Loading...
HomeMy WebLinkAbout43433-Z ���g�EFOt�coGy Town of Southold 6/10/2019 0 E.O.Box 1179 C00. 53095 Main Rd �'ffjo� yap Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 40440 Date: 6/10/2019 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 3850 Camp Mineola Rd, Mattituck SCTM#: 473889 Sec/Block/Lot: 123.-5-18 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 1/25/2019 pursuant to which Building Permit No. 43433 dated 1/31/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: roof-mounted solar panels on existing single-family dwelling as applied for. The certificate is issued to Nardolillo,Louis&Erin of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 43433 5/13/2019 PLUMBERS CERTIFICATION DATED 4;0�_ Authorized Signature gont�, TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 43433 Date: 1/31/2019 Permission is hereby granted to: Nardolillo, Louis & Erin 420 Bray Ave Laurel, NY 11948 To: install roof-mounted solar panels on existing single-family dwelling as applied for with flood permit. At premises located at: 3850 Camp Mineola Rd, Mattituck SCTM # 473889 Sec/Block/Lot# 123.-5-18 Pursuant to application dated 1/25/2019 and approved by the Building Inspector. To expire on 8/1/2020. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Flood Permit $100.00 Total: $300.00 Bui ding Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. 1/22/19 New Construction: Old or Pre-existing Building: X (check one) Location of Property: 3850 Camp Mineola Road Mattituck House No. Street Hamlet Owner or Owners of Property: LOUIS Nardolillo p Suffolk County Tax Map No 1000, Section 123 Block 5 Lot 18 Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ 50 Appl cant Signature pF SOUTy®lo Town Hall Annex Telephone(631)765-1802 54375 Main Road CO- � Fax(631)765-9502 P.O.Box 1179 ® �� roger.richert( -town.southold.ny.us Southold,NY 11971-0959 c®unm�� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Louis Nardolillo Address: 3850 Camp Mineola Road city,Mattituck st: New York zip: 11952 Building Permit* 43433 Section: 123 Block: 5 Lot: 18 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Green Logic License No: 43858-ME SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Ll Switches Twist Lock Exit Fixtures TVSS Other Equipment: 11,520 KW Roof Mounted Photovoltaic System to include: 32-SP-360 Panels with Micro Inverters, AC Combiner Panel and AC Disconnect. Notes: Inspector Signature: Date: May 13, 2019 0-Cert Electrical Compliance FormAs i OF SO�Th°� * # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ` [ ] FOUNDATION 1ST [ ] ROUGH PLBG. ( �-7 [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE INSPECTO J A M E S J. S T © UT A R C H I T E C T & Assoc. 2 G REG L ANE E AST NORTHP ORT N. Y. 631 - 8 58 8388 Post Installation Letter May 21, 2019 RE: Nardolillo Residence 3850 Camp Mineola Road Mattituck, NY 11952 To Whom It May Concern: This letter is to confirm that as of this date May 21,2019,I,James J Stout, NYS license 021633 have personally inspected the placement and installation of the roof top solar panels at the above listed address. All of the solar panels have been installed as per manufacturer's guidelines and specifications. The racking system design and installation complies with the 2017 NYSRC and 2017 NYSUCS building code and all related provisions. The installation of panels was done as per plan. Thank you for your cooperation in this matter. James J. Stout Architect FD) L' �. JUN 1 0 2019 Tp F 1 xu s � 0NES i FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION (IST), ------------------------------------ 'FOUNDATION (2ND) - z ROUGH FRAMING& PLUMBING CA ° F ®' ' O ' INSULATION PER N,Y. STATE ENERGY CODE FINAL ADDITIONAL CO TS _.I1 3/ 0 M = tel© rn C 1 �• H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 . Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. LCheck Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined ,20—tt Storm-Water Assessment Form Contact: Approved ,20 Mail to: GreenLogic LLC Disapproved a/c 97 North Sea Road,Southampton,NY 11968 Phone: 631-771-5152 Expiration ,20 y- f'I" itll s:' � Inspector t.., APPLICATION FOR BUILDING PERMIT PV1 JAS! 2 5 2019 Date January 22 2019 { INSTRUCTIONS r" a. This.application MAOI'be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale. Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c. The work covered by this application may riot be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept-on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months. Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit .� authorized inspectors on premises and in building for necessary inspections. GreenLogic LLC (Signature of applicant or name,if a corporation) 97 North Sea Road Southampton, NY 11968 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Contractor Name.of owner of premises Louis Nardolillo (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer A (Nalt and title of corpor to officer) Builders License No. 40227-H Plumbers License No. N/A Electricians License No. 43858-ME Other Trade's License No. N/A 1. Location of land on which proposed work will be done: 3850 Camp Mineola Road Mattituck House Number Street Hamlet County Tax Map No. 1000 Section 123 Block 5 Lot 18 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single family dwelling b. Intended use and occupancy Single family dwelling 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other WorkRoof mounted solar electric system (Description) 4. Estimated Cost $49,283 Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase 4/3/17 Name of Former Owner Norman Wamback 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO X 13. Will lot be re-graded?YES NO X Will excess fill be removed from premises?YES NO 3850 Camp Mineola Rd 14.Names of Owner of premises Louis Nardolillo Address Mattituck, NY Phone No. Name of Architect James Stout Address 2 Greg Ln, E. Northport phone No 631-858-9388 Name of Contractor GreenLogic LLC Address 97 North Sea Road Phone No. 631-771-5152 Southampton, NY 11968 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO x * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C.PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO x * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO x * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk ) 'Nesim Albukrek being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the Contractor (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me thi ZZ day of 2019 Notary Public BARBARA A.CASCIOTTA 'r!�ignature of Applicant Notary Publiq State of New York No.01-CA4894969 Qualified in Suffolk County Commission Expires May 11,20119 r APPLICATION � ' PAGE 1 of 4 TOWN OF SOUTHOLD FLOODPLAIN DEVELOPMENT PERMIT APPLICATION i �i D 'niis form is to be filled out in duplicate. �_} FEB - 42019 SECTION 1 GENERAL PROVISIONS (APPLICANT to read and sign): 1. No work may start until a permit is issued. 2. The permit may be revoked if any false statements are made herein_ TOWN OF SOUT11G2,D 3. If revoked, all work must cease until permit is rc-issued. 4. Development shall not be used or occupied until a Certificate of Compliance is issued. 5. The permit will expire if no work is commenced within six months of issuance. 6. Applicant is hereby informed that other permits may be required to fulfill local, state and federal regulatory requirements. 7. Applicant hereby gives consent to the Local Administrator or his/her representative to make reasonable inspections required to verify compliance. 8. I,THE APPLICANT,CERTIFY THAT ALL STATEMENTS HEREIN AND IN ATTACHMENTS TO _ THIS APPLICATION ARF,TO THE BEST OF MY KNOXVLEDGE,TRUE AND ACCURATE. (APPLICANTS Sf(,*ATURE) MmzzzDATE 1/31/19 SECTION 2 PROPOSED DE LOPMENT(Tb be completed by APPLICAlN NAME _ ADDRESS TEL PH NE APPLICANT Louis Nardolillo 3850 Cam Mineola Road. BUILDEIGreenLogic LLC 97 North Sea Rd, Southampton, NY 1 J 968 63 1- - E]AREEt James J. Stout 2 Greg Ln, E NorthportNY Q13 11 01 PROJECT L(,ZCATION: To avoid delay in processing the application. please provide enough information to easily identify the project location. Provide the street address, lot number or legal description (attach) and, outside urban areas, the distance to the nearest intersecting road or well-known landmark. A sketch attached to this application showing the project location would be helpful. Solar panels on roof FDP(93) APPLICATION PAGE 2 OF C —~- DESCRIPTION OF WORK (Cbeck all applicable boxes) A. STRUCTURAL- DEVELOPMENT ACTIVITY STRUCTURE_ TYPE O New Structure ;J Residential (1-4 Family) ❑ Addition ❑ Residential (More than 4 Family) fR Alteration ❑ Non-residential (Floodprooring? ❑ Yes) 0 Relocation 0 Combined Use (Residential & Commercial) ❑ Demolition P ❑ Manufactured (Mobile) Home (In Manu- C3 Replacement factured Home Park? ❑ Yes) ESTIMATED COST OF PR07ECT s 49,283 B. OTHER DEVELOPMENT ACTIVITIES: O Fill ❑ Mining 0 Drilling O Grading ❑ Excavation (Except for Structural Development Checked Above) ❑ Watercourse Alteration (Including Dredging and Channel Modifications) l3 Drainage Improvements (Including Culvert Work) ❑ Road.Street or PrUge Construction O Subdivision (New or Expansion) ❑ Individual Water or Ser System ❑ Other (Please Specify)' Roof mouted sol After completing SECTION 2, APPLICANT should submit form to Local Admuustrator for review. LE2CTION 3 FLOODPLAIN DETERMINATION fTo be comalcicd v LOCAL ADMINISTRATOR) The proposed development is located on FIRM Panel No. Dated The Proposed Development: ❑ Is ►Nl E located in a Special Flood Hazard Area (Notify the applicant that the application review is complete and NO FLOODPLAIN DEVELOPMENT PERMIT IS REQULRED)' 0 Is located in a Special Flood Hazard Area. FIRM tone designation is 100-Year flood elevation at the site is: Ft. NGVD (MSL) O Unavailable Cl The proposed development is located in a floodway. FBFM Panel No. Dated ❑ Sec Section 4 for additional instructions SIGNED DATE APPLICATION PAGE 3 OF a SECTION 4 ADDtTIQNAL INFORMATION REQUIRED (To be completed by LOCM.ADMINISTRATQR) The appbcanl must submit clic documents checked below before the application can be processed Cl A site plan shovnng the location of all existing structures, water bodies, adjacent roads, lot dimensions and proposed development. ❑ Development plans, drawn to scale, and specifications,including where applicable:details for anchoring structures,proposed elevation of lowest floor(including basement), types of water resistant materials used below the first floor,details of floodproofing of utilities located below the fust floor and details of enclosures below the first floor. Also ❑Subdivision or other development plans (If the subdivision or other development exceeds 50 lots or 5 acres, whichever is the lesser, the applicant must provide 100-year flood elevations if they are not othcrwisc available). ❑ Plans showing the extent of watercourse relocation and/or landform alterations. ❑ Top of new fill elevation Ft. NGVD (MSL). ❑ Fioodproofuig protection level (non-residential only) Ft.'NGVD (MSL). For y, floodl�roofed structures, applicant must attach certification from registered engineer or architect. ❑ Certification from a registered engineer that the proposed activity in a regulatory floodway will not result in an increase in the height of the 100-year flood. A copy of all data and calculations supporting<t-his finding must also be submitted. ❑ Other: SECTION 5 PERMIT DETERMINATION (To be completed by LOCAL ABMINI51RATORI I have determined that the proposed activity. A.O Is B.O Is not M conformance with provisions of Local Law # , 19 The permit is issued subject to the conditions attached to and made part of this permit. SIGNED , DATE If BOX A is checked, the Local Administrator may issue a Development permit upon payment of designated fee. If BOX B is checked, the Local Administrator will provide a written summary of deGeioncies. Applicant may revise and resubmit an application to the local Administrator or may request a hearing from the Board of Appeals APPLICATION w _ PAGE 4OF4 APPEALS Appealed to Board,of Appeals? ❑ Ycs ❑ No Hearing date: Appeals Board Decuioo --- Approved? ,❑ Yes ❑ No Cooditions SECTION G• A_S-BUILT ELEVATIONS (To.be submitted by APPLICANT before Certificate of Compliance is issued The following information must be provided for project structures. This section must be completed by a registered professional engineer or a licensed land surveyor (or attach a certification to this application). Complete I or 2 below, 1. Actual (As-Built) Elevation of the top of the lowest floor,including basement in Coastal High Hazard Areas, bottom of lowest structural member of the lowest floor, excluding pilling and columns) is: Fr. NGVD (MSL). 2. Actual (As-Built) Elevation of floodproofmg protection is FT. NGVD (MSL). NOTE: Any work performed prior to submittal of the above information is at the risk of the Applicant. SECTION 7 COMPLIANCE ACTION (To be completed by LOCAL ADMINISTRATORI The LOCAL ADMINISTRATOR will complete this section as applicable based on inspection of the project to ensure compliance with the community's local law for flood damage prevention. INSPECTIONS: DATE BY DEFICIENCIES? OYES ❑ NO DATE BY DEFICIENCIES? ❑ YES ❑ NO DATE BY DEFICIENCIES? ❑ YES ❑ NO SECTION $ CERTiFICATE OF COMPLIANCE(To be cgmplatcd by LOCAL ADMINISTRATORI Certificate of Cooaplia.nce issued: DATE: BY: Attachment B SAMPLE CERTIFICATE OF COMPLIANCE for Development in a Special Flood Hazard Area TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE FOR DEVELOPMENT IN A SPECIAL FLOOD HAZARD AREA (OWNER MUST RETAIN THIS CERTIFICATE) PREMISES LOCATED AT: PERMIT NO. PERMIT DATE OWNERS NAME AND ADDRESS: CHECK ONE: O NEW BUILDING O EXISTING BUILDING O VACANT LAND THE LOCAL ADMINISTRATOR IS TO COMPLETE A. OR B. BELOW: A. COMPLIANCE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF - LOCAL LAW # , 19_ SIGNED: DATED: B. COMPLIANCE IS HEREBY CERTIFIED WITH THE REQUIREMENTS OF LOCAL LAW # , 19-, AS MODIFIED BY VARIANCE # DATED SIGNED: DATED- CIC(93) Scott A. Russell 'SII /r91 ST0IKMWA\T]E]K SUPERVISOR MANAGEMENT SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 Town of Southold CHAPTER 236 o STORMWATER MANAGEMENT WORD SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOES THIS PROJECT IN-VOLVE ANY OF T14E FOLLONVIN, (k 1 3 (CHECK ALL THAI' APPLY) Yes No 11 ® x® A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. ❑� B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ® 1 C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. ®El D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ® x� E, Site preparation within the one-hundred-year floodplain as depicted on.FIRM Map of any watercourse. ; ®E] F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes Lin-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature,Contact Information, Date,& County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above,please submit Two copies of a Stormwater!Management Control Plan and a completed Check ListForm_to the Building Department with your Building Permit Application. APPLICANTropertd Ovnec.Deaign Prores�ranal,Ag*nt,Carit�acu�r;C7ther}V S'C.7'M' *' 10�� Date uLairlCS 123 5 18 1 NAME. GreenLo G (Nesim Albukrekl Section Block Eat l — i f'OR BUILDING DLPAIt'I'MLN'r USL ONLY** 6 1-771-5152 C Contact lnfomtattam ' 'Tebpiwm Tumbm3 Reviewed By: ; - - — — — — — — — — — — — — — — — � Date: Properly Address/ Location of Construction Work: ! _ , — — — — — — — — — — — — — — — — Approved for processing Building Permit. s I ; 3850 Camp Mineola Road Storin-water,Management Control Plan Not Required. 3 Mattituck, NY - - — — — — — — — — — — — — — — — ® Stormwater Management Control Plan is Required. (Forwai d to Engineering Department for FORM*SMCP='ros MAY 2014 sof Sadly Town Hall Annex Telephone(631)765-1802 54375 Main Road P.O.Box 1179 G Q r0 er.richert at4`1Nn soutfio9d.n .11s Southold,NY 11971-0959 BUILDING DEPARTMENT i TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Barbara Casciotta Date: 1/22/19 r Company Name: GreenLogic LLC Name: Robert Skypala ' License No.: 43858-ME Address: 97 North Sea Road Southampton, NY 11968 Phone No.: . 631-771-5152 JOBSITE INFORMATION: (*Indicates required information) *Name: Louis Nardolillo *Address: 3850 Camp Mineola Road, Mattituc "Cross Street: *Phone No.: 631-834-2697 Permit No.: Tax-Map District: 1000 ection: 123- Block: 5 Lot: 18 *BRIEF DESCRIPTION OF WORK(Please Print Clearly) * Roof mounted solar electric system 11.520kW 32 SunPower SPR-X22-360-D-AC modules/micro inverters (Please Circle All That Apply) *Is job ready for inspection: YES NO Rough In Final Do you need a Temp Certificate: ES NO - - Temp Information(if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION B2-Request for Inspection Form GREENLOGIC° ENERGY January 23, 2019 Town of Southold Building Department Town Hall 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Please find attached a building permit application on behalf of the Louis Nardolillo who has engaged us to install a roof mounted solar photovoltaic (PV) electric system located at 3850 Camp Mineola Road, Mattituck, NY. In connection with this application, please find attached: p r_' [ 1i • Building Permit application JAN 2 5 2019 Le • A Storm Water Assessment Run-off Form • Certificate of Occupancy Application • Application for Electrical Inspection pp p • 2 Surveys of the Premises • 4 Engineer's Reports (2originals and 2 copies) • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200 ($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, 53aJaw Casdetta Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 ext. 117 GREENLOGIC LLC - www.Green Logic.com Tel 631.771.5152 Fax 631.771.5156 -SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd , Suite 3 200 S.Service Rd.,#106 -Southampton, NY 11968 Rosyln Heights, NY 11577 LG�GREENLOGIC° ENERGY January 31, 2019 D FEB - 4 2019 Town of Southold Building Department $= o Town Hall TOWN 53095 Route 25 Southold, NY 11971 Dear Building Inspector: Please find attached a floodplain permit application on behalf of the Louis Nardolillo who has engaged us to install a roof mounted solar photovoltaic (PV) electric system located at 3850 Camp Mineola Road, Mattituck, NY. In connection with this application, please find attached: • Floodplain Permit application • Updated Liability Certificate • Check for$100 Please let us know if you need anything else in connection with this application. Yours truly, 53m6ma emcioUa Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 ext. 117 GREENLOGIC LLC a www.GreenLogic corn Tel. 631.771 5152 Fax 631 771 5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd.,Suite 3 200 S Service Rd.,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 GREENL®GIC® ENERGY June 6, 2019 The Town of Southold Building Department 54375 Route 25 P.O. Box 1179 Southold, NY 11971 Re: Building Permit No.43433 Louis Nardolilo 3850 Camp Mineola Rd, Mattituck To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the solar electric system we installed at the above reference address. I have also enclosed as built plans as the layout changed slightly from original plans. Please arrange to send the Certificate of Occupancy and close out the building permit. Please let me know if you have any questions about the installation. Sincerely, 9644a soda = Barbara Casciotta �. Account Manager nD L; Barbara@Greenlogic.com 631-771-5152 Ext. 117 JUN 1 Q 2019 T. GREENLOGIC LLC ®www.GreenLogic.com Tel 631.771 5152 Fax. 631.771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd., Suite 3 200 S.Service Rd ,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 SO!/r�®! Town Hall Annex Telephone(631)765-1802 54375 Main Road y Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 ®I�00UNT`1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD June 6, 2019 Greenlogic 97 North Sea Rd Southampton, NY 11968 Re: Nardolillo, 3850 Camp Mineola Rd, Mattituck TO WHOM IT MAY CONCERN: The Following Items(if Checked)Are Needed To Complete Your Certificate of Occupancy: NOTE: Engineer's certification post installation letter required Electrical Underwriters Certificate A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Punning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. Final Storm Water Runoff Approval from Town Engineer BUILDING PERMIT —43433 — Solar Panels ............ 3�2 .-WX N tive' Office of Consumer Affairs Suffolk County Execu s VETERANS MEMORIAL HIGHWAY HAUPPAUGE,NEWYORK 11788 DATE ISSUED: 5/25/2006 Novl . 40227-H SUFFOLK COUNTY Home Improvement Contractor License This is to certifv that MARC A CLEAN doing business as GREEN LOGIC LLC having furnished the requirements set forth in accordance with and-subject to the provisions of applicable laws,rules and regulations of the County of Suffolk, State of New York is hereby licensed to conduct business as a HOME IMPROVEMENT CONTRACTOR,in the County of Suffolk. ................ Additional Bgsinesses 2 NOT VALID WITHOUT Df 1 IEPARTMENTAL SEAL AND A CURRENT CONSUMER AFFAIRS ID CARD t 11! Director Z DATE A CERTIFICATE OF LIABILITY INSURANCE 01/37/2019 DnYYY) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME- Brookhaven Agency,Inc. PHONE 631 941-4113 Fax 631 941-4405 128 Old Town Road,Suite CMaL AougEssm CustomerService@ brookhavena enc .com P.O.BOX 850 INSURERS AFFORDING COVERAGE NAIC# East Setauket NY 11733 INSURER A.- Southwest Marine&General Insurance Co. INSURED INSURER B: Merchants Preferred Insurance Co. GreenLogic,LLC INSURER c: First Rehab Life Insurance Co. 97 North Sea Rd,Suite 3 INSURER D: National Liability&Fire Insurance Co. Southampton NY 11968 INSURER E.- AGCS Marine Insurance Co. INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXPLTR LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A CLAIMS-MADE �OCCUR DAMAGE TO RENTED 100 000 X Contractual Liability X X GL201900012922 01/31/2019 01/31/2020 MED EXP(Any oneperson) $5,000 PERSONAL&ADV INJURY $1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER GENERAL AGGREGATE s2,000,000 POLICY JE� F7LOC PRODUCTS-COMP/OP AGG $2,000,000 OTHER, $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $1,000,000 B X ANY AUTO BODILY INJURY(Per person) $ OWNED SCHEDULED X X CAP1043565 08/11/2018 08/11/2019 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS X HIRED X NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY $ X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $1,000,000 A EXCESS LIAR CLAIMS-MADE X X UM201900007751 01/31/2019 01/31/2020 AGGREGATE $1,000,000 DED I I RETENTION 0 $ WORKERS COMPENSATIONX PER OTH- AND EMPLOYERS'LIABILITY ANY D OFFICERIMEM ER�EXCLUDEECUTIVE Y/❑N N/A V9WC857891 06/15/2018 06/15/2019 E L EACH ACCIDENT $1,000,000 (Mandatory in NH) E L.DISEASE-EA EMPLOYEE $1,000,000 If yes,des DESCRIPTION OF underribe OPERATIONS be o E L DISEASE-POLICY LIMIT $1,000,000 C NYS Disability D251202 04/11/18 04/11/19 Statutory Limits E Installation Floater/Property SML93076366 4115118 4/15/19 $250,000 $1000 Ded DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached N more space is required) Certificate holder is also named as Additional Insured. CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <> ©1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD CERTIFICATE OF LIABILITY INSURANCEDATE(MM/DD/YYYY) 01/2912018 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the Certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Brookhaven Agency,Inc. Brookhaven Agency,Inc. PHONE 631 941-4113 Fax Hole 631 941-4405 128 Old Town Road Suite C E-�L brookhaven.agency@verizon.net PO Box 850 PRODUCER East Setauket NY 11733 INSURERS AFFORDING COVERAGE NAIC ti INSURED INSURER A. HDI Global Insurance Co. Greenlogic,LLC INSURER B. Merchants Preferred Insurance Co. 97 North Sea Rd,Suite 3 INSURER C: First Rehab Life Insurance Co. Southampton,NY 11968 INSURER D.-Endurance American Insurance Co. INSURER E: AGCS Marine Insurance Co. INSURER F: National Liability&Fire Insurance Co. COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS rINSR TYPE OF INSURANCE AODL SUER imaPOLICY NUMBER POLICY EFF (POLICY EXP LIMITS ` NYYYI GENERAL LIABILITY EACH OCCURRENCE $1,000,000 X COMMERCIAL GENERAL LIABILITY X X EGGCR000076918 01/31/18 01/31/19 DAMAGE TO RENTED $100,000 CLAIMS-MADE ®OCCUR MED EXP(Any oneperson) $5,000 X XCU PERSONAL&ADV INJURY $1,000,000 X Contractual Liab I GENERAL AGGREGATE $2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER PRODUCTS-COMP/OP AGG $2,000,000 POLICYFX PRO LOC $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT B X ANY AUTO x CAP1043565 8/11/17 8/11/18 (Ea accident) $1,000,000 BODILY INJURY(Per person) $ ALL OWNED AUTOS BODILY INJURY(Per accident) $ SCHEDULED AUTOS X HIRED AUTOS PROPERTY DAMAGE $ Per accident) X NON-OWNED AUTOS $ X UMBRELLA LIAR X OCCUR EACH OCCURRENCE $1,000,000 D EXCESS LUM CLAIMS-MADE EXC30000250901 1/31/18 1/31119 AGGREGATE $1,000,000 DEDUCTIBLE $ RETENTION 0 $ WORKERS COMPENSATION X I WC STATU- I IOTH- AND EMPLOYERS'LIABILITY F ANY PROPRIETOR/PARTNER/EXECUTIVE❑ N/A V9WC857891 6/15/17 6/15118 E L EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED? (Mandatory in NH) EL DISEASE-EA EMPLOYEE $11,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below EL DISEASE-POLICY LIMIT $1,000,000 C NYS Disability D251202 4/11117 4111/18 Statutory Limits E Installation Floater/Pro erty MX193076366 14/15117 4/15/18 $300,000 $1,000 Ded DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more space is required) CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <NSZ> ©1988-2009 ACORD CORPORATION. All rights reserved. ACORD 25(2009/09) The ACORD name and logo are registered marks of ACORD YORK Workers' CERTIFICATE OF 4 STATE Board Compensation NYS WORKERS' COMPENSATION INSURANCE,COVERAGE B 1a.Legal Name&Address of Insured{use street address only 1b.Business Telephone Number of Insured Greenlogic LLC; 631-771-5152q 97 North Sea Rd Suite 3 Southampton NY 11968 1 c.NYS Unemployment Insurance Employer Registration Number of Insured i Work Location of insured(Onlyrequired ifcoverage is specifically limited to 1d.Federal Employer identification Number of Insured or Social,Security certain locations in New York State,i.e.,a Wrap-Up Policy) Number 203801104 i 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Carrier {Entity Being Listed as the Certificate Holder} National Liability&Fire Ins Co Town of Southold 53095 Route 25 3b.Policy Number of Entity Listed in Box"ia" Southold NY 11971 V9WC857891 3c.Policy effective period 06115/2018 to 0611512019 3d.The Proprietor,Partners or Executive Officers are 0 included.(Only check box if all partners/officers included) ❑R all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated',above in box"3"insures the business referenced above in box"1a"for workers' compensation under the New York State Workers"Compensation Law,(To use this form,New York(NY)must be listed under f fem.:3...A- on the INFORMATION PAGE of the workers'compensation Insurance policy). The Insurance Carrier or its licensed agent trill send this Certificate of Insurance to the entity listed above as,the certificate holder in box"2". Will the carrier notify the certificate holder within 10 days of a policy being cancelled for non-payment of premium or within 30 days if cancelled for any other reason or if the insured is otherwise eliminated from the coverage indicated on this certificate prior to the end of the policy effective period? ®YES [jN6 This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any'rights or responsibilities beyond those contained'in the referenced policy. This certificate may be used as evidence of a Workers'-Compensation contract of insurance only while the underlying.policy is in effect, Please Note:Upon cancellation of the workers'compensation policy Indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder vaith a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the, mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,I certify that.ham an authorized representative or licensed agent of the insurance carrier referenced above and that the named insured has the coverage as depicted on this form. Approved by: Nicholas Zulkofske (Print name of authorized representative or licensed agent of insurance carrier) Approved b� ' , (Sign Lure} {Octel Title:Authorized Agent Telephone Number of authorized representative or licensed agent of insurance carrier: 631-941-4113 Please Note:Only insurance carriers and their licensed agents are authorized to issue,Form C-105.2.Insurance brokers are NOT authorizedlo issue it. C-105.2(9.15) w+",v.Nvcb.ny.gov Workers' Compensation Law Section 57. Restriction on Issue of permits and the entering Into contracts unless compensation Is secured. 1. The head of a state or municipal department, board, commission or office authorized or required by law to issue any permit for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, and notwithstanding any general or special statute requiring or authorizing the issue of such permits, shall not issue such permit unless proof duly subscribed by an insurance carrier Is produced in a form satisfactory to the chair, that compensation for all employees has been secured as provided by this chapter. Nothing herein, however, shall be construed as creating any liability on the part of such state or municipal department, board, commission or office to pay any compensation to any such employee if so employed. 2. The head of a state or municipal department, board, commission or office authorized or required by law to enter into any contract for or in connection with any work involving the employment of employees in a hazardous employment defined by this chapter, notwithstanding any general or special statute requiring or authorizing any such contract,shall not enter into any such contract unless proof duly subscribed by an Insurance carrier is produced in a form satisfactory to the chair,that compensation for all employees has been secured as provided by this chapter. C-105.2(9-15)REVERSE ]'� 4 � 5 ice of Consumer Affairs Suffolk County Executive's Off WWI J T, DA12/10/2007 ` 1�t ISUFFOLK COUNTYT ElectricianMaster License 1 This is to certify that ROBERT J SKYPALA doing businessGREENLOGIC LLC f/ C�- Countyhaving given satisfactory evidence of competency,is hereby licensed as MASTER ELECTRICIAN in accordance with and subject to the provisions of applicable laws,rules and regulations of the of • of • Additional Businesses /f `\ ?/ ! i ANDACURRENT F AFFAIRSCONSUMER 11)CARD , Director �`� • �'`�• i>���,\ �'��,��� '//'\�'' ���� . ;�. 'f, ���..�I�1�` 1, <'�� l• p> 1,/\,\ -�� !; �'��.� „ �l'�'� /1'`\ ��.; •/l�\ SURVEY OF PROPERTY SITUATE MATTITUCK TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK CERTI�`(TO: r— LOLUS A. NARDOLILLO. 0 20' ERIN A. NARDO LI LLD. SCTM# 1000-123-5-18 FIDELITY NATIONAL TITLE INSLtRANCE S ERV I CES, LLC. AREA= 12,701 Sq.ft. 0.29 Acres. CITIZENS gANI- Nit, ISAOA, ATIMA. ■ =concrete monument found NOW OR FORMERLY NOW OR FORMERLY JACQUELINE M FEDYNAK MARGARET M BERGAMINI RAYMOND E.FEDYNAK ROBERT J BERGAMINI CHARLES CAINeav°e stk fen MARY CAIN - 0 8's 0.5-s N 85010'00" E 50.00' N 85015'00" E 50.00' 10' 01 1 roof _ _ _ _ _ _ _ _ _ _ _ _ —A—A— _ save 0 3's stk fen V stockade fence 1 7 08'e 03'w 1-' 17's °0.2'w o frame 1 19 e shed I , ��F 10 3' frame i a3 19.11 oQ a �0 garage Q hang deck lean-to m I 0'e m W. 0 P 182' 5 of save 0 m0 , I save g e F{J h - - - , ( J 07'wl to g sed w n I I I I O 12 3' m 1 slate&concrete I I I I Q 4' I patio I I I - hi °o �, � I �a ` bock I I m D o ste s wood i arrerag � 0.5'w rste s lm 242 18.8' 3 0 I 2p� 0 37.0' 20.0' 'm I �mz DDO rn mm0 �M� r, ofov r I mZ9 mrno ,, op n I 5immm Dn root)ov r I - m .� con ree Z Z A 12.1' 2-stor}/ ,+, ps H I < f frame house N sepso 8 co 3 rn m O. I F 122' I � I rad road ad f o 0.3'e Ln y 44.6' 24 3' W 1 18.8' 07' m a Seps , I I '7 slate wales; v y 167n, 1 I I I j 'o� 86.52. / T I 'rail road Les mon hoe n&s 2 0 3 e 103.62, I I s 70"OeTi C� A Ea �N�ADDD�,ro MM—UW nAvaATwNae c�nNrmaocrawrDiasrATeuw CORDS OF TIB SUNV¢Y YAF NOt BPMDIG THC LW 0 9rtiV¢YOFS PL®6EAL OR E10056®6FIL 61UIL NOT DE CONSIOED®TO DE AVAW COP!OUARANN£90RCERLDIGTION9ppi0AlEDHEREON 61 W L W IN OSY TO THE PED9d.iM W11tl1 TXE W NYEY 6 PNEPAf6D /fdl W MB B@WFlOT1ET111E001RM11'.004FAMEfiTKAOENCI AlA N3mDq MBNNNgNlB1EOM[I¢ON,IIm TOT�A56AI J OFTNEIFTDWO WSf(NION OVAIUNIEESOR[BTRIGTON9Ai@ W T TIANSFT/HIG TO I➢Of IIDNN.DSOIOIION9Oq SN6g W ENF JOHN GALLACHER DUIEWEIEED.FA6EIENISAHD.ON EUESOHFADEDTHDDTND9 IEOONDFDON Ff+a6F.4A 11ETD¢OFT¢SIFVEYIMEb5H1W aME.w.ImlEaxmwTaDTwlaurDBroTD.THmFTmr LAND SURVEYOR wfF„D®TOd1OEi1EERECIIWKFEN=PETA WAUA 59 FLORENCE DRNE rous.ATws MINDNOARP D,ADDmousroewlns+cDAND OTNEn MANORVILLE N.Y.11949 NON-0DbIElYEOF EAS01Q1R ORPXW I6OFw11Y.VfFLIDgTH15 IA01fRIY THELOGTgfl9OFElSF1@ASORMNRLFWAY6 roNEa"°�°" SURVEYED: JANUARY 30, 2017 (631)-874-0400 C�- APPR VED AS NOTED DATE: B.P.#- RETAIN STORM WATER RUNOFF T FEE: BY: f 'PURSUANT TO CHAPTER 236 NOTIFY BUILDING DEPARTMENT AT OF THE TOWN CODE. 765-1802 8 AM TO 4 PM FOR THE K FOLLOWING INSPECTIONS: 1. FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH - FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST ELECTRICAL BE COMPLETE FOR C.O. INSPECTION REQUIRED ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES C)r= NEW YORK STATE & TOWN CODE` FLOOD ZONE- ILL-AS REQUIRED AND CONDITIONS O+- GoMy vir (-,VA TEIR148 � T WN 7RA �L t SQP4=5;@�{dI QARD SeUTttB I6WN-TUTEES _ RY TEG - OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY J A M E S J. S TOUT A RCHITEC --T & Assoc . 2 GREG LANE EAST NORTHPORT N. Y. 631 — 8 58 9388 Letter of Certification January 14, 2019 Nardolillo Residence 3850 Camp Mineola Road Mattituck, NY 11952 To Whom It May Concern: I,-James J. Stout, registered architect NYS license number 021633 would like to submit the following. I have inspected and analyzed the roof structure at the above- mentioned address and have determined the structure and the panel attachment to be adequate to support the new additional load imposed by the proposed solar panel system and complies with the 130-mph wind design load as 2017 New York State Uniform Code (2017 NYSUC), 2017 New York State Residential Code(2017 NYSRC) = (2015 International Residential Code(2015 IRC) (2nd Printing) and 2017 New York State Uniform Code Supplement(2017 NYSUCS) as well the Long Island Unified Solar Permit Initiative (LIUSPI) and the 2014 National Electric Code NFPA 701 2014 National Electric Code, and the ASCE 7-10. The existing 2"x 8" @ 16"o.c. roof rafters will provide the required support. Thank you for your understanding in this matter. James J. Stout Architect ED J.STD �F it e� GREENLOMPCO ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#A: Total System Size:11.520kW Array Size:3.600kW 1 circuit of 10 on a 20A breaker Azimuth:170° Pitch:22° Monitoring System: Al SunPower Panel/Array Specifications: Panel:SPR-X22=360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:30'10"X 10'5" Surface: -- Magic#:Invisimount Legend: ® 10 SunPower 360W Panels ® SunPower Invisimount Rad 32 Eco-Fasten Quik Feet g 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: E.D ARO sr �n w n Drag By:MA Drawing#1 of 11 Date:1/15/2019 REV:A e Drawing Scale:3/16"=1.0' "ccGREENLOSECO ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#A: Total System Size:11.520kW Array Size:3.600kW 1 circuit of 10 on a 20A breaker Azimuth:170° Pitch:22° Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X22-360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:30'10"X 10'5" Surface:33'3"X 14'3" Magic#:Invisimount Legend: ® 10 SunPower 360W Panels ® SunPower Invisimount Rail 32 Eco-Fasten Quik Feet 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: _D ARSI- 21635 G f 1 T 21 6 3 5 L c Drawn By: A D #2 of 11 Date:1/15/2019 REV:A r Drawing Scale:3/16"=1.0' EENLOQO ° ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#A: Total System Size:11.520kW Array Size:3.600kW 1 circuit of 10 on a 20A breaker Azimuth:170° Pitch:22° Monitoring System: Al SunPower Panel/Array Specifications: Panel:SPR-X22-360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:30'10"X 10'5" Surface:33'3"X 14'3" Magic#:Invisimount Legend: ® 10 SunPower 360W Panels 737 SunPower Invisimount Rail 32 Eco-Fasten Quik Feet B 2x8"Douglas Fir Rafter 16"O.G. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: ED 'ARG' Drawn By:MA Drawing#3 of 11 Date:1/15/2019 REV:A Drawing Scale:3/16"=1.0' GREENLOGOV ` ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#B: Total System Size:11.520kW Array Size:5.040kW 1 circuit of 7 on a 20A breaker 1 circuit of 7 on a 20A breaker Azimuth:170° Pitch:15° Monitoring System: N SunPower Panel/Array Specifications: Panel:SPR-X22-360-D-AC Racking:SunPower Invisimount Panel.61.39"X 41.18" Array:34'10 5/8"X 8'7 3/8" Surface:38'9"X 11'10" Magic#:Invisimount Legend: ® 14 SunPower 360W Panels ® SunPower Invisimount Rail • 28 Eco-Fasten Quik Feet 2x6"Douglas Fir Rafter 16"O.C. o Notes: Number of Roof Layers: 1 Height above Roof Surface,4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: \��ED ARO �J' 0 .33 Q� y 16 �O F OF NE`N Drawn By:MA Drawing#4 of 11 Date:1/15/2019 REV:A Drawing Scale:3/16"=1.0' ,�GREENLOMCO ENERGY GreenLogia,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#B: Total System Size:11.520kW Array Size:5.040k1N 1 circuit of 7 on a 20A breaker 1 circuit of 7 on a 20A breaker Azimuth:170° Pitch:15° Monitoring System: N SunPower Panel/Array Specifications: Panel:SPR-X22-360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:34'10 5/8"X 8'7 3/8" Surface:38'9"X 11'10" Magic#:Invisimount Legend: ® 14 SunPower 360W Panels ® SunPower Invisimount Rail IT • 28 Eco-Fasten Quik Feet 2x6"Douglas Fir Rafter 16"O.C. o Notes: Number of Roof Layers.1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: J. S AZ '}C L`+,O 0 16 33 y0� Drawn By'. g#5 of 11 Date:1/15/2019 REV:A Drawing Scale:3/16"=1.0' GREENLOMECO ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#B: Total System Size:11.520kW Array Size:5.040kW 1 circuit of 7 on a 20A breaker 1 circuit of 7 on a 20A breaker Azimuth:170° Pitch:15° Monitoring System: it SunPower Panel/Array Specifications: Panel:SPR-X22-360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:34'10 5/8"X 8'7 3/8" 2 3 Surface:38'9"X 11'10" Magic*Invisimount Legend: ® 14 SunPower 360W Panels ® SunPower Invisimount Rail 2 3 ® 28 Eco-Fasten Quik Feet NyNy 8 2x6"Douglas Fir Rafter 16"O.C. o Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System'3.5psf EngineedArchitect Seal: 63'5 -ko O F NO Drawn By:MA Drawing#6 of 11 Date:1/15/2019 REV:A Drawing Scale:3/16"=1.0' GREENLOGM® ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#C: Total System Size:11.520kW Array Size 2.880kW 1 circuit of 8 on a 20A breaker Azimuth:170° Pitch:23° Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X22-360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'7 3/4"X 6'11 1/8" Surface:23'4"X 8'10" x-1----3 x X_ Magic#:Invisimount Legend: ® 8 SunPower 360W Panels ® SunPower Invisimount Rail • 20 Eco-Fasten Quik Feet Q 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seill: ` CESJl �q ` 63 y0� Drawn A-_ ing#7 of 11 Date:1/15/2019 REV:A Drawing Scale:1/4"=1.0' LOOV ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#C: Total System Size:11.520kW Array Size:2.880kW 1 circuit of 8 on a 20A breaker Azimuth:170° Pitch:23° Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X22-360-D-AC Racking:SunPower Invisimount - Panel:61.39"X 41.18" Array:20'7 3/4"X 6'11 1/8" Surface:23'4"X 8'10" Magic#:Invisimount Legend: ® 8 SunPower 360W Panels ® SunPower Invisimount Rail • 20 Eco-Fasten Quik Feet 8 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used-Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal D ARC J S C% NO. Drawn By:M - a g#8 of 11 Date:1/15/2019 1 REV:A Drawing Scale:1/4"=1.0' ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#C: Total System Size:11.520kW Array Size:2.880kW 1 circuit of 8 on a 20A breaker Azimuth:170° Pitch:23" Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X22-360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'7 3/4"X 6'11 1/8" Surface:23'4"X 8'10" Magic#:Invisimount Legend: d ® 8 SunPower 360W Panels ® SunPower Invisimount Rail • 20 Eco-Fasten Quik Feet 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: ARO 441 �� { 0 02 iF F NES Draw y:MA Drawing#9 of 11 Date:1/15/2019 REV:A Drawing Scale:1/4"=1.0' No Vent ®ipes Will -Be Covered By The Solar Arra � GREENLOMC LEGEND: ENERGY AR -Access roof per R202 definitions RAP -Roof access point-to be away from RWV -Roof with valley. GreenLogia,LLC Approved overheadobstructions,doors, 18"minimum from valley windows,decks,fences,landscaping Nardolillo,Lou GA -Ground access area per R324 7.3 width AP -Access Pathway,36"minimum SVO -Smoke vent operation per 3850 Camp Mineola Road to be same as AP as measured at eave width per R324.74 and R324.7 5 R324 7.7.18"minimum from ridge Mattituck,NY 11952 Total System Size:11.520kW 1 circuit of 10 on a 20A breaker 1 circuit of 7 on a 20A breaker 1 circuit of 7 on a 20A breaker RAP 1 circuit of 8 on a 20A breaker GA �4P GA Azimuth:170' GA Monitoring System: SunPower Panel/Array Specifications: API Panel.SPR-X22-360-D-AC I Racking:SunPower Invisimount I SVO I I Panel:61.39"X 41.18" I i Array:59'1"X 34'4" I I Surface:62'1"X 52'8" I I Magic#:Invisimount API AP Legend: I 1 ® 32 SunPower 360W Panels I I I I SunPower Invisimount Rad _ I 1 _ • 80 Eco-Fasten Quik Feet SVO 8 2x8"Douglas Fir Rafter 16"O.C. 8 SunPower SVO _ __ SVO _ 2x6"Douglas Fir Rafter 16"O.C. 360W Panels Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof toad of PV System:3.5psf Engineer/Architect Seal: ����ED ARC �C 10 SunPower 360W Panels " �}� ; -A 14 SunPower \ 0x1 s, 3 36QW Panels Meter • Drawn By:MA Drawing#10 of 11 Date:1/15/2019 REV:A Drawing Scale:3/32"=1.0' -- — NEW ECJIPMENT — — — FXISTING SERVICE 120/2-40, 1PH, .51V PV—SA-1 `A7 200A ; 1rff V T- 1 1 V0 AC—COMBINER PANEL PV—SA-2 AC—CMD-1 s � i AC DISCONNECT r'� (-V LQN)S ONLY} AC—USC-1 F � - N • 1 6 E1 B ( 1 I { ' ( BAR, i I PV—SA-3 }---�MAIN EJ ® . . . jFUSED A 8 N EGC EGC EGO EXISTING AC PANEL (EXISTING #6 � II GEC li�RG',€ERS'QLE v€'LIGE --" Cu PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Nardolillo, Lou 3850 Camp Mineola Road ENERGY Mattituck, NY 11952 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Nardolillo-3LD1 Revision: 1 Revised: 12/5/18 EQUIPMENT& COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-X22-360-C-AC, 1-CIRCUIT OF 10-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-X22-360-C-AC, 1-CIRCUIT OF 10-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUN POWER SPR-X22-360-C-AC, 1-CIRCUIT OF 12-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER,MAX VOLTAGE MAX. AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 3600 WATTS 211-264 VAC 14.64 A AC 240 V,AC PV-SA-2 3600 WATTS 211-264 VAC 14.64 A AC 240 V,AC PV-SA-3 4320 WATTS 211-264 VAC 17.56 A AC 240 V,AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Nardolillo, Lou 3850 Camp Mineola Road ENERGY Mattituck, NY 11952 ELIMINATING THE COST OF,ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION P�Je 2 of 3 Drawing No: Nardolillo-KD1 Revision: 1 Revised: 12/5/18 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMB-1 AC COMBINER PANEL 250V, 100A, NEMA-1, 1-PH, 3-WIRE BKR-1 CIRCUIT BREAKER, PV-SA-1 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-2 CIRCUIT BREAKER, PV-SA-2 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A BKR-3 CIRCUIT BREAKER, PV-SA-3 MATCH AC COMBINER PANEL BRAND, 2-POLE, 20A AC-DSC-1 AC DISCONNECT SWITCH (LINE TAP) 250V, 60A, NEMA-1, FUSED; FUSE RATING: SO CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4" PVC-40 12 / 6 B THWN-2 1-1/2" PVC-40 4 / 4 C THWN-2 1-1/2" EMT 4 / 4 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE, DISTANCE,AND DERATING FACTORS. 2.) ELECTRICAL CONDUIT TO BE MIN. PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIREMENTS. 4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER MINIMUM. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Nardolillo, Lou `''t, "" � l I 3850 Camp Mineola Road = E F\' ; t>� Mattituck, NV 11952 ELIMINATING THE COST O ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Nardolillo-KD1 Revision: 1 Revised: 12/5/18 __j >�'?�%>�:`,�.;r;��:'t, ��.;ate'',,.--"'` � . Y; •u' a; Design`Driven Advantages module aesthetics ano e"fictency' Unmatched module reliability-' SERIES No e ectroly`tic cacacitnrs 25 yee,Combined Power and ` ,cduct Warrar`;y Cat'fornia RL_le TI =hale 1 co-npliant Maximize Value for Roof Size sys;ern for roof,not s-mrg,mer:e•- optlmi7e performance of earn mocuie Expand Deployment Options complex roofsand p itt.ld!snaoing Small;;js ems Optimize System and Installation Efficiency System expendao ty SjnPower',AC mo.ules,whlcn nclude a factory-Integrated SunDoojer Simplify& Speed II1Staiiatlort mtcrclnver.er,prov ice a revolutionary combination of high efficiency,high Factory-integrated mice oinver cer re,rabllity :rd module-level DC-to-AC power ccrversion Designed Rob,,,st,doubl£,­?ck,r� AC connectors Design`!ex bi!�ty rspecifically`or use with Sur�Po,,ver Invisi Mount"I and the SunPovver • ,rfsl�e arid onsl�e No DC std'ng sizing process Mcr tonng System,SunPovrer AC modules enable rapid ristallation,best- Fevve,ir�-ta dtlon steps th:;r competing in-class system aesthetic.and Into:tlVe VISIbIIIIy into system pe•-formanre systems Intuit,e comrinission.ng A I:his comes with the best Co—o-fined Power and Product warranty'n ti-e Indusiry Component of Complete System • F3U'� `!;°r Use with S;1nl'ob'+'er"I'lvisi!Vlt;l,'ttr'" and the sunPower Mor for fig System;PVSSxa Grid Support Utility-Interactive Smart Inverter Slap£r:3r sfst£:rn rr>Ilability ;nd aes heti:s S,1nPower's new Type D AC module is UL rested and certified to UL 1741 SA and provides advanced smar<Inverter ft.nctrons Stn ower iy !�AC modules are fully comp�lant Wid- the California Rule 221 Phase reCUlref7le r'ts,and the Ride 21 grid p i ofile s eas,•y set cluring _:i comrnis�lo llrg rtn S,:•1PoWer_'VS`x rnoruror i rig nar:hr,are M sunpower.com 7 IEEE 15-13-20143 CA Ri-ke 213 SRD Prcf I-= (dcfau I:settings) m,n /nor- /rTIaX ---rn,n /-,,.ori max 595 60-0 G0,5 585/600/605 ,Power Facto' 09 'I/l 00 0 8�)lead CO/0 85!a ......... ...... 9 .zl 69 Vai- R ea c,I v a Power Vol! 'VAr Volta @2AO v -,l 1 2 ')40 264 V pe 2 V 83 21, I 21, 8V @2A0 V 1 33 A I Max Current 0%208 V 154 A-- -- ------- D(-4A('C,:C Cc,ivei sion Effic-no,, C2110 V 96 0% C2-11 0 V 12(single phase) I Max Units Per 20 A 3,anch Ci,cii-, 00208 v 10(,WC PCIe) le)v Power 320 W.320 VA Nic aclive phase balacc ng For 3 plasz ins,allat ion!,_____ V W91, Aulil SPR X22.360-D-AC l 25-year lin uted povel %Awdi I ar cy 1 Watiannes Nomina:Fciwei'(Pnomi) 360W 2S-.veai limited PIO&Ct warrenty Power Tolerance UL'i-sted to UL 1741 SA A\�u Pane Ffticencv` 22 24b SRDs IEEE 15A7-2003,KHE 1547a-20,4,CA lerylp Coef (power) 0 2q4%/'C Uc,21 Phase • Three bypass diodes • OV Rapid Shutdown Equipmerit SI-aae Tolerance -Irtegrazec module-evel maxima'-1 ciower poin, Equipment Grog ndii-go �21­6�03,UL 9-103 Connectcrs and cab es (lead break-1 sconnoction.) g, Lv I\v'o d,I I, Mv, jp UL 1 11,11 A, �(T-.,, e - fireiating) Operating 7-rip -401 to-1,RS'F(-z'0°C Lo -85' Certificatiors Enables insta"at c,i in a.-cci dance with Max Ambien:Temp 122'F(50'Q NEC 690 6 - ------------ - - ----- Wiric. 6,p.t,.',300t)Pa,2.05kg/rr,-'f:.)tit&bac/ NEC 690 12 Paoid Shi­.rco,.,,.,n(i-side and MaA Load Snow '25psf,6000 Pa,611 !<ghertz---------frcini: ouzsidle the a,raj' Impact Resistance 'I inch(25 rn,n)diameter hail:)t 52 rnph(223 mis) iNEC 690 15 AC Connectors,690 33(A)-(E)(1) FCC and ICES-003 Class B v Aw When used Iriv ,Mourt ack ng(UL 2703). 1 Solar Cells 96 Vor,coysialline',laxeon Ge,, -regrat-cc,-our.cJiiigai-cibcrding I H-gh*ra-sm sFion­npered a;ss vv to arl. Cass,4,ire I aeo Fro,it Glass 'lective ------- —-- - - e, oating plr)le5[ Pniem,;), c(,gradation Go Environinenla Rating, Outdoor i-a,.,d Frame Class' olacK ancid zed(Ngnesz AAVA I ming) 280 mm '111 02 In Weigh', 45 5 lbs'20 6 kg) A Recornfr"pric'ed Mak 1 3 in (33 rT!rf)) Moduie Soacmg EE 1107 mm E [43 6 in] 1046 mm W= 11-pest of aver 3,200 s,licor sclar v?nels,Photor'Oodt,le Sui,,,e,,,Feo 2014 A [412 In] J '#1 rant,ri'Pv vodule Dutatil ty Inil.ative Pu tmc R,,I)oq Fr-mijrl-ofei CSE.Feb 201 v2 out J thetopeight—irgest mrU{aCLL rei,-,were LPSCG C..rnpoa,j,,' et a "AmPowe,Nlod.jl-, 30 mm v ti 21n] Degradation Rate"Sur.Powerwl-re ozper Feb 20','-See k%w su powL,cci-ni'tacis fv deta is -=acwy set co'547a-2014 defaUt settings CA Rule 2'de cult settings prof le se,cluing "Starcard-,est Cordi-,tons il Jljjl.,IIM2 vac ante,AM 251 Cl \IRN callba:o-1 standard [61.3 in) @U.L NTRAC11YE commss or,rg See the,�qUIIICX I-StG/1'atl0f,G.,,,4�#518101 fo,mare informalicil 1558 mm SOMS currprc,LNCS FFind—ia,p A 19t vot3ge is fun v contairodmm r[m,rn)klul,l LISTED -3ascdl on evpraee o'rneasved power,alucs cvinq Pi oducti,q Please read the safe*y and Instal a*i.-i instructiogs for derails Module Fire Performance Type 2 See surpom,com.'facts fo,rnoi L refererce,nci rnar,:rl For mere dela Is see extencec datasheet www sunrowe-cc-,-'r a,-nsl tecLs 5 18 9 S;:,Re,8 r 33GREENLOGOC® ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#A: Total System Size.11.520kkAJ Array Size:3.600kW 1 circuit of 10 on a 20A breaker Azimuth: 170° Pitch:22* Monitoring System. N SunPower Panel/Array Specifications: —�� Panel:SPR X22-360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:30'10"X 10'5" Surface:33'3"X 14'3" Magic#:Invisimount Legend: ® 10 SunPower 360W Panels ® SunPower Invisimount Rail ® 20 Eco-Fasten Quik Feet I8 - 2x8"Dougias Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: Ac? CIQ Q -9j 0?163'' yOQ -- 4F N ENS yawn By:MA Drawing#1 of 11 Date:1/15/2019 REV.A Dra nvurgSc`ale:-3/16"=1.0' 0 GREENS IV ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#A: Total System Size: 11.520kW Array Size:3.600kW 1 circuit of 10 on a 20A breaker Azimuth:170° Pitch:22° Monitoring System: SunPower PaneUArray Specifications: I I Panel:SPR-X22-360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:30'10"X 10'5" Surface:33'3"X 14'3" Magic#:Invisimount Legend: ® 10 SunPower 360W Panels ® SunPower Invisimount Rail • 20 Eco-Fasten Quik Feet 8 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: y 021633 yOQ OP NES Drawn y:MA Drawing#2 of 11 o. .1/15/2019 REV:A Drawing Scale:3/16"=1.0' G!! EENT GIS® ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#A: Total System Size:11.520kW Array Size:3.600kW 1 circuit of 10 on a 20A breaker Azimuth:170° Pitch:22' Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X22-360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" 1 1 Array.30'10"X 10'5" Surface:33'3"X 14'3" Magic#:Invisimount Legend: ® 10 SunPower 360W Panels ® SunPower Invisimount Rail 1 1 S 20 Eco-Faster Qulk Feet 6 2x8'Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: �N �S ] ST C 1510 �- -9 X21633 yOQ' OF IVE'� Dra y:MA Drawing#3 of 11 1/15/2019 1 REV:A Drawing Scale-3/16"=1.0' �GREENLGMC ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#B: Total System Size. 11.520kW Array Size:5.040kW 1 circuit of 7 on a 20A breaker 1 circuit of 7 on a 20A breaker Azimuth:170° Pitch:15' Monitoring System: N SunPower Panel/Array Specifications: Panel:SPR-X22-360-D-AC Racking:SunPower Invisimount Panel.61.39"X 41.18" Array:34'10 5/8"X 8'7 3/8" Surface:38'9"X 11'10" Magic#:Invisimount Legend: ® 14 SunPower 360W Panels ® SunPower Invisimount Rail XX x x X . x x ® 28 Eco-Fasten Quik Feet H 2x6"Douglas Fir Rafter 16"O.C. o Notes- Number of Roof Layers:1 Height above Roof Surface:4" Materials Used.Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: ,`�R A q �0� — 1 ST C ,9 0216 35 yOQ Dra By:MA Drawing#4 of 11 ,Datdr-1/15/2019 REV:A Drawing Scale 3/16"=1.0' GREENLOGOC" ENERGY GreenLogic,LLC Approved Nardoldlo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#B: "total System Size: 11.520kW Array Size:5.040kW ---------- --- 1 circuit of 7 on a 20A breaker 1 circuit of 7 on a 20A breaker Azimuth:170° Pitch:15' Monitoring System: N SunPower PaneVArray Specifications: U Panel:SPR-X22-360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:34'10 5/8"X 8'7 3/8" Surface:38'9"X 11'10" Magic#:Invisimount Legend: ® 14 SunPower 360W Panels ® SunPower Invisimount Rail ® 28 Eco-Fasten Quik Feet \ II 8 H 2x6"Douglas Fir Rafter 16"O.C. o Notes: Number of Roof Layers:1 Height above Roof Surface'4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: P ® AH s�S ] ST q 021633 AQP OF NES Drawg/ y:MA Drawing#5 of 11 m'e 1/15/2019 REV:A Drawing Scale:3/16"=1.0' GREENL ormico ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#B: Total System Size: 11.520kW Array Size:5.04OkW 1 circuit of 7 on a 20A breaker 1 circuit of 7 on a 20A breaker Azimuth:170° Pitch:15° Monitoring System: N SunPower Panef/Array Specfcations: Panel:SPR-X22-360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" 2 3 Array:34'10 5/8"X 8'7 3/8" Surface:38'9"X 11'10" Magic#:Invisimount Legend: ® 14 SunPower 360W Panels ® SunPower Invisimount Rail 2 3 ® 28 Eco-Fasten Quik Feet -77 --7= 8� 2x6"Douglas Fir Rafter 16"O.C. o Notes- Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: I �a AR , ST' C ,,0 .q 0216 3*3 ypQ' OF NES Drawn y:MA I Drawing#6 of 11 ata /15/2019 1 REV:A Drawing Scale:3/16"=1.0' GREENLOGWO ENERGY GreenLogia,LLC Approved Nardoldlo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#C• Total System Size: 11.520kW Array Size:2.880kW 1 circuit of 8 on a 20A breaker Azimuth. 170° Pitch:23° Monitoring System. N SunPower Panel/Array Specifications: Panel SPR X22-360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'7 314"X 6'11 1/8" Surface:23'4"X 8'10" x x Magic#:Invisimount Legend: ® 8 SunPower 360W Panels ® SunPower Invisimount Rail 20 Eco-Fasten Quik Feet x x x x 8 B 2x8"Douglas Fir Rafter 16"D.C. 57 77 Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: AR -y 021635 y0� OF NES Drawn :MA Drawing#7 of 11 /15/2019 REV:A Drawing Scale: 1/4"=1.0' GREENLOGOCO ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#C: Total System Size.11.520kW Array Size*2.880kW 1 circuit of 8 on a 20A breaker Azimuth:170° Pitch:23° Monitoring System: SunPower 1) Panel/Array Specifications: Panel-SPR-X22-360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'7 3/4"X 6'11 1/8" Surface:23'4"X 8'10" Magic#:Invisimount Legend: ® 8 SunPower 360W Panels ® SunPower Invisimount Rail ® 20 Eco-Fasten Quik Feet 8 2x8"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:I Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: R ® AR �_`l�t�5 J ST -9j 021633 yob QF NES Draw By:MA Drawing#8 of 11 e:1/15/2019 REV:A Drawing Scale- 1/4"=1.0' GREENLOGMe ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 Surface#C: Total System Size:11.520kW Array Size:2.880kW 1 circuit of 8 on a 20A breaker Azimuth: 170° Pitch:23° Monitoring System: N SunPower Panel/Array Specifications: Panel:SPR X22-360-D-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'7 3/4"X 6'11 1/8" Surface:23'4"X 8'10" Magic#.Invisimount Legend: ® 8 SunPower 360W Panels ® SunPower Invisimount Rail • 20 Eco-Fasten Quik Feet 8 B 2x8"Douglas Fir Rafter 16"O.C. Notes- Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: EV' AR C L %o 9 21635 y0� OF NE`S'S Drawn y:MA Drawing#9 of 11 t : /15/2019 REV:A Drawing Scale: 1/4"=1.0' No tient Pipes Will Be Covered By The Solar Arrau I �xjGREENLOGOC° LEGEND. ENERGY AR -Access roof per R202 definitions RAP -Roof access point-to be away from RWV -Roofwfth valley, GreenLogic,LLC Approved overhead obstructions,doors, 18"minimum from valley Nardolilio,LOU wmdows,decks,fences,landscaping GA -Ground access area per R324.7.3 width AP -Access Pathway,36"minimum SVO -Smoke vent operation per 3850 Camp Mineola Road to be same as AP as measured at eave %vidth per R324 7 4 and R324.7.5 R324 7.7,18"minimum from ridge Mattituck,NY 11952 Total System Size:11.520kW 1 circuit of 10 on a 20A breaker 1 circuit of 7 on a 20A breaker 1 circuit of 7 on a 20A breaker RAP 1 circuit of 8 on a 20A breaker GA RAP FGA Azimuth:170° GAf Monitoring System: SunPower 1 Panel/Array Specifications: AP i Panel-SPR-X22-360-D-AC I Racking:SunPower Invisimount L—__.-_.-.—.---_--- — 1 I Panel:61.39"X41.18" SVO 1 i Array:59'1"X 34'4" 1 1 Surface:62'1"X 52'8" 1 I Magic#:Invisimount AP 1 lAP Legend: 1 t ® 32 SunPower 360W Panels I i I I SunPower Invisimount Rail 68 Eco-Fasten Quik Feet SVO 8 B 2x8"Douglas Fir Rafter 16"O.C. 8 SunPower/ _____ SVO______ ____SVO ___ __ p 8 24"Douglas Fir Rafter 16"O.C. 360W Panels Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: / AR y 10 SunPower �T. 360W Panels 44KIX 7—'W—W--\j/ \17 7X7174 14 SunPower -g 021633 36OW Panels OP NE`N y Meter Drawn y:MA Drawing#10 of 11 Qat- 1/15/2019 REV:A Drawing Scale:3/32"=1.0' EES ENERGY GreenLogic,LLC Approved Nardolillo,Lou 3850 Camp Mineola Road Mattituck,NY 11952 - -- - - - ---_ - - --i- - ---- -- --------- --- - - - - -- - - -; ---- - --,----— }_._ Total System Size:11.520kW ¢ f i R(mww w ; I i 1 circuit of 10 on a 20A breaker 1 circuit of 7 on a 20A breaker 1 circuit of 7 on a 20A breaker 1 circuit of 8 on a 20A breaker - ----------- -J - `'-' ' Azimuth:170° i ECD-a Qid(Font-Sqm h wLmElock I EB { ( _-_ I j ! --- --f - EoDFa�3�ClidcFaotpa�irg f - ----.Y-_ _ ._f ------ -�---.- _`- Monitoring System: -_--_.- _ _.-.-- _ ----,----__--.-- -____-_ _____. _- .__ .- _ --___. ._ _-__- + j` i- i SunPower #1473+c45 CPI Gxn®lo'�aew 136 l i•--------, Panel/Array Specifications: Panel:SPR-X22-360-D-AC Racking:SunPower Invisimount - - I ;--- ----__-- -- -- _ •-_-.--- -_-.--- _ -_ _-� _ _ .l ;.-- --- __- __. __.._- -- �- - --- - _ _ ..._ _ _{_-__ _ - -------._------_.- - -.----- Panel:61.39"X4L18" -- --- -_ _ -- ------------l---- _ -i i 1 i I ' 1 Array:59'1"X34'4" ---------- 3 ! ! Surface:62'1'X 52'8' ..-__. _.___ __.___.__w_.._.___. .___.-.___._ .. _...._ _. . __. _ . .._.._ i f ��--- ,- •- , � •l� ��, - --�- � - Magic#:Invisimount ---- - ---------------------- ----- �-- ---- -_____,_—____,------ —_-_------- -�------s---- -------- Legend: Legend: ---------- _ --------- 32 SunPower 360W Panels SunPower Invisimount Rail ! • 68 Eco-Fasten Quik Feet j._.._ _. __..__. __•_--_--_-.-. __ _ __._._.___ _______ __ ------ __ ___ i __._ ____ --___{.__ __ `_ ____ _._ 0 2 2x8"Douglas Fir Rafter 16"O.C. ! 06 2x6"Douglas Fir Rafter l6"O.C.� __ Notes Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: �R AR A -q, 021633 CoQ. OF NE`s IBy:MA7 Drawing#11 of 11 1/15/2019 REV:A Drawing Scale:3/32"=1.0'