Loading...
HomeMy WebLinkAbout43849-Z �Q�OSUFF�t'fcoG, Town of Southold 7/16/2019 P.O.Box 1179 N Tf 53095 Main Rd qy� �a �sSouthold,New York 11971 t.'12ytYlf� CERTIFICATE OF OCCUPANCY No: 40503 Date: 7/16/2019 TMS CERTIFIES that the building DECK Location of Property: 300 Bennetts Pond Ln, Mattituck SCTM#: 473889 Sec/Block/Lot: 113.-13-4 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/24/2019 pursuant to which Building Permit No. 43849 dated 6/11/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: DECK ADDITION TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Bailey,Edward&Sweda,Debra of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. PLUMBERS CERTIFICATION DATED tho ' ed g ature Tx TOWN OF SOUTHOLD ' o�g�FFO(�-co ed i BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 43849 Date: 6/11/2019 Permission is hereby granted to: Bailey, Edward 300 Bennetts Pond Ln Mattituck, NY 11952 To: construct deck addition to existing single-family dwelling as applied for. At premises located at: 300 Bennetts Pond Ln, Mattituck SCTM # 473889 Sec/Block/Lot# 113.-13-4 Pursuant to application dated 5/24/2019 and approved by the Building Inspector. To expire on 12/10/2020. Fees: SINGLE FAMILY DWELLING -ADDITION OR ALTERATION $364.00 CO -ADDITION TO DWELLING $50.00 Total: $414.00 Buildin spector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and"pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. -A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 / Date. New Construction: Old or Pre-existing Building: (check one) � Location of Property: House No. Street Hamlet Owner or Owners of Property: ,[�Cc/ /� Suffolk County Tax Map No 1000, Section / , Block Lot Subdivision / 2 Filed Map. Lot: Permit No. L{ / Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: / Request for: Temporarytificate Final Certificate: (check one) Fee Submitted: $ App c nt Signatur BOE 30(/Tyo f # TOWN OF SOUTHOLD BUILDING DEPT. `yco 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] UNDATION 2ND [ ] INSULATION [ FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: V,)Ooyj> 4 �y 5t/,O- DATE INSPECTOR/wf��—1 A FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (1ST) 00 • H .................................... FOUNDATION (2ND) rro • O ROUGH FRAMING& PLUMBING H a INSULATION PER N.Y-. y STATE ENERGY CODE 1� O 10 zv� FINAL ADDITION4L CO NTS Ila / • .Zyy • N • d b ,H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey Southoldtownny.gov PERMIT NO. U Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined `� I ,20 ll Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: Approved 20A Mail to: Disapproved a/c Phone: 1'406'" -� Expiration D '20 Building Inspector PPLICATION FOR BUILDING PERMIT DDate Z_ 20 MAY 2 4 2019 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 771,' sets of lans,` ekt plair l to scale.Fee according to schedule. RGU U&I-ation of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. , c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Sign re of applica or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee agent, architect, engineer, general contractor, electrician, plumber or builder ,OCL ,6,e Au,,2 451L1,64- �0 G6AI724_�-_76,e Name of owner of premises 4-4, 1d, A,E,6�jC� (As A the tax roll or latest deed) If lican Yc Vor ion, signature of duly authorized officer ( me and tit of corsporaie-`o�fic'er) Builders License N iW -6:390; ' ir_• Plumbers License No: .• ``" •1, Electricians License No. " Other Trade's License No. 1. Location of land OD which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section I J Block 13 Lot 1 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises aYid intended use and occupancy of proposed construction: a. Existing use and occupancy &Ale b. Intended use and occupancy 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Workj►7r�/�3� (Description) 4. Estimated Cost,6� ® Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use.- 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth :Height Number of Stories 8. Dimensions of entire new construction: Front Rear .n- -Depth Height Number of Stories , ` ;� 9. Size of lot: Front Rear Depth e °� ` l 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 1/ 13. Will lot be re-graded? YES NO /Will excess fill be removed from premises?YES NO t/ 14.Names of Owner of premises?ALA�rZ Addres0iV, &A') Phone No,0/-a-77-3S,32 Name of Addres Ar--'&%wA(� R9. Phone No Name of Contractor r Izlsl Address MoD &,yj, Pn-05 hone No.631-406-P ZS-3 L,E'1 16,,14W4T x. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO—,(� * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF SUFFol>!4) being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the 1ii4iE D. 8 (Contractor, Agent, Corporate Officer, etc.) Notary public,state 01 14— No.OIBU6185W is s Suffolk County� �((���Q �� of said owner or owners, and is duly authorized to perform or have performed the PtbipPitt rdkVa�rde this application; that all statements contained in this application are true to the best of his know � enan belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of 20 1 ( L GGrw Notary Public Signatur of Applicant IVScott A. Russell tZEC°Su�� �hCA�1�A�(G�)EI��lUE1��C'SUPERVISOR �SOUTHOLDTOWNHALL-P.O.Box 1179 � � Town of Southold 53095 Main Road-SOUTHOLD.NEW YORK 11971 O� CMP-TER 236 - STORMWATER MANAGEMENT WORK SKEET (TO BE COMPLETED BY THE APPLICANT) DOES TMS PROJECT INVOLVE ANYOF THE FOLLOWING: (CHECK ALL THAT APPLY) Yes No ❑ A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑ . Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑ C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ❑ D ite preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑ E, ite preparation within the one-hundred-year floodplain as depicted on FIRM Map of any watercourse. ❑ F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Fenn to the Building Department wits your Building Permit Application. S.C.T.M. 1000 Date APPLICANT: (Property Owner,Deslgn�Pjrroofessional Agent,Contractor,Other) Dtstrlct NAME 6Section Block Lo[ A / e7 FOR BUILDING DEPARTMENT USE7ONLY—*v** Contact Information Reviewed By: - - — — — — — — — — Date Property Address /Location of Construction Work: — — — — — — — — — — — — — — — — — ��r Approved for processing Building Permit. El Stormwater Management Control Plan Not Required. ElStormwater Management Control Plan is Required. (Forlwai d to Engineering Department for Review) FORM 4 SMCP-TOS MAY 2014 RA SWEDA A D go ,w ES yF '9,0 �Oo POLE NI CoNc VIA POLE / 0-0 :.. = CON 53.6' MON. S\ 00 213 j:ps - - I i pp o; i p y _ WELL tJ�� 10. SAy: SPIKE O 5A _ - 3'w � 35.3' 2� <10 �cAO �N13 O� 0 •� p,�1 6' 6 S SET - SPIKE N.•IGXD=254.gxd—04&32015-09.�30AM--Scala i.s6Q SURVEYED FOR EDWARD BAILEY & DEBRA SWEDA PROPERTY LOCATED AT MATTITUCK g,0 AD LOT No. 10 MAP OT'S FI EDFJUNEN 2T 1970:OND FILE NO: 5483 STpKALiA TOWN OF SOUTHOLD fy SUFFOLK COUNTY. NEW YORK S.C.T.M. + 1000-113-13-4 AREA - 28.025 SF - 0.5434 AC SCALE: V-30' �a NOTESTHE EXISTENCE OF RIGHT OF WAYS. `j \ WETLANDS ANO/OR EASEMENTS OF RECORD �✓ 1F ANY. NOT SHOWN ARE NOT GUARANTEED, tSEXTION 7TE3 AI TEMHOW DR STATC TO THOS NLA L 16 n VIOLATION p•2$,�p,63 0• POLE �eecrlON vzsa of THE NBN YORK eTATE ErnEwnaH uHt MU OF THIS MM HAP MY SEARM THE LANG RIWYEYOAS W= Alf coot, 77 0 OR MItltSSW BEAL SWAN NOT OR COSIOERED TO BE A VAIO ME COPY. p0 •( �Q�ti1�� pp MCI. T: P�,•� OHARAHHTEES CA CERTIFICATI@S OSICATED NFAEOtH OWL RW ONLY TO 1{,9 THE FATRS011 FOR 00 THE SUiVkY SO PWARFO.AND ON HIS BMW TO THE TITLE COMPANY.OOYERHMFNTA AWW ANO LOM OBTMMON LISTED HERMN,ANO To THE A981OHM OF THE LOM I SMIMON. 9uARANtv9 OR COIRFICAnONS AM NOT TRAISFOtABLE TO AmiSM BSn1UTIONB BR SISSeOIO�JFT S • y 3� � � i/ � L1: SEPTIC SYSTEM LOCATION BY OTHERS 4 ?�. Spm 00 y dr.0 Lt O O 199,p 38.3' CERTIFIED TO: Q� EDWARD J. BAILEY DEBRA J. SWEDA vOt 0 SUFFOLK COUNTY NATIONAL BANK �s 9 FIDELITY NATIONAL TITLE INS. CO. 0 1',pn apt SURVEYED BY: BARYLSKI LAND SURVEYING 2320 MAIN ST. P.O. BOX 1302 1 NEWMAN VILLAGE CONDO. BRIDGEHAMPTON, NEW YORK (031-537-78441 23284 APRIL 17. 2015 izaza. i _aaw .t. b Q.� WIND LOAD PATH CONNECTION & CONSTRUCTION DETAIL DRAWINGS USE IS U 4LAWFUL USE THE FOLLOWING USP METAL CONNECTORS OR APPROVED EQUALS FOR PROPER WIND RESISTANT CONSTRUCTION. 4" X 4" POST W/ 2" X 2" 2" X 8" ACO LEDGER BOLTED EXISTING HOUSE WITHOU CERTIFICAT - FOLLOW MANUFACTURE'S RECOMMENDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY. BALUSTERS & CAP RAIL TO HOUSE FRAME WITH STRUCTURE TO REMAIN OF OCCUPAIC�Y "LEDGERLOK" SCREWS @ 16" 0. ; HANG D.J. FROM LEDGER WITH W 0-1 w o SIMPSON LU28 CONNECTOR W C'3 z M 4" MAX. 1" X 10" RIM BOARDFLOOR HEIGHT �� Z w w n CONTINUOUSLY AROUNDTX ' DECK BOARDS —'— — C7 a ra 4" MAX. 2" X 10" ACQ D.J. 16" O.C. W � P Z � w ] � 4" DIA. MAXIMUM M RETAIN STORM WATER RU dOFF o Z ° 4" DIA. MAXIMUM PROV. H4 CONNECTOR GRADE PURSUANT TO CHAPTER 236 w U " z GIRDER/HEADER o OF THE TOWN CODE. 2- 2" X 10" ACQ GIRDER—/ APPRO ED AS NOTED z BOLTED THRU POST 12 POST/COLUM DATE: B.P.# (0 Nnnnnnn ILL 4" X 4" ACQ POSTS ON FEE: 3 ,�� BY:1ON14 ?d'� 10" SONOTUBE W POURED ° / NOTIFY BUILDING DEPARTMENT AT CONCRETE FOOTING, FLARED a +s 765-1802 8 AM 70 4 PM FOR THE 20" X 8", 36„ BELOW GRADE W FOLLOWING INSPECTIONS: y r DECK/PORCH RAILING (TYPICAL ALL FOOTINGS) 1. FOUNDATION FOR POURED-CONCRE CONCRETE STAIR RAILING POST-TO-GIRDER/HEADER CONNECTION DECK SECTION 2. ROUGH - FRAMING & PLUMBING 1-112” SPACE USE MIN. (2) 1/2" DIA. MV. BOLTS WITH WASHERS AND NUTS SCALE: " '-0" 3. INSULATION � = 1 MINIMUM 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE HANDRAILS REQUIREMENTS OF THE CODES OF NEW POST YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORCOMPLY WITH LL CODES OF POST NEW YORK STAT & TOWN CODEcl AS REQUIRED ANM CONDITIONS 0- BALUSTERS RIM/DECK JOIS4 ° QV , qGOPEN BALUSTER ATTACHED TO WALL ° CONCRETE PIER � T I I Ir+ OAR O HANDRAIL CONNECTION PROVIDE 4" POURED CONCRETE ` EES ALL HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH PAD UNDER STAIR STRINGERS; OF THE STAIRS. HANDGRIP PORTION OF ALL HANDRAILS POST-TO-DECK CONNECTION VERIFY EXACT LOCATION IN FIELD 1'-4" 2- 2" X 10" ACQ GIRDER SHALL NOT BE LESS THAN 1-1/4" NOR MORE THAN 2" IN _ _ 4" X 4" ACQ POSTS ON CROSS SECTIONAL DIMENSION, OR THE SHAPE SHALL USE MIN. (2) 1/2" DIA. GALV. BOLTS WITH WASHERS AND NUTS DECK POST FTG. CONNECTION 10 SONOTUBE POURED PROVIDE AN EQUIVALENT GRIPPING SURFACE LOCATION USP NUMBER DESCRIPTION APPLICATION _ % i CONCRETE FOOTING, PROVIDE 4" POURED CONCRETE 04 POST PAU44 OR WE44 POST / BEAM ANCHOR APPLY TO EACH FOOTING 1'-0" 36" BELOW GRADE PAD UNDER STAIR STRINGERS; N (TYPICAL ALL FOOTINGS) VERIFY EXACT LOCATION IN FIELD +4 FLASHING TUCKED UNDER TOP PIECE OF SIDING AND o LAPPED OVER FIRST CONTIN. s'-11" 5'-10" 7'-4 1/2" STAIR TREAD PIECE OF SIDING BELOW "LEDGERLOK" SCREWS o DBL RIM BOARD CONNECTED TO BLDG. 016" OC U JOIST UI � j STRINGER O m FLOOR FRAMING 2x10 DECK JOIST x I - Y GIRDER a'-o" a'-o"— a'-o" 4'-4 112"— _ BLOCKING JOIST HANGER I w U STRINGER TO DECK/PORCH CONNECTION o V-0" RIM JOIST JOISTS OVER HEADER/GIRDER o 11 11 �x Jx6 DECK BOARDS (D } m LOCATION USP NUMB DESCRIPTION APPLICATION JOIST TO GIRDER/HEADER I RT10 ITYDOWN ANCHOR ICONNECT TO EACH JOIST DECK LEDGER CONNECTION =4 " O a M 3 X > Q N � 0 2" X 10" ACQ LEDGER BOLTED r 0 TO HOUSE FRAME WITH 5" . DECK & PORCH NOTES: 'HANDG ERLOKD.J. FROMREWS L DGR WITHO C 2. Unless otherwise noted, all framing material to be #1 ACQ pressure treated lumber. SIMPSON LU28 CONNECTOR A I fasteners, hangers and anchors to be galvinized or stainless steel. I LLJ Z �- 2). Girders for deck joists to be bolted or anchored to each post or pier with washers and nuts. 10'-7" —3'-0" - O Z Girders concrete piers shall be anchored with proper steel connectors anchored CLIMATIC & GEOGRAPHIC DESIGN CRITERIA DECK P LAN °- into concrete with a minimum 1/2" dia x 7" long anchor bolt with washers and nuts. GROUND WIND SEISMIC FROST WINTER ICESHIELD O— c:) N 3). Posts support' irders shall be anchored to a 12"x12"x12" thick concrete footing FLOOD „ -' pp g I SNOW SPEED DESIGN WEATHERING LINE TERMITE DECAY DESIGN UNDERLAYMEN HAZARDS SCALE: = 1'-0" 0 Use a minimum 1 2" dia x 7" long anchor bolt with washers and nuts. Footings Shal LOAD (MPH) CATEGORY DEPTH TEMP. REQUIRED » I--- be 4 ft. below grade. cr� 0 0 20 LBS 140 B SEVERE 3 FT. MODERATE SLIGHT T 11 NA - ~ = z 4). Deck joists to have blocking at 8'0 o.c.. TO HEAVY MODERATE n W o F 5). A minimum of 10 inch flashing shall be installed between the building and ledger. z UJ Ledger to be fastened to building with 1/2" dia. bolts with washers and nuts at 16" o.c. W z 0 vi Z Li 0 6). Concrete piers shall be a minimum 6" above grade. m (n F 7). All joists to be supported with hangers and anchors. Each Joist shall also be anchored Q Li to girder(s). M 0 W O z w p { rn °' z Z> / z w I0 W z m �' a