'ta" • ,, 'rsc� >,,. c `; wy' }, ,. '4,,.,pkx" ' S o a m • V �o- , /t a JOB NOTES \` `• `'' 'fie@d^+�' , - ,',4.�' '� J�'„t 0 o I. N/A 0 STIREET VIEW ° o •�� ° 9®° SATE L�LITE IMAGERY O 0 O � OW P ` ' f�PP \\ ., �'�F�+e•nrn•isr-Vii,.«. .. .. ^ �'. �� .... -, c3rl tlil'f;WI"f'y i1'ri f. � -.,, ," - ,.. _. ,.., d� 'x', "�.W ._ . ..- .ye"':'.•,,.. �y� '--.,2.,—.,`.,�..'' • e4 � \ •,�” �; � far � a�y � �? a r,rnr•n,.nrt H,rbnr r. w• �f Er. ,t r,^nd R+��•3u'�nt 165 Peconic Lane Soutl'o'd Animal Shelter ff f f Southold Policeg r' Department",�+ Qa r r r. ADDITIONAL MATERIALS Seifert 1. N/A a1 ` 0 25 50 FT SITE LC"y"CATION 3D IRENDEIRM N G F J'Rx kr"J""OFA YS 0 5 10 YD DRAWN BY DESIGNED, ENGINEERED AND INSTALLED BY NENDZA SYSTEM SUMMARY DRAWING INDEX DATE MODULE (310) SPR—X21-410—COM OPTIMIZER NIA PV-TL TITLE SHEET INVERTER (4) SMA STP GORE 1 33—US STRINGING SEE PV-A3 PV-G1 GENERAL INFORMATION SHEET REVISION(S) ROOF RACKING SNAP'N'RACK DELTA DATE DESIGNER DOG PORT RACKING INHABIT PV- 7 SITE PLAN — ARRAY LOCATIONS XXXXXX N/A PACKAGE COMMERCIAL Solar as it should be SYSTEM RATING 113.9 KW DC PV-A2 ROOF ACCESS PLAN I WALK—WAYS SMOKE VENTILATION XXXXXX NIA SYSTEM SIZE 133.2 KW AG I11 REMINGT'ON BLVD. R K KOMAN.Y. 111113 EST. PRODUCTION 211,550 KWH/YR (PV WATTS) 631.150.5454 PV-A3 SITE PLAN - EQUIPMENT LOCATIONS � XXXXXX NIA ATTACHMENTS N/A PV-A4 DOG PORT PLAN ® XXXXXX NIA PROJECT DESCRIPTION � SCOPE OF WORK —TURNKEY ROOFTOP I DOG KENNEL PORT GRID TIED PHOTOVOLTAIC SYSTEM WITHOUT BATTERIES. PV-E2 DC WIRING PLAN 0 XXXXXX NIA SOLAR MODUI� SPCC —ROOF TOP: THE PANELS WILL BE MOUNTED ON A GALVANIZED STEEL WITH CLEAR ANODIZED FINISH RAIL P� © XXXXXX NIA SUPPORT STRUCTURE WITH 6000 SERIES ALUMINUM FLASHINGS FASTENED WITH STAINLESS STEEL - THREE—UNE DIAGRAM HARDWARE. THE PANELS WILL BE MOUNTED FLUSH TO THE ROOF AT NO MORE THAN 6" FROM t THE PAGE: ROOF SURFACE FACING SOUTHEAST. PV-®I SITE PI—{OTOS , O� „ CU1"(RTIC � GEOGRAPHIC DESIGN CRITERIA PV-D2- EQUIPMENT DATA SHEETS WIND DESIGN SUBJECT TO DAMAGE TITLE SHEET SUNPOWER SPR-X21-410-COM ��/. 3 LABELING PLAQUES WIND WIND ICE 41aWATT EA. SPECIAL SEISMIC COMATE FROST WINTER AIR MEAN ''I Q tt GROUND SPEED tOPOCsRAPHIG WIND EXPOSURE BORNE ��ON WEATHERING UNE TERMITE DESIGN BARRIER FLOOD FREEZING ANNUAL 8�.�//L X 41.2��U1 X �.VpD� Z2.Z9 12 SNOW LOAD (MPH.) EFFECTS CATEGORY DEBRIS ZONE NDERLAYMENT HAZARD G �j /� Q REGION ZONE CATEGORY DEPTH TEMP REQUIRED INDEX TEMP SEE rJ' 6.0#/MODULE (2.51#/S�) 12/2018 20 P5F 139 B NO C 2 C 4A SEVERE 3r-0• TO 15DEG NA PLANS 599 51 HEAVY EXAMINER BUILDING REVIEW NOTE GENERAL NOTES CONDUCTORS AND CONDUCTOR INSTALLATION Mation LEGEND THE GENERAL NOTES APPLY TO ALL DRAWINGS UNDER THE CONTRACT. REFER TO solar as It Should be COMPRESSION LUGS SHALL BE USED ON ALL ALUMINUM CABLE TERMINATIONS. TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE ENCLOSED DOCUMENT FOR INDIVIDUAL DRAWINGS FOR ADDITIONAL NOTES. MECHANICAL LUGS MAY ONLY BE USED FOR COPPER CABLE TERMINATIONS. SUNATION SOLAR SYSTEMS I MINIMUM ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SPECIFIED SYMBOL DESCRIPTION DRAWINGS ARE DIAGRAMS AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND RONKONKOMA N.Y. 111115 WORK. FOLLOW DRAWINGS IN LAYING OUT OF WORK AND CHECK DRAWINGS OF OTHER IF ALUMINUM MC CABLE IS USED, THHN/ THWN- 2 INSULATION IS ACCEPTABLE. IN THE INTERNATIONAL BUILDING CODE. TRADES TO VERIFY SPACE CONDITIONS . MAINTAIN HEADROOM, SPACE CONDITIONS, FOR ALUMINUM CONDUCTORS XHHW-2 SHALL BE USED. THIS REVIEW DOES NOT GUARANTEE COMPLIANCE WITH THAT CODE. THAT PV MODULE AND REQUIRED CLEARANCES. NYSERDA GUARANTEED UNDER THE SEAL AND SIGNATURE OF THE NEW YORK NO-LOX TO BE USED WITH ALL ALUMINUM LUGS. INSTALLER 4355 RESPONSIBILITY IS GU NUMBER PV SYSTEM CONTRACTOR SHALL COORDINATE ALL THE WORK WITH THE ENGINEER, STATE LICENSED DESIGN PROFESSIONAL OF RECORD. THE CONSTRUCTION MANAGER AND ALL OTHER CONTRACTORS TO INSURE THAT THE PV LIG. P.E. STAMP o ROOF ATTACHMENT PV SYSTEM CONDUCTORS SHALL BE MARKED AND IDENTIFIED PER NEC 690.31(B) THAT SEAL AND SIGNATURE HAS BEEN INTERPRETED AS AN ATTESTATION THAT, TO SYSTEM IS INSTALLED AS SPECIFIED IN THESE DRAWINGS. THE BEST OF THE LICENSEE: 'S BELIEF AND INFORMATION THE WORK IN DOCUMENT INSTALL WIRE AND CABLE IN ACCORDANCE WITH THE NEC AND AS HEREINAFTER SPECIFIED. F NEH . USE THE NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION'Sy y0� IS: INVERTER PERSONAL PROTECTIVE EQUIPMENT (PPE) SHALL BE PROVIDED AS REQUIRED IN ACCORDANCE WITH NEC 70E AND OSHA REQUIREMENTS. "STANDARD OF INSTALLATION", THE MANUFACTURER'S WRITTEN INSTRUCTIONS, • UNLESS SUPERSEDED BY THESE SPECIFICATIONS. IN ALL CASES THE INSTALLATION ACCURATE ` PV D I STRI BUTI 0 N PANEL UN-FORSEEN OBSTRUCTIONS ON THE ROOF MAY NECESSITATE A CHANGE IN THE SHALL BE IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. r ` LAYOUT. ANY CHANGES TO THE RACKING LAYOUT SHOULD BE REPORTED TO THE • CONFORMS WITH GOVERNING CODES APPLICABLE AT THE TIME OF THE ENGINEER. CHANGES IN UP TO 5% OF THE MODULES SHOULD BE ANTICIPATED. SUBMISSION CHANGES TO THE ARRAY LAYOUT SHOULD BE MADE AS TO NOT IMPACT THE NUMBER THE USE OF WIRE SPLICES AT ANY POINT IN THE INSTALLATION IS STRICTLY • CONFORMS WITH REASONABLE STANDARDS OF PRACTICE AND WITH VIEW TO THE TRANSFORMER OF MODULES ON A COMBINER BOX OR INVERTER. PROHIBITED. SAFEGUARDING OF LIFE, HEALTH, PROPERTY AND PUBLIC WELFARE IS THE LANDSCAPING: RESTORE TO ORIGINAL CONDITIONS . THE USE OF WIRE LUBE IS REQUIRED FOR ALL WIRE PULLS THROUGH CONDUIT RESPONSIBILITY OF THE LICENSEE ® FUSED DISCONNECT RUNS OF 20 ' OR LONGER, OR WITH BENDS IN 180 ' OR MORE. WIRE LUBE IS ALL STRUCTURAL AND MISCELLANEOUS EXTERIOR STEEL, INCLUDING STRUT STRUCTURAL STATEMENT CHANNEL (SUCH AS UNISTRUT OR KINDORF) SHALL BE CORROSION RESISTANT, HOT REQUIRED EVEN WHEN USING SELF LUBRICATING CABLES. © NON- FUSED DISCONNECT DIP GALVANIZED OR GALVANNEALED WITH A COATED FINISH MINIMUM. STRING WIRING & HOME RUNS SHALL BE SECURED TO UNDERSIDE OF THE RACKING & THE EXISTING STRUCTURE :[S ADEQUATE TO SUPPORT THE NEW LOADS IMPOSED BY MODULES USING ZIP TIES OUTDOOR RATED FOR UV. THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT & SHEAR. THE EXISTING BUILDING GROUND ROD ELECTRICAL NOTES RAFTER SIZES & DIMENSIONS CONFORM TO THE 2015 INTERNATIONAL BUILDING - ALL WORK AND MATERIALS SHALL BE IN FULL ACCORDANCE WITH THE NATIONAL PHASE RELATIONSHIP JOB NUMBER CODE AND ASCE 7-10. ELECTRICAL CODE AND SHALL BE UNDERWRITERS LABORATORIES (UL) LABELED. THE CONNECT FEEDERS TO MAINTAIN PHASE RELATIONSHIP THROUGH SYSTEM. PHASE M UTILITY METER CONTRACTOR SHALL PROCURE ALL NECESSARY CERTIFICATIONS FOR ALL WORK INSTALLED, PAY ALL FEES AND CHARGES CONNECTED THEREWITH AND DELIVER ALL LEGS OF FEEDERS SHALL MATCH BUS OR CABLE ARRANGEMENTS IN EQUIIPMENT TO 184&& MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED 2015 INTERNATIONAL CERTIFICATES AND INSPECTION APPROVALS TO THE OWNER THROUGH THE ENGINEER, WHICH THE FEEDERS ARE CONNECTED. COLOR CODING SHALL BE AS FOLLOWS: CUSTOMER INFO BUILDING CODE AND ASCE 7-10 REQUIREMIENTS. UM UTILITY METER BEFORE HIS WORK WILL BE FINALLY ACCEPTED. SOUTHOLD TOWN ANIMAL SHELTER 208/120 VAC FLUSH MOUNT / PITCHED ROOF NOTES SERVICE DISCONNECT ALL INVERTERS SHALL BE IEEE 929 COMPLIANT AND SHALL BE INSPECTED BY 165 PECONIC LANE cJ' D LOCAL UTILITY BEFORE COMMISSIONING, TESTING AND OPERATION OF THE SYSTEM. A PHASE: BLACK, B PHASE: RED, C PHASE: BLUE PECONIC NY 11958 277/480 VAC JOB NOTES 1. AN 18" WIDE CLEARING (FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED == NEW EQUIPMENT SHALL HAVE AN INTERRUPT RATING (kAIC) GREATER THAN OR MAIN SERVICE PANEL EQUAL TO THE EXISTING EQUIPMENT.MSP A PHASE: BROWN, B PHASE; ORANGE, C PHASE: YELLOW I• N/A ALONG AT LEAST ONE SIDE OF THE ROOF RIDGE ON THE SAME SIDE AS THE == SOLAR EQUIPMENT OR ON ANOTHER SIDE OF THE RIDGE THAT DOES NOT HAVE INV MANNER OF INSTALLATION 1000 VDC OR 600 VDC SOLAR EQUIPMENT ON IT. IN ADDITION, AN 18" WIDE PATHWAY (FREE OF = INVERTER UNGROUNDED POSITIVE CONDUCTOR: RED UNGROUNDED �c/Ac SOLAR EQUIPMENT) SHALL BE PROVIDED FROM AT LEAST ONE EAVE OR GUTTER ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE NEGATIVE CONDUCTOR: BLACK AC AND DC SYSTEMS: GROUNDED CONDUCTOR: WHITE GROUND : GREEN CONNECTING TO THAT 18" ROOF RIDGE CLEARING. PPV PV DISTRIBUTION PANEL MANNER BY MECHANICS SKILLED IN THE TRADE INVOLVED. ALL DETAILS OF THE INSTALLATION SHALL BE MECHANICALLY AND ELECTRICALLY CORRECT. _= WHERE COLOR CODED CABLE IS NOT USED, TAPE CONDUCTOR WITH 2. ROOF SHALL HAVE NO MORE THAN A SINGLE LAYER OF ROOF COVERING IN ,1=�5 FUSED DISCONNECT TORQUE AND MARK ALL RACKING AND MECHANICAL LUGS. ADDITION TO THE SOLAR EQUIPMENT. DS OVERLAPPED COLORED TAPE FOR A MINIMUM OF 6"IN ACCESSIBLE CONDUITS AND RACEWAYS 3. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH-MOUNTED, PARALLEL TO AG NON- FUSED DISCONNECT LOCATION S. COLOR CODING MUST BE USED CONSISTENTLY FOR THE ENTIRE AND NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. DS PROVIDE RACEWAYS MINIMUM SIZE 3/4". PROJECT. SSG SUPPLY SIDE CONNECTION ELECTRICAL ENCLOSURES 4. WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF FOR T_ CONDUITS SHALL BE EMT WHERE NOT SUBJECT TO PHYSICAL DAMAGE. CONDUITS SHALL BE IMC OR RMC WHERE SUBJECT TO PHYSICAL DAMAGE. PVC CONDUITS ONLY PHOTOVOLTAICS AND NO MORE THAN 6-PSF FOR RESIDENTIAL SOLAR HOT PERMITTED IN BELOW GRADE DUCT BANKS. ALL OUTDOOR ENCLOSURES (PANELBOARDS, DISCONNECT SWITCHES, JUNCTION WATER SYSTEMS. VP VENT PIPE BOXES, COMBINER BOXES , ETC. ) SHALL BE NEMA 3R, 4, OR 4 X. INDOOR DRAWINGS SHOW RACEWAY LOCATIONS DIAGRAMMATICALLY. CONTRACTOR SHALL ENCLOSURES SHALL BE NEMA 1. ADJUST ROUTING TO SUIT FIELD LOCATIONS. ANY CHANGES TO PROPOSED ROUTING 5. ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT (EXT.) EXTERIOR SHALL BE SUBMITTED TO ENGINEER FOR REVIEW AND APPROVAL. PANEL-BOARD DOORS SHALL BE QUARTER TURN LATCHES OR EXTERNAL HANDLE WITH ADDITIONAL MATERIALS INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A INTERNAL LATCHES , NO SETS OF EXTERNAL SCREW DOWN CLAMPS. I. NIA PLUMBING PERMIT AND INSPECTION. FURNISH AND INSTALL ALL FITTINGS AND SPECIAL DEVICES NECESSARY FOR THE CONDUIT TERMINATING IN OUTDOOR ENCLOSURES SHALL USE MYERS - TYPE HUBS (15T) 1ST FLOOR PROPER INSTALLATION, CONNECTION AND OPERATION OF THE SYSTEM. CONDUIT WITH GROUND SCREW. UTILIZE RAIN TIGHT FITTINGS FOR ALL CABLE ENTRIES. NOTES SPECIFIC TO NEW YORK ELBOWS SHALL BE OF THE SAME MAKE, QUALITY AND FINISH AS THE CONDUIT USED. (2ND) 2ND FLOOR NO PENETRATIONS OR CABLE ENTRIES IN THE TOP OF OUTDOOR ENCLOSURES. ENTER ADOPTED NEC VERSION: 2014 PROVIDE 2 PROTECTIVE COATS OF ASPHALTUM COMPOUND FOR ANY GALVANIZED OUTDOOR ENCLOSURES FROM THE BOTTOM (PREFERRED) OR SIDE. STEEL CONDUITS DIRECTLY BURIED IN EARTH. UTILITY: PUBLIC SERVICE ELECTRIC AND GAS COMPANY OF LONG ISLAND BASEMENT ALL ELECTRICAL EQUIPMENT SHALL BE LISTED OR LABELED BY A (RECOGNIZED (�) (PSE&G) EMT CONDUIT SHALL USE COMPRESS ION RAIN TIGHT CONNECTORS, FACTORY STAMPED TESTING AGENCY. DRAWN BY UTILITY DISCONNECT SWITCH REQUIREMENTS: RAIN TIGHT WITH COMPONENTS PROPERLY INSTALLED. ARC FLASH HAZARD WARNING LABELS SHALL BE PROVIDED AND MOUNTED ON EVERY NENDZA CR) ROOF COMBINER BOX, TERMINAL BOX, INVERTER, AC AND DC SWITCH, TRANSFORMER, DATE EXTERIOR AC DISCONNECT SWITCH/ISOLATION DEVICE: SMALL GENERATOR PROVIDE EXPANSION FITTINGS WITH BONDING JUMPERS FOR EVERY 100 ' OF AND SWITCHGEAR. FACILITIES SHALL BE CAPABLE OF BEING ISOLATED FROM THE EDC BY MEANS OF STRAIGHT METAL CONDUIT RUN. 12- 21 . 15 A LOCKABLE, DELTA REVISION HAND HOLES, PULL BOXES, OR CONDUIT BODIES SHALL BE INSTALLED (WHETHER REVISION(Sk VISIBLE-BREAK ISOLATION' DEVICE ACCESSIBLE BY THE EDC IN ACCORDANCE WITH CONDUIT EXPANSION AND DEFLECTION FITTINGS WITH BONDING JUMPERS SHALL BE OR NOT SHOWN ON DRAWINGS) WHEN THE RACEWAY HAS MORE THAN 360" OF BENDS, DELTA DATE DESIGNER USED WHENEVER CROSSING BUILDING EXPANSION AND SEISMIC SEPARATION JOINTS. OR AS NECESSARY TO NOT EXCEED MANUFACTURER'S MAXIMUM CABLE PULILING NEC REQUIREMENTS. THE ISOLATION DEVICE SHALL BE INSTALLED, OWNED AND Al SUNEYE LOCATION TENSION. Ot xxxxxx NIA MAINTAINED BY THE CUSTOMER - GENERATOR AND LOCATED BETWEEN THE SMALL LEAVE WIRE SUFFICIENTLY LONG TO PERMIT MAKING FINAL CONNECTIONS. ALL 0 xxxx.xx NIA GENERATION FACILITY AND THE POINT OF INTERCONNECTION. A DRAW-OUT TYPE EMPTY CONDUITS OVER 10' IN LENGTH SHALL BE PROVIDED WITH SYNTHETIC GROUNDING CIRCUIT BREAKER WITH A PROVISION FOR PADLOCKING AT THE DRAW-OUT • ROOF EDGE FIBER ROPE PULL WIRE. AS xxxxxx N/A THE CONTRACTOR SHALL FURNISH AND INSTALL GROUNDING NECESSARY IN ® xx.xxxx N/A POSITION CAN BE CONSIDERED AN ISOLATION DEVICE FOR PURPOSES OF THIS / PATCH AND REPAIR ALL SURFACES DAMAGED BY TRENCHING TO MATCH THE ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. REQUIREMENT. A CUSTOMER - GENERATOR MAY ELECT TO PROVIDE THE EDC ACCESS / / CLEARANCES PREVIOUSLY EXISTING CONDITIONS. �5 xxxxxx N/A / TESTS 6 TO AN ISOLATION DEVICE THAT IS CONTAINED IN A BUILDING OR AREA THAT MAY xxxxxx N/A/ D BE UNOCCUPIED AND LOCKED, OR NOT OTHERWISE READILY ACCESSIBLE TO THE SETBACKS 15" WIDE OR LESS BUCKET TO BE USED FOR TRENCHING. FINAL TESTS AND INSPECTION SHALL BE HELD IN THE PRESENCE OF OWNER'S PAGE- EDC, BY INSTALLING A LOCKBOX FOR USE SOLELY BY THE EDC FOR OBTAINING REPRESENTATIVES AND TO THEIR SATISFACTION. 2 Or- " ALL PENETRATIIONS SHALL BE SEALED TO MAINTAIN THE EXISTING FIRE RATING. ACCESS TO THE ISOLATION DEVICE. THE CUSTOMER - GENERATOR SHALL INSTALL NORTH ARROW MEGGER ALL: STRING WIRING, COMBINER BOX OUTPUT FEEDERS, AND AC FEEDERS. NOTES ; GENERAL INI=O THE LOCKBOX IN A LOCATION THAT IS READILY ACCESSIBLE BY THE EDC AND ALL ROOFTOP CONDUITS SHALL BE MARKED PER LOCAL FIRE CODES. SUBMIT RESULTS TO OWNER FOR REVIEW. THE CUSTOMER - GENERATOR, AND SHALL PERMIT THE EDC TO AFFIX A PLACARD IN A LOCATION OF ITS CHDOSING THAT PROVIDES CLEAR INSTRUCTIONS TO EDC IV CURVE TRACES OF STRINGS SHALL BE GENERATED USING THE SOLMETRIC PV ANALYZER (OR EQUIVALENT DEVICE) AND SUBMITTED TO OWNER FOR APPROVAL I OPERATING PERSONNEL ON ACCESS TO THE ISOLATION DEVICE. THE CUSTOMERly - GENERATOR, AT ITS OPTION, MAY PROVIDE AND INSTALL THIS PLACARD. $ atio Solar as it should be SUNATION SOLAR SYSTEMS III REMINGTON BLVD. RONKONKOMA N.Y. 11' s ROOF AREA r (3)R«7F (2)ROOF 22 ROOF X p NYSERDA (44 MOD IS°TILT;4h2 PITGH (21°TRUE,18°TILL%4h2 PItGH �„ 221°TRUE;IH°TILT;4/12 PITCH j„ INSTALLER c44)MODULES Y_Y z O RIDGE (20)MODULES 1zoGE �� (36)MODULES RIDGE �� NUMBER 4 S, TY-e�' � Y Y-Ia' v 1PHOTovoLTaC STRUCTURAL CROSS SECTIONS FOR ROOF ARRAYS UC. F.E. STAMP SNAP'N'RACK SYSTEM VvV v ® ® MODULE (TYP.) E A P (TYPICAL RAIL ACROSS EACH ROW OF x(J ARRAY) s (ONLY TWO SHOWN FOR CLARITY) ° n ��OF NEW yo a RIDGE RIDGE 91 10.5" RIDGE 39-10" h�' T VVV vvvv1vvv MODULEfn4OTOOLTAIG��E _ 1„I�E PHOTOVOLTAIC MODULE 1 % f v v I - 10 vvv �•-10� ❑ " " RAFTER RAFTER i MD SPACING 2'X 12 /16 OG. 2"X I2"l Ib"O.G. O IN* ° °+'"�+ ,, (1W) EXISTNG INTERIOR (TTP.) V V DEARNG WALL RAIL EXISTING INTERIOR ^y DEARING WALL RAIL 0 VV'VV v VV II�v' ACTUAL SPAN ACTUAL SP UAL SPA I$-4" vv v v v le'-r' SOFRT 26-b" 29-4` 3Fi 10" sOFFrt 000v V" \7� EXTERIOR WALL EXTERIOR WALL - - ROOF SECTION(TYP.)-ROOF`I` ......... v v v v j y'NTERiEOW SPACING SCALE:N.T.S. ROOF SECTION(TYP.)- ROOF'2` SCALEN.T.S. v v v v V V v v v v v vvv vv VV v \ 4'-4' Si GUTTER e' GUTTER v v v v RIDGE N GurrER �� JOB NUMBER 2"X 12'/I b"O.G. eXI THG DEaRNGIL CUSTOMER INFO FIT SOUTHOLD TOWN ANIMAL SHELTER G)SMALL NE DOG PORT ROOF SECTION(TYP.)-ROOF"3` 41'TRUE;10°TILT;2112 PITCH SCALE:N.T.S. 165 PECONIC LANE (45)MODULES FENCE P05t PECONIG NY 11958 (TYP.) EI'-ay' JOB NOTES 1. NIA DOG PORT SOLAR ARRAY r (TYP.) 8' FENCE PERIMETER (TYP. ALL KENNELS) ,T,• 2V > DOCS KENNEL AREA PORT (TYP.) 4l'TRULAREO TILT; 2 PITCH (Be)MODULES all low w IY-4' Is > N (4)LARGE SW DOG PORT Id s'-s• 221°TRUE:10°TILT:2112 PITCH (2)SMALL SW DOG PORT (90)MODULES ANA 221°TRUE;Ie'TILT;2/12 PITCH (45)MODULES ADDITIONAL MATERIALS I. N/A �1"'1 Y " > I'll's > > > > > > > > > > > > > 1> .�> , DRAWN BY NENDZA DATE 12. 21 . 18 REVISION(S) DELTA DATE DESIGNER Al xxxxxx N/A 0 xxxxxx N/A XXXXXX N/A ® PARTIAL BUILDING AND DOG PORT SOLAR ARRAY PLAN XXXXXX N/A 0 XXXXXX N/A SCALE : 1/8 " - 1 ' © XXXXXX N/A PAGE= 3OF11 ' 40 25 50 FT ARRAY PLAN !/ 8 5 10 YD -V FACING STREET DRIVEWAY MationC Solar as it should be GROUND SUNATION SOLAR SYSTEMS GROUND AGGESs ACCESS 171 REMINGTON BLVD. RONKONKOMA N.Y. 11719 NYSERDA INSTALLER 4 3 55 NUMBER GROUND FOU DLIC. P.E. STAMP ACCESS CESS NE ty ro ) ROOF 1` , I I ACCESS �g fro- CGESS I I /� 07 ROOFI I ROOF -36"- ACCESS ACCESS GROUND GROUND -36"- I I -36"- ACCESS ACCESS GROUND GROUND ACCESS ACCESS I I I - I I I I ROOF ROOF _ _ _ _ _ _ _ _ ALTERNATE VENTILATION - 18" - ACCESS ACCESS ALTERNATE VENTILATION - 18" - I RIDGE " RIDGE JOB NUMBER ROOF ROOF - I I ACCESS IACCESS V V -------- 3 1 8 4 /� ro v vv EBNAT ENTILTION CUSTOMER INFO v v RIDGE I I SOUTHOLD TOWN ANIMAL SHELTER ALTERNATE VENTILATION - 18" - VVV 165 PECONIC LANE VPECONIC NY 11958 RIDGE--- V V v v v I ALTERNATE VENTILATION - 18" - RIDGE JOB NOTES vvvvv v\7 v /V 1. NIA V ,V ),V v v v1v V Vvv v v X_ V V11-1-- vvv vv/I vv I vv I vv v v vv'v v v vv vvvv v v v v'JI v V vvvvvv ADDITIONAL MATERIALS I. N/A I, \ GRO_UND ACCESS AREA - AN AREA ON THE GROUND RELATIVELY CLEAR OF OBSTRUCTIONS USED TO ESTABLISH GROUND LADDERS FOR GAINING ENTRY TO THE ACCESS ROOF OR R324.13 GROUND ACCESS AREAS - GROUND ACCESS AREAS SHALL BE LOCATED DIRECTLY BENEATH ACCESS ROOFS AND ROOF ACCESS POINTS. THE MINIMUM WIDTH DRAWN BY THE ROOF ACCESS POINT. OF THE GROUND ACCESS AREA SHALL BE THE FULL WIDTH OF THE ACCESS ROOF OR ROOF ACCESS POINT, MEASURED AT THE SAVE. THE MINIMUM DEPTH SHALL ALLOW NENDZA ROOF ACCESS POINT - THE BEGINNING OF THE ROOF ACCESS PATHWAY AT THE EAVE (GUTTER) FOR THE SAFE PLACEMENT OF GROUND LADDERS FOR GAINING ENTRY TO THE ACCESS ROOF DATE R324.1 ACCESS AND PATHWAYS — ROOF ACCESS, PATHWAYS AND SPACING REQUIREMENTS FOR SOLAR PHOTOVOLTAIC SYSTEMS SHALL BE PROVIDED IN ACCORDANCE WITH R324.14 SINGLE RIDGE ROOFS — PANELS, MODULES OR ARRAYS INSTALLED ON ROOFS WITH A SINGLE RIDGE SHALL BE LOCATED IN A MANNER THAT PROVIDES TWO 36 12- 21 . 15 SECTIONS R324.11 THROUGH R324.1.6 INCH WIDE (914MM) ACCESS PATHWAYS EXTENDING FROM THE ROOF ACCESS POINT TO THE RIDGE. ACCESS PATHWAYS ON OPPOSING ROOF SLOPES SHALL NOT BE EXCEPTION(S) LOCATED ALONG THE SAME PLANE AS THE TRUSS, RAFTER OR OTHER SUCH FRAMING SYSTEM THAT SUPPORTS THE PATHWAY. REVISION(S> 1. ROOF ACCESS, PATHWAYS AND SPACING REQUIREMENTS NEED NOT BE PROVIDED WHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED, OR WHERE DELTA DATE DESIGNER VERTICAL VENTILATION TECHNIQUES WILL NOT BE EMPLOYED 8324.1.1 ALLOWANCE FOR SMOKE VENTILATION OPERATIONS - PANELS AND MODULES SHALL NOT BE LOCATED LESS THAN IS INCHES (45'1 MM) FROM A RIDGE OR PEAK EXCEPTION(S) Ot xXxXxx N/A 8324.1.1 SIZE OF SOLAR PHOTOVOLTAIC ARRAY - EACH PHOTOVOLTAIC ARRAY SHALL NOT EXCEED 150 FEET (45,'120MM) IN ANY DIRECTION. I. UIHERE AN ALTERNATIVE VENTILATION METHOD HAS BEEN PROVIDED OR WHERE VERTICAL VENTILATION METHODS WILL NOT BE EMPLOYED BETWEEN THE UPPER 0 XXXXXX N/A R324.12 ROOF ACCESS POINTS - ROOF ACCESS POINTS SHALL BE LOCATED: t"IOST PORTION OF THE SOLAR PHOTOVOLTAIC SYSTEM AND THE ROOF RIDGE OR PEAK. 2. DETACHED GARAGES OR ACCESSORY STRUCTURES. 0 XXXXXX N/A 1.IN AREAS THAT ESTABLISH ACCESS PATHWAYS WHICH ARE INDEPENDENT OF EACH OTHER AND AS REMOTE FROM EACH OTHER AS PRACTICABLE SO AS TO PROVIDE ® XXXXXX NIA ESCAPE ROUTES FROM ALL POINTS ALONG THE ROOF. 2. IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS OR AREAS THAT MAY CAUSE CONGESTION OR 0 XXXXXX N/A CREATE OTHER HAZARDS. 3. AT STRONG POINTS OF IBUILDING CONSTRUCTION SUCH AS CORNERS, PILASTERS, HIPS, VALLEYS AND OTHER AREAS CAPABLE OF SUPPORT THE LIVE LOAD FROM © XXXXXX N/A EMERGENCY RESPONDERS. PAGE 4. WHERE THE ROOF ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS 5. WHERE THE ROOF ACCESS POINT DOES NOT CONFLICT WITH GROUND OBSTRUCTIONS SUCH AS DECKS, FENCES OR LANDSCAPING 4 Or- 11 6. .IN AREAS THAT MINIMIZE ROOF TRIPPING HAZARDS SUCH AS VENTS, SKYLIGHTS, SATELLITE DISHES, ANTENNA OR CONDUIT RUNS. ROOF ACCESS PLAN ROOF ACCESS PLAN WALK - WAYS AND SMOKE VENTILATION SCALE : 3/16 " = 1 ' x5UHation Solar as it should be SUNATION SOLAR SYSTEMS III REMINGTON BLVD. RONKONKOMA N.Y. 11119 MECHANICALLY ATTACHED N1rSERDA INVERTER LOCATIONS SMA STP CORE 1 33-US (X4) INSTALLERNUM 4355 33 . 3KW AC MAX APPARENT POWER SER 277/48OV, 40A MAX OUTPUT UC. P.E. STAMP SMART INVERTER SYNC FUNCITON (TYP. ) oF I~1`H,ro � PV PANEL-BOARD 225A MLO 480Y/277V ' . .� 3(p / 4W NEMA-3R 150 KVA PAD MOUNT XFMR 208Y/120V WYE PRIMARY Oo 480Y/277V WYE SECONDAY DP-1 NEMA-3R EXISTING DISTRIBUTION PANELS DC TRENCH / s DP-2 WITH SERVICE DISCONNECTS (GRASS/DIRT) 1-Q # (2) x 200A 400A SERVICE S 3(p, 120/208 WE X45 NUMBER / 184ro& Q_ CUSTOMER INFO / O SOUTHOLD TOWN ANIMAL SHELTER 165 PECONIC LANE PECONIC NY II958 JOB NOTES \\ Y< 1. N/A s� 450A FUSED SERVICE RATED/UTILITY �O DISCONNECT SWITCH o 3P 3(p 208Y/120V NEMA 3R �\ O y i� RAPID SHUTDOWN ACTIVATES HERE EXISTING PSEG-LI �,� ` 150 KVA PAD XFMR ADDITIONAL MATERIALS 13 . 2Kv PRIMARY �G 208Y/120V SECONDARY EXISTING PSEG-LI 1. N/A ti � REVENUE METER 400A TRANS-S #99823750 o 4W-208Y/120V PSEG-LI RISER FEEDER 8B952 INTERCONNECTION POINT DRAWN BY NENDZA -let AC TRENCH DATE O (NON-TRAFFIC RATED ASPHALT & GRASS/DIRT) 2. 21 , 18 NOTE : REVISION(S> ASPHALT TO BE RESTORED TO ORIGINAL DELTA DATE DESIGNER CONDITION IN KENNEL AREA Al XXXXXX N/A XXXXXX N/A 0 XXXXXX NIA A XXXXXX N/A 0 XXXXXX NIA SITE PLAN EQUIPMENT LOCATIONS ® XXXXXX N/Q PAGE: SCALE : 1/8 " = 1 ' 5 OF 11 EQUIPMENT LOCATIONS Ea DOG PORT ERECTION SUNation Solar as it should be SUNATION SOLAR SYSTEMS Ill REMINGTON BLVD. STEP 1 STEP 2 STEP 3 FULL RANGE OF MOTION ALL ASSEM STEPS LEFT AND RIGHT SECTION RONKONKOMA N.Y. 11119 INSTALLER 3 NUMB R E LIC. P.E. STAMP 77 7U ---------- ---- -- —� F Ntzw ro i crra�� o DOG PORT STRUCTURE JOB NUMBER 'a• --Isa 1 8 CUSTOMER INFO SOUTHOLD TOWN ANIMAL SHELTER 165 PECONIC LANE PECONIC NY IIS55 IJ J J JOB NOTES 1. NIA INHABIT UCKING j L 1 1F11 FOUNDATION (nP' ) J 11 DOG PORT PROFILE ADDITIONAL MATERIALS I. NIA 1 1 1 1 rr DRAWN BY f— NENDZA w DATE ENE 10, 12. 21 . 18 REVISION(S> DELTA DATE DESIGNER Al XX.XX.XX NIA OZ xX xXXX N/A J XX.XX.XX NIA ® XX.XX.XX NIA I 1 1 1 I 1 I I 1 1 I I I I /5\ XX.XX.XX NIA © �XXXXXX N/A 7 I 1 I I 1 1 1 1 i I I I I ' PAGE: 1 1 I 1 1 1 1 I 1 1 i 1 I I PATHWAY BETWEEN KENNELS SOLAR PANELS AND RAILS ro O BY SOLAR GC 1 1 I 1 ( I I I 1 I 1 1 I I DOCS PORT PLAN a INHABIT SOLAR CARPORT STRUL-- ---------------------- ---------------- ---------- ---------------- ---------------------L-------------------- CTURE II ' •a The primary objective of Ull atiCJ article 690 . 12 are to shut ® ® -Al Solar as it should be — — _ VVVVVSUNATION SOLAR SYSTEMS down the photovoltaic r -78) - ca) FROM III REMINGTON BLVD. t-DS 1-Dl ROOF ° — — — RONKONKOMA N.Y. 11'179 system conductors within vvvvvvV V ® ® NYSERDA LVVV VTo 10 seconds in order to — — (8) _ () -- — .�8) — — - c8) ROOF O ,� INSTALLER 43E6 I-F12 1-t=11 I-F11 1-DS ° ❑ — + (9) NUMBER - (9) 1-A2 UG. P.E. STAMP protect first responders — P .reg. (8) - {3) ,-At ;� :..,�. from elements of a PV — 78) VY V V, 1N=„ 1-D7 ,� 6 X system that remain - -° � C9' � (g' Y ° 1-83 1-A2 I I - 1 7____1VVVV_"__7 V V VVVpF NEW Jr 1 energized after the AC — —V- (8) + <8> VY ""� �8) "°� — - (a) O 1-F12 t-E16 I-E1 1-E9V ..ww® -� ..... — �• .R - . .�...� ....� V I V service has been shut off . 000 _ + I B3 1 B4 1-84viv e r � INVERTER #1 + 690 . 12 Rapid Shutdown of LOCATION 1-G WITHIN 10' OF ARRAYS j PV Systems on Buildings . (MECHANICALLY FASTENED TO EXTERIOR WALL OF ROOF #2) + w - (a) 1-Gly 1I-G5 PV system ci rcu its INVERTER #2 installed on or in LOCATION (MECHANICALLY FASTENED TO DOG PORT STRUCTURE) JOB NUMBER buildings shalt include a + cg) — V_' (9) 2-A1 I- 1 4 rapid shutdown function ) that controls specific 2-A2 -A2 CUSTOMER INFO SOUTHOLD TOWN ANIMAL SHELTER conductors in accordance 2-83 ' + (g) — (9) 165 PECONIC LANE r ni ease a seews mase. a "' wewa eemu 7. .ameeenr ew•se .ee 'd.,•. with 690 . 12 ( l) through 2-B4 ,' ' 2-84 PECONIC NY 11958 (9) . a i ■sin JOB NOTES(9) (5) as follows . 2-G5 2-G5 I. N/A 1 . Requirements for 3- Al ✓ 3-Al 3-D6 a 3-D6 (9) _ controlled conductors — - cg) 3-A2 3-A2 3-D7 ,. - 3-Dl shalt apply only to PV + <�) a.nw.. _ w _ .aw.� .,. ,. - �. (g) + (g) 3-83 3-83 3-ES 3-ES system conductors of (9) 3-84 3-84 3-E9 more than 1 . 5 m (5 ft ) INVERTER #3 - - _ + C9) - C9) + C9) . (9) LOCATION 3-cs '� 3-Ga 3-Eta 3-El a in length inside a (MECHANICALLY FASTENED TO DOG PORT STRUCTURE) building , or more than 3 m ( 10 ft ) from a PV a r ray . 2-D6 „ 2-D6 4-Al - . (9) + C9) C9) 4-A1 4-D6 4-Do Ice) 2 . Controlled conductors +_ — c9) c9) A2 + _ 4-A2 4-D1 ' 4-D7 shall be limited t o not 2-E8 ;� ' 2-ES 4-83 - --- - - . -�° - �- — - -_ 4-83 ✓ 4-E8 -- --s — C9) — more than 30 volts and 2-E9 2-E9 4-54s . .. > 4-84 4-E9 r 4-E9 + (9) - (g) + _ ADDITIONAL MATERIALS 240 volt -amperes within 2-Ela — `g' �— e. _ +_ I. N IA — _� _ INVERTER #4 :b 4 G5 4 E10 'T{ 2-Ela ' 4-Gb rw . ;,�- 4-E10 LOCATION 10 seconds of rapid (MECHANICALLY FASTENED TO DOG PORT STRUCTURE) shutdown initiation . 3 . Voltage and power shall be measured between any DRAWN BY two conductors and STRING CHART STRING CHART NENDZA between any conductor TYPICAL FOR INVERTER #1 TYPICAL FOR INVERTERS #2-#4 DATE and ground . STRING # MODULE QTY. MPPT INPUT STRING # MODULE QTY. MPPT INPUT 12- 21 . 15 4 . The rapid shutdown 1 9 a 1 9 A REVISIONS} DELTA DATE DESIGNER initiation methods 2 9 A 2 9 A � XX.XX.XX NIA 3 9 B 3 9 B DC WPLAN & RA STRING KEY shall be labeled in PID SHUTDOWN 02 xX.xxxx N/A . � 3 accordance with 4 9 B 4 9 B SCALE : 1/ 8i = 1 ' POLARITY STRING xxxxxx N/A 690 . 56 ( B) . 5 8 C 5 9 C 'LENGTH ® XXXXXX N/A 6 8 C 6 9 D + � 0 XX.XX.XX N/A 5 . Equipment that performs 7 8 D 7 9 D © xxxx.xx N/A the rapid shutdown INVERTER- STRING� u.. �. 8 8 D 8 9 E NUMBER NUMBER PAGE .shall be listed and 9 8 E 9 9 INVERTER♦ -1 OF 11 E INPUT .identified . 10 8 E 10 9 F DG WIRING PLAN 11 8 F 12 8 F 11 - I I"� , � a10 � � Solar as it should be SUNATION SOLAR SYSTEMS 171 REMINGTON BLVD. RONKONKOMA N.Y. 11'119 /, * ,ntss•,: tk ;m:x aL.. ,i'T*�r�!•s;; `,. » F'/�13�!T'- �, b 1%/- - - Rm 'nc. 4�*.....-r•.... ,.,.y^C _ _ NYSERDA I. _' �,4j. , "'�L^'; 'ire, .B"�'r- +at,w. ,1 'd -'�,f' +.. $' 'y,° _d xF a: r.:t,- �. • _ �5'r. oaf •f I I - - 7- ,``+•* a 1., y _ ,, i', I �I ...• �." 'S NSTALLER _ K "° �. ' ,_ . � . <n t ":� i ��,".` *, . T'4 '.. gyp, •_+ L: ___�_ .:!Q'^ ems, P >'v a°.'•"+.R,e•a•".• ;p,'":';,>' .,:rr:y'« 7s+,. _ �.','� -�_`a0 i`�'^r '`s.. ', 43�� S _ "'' .'19�'.i. - _..,.,aw °^"�' :..la4.ior �*• .c�,.. �^ i, ,,1Ae.'x ': 'r:: `}�� .tag' �' �, .. .: , ;: = j ,., ,.< _19 NUMBER I #°, ,. :,,,& " -•ar,..ew� "�' _ ,_ .„ ._ „^rv� �•�'w°"M,'`;.� M e-.t .>^.».' _ ""ti*s's,�,p.' ;"�'; .`§i '.r, c r' E•"��� _�L ' 1r". t- W. }� i ;.: .v}."T°,,N+i _ r,<•n,'s`o>~"''a"..,,..v+s+"",n`..s,•..- - .. -•'b`w .:.+r„t°,>t, .,. ~yy: !.. = •*a }rt " %' , � e `.• \.:'.v`:' :>::' �.v` . 1-m T :.r �+•' `,�'' '.+ P+a,.. _ -_ ,a,... 4 e ti '"° "' i '*a. ':1�q., .,+.e' ;arf .':�... \�;s P. �tK"'$""., � -_ ',°Y r�'gk';u.•r+'':1,"' .`�" ':.n. < ,'!� '` ', �' •; ';�;,r - ;r" �r ';\- '� "7: _ " '. / �. .r .,. .� .. UC- P.E. STAMP �:. ."`, w . :' <" .. � _ ) f *• , IN F ip --- ,y_�; .% ". :,.' _._- - - _ - "- -- i1� •�- - a.... .- "I,�%�� '+°'•.w; a -•�',9p„T.-, rr- (//.y «J 9 \ / „w«..V77777���� .w".'^++w'mts.Y,p*�..,_ .. \, , � - ... �L `<,..b-'. t. " - -- - -' �1r_._)" i aw'Yy - - � -' �tif'k -�.- './-16"., il�'�"''A :�f -IN PR' -.-. _ _ _ _ ' 1 - r ° 'rtfI �aA, �r 1 Y P 1♦ \ r 4„ \ ."'. '.' AA•f1,IR - _ -- -- 'l kN'i :.tr.. T yp'°4 .vF+ J'. �_ l � �J r.<,y,,,,, ✓r p - - o -__ a *� d, - - - xg '� ;� I - - 'y _.-._ I � _..._ ," ^� - f,_ f r r1 rF -i r F ." 1 t11 p - - � I �_ '-_ ' " ry - — — 6 .11't I 11. I _.. '_ I F7-- , �� I � ' A � I - F- 7' ',i!;r '_- � I -- I I 1 - . . .� �� 4'� f - F 3 u _ 'a 11 l I i c f - 1 ea °� ' f e w i -� }/ f t•t r 'ti e t r r � 44« w` 1 - -4�'` .c ! as' 3 — `� -- - i l »� r- � ,rQr a I µ � q 4 Id r - �y r v Jp �p >n t _ r 1 (/ �4 f r •� f _ - { s r f _ �t t 4 P f _ 4 d F , , . e rt rc, `n"'t r, r .',_ ' _ d' i" T4! ,. I l , + , . -t .i �T' f i ` / .. � .`"a J I ! / it � �y��J , '-" - - -r f ! r r l �,."'_ t'y.t r , ,xr• P' "' •'' + &3'" • ", 'yy\' ,," 'a, L/� e„y"","1"'"eX'' - ^ - - 1 ""t 1 `� - ., - -�_I- - t -'--.1--:,_ - �"-_ '- _ - "� w ry'' '1.:f .r.' /.fi- + `F' .• - <,w" ia: $ .. ". ,. , ` � .. -+ 1 -i ° 1 a 1 i i t _-- 'y ,-r ""aw.•'..=aC-.x:>... _ - _ ,r �1' `�' -J"'rJ1•'�',s r':1r °�"<S f' ." .4 rt1� l ,.t. _ �'..J 'I - -. t I' r - `' i ^--•'( 4i ; F-----', `t �'"`.-- -' '-' - +'" - _ '$' ::, ,o' ,'9^ '';,.''`'� - a ,-•" "''•, 1. 1 . t 4, 4 ` - - 1 •,,e', a 1 r __/ .'"�1I1/�.�'If t I ["-F'_'_, fir--. - _..-._ _ '?" 'e,-�' ,r," w, tf.It ,j J, N� '�'' t, f '`�+y 'k"" '� �> ' g �" , +I ,"�F' '' -'7 } 1 _ tr,. __' .m: g� ,'4 ,r,y }/1 {�yg r(>�T*j•�� ,/+^'�j . 3 `.,�. t=4 x11 r +4 -• a a _- ? --q„"�w ,:¢,, r t� // p .�< g_ .* my_�"3+ t *� '.g° "s,,,,, x -d - y >. _ . , a' }r.,1"- jT .°, m ,,i 'f `410 ,('d •;' t" t I a4 �,, "..y '� ;,"Y".•.a i.? „i ,:.•��t J._` "( - a - I '^—.,..".-- �'«#'a'` ••T ,a ,, ^w:, ^,F. `� I �`m ' 's:p g�„�' ;\, '"�'y`• ,. a h� ' 11 'r-,-I s t s j � ip ' - - '), .1 � , - �' �� I ", I ,� '. � lz'," I \ g"" Yn -. '._ (r "`1 Yf. °F.. '` 'a+ t4>.�R ..2�"' `r , p `g dr I R �" ,.n ♦.." n I S �%`_S `„ j. - -M'' '° - � -- �;,". :',I�F;, ai>:, r •a` `�' ,'r .,` at >'.r ,, d ,p. - � 4zI. -,..... m ' ,, - ;.rwwn.:� �*n��!; ¢. jj¢'y1 _.J-,_, -/. +'~�.(F 1a..a`y.^'F��`¢�ia.G- I s„J N£ ,' ". •.' . f : ... "».. .. "- »..-'n tiy.1 '�" f' :. - �r r,.lr - y 'ry 'y� •S, «ya 4 -1,- - , ++-„'^."++n a ..2 w- ,..dF'.na2 w4...,..-e,.. 5 „. - : - , I / w�.P- s,,R'�'Y,a ...' "�Y' .d'.,.vv�� Fy J e 1 r�',” _1 ' r 4 /' , �£r :° ` . 4p h ff�� l"^'.n,. �, ` •! 7 a �I ,7° ."`1, ,�`�,nD d a $f ,. $ ))/ "f" '��//��a A ' ; L {, - f,+.,..... _ _ - "g•=.r"..w.4 "' $ ,yNey :vp ,d' e„�,>< "�b «i+ L,, '� r4� ; ,•,,, 'R 1 1 a'•, "'� 1y',r' .. ' ».«..*.....e.-w,,,.: ,:. i -1 '3 ._ - --� ,< 'se,.t _ "www,,-„ 'r "` � h'{gX„-,/f;.r*' l °- y � ..1: �,� " R .T' 'ieg.� . ' 7 - - 181:2 �' { %^, _. 4<r e• K ,� N `� y,q°'f,r':ll, 11 r• f '�� I`x t'Y .°,1 .. `^'/r d �,..,. . kk �: - " t ,:,, ,. . ' . y . �,,• '. /`I 'fit. JOB NUMBER F _ 'w L.. k' s -- jti .` A. i ''9, ,• •r.+�`<,;<".°r•:<�"`••::.y'e . '"Sq°b, �'. f• i� r• ''ti t q,, .. • p _ .,^. Y: .'v+"«^^"'s, rl.., - ill . , `b -�r'' f' t' k ],,..Y r�1 �.G i • f y F'- i .11 T-W . ' . I r, ' , A , -'"'"'+ / , / , i '. t "T,,°," 5 •i . `.,161� 'Lr' v1 Y'' y f -lank" -' ,✓1, `' .1 : 1 j! " ,/� / /. / r t \ / °', P ,,ar.,. }qtr r "��,'`.t'(} /, �$r �;,.. .- x f •� 'r"?` a` 4 .'!-__}. / i t � .gym`. ."• ; :." .. ".: a , ./ ,� a -, I CUSTOMER INFO F - P _ - /,, I , ,� $ ",+' s��'°�', ' ",.}"'°'';y+' '•:�sY#""M f:`.;' ',,,,-.' A.4:r ,. a�1°�°; i' e>7' �, 'an' � `��: .( V ..r ? e, ' / � _ � , ,F',.,k'�' �+'' '`r. ", 'jr ,"' y,• �Gj'. �'- " r >" 'e' ,ry o.,�'"` fir• '., - ,y`�•, .. .F - / I 1 l ' '°,Y.t, Y' b .8 ,.. ,sl°. ° { 'b° 0.�! -9 L' -.'L.,. +' `s„ W ^- - - % / i ` s \ \ ,i' .•' 'w1 '., r MF''r - p »f aH'`t1k '`+ "•' ;,,w*r`$"` ,�,';�,.. '' '`* I�w,,,., `d ,� I t SOUTHOLD TOWN ANIMAL SHELTER / /' ` \ ,F��ii 'F..//g '/u: '«i.4' i p' -s , � i `e. ,. f 1 i — e .e•.'J^"_- r// / i - .r l- , ,', - ,\ .�. I•../ c.,y r� Y� .,3n, fd*'- ��.., ,.'1P .«>v <t 'C 'nY„e`°Z r. `4 ]] If ' 11 I / /1.Ir i { ,. \ *' ';; �”'# * ;"'•`".,•�r "'4'v` I...:�=' � ` a f ° 1. >,,;, 165 PEGONIC LANE .i \ � p:' :-�,,r "' `Yw'',"t:,"}. , ;',- f ECONIC NY 11955 �` ;," -. ry,- �: " .LNe, s i �,' \ .\ ...s.:.#"'.w. :..,c. ,_.:. !,i_.rw. ... ..,...-. ..,nd..°.. . .. ... --.;"I-.s�.�a`.a.SG....-.,..".,,.r,,- -....-°r,..a<.,-„-.x..,.s.a_ .-_�,•._,-.� ..r_.. ...-.�.�.,.t. `l."''le.....<... JOB NOTES I. N/A 11 11 A""N"AYLOCATIONSff��o m A A - 1= IMA...."m ' ' "as V�% 0, �m r mg? Vze I -% VIA %=01C, OUND VIA ”' OOF -��".''_'.' ,,, M nu,- .'.11 ee' "'' _ 'j"r 11 � IL 11, I . '� t I/'. / 1 14 1p�'L`:-4,�'�,W"_ ., I I - '-��'. .. A r I � -1 i I . . . 11 � "X 1< % ']i �� . I ' ll � '.'� , -1� , � I ;' � . . ' 4z.'v �� , . - ", ' '", '11 o� i�' AX r.4,I I t - - � - ` -- ��,1 LONG ISLAND POWER AUTHORITY 1 ' .__„ .. 1 1!.811 ,e "' i �� wr fI-f q3.,911 . .110//.. ` ww "° 99823760 _^, 9�� : 91 i,l 11!r Hl i9t'p o 9 '. „yY ._ , ,ple ` ±'>a <r�,$ 5;' m.-s ' s r .ii,«t+,,*'":,?lF,,,SAMr"�",.,lP`v"•t"`"'W,- 'na»,.,'� „"..,..«,~,:,...<,.._ ..:"4:-,:,; 4 J t <l' 'mow.... i , - . „u m.,,,,.-w_. -, , as '".�,b""'.',;, 3 ' i- R r =m , -e " `- ' 1 ". r`�V .,_ i,F . IL'' .. - k •...,..rq, ,u-ne .. ;a �.0 Y �: .� w e ADDITIONAL MATERIALS rT>r' 1. N/A u� 4 w CC . - I �I , I , L t'- "0 I "t :,." ; . w r -a..:� ' I`.� " ffi yn,,& L-- " ., -w .r- I .1 "">i• a �`Y`•.>- L. '11 - s .< i.-_ - ,., �.<.,.,_.�,-. - .� r_- 'it' , ,.,. .. -._. .,-,. ,. , % li, I 11 •• - / .! FF - _ .-.., Lk ,i" .,.. ...»._ '! ,-fin °1_ i _ �,.- q ..._ -__.._ 6 -i i' ' � ' S �_ ", ,.. ,eree+ar. «gt ' } '" - " t "„'"".^”' {£j� r, .. '/, ,%•' iii ///i!/ , a ' [!" "_w....„-.: w.k.. '""_ •. ., - - .._ ^ v _".M. _ , 1, t a .".. '.. ; 1 .. `: = °. E DRAWN BY / / / - % / .w j' /�! / f / /; i�'/'' i ; �,, __, x -.ft.'"� .. "_ "' ' __ NENDZA 1 f ' I I / %� L / / 1, r ( ` / - / . ` \ \\ � . . 9 1 ..,,..,...,». p `9+ { £„ '!TM,' _I _ -1 /,r / r / r '( y `t '\ .,+• _. - p d- , r �,,, .- ) ^ # s 2 i k ., -.., - DATE "/" / / . L , f4 - ,_/ /! i �., . �'-_.." 4 =�.j � I I � �, . - , ; . __J_ I . r 0 � 1. ,�� 12- 21 . 15 ro�' / I �� , ,0 / . i ; L t ��' �. " 1 I-- _' . _ � . 11 , : . --- I I I I I -— " I - � I � 1 ,1 I-.' I I ,� { ' , " ' r I ' ,I !; REVISION(S) b` .� k, F I i w N li DELTA DATE DESIGNER I ,; a -, -, - I `� ¢' 1, 0 XX XX XX NIA , n f � -I � � - 2 XxxX.XX ^ _ F 0 NIA 11 - . ; + . , I �. I � , ` 3 XX XX XX ,- 'i ..a \� �.`.. .. . ., t� 1 NIA � , L I �� L_' - _ ' ,,, — .. k t 4 ® XX-XX-XX NIA . .._. .r<, 1-1 I i 0 XX-XX-XX NIA L, 'I ` ` 41 i � © XX-XX-XX NIA i , aN PAGE: r t__"Wo c!"o. SOUTH VIIEW "On"' O 0SE'"' EXISTING 9 O 11 SITE PHOTOS VIA . 0 .1, -., . �77 777 w.r .+J "�'_ - - �-...iW"^-...i,•..�W^" -_./,-��./' R . "`" .. " d•` _ Y''41Yrv¢ .._. � - '-.i+h•w'/.rt" - �,ffi- _ .�,�•` ,.,,n _^'-_'.w<" •...-a-- ..�- --- a .....,,�_„ - ..,_,/'�,YC _ - .d` .«....«,..' ,"---"`.M...,-i.sem *'a" - "-"".^.A-"°`.-.r,.,-.+-,..-- ^'1✓-/_._,.,•_,i�`� `5�` .a _». �' t �Pwat I O S rack Solar as it should be nap r s ---___...._..._.�..�......... , Y ,:...� •�.y -arn�+m.+M•s„ .a,k,�,"'n f � /" -` "• . �• :'�"'."..'.=,�`il,'._�_ dr...�.. w.. w -' - ,,,,_,/ .� s� f.'f . . ,_,_`^„(`yI4' ...-._._...�_ ..... - .. ..,... , ` "":-�-•_ .,�.��.-�.'' ,� ..Ty.�.,�,.�,w�.... •�„^„.-��,;.,.,,��-.- gid,,,._ :. � ' ,..� -•-.._ Solar Mounting Solutions SUNATION SOLAR SYSTEMS 1 11-ZJ �' .. h> i , . :, -,__,,r J' ° Yd...; l' ► �tl REMINGTON BLvD. e; e,: /' 1- y.' -� �y `. ' .� -•` ,'° RONKONKOMA N.Y. ni79 .a "" - 7 s+•"`�� -- - sl ,.t, - '- Stainless Bolt with Stainless Steel `, '- t Split-Lock Washer Bolt with Split- �, :! Boinsert015-09816 Splice Standard it ""- "..• - " ti- y�+ e Lock Washer Bonding Adjustable Asn .L=: + ,#r .k r- ,� a -�' .y" .;�; y y•& A. _ _ I End Clamp Top Bonding 'p4yg,r a t1' 'f�t Clot e°" )s�P'Ir .,wa3y°•a f1,• nr° '_a�. ,�•sl t• - J` � d@ t "- � , ` plice I N1SERDA _ .... .._-u.�,.._... --- .._.,..-...,_..k...�_..`.__. ............ . .... _.__.,.._...-_....- .._... ,.. - ....,..,«."..,,..._-.....- _ . ....--.. ..._..._._-...,_.. -.._-'.- ._ -__. -_,._. - ....-...,..�.« ...,..........._•..... ._,..u-.... _....�,ww..._..,..-.. ----- - �......,.___ -......_ .-•... ,.. .. -- -Mid Clamp vVr , Base r� oBon in NS4355 TALLERBonding Adjustable Bonding Channel Nut End Clamp Bottom Channel Nut Stainless Stainless Hardware with Bolt with NUMBER Split-Lock Washers Split Lock More than 21% Efficient High Performance & Excellent Reliability Banding Adjustable R End Clamp Bonding Mid Clamp BondingW Washers Washer P g g SPR X21 4 vzos3 Rail Splice Ground Lug LIC. F.E. STAMP - _ ----- zil Splice 242-02101 12-6 AWG Captures more sunlight and generates more (- 70-COM SPRA21-460-COM SPR-X20-445-COM UL1703(Type 2 Fire Rating),IEC 61215, A�..` ^,.� � Standard Ta5C57 yp g), zaro2� r. ..___ z4z..- ...,.,.., -._ _ .. Copper Wire power than conventional panels. .;� ....-.1 Nominal Power(Pnom)'� 470 W 260 W 445 W IEC 61730 "` may,.., _ Ground Lug Assembly Power Tolerance +5/-0% +5/-09'0 +5/-0°0 Mana;ementSystem (ONE REQUIRED PER ROW OF SERIES - -- ISO 9001:2015,ISO 14001:2015 MODULES) Maximum Performance Avg.PanelEfficiency5 21.7% 21.3% 20.64', Certs f r` r �f. 4 fi .r, "_` Rated Voltage(Vm ) 77.6 V 77.3 V 76.5 V ROHS,OHSAS 18001:2007,lead free, NE PP EHS Comp iance -• ,. '� rO Delivers excellent performance In real-world a,n >.. - pp REACH SVHC-163,PVCycle 1 Rated Current(Im ) 6.06 A 5.95 A 5.82 A t'i' Cradle to Cradle Certif ed'�'Silver f- ) . Universal End Clamp(UEC) y !!!! conditions,such as high temperatures,clouds - j open-circuit voltage(Voc) 91.5 V 90.5 V 90.0 v Sustainability _ Wave I - (contributes to LE ED categories)`' ;. UEC Pull Strapand low light.' n ,r 9Short-Circuit Current(Isc) 6.45 A 6.39 A 6.24 A Ammonia Test IEC 62716F<7_� - `' I Max.System Voltage 1000 V UL&1000 V IEC - ' 1 Desert Test 10.1109/PVSC2013.6744437 UtilityGrade .I Maximum Series 15A g t, 1 I ----- Salt Spray Test IEC 61701 (maximum Severn ) - , UECWed a Stainless SteelBolt Pov,,er Temp Coef. -0.29^,0/°C with Flat washer �.,. �- .._,.,�a.._. �._. O timized to maximize returns,the X-Series i � FID Test 1000V:IFC6280-=,PVFL 600hr dura*ion � ' • � P _.r Voltage Temp Coe.. -223.2 mV/°C �' �����.�- universal End Clamp Available List,--s UL,TUV,CEC 242-02215 panel is a bankable solution for large-scale Current Temp Coef. 2.9 mA/0 C standoff --Clamp �^+� SPR-X21-470-COM power plants. Assembly '~ 44 l,. 1 Sun Power Jvl Will-, a HighEfficiency 15unPower3E0'::'compa,ed;oaCcnventicnalPanelonsame s,zedarray5(260V1,1f^: Generate more energy per square foot Temperature -40°F to+185°F(-40°C to+85'C) effio-nt,anprcx 1.6 m2),4^h more enermi par wa^(,v! -d on 3p'y mod>1la Rubber Serrated Stainless o -Channel Channel Nut cha,acc'iZaton and P`✓S m),0 75°bryr slower der,,acatior,(Currpe_u,Z e;al."SunPower Rain Collar Steel Flange Nut /"' Nut Impact Resistance 1 inch -.) Stainless More energy to power your operations.X Series commercial systems convert P (25 mm)diam,.ter hail at 52 mph(23 m/s) nnoc_ De vadat on rats'_unPo:!'er v h to paper,2013). Serrated Stainless Flange Nut Appearance Class B 2"Suri�ocwer n'odde d0 Year Usef.,'Life"SunPav+e,whte paper,May 2015.Useful'life,s Steel Flange Bolt ' 92 Degree -Stainless more sunlight to electricity by producing 45%more energy in the first year.This PP Mill Finish ' 3 out of 00 pane's operatingat mo,e than 7015 of ratad pc a Standoff L Foot rd_ Flange 0 Solar Ceps 128 Monoc stalline Maxeon Gen III �•T Bolt advantage increases over time,producing 60�omoreenergyoverthefirst25 3x-series San'ea::Eser_'S,Sor:���8parelman�ra�t�.,rerste;te�,n2olsre���rt,3 ,.,, a additional panels m 201^ Ferrara C,e-al.°Ffolinl'c'-'r P`✓D.;rab'y Inst ative fn-Sola, years t0 meet your needs.' Tempered Glass High transmission tempered anti reflective All Purpose ' rt2".Photov°Ita"cslr•crnariona1.201c J �' rq' junction Box IP-65,1230 mm cables/MC4 compatible s Stanlda5d rna ar cnm.!horn�n°wJ m rm war a A/tr 25re derails. p' 7 L Foot r s tem warranty/for m^ �.1 60�0 /` Mill Finish .r We' ht 56 Ibis 25.4k est conditions(10,.D 1.5,25'Q. Standoff " St d:d:506 S currant,LACCS F=and VoIL3Fa ti xt L Foot Base Assembly Maxeon Solar Cells:Fundamentally better Base 0 Hole Mill Finish Metal Roof V nil:50 psf,2400 Pa front&back Base Shown) M Flashing Engineered_ p_ desil,ned for reliablity. _, Max.Load 6 3asec on a\-e•age of mP=;ire..^,pov,arvalues during prediction. _ L Foot Base Snow:112 psf,5400 Pa front 7 T;,pa 2 fire rating per UL1703 2013,Class C ire rating nor Uf_".703 2002. s ,.:•u,J ;.';..'" Frame Class 2 silver anodized;stacking pins Standoff _ nr�In�pre or Pr ormar�e, Metal Roof Base L Foot Base with Flashing with L Foot 11 av see Sa e_ erSDn for d :ails. 242-02037 JOB NUMBER Engineered for Peace of Mind = 1�,k _ q j,, 2292°5>' 2'2-92°5° Designed to deliver consistent,trouble-free u 184roro energy over a very long lifetime.' Designed for Reliability • 6000 Series aluminum CUSTOMER INFO Best Reliability, Best Warranty 46 mm The SunPower Maxeon solar cell is the only cell [1.$in] Materials • Stainless steel SOUTHOLD TOWN ANIMAL SHELTER A better warranty starts with a better product. Proven performance backs up 2067 mm �, built on a solid metal foundation.Virtually ry g b p y �- [81.4 in] . (� • Galvanized steel and aluminum flashing our indust best coverage,including out warranted 0.25%per year 165 PECONIC LANE impervious to the corrosion and cracking that � degradation rate.4 • Silver and black anodized aluminum degrade conventional panels. FRAME PROFILE PECONIC NY 11958 1046 mm • Mill finish on select products Power warranty Product w,;rran'y [41.2 in]I , p Same excellent durability as E-Series panels. ,.., I I � E� � Material Finish f 3 Silver or black coated hardware fit Rankin Fraunho,er durability test. I I �A) `" JOB NOTES 1 Appearance of mill finish products may vary and change over time. I. NIA aza,mfta.n torn,sine Note: 22 mm[°.9 in)SHORTSIDE °-^ (A)Cable Length:1230 mm f/-10 mm 4 X 398 mm Wind Loads 110 - 190 mph - (B)Stacking Pins [15.6$in](B) p (ASCE 7-10) Snow Loads 0 - 120 sf Vote guaranteed power.9$�for fi'r,t year, CombHeil Fewer arc.Product defect p -0.25%/yr+to yea,25 25-yaar co':era e Please read the safetv and inste"anon Guide. Document#524035 Rev B/LTR US Array Pitch 0 - 60 degrees I �a 877-732-2860 www.snapnrack.com contact@snapnrack.com 2016 by SnapNrack Solar Mounting Solutions.All rights reserved SnapNrackSenm_10o_I3rochure-2.1 C 'A Technical data Sunny Tripower COREl33-US Sunny Tripower COREl50-US Sunny TripowerCOREI62-US se�+lr"a. ,e.,r.s,' ;� ' r) f Id! 0 C,, r o ¢ r F , p • Input[DC) W .I. x 3 � r. r w P •, � „, �,,�.. , °"' ,` M ? k- ,, t �. C-;'`>. •"��•.u, ,,"< `.�} Maximum array power 50000 Wp STC 75000 Wp STC 93750 Wp STC � K Maximum system voltage IOOOV 550 V...800 V 0 0 §V OLT Rated MPP voltage range 330 V...800 V 500 V.--800 V MPPT operating voltage range 150 V...1000 V _, .-- ... .. . .... .____ ._...._,.-.,.,....,.-w ..b....,.-.. ...._..._...,....,,,.._.._..,...,u.,.�.-.:...��.�-...... Minimum DC voltage/start voltage 150 V/188 V MPP trackers/strings per MPP input 6/2 1 Maximum operating input current/per MPP tracker 120A/20A � l Maximum short circuit current per MPPT/per string input 30A/30A 1 w� Output(AC) L �, AC nominal power 33300 W 50000 W 62500 W I > P PLICATIONS Suitable for use as follIewsr :war e x , Maximum apparent ower PP P 33300 VA 53000 VA 66000 VA . FtT Ilse in solar Hera b-cMions COPPER ID y 1 Output phases/line connections 3/3-(N)-PE Nominal AC voltage 480 V 277 V WYE • CONDUCTanS II / Rated 901'IC for Exposed cf concealed wiring in wet or dry locations t, AC voltage range 244 64 305 V 79.5 A • Rated for d ir"_ burial •s 2• Maximum output current 40 A 64 aA a Rated grid frequency 60 Hz Grid frequency/range 50 Hz,60 Hz/-6 Hz...+6Hz r �w j j T -- Power factor of rated power/adjustable displacement 1/0.0 leading....0.0 logging S P s•" C I F I C A ! 1 0 N S �+ ADDITIONAL MATERIALS Harmonics THD <3%b j..y yF Efficiency • Stranded copper conductors' ti + CEC efficiency(preliminary) • 1 -* 1 NIA r(P rY) 97s� 96� 9e, XLP ins.ilatian v'A"I Protection and safety features • UL Subject 4703 L) Load rated DC disconnect 0 t' Load rated AC disconnect • U L 44 1 Ground fault monitoring:Riso/Differential current •/w ■ (,leets the r+-ju irement of U L 85d for TYPE USE-2 UP TO 600 FASTER � , DC AFCI arc-fault protection 0 � i INSTALLATION FOR .� ' ,° Q SunSpec PLC signal for rapid shutdown COMMERCIAL PV SYSTEMS , _ DC reverse polarity protection T �, U I P • AC short circuit protection CD a DC surge protection:Type 2/Type 1+2 0/C) ■ Southwire PV Photowltar Wire is manufactured using stranded copper conductcfs with I°'• AC surge protection:Type 2/Type 1+2 0/0 i Protection class/overvoltage category(as per UL 840) I/IV/ 5hi&- I.7rpr.XLP insulaticin roto. I . s• j '' " General data • Bare or Tinned Conductc-cs '- DRAWN BY Device dimensions(W/H/D) 621 mm/733 mm/569 mm (24.4 in x 28.8 in x 22.4 in) • -40 eO to +90T Device weight 84 kg(1815 lbs) Operating temperature range -25*C...+60*C (-13°F...+140°F) ` F s Sunlight R istdr[t > NENDZA - lyna� temperature r 40 C 1 ) ,�, A+r°�R+om t• Storage range ••-+70°C (•410°F...+58•F � ;- • RoHS Compliant � Audible noise emissions(full power lm and 25°C) 65 d6I(A) p DATE t �.w Internal consumption at night 51M '„ • Dire,=ct Our; I Topology Tranvectionrless /'�• /'� • /� f Cooling Concept O tiCool forced convection,variables speed fans Sam Print Le Td: Bare m Tinned P I P ) z r " Enclosure protection rating Type 4X,3Sx Iasi per UL 50E) ° t SOUTHWI RE E3IU64 (0) (U U PV 1(11 R E 10 AWG (5.26mm-) CU 2000V 9(- Stranded Co"er Maximum permissible relative humidity(non-condensing) 1009 WET OR DRY (-4(TC:)WET.0 R DRY-40-C SUN RES DIRECT B URIAL VW-1 OR Condamrs REVISION(S) SunSpec Additional information Mounting ' t R1-11"N--2 200DV'-R4H'S Certified g Free-standing SLP tn;tili iron DELTA DATE DESIGNER DC connection Amphenol UTX PW connectors Q AC connection Screw terminals-4 AWG to 4/0 AWG CU/AL xX xX xx N/A Fully integrated Increased power,flexibility Enhanced safety,reliability Smart monitoring,control,service LED indicators(Status/Fault/Communication) T o (r ;: :: t „ll'! ;" � Direct Burial Network interfaces:Ethernet/WLAN/RS485 •(2 ports),/./O ; '^ '' l.k ..• • Innovative design requires no •Multiple power ratings for small • Integrated SunSpec PLC signal •Advanced smart inverter grid support Data protocols:SMA Modbus Suns ec Modbus Webconnect 0 2 xxxxxx P / P / •/•/. o -4fl4C to+9C°C N/A additional racking for rooftop to large scale commercial PV for module-leve(rapid shutdown capabilities Multifunction relay � �r IR'SULATtOH installation installations compliance to 2017 NEC • Increased ROI with SMA ennexOS cross OpfiTrac Global Peak(shade-tolerant MPP tracking) � t� l R ' 5TI?4RdS fl1j�I1MAl C.D. HET WEIGHT 71f1CKHE5s nue va" 0 xxxxxx N/A • Integrated DC and AC disconnects • Six MPP trackers for flexible stringing • Next-gen DC AFCI arc-fault sector energy management platform Integrated Plant Control/d on Demand 24/7 •/• c ° jq. 14 O.Cr75 Q220 31,9 and overvoltage protection and maximum power production protection certified to new •SMA Smart Connected proactive O&M Off-Grid capable/SMA Fuel Save Controller compatible 0/0 F • 12 direct string inputs for reduced •OptTroem Global Peak shade Standard UL 16998 solution reduces time spent diagnosing and SMA Smart Connected(proactive monitoring and service support) • a 12 19 0.075 0.237 41.3 ® XX.XX.XX N/A labor and material costs tolerant MPP tracking servicing in the field Certifications(pending as of June 2018) i 10 14 O.W6 D.261 66.$ Certifications and approvals UL 1741,UL 1699B,UL 1998,IEEE 1547,CAN/CSA-C22.2 No.62109 XX XX XX N/A FCC compliance FCC Part 15 Class A �1 8 19 01M.5 Ct 12. 85.7 SUNNY TRIPOWER CORE1 33-US / 50-US / 62-US Grid interconnection standards ; UL 1t-W 5A requen e W HERamp Rae C f 14 7 0,(}75 0.220 31.9 Q XX.XX.XX N/A Advanced grid support capabilities L/HFRT,L/HVRT,Volt-VAr,Volt-Watt,Frequency-Watt,Ramp Rate Control,Fixed Power Factor � ' 12 7 0.075 4.237 41.3 Warranty ` 3 It stands on its own Standard a c 10 7 0.075' D.261 51 .5 PAGE: to yearn • i' Optional extensions 15/20 years a ] o•UG5 D.31 Z. X5.7 r O Optional features •Standard features -Not available 'Preliminary data as of June 2018 - O The Sunny Tripower CORE1 is the world's first free-standing PV inverter for commercial rooftops,carports,ground mount and 11 Type designation STP33-US-41 STP50-U5-41 STP62-US-41 r Other sires and stmnd cant`�Uralticra are aysibble upm l�uesi.Al:a avnitsble in vsricu,colors. 140 repowering legacy solar projects.Now with expanded features and new power classes,the CORE1 is the most versatile,cost- Accessories effective commercial solution available. From distribution to construction to operation, the Sunny Tripower CORE1 enables EQUIPMENT DATA SHEETS logistical, material, labor and service cost reductions. Integrated Suns ec PLC for rapid shutdown and enhanced DC AFCI SMA Dato Manager M SMA Sensor Module Universal Mounfing Sysiem AC Surge Protection Module Kit g P P EDMM-US-10 MD.SEN-US40 UMS_KIT-10 AC_SPD_KITI-IO,AC_SPD KR2 T1T2 arc-fault protection ensure compliance to the latest safety codes and standards. With Sunny Tripower CORE] and SMNs -) _-:) DC Surge Protection Module Kit - ' DC_SPD_KR4l0,DC_SPD_KRS_T1T2 � 6tt!1!t���f7r °� • • ennexOS cross sector energy management platform,system integrators can deliver comprehensive commercial energy solutions for increased ROI. Toll Free +1 888 4 SMA USA y IIE:EC Rh°�lS�^ict°•a�las: OERri�rirn WWW.SMA-Americo.com www.SMA-America.com SMA America, LLC ° PLACARDS - NEC 2014 COMPLIANCE / FIRE DEPT . COMPLIANCE LABELS - NEC 2014 COMPLIANCE r at10 Solar as it should be DETAILS LETTERING QUANTITY APPLIED LOCATION SIGNAGE SUNATION SOLAR SYSTEMS LABEL QTY . LOCATION NOTE 111 REMINGTON BLVD. / RONKONKOMA N.Y. H-119 811 11 $92-514.2414 NEC 000 a i( ?(3} 8 � � AS @EVERY SEPERATION BY ENCLOSURES/ i '.,= .r' ; `,„, ,.LLi NYSERDADC CONDUITS WALLS/PARTITIONS/CEILINGS/FLOORS OR INSTALLER 4355 SEE NOTES INVERTER NO MORE THAN 10 NUMBER PHENOLIC ;ii �i - • 'T� - � �ri 4E�►iC ��i�l +`J® Kiri' 1/4"LETTERS ALL IN WHITE SMA STP 50-US-40 w DOUBLE SIDED TAPE CORE1 3/8” BOLD LETTERS 3/8" BOLD LETTERS °�5-3cnb . Q14 NEGr .3 �E�(21 LIG. P.E. STAMP 4° 1 SPLICE/COMBINER 1 F NEty i�e °': µ @ ANY COMBINER BOX IF USED o r 1/4" LETTERS . ' "` `' 1/4" LETTERS DO NOT DISCONINEOT h�r'�O f 0� irz it;�.sa UNDER LOAD INVERTER 1 INVERTERS 2-4 to- P05-102 ' 2014, 04EC 691 171.E) , QTY. 1 QTY. 1 OF EACH K . ., ;.K. �: x;,� _.._ ._.w... s — .— — x /. ,AR ELECTRIC SHOCK HAZARD Q 11 ,�,• _ ,;�. ,, ;.w4;4>'1 Tag r! LOAD P H-IHEL_"; ;��+!4`� (� �.. N'T47 OPEN FwSITIO"I PHENOLIC 1 PPV PANEL _a ° i. a.�-,x,� wrt.�..".aJ..n,...'i» 1 OF EACH @INTEGRATED DC DISCONNECT -N+a Ai Jt•xrte:t�_e,.•1Jru i:,".rsi.s BOLD UNDERLINED 225A ° �*' ""+ 1 DC DISCONNECT COMPLETE VOLTAGE AND CURRENT VALUES ON 3/8"LETTERS 3/8" BOLD LETTERS ' FOR HEADING IN WHITE MLO ` ^;;;:M #05 ",G4 : 2a14 N;:C�G.S95{F) DISCONNECT LABEL 1/4"LETTERS FOR BODY IN 277/480V WHITE p�yr 11 JL%1A R N1 DOUBLE SIDED TAPE �,,x;;y.,,,"y ,,` �;` � r„ EE ELECTRIC SHOCK HAZARD 1/4" LETTERS ,��.},,. ��.. , ,,-,,,�. THE DIC CONDU01 ORS OF JOB NUMBER THI$PHOTWOLTArIC SYSTELI .APE UFJI3 EN';_! dEZrM10 i!LS htAE E�;_R�l�EL� !v 811 A02-317:2014 NEC 60-0-56(C) CUSTOMER INFO Nq g� p SOUTHOLD TOWN ANIMAL SHELTER }�l P�R� '..II ��,ry1G�"R'1F 1 r 4t 1 INVERTER 1 OF EACH @ SMA STP-US-40 CORE 1 50KW DC PHENOLIC 1 XFMR ill " e t �s- - r `�' 165 PECONIC LANE PECONIC NY 11958 BOLD UNDERLINED 150 KVA _ �I I �� �'�'"° "' ' '�} �'•'� ,t 3/8"LETTERS 3/8 BOLD LETTERS FOR HEADING IN WHITE 1/4"LETTERS FOR BODY IN w.dgf P *""'' 4 U JOB NOTES MITE1/4" LETTERS i y ' �• ' {: `T_.�. . -: #05-182.2814 NEG 690 17{E DOUBLE SIDED TAPE F�"b t ''k /"\WR �I 1'is I. N/A IG ELECTII SIC HD . AC SERVICE 1 OF EACH @ FUSED AC DISCONNECT D�Nn� 1G'RrT:}tlEt�`J�ra�:.S 1 DISCONNECTING COMPLETE VOLTAGE AND CURRENT VALUES ON '°"V,tSON00-11T EVr"TIAMJ MEANS DISCONNECT LABEL lC' 0SIMS W- 11W (h T-C OPE-N FC-SITIO'l 811 Ey'-7f'Y'1Y YL•Piivawrwsa.�sn-.�eeur IMI kt'/++r•il�am L,P':.:.5 91c f:.*1 r?"./ PHENOLIC 1 CO-GEN DISCONNECT F�Orc"o"n 6SWITCHilding is equipped urith an BOLD UNDERLINED Q <j t! • ' �. • � ��3/8"LETTERS 450A NON-FUSED3/8" BOLD LETTERSFOR HEADING IN WHITE onnedted Electric Power LOCATED AT GRADE ie r `1/4"LETTERS FOR BODY IN ON BUILDINGProdt}cf! SOUiCCWHITE EXTERIOR ;�IrlarPhotoval"fltc 1 MAIN DISCONNECT 1 OF EACH @ BUILDING MAIN DISCONNECT PANEL DOUBLE SIDED TAPE esa •1/4" LETTERS nneel3tl lGanpe' PANEL !tear.� LH Sides3/8" BOLD LETTERS __ OtAer•mar 6atcoln �baarlarr BY�rsasee�t«�r51E?.�e��4.tun�trannetangatlrn s.anm n.WF%m 0"i".Art m"rn 811 This Building is equipped with an Interconnected Electric Power PHENOLIC 1 LOCATED ON V,` 1' • 1�1l1tl d Production Source EXISTING MAIN A a'A ` BOLD UNDERLINED DISCONNECT IN ADDITIONAL MATERIALS 3/8"LETTERS ELECTRICAL ROOM 3/Ser BOLD LETTERS yS°t"r'eitmc I. N/A FOR HEADING IN WHITE �s1►II:c.cvalt�lc 1 UTILITY METER 1 @ PSE&G UTILITY METER 1/4"LETTERS FOR BODY INbr WHITE 1/4" LETTERSSaScFrW..— cRear LN ltdr= DOUBLE SIDED TAPE AH S s+e etAer(ACst nab .... -Far sarviao Gal!- INtm wtiort Solar Systems G.32•7.�R?. [�a„aittl tiww..unstl onto to rroys tIm s.c nrn DRAWN BY Q 11 V NENDZA PHENOLIC 1 LOCATED AT SOLARDATE COMMUNICATION ....� 1/4"LETTERS FOR BODY IN EQUIPMENT WHITE Q WHITEDOUBLSIDED TAPE 1/4" LETTERS 12. 21 ° 18 111 � REVISION(S) DELTA DATE DESIGNER xx.xx.xx NIA xxxxxx NIA - 10" ------- LABELS & PLAQUES o xxxxxx NIA CAUTION ® xxxxxx NIA POWER TO THIS SERVICE IS ALSO SUPPLIED FROM SCALE : AS SHOWN SOLAR PV SOURCES WITH DISCONNECTS LOCATED: Q xxxxxx NIA AN DISCONNECT PANELS pNT.IST FLR) PHENOLIC 3 SITE MAP 6 xx.xx NIA 1/4"LETTERS IN WHITE VISIBLE AREA OF BUILDING 1 011 DOUBLE SIDED TAPE PAGE: 11 O 11 SOLAR RAPT SHUTDOWN SWITCH (AT GRADE, N ENTRANCE EXT. OF BUILDING) UnLrrt ET R LABELS PLAQUES XFMR (EXT.AT (PAD MOUNT) GRADE) PHOTOVOLTAIC MODULES AND INVERTERS LOCATED ON ROOF Af SUNation Solar as it should be SUNATION SOLAR SYSTEMS III REMINGTON BLVD. RONKONKOMA N.Y. 11175 PAP XF MF #99494 NYSERDA INSTALLER 15o M 3 NUMBER SSC 208Y/ 120V LIG. P.E. STAMP 1�1 OF NF.W y y 105�61'1, I?�QU I?�b XFMI? PVP rV IMFT1 ?5 �_5 C. ti n SCOWCT 5W rCH I 50kVA 225A MI,O 5MAP1' NVQ\TU\5 Q 250V 450A fused Fri 20BY/ 120V WYE 480Y/ 277V 5MA TI, 33 kW06 0 v,w 5�P\V C� FMP 5ec 480Y/ 277V WYE �4/ 4W 40A OUTPUT @ 480VAC ```���U PSSIOIA���`'�` �XI51' NG Weatherproof NEMA ��P\ P\MU WfT IOCA1�b AfG\Ab� ON PULPING �MP\ 0� — — - - - - � 400A tran5-5 M 1,,- �60 A, �P ACCT # � I � � 60A # Meter 99 82� 750 � IMFMF\ 4W' 208Y/ 120V JOB NUMBER 11," �60 A, 3P Q 2 184roro �P 60 A CUSTOMER INFO SOUTHOLD ANIMAL SHELTER 2 165 PECONIC LANE 0 I PECONIC NY IIS58 �p JOB NOTES j /I 6 0 A I. NIA %00 of 2 ::x 11- �60 A, �P O O �P 60 A INvl # I IP\T t? I / 0AWG GSC #4 GSC 4 I O 5 A, I CommIF 15 A COMMUN CKION ADDITIONAL MATERIALS I. NIA FXffNG �UIUb NG PP-1 PP-2 200A MCS /200A MCS WIRING SCHEDULE 20/ 208 WYE 20/ 208 Identifier Description Rated I,OCA1�b N M �PIN6 I,OCA1'Fb IN M APING p Ampacity Load Phase Conductors Neutral Conductor EGC size Conduit size DRAWN BY EXISTING SS 1 SERVICE 400A 2 SETS 3-1/C 3/0 AWG THWN #3/0 AWG NA 2" DATE �# / CAWG GSC ENTRANCE 2 PV SERVICE 400 A 3-1/C 750 KCM THWN 750 KCM NA 4" REVISION(S)-' ENTRANCE DELTA DATE DESIGNER XX.XX.XX NIA 3 XFMR FEEDER 400 A 370 A 3-1/C 750 KCM THWN 750 KCM #2/0 AWG 4" 0 XX.XX.XX NIA 0 XX.XX.XX NIA 4 PVP FEEDER 225 A 160 A 3-1/C #4/0 AWG THWN #4/0 AWG #2 AWG 2-1/2 ® XX.XX.XX NIA 0 XX.XX.XX NIA INVERTER #10 JXXXXXX NIA CIRCUIT 60 A 40A 3C #6 AWG THWN INSTRUMENTATION #10 1-1/4" SCALE: ONLY - N. T. S. ro COMM CIRCUIT 15A 4A 1 C #12 AWG THWN 1 C #12 AWG THWN #12 3/4" TITLE: THREE-LINE I COMM LINK NA NA CAT 5e NA NA 314"