Loading...
HomeMy WebLinkAbout42410-Z µ F04c0 �� Town of Southold 3/25/2019 g P.O.Box 1179 0 y T 53095 Main Rd d4,, ao�� Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 40279 Date: 3/25/2019 THIS CERTIFIES that the building ALTERATION Location of Property: 4405 S Harbor Rd., Southold SCTM#: 473889 Sec/Block/Lot: 87.4-6.3 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 2/21/2018 pursuant to which Building Permit No. 42410 dated 2/23/2018 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued.is: WINDOWS, DOORS AND CENTRAL AIR CONDITIONING TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Emry Realty LLC of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 42410 03-22-2019 PLUMBERS CERTIFICATION DATED V?� A th ' d Signature o� TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42410 Date: 2/23/2018 Permission is hereby granted to: Emry Realty LLC 2855 Laurel Trl Laurel, NY 11948 To: replace windows and doors to existing single-family dwelling as applied for. At premises located at: 4405 S Harbor Rd., Southold SCTM # 473889 Sec/Block/Lot# 87.-1-6.3 Pursuant to application dated 2/21/2018 and approved by the Building Inspector. To expire on 8/25/2019. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $200.00 CO -ALTERATION TO DWELLING $50.00 Total: $250.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of I%lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant.If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00,Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential $15.00,Commercial$15.00 Date. F�b R 26 IS New Construction: Old or Pre-existing Building: X (check one) Location of Property: ut 40 H*A-Bug- 9,b, S 0 0 �hi4 U1J ley �-7 House No. Street Hamlet Owner or Owners of Property: l:-m Suffolk County Tax Map No 1000, Sections"� , Block , Lot --f;o. 3 Subdivision Filed Map. Lot: Permit No. Lh Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate:��(check one) Fee Submitted: $ 16(7 Applicant Signa re Town Hall Annex ® Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 'c® �® roger.richert(cD_town.SOUthoId.ny.us ff V I BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To* Emry Realty LLC Address: 4405 South Harbor Rd City Southold St- New York Zip: 11971 Budding Permit# 42410 Section 87 Block 1 Lot 6.3 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE contractor: DBA. Hubbard Electric License No: 4708-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage X INVENTORY Service 1 ph Heat Duplec Recpt Ceding Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser 2 Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower 2 Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches Twist Lock Exit Fixtures 11 TVSS F1 Other Equipment 2 central air conditioning units, 2-condensers, 2-air handlers Notes, Inspector Signature: Date: March 22 2019 81-Cert Electrical Compliance Form As SOF so o� # TOWN OF SOUTHOLD BUILDING DEPT. �ycou765-1802 = INSPECTION - [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] SULATION ,,pp [ ] FRAMING /STRAPPING [ FINAL VJIt�� 10"'0 [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: �n �! 1�1✓L O �✓ &M IOU I v/ m4 w4 . y DATE ( t I INSPECTOR OF SOplyolo TOWN OF SOUTHOLD BUILDING DEPT. courm 765-1602 INSPECTION .,[ ] FOUNDATION 1ST [ ] ROUGH PLEG. [ 2-4 ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: KIAi (� DATE �' 2 ( INSPECTOR'�Z FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(IST) ------------------------------------ t FOUNDATION (2ND) ®� Z _ O ® �, ROUGH FRAMING& y PLUMBING 1 INSULATION PER N.Y. H STATE ENERGY CODE s �o✓ ArQi -- dl w ✓ S "o FINAL LOOF ADDITIONAL COMMENTS -a�- --J:ka s _ - re ULTLIS o � rn � O d b H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631)765-1802 Planning Board approval _ FAX: (631)765-9502 `� Suryey Southoldtownny.gov PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees D O'V C.O.Application [ECF Flood Permit Examined O\� 20 [E D Single&Separate Truss Identification Form FEB 2 1 2018 Storm-Water Assessment Form Contact: JA Al 9E!; M 0 t/Nd y Approved ,,\-r2- ,20� SMDM a e Mail to: F® {yrs 13 7 TOWN OF SOUMOLD Disapproved a/c 74tme,- P&-r c047 Phone: &-3 742-12-G i Expiration ,20 B t±01-14 m ector APPLICATION FOR BUILDING PERMIT Date 120 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws, ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. Ina vi ec&r &Jwg �.zzJ (Signatuf of applicant or name,if a corporation) z%55 4-2vYeJ -r7:?- L4,V_re r72L ,V_re/ /viI I I q 4&, (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder 0Wtje_e Name of owner of premises E�IM AY (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. LL4 ocation of land on which proposed work will be done: House Number Street Hamlet County Tax Map No. 1000 Section p Block ( Lot z i Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy R F6 l b 15-1y Tt kL.. H-o Ak43- b. Intended use and occupancy P C',>1 -pF—OUT[6 4- 3. Nature of work(check which applicable): New Building Alteration Repair Removal Demolition Other!"W0155' Aeezare W1 cV-o wS k-lN b (Description) S510vv1y 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO-A 13. Will lot be re-graded?YES NO_ Will excess fill be removed from premises?YES NO 14.Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO x * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO� * IF YES,PROVIDE A COPY. STATE OF NEW YORK) ��? ��YS�S: COUNTY OFSjR2' �aQ-ftEs m o aj�_'.y being duly sworn,deposes and says that(s)he is the applicant (Name of individual sign g contract)above named, (S)He is the /✓ QYtcLMe 171 b'r Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this v� Q day ofJYJCLAU 242-5 Notary ubli . licant DWYER NOTARY PUBLIC,STATE OF NEW YORK Signature of App NO.01 DW6306900 QUALIFIED IN SUFFOLK COUNTY COMMISSION EXPIRES JUNE 30,26tg P ��..4',� "'r`'}r,�.,,,'• °� $. -r.'s•,'p�, ;fir.,N,.,, Q UILDING DEPARTMENT "a��a3�IV.,��`'.•`g_•1V ��� ,�s:,.x=�� � F � <<�::.• ";;; j x �"w,. ,. A>.p',,e,v�,f<^u'�R���''1',aah3.^£, o TOWN OF SOU S , 6 `� • t� �;� '_' 71-1 ��...:.,_uVTown Hall Annex - 54375 Main,— YY Southold, New ork e (631) 765-1802 honnr. �, :... tV. n 7ftQo° ns�' er.richert towS® ro X. �3w. :: Z. -•l;Se,. APPLICATION FOR ELECTRICAL INSPECTION �i'�I C dYi ! )G� Date: 0 31 v C ) rREQUESTED BY: v h�2a V';C . �-mpany Name: abEc�< I 14-C- Name: tlVl t 'L4 064- �L c�p�o�tl�rre License No.: � O � e 40 mail: Address: v�H"�� � I Lam( � Phone No.: JOB SITE INFORMATION: (Alt Information Required) a LL Mame: A Address: Cross Street: ► OJ Phone No.: S 1 - -? BIdg.Permit#: I-� z-�} l O email: nr<ovj d, (CE, o a i via.- n Tax Map District: 1000 Section: P Block: f Lot: BRIEF DESCRIPTION OF WORK (Please Print Clearly) A-k (2- Condeo& �-t i2 ry iJ(�• Circle All That Apply: Final Is job ready for inspection?: _ YES NO Rough In Do you need a Temp Certificate?: YES /� Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: = # Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect- Service Reconnected - Underground-Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Form AS � U A .PR VED AS NOTED N T Aoad DATE: 023 B.P:# -FEE: BY: NOTIFY BUILDING DEPAftM9NT AT 765-1802 8 AM TO 4 PM FOR THE FOLLOWING�INSPECTIONS: 1. FOUNDATION: TWO REQUIRED FOR POURED CONCRETE 2. ROUGH = FRAMING & PLUMBING 3. INSULATION Andersen 4r Indows-Abbreviated Quote Report Andersen. FINAL-- CONSTRUCTI®� §f BE COMPLETE FOR C.O.Project Name:jim mowdy Quote#: 1616 0/ uote Date: 02/14/2018 iQ Version: 17.2 Dealer: RIVERBUILD BUILDItt�� ENTS OF THE CODES OF NEVBilling Cusmer: BUILD SMARTER.B�JI �jM 1-800-378-3650 YORK STATE. NOT RESPONSIBLE FOF Address: WWW.RBSCORP.C( SIGN OR CONSTRUCTION ERRORS Phone* Fax: Sales Rep: TERRY McCAB�'`- Contact: Created B : Trade ID: Promotion Code. Item My Item Size(Operation) Location 0001 12 TW3052(AA) west wall rd.side south east north _ walls 1st.ilr. G RO Size=3'21/8"W x 5'4 7/8"H Unit Size=3'1 5/8"W x 5'4 7/8"H F-7400 Series —'� Unit,Equal Sash,White/PI White,(Top Sash)High Performance Low-E4 Glass,Divided Light with Spacer,Specified Equal Lite,3w2h,7/8",High Definition —�i Chamfer,Chamfer,Ext Grille-White,Int Grille-Pretmished White(Bottom Sash)High Performance Low-E4 Tempered Glass Viewed from Exterior Insect Screen,White Zone:North-Central U-Factor.0.31, SHGC:0.28, ENERGY STAR®Certified No - 0003 1 TW30310(AA) east 1st fir. ` RO Size=T2 1/8"W x 4'0 7/8"H Unit Size=T11 5/8"W x 4'0 7/8"H _ —� 400 Series j Unit,Equal Sash,White/PI White,(Top Sash)High Performance Low-E4 Glass,Divided Light with Spacer,Specified Equal Lite,3W2H,7/8",High Definition Chamfer,Chamfer,Ext Grille-White,Int Grille-Prefinished White(Bottom Sash)High Performance Low-E4 Glass --- Insect Screen,White Viewed from Exterior Zone'North-Central U-Factor,0 31, SHGC:0 28, ENERGY STAR®Certified No Quote#: 161656 Print Date: 02/20/2018 Page 10f 6 iQ Version. 17.2 COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES OCCUPANCY OR AS REQUIRED AND CONDITIONS OF �etleaa� USE IS UNLAWFUL S WITHOUT CERTIFICATE. WN TR ES OF OCCUPANCY . . .DEC Item Oty Item Size(Operation) Location 0004 1 TW2436(AA) east bath list fir. 'HT RO Size=2'61/8"W x 3'8 7/8"H Unit Slze=2'5 5/8"W x 3'8 7/8"H Series Unit,Equal Sash,White/PI White,(Top Sash)High Performance Low-E4 Glass,Divided Light with Spacer,Colonial,3W2H,7/8",High Definition Chamfer, Chamfer,Ext Grille-White,Int Grille-Prefinished White(Bottom Sash)High Performance Low-E4 Glass Insect Screen,White Viewed from Exterior Zone:North-Central U-Factor,0.31, SHGC.0.28. ENERGY STAR®Certified No 0005 1 C235(LR) kitchen j RO Size=4'0 1/2"W x 3'5 3/8"H Unit Size=4'0"W x 3'413/16"H 400 Series Unit,White/White-Factory Painted,LR Handing,(All Sash)High Performance Low-E4 Glass,Divided Light with Spacer,Specified Equal Lite Fractional ��_- -- with Check Rail,7lites,3w2h,Center Bottom Horizontal Placement,3/4"with 1 1/8"Check Rad,Ext Grille-White,Int Grille-Prefinished White Insect Screen,White Viewed from Exterior Hardware Pack,PSC,Contemporary Folding-White Zone:North-Central U-Factor•0.29, SHGC:0.26, ENERGY STAR®Certified:Yes Quote M 161656 Print Date: 02/20/2018 Page 201' 6 10 Version: 17.2 Item Oty Item Size(Operation) Location -- 0006 1 FWG6068(SR) east 1st fir. ;i RO Size=6'0"W x 6'8"H Unit Size=5'111/4"Wx6'71/2"H 400 Series Frame,SR Handing,White/PI White Stationary Panel,White/PI White,High Performance Low-E4 Tempered Glass,Divided Light with Spacer,Colonial,3W5H,7/8",Ext Grille-White,Int Grille -Prefinished White Viewed from Exterior Operating Panel,White/PI White,High Performance Low-E4 Tempered Glass,Divided Light with Spacer,Colonial,3W5H,7/8",Ext Grille-White,Int Grille-Prefinished White Gliding Insect Screen,White Hardware Trim Set,GD,2 Panel,Tribeca-White Zone:North-Central U-Factor.0.32, SHGC:0.23, ENERGY STAR®Certified.No 0008 2 TWT3021(F) north 1 st fir,transom RO Size=3'21/8"W x 2'3 7/8"H Unit Size=3'1 5/8"W x 2'3 5/16"H i 400 Series Unit,White/PI White,High Performance Low-E4 Glass,Divided Light with Spacer,Specified Equal Lite,3w2h,7/8",High Definition Chamfer,Chamfer,Ext Grille-White,Int Grille-Prefinished White Zone:North-Central Viewed from Exterior U-Factor:0.28, SHGC 0.29, ENERGY STAR®Certified*Yes Quote M 161656 Print Date: 02/20/2018 Page 3Of 6 iQ Version: 17.2 Item Qty Item Size(Operation) Location 0009 1 TW3052-2(AA-AA) east 1st fir. L"T- ROSize=6'37/8"Wx5'47/8"H Unit Size=6'3 3/8"W x 5'47/8"H 400 Series Composite Unit,White/Pre-finished White,High Performance Low-E4 Top/Bottom'High Performance Low-E4 Top/Bottom Glass,Divided Light with Spacer Top`No Grille(s)Bottom'Divided Light with Spacer Top'No Grille(s)Bottom,Mulling Location:Factory(Direct),Mull Type-Narrow Mull,Mull Priority:Vertical Insect Screen,White Viewed from Exterior Zone.North-Central Unit U-Factor SHGC ENERGY STAR®Certified 1 0.31 0.28 No 2 0.31 028 No 0010 2 TW2436(AA) south mb.2nd flr.geust bath RO Size=2'6 118"W x 3'8 7/8"H Unit Size=2'5 5/8"W x 3'8 7/8"H 400 Series Unit,Equal Sash,White/PI White,(Top Sash)High Performance Low-E4 Glass,Divided Light with Spacer,Colonial,3W2H,7/8",High Definition Chamfer, Chamfer,Ext Grille-White,Int Grille-Prefinished White(Bottom Sash)High Performance Low-E4 Glass Insect Screen,White Viewed from Exterior Zone'North-Central U-Factor:0.31, SHGC:0.28, ENERGY STAR®Certified*No Quote#: 161656 Print Date: 02/20/2018 Page 4Of 6 IQ Version: 17.2 Item Oty Item Size(Operation) Location 0011 3 TW3046(AA) south msater east guest 2nd fir. RO Size=3'2 118"W x 4'8 7/8"H Unit SIze=3'1 5/8"W x 4'8 7/8"H 400 Series Unit,Equal Sash,White/PI White,(Top Sash)High Performance Low-E4 Glass,Divided Light with Spacer,Specified Equal Lite,3w2h,7/8",High Definition i) Chamfer,Chamfer,Ext Grille-White,Int Grille-Prefinished White(Bottom Sash)High Performance Low-E4 Glass Insect Screen,White Viewed from Exterior Zone:North-Central U-Factor 0.31, SHGC:0.28, ENERGY STAR®Certified No i— (f 0012 2 TW24310(AA) east master 2nd fir. RO Size=2'6 1/8"W x 4'0 7/8"H Unit Size=2'S 5/8"W x 4'0 7/8"H IIII' 400 Series Unit,Equal Sash,White/PI White,(Top Sash)High Performance Low-E4 Glass,Divided Light with Spacer,Colonial,3W2H,7/8",High Definition Chamfer, Chamfer,Ext Grille-White,Int Grille-Prefinished White(Bottom Sash)High Performance Low-E4 Glass Insect Screen,White Viewed from Exterior Zone:North-Central U-Factor.0.31, SHGC:0.28, ENERGY STAR®Certified:No -- 0013 1 CX14(L) north 2nd.fir, , ROSIze=2'8"Wx4'01/2"H UnitSlze=2'71/2"Wx4'0"H 400 Series Unit,White/White-Factory Painted,L Handing,High Performance Low-E4 Glass,Divided Light with Spacer,Specified Equal Lite Fractional with Check Rail,7 lites,3w2h,Center Bottom Horizontal Placement,7/8"with 2 1/4"Check Rail,Ext Grille-White,Int Grille-Prefinished White -- Insect Screen,White Viewed from Exterior Hardware Pack,PSC,Contemporary Folding-White Zone.North-Central U-Factor:0 29, SHGC.0.26, ENERGY STAR®Certified Yes Quote#: 161656 Print Date, 02/20/2018 Page 5Of 6 iQ Version: 172 Item Qty Item Size(Operation) Location Total Load Factor Customer Signature 6.831 Dealer Signature All graphics viewed from the exterior "Rough opening dimensions are minimums and may need to be Increased to allow for use of building wraps or flashings or sill panning or brackets or fasteners or other Items. Ask to see If all of the products you purchase can be upgraded to be ENERGY STAR®certified. SEEM 19 This image Indicates that the product selected is certified in the US ENERGY STAR®climate zone that you have selected. Data is current as of May 2017 This data may change over time due to ongoing product changes or updated test results or requirements.Ratings for all sizes are specified by NFRC for testing and certification Ratings may vary depending on the use of tempered glass or different grille options or glass for high altitudes etc Nexia is a registered trademark of Ingersoll Rand Inc. Project Comments: Riverhead Building Supply offers a two year parts and labor warranty on any Andersen Window or Patio Door products ordered through any of our locations. See your Riverhead sales associate for more details. Quote#: 161656 Print Date: 02/20/2018 Page 601' 6 IQ Version. 17.2 .m2o Quote Form Page 1 of 5 Quote Form RIVERHEAD-CALVERTON 962 BURMAN BLVD MRIVERIMUD CALVERTON NY 11933 Bead Sumder.LDS Better 800-378-3650 Project Information (ID#2153349) Hide Project Name:jim mowdy Quote Date: 02/14/2018 Customer: Submitted Date: Contact Name: PO#: Phone(Main): Phone(Cell): Sales Rep Name: terry mccabe Customer Type: Terms: Delivery Information Hide Shipping Contact: Comments: Shipping Address: City: State: Zip: Unit Detail Hide All ConfieurationOptions ASO"S2050-5Btff-I*W4-9ft&-- 1 Smooth Star 36"x80" Single Door 1,064.06 .7PA,"j '+rye Configuratio ptions Hide • Product Category: E rior Doors • Manufacturer: Reeb-S oth Star H%TMOR ' Product Material:Smooth S Fiberglass Right-Handlnswing • Material Type:Smooth Star • Product Type: Exterior • Brand:Therma-Tru • Configuration (Units viewed from Exterior): gle Door • Reeb Finish: No • Slab Width: 36" • Slab Height: 80" • Product Style: French https://m2o.edgenet.comNiewProjects/GetBasicQuoteFinished?ProjectId=2153349&ts=63... 2/14/2018 •m2o Quote Form Page 2 of 5 • lass Type: Clear • GI s Style:SDL • Glazi Type: Flush Glazed • Insulati : Low E • Grille Typ •SDL Standard Profile • Model:S20 -SDLLE • Frame Materia - FrameSaver • Handing: Right H d Inswing • Casing/Brickmould ttern: None • Hinge Type: Radius x S are (Self Aligning) • Hinge Brand:Therma-Tr • Hinge Finish: Brushed Nicke • Jamb Depth:4 9/16" • Sill: Composite Adjustable • Sill Finish:Satin Nickel w Light Cap • Multi-Point Lock: None • Bore:Single Lock Bore 2-3/8" Backset • Strike Jamb Prep: No • Weatherstrip Type: Compression • Weatherstrip Color:White • Custom Height Option: No • Kick Plate: None • Sill Cover: No • Rough Opening Width: 38 1/2" • Rough Opening Height: 82 1/2" • Total Unit Width(Includes Exterior Casing): 37 5/8" • Total Unit Height(Includes Exterior Casing): 82" Item Total:$ 1,0 .06 Item Quantity Total: $ 1,064. Item:0003:Ext 36"x 80"S2000-3C-SDL RHI 4 9/16"FrameSaver Location: Quantity:1 Smooth Star 36"x80" Single Door 814.00 Configuration Options Hide • Product Category: Exterior Doors • Manufacturer: Reeb-Smooth Star EXTIItIOR • Product Material:Smooth Star Fiberglass Right-HaudIw%ing • Material Type:Smooth Star • Product Type: Exterior https://m2o.edgenet.comNiewProjects/GetBasicQuoteFinished?Projectld=2153349&ts=63... 2/14/2018 m2o Quote Form Page 3 of 5 • Brand:Therma-Tru • Configuration (Units viewed from Exterior): Single Door • Reeb Finish: No • Slab Width: 36" • Slab Height: 80" • Product Style: Craftsman Style Lite • Glass Type: Clear • Glass Style:SDL • Glazing Type: Flush Glazed • Insulation: Insulated Glass • Grille Type: SDL Standard Profile • Model:S2000-3C-SDL • Frame Material: FrameSaver • Handing: Right Hand Inswing • Casing/Brickmould Pattern: None • Hinge Type: Radius x Square (Self Aligning) • Hinge Brand:Therma-Tru • Hinge Finish: Brushed Nickel " • Jamb Depth:4 9/16" • Sill: Composite Adjustable • Sill Finish:Satin Nickel w Light Cap • Multi-Point Lock: None • Bore: Single Lock Bore 2-3/8" Backset • Strike Jamb Prep: No • Weatherstrip Type: Compression • Weatherstrip Color:White • Custom Height Option: No • Kick Plate: None • Sill Cover: No • Rough Opening Width: 38 1/2" • Rough Opening Height: 82 1/2" • Total Unit Width(Includes Exterior Casing): 37 5/8" • Total Unit Height(Includes Exterior Casing):82" Item Total: $ 814.00 Item Quantity Total:$814.00 Item:0004:Ext 10"/36"/30"x 80"52000SL/S4816-SDLFlLE/S2000SL RHI 4 9/16" Location: Quantity: FrameSaver 1 Smooth Star 36"x80" Single Door w 2 Sidelites 1,731.38 s r,. kn https://m2o.edgenet.comNiewProjects/GetBasicQuoteFinished?Projectld=2153349&ts=63... 2/14/2018 m2o Quote Form Page 4 of 5 Configuration Options Hde • Product Category: Exterior Doors • Manufacturer: Reeb-Smooth Star FX=OR . Product Material:Smooth Star Fiberglass Ri*-H-d I=Viug Siddite Both Sides • Material Type:Smooth Star • Product Type: Exterior • Brand:Therma-Tru • Configuration (Units viewed from Exterior): Single Door w 2 Sidelites • Sidelite Vent: Fixed • Reeb Finish: No • Unit Construction: Continuous • Slab Width: 36" • Slab Height: 80" • Product Style: Craftsman • Glass Type: Clear • Glass Style:SDL • Glazing Type: Flush Glazed • Insulation: Low E • Grille Type: SDL Shaker Profile • Model:S4816-SDLFlLE • Sidelite Product Material:Smooth Star Fiberglass • Sidelite Material Type:Smooth Star • Sidelite Width: 10" • Sidelite Height: 80" • Sidelite Style: Full Lite • Sidelite Glazing Type: Flush Glazed • Sidelite Glass Type: Clear • Sidelite Glass Style: Clear • Sidelite Insulation: Insulated Glass • Sidelite Model:S2000SL • Frame Material: FrameSaver • Handing: Right Hand Inswing • Casing/Brickmould Pattern: None • Hinge Type: Radius x Square (Self Aligning) • Hinge Brand:Therma-Tru • Hinge Finish: Brushed Nickel • Jamb Depth:4 9/16" • Sill: Composite Adjustable • Sill Finish:Satin Nickel w Light Cap • Multi-Point Lock: None • Bore: Double Lock Bore 2-3/8" Backset • Strike Jamb Prep: No • Weatherstrip Type: Compression • Weatherstrip Color:White • Custom Height Option: No https://m2o.edgenet.comNiewProj ects/GetBasicQuoteFini shed?Proj ectId=2153349&ts=63... 2/14/2018 •m2o Quote Form Page 5 of 5 • Storm Door Adapter Kits:Yes • Kick Plate: None • Door Viewer: None • Sill Cover: No • Dentil Shelf: None • Rough Opening Width: 601/2" • Rough Opening Height: 82 1/2" • Total Unit Width(Includes Exterior Casing): 59 5/8" • Total Unit Height(Includes Exterior Casing): 82" Item Total: $ 1,731.38 Item Quantity Total: $ 1,731.38 Unit Summary H;de Item Description QuantityUnit Price Total Price 0094:Ext 36" S2059 S D 66E RHI 4 9�162 FFamegayeF ., 1 $ $m i,664.86 i,664.06- t 0003 Ext 36"x 80" 52000-3C-SDL RHI 4 9/16" FrameSaver 1 $ 814.00 $ 814.00 0004 Ext 10"/36"/10" x 80" 52000SL/54816-SDLFlLE/S2000SL 1 $ $ RHI 4 9/16" FrameSaver 1,731.38 1,731.38 ._.Tian M. ®S1,13TOTAL; $ 2,609 44 ACCEPTED BY: /�T�AXES ( %��): $ 0.00 L7 �; GILD TOTTAL:^$ 3,60944- Additional Information: I understand that this order will be placed according to these specifications and is non-refundable. All products are unfinished unless otherwise specified and should be finished as per the instructions provided by the manufacturer. Images on this quote should be considered a representation of the product and may vary with respect to color, actual finish options and decorative glass privacy ratings. Please verify with sales associate before purchasing. Unless otherwise noted, prices are subject to change without notice, and orders accepted subject to prices in effect at time of shipment. Prices in this catalog apply only to sizes and descriptions listed; any other specifications will be considered special and invoiced as such. https://m2o.edgenet.comNiewProjects/GetBasicQuoteFinished?Projectld=2153349&ts=63... 2/14/2018 MANUFACTURER PRODUCT QTY DIMENSIONS ROUGH MODEL MATWERIAL GLASS LOCATION OPENING NUMBER REEB-SMOOTH STAR DOOR 1 36"X80" 38.5"X82.5" S200D-3C-SDL FIBERGLASS INSULATED LOW E S.E.WALL,1ST FLOOR REEB-SMOOTH STAR DOOR 1 56"X80" 60.5"X82.5" 52000&52000SL FIBERGLASS INSULATED LOW E W.WALL,IST FLOOR ANDERSON WINDOW 12 37.625"X64.875" 38.125"X64.875" 400 SERIES,TW3052(AA) FIBREX LOW-E4 GLASS W,S.E.,&N.WALL,IST FLOOR ANDERSON WINDOW 129.625"X44.875" 30.125"X44.875" 400 SERIES,TW2436(AA) FIBREX LOW-E4 GLASS E WALL,1ST FLOOR ANDERSON WINDOW 1 48"X40.8.125" 48.5"X41.375" 400 SERIES,C235(LR) FIBREX LOW-E4 GLASS E WALL,IST FLOOR ANDERSON SLIDER 1 71.25"X79.5" 72"X80" 400 SERIES,FWG6068(SR) FIBREX LOW-E4 GLASS E WALL,1ST FLOOR ANDERSON WINDOW 1 75.375"X64.875" 75.875"X64.875" 400 SERIES,TW3052-2(AA) FIBREX LOW-E4 GLASS E WALL,IST FLOOR ANDERSON WINDOW 2 29.625"X44.875" 30.125"X44.875" 400 SERIES,TW2436(AA) FIBREX LOW-E4 GLASS S WALL,2ND FLOOR ANDERSON WINDOW 3 37.625"X56.875" 38.125"X56.875" 400 SERIES,TW3046(AA) FIBREX LOW-E4 GLASS S WALL,2ND FLOOR ANDERSON WINDOW 2 29.625"X48.875" 30.125"X48.875" 400 SERIES,TW24310(AA) FIBREX LOW-E4 GLASS E WALL,2ND FLOOR ANDERSON WINDOW 1 31.5"X48" 32"X48.5" 400 SERIES,CX14(L) FIBREX LOW-E4 GLASS N.WALL,2ND FLOOR "NU Vr---'A' ' spry U 'E� H-r- t N Aco i- '- MPA ar - 4 - . t de- r-',-, ;nd-1 tl,ona 0 4, ll.-ST, e. Hl - 40 se- -!e wen R -5, 77- te C F , =I A=k EX"TC, -E :N -S i A Mi B-L A -Do, an cer A n- --,S- T"O -2 p _ ; A iii _ ' Air Air Handlers ' I RH1T/RH2T Series The new degree of comfoft." (• Rheem High Efficiency Air Handler RH1T/RH2T Series 7" -R Constant Torque Motor(ECM) Efficiencies up to 16 SEER cPus _,° tutE• • RH1T/RH2T feature a Constant Torque motor(ECM)which • 11/2 ton[5.3 kW]through 5 ton[17.6 kW]models are between provides enhanced SEER performance with most Rheem out- 421/2 to 551/2 inches[1080 to 1410 mm]tall and 22 inches door units. [559 mm]deep. • Versatile 4-way convertible design for upflow,downflow, • All models meet or exceed 330 to 400 CFM[156 to 189 Vs] horizontal left and horizontal right applications. per ton at.3 inches[.7 kPa]of external static pressure. • Factory-installed indoor coil. • Enhanced airflow up to.7"external static pressure. • Sturdy cabinet construction with 1.0 inch[25.4 mm]of • Evaporator is constructed of aluminum fins bonded to inter- foil faced insulation for excellent sound and insulating nally grooved aluminum tubing. characteristics. • Field-installed auxiliary electric heater kits provide exact heat for indoor comfort. Kits include circuit breakers which meet U.L.and cUL requirements for service disconnect. INTEGRATED HOME COMFORT FORM NO.H11-553 REV.1 Air ITable of Contents RHiT/RH2T Series TABLE OF CONTENTS Engineering Features ......................................................................................3 Model Number Identification............................................................................4 DimensionalData ........................................................................................5-6 AirflowDirectional Data ..................................................................................7 Airflow Performance Data RH1T..................................................................8-12 ElectricalData RH1T................................................................................13-16 Airflow Performance Data RH2T................................................................17-20 Electrical Data RI-12T................................................................................21-22 ElectricalWiring............................................................................................23 Accessories............................................................................................................23 LimitedWarranty ..........................................................................................24 INTEGRATED . COMFORT Air Engineering Features 0 RHiT/RH2T Series Engineering Features RHiT/RH2T=Series • The most compact unit design available,all standard heat air • Coils are tested at the factory with an extensive refrigerant handler models only 421/2to 551/2 inches[1079 to 1409 mm]high. leak check. • Attractive pre-painted cabinet exterior. • Coils have copper sweat refrigerant connections. • Rugged wall steel cabinet construction,designed for added • Coils utilize chatleff metering device connections. strength and versatility. • Molded polymer corrosion resistant condensate drain pan is • 1.0"foil faced insulation mechanically retained in blower provided on all indoor coils. compartment for excellent thermal and sound performance. . Supply duct flanges provided as standard on air handler • Four leg blower motor mount. cabinet. • Blower housing with controls,motor and blower.Slide out • Provisions for field electrical,connections available from design for service and maintenance convenience. either side or top of the air handler cabinet. • Traditional open wire element design for heat applications. • Connection point for high voltage wiring is inside the air han- • Field convertible for vertical downflow, horizontal left hand or dler cabinet.Low voltage connection is made on the outside right hand air supply. of the air handler cabinet. • 3 combustible floor base accessories fit all model sizes when • Concentric knockouts are provided for power connection to required for downflow installations on combustible floors. cabinet.Installer may pull desired hole size up to 2 inches • Indoor coil design provides low air side pressure drop,high [51 mm]for 11/2 inch[38 mm]conduit. performance and extremely compact size. • Front refrigerant and drain connections. • Expansion valve on indoor cod provides for operation with air conditioning. [ ]Designates Metric Conversions • Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. INTEGRATED fE.� 'r• E d rY�:r HOME COMFORT Air IModel Number Identification RH1T/RH2T Series R H 1 T 24 17 S T A N A A *** Z-Option Code(see ADS-3803) Blank=None Minor Series A=First Voltage A=115/1/60 D=480V/3/60 J =208/240/1/60 Controls C=Communicating N=Non-Communicating Major Series A=First Metering Device T=TEV E=EEV P=Piston Coil Efficiency S=Standard M=Medium H=High Width 17=17.5"[431.8 mm](600-1200 CFM) 21=21"[533.4 mm](800-1600 CFM) 24=24.5"[609.6 mm](1400-1800 CFM) Nominal Capacity 24=18,000[5.27 kW]-24,000[7.03 kW]BTU/H 36=30,000[8.79 W+36,000[10.55 kW]BTU/H 48=42,000 112.31 kW]-48,000[14.06 kW]BTU/H 60=60,000[17.58 kW]BTU/H Motor Type T=Constant Torque(ECM) Stages of Air Flow 1 =Single 2 =Two Stage Product Category H=Air Handler Rheem [ ]Designates Metric Conversions Available Models at 115V A Voltage RH1T2417STANAA RH1T3617STANAA RH1T3621MTANAA RHIT4821STANAA RMT4824STANAA RMT6024STANM Available Models at 218V J Voltage RMT2417STANJA A--r`rl L RH1T3617STANJA RH1T3621MTANJA L RH1T4821STANJA RH1T4824STANJA RH1T6024STANJA RH2T2421MTANJA RH2T3621MTANJA RH2T4824MTANJA RH2T6024STANJA Available Models at D Voltage RMT6024STANDA 4 INTEGRATED • • •- Air Dimensional Data 0 I RHiT/RH2T Series Unit Dimensions ELECTRICAL CONNECTIONS SUPPLY AIR j NOTE'24"CLEARANCE REQUIRED IN FRONT OF MAY EXIT VOLTAGETOP REITHERNNECTI GIDE UNIT FOR FILTER AND COIL MAINTENANCE. HIGH VOLTAGE CONNECTION 4r 122 2 mml NOC t+fn'127 S mml,ln/y 150 mml 010.KNOCKOUTS. 10s/m' [262 mmJ W A LOW VOLTAGE CONNECTION 'Ir[159 mmJ AND Ile 1222 mm]KNOCKOUT Return Air Opening Dimensions Model Return Air Return Air Opening Cabinet Size Opening Width Depth/Length 0 a (inches) (Inches) 17 157/8 193/4 00 21 193/6 193/4 24 227/8 193/4 H AUXILIARY DRAIN CONNECTION , 'A'[1 !�'[191 mm]FEMALE PIPE THREAD(NPT) HORIZONTAL APPLICATION ONLY PRIMARY DRAIN CONNECTION 0 yr 119 mmJ FEMALE PIPE THREAD(NPT) AUXILIARY DRAIN ON ur(1911=1 FEMALE PIPE(THREAD(NPT) UPFLOW/DOWNFLOW APPLICATION ONLY 1 RET[495 mmJ � RETURN AIR OPENING 21 Ae LIQUID LINE CONNECTION 1551 mmJ COPPER(SWEAT) VAPOR LINE CONNECTION COPPER(SWEAT) UPFLOW UNIT SHOWN. UNIT MAY BE INSTALLED UPFLOW,DOWNFLOW, HORIZONTAL RIGHT OR LEFT AIR SUPPLY. 515h6" HORIZONTAL ADAPTER KIT 1151 IT11711 [105/mm] 31/16" j [76 mm] 13/16"[48 mm]IVa"[29 mm] 11/16" [27 mm] 13/6T) [35 mm] 213/16" VAPOR LINE [71 mm] 51/4" CONNECTION [133 mm] 53/8" [136 mm] AUXILIARY HORIZONTAL DRAIN CONNECTION UPFLOW UNIT SHOWN: O UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW,HORIZONTAL RIGHT OR LEFT AIR SUPPLY. o � [ ]Designates Metric Conversions PRIMARY DRAIN ( )Designates Unit with Double Coil Cabinet CONNECTION LIQUID LINE VERTICAL DRAIN PAN CONNECTION AUXILIARY UPFLOW/DOWNFLOW DRAIN CONNECTION COMFORTINTEGRATED HOME Air IDimensional Data RHiT/RH2T Series Unit Dimensions&Weights Refrigerant Connections Unit Unit Su I Air Flow Unit Weight/Shipping Weight Model Size Sweat(In.)[mm]III Width Unit Dssty CFM(Nom.)[L/s1 (Lbs.)[kgl Unit With RH1T Liquid Vapor "W"In.[mm] "H"In.[mml "A"In.[mm] Lo Hi Coil(Max.KW) 2417ST_ 3/e[9.53] _ 3/4[19.05] 171/2[445] 421/2[1080] 16 [406] 600[283] 800[378] 92/105[42/48] 3617ST 3/819.53] 3/4[19.05] 1712[445] 421/2[1080] 1 16 [406] 1000[472] 1200[566] 96/110[44/50] 3621 MT 3/e[9.53] _ 7/9[22.23] 21 [533] 501/2[1282] 191/2[495] 1000[472] 1200[566] 126/142[57/64] 48218T_ 3/6[9.53] 7/e[22.23] 21 [533] 501/2[1282] 191/2[495] 1400[661] 1600[755] 128/144[56/65] 4824ST 3/e[9.53] 7/9[22.23] 241/2[622] 501/2[1282] 23 [584] 1600[755] — 142/160[64/72] 6024ST 3/e[9.53] 7/e[22.23] 241/2[622] 551/2[1410] 23 [584] — 1800[850] 159/176[72/80] .Maximum dehumiddicahon airflow. Unit Dimensions&Weights Model Refrigerant Connections Unit Unit Su I Air Flow Unit Weight/Shipping Weight Size Sweat(In.)[mm]ID Width Height Dusty CFM(Nom.)[L/s1 (Lbs.)[kgl RH2T Liquid Vapor "W"In.[mm] "H"In.[mm] "A"In.[mm] Lo Hi Unit With Coil(Max.KW) 2421 MT 3/e[9.53] 3/4[19.05] 21 [533] 421/2[1080] 191/2[495] 525[248] 700[330] 111/126[50/57] 3621 MT 3/e[9.53] 7/e[22.23] 21 [533] 501/2[1282] 1912[495] 800[377] 1050[495] 129/145[59/66] 4824MT 3/e[9.53] 7/e[22.23] 2412[622] 551/2[1410] 23 [584] 1050[495] 1400[660] 128/146[58/66] 6024ST 3/e[9.53] 7/e[22.23] 241/2[622] 551/2[1410] 23 [584] 1200[566] 1600[755] 161/178[73/81] [ ]Designates Metric Conversions INTEGRATED • • •- Air Airflow Directional Data �i RH1T/RH2T Series Airflow Directional Data UPFLOWDOWNFLOW 00 0 ° o 0 o° • °O HORIZONTAL LEFT HORIZONTAL RIGHT HAND AIRFLOW HAND AIRFLOW . o 0 o o o0 0 °0 0 INTEGRATEDCOMFORT -99 Air Electrical Wiring 0 RHiT/RH2T Series Electrical Wiring Power Wiring Grounding • Field wiring must comply with the National Electrical Code •This product must be sufficiently grounded in accordance with (C.E.C.in Canada)and any applicable local ordinance. National Electrical Code(C.E.C.in Canada)and any applicable •Supply wiring must be 75°C minimum copper conductors only. local ordinance. •See electrical data for product Ampacity rating and Circuit •A grounding lug is provided. Protector requirement. Accessories •Combustible Floor Base RXHB- •Auxiliary Electric Heater Kits RXBH- Combustible Floor Heater Kits include circuit breakers which meet UL and cUL Model Cabinet Size Base Model Number requirements for service disconnect.See the Electric Heat 17 RXHB-17 Electrical Data in this specification sheet for specific Heater Kit 21 RXHB-21 Model numbers. 24 RXHB-24 . External Filter Base RXHF- •Jumper Bar Kit 3 Ckt.to 1 Ckt RXBJ-A31 is used to convert single phase multiple three circuit units to a single supply Model Cabinet Size Filter Size In.[mm] Part Number" A B circuit.Kit includes cover and screw for line side terminals. 21 20 x 20[508 x 508] RXHF-21 19.20 21.0 •Jumper Bar Kit 2 Ckt.to 1 Ckt.RXBJ-A21 is used to convert 24 25 x 20 1635 x 508] RXHF-24 22.70 25.5 single phase multiple two circuit units to a single supply circuit. *Accommodates 1"or 2"filter Kit includes cover and screw for line side terminals. •Note:No jumper bar kit is available to convert three phase •Horizontal Adapter Kit RXHH- multiple two circuit units to a single supply circuit. This horizontal adapter kit is used to convert Upflow/Downflow only models to horizontal flow.See the following table to order •Auxiliary Horizontal Overflow Pan Accessory RXBM- proper horizontal adapter kit. Nominal Cooling Auxiliary Horizontal Overflow Pan Coil Model Horizontal Adapter Kit Horizontal Adapter Kit Capacity-Tons Accessory Model Number Model Number(Single Qty.) Model Number(10-Pack Oty.) 11/2-3 RXBM-AC48 2414 RXHH-A01 RXHH-A01 x 10 31/2-5 RXBM-AC61 2417 RXHH-A02 RXHH-A02 x 10 3617/3621 RXHH-A03 RXHH-A03 x 10 • External Filter Rack RXHF-B17,B21,B24 3821/4821/4824 RXHH-A04 RXHH-A04 x 10 Model Cabinet Size Filter Size In.[mm] PartNumber` A B 6024 RXHH-A05 RXHH-A05 x 10 17 16 x 20[406 x 508] RXHF-B17 16.90 20.77 •External Filter Base RXHF- 21 20 x 20[508 x 5081 RXHF-B21 20.40 20.77 Model Cabinet Size Filter Size In.[mml Part Number` A J25.5 24 25 x 20[635 x 5081 RXHF-B24 25.00 21.04 17 16 x 20[406 x 508] RXHF-17 15.70 "'Accommodates 1"filter 21 20 x 20[508 x 5081 RXHF-21 19.20 24 25 x 20[635 x 508] RXHF-24 22.70 [ ]Designates Metric Conversions `Accommodates 1"or 2"filter RXHF- �„ (B) +3/50" / (191/7')[495 30 mm] RXHF-B [1524 mm] -3/50'[1 524 mmi (21-) �r A_3/25• -3/25.13 048 mm] 1533 mm] 11/2" ,.-' r� ��- 13.048 mm] FLANGE LENGTH , `*; ,_ ,r A (31/4")182 55 mm] B `,.,Y ', � (1918/25")[500 888 mmJ (OPENING) a COMFORTINTEGRATED HOME Limited Warranty —0 Air I RHiT/RH2T Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product Conditional Parts(Registration Required)..........Ten(10)Years which fails in normal use and service within the applicable *For complete details of the Limited and Conditional Warranties,including periods stated,in accordance with the terms of the limited applicable terms and conditions,contact your local contractor or the warranty. Manufacturer for a copy of the product warranty certificate. 24 INTEGRATED • COMFORT a Ali� ..-...' - ,MODEL 'NO,/ . MODE,LE .N RAl648AJ 1NB - MFD./FAB 05,'12018 D.E. .5ER I E 'W211811452 OUTDOOR USE/ UTILISATION 0 'EXfi 1EURE COMPRESSOR CODE / CODES ,DE ,COMPRESSEUR 9,064 'VOLTS X08/230` PHASE. . 1° . HERTZ 60 COMPRESSOR/ COMPRESSEUR R. L.A. 17.0/11.0 L.R.A. 123.9 ,E OUTDOOR .FAN, MOTORI MOT.EUR VENTI'L. `EXT. f.11L.A. . 3.5' l P. 1/3 MIN. SUPPLY CIRCUIT AMPACITY/ COURANT ADMISSABLE" VALIM. MIN. 25/25 A- MAX." FUSE 6R-'CKT4. BKR:" SIZU CAL. MAX. DE FUSIBLE/DISJ 40/40 A FUSE OR CKT, BRK SIZE/ MIN. •. " 30/30 ,° A 'CAL. MIN:, DE, FUSIBLE/DISJ' DESIGN PRESSURE HIGH/ 450 PSIG/3102 kPa PRESSION ,NOMI4ALE HAUTE . DESIaGN PRESSURE. LOW/,.,, :. 250 PSIGI1723 1pa, PRESSION NOMIRALE BASSE ° OUTDOOR UNITS FACTORY CHARGE/ 174 oz/4933g R410A CHARGE USINE D' UNITES 'EXTERIEUR 'l -SYSTEM 'CH'ARGE/ R410A CHARGE TOTALE DU SYSTEMS SEE INSTRUCTIONS INSIDE ACCESS PANEL VOIR •LES CHARGE INSTRUCTIONS A L'INTERIEUR DU PANNEAU D'ACCESIwo RNEEM SALES' 'COMPANY r, FORT SMITH, ARKANSAS ASSEMBLED IN *HACR TYPE,BREAKER FOR U.S.A./ MEXICO DISJONCTEU,R. DIFFERENTIEL IPX4 ZA :".e i`IIIIIIiiIiIIIIIIIi�lh41111-ilililllillllifllllll1111111IIIIL ." „' . �,,�2��2a�o-l� .: ,�i 1 T gr ' ' +t- MWE E N,. ;RA'1624AJi"NB AWE ; W MFQ.[FAR 04/2018 . _ r5 N-° :DE` SERI E. W161T834126_ OUTDOOR USE/, .w UTILISATION EN fXTRIEUR€ wC MPESSOR`-CQOE % CODES".DE ,COMPRESS:El1R , 906 ,"416L s ;Y: a'a - 3o ' PFlAS E: 1F N ERTZ 60 .41PRES'SOR; r C4MPR SSEUR7;� •Ri"L,A�S lo':3�1�::3 L:�R�.A. X1,6 IJTQ4OR F�YAN MOTOR/ F:L.A: ,'.r0:6` H..P." 1/6'' �',.�• ��10�':"�UR����ENTI''�=; :„EST - .^ �:� " � _ , . r � -^ _• 'C:I�RCUIT,AMPACITY/. :RAT ..AUI: . AB 14/14; A` k b COU. N' S-S L`E.';p ALIM.. MlK6 ;. FOSE` R=`CKT,: -BKR: ,`,SIZE , � "• :. AX20%20'. to +A ^ QE....EU'S,IRLEInISJ OR .CST,..^BRK•,.,SI Z;E/ !"! Ala:.:"C Ny M.,11E FUSIBLE/`R^I;SJ PRESS:UR'E`. IlGH/. :PSIG 3`102.:k FRES," 'ION°.,:N()MINALE "PRES.SIJRE`° L4W/ ;,.: 2 p;:'PS It/i`723`akh F. S��ON, �NQNII.NALE.' PRES z. •�}}}'���t ,; i ITS, FAOTOW',CHARGE/� g7 z/246.6g R41OA•, M{ A - ` TES:.EXTE. ,', R C. = 1SyGI N:E D ;,SNI;' a R.41�OA T;QTA :-SYSTxE� °yN`ARGE°I 'L7 `• m O "A SYSTEM ,E' -CHARDCESrS PANEL '�' . w:INST4 llC f I"(1NS IXd %1'DE AC DACCES r, •," CTIONS" L'INTERIEUR HARE JNS7RU �;... t ;bER, SAL "'COMPANYAssEata�EO', �:.. ;ARKANSAS, TK F{)RT.m,SMIT'H MEXICO,. . T . ,E BR`EA ER `E NFACR O ERENTIELr. In 92-2200=4 , aI O:NCT E R .aET F,, Illllll Illillllll!`lIII. CpNTAGT,ORs!".off. cyte•. GL pQLE, termi�a��d�ri _ SjN E �sts;at`ait RES ; - Y otent ::eN{pp�;A� ies`bo�' ` }' Volta98,tP EURS ur touter 014T , -- tensions 5-0s-o2 = d`avoir:.��e• cle d` et. , : 11 est Pible /,endant Ie GY Air IAir Conditioners RAI6 Series 11 'The new degree of Comfort., Rheem Classic® Series Air Conditioners } __ _ RA16 Series Efficiencies up to 16 SEER/13 EER Nominal Sizes 11/2 to 5 Ton [5.28 to 17.6 kW] Cooling Capacities 17.3 to 60.5 kBTU [5.7 to 17.7 MM g w"�. CUL us I. I r UMD 8 "Proper sizing and Installation of equipment is critical to achieve optimal performance.Spht system air conditioners and heat pumps must be matched with appropriate call components to meet Energy Star. Ask your Contractor for details or visit www.energystargov." • Composite base pan—dampens sound,captures louver • Diagnostic service window with two-fastener opening— panels,eliminates corrosion and reduces number of fasteners provides access to the high and low pressure. needed • External gauge port access—allows easy connection of • Powder coat paint system—for a long lasting professional finish 'low-loss"gauge ports • Scroll compressor—uses 70%fewer moving parts for higher • Single-row condenser coil—makes unit lighter and allows efficiency and increased reliability thorough coil cleaning to maintain"out of the box" • Modern cabinet aesthetics—increased curb appeal with visu- performance ally appealing design • 35%fewer cabinet fasteners and fastener-free base—allow • Curved louver panels—provide ultimate coil protection, for faster access to internal components and hassle-free enhance cabinet strength,and increased cabinet rigidity panel removal • Optimized fan orifice—optimizes airflow and reduces unit • Service trays—hold fasteners or caps during service calls sound • QR code—provides technical information on demand for • Rust resistant screws—confirmed through 1500-hour salt faster service calls spray testing • Fan motor harness with extra long wires allows unit top to be • PlusOneTM Expanded Valve Space—3"-4"-5"service valve removed without disconnecting fan wire. space—provides a minimum working area of 27-square inches for easier access • PlusOneTM Triple Service Access—15"wide,industry lead- ing corner service access—makes repairs easier and faster. The two fastener removable corner allows optimal access to internal unit components.Individual louver panels come out once fastener is removed,for faster coil cleaning and easier cabinet reassembly INTEGRATED HOME COMFORT FORM NO.All-222 REV.6 t ' Air Table of Contents �i RAI 6 Series TABLE OF CONTENTS StandardFeature......................................................................................................3 AvailableSKUs ........................................................................................................3 Features&Benefits ..............................................................................................4-5 Model Number Identification ................................................................................6-7 General Data/Electrical Data....................................................................................8 Accessories ............................................................................................................9 WeightedSound Power............................................................................................9 Thermostats..............................................................................................................9 UnitDimensions......................................................................................................10 Clearances..............................................................................................................11 WiringDiagrams ....................................................................................................12 ApplicationGuidelines............................................................................................12 Refrigerant Line Size Information......................................................................13-16 PerformanceData ............................................................................................17-64 GuideSpecifications ..............................................................................................65 LimitedWarranty....................................................................................................66 INTEGRATED . COMFORT Air Standard Feature/Available SKUs 'a RA16 Series Standard Feature Table STANDARD FEATURES Feature 18 24 30 36 42 48 60 R-41 Oa Refrigerant J J J J J J J Maximum SEER 16 16 16 16 16 16 16 Maximum EER 13 13 13 13 13 13 13 Scroll Compressor J ✓ J ✓ J J ✓ Field Installed Filter Drier J J J J J J ✓ Front Seating Service Valves J J J ✓ J J J Internal Pressure Relief Valve J J J J ✓ J J Internal Thermal Overload J J J J J J J Long Line capability ✓ J ✓ J ✓ J J Low Ambient capability with Kit ✓ ✓ J J J J J 3-4-5 Expanded Valve Space ✓ ✓ J ✓ J ✓ ✓ Composite Basepan J ✓ ✓ J J J J 2 Screw Control Box Access J J J ✓ J ✓ ✓ 15°Access to Internal Components J J J J J ✓ J Quick release louver panel design ✓ J J J ✓ J ✓ No fasteners to remove along bottom J ✓ J ✓ J J ✓ Optimized Venturi Airflow ✓ J J J J ✓ ✓ Single row condenser coil J J J J ✓ ✓ J Powder coated paint J J J ✓ ✓ ✓ J Rust resistant screws J J J ✓ ✓ J J OR code J J ✓ J J ✓ ✓ External gauge ports J J J ✓ J J J Service trays J J J J J J J J=Standard Available SKUs Available Models Description RA1618AJl NA Classic®Series 1 1/2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1624AJl NA Classic®Series 2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1630AJl NA Classic®Series 21/2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1636AJI NA Classic®Series 3 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1636BJ1 NA(Canada) Classic®Series 3 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1642AJl NA Classic®Series 31/2 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1648AJl NA Classic®Series 4 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1660AJl NA Classic®Series 5 ton 16 SEER Single-Stage Air Conditioner-208/230/1/60 RA1618AJl NB Classic®Series 1 1/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1624AJ1 NB Classic®Series 2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1630AJl NB Classic®Series 21/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1636AJl NB Classic®Series 3 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA163613J1 NB(Canada) Classic®Series 3 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1642AJl NB Classic®Series 31/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1648AJ1 NB Classic®Series 4 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1660AJl NB Classic®Series 5 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/1/60 RA1636ACl NB Classic®Series 3 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/3/60 RA1636BC1 NB(Canada) Classic®Series 3 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/3/60 RA1642ACl NB Classic®Series 31/2 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/3/60 RA1648ACl NB Classic®Series 4 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/3/60 RA1660AC1 NB Classic°'Series 5 ton 16 SEER Single-Stage Air Conditioner w/High/Low Pressure-208/230/3/60 INTEGRATED HOME COMFORT Air Features&Benefits 0 RA16 Series Introduction to RA16 Air Conditioner The RA16 is our 16 SEER air conditioner and is part of the Rheem air conditioner product line that extends from 13 to 20 - SEER.This highly featured and reliable air conditioner is vY 12 designed for years of reliable,efficient operation when matched with Rheem indoor aluminum evaporator coils and furnaces or air handier units with aluminum evaporators. a Our unique composite base(M)reduces sound emission,elimi- nates rattles,significantly reduces fasteners,eliminates corro- If in the rare event,greater access is needed to internal compo- sion and has integrated brass compressor attachment inserts nents,such as the compressor,the entire corner of the unit can UP.Furthermore it has incorporated into the design,water be removed along with the top cover assembly to have unprece- management features,means for hand placement(0)for unit dented access to interior of the unit(R).Extra wire length is maneuvering,screw trays(®)and inserts for lifting off unit incorporated into each outdoor fan and compressor so top pad. cover and control panel can be positioned next to the unit.With minimal effort the plug can be removed from the compressor 0 and the outdoor fan wires can be removed from the capacitor to allow even more uncluttered access to the interior of the unit(EN). - T. Outdoor coil heights range from as short as 27"to 48",aiding access to the compressor.Disassembly to this degree and com- plete reassembly only takes a first time service technician less a - z -- = than 10 minutes.(15) _. 18' Service Valves(©)are rigidly mounted in the composite base with 3"between suction and discharge valves,4"clearance below service valves and a minimum of 5"above the service valves,creating industry leading installation ease.The minimum 27 square-inches around the service valves allows ample room to remove service valve Schrader prior to brazing, lent of clear- -• � _..__" " ' "" ance for easy brazing of the suction and discharge lines to ser- vice valve outlets,easy access and hookup of low loss refriger- All units utilize strong formed louver panels which provide indus- ant gauges(❑7 ),and access to the service valve caps for try leading coil protection.Louver removal for coil cleaning is opening.For applications with long-line lengths up to 250 feet accomplished by removing one screw and lifting the panel out of total equivalent length,up to 200 feet condenser above evapora- the composite base pan.(,7)All RA16 units utilize single row tor,or up to 80 feet evaporator above condenser,the long-line coils(,6)making cleaning easy and complete,restoring the instructions in the installation manual should be followed. performance of the air conditioner back to out of the box perfor- mance levels year after year. 10 Controls are accessed from the corner of the unit by removing only two fasteners from the control access cover,revealing the The outdoor fan motor has sleeve bearings and is inherently industry's largest 15"wide and 14"tall control area(®).With all protected.The motor is totally enclosed for maximum protection this room in the control area the high voltage electrical whip( s❑) from weather,dust and corrosion.Access to the outdoor fan is can easily be inserted through the right size opening in the bot- made by removing four fasteners from the fan grille.The outdoor tom of the control area.Routing it leads directly to contractor fan can be removed from the fan grille by removing 4 fasteners lugs for connection.The low voltage control wires(,o)are easily in the rare case outdoor fan motor fails. connected to units low voltage wiring.If contactor or capacitor (11)needs to be replaced there is more than adequate space to Each cabinet has optimized composite(f9)fan orifice assuring make the repair.Furthermore,if high pressure and low pressure efficient and quiet airflow. model was not purchased but is desired to be installed in the field,the service window(M)'can can be removed by removing two screws,to access the high and low side Schrader fittings for easy field installation.The entire corner can be removed providing ultimate access to install the high and low pressure switch.(1a) Air Features&Benefits �i RA16 Series The entire cabinet has powder post paint(FE-61)achieving 1000 Optional Accessories hour salt spray rating,allowing the cabinet to retain its aesthetics (Refer to accessory chart for model#) throughout its life. Compressor Crankcase Heater za Protects against refrigerant migration that can occur during low 20 ambient operation Compressor Sound Cover ss • Reinforced vinyl compressor cover containing a 11/2 inch thick batt of fiberglass insulation 21 •Open edges are sealed with a one-inch wide hook and loop fastening tape Compressor Hard Start Kit Scroll compressors with standard internal pressure relief and •Single-phase units are equipped with a PSC compressor internal thermal overload are used on all capacities assuring motor,this type of motor normally does not need a potential longevity of high efficient and quiet operation for the life of the relay and start capacitor product. •Kit may be required to increase the compressor starting Each unit is shipped with filter drier for field installation and will torque,in conditions such as low voltage trap any moisture or dirt that could contaminate the refrigerant Low Ambient Kit 22 system. •Air conditioners operate satisfactorily in the cooling mode down to 55°F outdoor air temperature without any additional 2s controls •This Kit can be added in the field enabling unit to operate properly down to 0°in the cooling mode 4 •Crankcase heater and freezestat should be installed on com- pressors equipped with a low ambient kit 3"/6"/12" All cabinets have industry leading structural strength due to the •Gray high density polyethylene feet are available to raise unit composite base pan(z1),interlocking corner post ffi),formed off of mounting surface away from moisture curved louver panels(2a)and drawn top cover(2a)making it Low Pressure the most durable cabinet on the market today. •Can be added in field enabling the unit to shut off compressor Each RA16 capacity has undergone rigorous psychometric test- on loss of charge ing to assure performance ratings of capacity,SEER NOTE:Unit can be purchased with high and low pressure and EER per AHRI Standard 210/240 rating condi- c 4� us installed at factory.(Refer to SKU list) tions.Also each unit bears the UL mark and each unit us= is certified to UL 1995 safety standards. High Pressure •Can be added in field enabling unit to shut off compressor if Each unit has undergone specific strain and modal testing to unit loses outdoor fan operation. assure tubing(29)is outside the units natural frequency and that the suction and discharge lines connected to the compressor NOTE:Unit can be purchased with high and low pressure withstand any starting,steady state operation or shut down installed at factory.(Refer to SKU list) forces imposed by the compressor. Decorative Top All units have been sound tested in sound chamber to AHRI 270 •Can be installed on fan grille rating conditions,and A-weighted Sound Power Level tables produced,assuring units have acceptable noise qualities(see page 9).Each unit has been ran in cooling operation at 95°F and 82°F and sound ratings for the RA16 range from as low as 70.7 dBA to 76.6 dBA. All units have been ship tested to assure units meet stringent '.over the road"shipping conditions. As manufactured all units in the RA16 family have cooling capa- bility to 55°F.Addition of low ambient control will allow the unit to operate down to 0°F.Factory testing is performed on each unit.All component parts meet well defined specification and continually go through receiving inspections.Each component installed on a unit is scanned,assuring correct component uti- lization for a given unit capacity and voltage.All condenser coils are leak tested with pressurization test to 550#'s and once installed and assembled,each units'complete refrigerant system is helium leak tested.All units are fully charged from the factory for up to 15 feet of piping.All units are factory run tested. The RA16 has a 10-year conditional compressor and parts war- ranty(registration required). COMFORTINTEGRATED HOME Air Conditioners* JL6 R A 16 24 A J 1 N A Brand Product SEER Capacity Major Series* Voltage Type Controls Minor Series** Option a a Category BTU/HR Code y Rheem A-Air Conditioners 13-13 SEER 18-18,000 [5.28 kW] A-1 st Design J-1 ph,208-230/60 1 -Single-stage C-Communicating A-1st Design N/A 3 Cr 14-14 SEER 24-24,000 [7.03 kW] B-2nd Design C-3ph,208-230/60 2-Two-stage N-Non-Communicating y 16-16 SEER 30-30,000 [8.79 kW] V-InverterCD 17-17 SEER 36-36,000[10.55 kW] 20-20 SEER 42-42,000[12.31 kW] 9 48-48,000[14.07 kW] ° 60-60,000[17.58 kW] *See page 3 for available SKU's. PumpsHeat 1 ■• R P 14 24 A J 1 N A ' Brand Product SEER Capacity Major Series* Voltage Type Controls Minor Series** Option Category BTU/HR Code Rheem P-Heat Pump 13-13 SEER 18-18,000 [5.28 kW] A-1 st Design J-1 ph,208-230/60 1-Single-stage C-Communicating A-1 st Design N/A 14-14 SEER 24-24,000 [7.03 kW] C-3ph,208-230/60 2-Two-stage N-Non-Communicating 15-15 SEER 30-30,000 [8.79 kW] D-3ph,460/60 V-Inverter 17-17 SEER 36-36,000[10.55 kW] P-Piston 20-20 SEER 42-42,000[12.31 kW] • 48-48,000[14.07 kW] 60-60,000[17.58 kW] CoilsFurnace 1 R' R C F 24 17 S T A M C A Brand Product Type Capacity Width Efficiency Metering Major Orientation Casing Minor Series`* Option Category BTU/HR Device Series* Code Rheem C-Evap Coil F-Furn Coil 24-24,000 [7.03 kW] 14-14° S-Standard Eff. T-TXV A-1st Design M-Multipoise C-Cased A-1st Design N/A H-Air-Handler 36-36,000[10.55 kW] 17-17.5° M-Mid Eff. E-EEV V-Vertical only/ U-Uncased Coil 48-48,000[14.07 kW] 21-21° H-High Eff. P-Piston convertible 60-60,000[17.58 kW] 24-24.5° H-Ded. Horizontal only -Model number ID's are for reference only.See available SKU page of applicable spec sheet for table of available SKU's for a specific model. [ ]Designates Metric Conversions 90%+ ARE Gas Furnaces 1 .. R 96 V A 70 2 3 17 M S A Brand Series Molar Major Rev Input Stages Air Flow Cabinet Configuration Nox Minor Rev BTU/HR Width Rheem 90-90 AFUE V-Variable speed A-1 st Design 040- 42,000[12.31 kW] 1 -Single-stage 3-up to 3 ton 14-14" M-Multi X-Low Nox A-1 st Design 92-92 AFUE T-Constant 060- 56,000[16.41 kW] 2 -Two-stage 5-3 1/2 up to 5 ton 17-17.5" S-Standard 95-95 AFUE Torque 070- 70,000[20.51 kW] M-Modulating 21-21" 96-96 AFUE (X-13) 085- 84,000[24.62 kW] 24-24.5° 97-97 AFUE P-PSC 100- 98,000[28.72 kW] 115-112,000[32.82 kW] 80% AFUE Gas Furnaces (For .. R SO 2 V A 075 3 17 M S A Brand Series Stages Motor Major Rev Input Air Flow Cabinet Configuration Nox Minor Rev BTU/HR Width Rheem 80-80+AFUE 1 -Single-stage V-Variable speed A-1st Design 050- 50,000[15 kW] 3-up to 3 ton 14-14" M-Multi X-Low Nox A-1st Design 2 -Two-stage T-Constant Torque(X-13) 075- 75,000[22 kW] 4-21/2 to 4 ton 17-17.5" D -Down S-Standard P-PSC premium 100-100,000[29 kW] 5-31/2 up to 5 ton 21-21" Z -Down& S-PSC standard 125-125,000[37 kW] 24-24.5" zero clearance 150-150,000[44 kW] down flow HandlersAir 1 '' R H 1 T 36 17 S T A N A A 000 Brand Product Stages of Motor Type Capacity Width Coil Size Metering Major Controls Voltage Minor Factory Heat Option Category Airflow BTU/HR Device Series* Series'* Cap Code • Rheem H-Air 1-Single-Stage V-Variable 24-24,000 [7.03 kW] 14-14" S-Standard T-TEV A-1st Design C-Communicating A-1 ph,115/60 A-1st Design 00-no *TBD Handler 2-Two-Stage Speed 36-36,000[10.55 kW] 17-17.5" Eff. E-EEV N-Non-comm J-1 ph,208-240/60 factory heat M-Modulating T-Constant 48-48,000[14.07 kW] 21-21" M-Mid Eff. P-Piston D-3ph,480/60 with option Torque 60-60,000[17.58 kW] 24-24.5" H-High Eff. code P-PSC **Model number ID's are for reference only.See available SKU page of applicable spec sheet for table of available SKU's for a specific model. [ ]Designates Metric Conversions J L6 D D o y a rn m y Z m c m 3 H Cr N a CD m 0 Air I General Data/Electrical Data 'a RAI 6 Series Physical Data PHYSICAL DATA Model No. RA1618A RA1624A RA1630A RA1636A RA1636B RA1642A RA1648A RA1660A Nominal Tonnage 1.5 2.0 2.5 3.0 3.0 3.5 4.0 5.0 Valve Connections Liquid Line O.D.-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Suction Line O.D.-in. 3/4 3/4 3/4 3/4 3/4 7/8 7/8 7/8 Refrigerant(R41 OA)furnished oz.s 82 87 113 108 108 150 174 201 Compressor Type Scroll Outdoor Coil Net face area-Outer Coll 12.1 14.8 16.2 18.8 17.29 24.2 28.3 32.3 Net face area-Inner Coil - - - - - - - - Tube diameter-in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Number of rows 1 1 1 1 1 1 1 1 Fins per inch 22 22 22 22 22 22 22 22 Outdoor Fan Diameter-in. 20 24 26 26 24 26 26 26 Number of blades 3 2 3 3 3 3 3 3 Motor hp 1/8 1/6 1/5 1/3 1/6 1/3 1/3 1/3 CFM 2405 2850 3915 4340 3300 4450 4660 4775 RPM 1095 851 710 819 825 829 828 795 watts 155 147 102 131 1 167 193 198 239 Shipping weight-lbs. 147 149 159 177 199 212 232 247 Operating weight-lbs. 140 142 152 170 192 205 225 240 Electrical Data Line Voltage Data(Volts-Phase-Hz) 208/230.1-60 208/230.1-60 208/230-1-50 208/230-1-60 208/230-1-60 208/230-1-60 208/230.1-60 208/230-1-60 Maximum overcurrent protection(amps)2 20 20 30 35 1 35 40 1 40 1 50 Minimum circuit ampacity3 12 14 18 23 23 25 1 25 34 Compressor Rated load amps 1 9 10.3 12.8 1 15.4 15.4 1 16.7 17 23.7 Locked rotor amps 47.5 61.6 67.3 83.9 83.9 109 123.9 152.5 Condenser Fan Motor Full load amps 0.7 0.6 2.8 3.5 1.5 3.5 3.5 3.5 Locked rotor amps 1.3 1.5 2.3 - .8 - 2.3 - Line Voltage Data(Volts-Phase-Hz) - - - 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 208/230-3-60 Maximum overcurrent protection(amps)2 - - - 25 20 25 30 35 Minimum circuit ampacity3 - - - 17 14 1 18 1 21 24 Compressor Rated load amps - - - 10.4 10.4 11.2 13.6 15.9 Locked rotor amps - - - 73 73 88 83.1 110 Condenser Fan Motor Full load amps - - - 35 .8 3.5 3.5 3.5 Locked rotor amps - - - - 1.5 - 2.3 - 'Refrigerant charge sufficient for 15 ft.length of refrigerant lines.For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 3Refer to National Electrical Code manual to determine wire,fuse and disconnect size requirements. COMFORT8 INTEGRATED HOME Air Accessories/Weighted Sound Powerffhermostats D RA16 Series Accessories Model No. RA1618 RA1624 RA1630 RA1636 RA1642 RA1648 RA1660 Compressor crankcase heater' 44-17402-44 44-17402-44 44-17402-44 44-17402-44 44-17402-45 44-17402-45 44-17402-45 Low ambient control RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 RXAD-A08 Freeze Stat 50313 50313 50313 50313 50313 50313 50313 Compressor sound cover 68-23427-26 68-23427-26 68-23427-26 68-23427-26 68-23427-25 68-23427-25 68-23427-25 Compressor hard start kit SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 SK-A1 Low pressure control RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 RXAC-A07 High pressure control RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 RXAB-A07 Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC (24 VAC,50/60 Hz) Solenoid Cod 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V 61-AMG24V Liquid Line Solenoid Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD3T3TVLC 200RD3T3TVLC (120/240 VAC,50/60 Hz) Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V Classic Top Cap w/Label 1 91-101123-21 1 91-101123-21 1 91-101123-21 91-101123.21 91-101123-21 91-101123-21 1 91-101123-21 'Crankcase Heater recommended with Low Ambient Kit. Weighted Sound Power Level (dBA) Unit Size-Voltage,Series Standard TYPICAL OCTAVE BAND SPECTRUM(dBA without tone adjustment) Rating(dBA) 125 250 500 1000 2000 4000 8000 RA1618A 76.6 53.4 60 65.7 66.3 64.2 58.8 52.6 RA1624A 75.5 49.9 58.4 61.4 64.1 61.6 57.3 50.8 RA1630A 74.3 48.4 57.4 62.6 64.5 61.5 56.5 51.5 RA1636A 76.4 54.5 62.7 67.1 66.5 62.7 58.5 54.3 RA1636B 75 56.1 58.7 63.1 66.1 62.3 59 55.7 RA1642A 70.7 47.5 51 60.2 60.7 59.7 53.6 50.4 RA1648A 74.3 51.2 56.1 64.5 65.6 60.7 56.6 52.6 RA1660A 74.6 50.1 55.1 65.6 64.8 63.2 57.4 56.4 NOTE.Tested in accordance with AHRI Standard 270-08(not listed in AHRQ COMFORTINTEGRATED HOME Air Unit Dimensions 0 RA16 Series Unit Dimensions OPERATING SHIPPING MODEL H(Height) L(Length) W(Width) H(Height) L(Length) W(Width) N0. INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm RAI 618A 27 685 29.75 755 29.75 755 27.375 695 32.25 819 32.25 819 RAI 624A 27 685 33.75 857 33.75 857 27.375 695 36.25 921 36.25 921 RAI 630A 27 685 35.75 908 35.75 908 27.375 695 38.25 972 38.25 972 RA1636A 31 787 3575 908 35.75 908 31.375 797 38.25 972 38.25 972 RAI 636B 31 787 33.75 857 33.75 857 31.375 797 36.25 921 36.25 921 RAI 642A 39 990 35.75 908 35.75 908 39.375 1000 3825 972 38.25 972 RAI 648A 45 1143 35.75 908 35.75 908 45.375 1153 38.25 972 38.25 972 RAI 660A 51 1295 35.75 908 35.75 908 51.375 1305 38.25 972 38.25 972 ALLOW 60"[1524 mm] OF CLEARANCE A 1 W D 1 S C H A R G E • H � SERVICE PANELS/ INLET CONNECTIONS/HIGH&LOW VOLTAGE ACCESS ALLOW 24"[610 mm]OF CLEARANCE AIR INLET LOUVERS ALLOW 6"[152 mm]MIN.OF CLEARANCE ALL SIDES 12"[305 mm]RECOMMENDED [ ]Designates Metric Conversions ST-A1226-02-00 10 INTEGRATED • • .- CLEARANCES WALL 'WALL 6" 152.4 24" (609.6) Service 12" 12" " 24 (609.6)) (304.8) (304.8) Service 6" (152.4) 6" (152.4) 12" (304.8) WALL • 24„ 24„ 24„ (609.6) (609.6) (609.6) Service Service Service 18" 24" 24" (457.2) (609.6) (609.6) 24"recommended 24" recommended 6" minimum 6"minimum dib NOTE: NUMBERS IN ()= mm n IMPORTANT When installing multiple units in an alcove,roof well or partially enclosed area,ensure there is adequate venlillation to prevent re-arculation of discharge air. 9 n D m rn °1 ST-A1225-01-00 y @ CD o m m N N a —on Air Wiring Diagram/Application Guidelines RAI 6 Series Control Wiring FIGURE 2 'IF MAXIMUM OUTLET TEMPERATURE RISE IS DESIRED,IT IS RECOMMENDED THAT CONTROL WIRING FOR GAS OR OIL FURNACE W1(W/BK)AND W2(WBL)BE JUMPERED TOGETHER. TYPICAL THERMOSTAT TYPICAL THERMOSTAT FOR TYPICAL GAS OR OIL HEAT SUBBASE FOR TYPICAL ELECTRIC HEAT SUBBASE Oy © OO ® Y G R BR-BROWN WIRE YL-YELLOW WIRE, BR-BROWN WIRE X-WIRE CONNECTION R-RED WIRE YL-YELLOW WIRE WBK-WHITE WIRE WITH BLACK STRIPE GBK-GREEN WIRE WITH BLACK STRIPE PU-PURPLE WIRE(NOT USED) X-WIRE CONNECTION TYPICAL GAS OR TYPICAL ELECTRIC HEAT OIL FURNACE LOW VOLTAGE JUNCTION BOX • X W/BL R TYPICAL CONDENSING R TYPICAL CONDENSING UNIT UNIT W/BK G/BK YL G YL YL _ Y Bfl � BR BR PU Application Guidelines 1. Intended for outdoor installation with free air inlet and outlet.Outdoor fan external static pressure available is less than 0.01 -in.wc. 2.Minimum outdoor operation air temperature for cooling mode without low-ambient operation accessory is 55°F(12.8°C). 3. Maximum outdoor operating air temperature is 125T(51.7°C). 4.For reliable operation,unit should be level in all horizontal planes. 5.Use only copper wire for electric connections at unit.Aluminum and clad aluminum are not acceptable for the type of connector provided. 6.Do not apply capillary tube indoor coils to these units. 7.Factory—supplied filter drier must be installed. INTEGRATED12 HOME COMFORT