Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
43986-Z
ofFOZM� Cdy, Town of Southold 10/9/2019 o t P.O.Box 1179 v' T r 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 40758 Date: 10/9/2019 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 2155 Grand Ave, Mattituck SCTM#: 473889 Sec/Block/Lot: 107.-8-4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/11/2019 pursuant to which Building Permit No. 43986 dated 7/19/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof mounted solar panels as applied for. The certificate is issued to Plaia,Catherine&Antonakopoulos,Theresa of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 43986 10/2/2019 PLUMBERS CERTIFICATION DATED Authorized Signature 1 tk`-� TOWN OF SOUTHOLD ��FFoBUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 43986 Date: 7/19/2019 Permission is hereby granted to: Plaia, Catherine 120 89th St Howard Beach, NY 11414 To: install solar panels as applied for. At premises located at: 2155 Grand Ave, Mattituck SCTM # 473889 Sec/Block/Lot# 107.-8-4 Pursuant to application dated 7/11/2019 and approved by the Building Inspector. To expire on 1/17/2021. Fees: SOLAR PANELS $50.00 CO -ALTERA O LING $50.00 ELECT R $100.00 To 1: $200.00 1 Buil ing Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9,1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. 7/11/19 New Construction: Solar Panels Old or Pre-existing Building: (check one) Location of Property: 2155 Grand Avenue Mattituck House No. Street Hamlet Owner or Owners of Property: Catherine Plaia Suffolk County Tax Map No 1000, Section j n7 Block R Lot 4 Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Sung Lee/Momentum Solar Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ ApplicantSignature Building Department Application AUTHORIZATION (Where the Applicant is not the Owner) j� Catherine Plaia residing at 2155 Grand Avenue, Mattituck,NY 11952 (Print property owner's name) (Mailing Address) do hereby authorize Sung Lee/Momentum Solar (Agent) to apply on my behalf to the Southold Building Department. 7/11/19 wner's Sign r ) (Date) Catherine Plaia (Print Owner's Name) pE SO(/r�®l Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 G sean.devlinCaD-town.Southold.ny.us Southold,NY 11971-0959 olyc®UNrI,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICAL COMPLIANCE SITE LOCATION Issued To: Catherine Plaia Address: 2155 Grand Ave city-Mattituck st: NY zip. 11952 Building Permit* 43986 Section 107 Block: 8 Lot- 4 - WAS -WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA: Island Electrical Corp. License No: 37608-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New X Renovation 2nd Floor Hot Tub Addition Survey X Attic Garage INVENTORY Service 1 ph X Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel 200A A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures 11 Combo SD/CO Other Equipment System Size: 8.375 KW, 25- Modules: LG 335N1 C-A5, 25-Micro Inverters: Enphase IQ7PLUS-72-2-US, Enphase Combiner Box 80A w/ 10A Breakerand 2- 20A Breakers, 60A Fusible AC Disconnect, Bonding Inspector Signature Date. October 2, 2019 S.Devlin-Cert Electrical Compliance Form As ZI SS ��1 a SOUIyOIo L4 0; TOWN OF SOUTHOLD BUILDING DEPT. courm N�'' 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE INSPECTOR Daniel W Dunzik Architect 370 Burnt Hill Road r Skillman,NJ. 085558 OCT - 7 October 3, 2019 The Town of Southold 54375 NY-25 Southold,NY. 11971 Subject: Architect Statement for Solar Rooftop Installation Residence- Catherine Plaia: 2155 Grand Avenue. Mattituck,NY. 11952 Permit No.43986 - Number of Solar Panels installed: 25 modules/ 25 inverters , 8.375 KW system size Post Installation Inspection Date:8/2/19 The rooftop photovoltaic system at the above referenced residence has been observed to be installed properly in accordance with the approved plans and is certified by Daniel W Dunzik Architectural Services, P.C. to be in compliance with the minimum requirements of the Town, the 2015-International Residential Code and the 2016-New York State Uniform Code Supplement and the Provisions of ASCE 7-10. Sincerely., r a� del Do 03963" O F JQ1 Daniel W Dunzik RA LEED-AP NY.LIC.NO 039534 FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(1ST) y ------------------------------- FOUNDATION (2ND) t�2i z � o y ROUGH FRAMING& PLUMBING r INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS rn o � y �v ~ 0 z C ro� H TOWN OF.SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (63t)`765-1802Planning Board approval FAX: (631) 765-9502 �fi Survey Yg Southoldtownn . ov PERMIT NO. ® �/ Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined 20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved 20 Mail to: Disapproved a/c / Phone: Expiration 20 p Building Inspector JUL 1 1 2019 APPLICATION FOR BUILDING PERMIT DUMDDTG DEFT°. Date July 11th 2019 TMVIN OF SO dGL'-nd INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws,Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. ignature of applicant or name,if a corporation) 45 Fairchild Ave. Suite B. Plainview, NY 11803 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Cnntrartnr Name of owner of premises Catherine Plaia (As on the tax roll or latest deed) If applicant isorporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. 57578-H Plumbers License No. Electricians License No. 37608-ME Other Trade's License No. 1. Location of land on which proposed work will be done: 2155 Grand Avenue Mattituck House Number Street Hamlet County Tax Map No. 1000 Section 107 Block 8 Lot 4 y Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy 1-Family Residency b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work Installation of Solar Panels (Description) 4. Estimated Cost $28,533.96 Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO x 13. Will lot be re-graded?YES NO x Will excess fill be removed from premises?YES NO 14.Names of Owner of premises Catherine Plaia AddreSS2155 Grand Ave, Mattituck Phone No. (516)380-1006 Name of Architect Daniel Dunzik Address 370 Burnt Hill Rd,SkillmanPhone No (908)872-3664 Name of Contractor Sung Lee Address 45 Fairchild Ave. PlainvievPhone No. (631)536-4100 x.2176 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO x * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO x * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? *YES NO X * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk Sung Lee being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the Contractor (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application;' that all statements contained in this application are true to the best of his knowledge and belief;and that`the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this 11th Y of Jul 20 19 Katherine Welsb Nota is Notary Public,state of New" Signature of Applicant Reg.No.01WE6383986 aualffied in Nassau County IIA►Commission Expires December 3,2022 BUILDING DEPARTMENT- Electrical Inspector =moo G TOWN OF SOUTHOLD C x Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0963159 Telephone (631) 765-1802 - FAX ( ) 65-9502 -roger.richer O.town:southoId':nv.us APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Dater Company Name: Island Electric Cor Name: Jeffrey Marinello License No.: 37608-ME email: permitsli@momentumsolar.com Address: 45 Fairchild Avenue, Plainview NY 11803 - Phone No.: (631)536-4100 x._2176 JOB SITE INFORMATION: (All Information Required) Name: Catherine Plaia Address: 2155 Grand AyPnije_hAnttifiiCk -WX Cross Street: Woodcliff Drive _ Phone No.: (516)380-1006 Bldg.Permit#: _ _ email: Tax Map District: _ 1000- Section: 107 Block: 8 Lot:, BRIEF DESCRIPTION OF WORK(Please Print Clearly) Installation of Solar Panels: Roof Top, Grid Tied Circle Ail That Apply: Is job ready for inspection?: YES / NO Rough In Final Do you need a Temp Certificate?: YES / NO Issued On_ Temp Information: (Ail information required) Service Size 1 Ph 3 Ph Size: . . __ _ A #Meters, _ Old Meter# New Service- Fire Reconnect- Flood Reconnect- Service Reconnected -Underground - Overhead #Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: ,PAYMENT DUE WITH APPLICATION. 82-Request for Inspection Form,xls "7 qI[q Yo K Workers' CERTIFICATE OF INSURANCE COVERAGE TATECompensation Board DISABILITY AND PAID FAMILY LEAVE BENEFITS LAW PART 1.To be completed by Disability and Paid Family Leave Benefits Carrier or Licensed Insurance Agent of that Carrier 1 a Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured PRO CUSTOM SOLAR LLC (732)902-6224 DBA MOMENTUM SOLAR 45 FAIRCHILD AVE STE B PLAINVIEW,NY 11803 1 c.Federal Employer Identification Number of Insured or Social Security Work Location of Insured(Only required if coverage is specifically limited to Number certain locations in New York State,i e,a Wrap-Up Policy) 271-24-2539 2.Name and Address of Entity Requesting Proof of Coverage 3a Name of Insurance Carrier (Entity Being Listed as the Certificate Holder) New York State Insurance Fund(NYSIF) TOWN OF SOUTHOLD 53095 ROUTE 25 3b.Policy Number of Entity Listed in Box"1 a" PO BOX 1179 DBL 315268-4 SOUTHOLD,NY 11971 3c.Policy effective period 10/15/1998 to 07/01/2020 4.Policy provides the following benefits ® A Both disability and paid family leave benefits ❑ B Disability benefits only ❑ C Paid family leave benefits only 5 Policy covers ® A All of the employer's employees eligible under the NYS Disability and Paid Family Leave Benefits Law F] B Only the following class or classes of employer's employees Under penalty of perjury,I certify that I am an authorized representative or licensed agent of the insurance carrier referenced above and that the named Insured has NYS Disability and/or Paid Family Leave Benefits insurance coverage as described above Date Signed 7/11/2019 By (Signature of insurance carrier's authorized representative or NYS Licensed Insurance Agent of that insurance carrier) Telephone Number (866)697-4332 Name and Title Melissa Jensen,Director of Disability Insurance Unit IMPORTANT: If Box 4A and 5A are checked,and this form is signed by the Insurance carrier's authorized representative or NYS Licensed Insurance Agent ofthat carrier,this certificate Is COMPLETE Mall it directly to the certificate holder If Box 413,4C or 5B is checked,this certificate is NOT COMPLETE for purposes of Section 220, Subd 8 of the NYS Disability and Paid Family Leave Benefits Law It must be mailed for completion to the Workers'Compensation Board, DB Plans Acceptance Unit, PO Box 5200, Binghamton, NY 13902-5200 PART 2.To be completed by the NYS Workers'Compensation Board(Only if Box 4C or 513 of Part 1 has been checked) State of New York Workers' Compensation Board According to Information maintained by the NYS Workers'Compensation Board,the above-named employer has complied with the NYS Disability and Paid Family Leave Benefits Law with respect to all of his/her employees Date Signed By (Signature of Authorized NYS Workers'Compensation Board Employee) Telephone Number Name and Title Please Note:Only insurance carriers licensed to write NYS disability and paid family leave benefits insurance policies and NYS licensed insurance agents of those insurance carriers are authorized to issue Form DB-120 1 Insurance brokers are NOT authorized to issue this form. DB-120.1 (10-17) Certificate Number 567286 Suffolk County dept. of Labor Licensing & Consumer Affairs HOME IMPROVEMENT LICENSE Name _ SUNG LEE a Business Name PRO CUSTOM SOLAR DBA This certifies that the ° bearer is duly licensed License Number H-5757$ by the County of Suffolk Issued : 10/06/2016 Commissioner Expires : 10/01 /2020 PROCU-1 OP ID: LM AC®RO® CERTIFICATE OF LIABILITY INSURANCE DATE(M2/20 04/22/20 9 19 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Lisa MacDonald Brown&Brown Insurance NAME: 2000 Medlantic Dr.-Suite 440 a"c°Nr o E,t,732-504-2001 FAX No:732-504-2011 Mount Laurel,NJ 08054 E-MAIL Imacdonald@bbdvins.com Brian DiLuigi ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# INSURER A:Southwest Marine&General Ins INSURED Pro Custom Solar LLC INSURER B:Gotham Insurance Company 25569 dba Momentum Solar dba Momentum Home INSURERC.-United States Fire Ins Co 21113 45 Fairchild Ave.,Suite B INSURER D:Lloyd's Plainview, NY 11803 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE POLICY EFF POLICY EXP LIMBS LTR POLICY NUMBER MM/DD MMIDD A X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,00 CLAIMS-MADE XOCCUR GL201800010727 12112/2018 12/12/2079 PREMISES Ea occurrence $ 100,00 MED EXP(Anyone person) $ 5,00 PERSONAL&ADV INJURY $ 1,000,00 GEN'L AGGREGATE LIMIT APPLIES PER, GENERAL AGGREGATE $ 2,000,00 POLICY PRO- JECT LOC PRODUCTS-COMP/OP AGG $ 2,000,00 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT Ea accident $ 1,000,00 C X ANY AUTO 133-745523-3 04/21/2019 04/21/2020 BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY(Per accident) $ NON-OWNED PROPERTY DAMAGE $ X HIRED AUTOS X AUTOS Per accident $ X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 5,000,00 B EXCESS LIAR CLAIMS-MADE UM201800004884 12/1212018 12/12/2019 AGGREGATE $ 5,000,00 DED I X I RETENTION$ 10000 $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/" STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVEE.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? F-1 N/A (Mandatary In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ D Professional ANE1860007.18 12/12/2018 12/12/2019 Limit 1,000,00 CLAIMS MADE DESCRIPTION OF OPERATIONS f LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space is required) CERTIFICATE HOLDER CANCELLATION TOWNOFS SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Town of Southold THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. 53095 Middle Road Southold,NY 11971 AUTHORIZED REPRESENTATIVE ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD ZYSTOATttK Workers' CERTIFICATE OF E Compensation NYS WORKERS' COMPENSATION INSURANCE COVERAGE �ioard 1a.Legal Name Address of Insured(use street address only) 1b.Business Telephone Number of Insured CoAdvantage Resources 51,Inc.Labor Contractor,for leased workers to: (813)935-2000 Pro Custom Solar,LLC dba:Momentum Solar 1c.NYS Unemployment Insurance Employer Registration Number of insured 45 Fairchild Ave Ste B Plainview,NY 11803 1d.Federal Employer Identification Number of Insured or Social Security Work Location of Insured(Only required if coverage is specifically limited to certain Number locations in New York State,i.e.,a Wrap-Up Policy) 27-1242539 2.Name and Address of Entity Requesting Proof of Coverage(Entity Being 3a.Name of Insurance Carrier Listed as the Certificate Holder) American Zurich Insurance Company Town of Southold 3b.Policy Number of Entity Listed in Box"1 a" 53095 Middle Road WC 11-25-632-01 3c.Policy effective period Southold, NY 11971 4/1/2019 to 4/1/2020 3d.The Proprietor,Partners,or Executive Officers are included.(Only check box if all partners/officers inclued) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box"3 insures the business r ferenced above in box"la"for workers'compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy).The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". The insurance carrier must notify the above certificate holder and the Workers Compensation Board within 10 days IF a policy is canceled due to nonpayment of premiums or within 30 days IF there are reasons other than nonpayment of premiums that cancel the policy or eliminate the insured from the coverage indicated on this Certificate.(These notices may be sent by regular mail.)Otherwise,this Certificate is valid for one year after this form is approved by the insurance carrier or its licensed agent,or until the policy expiration date listed in box 3c,whichever is earlier. This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend,extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,[!case or contract Issued by a certificate holder,teh business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized prof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of pedury,I certify that I am an authorized representative or licensed agent of the insurance canter refemced above and that the named insured has the coverage as depicted on this form. Approved by: Douglas Jones (Print name of authorized representative or licensed agent of insurance carrier) Approved bv: C��,��L'J�'�� 3/25/2019 (Signature) (Date) Title: Vice President Telephone number of authorized representative or licensed agent of insurance carrier: (480951-4177 Please Note:Only insurance carriers and their licensed agents are authorized to issue Form C•105.2.Insurance brokers are NOT authorized to issue it. C-105.2(9-17) ww.vvcb.ny.gov PLAN KEY SYSTEM INFORMATION PV-1 COVER PAGE MODULE LG LG 335N1C-A5 momentum PV-1(2) COVER PAGE CONT. INVERTER ENPHASE IQ7PLUS-72-2-US SOLAR PV-2 PANEL LAYOUT RACKING ECOFASTEN ROCK-IT SYSTEM PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR PV-3 LAYOUT DETAIL SYSTEM SIZE (DC) 8.375 KW 3096SOUTH PLAINFIELD,NJ BUILDING B (732)902-6224 PV-4 ELECTRICAL STRUCTURAL LOCATION 41.002449, -72.540680, PV-5 EQUIPMENT LABELS ENGINEERING GENERAL NOTES: DANIEL W.DUNZIK RA LEED-AP LICENSE B 039534 (908)872-3664 THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS SKILLMAN w 8558LL ENGINEERING HAS SPECIFICATIONS FORD FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-10, IRC 2015 AND NEW AND LOAD CALCLUULAETIONSACHED FOR SOLAR INSTALLATION SPANS&IND YORK STATE UCS 2017 NEC 2014 AND ALL LOCAL CODES &ORDINANCES. ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A AN 18" WIDE (FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED ALONG AT LEAST LICENSED ARCHITECT,TO ALTER AN nEM IN ANY WAY. ONE SIDE OF THE ROOF ON THE SAME SIDE AS THE SOLAR EQUIPMENT OR ON ANOTHER SIDE OF THE RIDGE THAT DOES NOT HAVE SOLAR EQUIPMENT ON IT. IN ADDITION AN 36" WIDE PATHWAY(FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED FROM AT LEAST ONE EAVE. LQ ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE SOLAR EQUIPMENT. -� 1 2019 A'1p SEP 1 - � INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND NO MORE THAN 6—INCHES ABOVE THE SURFACE OF THE ROOF. , s7i'^i Y 5B'. " ', 039534 �0 WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5—PSF FOR f a PHOTOVOLTAIC AND NO MORE THAN 6—PSF FOR RESIDENTIAL SOLAR HOT WATER _ CF ,h,! \N SYSTEMS. ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT CUSTOMER INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A INFORMATION PLUMBING PERMIT AND INSPECTION. CATHERINE PLAIA—MS30379 INVERTER PLACEMENT: QI 2155 GRAND AVENUE J MATTITUCK NY 11952 SYSTEM UTILIZES "ENPHASE" MICRO—INVERTERS WITH RAPID SHUTDOWN CONTROL (516)380-1006 LOCATED ON THE BACK SIDE OF EACH MODULE. JURISTICTION:SUFFOLK BILL OF MATERIALS UTILITY:PSEGLI BUILDING REVIEW NOTE: MODULES 25 UTILITY ACCT#:9625516352 UTILITY METER#:46956054 TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE ENCLOSED DOCUMENT FOR INVERTERS 25 MINIMUM ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SPECIFIED CLAMP ASSEMBLY 45 PV SYSTEM IN THE BUILDING AND/OR RESIDENTIAL CODE OF THE STATE OF NEW YORK. THISREVIEW DOES NOT GUARANTEE COMPLIANCE OF THAT CODE. THAT COUPLING ASSEMBLY 34 RESPONSIBILITY IS GUARANTEED UNDER THE SEAL AND SIGNATURE OF THE NEW SYSTEM SIZE(DC):8.375 KW YORK LICENSED DESIGN PROFESSIONAL OF RECORD. THAT SEAL AND SIGNATURE BONDING CLIP 7 25 MODULES: ODU E SLGLG33NIC—A5 HAS BEEN INTERPRETED AS AN ATTESTATION THAT, TO THE BEST OF THE LICENSEE'S SKIRTS 9 25 INVERTERS: NV RTER :ENPHASE BELIEF AND INFORMATION,THE WORK IN DOCUMENT IS: ENPHASE COMBINER BOX 1 1. ACCURATE 40A FUSES 2 2. CONFORMS WITH GOVERNING CODES APPLICABLE AT THE TIME OF THE PROJECT INFORMATION SUBMISSION. 60A FUSIBLE AC DISCONNECT 1 3. CONFORMS WITH REASONABLE STANDARDS OF PRACTICE AND WITH VIEW TO INITIAL DATE:8/28/2019 DESIGNER:TO THE SAFEGUARDING OF LIFE, HEALTH, PROPERTY AND PUBLIC WELFARE IS THE 125A LINE TAPS 2 REV: DATE: DESIGNER: RESPONSIBILITY OF THE LICENSEE. REV: DATE: DESIGNER: COVER PAGE PV- 1 . 1 1. ALL WIND DESIGN CRITERIA ARE FOR GABLE AND HIP RESIDENTIAL ROOFS SEE ATTACHMENT SCHEDULE CONSIDERED FROM AN ANGLE OF MIN. 9.5 ° (6) TO MAX. 450 (fli) NOT TO FOR MAXIMUM CANTILEVER ❑ EXCEED 30' MEAN ROOF HEIGHT WITH A MIN " LAG BOLT(ASTE A276) COUPLING STAINLESS STEEL INTO THE RAFTER OR BLOCKING BETWEEN RAFTERS W/ MIN. CLAMP&ATTACHMENT momentum EMBEDMENT OF 3.25" SOLAR 2. THIS STRUCTURAL DESIGN REFLECTS STRUCTURAL CONNECTIONS TO THE RAFTS LG LG 335N1C-A5 EXISTING STRUCTURE ONLY. MODULE TO ROCK-IT LOADING AND SOLAR MODU 335 pWATT MODULE CERTIFICATION PER MECHANICAL LOAD TESTS IAW/ANSI UL2703 CONDUCTED 0'-0-" PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 6 3811 X 40" X 1.5 " ON BEHALF OF ECOFASTEN SOLAR BY TUV RHEELAND REFERENCE FILE 0'-13" 2— / 3096 HAMILTON BLVD.BUILDING B gSEE DATASHEETT L2-ELS150128a REV 1 16 / SOUTH PLAT 902-6 4 o7oso ( ) ® / (732)902-6224 3. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511 AND IS THE GUTV MOMENTUMSOLAR.COM CLIMATIC & GEOGRAPHIC DESIGN CRITERIA RESPONSIBILITY OF THE CONTRACTOR TO FILL ALL HOLES WATER TIGHT. STRUCTURAL TABLE R301.2 1 4. "ROCK-IT" ATTACHMENTS ARE MANUFACTURED BY ECOFASTEN SOLAR, PHOENIX, / MINIMUM 5-SPACING TO GUTTER ENGINEERING ( ) ARIZONA. AND SHALL BE INSTALLED IN STRICT COMPLIANCE WITH / DANIEL W.DUNZIK RA LEED-AP ECOFASTEN SOLAR ROCK-1T40 MOUNTING DETAIL LICENSE*039534 MANUFACTURERS PRINTED INSTRUCTIONS. / ECOFASTEN SOLAR ROCK-IT 4 0 RAIL-LESS MOUNTING (908)872-3664 GROUND SNOW LOAD(LBS/SF) 25 SYSTEM INTEGRATED WITH FLASHING,COUPLINGS 370 BURNT HILL ROAD ROCK-IT TO RAFTER ATTACHMENT SPACING SCHEDULE / AND ADJUSTABLE CLAMP ATTACHMENTS SKILLMAN,NJ 08558 SPEED (MPH) 140 �` ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& TOPOGRAPHIC EFFECTS B ULTIMATECOMPLIATTACHAENTS NCE EET TIHAT IT IS A LOCALA AND VIOLA'TATE UILDINGCODE EL DESIGN ROOF ZONE 1 ROOF ZONE 2&3 MANY PERRSSON;UNLESS ACTING UNDER THE DIRREC OF OFAW FOR SPECIAL WIND REGION NO WIND MAX.SPAN/MAX. MAX.SPAN/MAX. LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. SPEED CANTILEVER CANTILEVER WIND BORNE DEBRIS ZONE 2 (MPH) (INCHES) (INCHES) SEISMIC DESIGN CATEGORY C 115 48"O.C./16"MAX. 32"O.C./12"MAX. CLIMATE ZONE 5A 125 48"O.C./16"MAX. 32"O.C./12"MAX. FASTENER REQUIREMENTS: 130 48"O.C./16"MAX. 32"O.C./12"MAX. TOTAL ARRAY AREA=460.97 SQ FT WIND EXPOSURE CATEGORY B 140 48"O.C./16"MAX. 24"O.C./10"MAX. WIND LOAD:ASCE 30(SEE CALCULATIONS,STRUCTURAL CERTIFICATION)50 PSF MAX 150 40"O.C./16"MAX. 16"O.C./8"MTOTAL UPLIFT 50 PSF X 460.97=23048.61 LBS AX. MAXIMUM SOLAR ARRAY ELEVATION:4.25" 160 32"O.C./12"MAX. 16"O.C./8"MAX. MAXIMUM CLAMP ATTACHMENT SPACING:48" FASTENER: TABLE REFLECTS ATTACHMENT SPACINGS THAT EXCEED MANUFACTURERS LAG SCREW SPEC 203.2,8/04:(FLAT WASHERS TO BE USED WITH LAG BOLTS) SPECIFICATIONS FOR WIND LOADS AS PER ASCE 07-10. RISK CATEGORY II LAG BOLT WITHDRAWAL VALUE 5/16"DIA.,266 LB/IN X 2-INCH THREAD DEPTH: TOPOGRAPHIC EFFECTS B,C,&D AND ROOF WIND ZONES 1,2,&3. ROOF ZONES 2&3 532LB.CAP.EACH ARE WITHIN 48"OF ANY OUTER EDGE,HIP, RIDGE,OR GUTTER LINE FOR STRUCTURES MINIMUM NUMBER OF LAG BOLTS REQUIRED:23048.61 LBS/532 LBS/LAG BOLT=44 COUPLING CLAM MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS"X"USE 48"MAX ALLOWED AS 30'-0" OR LESS MEAN ROOF HEIGHT. PER SCHEDULE SOLID BLOCK IN GUTTER GUTTER STRUCTURAL STATEMENT: CUSTOMER BETWEEN JOISTS p ® ® ® INFORMATION AS REQUIRED N co THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE CATHERINE PLATA-M530379 co w w NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE 2155 GRAND AVENUE Y ® © © ® w SYSTEM INCLUDING UPLIFT&SHEAR.EXISTING RAFTER MATTITUCK NY 11952 �Q ® SIZES &DIMENSIONS CONFIRM TO IRC-2015 TABLE (516)380-1006 © ® RIDGE RIDGE 'ECOFASTEN'ROCK-IT C=7 R802.5(1)-RAFTER SPANS. ATACHMENT SYSTEM © ® (2) Q® © ® MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED IURISTICTION:SUFFOLK 'ECOFASTEN'EF-44R-SS-NDD 'sip UTILITY:PSEGLI NEW YORK STATE CODE REQUIREMENTS FOR THE DESIGN ATTACHMENT AND BASHING W w UTILITY ACCT#:9625516352 SOLAR MODULE Y CRITERIA OF THE TOWN. UTILITY METER#:46956054 8 XHDF5 FASTENERS TO DECK EXISTING ROOF MEMBRANE, ® © m PLYWOOD DECK,AND PV SYSTEM 'ECOFASTEN'SKIRT RAFTER 101 ® GUTTER ® GUTTER SYSTEM SIZE(DC):8.375 KW ROOF WIND ZONES AS PER IRC R301.2(7) 25 MODULES:LG LG 33SN1C-A5 ROOF ZONES 2&3 ARE 48"FROM OUTTER ROOF EDGES, 25 INVERTERS:ENPHASE RIDGES,HIPS, RAKES,AND GUTTER EDGES FOR STRUCTURES IQ7PLUS-72-2-US BELOW 30'-0"MEAN ROOF HT. PROJECT INFORMATION ALL COMPONENTS SHALL BE AS MANUFACTURED BY'ECOFASTEN Saw AND INITIAL DATE:8/28/2019 DESIGNER:TO INSTALLED IN STRICT COMPLIANCE HATH MANUFACTURERS PRINTED SPECIFICATIONS. REV: DATE: DESIGNER: REV: DATE: DESIGNER: COVER PAGE PV- 1 ( 2) . 1 SCALE: 1/8'° = 1'-0" ROOF MODULE COUNT TILT AZIMUTH SHADING O R1 21 18° 249° 85% MSP R2 2 18° 156° 93% 0 momentum FIRE SETBACK ELECTRICAL EQUIPMENT R3 2 18° 336' 87% SOLAR (18"VENTILATION, 36" ROOF ACCESS) PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR (TYP) 3096 HAMILTON BLVD.BUILDING B SOUTH PLAINFIELD,NJ 07080 Q (732)902-6224 Q MOMENTUMSOLAR.COM STRUCTURAL ENGINEERING Q Q DANIEL W.DUNZIK RA LEED-AP Qa LICENSE# 34 (909)872-3664 370 BURNT HILL ROAD ELECTRICAL EQUIPMENT W o W �Q ENGI ARIwLassa -� ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& Ur ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE WARNING THAT IT IS A VIOLATION OF THE LAW FOR CB V ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY 0 0 4 o Q Q Q a Q R1 — 0 0 DRIVEWAY G1 D Z v 0 o R3 m z c M CUSTOMER o R2 o INFORMATION -zj CATHERINE PLAIA-MS30379 O 2155 GRAND AVENUE ;a MATTITUCK NY 11952 M (516)380-1006 zSYMBOL LEGEND JURISTICTION:SUFFOLK n UTILITY:PSEGLI ® Uim MSP MAIN SERVICE PANEL ® CHIMNEY UTILITY ACCT#:9625516352 UTILITY METER#:46956054 R1 O SP SUB-PANEL SKYLIGHT PV SYSTEM 0 OM UTILITY METER ® VENT SYSTEM SIZE(DC):8.375 KW t o o AC AC DISCONNECT 0 PIPE VENT 25 MODULES: LG LG 335NiC-A5 j DISC 25 INVERTERS: ENPHASE IQ7PLUS-72-2-US UDC UTILITY DISCONNECT FAN 0 GROUND ACCESS O (TYP) LC LOAD CENTER SATELLITE DISH O PR03ECTINFORMATION N3R NEMA 3R BOX W/ENVOY-S ® FIRE SETBACKS INITIAL DATE:8/28/2019 DESIGNER:TO REV: DATE: DESIGNER: O O CB COMBINER BOX GROUND ACCESS REV: DATE: DESIGNER: SOLAR INSTALLER NOTES: PF PERFORMANCE METER -► PITCH DIRECTION PANEL LAYOUT NO ADDITIONAL STRUCTURAL SUPPORT REQUIRE® MODULE PV-2■ l R1 -ARRAY 1 LAYOUT DETAIL R2 - ARRAY 2 LAYOUT DETAIL SCALE: 3/32" = 1'-0" SCALE: 1/8" = 1'-0" TILT: 18° TILT: 18° momentum AZIMUTH: 249° AZIMUTH: 156° SOLAR SHADING: 85% SHADING: 93% PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD.BUILDING B SOUTH PLAINFIELD,N]07080 (732)902-6224 MOMENTUMSOLAR COM STRUCTURAL ENGINEERING [EL W.DUNZIK RA LEED-AP CENSE F 558 )EIGINEERING 8872-3664 IURNT HILL RDA MAN W E LETTER ATTACHED HAS SPECIFICATIONS FOR WIND10 + D LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS ACHMENTS TO MEET LOCAL AND STATE BUILDING CODE OMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR Y PERSONUNLESS ACTING UNDER THE I ^ 8 ���� �' j I/�/ I { I g• �i) � I 5 I I I +�/ ENSED ARCHITECT,TO ALTER AN ITEM INDIRECTION ANY AY OF A LI {t illli_ SOLAR INSTALLER NOTES: SOLAR INSTALLER NOTES: NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED R3 - ARRAY 3 LAYOUT DETAIL CUSTOMER SCALE: 3/16" = 1'-0" INFORMATION TILT: 18* CATHERINE PLAIA-MS30379 AZIMUTH: 336° 2155 GRAND AVENUE SHADING: 87% MATTITUCK NY 11952 (516)380-1006 RISTICTION:SUFFOLK TILITY:PSEGLI Fi 'T� � TILITY ACCT#:9625516352 ' ILITY METER#:46956054 I I 1 I PV SYSTEM YSTEM SIZE(DC):8.375 KW faMODULES:LG LG 335NiC-A5 INVERTERS: ENPHASE 7PLUS-72-2-US I PR03ECT INFORMATION Ll I ITIAL DATE:8/28/2019 DESIGNER:TO EV. DATE: DESIGNER: +: DATE, DESIGNER: SOLAR INSTALLER NOTES: LAYOUT DETAIL NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED PV-3■ l 25 LG LG 335N1C-A5 335W MODULES PAIRED WITH momentum 25 ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS SOLAR BRANCH CIRCUIT PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 13 MICRO-INVERTERS 3096 HAMILTON BLVD.BUILDING B BRANCH CIRCUIT B EXISTING SQUARE D 200A SOUTH PLAINFIELD,NJ 07080 12 MICRO-INVERTERS MAIN SERVICE PANEL 240 V (732)902-6224 MOMENTUMSOLAR.COM MAIN BREAKER:200A STRUCTURAL ENPHASE 80A AC ENGINEERING COMBINER BOX DANIEL W DUNZIK RA LEED-AP LICENSE#039534 W/ENVOY IQ 200A (908)872-364 BURNT HILL ROAD GRID SKILLMAN,NJ 08558 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND ~- AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& 8 ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR g ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A 40A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. ELECTRICIAN ROOF 10A BREAKER 89L AC POWER UTILITY JEFFFRREEY�MOM SOLAR ARINELLO DBA MOMENTUM SOLAR JUNCTION (ENVOY) DISCONNECT =GROUND METER 3096 HAMILTON BLVD.BUILDING B BOX 20A BREAKER(A) SOUTH PLAINFIELD,NJ 07080 TERMINATION CAP 1 2A-B 20A BREAKER(B)3 (732)902-6224 INSTALLED ON END OF CABLE ELECTRICAL NOTES: 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2014 ARTICLE 310 10.SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED CUSTOMER 1.ALL CALCULATIONS FOR VOC,VMAX, IMP AND ISC HAVE BEEN 6.ALL EQUIPMENT INSTALLED IS RATED AT 75°C UNLESS NOTED LABELING AS PER 690.56(C).AC VOLTAGE AND SYSTEM OPERATING CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON 7. INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM CURRENT SHALL BE PROVIDED AS PER 690.52. INFORMATION ASHRAE 2%HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. EQUIPMENT DATA SHEET 11.CONDUCTORS IN CONDUIT ARE AC CONDUCTORS-BRANCH 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 8. GROUNDING CONDUCTOR RUN WITH PHASE CONDUCTOR IN CIRCUITS AND NOT PV SOURCE CIRCUITS 690.6. CATHERINE PLAIA-MS30379 PARAGRAPH C). THE SAME CONDUIT. 12.ALL GROUNDING SHALL COMPLY WITH 690.47(A)IN THAT THE AC 2155 GRAND AVENUE 3. THIS SYSTEM COMPLIES WITH NEC 2014 9. SYSTEM IS CONSIDERED AN AC MODULE SYSTEM.NO DC MODULES SHALL COMPLY WITH 250.64. MATTITUCK NY 11952 4. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST CONDUCTORS ARE PRESENT IN CONDUIT,COMBINER,JUNCTION 13.NO TERMINALS WILL BE ENERGIZED IN THE OPEN,POSITION IN THIS (516)380-1006 BRANCH CIRCUIT IN SYSTEM.OTHER BRANCH CIRCUITS WILL HAVE LOWER BOX, DISCONNECT.AND COMPILES WITH 690.6-NO DC. AC MODULE SYSTEM 690.6,690.17. DESIGN CURRENT THAN THE ONE SHOWN. DISCONNECT AND ASSOCIATED DC CABLING ARE REQUIRED. 14.WHERE APPLICABLE, INTERCONNECTION SHALL COMPLY WITH JURISTICTION:SUFFOLK 705.12(D)(3),705.12(13)(2)(3)(B),705.12(A)AS PERMITTED BY 230.86(6) UTILITY:PSEGLI UTILITY ACCT#:9625516352 UTILITY METER#:46956054 PV SYSTEM SYSTEM SIZE(DC):8.375 KW 25 MODULES:LG LG 335N1C-A5 25 INVERTERS: ENPHASE IQ7PLUS-72-2-US Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC(A) Correction Current(A) Size Type PR03ECT INFORMATION 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 13 1.21 1.25 19.66 12 AWG Trunk Cable I MAL DATE:8/28/2019 DESIGNER:TO R DATE: DESIGNER: 2A V, PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 13 1.21 1.25 19.66 08 AWG THWN-2 DATE: DESIGNER: 2B 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 12 1.21 1.25 18.15 08 AWG THWN-2 ELECTRICAL 3 1" PVC 3 08 AWG THWN-2 75°C 50 0.96 1 48.00 25 1.21 1.25 37.81 08 AWG THWN-2 4 1" PVC 3 06 AWG THWN-2 75°C 65 0.96 1 62.40 25 1.21 1.25 37.81 08 AWG THWN-2 TAG LABEL QUANTITY LOCATION NOTE EXAMPLES ARNING1 AT EVERY SEPARATION BY O A 12 DC CONDUITS ENCLOSURES/WALLS/ 0 momentum PARTITIONS/CEILINGS/FLOORS PHOTOVOLTAIC POWER SOURCE OR NO MORE THAN 10' ;,:.: SOLAR _ PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR A WARNING • • • - • © 3096 HAMILTON BLVD.BUILDING B - --� SOUTH PLAINFIELD,NJ 07080 © EQUIPPED •• 1 COMBINER BOX 1 AT ANY JUNCTION BOX OR DC (732)902-6224 MOMENTUMSOLAR.COM RAPID �• COMBINER IF USED PHOTOVOLTAIC POWER STRUCTURAL ENGINEERING O - DANIEL W.DUNZIK RA LEED-AP LICENSE#039534 (908)872-3664 370 BURNT HILL ROAD SKILLMAN,NJ 08558 A . RNING _ ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A © ELECTRICAL SHOCK 1 JUNCTION BOX 1 AT ANY JUNCTION BOX OR DC , • LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. • • • COMBINER IF USED AC NNEJ, TERMINALS ON BOTH LINE AND ••D SIDES MAY BE ENERGIZED IN THE OPEN P• • PHOTOVOLTAIC AC DI • A WARNING P,407"-.'0'TAlC SYSTEM OPERATING CURRENT 1 OF EACH AT FUSED AC 0 ELECTRICAL SH OCK .• DISCONNECT • • • 1 AC DISCONNECT COMPLETE VOLTAGE AND OPERATION • 240 TERMINALS ON •TH LINE AND CURRENT VALUES ON LOAD SIDES MAY BE DISCONNECT LABEL IN THE •• •• • i CUSTOMER INFORMATION • BREAKER AWARNING —� CATHERINE PLAIA- MS30379 • 2155 GRAND AVENUE DE DUAL POWER • _ • _ 1 MAIN DISCONNECT 1 OF EACH AT BUILDING MAIN MATTITUCK NY 11952 L l PANEL DISCONNECT PANEL f O (516)380-1006 • • SOURCE IS PHOTOVOLTAIC SYSTEMc,m.a r i JURISTICTION:SUFFOLK Y •.e:P- ' UTILITY: PSEGLI -- -- UTILITY ACCT#: 9625516352 UTILITY METER#:46956054 AWARNING PV SYSTEM O DUAL POWER SOURCE 1 UTILITY METER 1 AT UTILITY METER �E INFORMATION SECOND SOURCE IS PHOTOVOLTAIC SYSTEM SIZE (DC ):8.375 KW MEL 25 MODULES: LG LG 335N1C-A5 ' ` 25 INVERTERS: ENPHASE MEANS OF INTERCONNECTION LOCATION NOTE IQ7PLU5-72-2-US 4 � I MAIN SERVICE O j PROTECT INFORMATION © BACKFEED BREAKER 1 PANEL OR PER 705.12(D)(2)(3)(c) \ DISCONNECT INITIAL DATE:8/28/2019 DESIGNER:TO REV: DATE: DESIGNER: G REV: DATE: DESIGNER: QH LINE SIDE TAP 1 M PANEL ORAIN E PER 705.12(D)(2)(3)(c) G DISCONNECT EQUIPMENT LABELS PV- 5 . 1 The new EcoX is an innovative, rail-less racking system,proven to organize the installation process. The flexible design _ _- offers a clean aesthetic, - simplified logistics,and delivers ECO)< a higher quality installation at a lower cost per watt. Aesthetic Design Cable Management A wide range of adjustment makes it easy to install a Whether installing with Microinverters,Power straight,level system. Components are designed to Optimizers,or String Inverters,EcoX provides wire blend into the array,and the aesthetic skirt creates management provisions to both prep the modules,and a finished look. Alternatively,a skirt Free option is to route homerun or trunk cables throughout the array available to provide a more traditional look. l-- — —— -- UwOut --v-a Flexible System Design Single Point Grounding The EcoX Estimator is a powerful racking system EcoX and approved modules create a continuously design tool.The user inputs all site conditions and bonded system The Installer can connect a finished can layout multiple rooFsurlaces. The EcoX Estimator anay to ground with a single bonding lug. outputs a site specific design package with engineering specs and bill of materials. ' Technical Specifications Racking components Aluminum,stainless hardware,dark Fast. Simple. Supported. Materials bronze anodized upper ackpe,mill finish lower surraces Flashings:Aluminum,black powder coated finish Modules drop In From above Universal components mount to The Ecolibrium Reid support team Grounding/Bonding Validation UL2703-see installation manual for specific module approvals and there is never a need to standard framed modules With offers on-site installation training --- ---— --- -- - reach over or walk on modules a single socket size and a wide and ongoing technical support. Fire Resistance Validation UL27O3-Class A,Type 1 and Type 2 modules Pre-assembled components range of adjustment,it is quick And From project planning to ----- -- - ----"-- - and quick connections make and easy to install any array logistics to Installation,we are Mechanical Load Validation I UL2703-see installation manual For specific module approvals EcoX easy to install with a clean,finished look. dedicated to customer service. Flashing Validation ICC-ES AC286/UL441 Rain Test For Roof Flashing Adlustabi6ty 1"vertical range,3 5"North/South range, connect anywhere in East/West direction Warranty — 15 years C_�N-1`.t — salespecdibriumsdacrom I US 740-249-1877 www.erolibnumsolarcom Ecolibrium Solar salesiAecolibnumsolarcom US 740-249-1877 wwwecolibnumsolarcom GiW iumSolar LG NeON z - Mechanical Properties Electrical Properties(STC*) Cells 6x10 Module L633SNiC•A5 LG33MJC-AS LG325N1C-AS Cee vendor LG _ Manmumyoanr(Finan) 335 330 325 Cee Type Monacrysta8ne/N _- MPp Vnitage(Vmpp) 341 33.7 333 CeU Dimensions 1617.167 7 m_m/6lnches MPP Current(Impp) 9.83 98 9.77 .of Busbar _ 12(Multi WI.W bar) -- - Open Gcuh Voltage(Voc) 41.0 40.9 40.8 Dimensions(L x W x H) 1686 x 1016 x 40 mm Shore Grwie[umrwt(Isc) 70.49 WAS 70.41 .-- 6 40x 1571ncfi Madukwy -.-.. 19b 19.3 lA0 ront Ftoad 6000000 pePa ObngT mpe at a _gp_.gp __. -.-.- ad 5400Pa Maximm System V hage _-- 10 .00 w6gh,Weight 1Bkg Max m5e Fuse Raba 20 Craraactor Type III P Tolerance(%) O- llrxetiorr -c Box P6B with 3Bypass Diodes r n.,.nl.x rnmema�r mweaxa u,[now�tx•rwax r".o.renw zs AM1s _- — - -- ynapowa wNm nmesaM as A•trmWNptG HerbmoYhtlewaNYrseveaas C bks 1000 mm Zea ra m..•n..,mml r.mx.y,r�mwm+YrelYrm r°taoowAaiY:.oA WOTrunivromm Ttmpered Gkm An. F me Amd ed Ala mi Electrical Properties(NOCTb) Certifications and Warranty Moduk Lfi)35N1C-A.S LG3.901MGA5 LG325N7[-AS Cerbfintbna rC61215,IEC61730-1/-2 _Muim_uln Power(Pmxx) 247 _ 243 240 A 1703 MPP Voka9e_(Vmpp) 315 31.2 30.8 ,,, F{62716(AAm_-_ - - _ urte_nt(Impp) _ 793 __7.81 77B LG NeON381 i ��� K61701( tmrmsrontest) MPP[ monia mrrosmn te_s_t) O r�I Crcwt vokage Noc) 392 38 1 380 1509001 start C4cuh Cunem(kc) 9A4 8.41 838 Mnduk Fin Ptrfantalsy(11511) Types "__ •Yocr(Nv.n.lap.,°moca+uspr.Ww.s.oeoown.•..,roYm.e,osm..eocwYd.e�atmf. Fin Rating(CANADA) Class C(ULC/ORD C1703) ihoductwarra[tty 12 years LG's new module,LG NeCINTM 2,adopts Cello technology Output warrantyofs[vlinear warranty- DkrAnW rK(m7n/n) Cello technology replaces 3 busbars with 12 thin wires +,term +>-nAr..Mey,�o,.x.mwaao.e.aan,a;;syaa°watt 60 ee ll to enhance power output and reliability LG NeONTM 2 DVE pOs C E 7 demonstrates LG's efforts to Increase customer's values LTJ 0 beyond efficiency.It features enhanced warranty,durability, Intik Temperature Characteristics performance NOR 45Y3C under real environment,and aesthetic _-_-. �•• ..• d., ..-.--- design suitable for roofs. Pmpp - -0.77%rC Voc -0.27%C 0.03%rc - ........- .�... Characteristic Curves Enhanced Performance Warranty �t High Power Output - LG WOW-2 has an enhanced performance warranty Compared with previals models the I C,Nee N"i The annual degradation has fallen from-0 6%/yr to has been designed to significerdy enhance its output -0.55%/yr.Even after 25 years,the cell guarantees 1 2%p efficiency thereby making it efficient even in limited space. ` more output than the previous LG NeOMo 2 Aesthetic Roof Outstanding Durability ---- R LG NeONn 2 has been designed with aesthetics in mind, ® With its newly reinforced frame design,LG has extended thinner wires that appear all black at a distance the wamanry of the LG NeW"2 for an additional r s o s x n w ss < The product may help increase the value of IN 2 years.Additionally,LG NeO"2 can erdum a hont a property with its modem design load up to 6000 Pa,and a rear load up to 5400 Pa. Iz Better Performance on a Sumy Day ADouble-Sided Ceti Structure g LG NeONn'2 now performs Bette on sunrry days[hank I :. cell use e rear of the red in LG NeON'"2 witl contribute to Its mV-.d temperature mefficlaxy e generation,just 6's the frust the light bean reflected hon the rear of the module is reabsorbed to generate a great a—ra of additional power. Q)L - G Npnn Amerka solar Busxen Tean Prodr2�'srffiianmsubjectmdwrge widlosrtwtke tG Bctmrvrs usA lrc -i❑N LMrimd 1000sy1an A-E-*—dCidfs,N107632 27I Airout LG Eketronks C,Wgk02017LGE3eamnxs AtldgMsreserwd Mm axon lwaB�uriae - Caroxtlssaiar@4emm 01101/20n LG Ekctrunes is a glbal payer who ha Dem mmmtted to uparding 4s capacity.based on sal r ene gy bm�ress m its future growth enyne We embarked on a soW ever h www.Ig .r.,.min a gy mune restw< qag W in 1985.suppoir fvUlGrxagsrNrapefeluinansUS N,,Oq(,LCIdr,ijk aM rrlueriakNWON).wk1-1,1y Need hk dst Moro,the Wdo the mrim[M20/a+IMtware.xpwud 32 couttrx:s n Ne nallurx9 2 years,[hneNtn.In 2013,lG NeON'"(Pevousb known a Mario%°WON)wan 7nterspW AWerC,which pawed LG rs the kadee of inn,warxm in tIe Industry Data Sheet Enphase IQ 7 and IQ 7+Microinverters Enphase Microinverters Region AMERICAS INPUT DATA(DC) IQ7-60-2-US I07PLUS-72-2-US Commonly used module pairings' 235W 350W. 235W-440W+ Module compatibility 60cellPV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60V Peak power tracking voltage 27V 37V 27V 45V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V r 48V 22 V/60V Max DC short circuit current(module Ise) 15 A 15 A Enphase The high-powered Smart grid-ready Overvoltage class OC port u 11 DC port backfeed current 0 A 0 A "and Enphase IQ 7+Micro" PV array configuration 1 x 1 ungrounded array;No additional DC side protection required, Q7 and IQ 7+ dramatically simplify the installation process while AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverti r Microinverters Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA IQ7+Microinvertersinte rate with the Enphase Nominal(LL)vohage/range' 240V/ 208V/ 240V/ 208V/ 9 P 211-264 V 183-229 V 211-264 V 183-229 V IQ Envoy'",Enphase IQ Battery'",and the Enphase Maximum continuous output current 1 0 A(240V) 1.15 A(208V) 1 21 A(240 V) 1.39 A(208 V) Enlighten"monitoring and analysis software. Exton edfrequeal ny 60 6 6D 6 Extended frequency range 47 68 Hz 47 68 Hz IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit- 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) standards set forth by previous generations and Overvoltage class AC port III III undergo over a million hours of power-on testing, AC port backfeed torrent o A o A Power factor setting 1 0 10 enabling Enphase to provide an industry-leading Power factor(adjustable) 0 BS leading 0 85 lagging 0.85 lead o es lagging warranty of up to 25 years. EFFICIENCY @240 v @toe v @240 v @toe v Peak efficiency 97.6% 976% 975% 973% CEC weighted efficiency 97.0% 970% 97.0% 97.0% MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connector type(IQ7-60-2 US S IQ7PLUS-72 2-US) MC4(or Amphenol H4 UTx with additional Q DCC-5 adapter) Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) • Lightweight and simple Weight 1.08 kg(2.381bs) • Easter Installation with Improved,lighter two-wire cabling Cooling Natural convection No fans • Built-in rapid shutdown compliant(NEC 2014 B 2017) Approved for wet locations yes Pollution degree PD3 Productive and Reliable Enclosure Class II double insulated,corrosion resistant polymeric enclosure Environmental category/Uv exposure rating NEMA Type 6/outdoor •Optimized for high powered 60celland 72-cell'modules FEATURES • More than a million hours of testing Communication Power Line Communication(PLC) •Class 11 double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase 10 Envoy •UL listed Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load break disconnect required by NEC 690. Smart Grid Read Compliance CA Rule 21(UL 1741 SA) Y UL 621091,UL1741/IEEE1547,FCC Part 15 Class 8,ICES 0003 Class B. CAN/CSA C22.2 NO.107.101 • Complies with advanced grid support,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014and frequency fide-through requirements NEC 2017 section69012 and C2212015 Rule 64-218 Rapid Shutdown of PV Systems,for AC • Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions grid requirements •Configurable for varying grid profiles • Meets CA Rule 21(UL 1741-SA) UThe 10 7.Micro is required to support 72 cell modules 1Na enforced DC/AC ratio See the compWibthly calculator a1 htipy(7enohase c i n ttalsu monLmodule compatibility2.Nominal voltage range can be extended beyond nominal if required by the utikty. 3.Limits may vary Refer to local requirements to define the number of microinveners per branch In your area. To learn more about Enphase offerings,visit enphase.com v ENP HAS E. To learn more about Enphase offerings,visit enphase.com v ENP HAS E. 92019 Enphase Energy All rights reserved NI vedemerks or Wands used are the properly of Enii Energy,Ine 2019-3-26 � Daniel W. Dunzik Architect LEED-AP Daniel W. Dunzik Architect LEED-AP 370 Burnt Hill Rd.Skillman,NJ.08558 908-872-3664 370 Burnt Hill Rd.Skillman,NJ.08558 908-872-3664 Studiogdesign@comcast.net Studiogdesigns@comcast.net July 5,2019 3.Solar modules shall be UL-1703 rated. Refer to manufacturers specifications sheets. Mattituck,NY. 4.Positive drainage of the system shall be so as not to void the existing roof warrantee. Attn:Construction Official 5.2017 New York State Uniform Code,the 2015 International Residential Code,2ND Printing, Re:Proposed Photovoltaic Solar Panel Installation as amended by the 2017 New York State Uniform Code Supplement,ASCE-7-10,2014 Catherine Plaia National Electric Code,All Local Governing County and Municipal Ordinances adopted by 2155 Grand Ave. reference or enacted by law. Mattituck,NY. 11952 Dear Plan Reviewer: Certification:I have reviewed the engineering testing reports for the racking and attachments to be used on this project and I certify that the products are capable of supporting the code required loads and are suitable for this installation when installed in strict compliance with the If you have any questions relating to this matter,please contact me at your earliest manufacturers printed instructions. convenience.Thank you. Regarding the solar panel array installation on the above referenced project please note that an inspection was performed,and analysis of the existing structure was conducted.There is adequate structural capacity for the installation of the array with the followingPn�tO�3� �i �° C recommendations: l�� C-> �„e�w o� B P.# 1.The array will be installed on the existing roof.The roof is constructed of 2"x6"wood rafters Q� P s�-- ���� C�C�, DATF: ` @ 16"O.C.spanning I P with 1"x6"T&G sheathing.The new array(See Site map by 6� l� contractor)will add 2.63 Lb./Sf overall to the roof.No additional structure supportq is required t�.ra ��� F BY: / 4 I NO IFY F BUILDING D PARTitiiENT AT for the existing roof structure. - F�'� 765-1802 8 Abri TO 4 PM FOR THE 2.The system shall be secured to the roof using the"Ecofasten Solar""Rock-IT"0 attachment =' = FOLLOWING INSPECTIONS: system.The installation shall be in strict compliance with manufacturers printed instructions. . 039533() 1. FOUNDATION - TWO REQUIRED The attachment system shall be UL 1703 approved tested.The attachments shall be min.5/16" Q� N �j FOR POURED CONCRETE x 4"long stainless-steel lags with a min.embedment of 3"into the rafters.Attachments shall be 2. ROUGH - FRAMING & PLUMBING @ 48"o.c.Max.in roof wind zone 1 and @ 24"o.c.Max.in roof wind zone 2 and 3 lags to Daniel W.Dunzik,RA.LEED-AP g. INSULATION alternate rafters. Provide 6 mil.vapor barrier between dissimilar metals.Provide water tight NY. Lic.No.039534 4. FINAL - CONSTRUCTION MUST gasket and sealant at all penetrations. Attachments shall follow panel rows as specified by the BE, COMPLETE FOR C 0. system manufacturer's installation manual.The panel angle shall match the roof slope. ALL CONSTRUCTION SHALL MEET THE Structural Design Loads per ASCE 7-10 REQUIREMENTS OF THE CODES OF NEW -Dead Loads= 10 psf(+2.6psf,New Solar Panels)= 12.6 psf-Live Load=25psf COMPLY WITH ALL CODES OF YORK STATE. NOT RESPONSIBLE FOR Total dead weight on attachment=18Lb.Max. NEW YORK STATE & TOWN CODES DESIGN OR CONSTRUCTION ERRORS. Ch.30 Wind Loads Components and Cladding AS REQUIRED A windloads=140 mph Exposure B zone 1=+/-31.4 psf.,Zone 2&3=+/-77.7psf. Area of Panels largest array=507.64sf I - Tributary area panels/attachment max.507.64sf/63n.= 8sf. Min Number of Attachments=63. Wind pressure 31.4 x Area 507.64/63 No.Attachments=398 TABLE 10.3.1 NDS Pull out strength of 5/16"x4"lags in rafter=W'=WxCdxCt=2661bs/in D TOWN TRUSTEES embedment x 3"embedment=798 xl.6Cd x1.00t=1,276 Lbs Max.>398lbs/attachment OK z ate''_ PLAN KEY SYSTEM INFORMATION PV-1 COVER PAGE MODULE LG LG 335N1C-A5 momentum PV-1(2) COVER PAGE CONT. INVERTER ENPHASE IQ7PLUS-72-2-US SOLAR PV-2 PANEL LAYOUT RACKING ECOFASTEN ROCK-IT SYSTEM PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD.BUILDING B PV-3 LAYOUT DETAIL SYSTEM SIZE (DC) 8.71 KW SOUTH PLAINFIELD,NJ 07080 PV-4 ELECTRICAL (732)902-6224STRUCTURAL LOCATION 41.002449, -72.540680, PV-5 EQUIPMENT LABELS ENGINEERING GENERAL NOTES: DANIEL W.DUNZIK RA LEED-AP LICENSE n 039534 (908)872-3664 THIS PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DESIGN STANDARDS 370 BURNT N]85558AD FOR BUILDING AND OTHER STRUCTURES OF THE ASCE 7-10, IRC 2015 AND NEW ENGINEERING NDL AO CALCCuunoNS FOR SSSO R INSTALLATION SPANS&AS SPECIFICATIONS FOR IND YORK STATE UCS 2017 NEC 2014 AND ALL LOCAL CODES &ORDINANCES. ATTACHMENTS WARNING LOCALA AND STATE BUILDINGFTCODE HEL i COMPLIANCE.WARNING THAT 1T IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. AN 18" WIDE (FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED ALONG AT LEAST ONE SIDE OF THE ROOF ON THE SAME SIDE AS THE SOLAR EQUIPMENT OR ON ANOTHER SIDE OF THE RIDGE THAT DOES NOT HAVE SOLAR EQUIPMENT ON IT. IN ADDITION AN 36" WIDE PATHWAY(FREE OF SOLAR EQUIPMENT) SHALL BE PROVIDED \c��ERED FROM AT LEAST ONE EAVE. ROOF SHALL HAVE NO MORE THAN TWO LAYERS OF COVERING IN ADDITION TO THE !"l C� SOLAR EQUIPMENT. INSTALLATION OF SOLAR EQUIPMENT SHALL BE FLUSH MOUNTED, PARALLEL TO AND �( L NO MORE THAN 6-INCHES ABOVE THE SURFACE OF THE ROOF. � "=3 j, fi �_9s34 WEIGHT OF THE INSTALLED SYSTEM SHALL NOT EXCEED MORE THAN 5-PSF FOR �� � .(`-' PHOTOVOLTAIC AND NO MORE THAN 6-PSF FOR RESIDENTIAL SOLAR HOT WATER SYSTEMS. ANY PLUMBING VENTS ARE NOT TO BE CUT OR COVERED FOR SOLAR EQUIPMENT CUSTOMER INSTALLATION. ANY RELOCATION OR MODIFICATION OF THE VENT REQUIRES A INFORMATION PLUMBING PERMIT AND INSPECTION. CATHERINE PLAIA-MS30379 INVERTER PLACEMENT: 2155 GRAND AVE 952 MATTITUCK NY 11952 (516)380-1006 SYSTEM UTILIZES "ENPHASE" MICRO-INVERTERS WITH RAPID SHUTDOWN CONTROL LOCATED ON THE BACK SIDE OF EACH MODULE. JURISTICTION:SUFFOLK BILL OF MATERIALS UTILITY:PSEGLI BUILDING REVIEW NOTE: MODULES 26 UTILITY ACCT#:9625516352 UTILITY METER#:46956054 TOWN BUILDING PLANS EXAMINER HAS RECEIVED THE ENCLOSED DOCUMENT FOR INVERTERS 26 MINIMUM ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS OF THE TOWN AS SPECIFIED CLAMP ASSEMBLY 45 PV SYSTEM IN THE BUILDING AND/OR RESIDENTIAL CODE OF THE STATE OF NEW YORK. INFORMATION THISREVIEW DOES NOT GUARANTEE COMPLIANCE OF THAT CODE. THAT COUPLING ASSEMBLY 34 SYSTEM SIZE(DC):8.71 KW RESPONSIBILITY IS GUARANTEED UNDER THE SEAL AND SIGNATURE OF THE NEW YORK LICENSED DESIGN PROFESSIONAL OF RECORD. THAT SEAL AND SIGNATURE BONDING CLIP 7 26 MODULES:LG LG 335N1C-A5 HAS BEEN INTERPRETED AS AN ATTESTATION THAT, TO THE BEST OF THE LICENSEE'S SKIRTS 9 IQ INVERTERS: ENPHASE 7PLUS-72-2-US BELIEF AND INFORMATION,THE WORK IN DOCUMENT IS: ENPHASE COMBINER BOX 1 1. ACCURATE 40A FUSES 2 2. CONFORMS WITH GOVERNING CODES APPLICABLE AT THE TIME OF THE PROJECT INFORMATION SUBMISSION. 60A FUSIBLE AC DISCONNECT 1 3. CONFORMS WITH REASONABLE STANDARDS OF PRACTICE AND WITH VIEW TO INITIAL DATE:7/10/2019 DESIGNER:TO THE SAFEGUARDING OF LIFE, HEALTH, PROPERTY AND PUBLIC WELFARE IS THE 125A LINE TAPS 2 REV: DATE: DESIGNER: RESPONSIBILITY OF THE LICENSEE. REV: DATE: DESIGNER: COVER PAGE Pv- 1 1. ALL WIND DESIGN CRITERIA ARE FOR GABLE AND HIP RESIDENTIAL ROOFS SEE ATTACHMENT SCHEDULE CONSIDERED FROM AN ANGLE OF MIN. 9.5 ° (?f)TO MAX. 45° (fl) NOT TO FOR MAXIMUM CANTILEVER ElEXCEED 30' MEAN ROOF HEIGHT WITH A MIN 51g" LAG BOLT(ASTE A276) COUPLING STAINLESS STEEL INTO THE RAFTER OR BLOCKING BETWEEN RAFTERS W/ MIN. ATTACHMENT EMBEDMENT OF 3.25" 2. THIS STRUCTURAL DESIGN REFLECTS STRUCTURAL CONNECTIONS TO THE RAFTS LG LG 335N1C-A5 EXISTING STRUCTURE ONLY. MODULE TO ROCK-IT LOADING AND SOLAR MODU� 335 WATT MODULE CERTIFICATION PER MECHANICAL LOAD TESTS IAW/ANSI UL2703 CONDUCTED 0'-0-" — PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 6 38" X 40" X 1.5 " ON BEHALF OF ECOFASTEN SOLAR BY TUV RHEELAND REFERENCE FILE 0'-13" 2— / 3096 HAMILTON BLVD.BUILDINGS SEE DATASHEET� 16 SOUTH PLAINFIELD,NJ 07080 L2-ELS150128a (REV 1) 000 qui / MO(732)M 2-622 COM 3. ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511 AND IS THE CLIMATIC & GEOGRAPHIC DESIGN CRITERIA RESPONSIBILITY OF THE CONTRACTOR TO FILL ALL HOLES WATERTIGHT. a STRUCTURAL 4. "ROCK-IT" ATTACHMENTS ARE MANUFACTURED BY ECOFASTEN SOLAR, PHOENIX, / MINIMUMSSPACINGTOGUTTER ENGINEERING TABLE R301.2(1) ARIZONA. AND SHALL BE INSTALLED IN STRICT COMPLIANCE WITH / DANIEL W.DUNZIK RA LEED-AP ECOFASTEN SOLAR ROCK-IT 4.0 MOUNTING DETAIL LICENSE#039534 MANUFACTURERS PRINTED INSTRUCTIONS. / ECOFASTEN SOLAR ROCK-IT 4.0 RAIL-LESS MOUNTING (908)872 -366a GROUND SNOW LOAD(LBS/SF) 2S SYSTEM INTEGRATED WITH FLASHING,COUPLINGS 370 NI BROA BURNT HILL ROCK-IT TO RAFTER ATTACHMENT SPACING SCHEDULE _ AND ADJUSTABLE CLAMP ATTACHMENTS ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND SPEED (MPH) 140 AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& TOPOGRAPHIC EFFECTS B ULTIMATEROOF ZONE 1 ROOF ZONE 2&3 ATTACHMENTS WARNINGO MEET LOCALA AND STATE BUILDING OFTHE E COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR DESIGN ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A SPECIAL WIND REGION NO WIND MAX.SPAN/MAX. MAX.SPAN/MAX. LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. SPEED CANTILEVER CANTILEVER WIND BORNE DEBRIS ZONE 2 (MPH) (INCHES) (INCHES) SEISMIC DESIGN CATEGORY C 115 48"O.C./16"MAX. 32"O.C./12"MAX. .� 7/� 125 48"O.C./16"MAX. 32"O.C./12"MAX. FASTENER REQUIREMENTS: CLIMATE ZONE 5A " " 130 48"O.C./16 MAX. 32 O.C./12 MAX. TOTAL ARRAY AREA=479.41 SQ FT p •; —� ��� WIND EXPOSURE CATEGORY B 140 48"O.C./16"MAX. 24"O.C./10"MAX. WIND LOAD:ASCE 10(SEE CALCULATIONS,STRUCTURAL CERTIFICATION)50 PSF MAX TOTAL UPLIFT 50 PSF X 479.41=23970.56 LBS ( �p?I { °s �A 150 40"O.C./16"MAX. 16"O.C./8"MAX. I�- i-Q MAXIMUM SOLAR ARRAY ELEVATION:4.25" 160 32"O.C./12"MAX. 16"O.C./8"MAX. FASTENER: MAXIMUM CLAMP ATTACHMENT SPACING:48" —r TABLE REFLECTS ATTACHMENT SPACINGS THAT EXCEED MANUFACTURERS LAG SCREW SPEC 203.2,8/04:(FLAT WASHERS TO BE USED WITH LAG BOLTS) ,� *>;• SPECIFICATIONS FOR WIND LOADS AS PER ASCE 07-10. RISK CATEGORY II LAG BOLT WITHDRAWAL VALUE 5/16"DIA.,266 LB/IN X 2—INCH THREAD DEPTH: 532LB.CAP.EACH X39534 t� TOPOGRAPHIC EFFECTS B,C,&D AND ROOF WIND ZONES 1,2,&3. ROOF ZONES 2&3 "` _ �( MINIMUM NUMBER OF LAG BOLTS REQUIRED:23970.56 LBS/532 LBS/LAG BOLT=46 Q � COUPLING-" CLAMP-4ARE WITHIN 48"OF ANY OUTER EDGE,HIP, RIDGE,OR GUTTER LINE FOR STRUCTURES MAXIMUM SPAN BETWEEN MOUNTING FEET BOLTS"X"USE 48"MAX ALLOWED AS 30'-0" OR LESS MEAN ROOF HEIGHT. PER SCHEDULE SOLID BLOCKING GUTTER GUTTER STRUCTURAL STATEMENT: CUSTOMER BETWEEN JOISTS ® ® ® ® INFORMATION AS REQUIRED N THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE CATHERINE PLAIA-MS30379 ri W NEW LOADS IMPOSED BY THE PHOTOVOLTAIC MODULE 2155 GRAND AVENUE ® T © ® Lu SYSTEM INCLUDING UPLIFT&SHEAR.EXISTING RAFTER �Q ® MATTITUCK NY 11952 SIZES &DIMENSIONS CONFIRM TO IRC-2015 TABLE (516)380-1006 ® ® RIDGE RIDGE 'ECOFASTEN'ROCK-IT R802.5(1)-RAFTER SPANS. ATACHMENT SYSTEM ® ® Q ©® m ® MOUNTING BRACKETS AND HARDWARE MEET OR EXCEED IURISTICTION:SUFFOLK 'ECOFASTEN'EF-44R-SS-NDD UTILITY:PSEGLI ATTACHMENT AND BASHING W/ SOLAR MODULE Y NEYORK CRITERIA OFTTHE TOWN.ATE CODE REQUIREMENTS FOR THE DESIGN UTILITY ACCT#:9625516352 8 XHDF5 FASTENERS TO DECK EXISTING ROOF MEMBRANE, UTILITY METER#:46956054 'ECoFASTEN'SKIRT PLYWOOD DECK'AND PV SYSTEM RAFTER ® ® GUTTER ® GUTTER ol INFORMATION SYSTEM SIZE(DC):8.71 KW ROOF WIND ZONES AS PER IRC R301.2(7) 26 MODULES:LG LG 335N1C-A5 ROOF ZONES 2&3 ARE 48"FROM OUTTER ROOF EDGES, 26 INVERTERS: ENPHASE RIDGES, HIPS, RAKES,AND GUTTER EDGES FOR STRUCTURES IQ7PLUS-72-2-US BELOW 30'-0"MEAN ROOF HT. PROJECT INFORMATION ALL COMPONENTS SHALL BE AS MANUFACTURED BY'ECOFASTEN SOLAR'AND INITIAL DATE:7/10/2019 DESIGNER:TO INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURERS PRINTED SPECIRCATIONS. REV: DATE: DESIGNER: REV: DATE: DESIGNER: COVER PAGE PV- 1 ( 2)_ SCALE: 1/8" — 1'-O" ROOF MODULE COUNT TILT AZIMUTH SHADING O Disc CB R1 19 19° 249° 91% MSP R2 7 20" 69° 95% momentum FIRE SETBACK ELECTRICAL EQUIPMENT SOLAR (18" VENTILATION, 36" ROOF ACCESS) PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD.BUILDING B (lYP) SOUTH PLAINFIELD,NJ 07080 Q (732)902-6224 Q MOMENTUMSOLAR.COM STRUCTURAL ❑ ENGINEERING DANIEL W.DUNZIK RA LEED-AP LICENSE# 34 (908)872-3664 370 BURNT HILL ROAD Q K Q� SKILLMAN,NJ 08558 LU ❑ LLI ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE (D Q COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A ❑ LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. 0 O Q <1 Q Q GRED R1 A13 O �Cy �N�EL ./IN Q s DRIVEWAY D C 034�5 134 4� F `nI-��e c NEv R2 CUSTOMER 1 o INFORMATION ❑ CATHERINE PLAIA-MS30379 p 2155 GRAND AVENUE ❑ n MATTITUCK NY 11952 M (516)380-1006 U) SYMBOL LEGEND ❑® z JURISTICTION:SUFFOLK UTILITY:PSEGLI w m MSP MAIN SERVICE PANEL ® CHIMNEY UTILITY ACCT#:9625516352 Rl z ❑ UTILITY METER#:46956054 O SP SUB-PANEL z SKYLIGHT PV SYSTEM OM UTILITY METER ® VENT INFORMATION � ❑ AC SYSTEM SIZE(DC):8.71 KW W t o o DISC AC DISCONNECT O PIPE VENT 26 MODULES:LG LG 335N1C-A5 5 26 INVERTERS: ENPHASE IQ7PLUS-72-2-US ❑ UDC UTILITY DISCONNECT FAN ❑ GROUND ACCESS p p (TYP) LOAD CENTER SATELLITE DISH PRO]EGT INFORMATION ❑ LC N3R NEMA 3R BOX W/ENVOY-S ® FIRE SETBACKS INITIAL DATE:7/10/2019 DESIGNER:TO REV: DATE: DESIGNER: ❑ D O CB COMBINER BOX GROUND ACCESS REV: DATE: DESIGNER: SOLAR INSTALLER NOTES: PF PERFORMANCE METER PITCH DIRECTION PANEL LAYOUT NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED MODULE PV-2 R1 - ARRAY 1 LAYOUT DETAIL SCALE: 1/8" = 1'-0" TILT: 19° momentum -AZIMUTH: 249° SOLAR SHADING: 91% PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR oa-6ea 2 3096 HAMILTON BLVD.BUILDING B SOUTH PLAINFIELD,N]07080 27'_4" r 161-8ee , 111 (732)902-6224 1'-6" 4—9z 161-81' MOMENTUMSOLAR.COM 1'-6" STRUCTURAL d I DANIEL W.DUNZIK RA LEED—AP I •j LJ —— 'I� LICENSE#0395 34 08) . . , . 370 BURNT HILL ROAD 9 p �,�� ®_ ���� SKILLMAN,N7 08558 I Y I j( p +� I I f e I ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND I d ( �lI ! I AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& 1 ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE / 12'-5" 12e—Sea I COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR G •7 ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A / / •®• . P LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY / III1111 � 'I1� iII �I I �f fllfll�lI _ I l i f I_I W D� SOLAR INSTALLER NOTES: �y 03953A yO� NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED OF I�IrG R2 - ARRAY 2 LAYOUT DETAIL CUSTOMER SCALE: 3/16" = 1'-0" INFORMATION TILT: 20' CATHERINE PLAIA—M530379 AZIMUTH: 69° a lea lea 2155 GRAND AVENUE SHADING: 95% 81-8111 23 7 12 2-2 MATTITUCK NY 11952 (516)380-1006 1'-6, 11 / / +/ JURISTICTION:SUFFOLK UTILITY:PSEGLI 0 0 (] 0 UTILITYACCT#:9625516352 S'_2" UTILITY METER#:46956054 . . . . . . +. . . . . . . . . PV SYSTEM ��!! INFORMATION . SYSTEM SIZE(DC):8.71 KW 26 MODULES: LG LG 335NiC—A5 E 26 INVERTERS: NPHASE IQ7PLUS-72-2—US $'-S2_'" 111111111111111111111l1illlilii PR07ECT INFORMATION I_LLI I_! If I I I I I I I L INITIAL DATE:7/10/2019 DESIGNER:TO I REV: DATE: DESIGNER: REV: DATE: DESIGNER: LAYOUT DETAIL SOLAR INSTALLER NOTES: NO ADDITIONAL STRUCTURAL SUPPORT REQUIRED PV-3 26 LG LG 335N1C-A5335W MODULES PAIRED WITH momentum 26 ENPHASE IQ7PLUS-72-2-US MICRO-INVERTERS SOLAR BRANCH CIRCUIT A 13 MICRO-INVERTERS EXISTING SQUARE D 200A PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR 3096 HAMILTON BLVD.BUILDING B BRANCH CIRCUIT B MAIN SERVICE PANEL 240 V SOUTH PLAINFIELD,NJ 07080 13 MICRO-INVERTERS (732)902-6224 MAIN BREAKER:200A MOMENTUMSOLARRD COM INE SIDE STRUCTURAL -{- - -� - -{- - ENPHASE 80AAC HOT TAP ENGINEERING DANIEL W.DUNZIK RA LEED-AP COMBINER BOX 89L AC DISCONNECT LICENSE#039534 = W/ENVOY IQ 200A 3 08)872-366470 BURNT HILL ROAD f+ fv f SQUARE-D 60A FUSIBLE GRID SKILLMAN,NJ 08558 ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND �- AC DISCONNECT AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& 8 un ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A 40A LICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. ELECTRICIAN "ROOF0A BREAKER 60A FUSIBLE POWER UTILITY JEFFREY MARINELLpPRO CUSTOM SOLAR DBA MOMENTUM SOLAR (ENVOY) 3096 HAMILTON BLVD.BUAC -GROUND METERTERMINATION CAP BOX A BREAKER(A) souTN'�LAIN 4 LD,I�0708 1 -B 20A BREAKER(B)3 DISCONNEC 4 (732)902-6224 E D INSTALLED ON T C� L END OF CABLE � 03y53c} ELECTRICAL NOTES: 5.ALL CONDUCTORS ARE SIZED BASED ON NEC 2014 ARTICLE 310 10. SYSTEM COMPLIES WITH 690.12 RAPID SHUTDOWN AND ASSOCIATED 1.ALL CALCULATIONS FOR VOC,VMAX, IMP AND ISC HAVE BEEN 6.ALL EQUIPMENT INSTALLED IS RATED AT 75°C UNLESS NOTED LABELING AS PER 690.56(C).AC VOLTAGE AND SYSTEM OPERATING CUSTOMER CALCULATED USING THE MANUFACTURED STRING CALCULATOR BASED ON 7. INVERTER NOC(NOMINAL OPEN CURRENT)OBTAINED FROM CURRENT SHALL BE PROVIDED AS PER 690.52. INFORMATION ASHRAE 2%HIGH AND EXTREME MINIMUM TEMPERATURE COEFICIENTS. EQUIPMENT DATA SHEET 11. CONDUCTORS IN CONDUIT ARE AC CONDUCTORS-BRANCH 2. THE ENTIRE ARRAY IS BONDED ACCORDING TO (NEC 690.46 - 250.120 8. GROUNDING CONDUCTOR RUN WITH PHASE CONDUCTOR IN CIRCUITS AND NOT PV SOURCE CIRCUITS 690.6. CATHERINE PLAIA-MS30379 PARAGRAPH Q. THE SAME CONDUIT. 12.ALL GROUNDING SHALL COMPLY WITH 690.47(A)IN THAT THE AC 2155 GRAND AVENUE 3. THIS SYSTEM COMPLIES WITH NEC 2014 9.SYSTEM IS CONSIDERED AN AC MODULE SYSTEM.NO DC MODULES SHALL COMPLY WITH 250.64. MATTITUCK NY 11952 4. BRANCH CIRCUIT CALCULATION FOR WIRE TAG 1 DISPLAYS THE LARGEST CONDUCTORS ARE PRESENT IN CONDUIT, COMBINER,JUNCTION 13.NO TERMINALS WILL BE ENERGIZED IN THE OPEN POSITION IN THIS (516)380-1006 BRANCH CIRCUIT IN SYSTEM.OTHER BRANCH CIRCUITS WILL HAVE LOWER BOX, DISCONNECT.AND COMPILES WITH 690.6-NO DC. AC MODULE SYSTEM 690.6,690.17. DESIGN CURRENT THAN THE ONE SHOWN. DISCONNECT AND ASSOCIATED DC CABLING ARE REQUIRED. 14.WHERE APPLICABLE, INTERCONNECTION SHALL COMPLY WITH JURISTICTION:SUFFOLK 705.12(D)(3), 705.12(D)(2)(3)(B),705.12(A)AS PERMITTED BY 230.86(6) UTILITY: PSEGLI UTILITY ACCT#:9625516352 UTILITY METER#:46956054 PV SYSTEM INFORMATION SYSTEM SIZE(DC):8.71 KW 26 MODULES: LG LG 335N1C-A5 26 INVERTERS: ENPHASE IQ7PLUS-72-2-US Wire Tag Conduit Wire Qty Wire Wire Type Temp. Wire Temp. Conduit Derated Inverter NOC(A) NEC Design Ground Ground Wire Gauge Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty Correction Current(A) Size Type PR03ECr INFORMATION 1 OPEN AIR 2 12 AWG Trunk Cable 90°C 30 0.96 1 28.80 13 1.21 1.25 19.66 12 AWG Trunk Cable INITIAL DATE:7/10/2019 DESIGNER:TO REV: DATE: DESIGNER: 2A 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 13 1.21 1.25 19.66 08 AWG THWN-2 REV, DATE: DESIGNER: 26 1" PVC 2 10 AWG THWN-2 90°C 40 0.96 0.8 30.72 13 1.21 1.25 19.66 08 AWG THWN-2 ELECTRICAL 3 1" PVC 3 08 AWG THWN-2 75°C 50 0.96 1 48.00 26 1.21 1.25 39.33 08 AWG THWN-2 4 V PVC 3 06 AWG THWN-2 75-C 1 65 0.96 1 1 62.40 1 26 1.21 1.25 39.33 08 AWG THWN-2 PV-41 TAG LABEL QUANTITY LOCATION NOTE EXAMPLES O AWARNING1 AT EVERY SEPARATION BY 12 DC CONDUITS ENCLOSURES/WALLS/ ( momentum PARTITIONS/CEILINGS/FLOORS PHOTOVOLTAIC POWER SOURCEOR NO MORE THAN 10' SOLAR PRO CUSTOM SOLAR LLC D.B.A.MOMENTUM SOLAR A . �� • © 3096 HAMILTON BLVD.BUILDING B � NINGPHOTOVOLTAIC SOUTH PLAINFIELD,NJ 07080 EQUIPPED 1 AT ANY JUNCTION BOX OR DC (732)902-6224 RAPID SHUTDOWN 1 COMBINER BOX MOMENTUMSOLAR.COM PHOTOVOLTAIC • -• - SOURCE COMBINER IF USED STRUCTURAL ENGINEERING O DANIEL W.DUNZIK RA LEED-AP LICENSE#039534 (908)872-3664 370 BURNT HILL ROAD SKILLMAN,N7 08558 A . RNING ENGINEERING LETTER ATTACHED HAS SPECIFICATIONS FOR WIND AND LOAD CALCULATIONS FOR SOLAR INSTALLATION SPANS& ATTACHMENTS TO MEET LOCAL AND STATE BUILDING CODE COMPLIANCE.WARNING THAT IT IS A VIOLATION OF THE LAW FOR ANY PERSON,UNLESS ACTING UNDER THE DIRECTION OF A © - •• 1 JUNCTION BOX 1 AT ANY JUNCTION BOX OR DC , •NNLICENSED ARCHITECT,TO ALTER AN ITEM IN ANY WAY. ELECT• NOT TOUCHCOMBINER IF USEDJI TERMINALS • BO . -- -- •A. . ENERGIZED -- tiRED HRC IN I HL OPEN POSITION INARNING NP���W DUN�y�I(� PHOTOVOLTAIC AC DISCONNECT lj�WARNING Y OPERATING CURRENT 1 OF EACH AT FUSED AC SHOCK HAZARD DISCONNECT 0DO NOT TOUCH 395;jG OPERATION - - I , Q ODBOTH •TERMINALS' , CURRENT 1 AC DISCONNECT OOMPLEON V TERMINALS ON VOLTA AND © ��• LOAD BEENERGIZED DISCONNECT LABEL IN THE OPEN POSITIONi • CUSTOMER INFORMATION BREAKER A L' CATHERINE PLAIA- MS30379 BACKFEEDWARNING 2155 GRAND AVENUE 0 DUAL POWER • - • - 1 MAIN DISCONNECT 1 OF EACH AT BUILDING MAIN � �- MATTITUCK NY 11952 SECi O (516) 380-1006 PANEL DISCONNECT PANEL --- • . • PHOTOVOLTAICiao.u�esa SYSTEM ` JURISTICTION:SUFFOLK UTILITY: PSEGLI UTILITY ACCT#:9625516352 AWARNING ' UTILITY METER#:46956054 PV SYSTEM 0 DUAL POWER SOURCE 1 UTILITY METER 1 AT UTILITY METER OO INFORMATION 'SECOND SOURCE PHOTOVOLTAIC SYSTEM SIZE (DC):8.71 KW 26 MODULES: LG LG 335N1C-A5 y : ` 26 INVERTERS: ENPHASE MEANS OF INTERCONNECTION LOCATION NOTE IQ7PLUS-72-2-US MAIN SERVICEPROTECT INFORMATION © BACKFEED BREAKER 1 PANEL OR PER 705.12(D)(2)(3)(c) DISCONNECT INITIAL DATE:7/10/2019 DESIGNER:TO REV: DATE: DESIGNER: MAIN SERVICE J REV: DATE: DESIGNER: O LINE SIDE TAP 1 PANEL OR PER 705.12(D)(2)(3)(c) © ` ' EQUIPMENT LABELS DISCONNECT PV-5 The new EcoX is an innovative, rail-less racking system,proven AMU- to organize the installation process. The flexible design offers a clean aesthetic, simplified logistics,and delivers a higher quality installation at a lower cost per watt. Aesthetic Design Cable Management A wide range or adjustment makes it easy to install a Whether installing with Microinverters,Power straight,level system. Components are designed to Optimizers,or String Inverters,EcoX provides wire y blend into the array,and the aesthetic skirt creates management provisions to both prep the modules,and N° a Rnished look Alternatively,a skirt Free option is to route homerun or trunk cables throughout the array available to provide a more traditional look. Flexible System Design Single Point Grounding ' The EcoX Estimator is a powerful racking system EcoX and approved modules create a continuously design tool.The user inputs all site conditions and bonded system.The installer can connect a finished can layout multiple rooFsurfaces The EcoX Estimator array to ground with a single bonding lug outputs a site speaFc design package with engineering specs and bill oFinaterials �w ' Technical Specifications - j Racking components.Aluminum,stainless hardware,dark Fast. Simple. Supported. Materials bronze anodized upper surface,mill tlower surfaces Flashings.Aluminum,black powder coated finish Modules drop In From above Universal components mount to The Ecolibrium field support team Grounding/BcndingValidation UL2703-see installation manual For specific module approvals and there is never a need to standard Framed modules With oFFers on-site installation training - - - — reach over or walk on modules. a single socket size and a wide and ongoing technical support. fire Resistance Validation UL2703-Class A,Type 1 and Type 2 modules Pre-assembled components range o adjustment,It is quick And From project planning to Mechanical Load Validation UL2703-see installation manual Forspecr6cmodule approvals and quick connections make and easy to Install any array logistics to Installation,we are _ —_ EcoX easy to install with a clean,finished look dedicated to customer service. Flashing Validation ICC-ES AC286/UL441 Rain Test For Roof Flashing F ustabiht y 1"vertical range,3 5"North/South range, Ad — connect anywhere in East/West direction w. Warranty 15 years salesteecolibriumsdarcom US 740-249-1877 wunvecolibriumsolarcom EcoliblriumSolar sales(Aecolibnumsolarcom US 740-249-1877 wwwecohbnumsolarcom I Ecdibdumsolar LG NeON 2 ® LG Life's(food Mechanical Properties Electrical Properties(STC*) e e Cells 6.10 _ Module__ LG335N1C•A5 LG330N1C-A5 L6325NiC-A5 Cell Vendor LG Maximum Power(Pont) 335 330 325 Cell Type More'uYst-d-fN type MPP Vohnge(Vmpp) 31.1 33.7 333 Cell Dimensions 1617x 1617 num/6 inches MPP Cumm(Impp) 9.83 99 977 e of 8usbar 12(Muhl VWRet6bar) Open Circuit Voltage(Yoe) 410 40.9 40.8 rMMMU Dimensions(LxWxN) 1686 1016 40 mm M erteey (Ne) 19.6 19.3 10A16638 40x 1571mh Mad I Efficxwrry 19.6 19.3 190 Front Load 6000Pa Ope tog Tempimmuro -40-+90 - Rei Load 5400Pa MaximumSystemoee 1.000 Weight 18kg M Se Free artti9 20 -- Jorioriype MC4P Tek (ft) 0-e3 lunRfon Bm P68 wkh 3 Bypaz Diodes 1 maze 1000 Wmr'Mwrre Iwlpreave2a,n Cables 1000 mx2ea car tsv.am zmwmpawlatmronWMYANx)oft Glass High Tnrnmlaron Tempered Glass Frame Arid ind Aluminium (MOM)Electrical Properties(NO ) Certifications and Warranty Module L613SrI1C,115 LG370M1C-A5 L632511111C-AS Certifications EC 61215,EC 61731)1lt2 _ Maximum P_'(P—) 247 243 240 (A 1703 MPP Vohage(vmpp) 315 312 309 EC 61701(Sah mist com—test) U"Cumern(Impp) 7.83 791 7.78 EL 62716(Ammonia o—eon tat) c rc-Va LG NeON"2 _ �eet(b SA4 391_ -__38.0 1509001_ Slrort C4cult cumart(W BA4 SAI 8.38 Module Fire Pert-(USA) Type 'Wx'1(rbrarar;vemstw r�praua)+namwaOOWb',emleets�psmia A'C wMspse tmh Fire Retmg(CANADA) claszC(L)IC/ORDC1703) P-&-werreoey -_ _ 12 years --- LG's new module,LG NeONTM 2,adopts Cello techrldogy outpue w.maiey of Peeve Lnmr warnmy Dimensions(mm/in) Cello technology replaces 3 busbars with 12 thin wires ID - 60 ee U to enhance power output and reliability NeOMw Z /\/����J�� C r♦ \M�J`� ) demonstrates LG's efforts to increase customer's omer's values f�E a�•-� `\ � Teoyferatlue Characteristics beyond efficiency.It fe tyres enhanced wananty,durability, Ireerlek performance under real environment,and aesthetic Nut? 45 t 3 deslgn suitable for roofs. PmnP _ 037%rc Ver -027%FC isc 0.03%rC � x Characteristic Curves .n. .. Enhanced Performance Warranty High Power Output „m — LG NeON"'2 has an enhanced performance warranty Compared with previous models, he I WGN'"2 �r The annual degradation has fallen from 0.6%/yr to has been designed to significantly enhance its output -0 55%/yr Even after 25 years,the cell guarantees 1.2%1, efficiency,thereby making it efficient even in limited space, more output than the prevlous LG Ne0NTM 2 modules axM� Aesthetic Roof ® Outstanding Durability a waw m i LG NeONn"2 has been designed with aesthetics in mind-. With its newly reinforced frame design,LG has extended N 1 thinner wires that appear all black at a distance. the warranty of the LG NeONte 2 for an additional The Product may help increase the value of 2 years.Additionally,LG NeON"'2 can endure a front K K a property with its modem design bad up to 6000 Pa,and a rear bad up to 5400 Pa. 9 r« Lill, Better Performance on a Sumy Day Double-Sided Cell Structure LG NeOM"2 now performs better on sTy days thanks The rear of the cell used in LG NeOM"2 will umoribute toto its improved temperature ocef6Cienty. g4Bir of t e module Es reabsorbed dE led t bean ratIea gr at t t the rear of the nodule n reabsorbed m generate a groat amountofaddidmalps-er ®LG LNG nDler`t au=w,le« Ukt Geed 1000sywnAaEnglwodCMam N107632 i PCmogArx�yttap0ad20o1f7 wLGa Evlreeuwrobni xascroAg hrig�lxqse rewxwrwveudcmka Yxwtbn laraeeanerlrN t0 About W Electronics Cmr,x.t 01/01/2017 wwwlgsoLuusa.rnnl �i LG Ek�lrurras n a 0h�ha:player who has deco wrnn.ned lu expardrrrg its.apazity,heed un molar energy bra ns fun re growth enyrx:.We embwked on a suer erergy sou rerewch program ' 1 gas,wPP_ab im r�s ml,erperknx h ae�.mrbr.tac LCD,dwn4stri mod metadJsWoe"..Ura rmeriay releii the 6ret Mom%earls m the mei in 2014 arhth aireupwud.32 c ontnes m 1 g years,thereafter In 2013.LG NeON-(mevously ko—a Moa X'NOON)won 1--61 Aware,,whxh proud LG a the leader or rnmwarun m the iiMo,ii, Data Sheet Enphase Microinverters Enphase IQ 6 and IQ 6+Microinverters INPUT DATA(DC) IQ6-60-2-US AND I06-60-5-US 106PLUS-72-2-US AND 106PLUS-72-6-US Commonly used module pairings' 195W-330w+ 235W-40_0W- Module 35W-400W+Module compatibility 60 cell PV modules only 60 cell and 72 cell Pv modules The high-powered smart grid-ready Maximum input DC voltage 48 V 62 V Peak power tracking voltage 27 V 37 V 27 45 VEn Enphase Enphase IQ 6 Micro"and Enphase IQ 6+Micro" Operating range 16 V-48 V 16 V-62 V Q6 a n d I Q 6+ dramatically simplify the installation process while Mm!Max start voltage 22 V,48 V 22 V/62 V achieving the highest efficiency for module-level Max DC short circuit current(module Isc) ISA 15A Microinverters p0 DC pont ackfege ss under single II II power electronics. DC port backfeed under single fault O A O A Part of the Enphase IQ System,the IQ 6 and IQ PV array configuration 1 x 1 ungrounded array;No additional DC side protection required, AC side protection requires max 20A per branch cimuil 6+Micro integrate seamlessly with the Enphase OUTPUT DATA(AC) IQ6.60-2-US AND 106-60-5-US 106PLUS-72-2-US AND IQ6PLUS-72-5-US IQ Envoy'",Enphase Q Aggregator'",Enphase IQ Peak output power -- -z40 VA —-- -- 290 VA -- Battery",and the Enphase Enlighten'monitoring Maximum continuous output power 230 VA 280 VA Nominal voltage/range' 240 V/211 264 V 208 V(10)/183229 V 240 V/211.264 V 208 V(10)/183 229 V and analysis software. Nominal output current 0.96 A 1.11 A 1.17A 1 35 A The IQ 6 and IQ 6+Micro extend the reliability Nominal frequency 60 Hz 60 Hz Extended frequency range 47 68 Hz 47 68 Hz standards set forth by previous generations and Power factor at rated power 10 1 0 undergo over a million hours of power-on testing Maximum units per 20 A branch circuit 16(240 VAC) 13(240 VAC) Enabling Enphase to provide an industry-leading 14(single-phase 208 VAC) 11(single-phase 208 VAC) warranty of up to 25 years Overvohage class AC port III III AC port backfeed under single fault 0 A 0 A Power factor(adjustable) 0 7 leading 0 7lagging 0.7 leading. 0.7 lagging EFFICIENCY @240 V @208 V(10) @240 V @208 V(10) Easy to Install CLC weighted efficiency 910% 965% 970% 96.5% • MECHANICAL DATA Lightweight and simple Ambient temperature range -40°C to+65°C • Faster installation with improved two-wire Relative humid dy range 4%to 100%(condensing) cabling Connector type MC4 or Amphenol H4 UTX Built-in rapid shuldown compliant(NEC 2014) Dimensions(WxHxD) 219 mm x 191 mm x 379 mm(without bracket) Weight 1.5 kg(3 3 lbs) Productive and Reliable Cooling Natural convection No fans Approved for wet locations Yes •Optimized for high powered 60celland 72- Pollution degree PD3 cell*modules Environmental category/UV exposure rating Outdoor-NEMA 250,type 6(IPI More than a million hours of testing FEATURES • Class 11 doubleinsulatedenclosure Communication Power line Monitoring Enlighten Manager and Mytnlighten monitoring options Compatible with Enphase IO Envoy Smart Grid Ready Compliance UL 621091,UL1 741/IEEE1 547,FCC Part 15 Class B,ICES 0003 Class B. CAN/CSAC22 2 NO 1071-01 • Complies with fixed power factor,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014 and frequency ride-through requirements NEC 2017 section 69012 and C22.1 2015 Rule 64.218 Rapid Shutdown of PV Systems,for AC • Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions. grid requirements 1 No enforced DC/AC ratio Seethe compatibility calculator at ennhase com/an us/support'module comnat bility. •Configurable for varying grid profiles 2.Nominal voltage range can be extended beyond nominal if required by the utility. UThe 10 6,1 Micro is required to support 72cellmodules To learn more about Enphase offerings,visit enphase.eom E N P H AS E. .2017 Ensrner pha m - gy All nghi s re.erw,d Nmm I W;deks or brands used are the property of Frghase'rorgy Inc To learn more about Enphase offerings,visit enphase.co %./ zol7asol n E N P H AS E.