Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
43595-Z
razz' Town of Southold 5/8/2019 o - P.O.Box 1179 ® 4� 53095 Main Rd mol 4:'0-0Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 40364 Date: 5/8/2019 THIS CERTIFIES that the building HOT TUB Location of Property: 2350 Clearview Ave., Southold SCTM#: 473889 Sec/Block/Lot: 70.-10-28.3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 3/28/2019 pursuant to which Building Permit No. 43595 dated 3/28/2019 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ACCESSORY HOT TUB PER ZBA DECISION#6690, DATED 10-17-2013, AS APPLIED FOR The certificate is issued to Southold LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 39188 12-31-2014 PLUMBERS CERTIFICATION DATED Au o ' e Signature r gUffQ�1 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERKS OFFICE o . SOUTHOLD NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 43595 Date: 3/28/2019 Permission is hereby granted to: Southold LLC 15439 Milan Way Naples , FL 34110 To: Install a Hot Tub upon an existing deck, ZBA decision #6690, as per State code barrier compliance. Replace BP# 39188 At premises located at: 2350 Clearview Ave., Southold SCTM #473889 Sec/Block/Lot# 70.-10-28.3 Pursuant to application dated 3/28/2019 and approved by the Building Inspector. To expire on 9/26/2020. Fees: PERMIT RENEWAL $125.00 Total: $125.00 Building Inspector �SUFEoi�,c TOWN OF SOUTHOLD BUILDING DEPARTMENT y a TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 39188 Date: 9/16/2014 Permission is hereby granted to: Southold LLC 15439 Milan Way Naples, FL 34110 To: install a Hot Tub upon an existing deck, ZBA decision #6690, as per State code barrier compliance At premises located at: 2350 Clearview Ave, Southold SCTM # 473889 Sec/Block/Lot# 70.-10-28.3 Pursuant to application dated 9/3/2014 and approved by the Building Inspector. To expire on 3/17/2016. Fees: SWIMMING POOLS -ABOVE-GROUND WITH REQUIRED FENCING $250.00 CO - SWIMMING POOL $50.00 Total: $300.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets,and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00, Commercial$15.00 Date. 1579 -3 New Construction: Old or Pre-existing Building: (check one) Location of Property: '23 50 C g V(6,&Z 0 �- House No. S eet amlet Owner or Owners of Property: Suffolk County Tax Map No 1000, Section -70 Block Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ App`l' ant 'g ture pF SOUP®l Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 ® a� roger.riche rt(aD-town.Southold.ny.us Southold,NY 11971-0959 �lyC®UNTj BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Southold LLC Address: 2350 Clearview Ave City: Southold St: NY Zip: 11971 Building Permit#. 39188 Section: 70 Block: 10 Lot: 28.3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: G&S Electric License No: 578-e SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub X Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect F1 Switches Twist Lock Exit Fixtures TVSS Other Equipment: supply 50a GFCI protected power to self contained hot tub Notes: Inspector Signature: Date: Dec 31 2014 81-Cert Electrical Compliance Form.xls I 1� l - �! �� �a0f SOUryo o l TOWN OF SOB DING-DEPT. 2 1,NSPPFE9 ION [ ] FOUNDATION 1 ST [ ] ROUGH PLUMBING [ ] FOUNDATION 2ND [ NSULATION [ ] FRAMING / STRAPPING [ ] FINAL ] [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: Ar 1--ced 96A4:rl s DATE /0 A3 ��� INSPECTOR SOF SOUIh, # # TOWN OF SOUTHOLD BUILDING DEPT. co 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] IN ATION [ ] FRAMING /STRAPPING [ FINAL #Ol 1 [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: i DATE INSPECTOR 'A �q► FIELD INSPECTION REPORT DATE COMMEMS CJS FOUNDATION(1ST) � - ...........---------........ - -- FOUNDATION(2ND) 81 ROUGH FRAAlING& � PLUIIMING ' to INSULATION PER N.Y. STATE ENERGY CbDE . 4 r FINAL fc, ) 8'5 7 #- �q (?? o tl;2 3. ® z Ia5• oc> reAU)CLO WAV Oz d TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 _`� Survey South oldTown.NorthFork.net PERMIT NO. 3°J� Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined ,20 D Storm-Water Assessment Form Contact: Approved 20 1 ��P ®3 2®�� Mail to: Disapproved a/c BLDG DEPT. ((,n� TOWN OF SOUTHOLD -Phone: Expiration �,20� Building Inspector APPLICATION FOR BUILDING PERMIT p Date ©O Z , 20 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.-Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or'ias�not•been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been-.enacted in the interim,the Building Inspector may authorize, in writing;the extension of the permit for an addition six months:Thereafter, a new permit shall be required. - APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings,additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. US ILE ��+, U N L�����''�',�, ) (Signature of applicant or name,if a corporation) E�JCLOSE I'06L,10 CODE � ' UPON Q0 -LETIORIt �`; h� "" breTP BEFORE„WATER _ ++yy¢¢ Iy� §g[ §�}� gy _ (Mailing address of applicant) �} 1- Cf 2 LJ'1 '8 51 4,, �I State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician, plumber or builder L ' P P # u j� Name of owner of premises /"' l!!C /r/0 - L O IFY BUILDING. DEPARTMENT AT (As @6 the tax roll-or late t*'PAWING INSPECTIONS- If applicant is a corporation, signature of duly authorized officer 1'. FOUNDATION-TWO REQUIRED FOR POURED C^v"ICRETIE (Name and title of corporate officer) 2 ROUGH-FRAMING,PLUMBING, STRAPPING, ELECTRICAL&CAULKING Builders License No. P �- .Q«,r,.� 3 INSULATION ���au. u ,�o�.� �. 4 FINAL-CONSTRUCTION &ELECTRICAL Plumbers License No. FAUST Bf-COMPLETE FOR C 0 Electricians License No. MEET THE Other Trade's License No. R' U ML,,i I: OF C:LiE; OF NEIN YOF=•F:-ATE N0T �E1QPONS1bLE FOR 1. Loc ion of land on which pro osed work will be done: DESIGN OR CONSTRUC ZION ERRORS L 3S6 GL�AZyl 4UC House Number Street Hamlet s County Tax Map No. 1000 Section 0 Block ® Lot Z o Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy R/*y 6 M b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work J-/VZ ;g�d CAJ4)4-- (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars C -13n 6. If business commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction. ront Rear Depth Height Num er of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 'e4 6 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO,-Will excess fill be removed from premises? YESn(—NO 14. Names of Owner of premises `L b O Address Phone No.51(, 6 Name of Architect Address Phone No ?Y / Name of Contractor lG Address Phone No. Z 5-3 D 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES_No * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS AY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey, 18. Are there any covenants and restrictions with respect to this property? * YES N04` * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OFJ�*!�-f�(J (� Z--being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing c ntract)above named, (S)He is the c l (Contractor,Agent,Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of 20 Notary Public S' natu of Applicant 1 BOARD MEMBERS �� Southold Town Hall ,Leslie Kanes Weisman,Chairperson OF $DUryO 53095 Main Road•P.O.Box 1179 Southold,NY 11971-0959 Eric Dantes Office Location: Gerard P.Goehringer G Q Town Annex/First Floor,Capital One Bank George Horning ;Q►O • �O 54375 Main Road(at Youngs Avenue) Ken Schneider COU Southold,Southold,NY 11971 http://southoldtown.noithfork.net RECEIVED ZONING BOARD OF APPEALS c , TOWN OF SOUTHOLD OCT 3 2013 Tel.(631)765-1809•Fax(631)765-9064 Q2� Q' ttthold Town Clerk FINDINGS,DELIBERATIONS AND DETERMINATION ZBA FILE: 6690 MEETING OF OCTOBER 17,2013 NAME OF APPLICANT: Michael Lloyd S.C.T.M.# 1000-70-10-28.3 PROPERTY LOCATION: 2350 Clearview Avenue, (corner Gagen's Landing Road) (adj. to Goose Creek) Southold,NY S_ FORA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without further steps under SEQRA, SUFFOLK COUNTY ADMINISTRATIVE CODE: This application was referred as required under the Suffolk County Administrative Code Sections A 14-14 to 23, and the Suffolk County Department of Planning issued its reply dated September 11, 2013 stating that this application is considered a matter for local determination as there appears to be no significant county-wide or inter-community impact. LWRP DETERMINATION: This application was referred for review under Chapter 268, Waterfront Consistency review of the Town of Southold Town Code and the Local Waterfront Revitalization Program (LWRP) Policy Standards. The LWRP Coordinator issued a recommendation dated September 23, 2013. Based upon the information provided on the LWRP Consistency Assessment Form submitted to this department, as well as the records available to us, it is our recommendation that the proposed action is EXEMPT from Coastal Consistency Review. PROPERTY FACTS/DESCRIPTION: Subject parcel is a non-conforming lot located in the R40 zone district. It is 35,019.80 square feet and is improved with a two story single family dwelling with attached garage, deck and screened porch. It has 132.77 feet of frontage on Clearview Avenue, 276.99 feet on Gagen's Landing Road, 137.48 feet on Goose Creek and 261.61 feet on the west property line as shown on the survey prepared by Kenneth M. Woychuk Land Surveying dated Sept. 21,2012, last revised 5-2-13. BASIS OF APPLICATION: Request for Variance from Article XXIII Section 280-124 and the building inspector's March 25, 2013, updated August 29, 2013 Notice of Disapproval based on an application for building permit for a deck with spa addition to existing single family dwelling, at; 1) less than the code required minimum front yard setback of 40 feet. RELIEF REQUESTED: The applicant requests a variance to construct a deck with spa addition with a front yard (Gagen's Landing Road)setback of 31.5 feet where the code requires a minimum front yard setback of 40 feet. Page 2 of 3 Octobcr 17,2013 ZBA#6690—Lloyd SCTM01000-70-10-28.3 ADDITIONAL INFORMATION: Although it's not on the survey, the site inspection as well as testimony showed that there is an existing hot tub in the location where the proposed deck will be built. FINDINGS OF FACT/REASONS FOR BOARD ACTION: The Zoning Board of Appeals held a public hearing on this application on October 3,2013 at which time written and oral evidence were presented. Based upon all testimony, documentation,personal inspection of the property and surrounding neighborhood, and other evidence,the Zoning Board finds the following facts to be true and relevant and makes the following findings: 1. Town Law 5267-b(3)(b)(11). Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. There is a large tree line bordering Gagen's Landing Road and no one will be able to see the new deck or hot tub from the street. The new structures will not block any neighbor's view or be near to any neighbor's property line. Furthermore, testimony was taken during the hearing that Gagen's Landing Road is not a very wide road and has limited use, in that its primary use is to access the beach and the boat ramp at the end of the road. 2. Town Law 5267-b(3)(b)(2). The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue,other than an area variance. The applicant's property has two front yards by code. One front yard is off Clearview Avenue,the second front yard border's Gagen's Landing Road. The applicant uses the yard bordering Clearview Avenue as his operational front yard. If the applicant applied to build a deck with hot tub on any other side of the property he would need a variance. 3. Town Law 5267-b(3)(b)(3) The variance granted herein is mathematically substantial, representing 21.0 % relief from the code. However, it is mitigated by the additional 30 feet from the edge of the property to the road pavement and the row of evergreen trees that block the view of the deck from the road. 4. Town Law 5267-b(3)(b)(4) No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. The proposed location offers the least potential adverse impact to Goose Creek. The applicant must comply with Chapter 236 of the Town's Storm Water Management Code. 5. Town Law 4267-b(3)(b)(5). The difficulty has been self-created. The applicant purchased the parcel after the Zoning Code was in effect and it is presumed that the applicant had actual or constructive knowledge of the limitations on the use of the parcel under the Zoning Code in effect prior to or at the time of purchase. 6. Town Law 5267-b. Grant the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a deck and hot tub while preserving and protecting the character of the neighborhood and the health,safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Dantes, seconded by Member Schneider, and duly carried,to GRANT, the variance as applied for and shown on the survey by Kenneth M. Woychuk L.L.S. dated Sept. 21, 2012, last revised May 2, 2013, and the building plan prepared by Mark Schwartz & Associates Architect dated September 6,2012. Any deviation from the survey, site plan and/or architectural drawings cited in this decision will result in delays and/or a possible denial by the Building Department of a building permit, and may require a new application and public hearing before the Zoning Board of Appeals. Page 3 of 3 October 17,2013 ZBA#6690—Lloyd SCPM#1000-70-10-28.3 Any deviation from the variance(s) granted herein as shown on the architectural drawings, site plan and/or survey cited above, such as alterations, extensions, or demolitions, are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. The Board reserves the right to substitute a similar design that is de minimis in nature for an alteration that does not increase the degree of nonconformity. Vote of the Board.- Ayes: Members Weisman (Chairperson), Schneider, Horning, Dantes. (Absent was: Member Goehringer) This Resolution was duly adopted(4-0). Leslie Kanes Weisman,Chairperson Approved for filing/t,� /,,r)/ /2013 Z Scott A. Russell �.��°Suck STO]KI��]MA\T]EIK SUPERVISORI�v1[A\�A\�G�]EI\� 1EN ]F SOUTHOLD TOWN HALL-P.O.Box 1179 53095 Main Road-SOUTHOLD,NEW YORK 11971 y�0 Town of So u th o l d CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) DOLES THIS PROJECT INVOLVE ANY OF THE FOLLOWING: Yes No (CHECK ALL THAT APPLY) ❑ . Clearing, grubbing, grading or stripping of land which affects more ❑[3/B. than 5,000 square feet of ground surface. Excavation or filling involving more than 200 cubic yards of material within any parcel or any contiguous area. ❑[G]'C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. , .❑[3'/D. Site preparation within 100 feet of wetlands, beach, bluff or coastal erosion hazard area. ❑a. Site preparation within the one-hundred-year floodplain as depicted on FIRM Map of any watercourse. ❑ff/F. Installation of new or resurfaced impervious surfaces of 1,000 square feet or more, unless prior approval of a Stormwater Management Control Plan was received by the Town and the proposal includes in-kind replacement of impervious surfaces. If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information, Date & County Tax Map Number! Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. APPLICANT (Property Owner,Design Prof essrowk/*tre- gent,Contractor,Other) S.C.T.M. #: 1000 Date Di�lnctJ 2 NAME 70 ,nZ,/ O�h r Section Block Lot l,gmiUrcl K'K K 7 FOIL. BUILDING DEI'j1RI KEN"1- USE ONLY - Gi;Ex; - ._[°c°^' - 'T,- ai NumbcrP• _ _ _ -;t^�a�'__- _ _ - .F_ - --°-<.c:'l_t;;a.~_ - ,-cr +,i - �_-t2 T-: ^c-L;.-alfd�•�v`_.-_ .•L"4a_,1L C,:i." _' •..�..r - _ '- _ - - - - - - - ���w,w� =- Reviewed_'B, :�_: - - - ,�=/''" �,:�-,: ,k.�'��:•r-- TT T— - '"��- �:=s' Y:v:.+c '_ _ '"J•^". •Pq:}1"-✓M-u••�Y"•SY'' _ - �:A;'__. __ .��� _ _ - -�+ "` - �y _- snJ,_.v',llm•__;�.s.. .a.4_ '_+1�_A�� ..� ��_ _— _ _ _ SAw'n��'.W.•, ``�e_ _ '_.= =<<:-..3.-. _'rn.,•:.C.��n3::: -+-1:-:s_. _ - �"T.err=- '%ie'�. *' c_ rYF'�;Y.t�:.-�`i:,-N::i - _ - _=Y i`':f.'..w.... - J,:a' ,?Y:;:i?'•�_ � :..-fir---•a-- '•�"5.-.—'^�= ate..;=,U-_ .;'t``';�a'�-� - -ma-�- •.:-cc.Y.cs�..,>.� ,',.�.•r- '�:t x='� - =::.�5.: �•1:-.::' [•Mw.n,.a=,-'..K"` - �F` - _- - - _ _ f•" `=;�=�.=:a,.��� � -- ax r ._�:�,k`- - - ;x:�,. - `_^•,��n/�o�_ ¢,�racessl[�Q Bna u -,1•tYevti,n���{SHY —-'s,••a. _ x _ _.-:J••c'K.��� - �,"-L�Y4'l- ,�'TTx:'^j� �[FY .��C�, _rL:n��F_��.�_„'.�✓wr _ �_-y>�Y':,_z'fr.=�-*`?�r�.�eM: -�-?` c4:3�=' -�-vv"``5:.�^�;,.^"::”" - ,?,:%j<::-- - -"?st'°-��_,xP.i - -7+-- - �•, - =:` ;«,r*1�^-: �_�..-�•i+rn•�-_'t_t--�_._ _ _ .,..sr.`a-c'��'��•. _ _ - _T- ,`,7=.-`�=`�3E'-'C�yvr.,�= ��_OC{T���C►<.. aE1 errie�'�uCoiit'r€it'�'lai"IVgt'�itequit?.eti'-:...;.„r��-"_�_1;,. _ te er;Mana - - Control.Plan. Ruird.__ - - - ,>> s ,rgement is e Req -= - - - - - Y:r _ - _ _ �.�--•p'==-a __ �at� :�ngf4cern�De"p; :.tis-•`-s`c`Si '.---"�`i'.^+�__ ��#..-.,...r.� �.�'..`cl t.:.+.riv:2'r•k`'.� — �.3.�.-- `rJ�'+_._�. _`Fa_ � " _ Ya•„>' _•^�Y•�'c _ - _- - - - ..x -•f---•_.,.: :.`. --•.�`:=,.�'.r.N ___ _ U �•'=�:; �u.;�.i_m.f,-�K'r�'r:,�'��<-,,ns x";.:�;'++'?4.- cS`-:ri.,�'__ _ _ - _=r.�re'�,-5.�.”,:_- .,_.G,L,.,....�.r.._�..r�.v=;, _ _ w.r,= -_..-:—.�__�,.s. ,......_ `�.:•1,�,,...:c::"a.v_.• �.r..._'�:.I:z;.'-.���,-+•�"': -- --.a+..a`�"a/'.".c - - 'y��i,_-�-_r�.%•w,._ mar.. _ r; �:y.0 ..-,Lc•,,�j-rr�� - -^�yp+���_��,:{e-��" c��/j,�;_��,t¢.y -- ' µ �{ ,(' -t - �P:-. _ _ _c'.e'z.. :.�*.�n-•` r.3-r:^..,.'.'� ��/1-; s3"3.� �r�� - > •a Z�._ _•�•r.=_ �3-'� :S=: •f.",&A"� ,P�i r �-:>�n'�"` -r,"- ' r'-`.'ra.o°9_;sa:ter..._ :.f-� _ =3f'_ ^3F _ .n.i-. �+-M`'c�•�.t,dm¢_v - __ - - - V^5':e:.^'. - n.^L... ri.._yd �,h-.. :.i'•:.:,i1.�s�F:' - ir`.. _ _ "4:�-: ':u��-` .u�-�,.ana=-�r�a�..�-�i,:._ w�;-e+.'n��":-��a k,_:.�.^.. ,.A', �•2•`��,��9 :.•:iia -ry-'-• `an.z� -f;'"' :,;�•k,ff:"=,• _ ��a{y�F - - - - S`- - __ -$�.., __ `4 G's;• Wit:`:"-"`-,•.'�..'.:y'i^.._� ,+rn�-n..��.�I-�,i_,Y9't� °T,�•` _ Y-"v{' _ _ -_,�. �-3r`a•_ __ {-a.. .�z�'-',� - - .c.r_-._r-e_._.'v .r �'=H�i.,r.,r_,:k"? '.w`v:1i:. - _ - -_� ��Mv...-.--..e.._..._.. 1_._ ._ •-its<R=. �t'i� tLr-=`.��-d.'T.-_S.�•.ai.. �i'�e .. .� _ _ -• _ - _ - M1 .z..e-...� _ _..�'I__-_�... `u:Y"•,_, .fi��. _— v ,ems.. - - i ....... .., �. a, .. .>�.. .� .. � .e+- 4 n'�: J Southold Town Building Department ®�guFFUd,�coG. P.O.Box 1179 Permit#: 39188 y 53095 Main Rd Co Southold,New York 11971 Permit Date: 9/16/2014 PA,l (631)765-1802 Expiration Date: 3/17/2016 Parcel ID: 70:10-28.3 BUILDING PERMIT RENEWAL LETTER Dated: 11/14/2018 Applicant: Southold LLC Location: 2350 Clearview Ave, Southold Work Description: HOT TUB install a Hot Tub upon an existing deck, ZBA decision#6690, as per State code barrier compliance A FEE OF $125.00 IS REQUIRED TO RENEW THIS BUILDING PERMIT. Owner: Southold LLC Address: 15439 Milan Way Naples,FL 34110 The permit listed above has expired. No work is permitted or authorized beyond the expiration date. Please submit the above fee made payable to the Town of Southold. Mail to the Town of Southold Building Department, P.O. Box 1179, Southold, New York 11971 THANK YOU, SOUTHOLD TOWN BUILDING DEPT. S.C.T.M. NO. DISTRICT: 1000 SECTION: 70 BLOCK: 10 LOT(S):28.3 z ._ z - o CLEARVIEW � BECQO�CK, MON E S 81-0 6 ENU 0 E 132.77p0'`P ""mr B MON ti MON CID CO c0 CIS DRI WAY 72.�• \49,5' N fi "RAS ry fsr� lfySf�� CV cc 90 \ Sao ,ar u.e ftw ae f1e., „m, Z STY,FRAME 20'�y \ Iz]SO C144. 'v a 31,5' Woworoc U.P. _——I➢6' w QA Fly, Sh'f0 O e,•E O �0 *00D RAI,FENCE A 0 � O `' UMIT OF O DDE iE c WA •.y A — � ApN �� •�• X71 •� �o A _ _ N 196643 48" c SHDREUNE 7.90'.1 2pl�f k r X80 36 57" S `DAY I r _27, I Z , r r r r 2R6—Alp . � „?`n\kMfy r r r r zs;,er ,Q, ��;tr�—'N ?¢. r�r`�Iwo ws ` • U.P. Air 5? r r r r �SAANc .�Q� �,Oi r Oj lye \ :•. ■zo o.oci ;w .--� r r r r 5� .--� r .— r r r r r r_Qy r12:' '.J ,s`•�-_ �, ••�;�r ;_ -. - . '- - , ,. - , r r r r --GOOSE CREEK r r r r r l CUAP�LL rrrrr .� .— C �(Q UG�OnJ ADD PROPOSED DECK & SPA 03-07-13 THE WATER SUPPLY, WELLS AND CESSPOOL LOCATIONS SHOWN ARE FROM FIELD OBSERVATIONS FIRM ZONE PANEL 166 AND OR DATA OBTAINED FROM OTHERS. AREA: 35,019.80 SQ.FT. or 0.80 ACRES ELEVATION DATUM- _________________________ UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPIES OF THIS SURVEY MAP NOT BEARING THE LAND SURVEYOR'S EMBOSSED SEAL SHALL NOT BE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED AND ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTITUTION, GUARANTEES ARE NOT TRANSFERABLE. THE OFFSETS OR DIMENSIONS SHOWN HEREON FROM THE PROPERTY LINES TO THE STRUCTURES ARE FOR A SPECIFIC PURPOSE AND USE THEREFORE THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE ERECTION OF FENCES, ADDITIONAL STRUCTURES OR AND OTHER IMPROVEMENTS. EASEMENTS AND/OR SUBSURFACE STRUEf'URES RECORDED OR UNRECORDED ARE NOT GUARANTEED UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF SURVEY SURVEY OF: DESCRIBED PROPERTY CERTIFIED TO: MICHAEL H. LLOYD; MAP OF: FILED: SITUATED AT: PINE NECK TOWN OF: SOUTHOLD KENNETH M. WOYCHUK L.S. SUFFOLK COUNTY, NEW YORK Land Surveying and Design y,� , P.O. Box 3, Mattituck, New York, 11952 FILE # 12-118 SCALE: 1 "=40' DATE: SEPT. 21, 2012 .�Al PHONE (631) 298-1588 FAX (631) 298-1588 N. Y. S. LIC N0. 50227 maintaining the records of Robert J. Hennessy REVISIONS: LL L 770 � w _ W w Q � w Q a W 88 I Nd- z P- w Mum Ir , , , ,. FRONT ELEVATION SCALE: 1/4" = V-0" O 7 x O w �D 0 r--� U o M N 2� or000 oouo • r�oo_ 00 �� 0 0 C\ cri v 0 � c' ° O x o @ °° `L o Q) m �\ o P "t ON v� �n 00 - a 01 F-D_ o 41.111 u w v..< ' z 01=1 Oo _ t= . __ t ; . - - Lam LEFT ELEVATION SCALE: 1/4" = V-011 A��. DRAWN: MH/MS SCALE: 1/4"=1'-0" JOB#: ch February 28,2014 " ? SHEET NUMBER: PAINTER 70 PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS A- 1 _ MANUFACTURER'S WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. REVISIONS: �l D I O HHM � Q � C a Q W . ♦ i� O // ♦♦ ` d.: .iT:.'Y'1.',.}. A"„I" .'”�':..,, .� .`i"�wa :,i +.;.. ". "...i'." IEEE / ♦ '`S �� tr A.. fin.."fes£::-,... }.' ";.Af_i.' 1 �- 41 E 11 EN4 177 L L C \ / ♦ I _ Irl O REAR ELEVATION W o 5x SCALE: 1/4" = V-0" p UO o M N 0 N w m rn �. V �p c7 c2l p X O V U) V V � U a� 2X8 ACQ BENCH oo LEDGER 5/4"DECKING + LEDGER \ W 2X8 ACQ DJ @16"OC - 5/4"DECKING t 2X8 ACQ DJ @16"OC ' (3)2X10 ACQ (2)2X1 ACQ (2)2X10 ACQ GIRDER ACQ a•: N . GIRDER GIR ER v° o 4 cV EXISTING 10"DIA. 10"DIA. '•° W a a O 10"DIA. = 10"DIA. CONC. CONC. ti•• CONC. c CONC. e O PIER a.•' PIER a•' PIER t• PIER • --_ 0 VJ SECTION A-A SECTION B-B SCALE: 1/4" = V-0" SCALE: 1/4" = V-0" u -_%,�mow",•<F�.rs•.a Ct>�\. rtk` 1, •� i F -f' �t DRAWN: MH/MS SCALE: 1/4"=V-0" JOB#: February 28,2014 F^„w.;•a;�r SHEET NUMBER: PAINTER TO PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS A-2 MANUFACTURER'S WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. REVISIONS: NEW EXIST 5'-0'/211 11'-0" A 10 5'-01/2" I 1 —0" 9'-0" 0 1'— -- ------------------------- 1 14"DIA.CONC.PIER 1 I AS BUILT DECK i Cdr�� nl a /2X8 ACO DJ ,,a 1 ------------------------- O @16"OC J nIQ I,I I z 1 , v I,I , x X x 1 ry/ 111 N III ' IIIN ' N PROPOSED DECK I N /� N ►� a (MATCH EX.DECKING) / p , Q ' Ua/ q,q nl nI ' O ; ��I 10"DIA.CONC.PIER � O T BELOW GRADE(TYP.) iiia r w X IIIA 1 N ,11 1 1 ,IIx 1 ,� IIIx2X8 ACO ' @16 OC nl nIN ►-� (z)zxio ACQ H 1` 4,-0" 1 — w^ I— if IF-- ' O 0 o i 0 A w 0 o. :o o_ cc @ I 1 co 1 1 I 1 1 10'-0" 4'-0" 0 10'—0" 4*—010 0" 6'—0 0 " (2)2X10 ACQ O o o =p J ,35 N I ' 6 ' d ,� >cb W I I 1 --------------------------- -'' vly BENCH(MATCH EXISTING) ------------------- I I 1 (2)2X10 ACQ cO 1 1 1 1 I 1 1 1 I I I , 1 I I 1 ^ I 1 I t O �'f'' � O I I 1 O $ I I 1 d 1 O PROPOSED DECK < 10"DIA.CONC.PIER (MATCH EX.DECKING) O , �� U (2)2X10 ACQ 3'BELOW GRADE(TYP.) ----------------------------------------------------- � --- ---------------------- ---------------------- -------------------=-_-_-_-_- --- --------------------- (2)2X10 ACQ - O - M N 1 1 I I I 1 I 1 1 1 1 I 1 I I I I I 1 I I I T I =II II= T 1 I , •----- jKJ ' N ' 1 N LK HOT TUB 1 8'X8' ' DW u.is �, I INSTALL PER 1 a l HOT TUB 1 a MANUFACTURER _____ ; ¢I; INSTALL ON PAD PER 1, ¢ -0-) - ' x MFGRS.INSTRUCTIONS :goo O 1 I 1 O 1 I , I I 1 1 I 1 m 1 1 II ^ CC", m 0 ====0 == ===============-+ --====(2)2x1oAcQ=====_= o Ln 2'-4" : '0 219 --------------------------- -- ----------------------0_. 20'-0 I I w I I 20'-0" cu 0 00 II � � 'u" " II IIlz U NOTE: EE 00 N v PROVIDE HOT TUB WITH A SAFETY COVER WHICH COMPLIES W t~ WITH ASTM F 1346,AS PER NYS CODE. IF COVER IS NOT TO BE USED PROVIDE BARRIER PROTECTION REQUIREMENTS AS PER N.Y.S.RESIDENTIAL CODE: 1).TO OF RAILING TO BE 48"(MIN.)ABOVE GRADE. oJu W 2).BAULASTERS SHALL NOT ALLOW PASSAGE OF A 4"DIA. SPHERE. u I 1 3).ACCESS GATES SHALL COMPLY WITH NYS CODE. Y' ' 1 �I o un I 4).GATE TO BE SELF-CLOSING&SELF LATCHING FOUNDATION PLAN �1 O 1 ' 5).DOORS ACCESSABLE TO DECK TO BE SELF-CLOSING& ; o ; 1 SELF-LATCHING. 1 o ' --- SCALE: 1/4" = V-0' " ; 1ST. FLOOR PLAN x SCALE: 1/4" = 1'-0' k` o' ; `1 DRAWN: MH/MS 3, y 'r SCALE: 1/4"=V-0" JOB#: February 28,2014 SHEET NUMBER: PAINTER TO PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS A-3 MANUFACTURER'S WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. REVISIONS: WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS USE THE FOLLOWING OR APPROVED USP METAL CONNECTORS FOR PROPER WIND RESISTANT CONSTRUCTION. FOLLOW MANUFACTURE'S RECOMMENDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY. 4"MAX. 4"MAX. 4" DIA.MAXIMUM 4"DIA. MAXIMUM POST GIRDER/HEADER 0 Z :o rn POST/COLUMN ', 12"x12"x12" V V Y CONCRETE FOOTING zo c�� civ Y \ Y , M V Y ° v v DECK POST FTG. CONNECTION COODECK/PORCH RAILING LOCATION USP NUMBER DESCRIPTION APPLICATION POST-TO-GIRDER/HEADER CONNECTION 4X4 POST PAU44 OR WE44 POST/BEAM ANCHOR APPLY TO EACH FOOTING USE MIN. (2) 1/2"DIA.GALV. BOLTS WITH WASHERS AND NUTS Q STAIR RAILING 6X6 POST PAU66 OR WE66 POST/BEAM ANCHOR APPLY TO EACH FOOTING Z r 1 o�j 1-1/2"SPACE MINIMUM ^W ~ H W Q HANDRAILS W Z GIRDER O U POST GIRDERMEADER o • O . , •. z RIM/DECK 101ST POST/COLUMN •. ; •, p..l U BALUSTERS o CONCRETE PIER • o ',�� W OPEN BALUSTER ATTACHED TO WALL ` HANDRAIL CONNECTION ALL HANDRAILS SHALL BE CONTINUOUS THE FULL LENGTH POST-TO-DECK CONNECTION HEADER/GIRDER-TO-POST CONNECTION OF THE STAIRS. HANDGRIP PORTION OF ALL HANDRAILS SHALL NOT BE LESS THAN 1-1/4"NOR MORE THAN 2" IN LOCATION USP NUMBER DESCRIPTION APPLICATION CROSS SECTIONAL DIMENSION,OR THE SHAPE SHALL USE MIN. (2) 1/2" DIA.GALV. BOLTS WITH WASHERS AND NUTS (2) BEAMS PAU44 OR WE44 POST/BEAM ANCHOR APPLY TO EACH PIER PROVIDE AN EQUIVALENT GRIPPING SURFACE GIRDER/HEADER TO POST/COLUMN CONNECTION (3) BEAMS PAU66 OR WE66 POST/BEAM ANCHOR APPLY TO EACH PIER FLASHING TUCKED UNDER W TOP PIECE OF SIDING AND LAPPED OVER FIRST CONTIN. [� GIRDERMEADER PIECE OF SIDING BELOW J UNDISTURBED SOIL � LAY PLASTIC BASE DIRECTLY ON O 2 -1/2"DIA. LAG BOLTS W/WASHERS UNDISTURBED SOIL(ORGANICS REMOVED) W A CONNECTED TO BLDG. @32"OC LEVEL BASE O STAIR TREAD ° o FIT CONSTRUCTION TUBE AND PLUMB > POST/COLUMN BRACE TUBEW RIM BOARD ° ° FILL AS PER MANUFACTURES'INSTRUCTIONS >_1 U Q FLOOR FRAMING 1 p STRINGER 2x JOISTS III=111=III= _ _ _ _ =III=III- h--1 vn III_III_III=III_III_III_III_III_III=11 N BLOCKING FOR JOIST HANGER POST-TO-GIRDER/HEADER CONNECTION LAG BOLTS p e p P LOCATION USP NUMBER DESCRIPTION APPLICATION IRIM JOIST/BD. e 4x4 SOLID COLUMN PBS44/PBSE44/KC44 POST CAP ANCHOR APPLY TO EACH COLUMN �° DISTURBED/POOR SOIL 6x6 SOLID COLUMN PBS66/PBSE66/KC66 POST CAP ANCHOR APPLY TO EACH COLUMN LAY 4-6"LAYER OF CRUSHED STONE OR STRINGER TO DECK/PORCH CONNECTION HOLLOW COLUMN SIMPSON STRRI/2 H.C. ANCHOR APPLY TO EACH COLUMN GRAVEL DECK/PORCH LEDGER CONNECTION LEVEL AND COMPACT BY HAND 0 LAY PLASTIC BASE ON COMPACTED GRAVEL „ LEVEL BASEm N FIT CONSTRUCTION TUBE AND PLUMB rn BRACE TUBE o ,n U FILL AS PER MANUFACTURES'INSTRUCTIONS as rn o 0 R" rr w@ __ 1 =III=III=11= 11=II=1I =III= 11= -� z lu III-III-III=III-III-III-III-III-III-1100 v LO lu 0 �H v VfVCOD JOIST WOOD JOIST JOIST U U BLOCKING CONC. PIER FOOTING00 ci BIGFOOT SYSTEMS FOOTING FORM ori] GIRDER/HEADER IN ACCORDANCE WITH SECTION 104.11 OF N.Y.S. RESIDENTIAL CODE THIS DESIGN WOOD GIRDER COMPLIES WITH THE INTENT OF THE CODE AND THE MATERIAL OFFERED IS WOOD JOIST GIRDER/HEADER AT LEAST THE EQUIVALENT IN DURABILITY AND EFFECTIVENESS OF THAT PRESCRIBED IN THE CODE. THE DIVISION OF CODE ENFORCEMENT AND ADMINISTRATIONS FINDS THIS PRODUCT ACCEPTABLE FOR USE IN N.Y.S. BASED UPON ICBO EVALUATION SERVICE REPORT W FLUSH JOISTS WITH HEADER/GIRDER ER-5495 AND SUBJECT TO THE CONDITIONS THEREIN. SPLICED JOISTS OVER HEADER/GIRDER ALL JOISTS CONNECTED TO A FLUSH HEADER TO BE SUPPORTED WITH THE PROPER STEEL CONNECTOR. SPLICED JOISTS OVER HEADER✓GIRDER PROVIDE BLOCKING BETWEEN JOISTS THAT ARE SPICED AND U IF ABLE,SET FIR JOISTS APROX. 1/4"HIGHER THAN LVL HEADERS LOCATION USP NUMBER DESCRIPTION APPLICATION USE WITH RT10 TYDOWN ANCHORS O TO ALLOW FOR SHRINKAGE. JOIST TO GIRDER/HEADER I RT10 ITYDOWN ANCHOR ICONNECT TO EACH JOIST N DECK& PORCH NOTES: NAILING SCHEDULE 1). Unless otherwise noted,all framing material to be#1 ACQ pressure treated lumber. NAIL NAIL All fasteners, hangers and anchors to be galvinized or stainless steel. JOINT DESCRIPTION QT.. SPACING NOTES U 2).Girders for deck joists to be bolted or anchored to each post or pier with washers and nuts. JOIST TO: 4-8d COMMON PER TOE � Girders on concrete piers shall be anchored with proper steel connectors anchored SILL,TOP PLATE OR GIRDER JOIST NAIL into concrete with a minimum 1/2"dia x 7"long anchor bolt with washers and nuts. CLIMATIC&GEOGRAPHIC DESIGN CRITERIA BRIDGING EACH TOE GROUNDWIND SEISMIC FROST WINTER ICESHIELD TO JOIST 2-8d COMMON END NAIL 3). Posts supporting girders shall be anchored to a 12"x12"x12"thick concrete footing. FLOOD BLOCKING EACH TOE R E 2-8d COMMON Use a minimum 1/2"dia x 7"long anchor bolt with washers and nuts. Footings Shall SNOW SPEED DESIGN WEATHERING LINE TERMITE DECAY DESIGN UNIRED NT HAZARDS TO JOIST END NAIL be 4 ft.below grade. LOAD (MPH) CATEGORY DEPTH TEMP. REQUIRED BLOCKING TO: EACH TOE MODERATE SLIGHT TO 3 -16d COMMO 4). Deck joists to have blocking at 8'0 o.c.. 45 LBS. 120 B SEVERE 3 FT. 11 NONE - SILL OR TOP PLATE BLOCK NAIL / g TO HEAVY MODERATE ,.,j �; LEDGER STRIP EACH FACE = ' 3 -16d COMMON ";,;• .; ` 5).A minimum of 10 inch flashing shall be installed between the building and ledger. TO BEAM JOIST NAIL Ledger to be fastened to building with 1/2"dia. bolts with washers and nuts �."G► �s` `� , JOIST ON LEDGER PER TOE TO BEAM 3 -8d COMMONJOIST NAIL at 16"o.e. e BAND JOIST PER END $ �0 DRAWN: MH/MS 6).Concrete piers shall be a minimum 6"above rade. 3 -16d COMMO f " P g TO JOIST JOIST NAIL :< SCALE: 1/4"=1'-0" 7).All joists to be supported with hangers and anchors. Each Joist shall also be anchored BAND JOIST TO: PER ' .•$ SILL OR TOP PLATE 2 -16d COMMO FOOT TOE NAIL '> JOB#: to girder(s). February 28,2014 8). Use simpson hangers and anchors with Z-MAX tripple protective coating or equal ' SHEET NUMBER: r=• for any contact with ACQ. PAINTER TO(PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS A-4 MANUFACTU'RER'S WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS.