Loading...
HomeMy WebLinkAbout44349-Z -U r\ SOUND VIEW E W INN RENOVATION A ION GREENPORT, N.Y. 11944 58855 COUNTY ROAD 48 bid architecture, dpc GREENPORT, N 11944 31 Wet Main Street.SU tc 205 Patcho0uo, NY 11772 TEL:631 580 2100 FAX:631 580 9760 m,Av baldassano com DESIGNER: Studio Tack 197 Plymouth streot Rrook'yn, NY 11201 TFL:C,40,8r)6.70M) wvs.v sti4otack.con; LEVEL 1 ALTERATION - BLDG ' C ' ISSUED FOR PERMIT SEPTEMBER 23, 2019 DRAWING LIST GENERAL CVR COVER SHEET, KEY PLAN & DRAWING LIST ARCHITECTURAL C-A1.1: FIRST FLOOR-TYPICAL ROOM DEMOLITION PLAN, TYPICAL ROOM CONSTRUCTION PLAN, TYPICAL ROOM RCP/POWER/ DATA PLAN -2 BEDROOM C-A1.2: FIRST FLOOR-TYPICAL ROOM DEMOLITION PLAN, TYPICAL ROOM CONSTRUCTION PLAN, TYPICAL ROOM RCP/ POWER/DATA PLAN - 1 BEDROOM C-A13:SECOND FLOOR-TYPICAL ROOM DEMOLITION PLAN, TYPICAL ROOM CONSTRUCTION PLAN, TYPICAL ROOM RCP/POWER/ DATA PLAN -2 BEDROOM bld orchl*tecture, dpc , C-A1.41:SECOND FLOOR-TYPICAL ROOM DEMOLITION PLAN, TYPICAL ROOM CONSTRUCTION PLAN, TYPICAL ROOM RCP/ POWER/ DATA PLAN - 1 BEDROOM 31 W Main St. s205 C-A2.01: BUILDING 'C' NORTH, SOUTH, EAST, AND WEST ELEVATIONS Patchogue, New York 11772 (631) 580-2100 MATERIAL SYMBOL LEGEND ARCHITECTURAL ABBREVIATIONS: KEY PLAN LEGEND: A F M S PARTITION/WALL TO BE REMOVED ACT ACOUSTICAL CEILING TILE FD FLOOR DRAIN MAN MANUAL EAS•,I FDN FOUNDATION MATL MATERIAL S SINK ADDL ADDITIONAL SCH SCHEDULE FE FIRE EXTINGUISHER MAX MAXIMUM EXISTING PARTITION/WALL TO REMAIN ADJ ADJUST/ADJACENT SCWD SOLID CORE WOOD FIN FINISH MC MEDICINE CABINET ADMIN ADMINISTRATION SD SHOWER DRAIN AFF ABOVE FINISH FLOOR FIXT FIXTURE MCJ MASONRY CONTROL JOINT S/D SMOKE DAMPER CONCRETE NEW 1 HR RATED PARTITION AHU AIR HANDLING UNIT FLASH FLASHING MD METAL DECK •• •�'�•`:' :�" MECH MECHANICAL SDI SOAP DISPENSER ALT ALTERNATE FLEX FLEXIBLE SE SOUTHEAST MEMB MEMBRANE FLUOR FLUORESCENT SECT SECTION o$o� goon° NEW NON-RATED PARTITION ALUM ALUMINUM MTL METAL $'TONE EIEC SECY SECRETARY 000°0000 AL ALUMINUM FRMG FRAMING MEZZ MEZZANINE SF SQUARE FOOT NEW 2HR RATED PARTITION ANUN ANNUNCIATOR FT FOOT/FEET MFR MANUFACTURER SH SHOWER APPROX APPROXIMATE FTG FOOTING MH MANHOLE SHT SHEET GYP. BOARD ARCH ARCHITECTURAL FURR FURRING MIN MINIMUM SHTG SHEATHING AUTO AUTOMATIC FUT FUTURE MIR MIRROR SIM SIMILAR ® WOOD FNISN 6 G MISC MISCELLANEOUS SURF MTD SURFACE MOUNTED MO MASONRY OPENING SPEC SPECIFICATIONS 6 WALL TYPE TAG BD BOARD GA GAUGE MONO MONOLITHIC SQ SQUARE P## P##41, BLDG BUILDING GAL GALLONS MTD MOUNTED SS YD SQUARE YARD 41- BLKG BLOCKING GALV GALVANIZED MULL MULLION SHIM a ST STREET STEEL BO BOTTOM OF GC GENERAL CONTRACTOR N GL GLASS STD STANDARD ® NOT WOOD BLOCKNG �Q BR T BRICK GYP.BNE NORTHEAST ABLE STL STEEL r GR GRADE STRU STORAGE Ol EXISTING DOOR TO BE REMOVED BRG BEARING D. GYPSUM BOARD S NIC NOT IN CONTRACT STRUCTURAL GYP GYPSUM NO NUMBER SUPV UPV SUPERVISOR ® PLYWOOD C SUSP SUSPENDED H NOM NOMINAL CAB CABINET H HEIGHT NRC NOISE REDUCTION S SWITCH EXISTING DOOR TO REMAIN SW SOUTHWEST CANTL CANTILEVER HD HEAD COEFFICIENT SOFTWOOD E CEM CEMENT FICIENT BHDCP HANDICAP NT ATT NSULATION CAP CAPACITY NTS NOT TO SCALE CJ CONTROL JOINT HDR HEADER NW NORTHWEST T E25 NEW DOOR CL CENTER LINE HDW HARDWARE RIGID NSULATIONCMG CEILING HM HOLLOW METAL O TAN TANGENT ROOM NAME 1 HORZ HORIZONTAL OC ON CENTER TBD TACKBOARD CMU CONCRETE MASONRY UNIT TEL TELEPHONE ® ROOM NAME 1 ROOM TAG COL COLUMN HT HEIGHT OD OUTSIDE DIAMETER TEMP TEMPERATURE CARPET 100 CONC CONCRETE HTR HEATER OFF OFFICE T&G TONGUE&GROOVE XXXXXSF CONF CONFERENCE HVAC HEATING,VENTILATION, OH OVERHEAD THRES THRESHOLD �T G CONN CONNECT/-ED/-ION AIR CONDITIONING OPER OPERATOR TOIL TOILET D s�U1� 1�I• �. SECTION NO. CONT CONTINUOS HW HOT WATER OPNG OPENING T.O. TOP OF CONCRETE BLOCK jsj,AN 2 CONST CONSTRUCTION OPP OPPOSITE TOW TOP OF WALL yoN A4.3 SECTION MARK CONTR CONTRACT J PVMT PAVEMENT TOS TOP OF SLAB/STEEL ® PWR POWER TTRANSFORMER COORD COORDINATE BRICK SHEET NO. ID INSIDE DIAMETER P_Q TV TELEVISION CORR CORRIDOR IN INCH TYP TYPICAL CPT CARPET INSUL INSULATION PART PARTITION V UMNUM ELEVATION NO. CT CERAMIC TILE INT INTERIOR PED PEDESTAL U URINAL Da ISSUED FOR PERMIT 2019-09-23 ® AL 3 A3.4 ELEVATION MARK CTR CENTER � PL PLATE °� REVISION: DATE: PL PROPERTY LINE UNO UNLESS NOTED 0 SHEET NO. CUFT CUBIC FEET OTHERWISE ® JAN JANITOR PLAM PLASTIC LAMINATE DRAWING TITLE: CUH CABINET UNIT HEATER JB JUNCTION BOX UTIL UTILITY �; STEEL � 1 PLBG PLUMBING � NORTH ROA CW COLD WATER JST JOIST PLYWD PLYWOOD V _ SITE PLAN, DRAWING LIST DETAIL NO O JTJOINT PNL PANEL VENT VENTILATION — BLDG 'C' -�` _ •.::.::• ABBREVIATIONS DETAIL MARK PR PAIR VERT VERTICAL 7'3 SHEET NO. DEMO DEMOLITION K PRESS PRESSURE DEPT DEPARTMENT PRIM PRIMARY VEST VESTIBULE DET DETAIL KO KNOCK OUT W-X-Y-Z fV�I MATERIAL TAG DF DRINKING FOUNTAIN L PROD PROJECTION PTR PRINTER W WIDTH/WIDE UVER CHWALL MOUNTED EXIT SIGN DIA DIAMETER LLENGTH VR LEOW/ WITH �r SCALE: PVC POLYVINYL CHLORIDE W WIDE FLANGE DIAG DIAGONALVASKErRAL N.T.S. If CEILING MOUNTED EXIT SIGN DIFF DIFFUSER L/LAV LAVATORY R WC WATER CLOSET clom" AWOMAnonwRPA LBS POUND R RISER / RADIUS WD WOOD DRAWN BY: DIM DIMENSION WDW WINDOW SP DISP DISPENSER LF LINEAL FOOT S. E. RA RETURN AIR WHTR WATER HEATER SURFACE MOUNTED FIRE EXTINGUISHER LIN LINEAR RAD RADIATION It is o violation of the Education Law of the State of New York for W/O WITHOUT any person,unless he is acting under the direction of a licensed DIV DIVISION Architect to alter any item on this drawing and/or in this DN DOWN LKR LOCKER RCP REFLECTED CEILING PLAN WT WEIGHT RECESS MOUNTED FIRE EXTINGUISHER CABINET DWG DRAWING LLH LONG LEG HORIZONTAL RD ROOF DRAIN specification in any way. If any such item is altered, the altering (� Architect shall affix to the item his seal and the notation 'altered RECEPT RECEPTACLE DWLS DOWELS LLV LONG LEG VERTICAL REC R ESIUXJ by' followed by his signature and the date of such alteration E LOC LOCATION RECEPT RECEPTION together with a specific description of the alteration. EA EACH OR LOCATE REF REFERENCE EC ELECTRIC CABINET LT LIGHT REF REFRIGERATOR REINF REINFORCE EF EXHAUST FAN LTG LIGHTING REQD REQUIRED EL ELEVATION RES RESISTANT GY ELEC ELECTRICAL RET RETAINING ENTRANCE ELEVATION CE REVERSE/REVISE EELEV NTR `'Y•�Fyt EQ EQUAL RO ROUGH OPENING EQUIP EQUIPMENT RS ROUGH SLAB ici• EXIST EXISTING RV ROOF VENT t; EXP EXPANSION A+ 4 EXT EXTERIOR EWC ELECTRIC WATER COOLER �- %'cam 020193 COPYRIGHT DWG. NO. 19-1029 SOUND VIEW INN RENOVATION GREENPORT, N.Y. ,azo LEGEND PARTITION SCHEDULE ----------------, SOUND VIEW Li L Li1 EXISTING WOOD 2 EXISTING PARTITION TO REMAIN NAILERS,V.I.F. INN N 1 C A1. EXISTING WOOD REPLACE EXISTING BATT V 1 1-HOUR RATED TRUSSES 24"D.C., INSULATION TO FILL CAVITY& RENOVATION 1 1 V.I.F. ACHIEVE MAX.R-VALUE PRIVATE PRIVATE PRIVATE PRIVATE 1 PRIVATE 1 — 1 1 l B. PATIO PATIO PATIO PATIO PATIO P1 PARTITION NUMBER O.CEILING ELEV.9'-0-(V.I.F,) GREENPORT, N.Y. 11944 1 1 NEW SMOKE-TIGHT EXISTING 2X4 STUDS @ 1 1 JOINT W-0-0262,TYP. 16"O.C.(V,I.F.) bld architecture d c 1 1 ROOM #60 ROOM #61 ROOM #62 ROOM #63 ROOM #64 ; EXISTING DOOR TO REMAIN EXISTING PARTITIONS: P1 p _ 1 2X4 DOUBLE STUDS @ •NEW(1)LAYER OF 31 West Main Strrlet,Suite 205 1 1 16"O.C.N.LF.) 518"TYPE X GYPSUM BOARD ONE SIDE ON EXISTING STUD WALLS Pate! ogee, NY 11772 *FINISHED JOINTS •REPLACE EXISTING BATT INSULATION TO FILL CAVITY& TEL:631 �20 2160 1 1 1 1 FAX 631 rH0 9760 LIVING LIVING LIVING LIVING 1 LIVING 1 P1 ACHIEVE MAX,R-VALUE v✓ww.ba dac­nno com ROOM MASTER MASTER ROOM ROOM MASTER MASTER ROOM ROOM i NEW DOOR *NEW(1)LAYER OF BEDROOM BEDROOM BEDROOM BEDROOM 518"TYPE X GYPSUM BOARD ONE DESIGNER: 1 1 T.O.EXISTING SUB-FLOOR 2ND FL. •FDINI3HED EXISTING STUD WALLS Studio Tack ELEV.W-O (W.F.) • REPLACE EXISTING BATT PARTITION SECTION 1 1 PARTITION NOTES B.O.CEILING INSULATION TO FILL CAVITY& (,-,41• SCALE: 3/4"= 1'-0" 197 Plymouth street 3 Z ELEV.9'-0"(V.I.F.) ACHIEVE MAX,R-VALUE E3ronklyn,rJY 11201 FLOOR CONSTRUCTION TYP.(V.I.F): d►?� 1 i �•� TEL:646 86.70,03 •FINISHED WOOD FLOOR 1 1 1. ALL WORK TO BE DONE IN ACCORDANCE WITH NYS BUILDING v.ww.studiotack cnm 1 1 *EXIST.518"PLYWOOD(V.I.F) _ 1 , ,� �, CODE-TABLE 2506.2 AND 2508.1. *EXIST.3/4"SUB-FLOOR(V.I.F.) CL O M. M. O CL CL Q M. Q CL .. .. DINING <01 BTHRM BTHRM DINING DINING BTHRM BTHRM DINING 1 ___ ___ ROOM ------ ' ROOM ROOM ____ ____ ROOM ii a 2X10 FLOOR JOISTS(V.I.F.) rKITCH 2, GYPSUM BOARD: \`••'� \ � `,�, I\ / \�..'� \`..'� \ /I , i i • 518"THICK TYPE FIRE CODE W,UNLESS OTHERWISE r `/ • \/ I I \/ • • \/ I 1 \ / I 1 INDICATED. BTHRM 1 i\\ i\\ l BTHRM BTHRM I \\ //\\ I BTHRM 1 \/ i BTHRM EXISTING(2)2'X4'TOP PLATES \\ 1 STAIR'A' / \1 O STAIR'B' 3. WALLS TO BE FINISHED SHALL BE TAPED,PROPERLY FLUSHED AND (V.I.F.) L, CL CL L. Le CL CL L. 1 SANDED SMOOTH.JOINTS IN FINISHED GYPSUM WALLS TO RECEIVE EXISTING 2"X4"SOLE PLATE(V.I,F.) T--z CL CL �----� T---= CL CL T---c 1 CL CL TAPE AND THREE COATS OF SPACKLE. — t — F 4. PROVIDE ACOUSTICAL SEALANT AT WALL PERIMETERS AND r l I r 1 I 1 1 PENETRATIONS AT ALL NON-RATED WALLS. 1 L_ _J 1 1 t__ _ 1 1 o,T.O.EXIST,1 ST FL.__ _ BEDROOM BEDROOM BEDROOM BEDROOM -f ftN UPELEV.O'-0"UPKITCHEN KITCHEN aaQ �' K{TCHEN KITCHEN — IlBEDROOM FLOOR CONSTRUCTION(V.I.F): rQaa •FINISHED WOOD FLOOR ! // •EXIST,3/4 SUB-FLOOR I F 2 l l I I 1 •EXIST.5/8"PLYWOOD 1 F F-� w r--i ,� ���� i 2X12 FLOOR JOISTS(V,IF.) }DN �' Ems_ �.JT F - _ - --- 1 — ` ---------------' I �- — NOTES P1 TYPICAL SUITE SEPARATION WALL Iroo AREA OF WORK ALL ELECTRICAL WORK TO COMPLY WITH THE 2014(NEC)NATIONAL ELECTRICAL CODE. BUILDING FIRE ALARM SYSTEM TO COMPLY WITH THE 2015 rC� IMARTitiON OTION INTERNATIONAL BUILDING CODE AS ADOPTED BY NYS,THE NEC AND NFPA 72.ALL FIRE ALARM EQUIPMENT SHALL BE UL LISTED. KEY PLAN: BUILDING 'C' rl'N FIRST FLOOR PLAN �11SCALE: 1/8" = 1'41 EXISTING WOOD PRIVATE PRIVATE NOTE: DECK TO REMAIN PATIO PATIO 1.ALL WALL AND CEILING FINISHES TO BE MINIMUM CLASS C RATING 2.ALL FLOOR FINISHES TO BE EXISTING WOOD EXISTING WOOD MINIMUM CLASS II RATING DECK TO REMAIN DECK TO REMAIN NEW EXTERIOR SCONCE AT 3. COORDINATE SPECIFICATIONS OF EXISTING FIXTURE LOCATION REPAIR SLIDING DOORS AS REPAIR SLIDING DOORS AS ALL FINISH MATERIALS WITH FINISH NECESSARY. NECESSARY. SCHEDULE BY STUDIOTACK 4. MODIFY ROUGH-IN PLUMBING AS REQUIRED FOR NEW FIXTURES,TYP. I k\15" 15" � 48" 5" 15' REMOVE EXISTING GYPSUM WALL LIVING LIVING BOARD AND REPLACE WITH 5/8" LIVING ROOM 66" ROOM MASTER TYPE'X' ONE SIDE,TYP. ROOM 66" BEDROOM 2 BEDROOM 6" 66" EXISTING OUTLET AND ADD CEILING SURFACE MOUNT I REMOVE EXISTING FIXTURE AND CONNECT INTO DATA PORT TO BE I EXISTING SWITCH FLOORING AND MOVED VERTICALLY 01511 f BASE AND CONCEALED i NOTE: PATCH AND REPAIR ALL NEW FLOORING AND BASE P 1 BEHIND WALL / " SURFACE FOR NEW FINISHES. THROUGHOUT,TYP. REFER BEDROOM 2 MOUNTED TV 15 TO FINISH PLAN FOR NEW SMOKE DETECTOR FURTHER INFORMATION. 0 4$„.___ REMOVE EXISTING NEW WOOD FLOORING, EXISTINGSMOKE FLOORING AND BASE \ NEW WATER CLOSET TO TYPICAL. DETECTOR O REMAIN S THROUGHOUT,TYP. y REPLACE EXISTING (NO ��� 48" 15" NEW VANITY LIGHT CENTERED CHANGE TO ROUGH ABOVE SINK PLUMBING) NEW SINK FIXTURE TO f NEW DOUBLE SWITCH TO CONTROL CL �l EXISTING SINK FIXTURE AND REPLACE EXISTING NO NEW CARBON coz S " O M. VANITY TO BE REMOVED NEW SINK FIXTURE TO CLOSET 2 O CHANGE TO ROUGH MONOXIDE DETECTOR t 48 4 BATHROOM LIGHTING AND VENT FAN DINING BTHRM REPLACE EXISTING (NO BATHROOM 2 PLUMBING) TO BE HARDWIRED TO NEW RECESSED CEILING FIXTURE AND _. NEW LIGHT FIXTURE t VENT FAN DUCTED TO EXTERIOR, , TO BE REMOVED PLUMBING) NEW WATER CLOSET TO FIRE ALARM PANEL ROOM • a EXISTING TOILET FIXTURE CHANGE TO ROUGH EXISTING ELECTRIC & � CLOSET 2 BATHROOM REFER TO MECHANICAL DRAWINGS , ���` I FOR FURTHER INFORMATION. � REPLACE EXISTING (NO . � I �`� ,�� o CHANGE TO ROUGH �`� 48�� I CO // IPLUMBING) NEW LIGDINING ' o EXISTING SHOWER TO HT FIXTURE BE REMOVED ON DIMMER SWITCH 15" ROOM BATHROOM 1 NEW VX NITY LIGHT K 4'SHOWER CURB \ ISSUED FOR PERMIT 2019-09-23 z� ,' `� BATHROOM 1 / CENTERED ABOVE SINK BTHRM NOTE: REVISION: DATE: NEW SHOWER HEAD AND NEW RECESSED �/ I / � ALL EXISTING PLUMBING I I� ROUGH-INS LOCATIONS TOTRIM AT EXISTING HEAD CEILING FIXTURE AND DRAWING TITLE: I 48" 4'-6" I LOCATION (NO CHANGE TO VENT FAN DUCTED TO f REMAIN. CLOSET 1 EXISTING PASS THROUGH OPENING ROUGH PLUMBING EXTERIOR, REFER TO L. CL CLOSET 1 P 1 ) � CONSTRUCTION PLAN: OPENING TO BE — L. MECHANICAL L. WIDENED. L1-0 L CL CL DRAWINGS FOR 15" 15" /48�� CL \t NEW LIGHT FIXTURE BUILDING 'C': NEW TILE FLOOR FURTHER INFORMATION. e i FIRST FLOOR PROVIDE SADDLE AT DOOR 15" II i �\\ ' ROOM THRESHOLD ROOM 66" 4 SCALE: AS NOTED REMOVE EXISTING ll i #60 NEW WALL #60 ADD NEW OUTLET AND DATA PORT IN NEW CABINETRY IN KITCHEN. ii I _ DRAWN BY: SP ---- BEDROOM NEW KITCHEN CABINETRY, S 15" LOCATION TO BE CONCEALED BEHIND II ROOM COUNTERTOP, PLUMBING i NEW SMOKE 48" WALL MOUNTED TV It is a violation of the Education Law of the State of New York for --- 7 #60 KITCHEN r DETECTOR any person, unless he is acting under the direction of a licensed REMOVE EXISTING FIXTURES AND NEW DOOR, FRAME AND HARDWARE. O o KITCHEN 1---- � � � Q � ���-----�� Architect to alter any item on this drawing and/or in this REMOVE EXISTING t,�'� I APPLIANCES. EXTEND WALL FRAMING AND FINISH 15„ �� specification in any way. If any such item is altered, the altering FOR NEW DOOR. ��� Architect shall affix to the item his seal and the notation "altered RELOCATE SWITCH TO NEW ROOM -_� ll KITCHEN FLOORING AND BEDROOM I REPLACE EXISTING 48, ENTRY.ADD CEILING SURFACE by` followed by his signature and the date of such alteration APPLIANCES IN KITCHEN, 1�==� II O O 1 (\- pit u BASE P 1 EXHAUST FAN. O MOUNT FIXTURE together with a specific description of the alteration. TYP. NEW OPENING FOR DUCTED TO BEDROOM 1 \ NEW DOOR, FRAME AND HARDWARE. VESTIBULE REMOVE EXISTING i __ _° `� i t FUTURE NEW DOOR. EXTERIOR, REFER TO -�ED A,,, CLOSET DOORS AND 1 _ __ --__�� 1 l VESTIBULE MECHANICAL 48" r` Elz e�-Da'`^•�/; ,. MILLWORK. I Ir---- II Il ;� DRAWINGS FOR REMOVE ALL EXISTING I Ill 4_JI CL II �' REMOVE EXISTING o FURTHER 15" t 48" 15" 15" NOTE: r 4,1✓`�'" 7: ".�^'>., 1-��'� . KITCHEN PLUMBING FIXTURES I It___=� — ELECTRICAL AS REQUIRED INFORMATION. CIS z IN THEIR ENTIRETY A ALL OUTLETS, DATA AND SWITCHES ARE EXISTING TO �, r, ->_ NEW SWITCH AND ENTRY REMAIN, U.O.N. CEILING FIXTURE TO NEW VESTIBULE. COPYRIGHT © 201 WIN=1111 DWG. NO. DEMOLITION FLOOR PLAN: CONSTRUCTION FLOOR PLAN: RCP / POWER / DATA 2 BLDG. 'Cl: 2 BR UNIT PLAN #60, 62 3 ) BLDG. 'Cl: 2 BR UNIT PLAN #60, 62 4 BLDG. 'C': 2 BR UNIT PLAN #60, 62 C-A 1.1 SCALE: 1/4"= 1'Z' C-A 1.1 SCALE: 114"= 1'-0" C-A 1.1 SCALE: 114"= 1'-0" NOTE: UNIT #61, 63 ARE OPP. HAND.TYP. NOTE: UNIT #61, 63 ARE OPP. HAND. TYP. NOTE: UNIT #61, 63 ARE OPP. HAND. TYP. 19-1029 SOUND VIEW INN RENOVATION GREENPORT, N.Y. 4 Rip 111 SOUND VIEW U Li INN RENOVATION PRIVATE PRIVATE PRIVATE PRIVATE PRIVATE ' GREENPORT, N.Y. 11944 PATIO PATIO PATIO PATIO PATIO bld architecture, dpc ROOM #60 ROOM #61 ROOM #62 ROOM #63 ROOM #64 31 Wc�,t plain Street,Suit(,205 Patchnr?ne.NY 11772 TEL:631 580 2100 FAX:631 580 9700 vr.^.,w b�ld.3ssano.com LIVING LIVING LIVING LIVING LIVING DESIGNER: ROOM MASTER MASTER ROOM ROOM MASTER. MASTER ROOM ROOM BEDROOM BEDROOM BEDROOM BEDROOM Studio Tack 197 Plymouth SrrP,t Prooklyn,NY 11201 3 2 EL:646.866 7003 \wnv.studiotack.coin CL O M. M. O CL CL �� Q M• Q CL .. ,. DINING DINING DINING DINING i h-*BTHRM BTHRM � � BTHRM BTHRM �ROOM ROOM ROOM __-_ ____ ROOM�,� �,O I\ / \\\/moi ,`,i'/ \ /I fol �' �' if I\ / �\\/moi ,`,i'/ \ /I A,1 \ / i, i, \ i6 +i 1 \ i� i\ \ / 1 VI BTHRM 1 /\ ' ` ' ` /\ 1 BTHRM BTHRM 1 /�\ \ I BTHRM I STAIR'A' ISTAIR'B' CL CL L. L. CL CL L.- -# T--z CL CL -- --Z CL CL -- ------r--- 1— d ,� F------r— I F-Jr BEDROOM BEDROOM _ _° L- BEDROOM BEDROOM -J _ UP �►� KITCHEN KITCHEN 4 ��' KITCHEN KITCHEN a� UP F- 1010 F BEDROOM L L I A- -j IF N2N I I AREA OF WORK KEY PLAN: BUILDING 'C' , 1 FIRST FLOOR PLAN C-A1.2 SCALE: 1/8" = 1'-0" PRIVATE PRIVATE PRIVATE PATIO PATIO PATIO EXISTING WOOD EXISTING WOOD EXISTING WOOD DECK TO REMAIN DECK TO REMAIN DECK TO REMAIN REPAIR SLIDING DOORS AS REPAIR SLIDING DOORS AS NECESSARY. NECESSARY. 15" 15" REMOVE EXISTING GYPSUM LIVING WALL BOARD AND REPLACE ROOM 66" EXISTING OUTLET AND DATA PORT TO BE WITH 5/8"TYPE'X' ONE SIDE, LIVING LIVING MOVED VERTICALLY AND CONCEALED TYP. ROOM ROOM -01 6611 BEHIND WALL MOUNTED TV NEW CEILING SURFACE MOUNT FIXTURE 1 ON DIMMER SWITCH i 15" EXISTING SMOKE \ DETECTOR TO REMAIN \ NEW CARBON �`. 48,1 MONOXIDE DETECTOR TO BE HARDWIRED TO 15" CO2 $ REMOVE EXISTING NEW WOOD FLOORING, EXISTING ELECTRIC & FLOORING AND BASE TYPICAL. FIRE ALARM PANEL THROUGHOUT,TYP. 5" REMOVE CLOSET DOORS--,, 15" SURROUNDING EXISTING ,'���KITCHENETTE�^�, REMOVE ALL EXISTING NEW LIGHT FIXTURE KITCHENETTE KITCHENETTE. NEW \�— 1 \�\� KITCHEN PLUMBING FIXTURES KITCHENETTE ON DIMMER SWITCH APPLIANCES AND o a CABINETRY. ---- IN THEIR ENTIRETY RELOCATE SWITCH AND OUTLET /(� OO o O �'� `� (SHIFT TO SIDE,SO NOT DIRECTLY REMOVE EXISTING +11 s 1 NEW KITCHEN CABINETRY, BEHIND SINK) APPLIANCES IN KITCHEN, !_ _ ___� EXISTING SHOWER TO BE COUNTERTOP, PLUMBING REPLACE EXISTING TYP. REMOVED FIXTURES, AND EXHAUST FAN. \ /I APPLIANCES. DUCTED TO \ NEW TILE FLOORING BTHRM \\ BTHRM BTHRM EXTERIOR, REFER TO __ NEW DOUBLE SWITCH TO- -- \ / 1 MECHANICAL CONTROL BATHROOM �x; EXISTING TOILET FIXTURE TO DRAWINGS FOR ' ' ,4 LIGHTING AND VENT FAN ISSUED FOR PERMIT 2019-09-23 REMOVED FURTHER t 46 REVISION: DATE: / \ ( f/ \I 48 �/i — EXISTING SINK FIXTURE AND INFORMATION. ° / \1 °1r VANITY TO BE REMOVED NEW RECESSED ` 48" DRAWING TITLE: CEILING FIXTURE AND NEW VANITY LIGHT CONSTRUCTION PLAN: CL CL VENT FAN DUCTED { CL CENTERED ABOVE SINK. CLTO EXTERIOR, REFER T CL BUILDING 'C': X — TO MECHANICAL \ 11 `. iDRAWINGS FOR FIRST FLOOR NEW WOOD SLAB CLOSET FURTHER - 811 REMOVE EXISTING CLOSET - DOORS. INFORMATION. DOORS. ROOM SCALE: AS NOTED BEDROOM 15" #64 -- -' -- 66" DRAWN BY: SP ROOM EXISTING OUTLET AND DATA PORT TO BE .� '�I 1 It is a violation of the Education Law of the State of New York for #64 fill) ����I MOVED VERTICALLY AND CONCEALED E31 =T1 BEDROOM —�1 66 any person, unless he is acting under the direction of a licensed BEDROOM —�1 ROOM _�1 BEHIND WALL MOUNTED TV =311 Architect to alter any item on this drawing and/or in this 1 REMOVE EXISTING z 1 #64 . 1 specification in any way. If any such item is altered, the olterin FLOORING AND __t --1 i ADD CEILING SURFACE MOUNT Architect shall affix to the item his seal and the notation "altered BASE I by" followed by his signature and the date of such alteration t FIXTURE AND CONNECT INTO EXISTING together with a specific description of the alteration. SWITCH 48 ✓�r.C`%f R E G r e �, �. .� ^�•, c Vii, • COPYRIGHT ©42 �1 DWG. NO. DEMOLITION FLOOR PLAN: CONSTRUCTION FLOOR PLAN: RCP / POWER / DATA r9% JM 1,111111111"W& 2 BLDG. 'C': i BR UNIT PLAN #64 3 BLDG. 'Cl: 1 BR UNIT PLAN #64r4N\ BLDG. 'C': 1 BR UNIT PLAN #64 C-A1. SCALE: 1/4"= 1'-0" C-A1. SCALE: 114"= 1'-0" C-A1.4 SCALE: 1/4"= 1'-0" " 0 19-1029 SOUND VIEW INN RENOVATION GREENPORT, N.Y. 4 SOUND VIEW ---- INN I ; 2 RENOVATION � PRIVATE, PRIVATE PRIVATE PRIVATE PRIVATE GREENPORT, N.Y. 11944 PATIO PATIO PATIO PATIO 1 PATIO bld architecture, d c ROOM #70 ROOM #71 ROOM #72 ROOM #73 1 ROOM #74 31 w'Gt(lain Street.SL!ite 205 p 1 I Patchogue,NY 11772 1 1 TFL:631 5M 2100 FIX:631 5°0 9760 I 1 N.wv✓.haldassann.com 1 1 LIVINGLIVING LIVING LIVING LIVING DESIGNER: MASTER ROOM MASTER ROOM ROOM MASTER MASTER ROOM I ROOM 1 BEDROOM BEDROOM BEDROOM BEDROOM 1 ' I Studio Tack 1 I 1 I 1 1 197 Plymouth street i Brooklyn, NY 11201 1 I 3 ; ; $ TEL:646.86G.7008 A2� i ; AZ1d wnnnv.stu ;otacF.ccm 1 I 1 1 DINING CL O M. M. O CL DINING DINING CL O B HRM B HRM O CL DINING * %6% _%�� BTHRM BTHRM � 1 --- i ROOM ROOM ROOM ____ 7 A ROOM 1 �\ /i \' '� \` '� \` V I BTHRM 1 v '� \` '� �` v I BTHRM I \ ' i BTHRM 1 BTHRM I /`\ / \ I BTHRM t / \ / \ I I V I /\ 1 STAIR'A' i \\ ��° STAIRS' L. CL CL L. L. CL CL L. 1 T---� CL CL T--z ---� C . CL CL . I — I -----, F- jr BEDROOM BEDROOM - - BEDROOM BEDROOM I 1 -t DNS+ KITCHEN KITCHEN a� �a KITCHEN KITCHEN � i BEDROOM ; ON I 11 vt ----------------# AREA OF WORK KEY PLAN: BUILDING 'C' 1 SECOND FLOOR PLAN C-A1.3 SCALE: 1/8" = 1`-0" NOTE: 1. ALL WALL AND CEILING FINISHES TO BE MINIMUM CLASS C RATING EXISTING WOOD PRIVATE PRIVATE 2. ALL FLOOR FINISHES TO BE DECK TO REMAIN PATIO PATIO MINIMUM CLASS II RATING 3. COORDINATE SPECIFICATIONS OF EXISTING WOOD EXISTING WOOD ALL FINISH MATERIALS WITH FINISH DECK TO REMAIN DECK TO REMAISCHEDULE BY STUDIOTACKN NEW EXTERIOR SCONCE AT 4. MODIFY ROUGH-IN PLUMBING AS EXISTING FIXTURE LOCATION LIDING DOORS AS REPAIR SLIDING DOORS AS kRY. NECESSARY. REQUIRED FOR NEW FIXTURES,TYP. t �\ 15" 48" 5" REMOVE EXISTING GYPSUM WALL 15'LIVING BOARD AND REPLACE WITH 5/8" LIVING TYPE'X' ONE SIDE,TYP. LIVING ROOM 66" ROOM MASTER ROOM EXISTING OUTLET AND 66" BEDROOM 2 „ BEDROOM DATA PORT TO BE 66" MOVED VERTICALLY ADD CEILING SURFACE MOUNT AND CONCEALED I FIXTURE AND CONNECT INTO REMOVE EXISTING BEHIND WALL 1 EXISTING SWITCH FLOORING AND MOUNTED TV 15" BASE �NEW FLOORING N Pl / kND REPAIR ALL I G A D BASE EXISTING SMOKE 15 E FOR NEW FINISHES. THROUGHOUT,TYP. REFER TO� BEDROOM 2 DETECTOR TO REMAIN FINISH PLAN FOR FURTHER __ NEW SMOKE INFORMATION. $"' �' NEW WOOD FLOORING, 4DETECTOR REMOVE EXISTING NEW WATER CLOSET TO TYPICAL. $ FLOORING AND BASE REPLACE EXISTING NO 48" 15" THROUGHOUT,TYP. - ( ,�' NEW VANITY LIGHT CENTERED CHANGE H ABOVE SINK PLUMBING) NEW SINK FIXTURE TO 1 DOUBLE SWITCH TO CONTROL NEW ISSUED FOR PERMIT 2019-09-23 �— CL 1 . 1 M• EXISTING SINK FIXTURE AND O REPLACE EXISTING (NO NEW CARBON coz $ ; 48" 4 � BATHROOM LIGHTING AND VENT FAN VANITY TO BE REMOVED NEW SINK FIXTURE TO CLOSET 2 CHANGE TO ROUGH MONOXIDE DETECTOR REVISION: DATE: DINING BTHRM REPLACE EXISTING (NO BATHROOM 2 PLUMBING) TO BE HARDWIRED TO NEW RECESSED CEILING FIXTURE AND ROOM ° o'er EXISTING TOILET FIXTURE CHANGE TO ROUGH ° EXISTING ELECTRIC & CLOSET 2 t VENT FAN DUCTED TO EXTERIOR, DRAWING TITLE: TO BE REMOVED PLUMBING) NEW WATER CLOSET TO FIRE ALARM PANEL NEW LIGHT FIXTURE BATHR IOM 2 REFER TO MECHANICAL DRAWINGS ------: REPLACE EXISTING (NO `� I FOR FURTHER INFORMATION. CONSTRUCTION PLAN: N�BATHROOM CHANGEOROUGH NEW LIGHT FIXTURE \ 48 1BUILDING 'C : PLUMBING DINING ` 'EXISTING SHOWER TOON DIMMER SWITCH ROOM NEW�ANITY LIGHT � SECOND FLOOR 15BATHROOM 1� \ BE REMOVED 1 4 SHOWER CURB CENTERED ABOVE SINKx . \ ------ BTHRM i %/ \ \ NOTE: NEW SHOWER HEAD AND NEW RECESSED 1 � I / \ ALL EXISTING PLUMBING I /r SCALE: AS NOTED I/ \ ROUGH-INS LOCATIONS TO TRIM AT EXISTING HEAD CEILING FIXTURE AND I 48 4'-6" LOCATION (NO CHANGE TO VENT FAN DUCTED TO 11 DRAWN BY: REMAIN. OPENING P1 ROUGH PLUMBING EXTERIOR, REFER TO 1 CLOSET 1 SP PASS THROUGH L. CL CLOSET 1 ) 1 3 TO BE l 'a CL �• MECHANICAL f It is a violation of the Education Law of the State of New York for — CL DRAWINGS FOR 15" 15" /481. �t NEW LIGHT FIXTURE any person, unless he is acting under the direction of a licensed NEW FLOOR TILE FURTHER INFORMATION. ° L. j Architect to alter any item on this drawing and/or in this '-- NEW WALL specification in any way. If any such item is altered, the altering 48„ CL / Architect sholl affix to the item his seal and the notation 'altered \\ 15 by' followed by his signature and the date of such alteration r — 1 together with a specific description of the alteration. 66" '. D ------- -- it .. . ,�s ROOM ROOM ADD NEW OUTLET AND DATA X� 7 #70 CEJ �,�, EXISTING 11 I NEW KITCHEN CABINETRY, �,�'- $ NEW SMOKE 15" PORT IN NEW LOCATION TO BE `- BEDROOM 1 RY IN KITCHEN. a �___�f BEDROOM 48" DETECTOR CONCEALED BEHIND WALL II ROOM COUNTERTOP, PLUMBING rr 1, FIXTURES,AND #70 KITCHEN NEW DOOR, FRAME AND HARDWARE. MOUNTED TV - REMOVE EXISTING APPLIANCES. O O O Ir''.t/�e� II FLOORING AND EXTEND WALL FRAMING AND FINISH 15 :EXISTING �/ KITCHEN KITCHEN ® RELOCATE SWITCH TO NEW ROOM �__m a FOR NEW DOOR. REPLACE EXISTING 48� =�, u ICES IN KITCHEN, I BASE p p P1 p ENTRY. ADD CEILING SURFACE -•b - r,;0j EXHAUST FAN. BEDROOM 1 MOUNT FIXTURE NEW OPENING FOR DUCTED TO EXISTING _�___ `o I I FUTURE NEW DOOR. NEW DOOR, FRAME AND HARDWARE. EXTERIOR, REFER TO VESTIBULE I i VESTIBULE MECHANICAL 48�� COPYRIGHT © 2, DOORS AND I ---<' I I RK. ----it=-=-- n I I DRAWINGS FOR / :ALL EXISTING I III 4 _Ji u REMOVE EXISTING I Q r, I FURTHER 1 48" „ PLUMBING FIXTURES 1 It---� CL n ELECTRICAL AS ���------e ��� INFORMATION. 15 OS 5 15 NOTE: DWG. NO. ALL OUTLETS, DATA AND ENTIRETY REQUIRED SWITCHES ARE EXISTING TO NEW SWITCH AND ENTRY REMAIN, U.O.N. CEILING FIXTURE TO NEW VESTIBULE. k�r M DEMOLITION FLOOR PLAN: CONSTRUCTION FLOOR PLAN: RCP / POWER / DATA r2_'% BLDG. 'Cl: MODEL UNIT #70, 72, 3 BLDG. 'C': MODEL UNITS #70, 72 4 BLDG. 'C': MODEL UNITS #70, 72 19-1029 C-A 1.3 SCALE: 114"= 1'-0" C-A 1.3 SCALE: 1/4"= 1'-0" C-A 1.3 SCALE: 1/4"= 1'-0" SOUND VIEW INN RENOVATION NOTE: UNIT #71, 73 ARE OPP. HAND.TYP. NOTE: UNIT #71, 73 ARE OPP. HAND. TYP. NOTE: UNIT #71, 73 ARE OPP. HAND.TYP. GREENPORT, N.Y. SOUND VIEW Li INN RENOVATION PRIVATE PRIVATE PRIVATE PRIVATE PRIVATE GREENPORT, N.Y. 11944 PATIO PATIO PATIO PATIO PATIO bld architecture, dpc ROOM #70 ROOM #71 ROOM #72 ROOM #73 ROOM #74 31 Wc,-,t Main Strnet,&,itr,205 Patchogue:, NY 11772 TFL 631 580 2100 FAX:631 589 97f;1 wwvr baldassano.com LIVING MASTER LIVING LIVING LIVING LIVING DESIGNER: ASTER ROOM MROOM ROOM MASTER MASTER ROOM ROOM BEDROOM BEDROOM BEDROOM BEDROOM Studio Tack 197 Plymouth strut Brooklyn, NY 11201 3 2 TFL 611"u.E 36.700E wvAv.studiotack.com CL � _ � CL CL C'O M. M. O CL .. DINING M' M' DINING DINING BTHRM BTHRM DINING _� BTHRM BTHRM C KITCH ' ROOM ROOM ROOM � � .ROOM OA 1` / ���' ��i' \ /r Fol 0 � � I` /\ ' ` ' /\ r BTHRM I �� ' ' /\ I BTHRM ` / I BTHRM BTHRM I / \ / \ I BTHRM I I V I \ STAIR'B' STAIR'A' / \I L. CL CL L. L. CL CL L. �---z CL CL T-- _ --z C CL T---� ® C CL F F �` .: ` -----, ��\\y/ \ter F-Jr- J41d ,GF—Jr- DN BEDROOM BEDROOM a �- BEDROOM BEDROOM DN �+a KITCHEN KITCHEN a� �� KITCHEN KITCHEN �«�ice BEDROOM Ff=1t ==V � �i I i i AREA OF WORK KEY PLAN: BUILDING 'C' 1 SECOND FLOOR PLAN C-A1.4 SCALE: 1/811 = 1'-0" PRIVATE PRIVATE PRIVATE PATIO PATIO PATIO EXISTING WOOD EXISTING WOODIS X TING WOOD E DECK TO REMAIN DECK TO REMAIN DECK TO REMAIN REPAIR SLIDING DOORS AS REPAIR SLIDING DOORS AS NECESSARY. NECESSARY. 15" 15" MID REMOVE EXISTING GYPSUM LIVING WALL BOARD AND REPLACE . WITH S/8"TYPE'X' ONE SIDE, LIVING ROOM 66'� EXISTING OUTLET AND DATA PORT TO BE MOVED VERTICALLY AND CONCEALED TYP. ROOM LIVING 66" BEHIND WALL MOUNTED TV ROOM r NEW CEILING SURFACE MOUNT FIXTURE I I EXISTING SMOKE DETECTOR TO REMAIN t\\ 15„ ON DIMMER SWITCH \ REMOVE EXISTING FLOORING AND BASE NEW CARBON 48” THROUGHOUT,TYP. MONOXIDE DETECTOR TO BE HARDWIRED TO 15" C02 S ` EXISTING ELECTRIC & REMOVE CLOSET DOORS FIRE ALARM PANEL SURROUNDING EXISTING NEW WOOD FLOORING, KITCHENETTE. NEW TYPICAL. 5" APPLIANCES AND CABINETRY. KITCHENETTE NEW LIGHT FIXTURE �� 15" REMOVE ALL EXISTING�\\ �i �\\\ KITCHENETTE KITCHENETTE KITCHEN PLUMBING FIXTURES ON DIMMER SWITCH ---- ° ° IN THEIR ENTIRETY — RELOCATE SWITCH AND OUTLET ISSUED FOR PERMIT 2019-09-23 (SHIFT TO SIDE,SO NOT DIRECTLY REMOVE EXISTING III ' I NEW KITCHEN CABINETRY, BEHIND SINK Ir\Jrllrm r`;/ IL____JI� O OO ) REVISION: DATE: APPLIANCES IN KITCHEN, L`_ _!t_ _� EXISTING SHOWER TO BE COUNTERTOP, PLUMBING REPLACE EXISTING- APPLIANCES TYP. REMOVED FIXTURES,AND EXHAUST FAN. DRAWING TITLE: \ /I APPLIANCES. DUCTED TO \ / I EXTERIOR, REFER TO NEW DOUBLE SWITCH TO CONSTRUCTION PLAN: \\ /' BTHRM BTHRM MECHANICAL BTHRM ��`� CONTROL BATHROOM BUILDING C': \z/ r EXISTING TOILET FIXTURE TO DRAWINGS FOR ® �4 LIGHTING AND VENT FAN BE REMOVED FURTHER ; SECOND FLOOR 4 „ AND INFORMATION. VANITY TO BE REMOVED o � \\`I oFl 48' NEW RECESSED SCALE: AS NOTED CL CL CEILING FIXTURE AND NEW VANITY LIGHT CL CL VENT FAN DUCTED 41 CENTERED ABOVE SINK. DRAWN BY: SP NEW TILE FLOORING TO EXTERIOR, REFER — X TO MECHANICAL \ It is a violation of the Education Law of the State of New York for DRAWINGS FOR ___ any person, unless he is acting under the direction of a licensed FURTHER $ Architect to alter any item on this drawing and/or in this REMOVE EXISTING CLOSET INFORMATION. specification in any way. If any such item is altered, the altering Architect shall affix to the item his seal and the notation "altered DOORS. NEW WOOD SLAB CLOSET DOORS. 15" ROOM by" followed by his signature and the date of such alteration BEDROOM #74 together with a specific description of the alteration. 66-1 �. cr_D ROOM -- -- : #74 r��ri ('P EXISTING OUTLET AND DATA ��\ ,?- ....-" BEDROOM ROOM �' I _ i _ I 66' PORT TO BE MOVED VERTICALLY ✓ EDROOM s��, �. REMOVE EXISTING —�I #74 AND CONCEALED BEHIND WALL FLOORING AND ``°%i �`: i MOUNTED TV BASE i ADD CEILING SURFACE MOUNT a t FIXTURE AND CONNECT INTO r ~- 15" \\ EXISTING SWITCH Ura 0 COPYRIGHT DWG. NO. DEMOLITION FLOOR PLAN: CONSTRUCTION FLOOR PLAN: RCP / POWER / DATA 2 BLDG. 'C': 1 BR UNIT PLAN 3 BLDG. 'C': 1 BR UNIT PLAN 4 BLDG. 'C': 1 BR UNIT PLAN SCALE: 114"= 1'-0" C-Al. SCALE: 114!'= 1'-0" C-A1. SCALE: 114"= 1'-0" 19-1029 SOUND VIEW INN RENOVATION GREENPORT, N.Y. 3 SOUND VIEW INN RENOVATION GREENPORT, N.Y. 11944 77, bid architecture, dpc 9 31 West Main Street,Suite 205 f'otrhon�le. NY 11772 TL t:631 580 2100 FAX 631 580 9760 vmn haldassano com DESIGNER: 1 HffM77 1 1 1 1 Studio Tack 197 Plymouth street EM Brooklyn,NY 11201 V111 111111 111HI 1�1 1111' [E[M ' ME 11111111 1!A 11 TEL646 8(-,0.70OF 4vivw.studiotack com ao 00 0o ao as �6 ao as 8 5 5 as 00 Lij /�71 SOUTH ELEVATION A2.0 SCALE: 1/8" = 1'-0" $ Qs .... (D— (D— 9 5 6 6 5 K'2-'N) EAST ELEVATION 3 WEST ELEVATION A2.0 SCALE: 1/8" = 1'-0" A2.0 SCALE: 118" = 1'-0" 3 ISSUED FOR PERMIT 2019-09-23 9 REVISION: DATE: DRAWING TITLE: EXTERIOR ELEVATIONS O L(D. O O OT O (DL SCALE: 3/16#1 = 1'-0" 1E1 Ell 111111 IITHHHI�Hffi mm- idftllffid�ll 1111111111111 110THHHH111 HNIHHHH1 ITHIffifl, 11111111111111 1INTHHHH111, I 1HTHHHH1 HHH1 111111111111111 11011[m E1H$HH[ffMT DRAWN BY: SP It is a violation of the Education Low of the State of New York for any person, unless he is acting under the direction of a licensed Architect to alter any item on this drawing and/or in this specification in any way. If any such item is altered, the altering Architect shall affix to the item his seal and the notation "altered by"followed by his signature and the date of such alteration O O CD together with a specific description of the alteration. O O O O O O F r7l F7 1 7 F-1 F KEY NOTES —7 F O1 PAINT EXISTING DOORS,REMOVE PANELING TRIM IF POSSIBLE, O EXISTING SLIDING DOORS I WINDOWS TO REMAIN,REPAIR AS NECESSARY. .~� O ROOF TO REMAIN AS IS. O NOT USED. O5 PAINT EXISTING STAIRCASE,REPAIR AND MAINTAIN AS NECESSARY. COPYRIGHT © 2 r-4' NORTH ELEVATION o PAINT BRICK SIDING,TYPICAL ALL SIDES. DWG. NO. ��-�oSCALE: 1 18" 1,-0" O PAINT EXISTING TERRACE DIVIDING WALLS. Og PAINT EXISTING SIDING,TYPICAL THROUGHOUT, O9 NEW LIGHT FIXTURES TO REPLACE EXISTING,TYPICAL ALL LOCATIONS. 19-1029 SOUND VIEW INN RENOVATION GREENPORT, N.Y. GENERAL A. ALL WORK COVERED UNDER THE FOLLOWING HVAC SPECIFICATIONS AND CONTRACT DRAWINGS ARE TO BE PROVIDED AND INSTALLED BY AND IS TO BE THE RESPONSIBILITY OF THE HVAC CONTRACTOR. B. THE HVAC CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED COMPONENTS AND ACCESSORIES NECESSARY TO FACILITATE A COMPLETE INSTALLATION INCLUDING ALL LABOR REQUIRED TO COMPLETE THE INSTALLATION. THE HVAC CONTRACTOR IS _. "".. ... ........... _.........._... ._ ....':................. . ........ �..., ,.., �....... ........... .............................._..._...................... wµ:.. " _... .. . .... ..€ ....................__................._......_. ............f ONSIBLE FOR UNLOADING,ASSEMBLING AND INSTALLING ALL HVAC EQUIPMENT P RELATED ITEMS UNLESS OTHERWISE SPECIFIED. 3 { i C. THE HVAC CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE PROJECT AND SHALL WITH OTHER CONTRACTORS TE W NT TORS DOING WORK IN THE BUILDING IF ANY ONFLICT,INTERFERENCE OR DISCREPANCIES COME TO THE ATTENTION OF THE HVAC : " CONTRACTOR,HE SHALL NOTIFY THE ENGINEER IMMEDIATELY,BEFORE PROCEEDING ANY FURTHER WITH THE INSTALLATION. AREX OF WORK D. NO ADDITIONAL PAYMENT OVER AND ABOVE THE HVAC CONTRACT PRICE WILL BE r, € E , E f i € < MADE UNLESS THE HVAC C CONTRACTOR RECEIVES A WRITTEN ORDER BY THE OWNER OR OWNERS REPRESENTATIVE FOR ADDITIONAL WORK. a x £< p ,» g§g., E. PRIOR TO §� }s;{_,�••£}k%•••;'ptf, ..' LBPROPOSALS,THE HVAC CONTRACTOR SHALL ALL DRAWINGS, SPECIFICATIONS,AND OTHER VAILABLE ESTIMATING DATA T 0'; r ;y AND SHALL BECOME FULLY INFORMED AS zO THE EXTENT AND CHARACTER OF THE EY , HVAC WORK REQUIRED AND ITS RELATION TO THE OTHER WORK IN THIS PROJECT.NO CONSIDERATION WILL BE GIVEN FOR ANY ALLEGED MISUNDERSTANDINGS OF THE MATERIALS TO BE FURNISHED OR WORK TO BE DONE;IT SHALL BE CLEARLY UNDERSTOOD THAT THE SUBMISSION OF A PROPOSAL INDICATES A COMPLETE !" ¢' UNDERSTANDING OF ANY AGREEMENT TO ALL THE ITEMS AND CONDITIONS SPECIFIED , � HEREIN R INDICATED O CATED ON THE DRAWINGS. E. � WINGS. CLa € r, P} !r ::r ;°syy :s DESIGN : :``Z BEDRJOM UNIT=--- ?- "-" 2 :BEDRC)OM UNIT-= 2 `BI=DROOM UNIT` "�2 BI=DROOM UNITrF - 1-BEDROOM CONDITIONS a A. OUTDOOR DESIGN CONDITIONS ARE TO NF UNIT CONFORM TO VALUES FOR THE SPECIFIC up f SOUTL I LOCATION A OUTLINED IN ANSI/ASHRAE/ACCA STANDARD 183 ,- 77 § f 7 § 3 , , % , , ".,., �:.:,,,._. ,,.n ,. �,., ,,,. R... KN<:,,�� , ;ba _ ;, SCOPE OF WORK _ .,,,,,.v,,,y} »..f,S•, 3 r �,t. ' „v,.r,,,w..a.,,,,..4"H €.u,...,".�. ,..W.J w.;w•�f_"" .S 8 I { s r„mow, t I� S 1 }, A. HVA CONTRACTOR ITECERTIFICATES OF INSPECTION FOR HIS WORK AND DELIVER TO THE ENGINEER BEFORE ACCEPTANCE AND FINAL PAYMENT FOR THE WORK.THE HVAC CONTRACTOR SHALL INCLUDE IN HIS SCOPE OF V ["� E ! _ OST TO THE OWNE ALL LABOR MATERIALS SERVICES, ” -- } WORK WITHOUT EXTRA C R, ',.is ,,,', - ;,',,.:£ � •:;-'srs,: ,:z,"�'". „� },f;x ti -;5,: E�ja n,�'D E ._ ...W.,.:,g,. ..,.,.,_ x U- APPARATUS DRAWINGS (IN ADDITION TO CONTRACT DRAWINGS 3...,..,._ ,,,,,._._ .:: e} ..,..,..",.,...". �5 s` ,,,,,,,, ,,,,,,,,, "}•4,%,,, ...... .. .,,,.,,,, %, ,,.,","..,.," ',µif,.' <�•'.,,f i"� " _ _ � i e,,,,,.�. ;� �,,��,�` �~ �•- ,r�'-.,'.,, '- ` �' ""...... "..""........ i.w_ _.�µ..� ORDER TO COMPLY WITH ALL APPLICABLE CODES, S, ORDINANCES,RULES AND � REGULATION I ... y: } ,§ y C' 4 3, r' 5 , I gy r » ..is ,! FURNISHED AND ALL SHALL BE IN STRICT £ r. E ALL MATERIALS WORK INSTALLED _."..............__,"."..: _........"......"..._._..."__.".. _____F ____ ;"' ACCORDANCE WITH THE REQUIREMENTS OF THE OWNER AND ALL APPLICABLE LOCAL � CODES AND REGULATIONS. 6 E C. SCOPE OF WORK SHALL INCLUDE THE INSTALLATION OF NEW HVAC DUCT,REGISTERS, GRILLES,EXHAUST FANS THE INSTALLATION OF A NEW ROOFTOP UNIT AND THE RELOCATION OF EXISTING ROOFTOP UNITS. FIRST FLOOR PLAN D. ALL PROPOSED RIGID DUCT INDICATED ON PLAN TO BE CONSTRUCTED AS SPECIFIED IN SCALE: 1/8" = V-0" THE SMACNA DUCT CONSTRUCTION STANDARDS. E. ALL PROPOSED FLEX DUCT SHALL CONFORM TO ICC INTERNATIONAL MECHANICAL LEGEND CODE/2015 IMC. F. RECTANGULAR DUCT SPACING SHALL BE IN STRICT ACCORDANCE WITH ICC INTERNATIONAL MECHANICAL CODE,2015. IMC APPROVED HANGERS SHALL SUPPORT '�— Exhaust Duct DUCTS AT INTERVALS NOT EXCEEDING 10 FEET. ................................:................_............_.................. . . .........._.. .. . ......y... G. ALL PROPOSED DUCTS WILL BE LOCATED WITHIN CONDITIONED SPACE. Bathroom Exhaust Fan H. RETURN PLENUM TO BE WITHIN CONDITIONED SPACE. E i€ �x !_ " I. AIR DISTRUBUTION SYSTEM SHALL BE DESIGNED AND INSTALLED TO SUPPLY THE Under Cabinet Kitchen Exhaust Hood REQUIRED DISTRUBUTION OF AIR. THE INSTALLATION OF AN AIR DISTRUBUTION i i SYSTEM SHALL NOT AFFECT THE FIRE PROTECTION REQUIREMENTS SPECIFIED IN THE ICC INTERNATIONAL BUILDING CODE. CONTRACT DRAWINGS ® Duct up/dn A S G ARRANGEMENT AND THE INTENDED T SHOW THE GENERAL Duct up/dn EXTENT OF THE WORK TO BE DONE,HOWEVER,THE EXACT LOCATION AND r ARRANGEMENT OF ALL PARTS SHALL BE DETERMINED AS THE WORK PROGRESSES. I I} s v Q B. THE LOCATIONS OF ALL DUCTS AND EQUIPMENT AS SHOWN ON THE PLANS ARE g= r I APPROXIMATELY CORRECT,BUT THEY ARE SUBJECT TO SUCH MODIFICATIONS AS MAY BE NECESSARY AT THE TIME OF INSTALLATION TO MEET ANY CONDITIONS. SUCH BE I' IMMEDIATELY REVIEWED WITH THE ENGINEER AND INSTITUTED BY THE HVAC CONTRACTOR WITHOUT EXTRA COST.2015 IMC CODE EVALUATION i. a-ba..r.,,,,.," I� CODE SECTION REQUIRED PROVIDED C. THE LOCATIONS OF ALL PARTS AND EQUIPMENT SHALL BE COORDINATED WITH THE ., _. s WORK OF ALL OTHER TRADES PRIOR TO SUBMITTING SHOP DRAWINGS FOR L E FABRICATION AN IPMENT PURCHASE APPROVAL LOCAL EXHAUST: LOCAL EXHAUST SYSTEMS SHALL B D EQUIPMENT PROVIDED IN KITCHENS, BATHROOMS AND TOILET ROOMS AND SHALL HAVE THE CAPACITY TO EXHAUST 403.3.2.3 THE MINIMUM AIRFLOW RATE DESCRIBED BELOW ..; � KITCHENS' 100CFM INTERMITTENT OR 25 CFM CONTINUOUS BATHROOMS AND TOILET ROOMS: f k Ex . '„ 50CFM INTERMITTENT OR 25 CFM CONTINUOUS. 6"0 UP EXHAUST FAN SCHEDULE CD / 5 s 3.25"x 10I --' -" Model Manuf. Use Qty Duct Size CFM Electrical Data Notes UP REV DATE Ams - Interlocked with bathroom CK DESCRIPTION , Watts I' 3.' k Q7XE080 BROAN BATHROOMS 9 6" , light switch-80cfm ",_,_„_.... REVISIONS _. - Roof exhaust r.. E” " r S ewa ` 2 23.3 o as noted. SOUND V D VIE T E ' 7"OR 3.25" 110Av /300 - Finish TBD g _ GREENPORT, NY BCDF130 BROAN KITCHENS 4 x10" Max •65 78 Roof or Sidewall exhaust as noted. FOR PERMIT 0 FIRST FLOOR - 2 BEDROOM APARTMENT FIRST FLOOR - 1 BEDROOM APARTMENT TYPICAL RCP TYPICAL RCP J.R. L MACHER P.E. LLC CD Cq SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" `. F `` ° ... �;� -. q The Thud Generation of Excellence In Water Supply Water Resources C14 hfr P__O .P a :":` t Vis. ,` , Civil and Environmental Engineering VC I 0 APPLICABLE CODES ,� s 3555 Veterans Memorial Highway, Suite A, Ronkonkoma, NY 11779 ICC INTERNATIONAL MECHANICAL CODE IMC 2015 r" PHONE: (631)234-2220 FAX.- (631)234-2221 E-MAIL: info@holzmacher.com o - ICC INTERNATIONAL EXISTING BUILDING CODE(IEBC),2015 Jsti`t," � `'? ..s.-' SHEET TITLE: USE GROUP CLASSIFICATION a-3' MECHANICAL RENOVATION PLAN - FIRST FLOOR DO DESIGNED BY: SCALE: R-2 -BUSINESS MPK As Noted BUILDING HEIGHT �jr. .�<��;�• � - TWO(2) STORIES REVIEWED BY: DATE: JRH Sept. 16, 2019 1 V♦i 111 j ALTERATION OF THIS DOCUMENT EXCEPT BY A PLAN SHEET BY: PROJECT NO: LICENSED PROFESSIONAL IS ILLEGAL MPK O POWER CABLE HANGER BARS (spun up to 24" ROOF PANEL HOUSING_ m ROOF PANEL / �I RIB OR SEAM PRE—MANUFACTURED E (, FLEXIBLE PIPE FLASHING, WEATHER— PROOF 3 "E � - P,,._'�� i i P,^,� _ I {wl.:.11€lo _ VENT PIPE — I ', }€ REF. MECH. CEILING AREA OF WORK ROOF PANEL CEILING j i RIB OR SEAM MATERAL �iF3tLL.E JOIST t 3i 5'+ ££ i s1 z { £} qq s3 I w! < s ; DETAIL A DETAIL B ROOF EXHAUST PIPE FLASHING BATHROOM EXHAUST FAN MOUNTING , 1" a 4 < <f y" <�,,.,.. a ry 0 .,. .,f«_,,,,,., 4; i II si„ mm r , __..... SCALE NTS SCALE NTS I Axl, �! ;I v Y b Ham; � EI »,��,;,,,�•,.�. {5 I /y Ax •� £ ./L t z,r p ! v �'} bb I r„ : , : UNIT'""`;. ., 11_:<,_ 2 BED..ROOM :;<; :i BEDROOM UNIT, I OF P2 BEDROOM UNIT2 BEDROOM UNIT-£ Ei „ <nw Ip„",,,,.,•,_,__,.,,._,.",".,...,f� _.....-._< <_ ._....,_ 'X /4UINSULATION IAF CSP} .z7 R OUND C uCT (Place. -in over Fan Housing.) „ HAo(FORVERTICAL(with built DISC HOUSING FAN i M a CHILE erns short r { s I � � POWER �� K dUCt af:?FFI1- •.. < ml, HOUSE WIRING I e 1 ;E .,.} .,,,, b,� ,..1, w 3i 5i t P £1;:. >., ., ., ,"E, OI R BACK _ .... ...__ ABINETHOOD g Seal gaps r Ea � rou d r. Y r WALL P I = € , „ l ;'"v — Housln .t �,,�.•r"' i, r _ HOOD 6-IN. ROUND DUCT' . %., � Seal duct .. WALL CAP* 31/4” X 1 O" � UCT _.._._... .....__........__._...._ _....._ ___ �__ _"_ _..__ _ _ ..__..___...__.......__ .. . ......._..... .."_...". _.....,,_ _._"......_"..... .......... _..._.._"_..........,,_"..._..".._.... ._._""_.... . . joints.[�fl �-l{�I. *, �` (with built-In n '� *Purchase tape. FtOUNI� separately. ELBOWS* damper) 3 MIN - 24M� (FOR HORIZONTAL DISCHARGE: ABOVE COOKING SURFACE SECOND FLOOR PLAN DETAIL C DETAIL D SCALD 1/8" - 1'-0" BATHROOM EXHAUST FAN INSTALLATION KITCHEN EXHAUST DUCT INSTALLATION SCALES NTS SCALEI NTS LEGEND E.�haust Duct __ ... . ..-_._.""__._.___.........._. ". .....__". _.,_,"______......._... µ Fo Bathroom Exhaust Fan IS 33 E E Under Cabinet Kitchen Exhaust Hood t Duct up/dn Duct up/dn I I }I j€ EXHAUST FAN SCHEDULE vl, r Model Manuf. Use Qty Duct Size CFM Electrical Data Notes ` I f Amps I bathroom - y. j Watts Interlocked with light switch-80cfm QTXE080 BROAN BATHROOMS 9 6" 80 'I. �� � tt -Roof exhaust to roofcap TO ROOF .2 23.3 with built-in damper. r ;, TO ROOF � 110Avg/300 -Finish TBD BCDF130 BROAN KITCHENS 5 7" Max 65 78 -' - Roof exhaust to roofcap with built-in damper. UP FROM -> SRC 3& !'' FIRST FLOOR Ely: I I TO ROOF I UP FROM E FIRST FLOOR I , TO ROOF i, , < IJP FROM --� x f FIRST FLOOR ' !I 'TO ROOF ' ,£: I ,: F'�" REV DATE CK DESCRIPTION ; , T 0 ROOF ._......_, " s t „r. r SOUND VIEW INN GREENPORT,NY C 3 N FOR PERMIT 3 ° SECOND FLOOR - 2 BEDROOM APARTMENT SECOND FLOOR - 1 BEDROOM APARTMENT TYPICAL RCP TYPICAL RCP J.R. �, AC P.E. LLC N SCALE: 1/8" = 1'-0" _ SCALE: 1/8" 1'-0" �''�"$= '� ; The Third of Excellence � Generation o Excellence In Water Supply, Water Resources, Civil and Environmental Engineering 3555 Veterans Memorial Highway, Suite A, Ronkonkoma, NY 11779 , PHONE: (631)234-2220 FAX.- (631)234-2221 E-MAIL:info@holzmacher.com E �;._ `t l P s a SHEET TITLE: F' MECHANICAL RENOVATION PLAN - SECOND FLOOR DESIGNED BY: MPK SCALE: As Noted REVIEWED BY: DATE: JRH Sept. 1 b, 2019 111♦♦♦1-2 a ALTERATION OF THIS DOCUMENT EXCEPT BYA PLAN SHEET BY: PROJECT NO: LICENSED PROFESSIONAL IS ILLEGAL. MPK 0