Loading...
HomeMy WebLinkAbout44407-Z GENERAL NOTES --_ GENERAL DFNIM RtflN Nf171G420 1 THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR THE SUPERVISION OF CONSTRUCTION THE ARCHITECT AND/OR HIS AGENT SHALL BELIST OF DRAWINGS ALLOWED ACCESS TO THE CONSTRUCTION SITE 1 THE SCOPE OF DEMOLITION WORK HAS BEEN GENERALLY INDICATED ON THE DRAWINGS FOR THE G C's INFORMATION I/IA THE G C IS RESPONSIBLE TO DETERMINE THE FULL SCOPE T-100 GENERAL NOTES AND ENERGY ABALYSIS VINCENT BENIC ARCHITECT 2 NO CHANGES SHALL BE MADE TO THESE DRAWINGS ACCEPTAS PER N Y S LAW CHAPTER 987 ANY CHANGES TO THE PLANS MUST BE PO Box 92,Southold 11971971 APPROVED BYTHE ARCHITECT ANY SUCH CHANGES SHALL BE FILED WITH THE BUILDING DEPARTMENTAND AMENDED TO THE ORIGINAL 2 THE G C AND HIS SUB CONTRACTORS SHALL COMPLY WITH ALL LAWS,ORDINANCES AND REGULATIONS BEARING ON SP-001 EXISTING SITE PLAN wwwvbarch com BUILDING PERMIT ANY MODIFICATION OR REPRODUCTION OF THESE PLANS OR SPECIFICATIONS FOR USE OTHER THAN THE INTENDED THE SCOPE OF THE WORK A-100 BASEMENT FLOOR PLAN Issued/Revision PROJECT IS STRICTLY FORBIDDEN WITHOUTTHE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT 3 THE G C SHALL FURNISH ALL LABOR,MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND 3 THE G.0 AND HIS SUB-CONTRACTORS ARE NOT TO SCALE DRAWINGS ALL WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVERALL REMOVAL OF ALL ITEMS SHOWN ON DRAWINGS SCALED DIMENSIONS ALL LARGE SCALE DRAWINGS,PLANS,SECTIONS,ELEVATIONS AND DETAILS WILLTAKE PRECEDENCE OVER SMALL 11/1/19 BUILDING DEPT SCALE DRAWINGS,PLANS,SECTIONS,ELEVATIONS,AND DETAILS 4 ALL ITEMS INDICATED WITHIN THIS SET DRAWINGS SHALL BE REMOVED,AND DISPOSED OF THIS INCLUDES,BUT IS NOT LIMITED TO PLUMBING FIXTURES,LIGHTING FIXTURES,ACCESSORIES,PANTRY CABINETS,APPLIANCES,DOOR 4-7 NOT USED FRAMES,DOOR HARDWARE,ETC. 8 ALL ORIGINAL CONSTRUCTION DOCUMENTS,PHOTOGRAPHS,SKETCHES AND ESTIMATES SHALL REMAIN THE PROPERTY OF THE 5 ALL DEMOLITION WORK SHALL BE SCHEDULED AND COORDINATED AS DETERMINED BY THE OWNER,ARCHITECT AND THE G C ARCHITECTAND SHALL BE CONSIDERED AS INSTRUMENTS OF THE SERVICES RENDERED WHETHER THEY WERE EXECUTED OR NOT 9 THE PHRASE"BY OWNER'IS TO BE CONSTRUED AS PURCHASED BY THE OWNER,BUT COORDINATED,SCHEDULED,HANDLED,AND 6 THE CONSTRUCTION SITE SHALL BE KEPT LOCKED AND SECURE ATALL TIMES INSTALLED,BY THE G C.AND HIS SUBCONTRACTORS 7 THE G C SHALL KEEP THE JOB SITE PROTECTED FROM INCLEMENT WEATHER(RAIN,SNOW,WIND,COLD,HEAT),ETC 10 THE ARCHITECT AND OWNER SHALL APPROVE THE NEW LAYOUT OF ALL PARTITIONS BY MEANS OF CHALK LINE PRIOR TO INSTALLATION 8 PRIOR TO REMOVAL OF WALLS THE G C SHALL VERIFY IF THE WALLS ARE BEARING AND NOTIFY THE ARCHITECT IN 11 THE ARCHITECT,DISCLAIMS ANY RESPONSIBILITY FOR THE DESIGN OF THE ELECTRICAL AND MECHANICAL SYSTEMS WRITING 9 THE G C SHALL PROVIDE ALL NECESSARY SHORING AND OR BRACING REQUIRED TO MAINTAIN THE STRUCTURAL Drawings&specifications as Instruments of professional service 12 THE OWNER SHALL PROVIDE ADEQUATE PROPERTY INSURANCE ON THE VALUE OF THE BUILDING AND THE VALUE OF THE INTEGRITY OF EXISTING BUILDING TO REMAIN are,and shall remain,the property of VINCENT GENIC CONSTRUCTION,INCLUDING FIRE,VANDALISM ETC ARCHITECT No reproduction i in whole or part,shall be made without the written authorization of VINCENN T BENIC ARCHITECT 13 THE COST OF THE BUILDING PERMIT SHALL BE PAID BY THE OWNER 10 THE G C UNDERSTANDS THAT WHERE WALLS ARE TO BE REMOVED,IT SHALL BE UNDERSTOOD THAT HE SHALLALSO BE This document Is Intended solely for the construction of the RESPONSIBLE FOR THE REMOVAL OF ALL ELECTRICAL,TELEPHONE,THERMOSTAT,PLUMBING,DUCTWORK,ETC,INCLUDED project named herein and shall not be used by any other parties IN THE WALL for any other construction without the written consent of 14 THE G C SHALL VISIT THE SITE AND BE RESPONSIBLE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS ANY DISCREPANCIES VINCENT BENIC ARCHITECT SHALL BE REPORTED TO THE ARCHITECT,IMMEDIATELY PRIOR TO AWARD OF CONTRACT,OR START OF WORK THE G C SHALLALSO 11 THE G C SHALL REMOVE AND DISCARD IN ITS ENTIRETY ALL PLUMBING,TO THE POINT OF ORIGIN INCLUDING,SINK, ZONING DATA COORDINATE,AND BE RESPONSIBLE FOR THE APPROVED SIZE AND LOCATION OF ALL OPENINGS THROUGH ROOF,FLOORS WALLS ETC VENTANASTE LINES,HOT/COLD WATER LINES,ACCESSORIES,ETC PREP FOR NEW PLUMBING LAYOUT ALL PLUMBING WORK SHALL BE PREFORMED BY THE LICENSED PLUMBING CONTRACTOR AS PER CODE ADDRESS,1925 Grandview Drive, 15 THE G C AND HIS SUB-CONTRACTORS USING THESE DRAWINGS SHALL COMPLY WITH ALL LAWS,ORDINANCES,AND REGULATIONS, Orient 11957 BEARING ON THE SCOPE AND CONDUCT OF THE WORK ALL STRUCTURAL WORK SHALL BE PREFORMED IN CONFORMANCE WITH ANY CODE 12 THE G C SHALL REMOVE&DISCARD IN ITS ENTIRETY ALL ELECTRICAL LINES INCLUDING OUTLETS SWITCHES TOWN OF SOUTHOLD 1000 OR CODES OF FEDERAL,STATE,COUNTY,OR MUNICIPALITY,HAVING JURISDICTION OVER SUCH WORK TELEPHONE JACKS ETC BACK TO THE PANEL AS REQUIRED BY CODE PREP FOR NEW ELECTRICAL LAYOUT. SECTION 14 16 THE G C.AND HIS SUBCONTRACTORS SHALL BE LICENSED AND INSURED TO DO ALL WORK AS REQUIRED BY THE CITY,VILLAGE,TOWN, 13 THE G C SHALL KEEP THE CONSTRUCTION SITE BROOM CLEAN ATTHE END OF EACH DAY,UNTIL COMPLETION OF BLOCK COUNTY,AND STATE AGENCIES,WHICH MAY HAVE JURISDICTION OVER THOSE TRADES THE CERTIFICATES OF INSURANCE ARE TO BE PROJECT LOT 3 211 FILED WITH THE OWNER PRIOR TO COMMENCEMENT OF ANY WORK BOTH THE OWNER AND THE ARCHITECTARE TO BE LISTED AS ADDITIONAL INSURED AND AS CERTIFICATE HOLDERS AND ARE TO BE HELD HARMLESS FROM ANY CLAIMS EITHER DIRECTLY OR 14 THE G C SHALL NOTIFY AND ASSISTTHE OWNER TO COORDINATE THE INSTALLATION OF BURGLAR ALARM,TELEPHONE ZONE R40 INDIRECTLY ARISING OUT OF THIS CONTRACT AND CABLE TV FROM THE UTILITY POLE TO THE OFFICE BUILDING 17 THE G C AND HIS SUBCONTRACTORS SHALL MAINTAIN WORKMEN'S COMPENSATION INSURANCE AND ADEQUATE LIABILITY INSURANCE DURING THE ENTIRE LENGTH OF THE JOB ENERGY ANALYSIS 18 THE G C SHALL BE RESPONSIBLE FOR THE SAFETY OF THE WORKERS,OWNERS,AND THE PUBLIC,AS REQUIRED BY THE STATE OF NEW YORK,AND OSHA REGULATIONS,DURING THE CONSTRUCTION PERIOD 2016 NEW YORK SRATE ENERGY CONSERVATION CODE 19 THE G C AND HIS SUBCONTRACTORS SHALL BE RESPONSIBLE FOR FILING AND OBTAINING ALL NECESSARY PERMITS,INSPECTIONS, { t •r -} AND CERTIFICATE OF OCCUPANCY,TO PERFORM THE WORK UNDER CONTRACT THE ELECTRICAL,PLUMBING,AND HVAC WORK,SHALL BE SYSTEM COMPONENT CODE REQUIREMENT PROJECT COMPLIANCE FILED UNDER A SEPARATE PERMIT Building Thermal Envelope WOOD FRAME WALL R C402 1 2 R-20 4 y1®q 20 THE G C SHALL NOT STARTANY WORK UNTILTHE BUILDING PERMIT IS ISSUED (BASEMENT ONLY) WALUE R-20 R-20 e y � 21 THE G C SHALL FURNISH ALL LABOR,MATERIALS,EQUIPMENT,AND OTHER ITEMS,NECESSARY TO COMPLETE THE WORK SHOWN, Continuous Insulation L U CALLED FOR,OR INFERRED BY,THESE DRAWINGS UNLESS OTHERWISE NOTED BAEMENT WALL R 04021 2 VALUE R-1 O/R13 R-15 , 22 THE G C SHALL PREFORM HIS WORK SO THATA MINIMUM DISRUPTION IS CAUSED TO THE OWNER,AND PORTIONS OF HOUSE WHERE Continuous Insulation Commucus Insulation THERE IS NO WORK Fenstration C4021 2 r-•µ t"'art: , 23.THE G C SHALL ATALL TIME KEEP THE BUILDING WATER TIGHT,SECURE,AND SAFE FROM OUTSIDERS Replacement U-Faotor o-Factor - `' '_ '• �- ' 35 for Fenestration 45 for FenestranoN 24 THE G C SHALL SUPERVISE AND DIRECT THE WORK USING HIS BEST SKILL AND ATTENTION HE SHALL BE SOLELY RESPONSIBLE FOR ALL -GC SHGC CONSTRUCTION MEANS,METHODS,TECHNIQUES,SEQUENCES,AND PROCEDURES,AND FOR COORDINATING ALL PORTIONS OF THE WORK 040 040 „ UNDER CONTRACT THE G C SHALL BE RESPONSIBLE TO THE OWNERS FOR THE ACTS AND OMISSIONS OF HIS EMPLOYEES, 7 SUBCONTRACTORS,THEIR AGENTS AND THEIR EMPLOYEES PERFORMING THE WORK UNDER CONTRACT 25 THE G C SHALL BE RESPONSIBLE FOR ADEQUATE,TEMPORARY BRACING,SHORING,AND PROTECTING ALL WORK DURING Fenstrauon Fur Leakage NA NA CONSTRUCTION AGAINST DAMAGE,BREAKAGE,COLLAPSE,DISTORTIONS,AND MISALIGNMENT,ACCORDING TO STRICT COMPLIANCE WITH THE NEW YORK STATE BUILDING CODE AND ALL OTHER APPLICABLE NATIONAL,STATE,AND LOCAL CODE,AND GOOD CONSTRUCTION VB lj al INDUSTRY PRACTICE Mechanical&Semce N/A 3 2 Water Heau ng v *- 26 THE G C IS RESPONSIBLE FORALL DAMAGES(INCLUDING STRUCTURES,FINISHES,UTILITIES,EQUIPMENT,VEGETATION,ETC, Systems SCHEDULED TO REMAIN)OF EXISTING PROPERTY AS A RESULT OF HIS WORK,HIS WORKMANSHIP AND SUB-CONTRACTORS THE G C SHALL Lighting&Electncal PROVIDE ADEQUATE PROTECTION FOR THEIR WORKAND BE RESPONSIBLE FOR SAME THE G C SHALL RESTORE TO ORIGINAL CONDITION Systems NIA ANY EXISTING ELEMENTS DAMAGED AS A RESULT OF HIS WORK THE G C.SHALLALSO PROTECT EXISTING OCCUPIED AREA FROM ALL DUST AND DIRT ENERGY CODE COMPLIANCE INSPECTIONS 27 THE G C SHALL COMPLETE ALL WORK INA MANNER THAT CONFORMS TO THE MANUFACTURER'S INSTRUCTIONS AND TO THE HIGHEST Building Thermal Envelope Buildings Above Grade IIA2 Insulat onlacement and R-values 04021,0402 2 _ (� p ASHRAE 901-5 5, , v x014 883 Q� INDUSTRY STANDARDS Mass .(C S 60R 11,581 .• 28.THE G C.SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP AGAINST DEFECTS FORA PERIOD OF ONE YEAR FROM THE DATE OF Fenestration IIA3&IIA3 Fenestration U-Factor and C4023 SUBSTANTIAL COMPLETION AND ACCEPTANCE BY OWNER Replacement Product Rating ASHRAE 90 1-5 S. 56OR 11,582 '® N Vinci Beni: AIA NYS#0149837 ENERGY M__S_1F_R• Prnj€iY 1 TO THE BEST OF MY BELIEF AND KNOWLEDGE,THIS SET OF DRAWINGS MEETS OR EXCEED THE REQUIREMENTS OF THE ENERGY Mechanical&Service N7A `. r�Treanor Residence CONSERVATION CODE OF THE STATE OF NEW YORK LATEST EDITION Water Heating Systems - 1925 Grandview Drive, yste 2 TO THE BEST OF MY BELIEF AND KNOWLEDGE,THIS SET OF DRAWINGS MEETS THE REQUIREMENTS OF THE RESIDENTIAL CODE OF THE SLighting&Electrical N7A Orient 11957 Systems STATE OF NEW YORK LATEST EDITION Drawing Title 3 ALL WINDOWS AND SKYLIGHTS SHALL BE DOUBLE GLAZED,AND WEATHER STRIPPED,AND ALL DOORS SHALLALSO BE WEATHER GENE RAL N OTES STRIPPED NY TO THE BESTOF MY KNOWLEDGE,BELIEF&PROFESSIONAL JUDGEMENT, AND ENERGY ANALYS I S 4 ALL NEW APPLIANCES,AND ITEMS SPECIFIED SHALL MEET THE ENERGY STAR THIS APPLICATION IS IN COMPLIANCE WITH THE 2016 NYCECC F Drawing Number T -100 \ , M3A VINCENT BENIC ARCHITECT `\ `\ PO Box 92,SoutholdNV ll971 www vbarch com \ �\ Issued/Revision 11/1/19 BUILDING DEPT i \ NEW_DKr0 ELLFOR -1kR1=AWAY DRAINAGE \ BY CONTRACTOR -, ----------- Drawings ______ __ Drawings&specifications as instruments of professional service are,and shall remain,the property of VINCENT BENIC ARCHITECT No reproduction,in whole or in part,shall be made EXIST SEPTIC �\ \ without the written authorization of VINCENT BENIC ARCHITECT SYSTEM /� \ This document is Intended solely for the construction of the r . t \ /�` i/' s "fin,_ •' _____'___�� `- project named hereto and shall not be used by any other parties ,\ for any other IC ARCHITECT without the written consent of `\ VINCENT BENIC ARCHITECT NEWAREAWAYS �\ i mow. a SEE A-100 FOR DETAILS `\ / BASEMENT AREA OF S / NEW INTERIOR i ALTERATION i IN EXISTING BUILDING r "' --- i \ 7' INEW DRYWELLFOR \ \� AREAWAY DRAINAGE /-/ BY CONTRACTOR \ i \ ZONING DATA / \\ \ LOT NO 1000 14 02 3 21 \ ZONE R4040 / 540000 ACTUAL \ LOT SIZE 49643 LOTAREA'49.643SF BUILDINGAREA 3089LOT COVERAGE 622 HOUSE AREA:FRONTYARD GARAGE: 614REARYARD STAIR' 30 SF SIDE YARD MIN HOUSE2.245 SFTOTALSIDEYARD TOTAL. 3,089SF / \ MAX HEIGHT 35 FT NO OF STORIES 25 L VB Pro] � I i ®01 s \ EXIST WELL l'9j. C�: ;:'' N EOF N'—=\N Vinci //- NYS#6enic 0149#3IA \\ i' /'/' Project 5 Treanor Residence C / 1925 Grandview Drive, /. Onent11957 1 l� Drawing Title Site Plan jDrawing Number SP_001 VBA' VINCENT BENIC ARCHITECT PO Box 92,Southold NY 11971 wwwvbarch cam Issued/Revision 11/1/19 BUILDING DEPT EXISTING WINDOWS 0 FOUNDATION NOTES: Drawings&specifications as Instruments of professional service 1 BASED ON SOIL BEARING CAPACITY,TWO TON PER SQ INCH CONT EXISTING GYP BD AND INSULATION ON are,and shall remain,the property of VINCENT BENIC SUBJECT TO INSPECTION AND VERIFICATION PERIMETER WALL NEW 1 HR,FIRE ARCHITECT No reproduction,in whole or in part,shall be made 2 ALL FOOTINGS TO BE CARRIED DOWN TO UNDISTURBED SOIL NO RATED WALL without the written authorization solely for VINCENT BENIC ARCHITECT FILLALLCEILING EXIST AIR This document is Intended solely for the construction of the FOOTING SHALL BE SET HIGHER OR LOWER THAN A30 DEGREE p � AND WALL HANDLER project named herein and shall not be used by any other parties ANGLE FROM ANY OTHER FOOTING STEP FOOTINGS ARE TO HAVE A . for any other construction without the written consent of 30 DEGREE MAXIMUM PENETRATIONS VINCENT GENIC ARCHITECT 3 ANCHOR BOLTS TO BEAT LEAST 1/2"IN DIAMETERAND 12"IN AND AROUND PIPES,DUCTS, LENGTH WITH A MAXIMUM SPACING OF 2'-0"ON CENTER CONDUITS WITH 4 ALL CONCRETE TO BE 3000 LB CAPACITY UNLESS OTHERWISE THERERMAFIBRE NOTED OR SPECIFIED EXIST STORAGE/ NEW AND FIRE CAULK 5 ALL WOOD IN CONTACT WITH CONCRETE OR MASONRYTO BE EQUIPMENTNEW C-LABEL RECREATION RAM PATCH ALL OPEN NEW BOILER WOLMANIZED OR PRESSURE TREATED IMPREGNATED WITH NON D RAM FIRE RATED SELF 11060 SF) CEILINGS WITH /AIR HANDLER ABSORBING MATERIAL CLOSING DOOR MIN 5/8 GYP RAM 6 6"POURED CONCRETE SLAB WITH 6X610/10 W W M ON CLEAN BCD COMPACTED FILL NEW C-LABEL FIRE RATED SELF CONCRETE NOTES: CLOSING DOORS 1 NEW FOUNDATION WALL SHALL BE 10"THICK-3000PSI CONCRETE PROVIDEA WALL WITH#4 REBARS AT 24"OC HORIZONTAL NERTICAL COORDINATOR CONTINUOUS ON 20"X10"FOOTING (4)LONGITUDINAL BARS AND#4 EXISTING COLUMNS EXISTING STAIR TO ANDAUTOMATIC TRANSVERSE BARS AT48"OC/12'FROM CORNERS TO REMAIN TYP REMAIN FLUSH BOLT EXISTING BOILER NOTE AND HW TANK PROVIDER SHORING OF FLOOR 000 OO ❑ AND WALL AS NEEDED UNTIL NEW LINTEL IS INSTALLED ° D UP D/ CUT EXITING CONCRETE FOUNDATION WALL TO ACCOMMODATE NEW DOOR PROVIDE NEW STEELIWOOD LINTEL TO (2)ANDERSEN 400 SERIES SUPPORT FLOORS ABOVE WILL BE PROVIDED FRENCJWOOD WITH FUTURE SUBSEQUENT APPLICATION HINGED PATIO DOOR PROVIDE FLASHING AND COVER LINTEL WITH FINISH TRIM MATERIAL EXISTING 60"W X 96"H LOW E GLASS 4 ELECTRIC , PANEL yZ EXISTING CONCRETE o FOUNDATION WALL —v NEW 10'CONCRETE FOUNDATION WALL ON TOP 6'CONCRETE SLAB PITCHED @ 1/4!'/FT _ OF 20"X10FOOTING FOOTING AND PROVIDE CONTINUOUS WATER STOP �G �ENC'I GFA, TO DRAIN SLAB TO BE SET ON A4" -- --------- --- FOUNDATION REINFOECING TO BE PROVIDED BETWEEN NEW AND EXITING CONC ALSO I� GRAVEL BED AND A20MIL VAPOR '� WITH FUTURE SUBSEQUENTAPPLICATION r: :: IN THE E FOOTING KEY TO MEET THE BARRIER??7 -- ---- ---- - ----- WgLL STOP TYP AT ALL INTERSECTION A Pr j# Qeal TYP DRILL AND EPDXY SET 12"LONG#5 _ A -D, - BAR DOWELS AT 24"OC TYPICAL ALONG 1/ NEW FOUNDATION WALL AND EXISTING raw F I PROVIDE LADDERS IN AREAWAY AS PER WALL, eck IC R310 4 2 1 Ladders Ladders or rungs NOTE NEW DRYWALL�FOR STORM WATER shall have an inside width of at least 12 inches - (305 mm),shall project at least 3 inches(76 DRAINAGE DESIGNED AND INSTALLED PROVIDE CONTINUOUS mm)from the wall and shall be spaced not BY CONTRACTOR - WATERPROOFING AROUND THE NEW more than 18 Inches(457 mm)on center CONCRETE MATCHING THE EXISTING IN = '')T'� $8`I J _ (o c)verticallyforthe full height of the area MATERIALAND DEPTH TIE IN NEWp � well Ladders Ladders or rungs shall have an WATERPROOFING TO NEW IN A N 'iT'V_�'` Inside width of at least 12 Inches(305 mm), SEAMLESS CONTINUOUS ASSEMBLY/ shall project at least 3 inches(76 mm)from Vinci the wall and shall be spaced not more than 18 WINDOW AREA CALCULATIONS NYS#00141483 �{IIA, Inches(457 mm)on center(o c)venccally for YS the full height of the area well ROOM NAME SF Project RECREATION ROOM 1060 Treanor Residence REO PERCENT OF WINDOW AREA 10% MIN REQ WINDOW AREA 106 1925 Grandview Drive, PROPOSED WINDOW AREA NO OF UNITS S F EACH TOTAL SF Orient 11957 WINDOW 2'X 41'(EACH) 2 8 16 GLASS DOOR 6'X 8'DOOR 21 481 961 Drawing Title PROPOSED WINDOW AREA 112lf BASEMENT PLAN I ' Drawing Number I A -100 i i