Loading...
HomeMy WebLinkAbout44086-Z r Town of Southold 9/20/2019 o - P.O.Box 1179 o • 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 40707 Date: 9/19/2019 THIS CERTIFIES that the building OTHER Location of Property: 2600 S Harbor Rd, Southold SCTM#: 473889 Sec/Block/Lot: 75.-7-7.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 8/12/2019 pursuant to which Building Permit No. 44086 dated 8/22/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: wood stove in existing one family dwelling as applied for. The certificate is issued to Bokros,Aaron&Delaney,Alison of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED I V Au o ' ed i ature #OC4401,� TOWN OF SOUTHOLD � BUILDING DEPARTMENT y TOWN CLERK'S OFFICE '� • SOUTHOLD, NY - BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 44086 Date: 8/22/2019 Permission is hereby granted to: Bokros, Aaron 2600 S Harbor Rd Southold, NY 11971 To: install wood stove in existing single-family dwelling as applied for. At premises located at: 2600 S Harbor Rd, Southold SCTM # 473889 Sec/Block/Lot# 75.-7-7.1 Pursuant to application dated 8/12/2019 and approved by the Building Inspector. To expire on 2/20/2021. Fees: SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $200.00 CO -ALTERATION TO DWELLING $50.00 Total: $250.00 Bui g Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: APoo 5-R(}1/ow 9-co-A 01\o- +.o\A House No. Street Hamlet Owner or Owners of Property: Wtakrrm -v- 6 &pin S Suffolk County Tax Map No 1000, Section Block Lot `7 Subdivision Filed Map. Lot: Permit No. 4�O Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporary Certificate Final Certificate: (/ (check one) Fee Submitted: $ V� Applicant Sign ur 50Ulyo * # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION , [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATIN r /`� [ ] FRAMING /STRAPPING [ FINAL cab F� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE INSPECTOR FIELD INSPECTION REPORT7 DATE COMMENTS X-; FOUNDATION(1ST) ------------------------------------ FOUNDATION(2ND) SLJ o y ROUGH FRAMING& PLUMBING r INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS z X b � z � x d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval FAX:(631)765-9502 Survey 44dZ-Southoldtownny.gov PERMIT NO. Check Septic Form NYSDEC Trustees C O Application Flood Permit Examined 20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved ,20JJ Mail to Disapproved a/c Phone Q�� xp�ratton•- , a-m0 tz Builg s ctor AUG 1 2 2019 APPLICATION FOR BUILDING PERMIT Date 8 August ,2019 rJarIDI�GDTFP , INSTRUCTIONS 1hir; pp i of Y' IJe completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale Fee according to schedule b Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways c The work covered by this application may not be commenced before issuance of Building Permit d Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant Such a permit shall be kept on the premises available for inspection throughout the work e No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy f Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months Thereafter,a new permit shall be required APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections (Signature of applicant or name,if a corporation) 2600 S Harbor Rd,Southold,NY 11971 (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder Owner Name of owner of premises Alison Delaney and Aaron Bokros (As on the tax roll or latest deed) If applicant is a corporation,signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 2600 S.Harbor Rd Southold House Number Street Hamlet County Tax Map No. 1000 Section- -7 -5 Block �7 Lot I Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single Family Dwelling b. Intended use and occupancy Singel Family Dwelling 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work Installation of wood burning stove (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions. Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law,ordinance or regulation?YES_NO 13. Will lot be re-graded?YES_NO Will excess fill be removed from premises?YES_NO 14.Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES NO * IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS COUNTY OF ) ft, 0O%Ll- J�t being duly swom,deposes and says that(s)he is the applicant (Name of individual signo contract)above named, (S)He is the - (Contractor,Agent,Corporate Officer,etc) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application, that all statements contained in this application are true to the best of his knowledge and belief,and that the work� lE BUNCH performed in the manner set forth in the application filed therewith UV PUb6C,State of New Sworn to before me this No.016U6185050 � day of 20 lel Qualified in Suffolk Co' . Commission Expires Ann! I4• �-(AC) Notary Public Signator licant rlu 0lwuvav YlYibdmmCu-I ' rl Nowirso APPRO7 . ED AS NOTED DATE: B.P.# FEE: gy. I stallatim and Operating Instructions , NOTIFY BUDDING DEPWMENT AT Morso , 7110 ` 765.1802 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED ,For use in North America FOR POURED CONCRETE 2. ROUGH >FRAMING & PLUMBING 3. INSULATION` 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL,CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN COD s AS REQUIRED AND CONDITIONS D TOWN ZBA Ik1Q10 TOWN PLANNI BO SOI DOD n IOWN TRI ISTEES OCCUPANCY OR MORSO JERNSTOBERI A/S.DK-79oo NYKOBING MORS E-Mail:stoves@morsoe.com`Website:www.morsoe.com USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY Congratulations on the purchase of your new Morso stove! Morso, which is the largest supplier for the Dan- ish market, has manufactured stoves of the highest quality sincei853.By following the instructions over- leaf,we are sure that you will enjoy the use and the benefits of your stove for many years to come. Contents A.10, 'Installation of your Morso stovePage no. Checking loose-'partsYin the-stove; -1.2 The chimney/flue system `5 i.3 -Flue connection 6 . 1.4 Connection to the existing chimney 6 ; i:5 Positioning the stove' ;.8., 1.6 - Mbbile,h6me installation 9 ' - 2.0 ; Operation 2.i Before you start firing ; 1i zz L'ighting&loading intervals ,12,' 3.0 Maintenance 16 3,i Exterior maintenance 3.2 'Internal maintenance-' i6 3.3 Cleaning the stove&the flue i8 - 3.4 Leaving the stove for extended,periods _ ig- 3'.5 Parts diagram 26 - .3.6 'Parts list '21 Read this entire manual before you install and use your new room heater.If this room heater is not properly installed,a house fire may result.To reduce the risk of fire,follow the installation instructions.Failure to follow instructions may result in property dam- age,bodily injury,or even death. Contact local building officials about restrictions and installation inspectionrequirements in your area. Save these instructions 2 r- �� c�:=lnstaM Installation of woodburning stoves must be safe and legal. If your Morso stove is not installed correctly,it may cause a house fire.To reduce the risk of fire,the installation instructions must be followed carefully.Contact the local building officials about restrictions and installation inspection in your area. Before you start installing your stove,make sure that. - The stove and chimney connection are placed far enough from combustible materials to meet all clearance requirements. - The floor protection must be adequate and must be made correctly according to the re- quirements. All neccessary approvals are needed from the local building officials. The data plate,which is located on the back of the stove,provides information regarding safety testing information,name of certified testing laboratory,and installation requirements. Installation requirements vary in different districts,and the local building officials have the final authorization to approve your installation. You should discuss the installation with them before beginning Please ask your dealer for further information. Do not connect to any air distribution duct or system. Important:If the installation instructions are not followed carefully,it may cause dan- gerous situations like chimney-and house fires.Follow the instructions carefully and do not deviate from them as it may cause injuries to people or property. 1.1 Checking loose parts in the stove After unpacking,check that the firebricks are firmly in position and have not shifted in transit Check also that the air control works freely. See separate Assembly Instructions for Legs,Fitting for handle,and Baffles Before starting the initial fire,place the two cast iron battles above the three stainless pipes that supplies the secondary air The baffles are enclosed in the stove on delivery.Afterwards,place the carbowool blanket carefully above the two cast iron baffles. Make sure that the upper heating shield,the cast iron baffles,and the carbowool blanket are placed correctly before the fire is started. Standard Accessories A Morso glove and ceramic flue connection gasket are standard accessories that usually can be found in the ashpan or firebox area 4 1.2 The chimney/flue system Note that the flue system must be independently secured and must not rely on the stove for support The stove must not be connected to a chimney flue serving any other appliance. (Several flues may run up a single chimney stack;use one flueway per appliance). Use a residential type masonry or listed type HT factory-built chimney. High Temperature(H.T.)Chimney Standard UL-103-1985(21oo°F.)or a code-approved masonry chimney with flue liner for the USA, and High Temperature(650°C)Standard ULC S-629 for Canada. The internal dimensions of the chimney connector and chimney must not be less than 6 inches diameter(or equivalent cross section),and should not be significantly larger than this Too large a section will tend to allow the flue gases to cool excessively,causing sluggishness or unpredict- ability in the stove's performance. We recommend the length of the chimney system should be at least 16 feet(not required) above the stove in normal domestic situations, measured from the flue collar to the top of the chimney Local conditions like for example-roof constructions,large trees nearby and high altitude, may influence the chimney draft and height.Therefore,contact the local professional chim- ney sweep or your Morso dealer. Typical factory-built or masonry chimney installations Ganney, ;I --��nnneno, - � Clay We or outerun r� Celmg supported Wdl seppoded ^ §tnsonry Clianney 5 1.3 Flue Connection The stove is supplied from the factory with a flue collar fitted to the top plate and a round blanking plate blocking off the rear flue exit(behind the rear shield plate). Use a 24 MSG black or blue chimney connector or listed double wall chimney connector Re- fer to local codes and the chimney manufacturer's instructions for precautions required for passing a chimney through a combustible wall or ceiling Remember to secure the chimney connector with a minimum of three screws to the product and to each adjoining section The collar can be fitted to the rear outlet.Simply knock out the round panel on the rear heat shield plate to reveal the cast iron plate Untwist the blanking plate and the flue collar and swap their positions Re-secure by pushing down and tighten the enclosed screws Position the stove and connect to the flue system Wear gloves and protective eyewear when drilling,cutting or joining sections of chim- ney connector. 1.4 Connection to the existing chimney A chimney connector is the double-wall or single-wall pipe that connects the stove to the chim- ney The chimney itself is the masonry or prefabricated structure that encloses the flue.Chim- ney connectors are used only to connect the stove to the chimney Double-wall connectors must be tested and listed for use with solid-fuel burning applianc- es.Single-wall connectors should be made of 24 gauge or heavier gauge steel Do not use galvanized connector;it cannot withstand the high-temperatures that smoke and exhaust gases can reach, and may release toxic fumes under high heat.The connector must be 6 inches(150mm)in diameter If possible,do not pass the chimney connector through a combustible wall or ceiling. If passage through a combustible wall is unavoidable,refer to the sections on Wall Pass- Throughs.Do not pass the connector through an attic,a closet or similar concealed space when installing the chimney connectors. It is important to keep the flue gases moving smoothly in the right direction. Do not vent into a large void at this location,rather form one continuous section all the way up.Use mild bends(e.g.450 vs.go°)rather than sharp angles where a change of direction is required All parts of the venting must be accessible for cleaning purposes In horizontal runs of chimney,maintain a distance of 18 inches from the ceiling.Keep it as short and direct as possible,with no more than two go degree turns.Slope horizontal runs of connector upward 1/4 inch per foot(20 mm per metre)going from the stove toward the chimney.The recommended maximum length of a horizontal run is 3 feet(1 metre),and the total length should be no longer than 8 feet (2.5 metres). Information on assembling and installing connectors is provided by the manufacturer's in- structions exactly as you assemble the connector and attach it to the stove and chimney. Be sure the installed stove and chimney connector are correct distances from near by combustible materials.See the clearance paragraph page 8. Where passage through a wall or partition of combustible construction is desired,the in- stallation shall conform to CAN/CSA-B365 6 Chimney Connector Systems and Clearances from Combustible Walls for Residential Heating Appliances Minimum Uemnay clearance to brick and combustibles 2 in.is mm) Mrmmum eleerara:e in(305 of brickk A Minimum 3.5-in thick brick masonry all framed of into combustible wall with a minimum of 12-in brick separation from clay liner to combustibles. c Chimney The fireclay liner shall run from outer surface of connector brick wall to,but not beyond,die Inner surface I.Lnimum �-� Fife clay of chimney flue Inver and shall be fin»ly 12 in(305 mm) Masonry cmmney hoof to combustibles constructed to cemented in place. , NEPA 211 M.mmum ch,mnay clearance from masonry to sheet steel supports and combustibles 2,n,(SI mm) M.mmum clearance 9 m.(229 mm) Facto built NonsolUDlo cNmne length rohaclory cna,noy 13 Solid-insulated,fisted factory-built chimney rwmem connaclor length of the same inside diameter as the CtumnLh Rush wthluu9de chimney connector and having 1-in or more of flue use chimney of insulation with a minimum 9-in airspace Mrs pans to Air space ° eaarh conr»ctor between the outer wall of the chimney length 9 In(229 mm)mm E 2 \ socureiy �— and combustibles. sofid•m..ulaled, listed faelory built Masonry cmmney chimney length constructed to NFPA211 Sheet stool supports Minimum chimney clearance to sheet steal supports and combustibles 2 I(51 mm) C Sheet steel chimney connector,minimum 24 1 gauge in thickness,with a ventilated thimble, HIM PEI Two ah channels minimum 24 gauge in thickness,having two each 1 In(25.4 rvn) J I-in air channels,separated from combustibles Chimney by a minimum of 6-in.of glass fiber insulation. connector Opening shall be covered,and thimble supported with a sheet steel support,minimum 24 gauge in l Minimum 6lm thickness. r(152 mm)glass Two rmtilaW.it 11 fber his ation channels each t) 1 In.(25 4 mm) construction of Masonry chumnoy shoot'Iee1 .heel.teal constructed to supports NFPA 211 D Solid insulated,listed factory-built chimney Minimum c hmney clearance length with an inside diameter 2-m.larger than to sheet steel supports and combustibles Mmimum etearanco the chimney connector and having I-in.or more s apeot str'seel 2 in(51 1M1) I 21n.(51 mm) of insulation,serving as a pass-through for a single II} 1 In(254.mm) wall sheet steel chimney connector ofmlmmum airspace to Chimney chimney knglh 24 gauge thickness,with a minimum 2-in air space section between the outer wall of chimney section and Chmne combustibles. Minimum length of chimney section connector shall be 12-in chimney section spaced 1-in away Ch,mney from connector using sheet steel support plates connector fur pace Chimney lengN on both ends of chimney section. Opening sliall be s 2 in(51 mm) covered,and chimney section supported on both htasonrychimney Sheetsteel constructed supports sides with sheet steel supports securely fastened to to NFPA 211 Kull surfaces of minimum 24 gauge thickness. Fasteners used to secure chimney section shall not penetrate chimney flue liner. 7 1.5 Positioning the stove Distance to walls and lintel When the stove Is positioned near combustible materials,observe all current local and na- tional building regulations with regards to clearances.Whatever regulations apply to your area,do not In any case Install the stove within 8 Inches of combustible materials around the sides or 16 Inches above the top of the stove (fireplace Installations require greater clear- ances above the stove-see below In the clearance chart) These distances may need to be Increased If the materials are sensitive to heat.Note also that wall paper and other decora- tive materials may become detached with the effects of heat and care should be taken to ensure that they do not fall towards the stove in such an event When the stove is positioned near non-combustible materials,a gap of 4 inches or more Is recommended for cleaning purposes and to ensure that heat circulates around the stove and out Into the room If using rear exit,the floor protection must extend beneath the chimney connector and 2-In beyond each side. CLEARANCE REQUIREMENTS STANDARD RESIDENTIAL INSTALLATION SINGLEWALL&DOUBLEWALL CONNECTOR USA CANADA A Sidewall to unit 16" 18"-457 mm B Backwall to unit 65" 95"-241 mm C Cornerwall to unit 8 5" 8 5"-216 mm D Sidewall to connector 23" 25'-635 mm E Backwall to connector 10" 13"-330 mm F Cornerwall to connector 175' 175'-445 mm G Unit to ceiling 565 56 5"-1435 mm H Floor to ceiling 84" 84"-2134 mm MINIMUM CLEARANCES TO COMBUSTIBLES: DEGAGEMENTS MINIMAUX AUX MATERIAUX COMBUSTIBLES: BACKWALL/ ADJACENT WALL! MURARRIERE MURADJACENT �a cv WI7 E F ' >n vm QW STOVE y c POELE $ m F �r- y� CLEARANCE REQUIREMENTS ALCOVE INSTALLATION WITH DOUBLE WALL CONNECTOR A Sidewall to unit 19"(483 mm) B Backwall to unit 9 5"(241 mm) C Cornerwall to unit N/A D Sidewall to connector 26"(66o mm) E, Backwall to connector 14"(356 mm) F Cornerwall to connector N/A G Unit to ceding 205"(521 mm) H. Floor to ceiling 48"(1219 mm) 8 NONtOMOUSTIBLE FLOOR PROTECTOR ALCOVE INSTALLATION 0"MIN. l BACKWALL �—+ O MIN. STOYi MIN. a D E B G H � 16tel N A STOVE o 0 °' STOVE FLOOR PROTECTOR MUST BE NON-COMBUSTIBLE MATERIAL,IT MUST EKTEND BENEATH HEATER,AND 'Maximum alcove depth must be no more than 32"(813mm) TO THE FRONTISN)MEAR AS INDICATED. Distance to furniture The recommended minimum distance from stove to furniture is 30 Inches Note that some furniture is more easily affected by heat and may need to be moved to a greater distance. This is your responsibility. In addition other combustible materials,away from the stove.In general,a distance of 30 inches must be maintained between the stove and moveable combustible item such as dry- ing clothes,newspapers,firewood etc. 1.6 Mobile Home Installation The Morsra 7110 can be installed in a mobile home if equipped with an outside combustion air kit,a terminal cap with a spark arrestor,and if It meets the following Installation require- ments: - The stove must be secured to the mobile home structure by bolting through the hearth pad and into flooring. - The stove must be Installed with a listed Type HT chimney connector,HT Chimney,and terminal cap with spark arrestor.Never use a single wall connector(stovepipe)in a mo- bile home Installation. - Floor protection requirements in section 15 must be followed precisely. - In Canada,this appliance must be connected to a 6"(152 mm)factory-built chimney conform- ing to CAN/ULC-629M,STANDARD FOR FACTORY BUILT CHIMNEYS.Floor protection as referenced in section 1.5 must be followed,as well as'use of Canadian Floor Protector - Follow the chimney and chimney connector manufacturer's instructions when Installing the flue system for use In a mobile home. - Outside air kit should be Installed according to installation guide in the kit. - Intake air piping can be installed through the floor into a vented crawl space or through the wall of the residence to obtain outside air. - Install in accordance with 24 CFR,Part 3280(HUD). - NOTE Top sections of chimney must be removable to allow maximum clearance of 13.5' from ground level for transportation purposes 9 WARNING: NEVER DRAW COMBUSTION AIR FROM A WALL,FLOOR OR CEILING CAVITY OR FROM ANY ENCLOSED SPACE SUCH AS AN ATTIC OR GARAGE. DO NOT INSTALL IN A SLEEPING ROOM. CAUTION: THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR,WALL,AND CEILING/ROOF MUST BE MAINTAINED(I.E.,DO NOT CUT THROUGH FLOOR JOIST,WALL STUD,CEILING TRUSS,ETC.) DO NOT USE A GRATE TO ELEVATE FIRE-BUILD FIRE DIRECTLY ON HEARTH. ___PARE ETINCELLES EMBASE TEMP@TE -CHEMINtE REPERTORI@E SOLIN TOIT/SUPPORT CONDUIT CHEMINEE RitPERTORIE PROTECTION KIT AIR OU SOL (r '/EX._RIEUR 9 Note: Acid Protection If acid-washing the masonry around the stove,protect the stove surface with an acid-proof cover. Fresh Air Inlet Unless there is deemed to be sufficient ambient leakage of air Into the room via doorways,windows and the like,a dedicated fresh air inlet will be needed.This inlet should have 2 square inches(1250 square mm)of free air space.This is particularly important where the room is well sealed,or where an extractor hood or ventilation system disturbs the natural air pressure Such an inlet should not be on a wall that is usually subject to negative pressure from normal wind pattern.Avoid placing the inlet directly across the room from the stove,thus causing a cold air draft. io