Loading...
HomeMy WebLinkAbout42865-Z �uFFac K�dG Town of Southold 5/10/2019 z� P.O.Box 1179 o - 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 40375 Date: 5/10/2019 THIS CERTIFIES that the building IN GROUND POOL Location of Property: 55480 CR 48, Greenport SCTM#: 473889 Sec/Block/Lot: 44.-3-1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 7/10/2018 pursuant to which Building Permit No. 42865 dated 7/17/2018 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY IN-GROUND SWIMMING POOL, FENCED TO CODE, AS APPLIED FOR The certificate is issued to Andreadis,Katherine&Nikolas&or of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 42865 10-03-2018 PLUMBERS CERTIFICATION DATED N C\ n 0riz ignature Fall( TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o . SOUTHOLD, NY y�vl � �apR BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42865 Date: 7/17/2018 Permission is hereby granted to: Andreadis, Katherine & Nikolas 15-01 145th PI Whitestone, NY 11357 To: construct accessoryinround swimming-g g pool as applied for. At premises located at: 55480 CR 48, Greenport SCTM # 473889 Sec/Block/Lot# 44.-3-1 Pursuant to application dated 7/10/2018 and approved by the Building Inspector. To expire on 1/16/2020. Fees: SWIMMING POOLS -IN-GROUND WITH FENCE ENCLOSURE $250.00 CO - SWIMMING POOL $50.00 Total: $300.00 Bu in ector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00,Commercial$15.00 Date. 4q S New Construction: Q Old or Pre-existing Building: (check one) ,�` Location of Property: y U� C-0�1b A (49 S a��© l` House No. Street Hamlet Owner or Owners of Property:. Suffolk County Tax Map No 1000, Section Li 4 Block Lot I Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted:$ Applicant S nature pF SO(/��,®�o Town Hall Annex 411 Telephone(631)765-1802 54375 Main Road N Fax(631)765-9502 P.O.Box 1179 G Q Southold,NY 11971-0959 .�® • �o roper.riche rKa_town.south old.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Andreadis Address- 55480 CR 48 City: Greenport St: New York Zip: 11944 Budding Permit* 42865 Section: 44 Block: 3 Lot: 1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: BJ Electric License No: 2670-ME SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool X New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt 2 Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps 2 Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks 2 Disconnect Switches 2 Twist Lock Exit Fixtures TVSS Other Equipment: In ground swimming pool to include, bonding, control panel, 2-GFCI circuit breaker salt generator, 1-pool filter pump, 1-pool cleaner pump,2-pool lights Notes, Inspector Signature: Date: October 3 2018 81-Cert Electrical Compliance Form.xls a SOUTyO� # TOWN OF SOUTHOLD BUILDING DEPT. comm, 765-1602 INSPECTION " [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: rp A(0 L DATE l �' INSPECTOR -1 ho�aOF SOUTy�� # TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] IKSULATION [ ] FRAMING /STRAPPING [ 'FINAL Qa�� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ CODE VIOLATION [ ] CAULKING REMARKS: Svf A� Y rl� �" 0&6AJO�, '_.F � mak- � r � - DATE INSPECTOR a0F SOUjy # # TOWN OF SOUTHOLD BUILDING DEPT. cou765-1602 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] SULATION [ ] FRAMING /STRAPPING [ FINAL b- [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: 414r DATE 0***"/31 INSPECTOR r HM ENGINESUNG P.C. 3 CHERRYWOOD DRIVE EAST NORTHPORT,NY 11731 TEL:516-476-5392 EMAIL:HMARNIKA@OPTONLINE.NET June 27, 2018 Town of Southold Building Department Town Hall Southold,NY 11971 Dear Sir/Madam: This is to certify that the drainage facilities to be used exclusively for the construction of a swimming pool on the premises of: Andreadis Residence 55480 County Road 48 Southold,N.Y. 11971 will not require draining because the pool is constructed with a vinyl liner. The pool water will be continuously recirculated through the filter and will be reused from year to year. The drainage from the filter backwash is nominal and will not interfere with the public water supply, the existing sanitary facilities or public highways. Sincerely, HM E ineering P.C. T Hrvoj arnika P.E. FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(IST) _ t��y -------------------------------------- 'FOUNDATION (2ND) �y Ul ROUGH FRAMING& PLUMBING y INSULATION PER N.Y. y STATE ENERGY CODE . r vw WdKwt �. FINAL ADDITIONAL COMMENTS -/ — 5 C-1 / 1®°3�I c,P - ;Z r\ p 0 ` d H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 / Survey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined ,20 Single&Separate Truss Identification Form Storm-Water Assessment Form Contact: LT- Q&- Approved ,201 Mail to: Disapproved a/c Phone: Expiration '20 D L5 l5DIVIE '�) Bit 'n ector JUL 1 0 201 APPLICATION FOR BUILDING PERMIT Datc 20 BUILDING DEPT. INSTRUCTIONS TOWN O:f S0UTHOLD a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificaie of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has'not been completed within 18-months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or -Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Sfgnature of applicant or name, if acorpor/ation)q boo A10-Ni t 'd 5D'A-k1( / (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder ��✓l�fu � �v)��tC,f°� Name of owner of premises (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name'ancl titl`e,of;corporat6 officer) Builders Licenseo. Plumbers License'No:' Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: c SS Wjg\-�A !.1� q� House Number, StreetJ Hamlet County Tax Map No. 1000 Section 44 A4 Block 3 Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy Suv�yvl .�y cad Cyiti�g d ) 2 o x `1 q 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work iN o0 (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of 8. Dimensions of entire new construction: Front Rear Depth .df Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises 5fitA NA&ta A,!> Address S��`�� ��S Ph1 ne No. }� 3 F6 Name of Architect Address Phone No Name of Contractor Addresssoxw mom X1,1 Phone No. 0Z- 6 Yo-S_3- 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO_ * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO x * IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF L being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract)above named, CONNIE D.BUNCH (S)He is the Notary Pub is, State of New Verk — (Contractor, Agent, Corporate Officer, etc.) No.01 BU6185060 Qualified in Suffolk County of said owner or owners, and is duly authorized to perform or have performed the saidCOv l aRg'Afe-3 ?ppIication; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of 204_ Notary Public Signa ure o Applicant Scott A_ Russell ��°SAY � �T O)RIM[W-A. ]E)R, SUPERVISOR �� IMC,A\N A�GrIE��UEN�C' SOUTHOLD TOWN HALL-P_O.Box 1179 0 Ca z 53095 Main Road-SOUTHOLD NEW YORK 11971 �syo �- Town of iSo u th o l d CHA PTER 236 - STORMWATER MANAGEMENT WORK SHEET (TO BE COMPLETED BY THE APPLICANT) l�OWING: .---.� ------ Yes No (CHECK ALL THAT APPLY ❑ffA. Clearing, grubbing, grading or stripping of Iand which affects more _ ®� than 5,000 square feet of ground surface. ] B. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area ❑d C. Site preparation on slopes which exceed 10 feet vertical rise to FW100 feet of horizontal distance- 4D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area- L1 rea_L 1 . Site preparation within the one-hundred-year floodplain as depicted on-.FIRM Map of any watercourse.. f ® F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. F�and answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, ure, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project_ answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan ompleted Check list Form to the Building Departm uLui h-your Building Permit Application. APPL)CAN?_ (Property Owner,Design Professiona)-Agent,Contractor,Other) - S.0-T.M. 1000 Date. NAME moo,, - Cke- � District 41 � Section Block Lot IFOR BUILDING Di=PARTNIt\ O T 12SE INL` m / t� - -: Contact)nforaltorr �/ ( ry,�6� Reviewed By_�6 Prate. _ opei�ty Address / Location of Constiuction Work D k — — — — — — — — a — — — — — — — — Approved for processing Building Permit. J Stormwater Management Control Plan Not Req utred. ��.kJ��� `� �� 4--�f -k — �E Storm.vaier Manageim ,t Ccnt;ol P: .,�Rcq, -d— t (Forward io Engineering Department for Re,,.e:v) FORM SMCP - TOS MAY 201 n SOUT,�, 1� Telephone(631)765-1809, row Ra Amex 20 G ro er.richert {how nlsoutho�d.n .us 5437 Road„C — 2 P_U. 179 v Southold,NY 11971-0959 Ol�COUN TOVI BUILDING DEYAR rMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Date: Company Name: , Name: License No.: Address: l� Phone No.: �/� ��� D(O�a P `300III JOBSITE INFORMATION: (*Indicates required information) *Name: *Address: 0 -T *Cross Street: 0 *Phone No.: d �� Permit No.: 5 - Lot: Tax Map District: 1000 Section: Block: ?z____ *BRIEF DESCRIPTION OF WORK (Please Print Clearly) W1 MIni a t_1P� �S '4 tiv11101 L �zs Cr (Please Circle All That Apply) Fina *Is job ready for inspection: YES / O Rough In . *Do you need a Temp Certificate: YES NO Temp Information (If needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground N=13,er of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for inspection Form J Il �l SURVEY OF: TEST HOLE DATA PROPERTY LOCATED AT NEAR ARSHAMOMOGUE I RES W/ PUBLIC WATER BY: ROY K.(NOTORESSIG. SCALESEPTIC PE 8 TOWN OF SOUTHOLD APRIL B. 2017 x9:30 AM SUFFOLK COUNTY. NEW YORK vo r 0.0'-0.2' TOP SOIL PT Of 0.2'-3.0' BROWN SILTY SAND SM S.C.T.M. # 1880-44-3-1 fD� R LJ _ AREA = 112,500.0 SF. = 2.5826 ACRES ` f DF P1V EWATERG �c:R. DA a F o 3 SADARK BROWN ND a GRAVEL SCALE: 1"=60' ` S 76°O fM�T SERV CE 4 8� ^ a o 3.0'-8.0� SP NOTE: THE EXISTENCE OF RIGHT OF WAYS, ,3 3 2p»E ~ 8.0'-10.5' GRAVELLY SAPALE ND SP WETLANDS AND/OR EASEMENTS OF RECORD RES, ��.�0, WATER WATER IF ANY. NOT SHOWN ARE NOT GUARANTEED. � METER o WET BROWN ELEVATIONS REFER TO 1988 NAVD �o � , °i\ POLE 10.5'-17.0' — SAND a GRAVEL SP 14 M, e, ..MIN 0) 10' 8 DIA 20' 8' DIA 20' MIN. LAND N/F - Do ® TEST HOLE PIPING,SEPTIC TANK,PIPING{ L.P. GRADING ANNA 8 �O 14 EL 13.0 5 i CLEANOUT DETAIL { { IOANNIS TSIMIS FF. EL. RES W/ PUBLIC WATER e0E`l, 1N 15.501198'8o SEND PLUGR /-SUITABLE COVER _ _ 7.7• LOCKING CASTING SEPTIC ,62'2' 22.2 2 STY Y W �A?5 TO GRADE PROP. GROUND �►� EXISTING m 3 BEDROOMS 12 " _- w ADti3' w RES GRE ARE rn 1/4 �� AMA XISf 1' MIN�REA OF PROPOSED 16 Nn SAN ARY EL RfS, •_ E NG .- '- P1TCH S4' DIA 2 MAX F[LL ` y 15 N ' SEWER PIPE MIN. I� � -_. /meq r^ 45' 64 \365 4' DIA 1/B. C3 a 0 0 0 /D.e K85'�I�1G SA ITARY TO BE ELBONS Noll MIN. �3Vr� 6� o 0 0 0 A F O / ANOIONE REMOVED o 0 0 0 = \ O u 0 l(� O \ ' O y ELBOWS COLLAR m Z 00'� COL AR W b Y lu � 1 r . ¢w of S o. 3.5 N� �\ 2\ �� a< DACICFILL WITH = HIGHEST r\•� y HOUSE TRAP/CLEANOUT MUST BE INSTALLED ;= CLEAN SAND AND GROUND WATER EXPECT ;jai _`^pU \I GRAVEL MATERIAL EL 2.5 GRD. WATER 2 Q 7`- ON THIF INSTALLED AT E SEPTIC TANK INLET WASTELINE. < 1[1 IT MUST BE INSTALLED TO GRADE. ALL U �_,. ti UTILIES REOUIRE A 5 FT MINIMUM SANITARY SYSTEM DETAIL Z 2 C { U IL _jti 3 A� SEPERATION TO THE SEPTIC SYSTEM 3 21 �ti 3 z� � Q �+ e>•I-u0 mlQu ;oz 0 lu LOCKING CASTING ,1b J"'ti 2(A �m C/• Q �` Q V7 TO GRADE tip• �/ ti �7 FINISHED m 24' 1' MIN. 24' 6' MIN TOP U ° ^ (q GRADE' .� _ SLAB it 1'MIN. 2' MAX. ILl 1/4 PITCH � 14 /� , 20' 20' qh INLET CLASS MIN' W U) FROM SEPTIC TANK m 2'MAX. 2400 p0 iD _j m PIPE 1/B'PITCH 1/e OR EQUIVALENT z _ PITCH ti� o ` < 4'DIA MIN W CLAS&240e by O O D O O w ° i`m 5.0 m /age 4' OIA MIN ' DEPTH _. CLASS 2400 --_ 8 •- - E 3.0'MIN` _ PIP LAND N/F i ND COLLAR 8.0 DIA LEACHING POOL- ORe m a9 Eou1v�LENr PENKA L GIBINSKA o O s.o DIA RES W/ PUBLIC WATER 0 w ROSSOVER PIPES W SEPTIC TANK a SEPTIC 4 Z = BACKFILL WITH Z e = 8' DIA 1p CONIC. O\4 2 CLEAN SAND AND ion Z GRAVEL MATERIAL GROUND HATER MON. TYPICAL 1500 GALLON SEPTIC TANK .zo EXPECTED _j J TYPICAL SANITARY LEACHING POOL GROUNDWATER 0) IN.T.S.I HOUl E DEOTAIL :N PORCH ,300.76 '0131- lei SURVEYED BY: THIS "1e' H 2'S e p x'00' MON. .�� ` PAUL BARYLSKI LAND SURVEYING OF SECTION r ALTERATION THE NR YORK STA E DUC TION L is n vlaunw � m V PATCH 0 G U E N Y 11772 OF sernaN T2.G of THE NEW rax srnrE EDUCATION LAK m I2. S COPIES OF THIS SURVEY MAP NOT REARING THE LAND SURVEYORS INKED 9,g 2 STO CR GUARANTEES EMBOSSED�CERTIFICASHALL nasSINDIC�INDICATED HEREIDERED ON SHBE ALL R'LM RU N TRUE LY TO COPY. � �R'RES °' DSOU ry0 SANS Ni THE PERSON FOR WHOM THE SURVEY IS PREPARED.AHD ON HIS BEHALF TO � 0 VEN F PHONE 631-294-6985 THE TITLE LISTED NEON COMPANY.'GOVERNMENTAL °AGENCY AND LENDING N m 6 P PID OCT — 5 2417 VACAN OINC o: FAX 6 31-6 2 7-3,18 6 DtsTrninomsIn S CERTIFICATIONS OON�TRANSFERASE TO ANnrnaNu 1'3 m a rPv T �® P A U L B A R Y L S K I a Y A H 0 0.C O M 6 CE CERTIFIED ANTO. 050782 ,� DECEMBER 1, 2016 NIKOLKATHERINE ANDREADIS ' OS ANDREADIS HELEN ANDREADIS IRUMDINGDEPT. S� SAND S�¢ 4-10-2017: TOPO & PROP. SANITARY SYSTEM HELEN OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY TOWN OFSO=OLD 7-17-2017: REVISE SURVEY 2398-1 9-15-2017: LOCATED ADJOINING RES'S oa APPRO ED AS NOTED ,DATE: I.P.# oZ RETAIN STORM WATER RUNOFF FEE: ' 6,db BY: PURSUANT TO CHAPTER 236 'NOTIFY".BUILDING DEPARTMENT AT OF THE TOWN CODE. 765-1802, 8A TO 4 PM FOR THE FOLWWING INSPECTIONS: 11.-',FOUNDATION - TWO REQUIRED FOR POURED CONCRETE 2. ROUGH -FRAMING & PLUMBING 3. INSULATION 4. FINAL - CONSTRUCTION MUST ELECTRICAL BE COMPLETE FOR C.O. INSPECTION REQUIRED ALL CONSTRUCTION SHALL MEET,THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. ,NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. `ENOL-OSE POOL TO CODE, COMPLY WITH ALL CODES OF `.UPCN.COMPLETION NEW YORK STATE & TOWN CODES ! WORE"WATER'_ AS REQUIRED AND CONDITIONS OF n TnIFlAI Tae �,v`J i i iV LV I V-TTf9'CO>'T�i V ll L/ OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICATE OF OCCUPANCY TRACK FOR POOL NOTES: VINYL LINER 1.POOL AND PROPERTY TO CONFORM TO 2017 NYS UNIFORM CODE,THE 2015 IRC,2 nd PUMP PRINTING,AS AMENDED BY THE 2017 NYS UNIFORM CODE SUPPLEMENT,2017 FILTER SUPPLEMENT TO THE NYS ENERGY CONSERVATION CONSTRUCTION CODE,TOWN OF SKIMMER VINYL LINER SOUTHOLD CODE AND 2014 NATIONAL ELECTRIC CODE. (TYP. OF 3) 5" 3,500 PSI 2.POOL SHALL CONFORM TO ANSI/NSPI STANDARDS R326.3.1. RETURN FOAM PADDING 3.SECTION R326.7 POOL ALARM REQUIRED. (TYP. OF 5) ° CONCRETE 4.POOL SHALL COMPLY WITH BARRIER REQUIREMENTS SECTION R326.5. v 5.POOL SHALL COMPLY WITH INTERNATIONAL ENERGY CONSERVATION CODE SECTION 10" R403.10: POOLS AND PERMANENT SPA ENERGY CONSUMPTION(MANDATORY). ° SECTION R403.10.1 HEATERS a SECTION R403.10.2 TIME SWITCHES c SECTION R403.10.3 COVERS / I (4)REBAR a ° 48" 6.REBAR SHALL BE 3"MIN.CLEAR TO EARTH. �� PROPOSED VINYL 7.CONSTRUCTION METHODS AND PRECAUTIONS ARE DICTATED BY GROUND AND SOIL SWIMMING POOL CONDITIONS TO BE DETERMINED BY CONTRACTOR. ° ° a 8.LOCATION OF PROPOSED SWIMMING POOL AND POOL EQUIPMENT BY OTHERS AND 3' I I SHALL COMPLY WITH ALL LOCAL ZONING REQUIREMENTS. MIN.)l I DUAL MAIN DRAINS STEPS 20' v 9.ALL DRAIN COVERS TO MEET ALL REQUIREMENTS OF THE VIRGINIA GRAEME BAKER(VGB) WITH STRAINER (VGB POOL AND SPA SAFETY ACT. SAFETY ACT 10.SLOPE PATIO SURFACE 1/4" PER FOOT AWAY FROM POOL. �-- — APPROVED DRAINS) 11.BACKFILL MATERIAL TO BE FREE DRAINING GRANULAR MATERIAL(NO CLAY OR LARGE 5" ROCKS). \ I 12.SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ANSI/APSP-7. 13.NO SURCHARGE ALLOWED WITHIN 4'OF SHALLOW END AND 6'OF DEEP END. 14.NO DIVING EQUIPMENT PERMITTED. 44' TYPICAL WALL DETAIL 15.CONTRACTOR SHALL VERIFY SOIL BEARING LOADS PRIOR TO INSTALLATION OF POOL. 16. THIS PIAN IS FOR CONSTRUCTION ON PROPERTY AT 55480 COUNTY ROAD 48, SCALE: 3/4" = 1'-0" SOUTHOLD,N.Y.11971 ONLY. 17.REINFORCING STEEL SHALL BE INTERMEDIATE GRADE BILLET STEEL WITH A MINIMUM NOTE: POOL PLAN NOTES: LAP OF 30 BAR DIAMETERS. THIS IS A NON-DIVING POOL. NOT TO SCALE 1.WALLS SHALL BEAR ON UNDISTURBED SOIL 18.HM ENGINEERING,P.C.SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, 2.ALLCONCRETE SHALL BE PLACEDASA MONOLITHIC POUR. METHODS,TECHNIQUES OR PROCEDURES UTILIZED BY THE CONTRACTOR,NOR FOR THE SAFETY OF THE PUBLIC OR CONTRACTOR'S EMPLOYEES,OR FOR THE FAILURE OF THE CONTRACTOR TO CARRY OUT THE WORK IN ACCORDANCE WITH THIS PLAN. 8' 3.5' CONCRETE WALL _ _ _ (SEE SECTION 1 1/2- TO WASTE IF N 3 11�� � — THIS SHEET) 1 3 I_ HAIR & LINT STRAINER PUMP I—I' FILTER AUTO SKIMMER 4' 6' 14' 20' UNDISTURBED EARTH 3" COMPACTED SAND (TYP-) POOL BACK TO POOL POOL PROFILE NOT TO SCALE PREPARED FOR: DUAL MAIN ANDREADIS RESIDENCE SCHEMATIC PIPING ARRANGEMENT DRAINS 55480 COUNTY ROAD 48 NOT TO SCALE SOUTHOLD, N.Y. 11971 c d DATE: 06/27/2018 NOTE: n 2�� HM ENGINEERING, P.C. SCALE: AS SHOWN THESE PLANS ARE AN INSTRUMENT OF SERVICE AND ARE THE PROPERTY OF HM ENGINEERING P.C..UNAUTHORIZED (/ ` SHEET: 1 OF 1 ALTERATIONS OR ADDITIONS TO THESE DOCUMENTS ARE A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE 3 CHERRYWOOD DRIVE EAST NORTHPORT,NY 11731 EDUCATION LAW.INFRINGEMENTS WILL BE PROSECUTED. Tel:(516)476-5392 Fax-(631)980-7671 www.hmarnika@optonline.net RESIDENTIAL CONCRETE VOID WITHOUT RAISED SEAL AND BLUE SIGNATURE VINYL LINER POOL PLAN