Loading...
HomeMy WebLinkAbout42687-Z �� SUFfOt,��oG� Town of Southold 1/18/2019 P.O.Box 1179 O - �' 53095 Main Rd Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 40180 Date: 1/18/2019 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 15919 Route 25, East Marion SCTM#: 473889 Sec/Block/Lot: 23.-1-8.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated 5/10/2018 pursuant to which Building Permit No. 42687 dated 5/16/2018 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ROOF MOUNTED SOLAR PANELS ON AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Franco,Edmond of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 42687 01-14-2019 PLUMBERS CERTIFICATION DATED Authorized Signature o��oFFn��-coTOWN OF SOUTHOLD Gym BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy • o� SOUTHOLD, NY 'jlpl � ,ta BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 42687 Date: 5/16/2018 Permission is hereby granted to: Franco, Edmond 20 E 9th St Apt 11B New York, NY 10003 To: install roof-mounted solar panels on existing single-family dwelling as applied for. At premises located at: 15919 Route 25, East Marion SCTM # 473889 Sec/Block/Lot#23.-1-8.1 Pursuant to application dated 5/10/2018 and approved by the Building Inspector. To expire on 11/15/2019. Fees: SOLAR PANELS $50.00 ELECTRIC $100.00 CO -ALTERATION TO DWELLING $50.00 Total: $200.00 (A� Buildin spector Form No.6 TOWN OF SOUTHOLD. BUILDING DEPARTMENT 'T'OWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new, use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2110 of 1% lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance-from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957) non-conforming uses,or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building.and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00,Alterations to dwelling$50.00, Swimming pool $50.00,Accessory building$50.00, Additions to accessory building$50.00,Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3_ Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy -Residential $15.00,Commercial $15.00 Date. 5/7/18 New Construction: Old or Pre-existing Building: (check one) Location of Property: 15919 Main Road East Marion House No. Street Hamlet Owner or Owners of Property: Edmond Franco Suffolk County Tax Map No 1000, Section 23 Block 1 Lot 8,1 Subdivision Filed Map. Lot: Permit No. �t2_ Date of Permit. Applicant: GreenLogic LLC Health Dept.Approval: Underwriters Approval: Planning Board Approval: ora Certificate Tem Request for: Temporary fico Final Certificate: (check one) Fee Submitted: $ 50.00 A licant Signature ®F soUr�® Town Hall Annex Telephone(631)765-1802 54375 Main Road e� Fax(631)765-9502 P.O.Box 1179 G Q Southold,NY 11971-0959 •®lye �® roper.richert(c)-town.southold.ny.us BUELDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Edmond Franco Address: 15919 Route 25 city:East Marion st: New York zip: 11939 Building Permit#: 42687 Section- 23 Block: 1 Lot: 8.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Green Logic License No: 43858-ME SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixture Time Clocks Disconnect Switches Twist Lock Exit Fixtures �] TVSS Other Equipment: 19.440 KW Roof Mounted Photovoltaic System to Include: 54- Sun Power 360 Pane with Micro Inverters, AC Disconnect. Notes: Inspector Signature: Date: January 14, 2019 0-Cert Electrical Compliance Form.xis Pacifico Engineering PC i _ Engineering Consulting 700 Lakeland Ave, Suite 2B Ph,631-988-0000 Bohemia, NY 11716 t{ G c solar@pacificoengineering.com KW December 13,2018 Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject. Solar Energy Installation for Edmond Franco 15919 Main Road East Marian, NY 11939 1 have reviewed the solar energy system installation at the subject address on December 13, 2018.The units have been installed in accordance with the manufacturer's installation instructions and the approved construction drawing. I have determined that the installation meets the requirements of the 2017 NYS Residential Code(2015 International Residential Code -2nd Printing modified by the NYS Building Standards and Codes 2017 Uniform Code Supplement), and ASCE7-10. To my best belief and knowledge,the work in this document is accurate, conforms with the governing codes applicable at the time of submission, conforms with reasonable standards of practice,with the view to the safeguarding of life, health, property and public welfare. Regards, Ralph Pacifico, PE Professional Engineer FD L-1- -- t1--:z �,�,.. . r—•A1 JAN 9 2019 AJ � OF N��/� _SID r/ 1tAA 1 v QN PAC��i 0 ir W W Nt� 06618 Fid v OFESSIONP Ralph P gm,eer NY 066162/Ni 24GE04744306 SOUIyO� TOWN OF SOUTHOLD BUILDING DEPT. cou765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. Z/ [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) J ] ELECTRICAL (FINAL) [ ] CODE VIOLATION [ ] CAULKING REMARKS: DATE l� INSPECTOR ' FIELD INSPECTION REPORT DATE COMMENTS FOUNDATION(1ST) H ------------------------------------ 'FOUNDATION (2ND) �J u O ROUGH FRAMING& stn PLUMBING H 1 INSULATION PER N.Y: S y STATE ENERGY CODE b FINAL ADDITIONAL COMMENTS Z\ Zoo l � 0 Ih t l L 9\; ' l 0 z d b H TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631)765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. q:2au Ti Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined ,201— Storm-Water Assessment Form Contact: Approved (5 JP 20 Mail to: GreenLogic LLC Disapproved a/c 97 North Sea Road,Southampton,NY 11968 Phone: 631-771-5152 Expiration ,20 B ild ector PLICATION FOR BUILDING PERMIT Date May 7 ,20 18 MAY 1 0 2018 INSTRUCTIONS a.ThisealicatiMoeicompletely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,a .Fee according to schedule. b.M0f lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations,for the construction of buildings, additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances, building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. GreenLogic LLC (Signature of applicant or name,if a corporation) 97 North Sea Rd, Suite 3, Southampton, NY 11968 (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Contractor Name of owner of premises Edmond Franco (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. 40227-H Plumbers License No. N/A Electricians License No. 43858-ME Other Trade's License No. N/A 1. Location of land on which proposed work will be done: 15919 Main Road East Marion House Number Street Hamlet County Tax Map No. 1000 Section 2 3 Block 1 Lot 8.1 Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy Single family dwelling b. Intended use and occupancy Single family dwelling 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work Roof mounted solar electric system (Description) 4. Estimated Cost $75,388 Fee $ (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8.' Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear. Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO_X 13. Will lot be re-graded?YES NO X Will excess fill be removed from premises?YES NO 15919 Main Rd 14.Names of Owner of premises Edmond Franco Address East Marion,NY Phone No. Name of ArchitectPacifico Engineering PC Address 700 Lakeland Av,Bohemia Phone No 631-988-0000 Name of Contractor GreenLogic LLC Address 97 North Sea Road Phone No. 631-771-5152 Southampton, NY 11968 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO X * IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF Suffolk ) Nesim Albukrek being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the Contractor (Contractor,Agent, Corporate Officer, etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this 1�— day of Mc1 L4 20 1 Nota PublicId i nature of Applicant BARBARA A.CASCIOTTA g pp Notary NobPulic,State of New 0l1-CA4894969 Y olk Qualified In Suffolk Court Commission Expires May 11, 019 FQ Scott A. Russell °sUF ' � ST01KMWATIER. SUPERVISOR MANAGEMENT u^ m SOUTHOLD TOWN HALL-P.O.Box 1179 �. 53095 Main Road-SOUTHOLD,NEW YORK 11971 Town of Southold CHAPTER 236 - STORMWATER MANAGEMENT WORK SHEET ( TO BE COMPLETED BY THE APPLICANT ) _ DO.T� THIS 13:ERR0JEC.F 11NI L'OiLV E A 'Y OF THE F0:LiL0'k'1\T11N'G: `I j :CHECK ALL THAT %PPLYI Ij Yea No t l €' ❑ x❑ A. Clearing, grubbing, grading or stripping of land which affects more than 5,000 square feet of ground surface. il [:]El B. Excavation or Filling involving more than 200 cubic yards of material I� within any parcel or any contiguous area. ❑Q C. Site preparation on slopes which exceed 10 feet vertical rise to 100 feet of horizontal distance. I 41' ❑� D. Site preparation within 100 feet of wetlands, beach, bluff or coasta lil erosion hazard area. irk ❑ x� E. Site preparation within the one-hundred-year f loodplain as depicted ?� on FIRM Map of any watercourse. ❑Q F. Installation of new or resurfaced impervious surfaces of 1,000 square 1!I feet or more, unless prior approval of a Stormwater Management I� Control Plan was received by the Town and the proposal includes ; t, in-kind replacement of impervious surfaces. !! If you answered NO to all of the questions above, STOP! Complete the Applicant section below with your Name, Signature, Contact Information,Date & County Tax Map Number'. Chapter 236 does not apply to your project. If you answered YES to one or more of the above, please submit Two copies of a Stormwater Management Control Plan and a completed Check List Form to the Building Department with your Building Permit Application. S.C.T.Vt. I, ": 1000 Date , APPLICANT. fl'wperty OWN ner,De* ve jgn hofe�> nal.Agmt,Conhactor,Other; U[>tr(ct NAME- GreenLoq,� LLC (Nesim Albukrekl 23 1 8.1 5/7/18 Section Block Lot FOR BU11.T)li IQ DEPARTMENT ENT tisl:oi\'I.4 Contact Information '931-771-5152 o s Rei sewed By 6- I!, — — — — Date: j;' Property Address/ Local ton cif'Construes ton work: I i' — - — — — — — — — — — — — — — — � Approved for proce�,sutg Building Permit. 3 15919 Main Road 1', 4, Storm��ater\lanagenient Control Plan Not Reginrecl. ,. - - - - - - - - - - - - - - - - - l� €; East Marion, NY 11939 "' a Storrmratei-.viaiiagcmeiit Control Plan is Required. �I tFon ai d to Engineering Depai tment foi Revie\N,.) I. FORNI T"M SMCP-TOS MAY 2014 FOt - � BUILDING DEPARTMENT-Electrical Inspector TOWN OF SOUTHOLD Town Hall Annex - 54375 Main Road - PO Box 1179 Southold, New York 11971-0959 Telephone (631) 765-1802 - FAX (631) 765-9502 roger.richertfitown,southold.ny,us APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: Barbara Casciotta Date: 5/7/18 Company Name: GreenLo is LLC Name: Robert Skypala License No.: 43858-ME email: Barbara@Greenlogic.com Address: 97 North Sea Road, Southampton, NY 11968 Phone No.: 631-771-5152 JOB SITE INFORMATION: (All Information Required) Name: Edmond Franco Address: 15919 Main Road East Marion NY 11939 Cross Street: Phone No.: Bldg.Permit#: '-f 20 _ email: Fax Map District: 1000 Section: Block: Lot: r BRIEF DESCRIPTION OF WORK(Please Print Clearly) Roof mounted solar electric system 19440k.W 54 SunPower modules with micro inverters SPR-X ?-360-C-AC Circle All That Apply: Is job ready for inspection?: YES /10 Rough In Final Do you need a Temp Certificate?: YES NO Issued On Temp Information: (All information required) Service Size 1 Ph 3 Ph Size: A #Meters Old Meter# New Service- Fire Reconnect- Flood Reconnect- Service Reconnected - Underground -Overhead # Underground Laterals 1 2 H Frame Pole Work done on Service? Y N Additional Information: PAYMENT DUE WITH APPLICATION 82-Request for Inspection Formals � 60 GREENLOGICO ENERGY May 7, 2018 p 15C[ED'V[E D Town of Southold MAY 1 0 2018 Building Department Town Hall 53095 Route 25 BUMDING DEPT• Southold, NY 11971 TOWN OF SOUTHOLD Dear Building Inspector: Please find attached a building permit application on behalf of the Edmond Franco who has engaged us to install a roof mounted solar photovoltaic (PV) electric system for his home located at 15919 Main Road, East Marion, NY. In connection with this application, please find attached: • Building Permit application • A Storm Water Assessment Run-off Form • Certificate of Occupancy Application • Application for Electrical Inspection • 2 Surveys of the Premises • 4 Engineer's Reports (3 originals and 1 copy) • 2 Three Line Electrical Drawings • 2 Spec. sheets of the solar panels • 2 Spec. sheets for Racking System • GreenLogic Suffolk County Home Improvement License • GreenLogic Certificate of Liability Insurance • GreenLogic Certificate of Worker's Compensation Insurance Coverage • Installation Manager's Master Electrician's License • Check for$200 ($50 Building Permit/$50 CO/$100 Electrical Inspection) Please let us know if you need anything else in connection with this application. Yours truly, 044414a 66d&*&4 Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 ext. 117 GREENLOGIC LLC o www.GreenLogic.com Tel 631.771 5152 Fax: 631 771.5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd , Suite 3 200 S Service Rd ,#106 Southampton, NY 11968 Rosyln Heights, NY 11577 GREENLOGIC' ENERGY January 3, 2019 The Town of Southold Building Department ✓ :1' f 54375 Route 25 P.O. Box 1179 Southold, NY 11971 JAN 9 2019 Re: Building Permit No. 42687 r*171U'11!T.IG 17;TV I I"T. Edmond Franco 15919 Rt 25, East Marion To the Building Inspector: Enclosed please find the Engineer's Certification Letter for the above referenced address. Can you please close the building permit and send the Certificate of Occupancy? Please let me know if you have any questions about the installation. Sincerely, VW1&=a 664& ft Barbara Casciotta Account Manager Barbara@Greenlogic.com 631-771-5152 Ext. 117 GREENLOGIC LLC -www.GreenLogic.com Tel: 631.771.5152 Fax- 631 771 5156 SOUTHAMPTON ROSLYN HEIGHTS 97 North Sea Rd , Suite 3 200 S Service Rd , #106 Southampton, NY 11968 RosyIn Heights, NY 11577 ........•... . .......... ✓ ... . ............ ,Y;._£.-.:r.}.�r.}•.�._r..r 3'rr5'�.�.;i"�7��{."�=-..�:..--..�•.Y-F-F;r�t,.:....K r-.r`�...`f..:f.•i.,.'t tiv..t..:..:r•:C�.✓rf',f,,:'�.,:?/�.' ,,i ;,.,:�.:-.�.,r�,.(..._fi,'J�r.7_`€4.,•..,k+.�,.h�.:.�u,.•.'.r3.-r,„.Z,.•.K,rzt:� {:✓.e.a.,.,y,,s.L,3.„,'��,f..”.',',7,y"h,_y'tL,.;,.•..yr.*'`•/r,.�.„t'',iR_�1'...'.,•i?x,e t_r.,t.:.,ar,k..;..`i.-iri;:�t;'�:.st.'`..f�"�`�.-:.t..,.�.y.",i..',,�✓.t..Gyy�p...n t �`rs..tiL1..1.r,.rv.,,;M.;,5t.'r,S.Y;-;4�,„yt,,f,e�Y..r.r�':'.Gii.1(nsx.„rr.'?.`''>+fi<^.lfv Y,,yt. .s','7i�.t.�,,ti„..+,I .�,••t_-..ti,1.E �}' ,l�r �1�r.X.:—.' ,i '�....,z.1�J`,.+7v,.t”-;,:-''a..<�.r+.u 1"'��ti"..•"':.'r MS- % 0 A0 44/ 0- -4 —4, AWR 4 �mj' Suffolk County Executive's Office of Consumer Affairs ; :. R1. MEMORIAL HIGHWAY HAUPPAUGE,NEWYORK 11788 T ' DATE ISSUED: 5/25/2006 No. 40227-H SUFFOLK COUNTY Home Improvement Contractor License This is to certifv that "-N.- 9�9` NURC A CLEJAN doing business as V GREEN LOGIC LLC having furnished the requirements set forth in accordance with and subject to the proons of applicable laws,rules ... ......... and regulations of the County of Suffolk, State of New York is hereby licensed to conduct business as a HOME IMPROVEMENT CONTRACTOR,in the County of Suffolk. Additional Businesses NOT VALID WITHOUT DJ�PARTMEINTAL SEAL AND A CURRENT CONSUNIER AFFAIRS ID CARD Director .......... V ;A' i+ ��,v..��y� \'`1/. :.(��s.`�F� �\\.,•/ - � �:r,. ,\`'r.r �+�, t l \\ �� ,ri�>t \ // \�� ti -\`�-/T ���t`+�i�... \�.�i• l f '�i�, \\•�/ ���' �,v, 1 , I f Suffolk County Executive's Office of Consumer Affairs VETERANS MEMORIAL HIGHWAY HAUPPAUGE, NEWYORK 11788 ' ` 12/10/2007 SUFTOLK COUNTY Master Electrician License .. doing business as / GREENLOGIC LLCi�♦ -' �_� provisionshaving given satisfactory evidence of competency,is hereby licensed as MASTER ELECTRICIAN in accordance with and subject to the ppand regulations o. Suffolk, of Additional Businesses NOT\ �J, if WITHOUT i� \ J \ DEPARTMENTAL SEAL ANDW CURRENT 11)CARD CONSUMER AFFAIRSl Director ,r fi r � V. // l\: h��l - '�` /r ',\ �4•Y J , !/ \\.. - v CERTIFICATE OF LIABILITY INSURANCEDATE(MM/DDIYYYY) F01/29/2018 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER CAGNracr Brookhaven Agency,Inc. Brookhaven Agency,Inc. PHONE 631 941-4113 FAX 631 941-4405 128 Old Town Road Suite C EMAIL , brookhaven.agency@verizon.net PO BOR 650 PRODUCER East Setauket NY 11733 INSURERS AFFORDING COVERAGE NAIC 0 INSURED INSURER A: HDI Global Insurance Co. Greenlogic,LLC INSURER B: Merchants Preferred Insurance Co. 97 North Sea Rd,Suite 3 INSURER c: First Rehab Life Insurance Co. Southampton,NY 11968 INSURER D: Endurance American Insurance Co. INSURER E. AGCS Marine Insurance Co. INSURER F. National Liability&Fire Insurance Co. COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXPim LIMITS GENERAL LIABILITY EACH OCCURRENCE $1,000,000 A X COMMERCIAL GENERAL LIABILITY X X EGGCR000076918 01/31/18 01/31/19 DAMAGE TO RENTED $100 000 CLAIMS-MADE I OCCUR MED EXP(Any oneperson) $5,000 X XCV PERSONAL&ADV INJURY $1,000,000 X Contractual Liab GENERAL AGGREGATE $2,000,000 GE N'L AGGREGATE LIMIT APPLIES PER PRODUCTS-COMP/OP A $2,000,000 POLICY FXI PRO- LOC $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT (Ea accident) $1 000 000 B X ANY AUTO x CAPI043565 8111!17 6/11!18 BODILY INJURY(Per person) $ ALL OWNED AUTOS BODILY INJURY(Per accident) $ SCHEDULED AUTOS PROPERTY DAMAGE X HIRED AUTOS (Per accident) $ X NON-OWNED AUTOS $ X UMBRELLA LIAR X OCCUR EACH OCCURRENCE $1,000,000 D EXCESS LIAB CLAIMS-MADE EXC30000250901 1/31/18 1/31/19 AGGREGATE $1,000,000 DEDUCTIBLE $ RETENTION 0 $ WORKERS COMPENSATION XW C STATU- OTH- AND EMPLOYERS'LIABILITY RV I Ir�A F ANY PROPRIETOR/PARTNERIEXECU I ITJN/A V9WC857891 6/15/17 6/15!18 E L EACH ACCIDENT $1,000,000 OFFICERIMEMBER EXCLUDED? (Mandatory in NH) E L DISEASE-EA EMPLOYEE $1,000,000 If yes,descnbe under DESCRIPTION OF OPERATIONS below E L DISEASE-POLICY LIMIT $1,000,000 C NYS Disability D251202 4111/17 4/11/18 Statutory Limits E Installation Floater/Pro a MX193076366 4/15/17 4/15/18 $300,000 $1,000 Ded DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (Attach ACORD 101,Additional Remarks Schedule,If more space Is required) CERTIFICATE HOLDER CANCELLATION TOWN OF SOUTHOLD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN BUILDING DEPARTMENT ACCORDANCE WITH THE POLICY PROVISIONS. 53095 ROUTE 25 SOUTHOLD,NY 11971 AUTHORIZED REPRESENTATIVE <NSZ> ©1988-2009 ACORD CORPORATION. All rights reserved. ACORD 25(2009/09) The ACORD name and logo are registered marks of ACORD "EW Workers' STATE Compensation CERTIFICATE OF Board NYS WORKERS' COMPENSATION INSURANCE COVERAGE Ia.Legal Name&Address of Insured(use street address only) 1 b.Business Telephone Number of Insured 631-771-5152 Greentogic LLC 425 County Rd 39A Suite 202 Southampton,NY 11968 1 c.NYS Unemployment Insurance Employer Registration Number of Insured Work Location of Insured(OnlymqukW ffcoverage Is specffkelly#mlfed to .Federal Employer Identification Number of Insured or Social Security certain locations/n New York State,l e.,a Wrap-up polky) 1dFd Number 20.3801194 2.Name and Address of Entity Requesting Proof of Coverage 3a.Name of Insurance Caller (Entity Being Listed as the Certificate Holder) National Liability&Fire Insurance Co. Town of Southold Building Department 3b.Policy Number of Entity Listed in Box"1a" 53095 Route 25 V9WC857891 Southold,NY 11971 3c.Policy effective period 06115/2017 to 06/15/2018 3d.The Proprietor,Partners or Executive Officers are included.(Only check box if all parmandatBcers Included) all excluded or certain partners/officers excluded. This certifies that the insurance carrier indicated above in box 7"insures the business referenced above in box'1a"for workers' compensation under the New York State Workers'Compensation Law.(To use this form,New York(NY)must be listed under Item 3A on the INFORMATION PAGE of the workers'compensation insurance policy). The Insurance Carrier or its licensed agent will send this Certificate of Insurance to the entity listed above as the certificate holder in box"2". Will the carrier notify the certificate holder within 10 days of a policy being cancelled for non-payment of premium or within 30 days if cancelled for any other reason or if the insured is otherwise eliminated from the coverage indicated on this certificate prior to the end of the policy effective period? YES ❑NO This certificate is issued as a matter of information only and confers no rights upon the certificate holder.This certificate does not amend, extend or alter the coverage afforded by the policy listed,nor does it confer any rights or responsibilities beyond those contained in the referenced policy. This certificate may be used as evidence of a Workers'Compensation contract of insurance only while the underlying policy is in effect. Please Note:Upon cancellation of the workers'compensation policy indicated on this form,if the business continues to be named on a permit,license or contract issued by a certificate holder,the business must provide that certificate holder with a new Certificate of Workers'Compensation Coverage or other authorized proof that the business is complying with the mandatory coverage requirements of the New York State Workers'Compensation Law. Under penalty of perjury,i certify that i am an authorized representative or licensed agent of the insurance carrier)referenced above and that the named insured has the coverage as depicted on this form. Approved by: Nicholas Zulkohke (Print name of authorized repreaentaNve or licensed agent of Insurance carrle0� Approved by: (signature) If (Date) Title:Authorized Agent Telephone Number of authorized representative or licensed agent of insurance carrier: Please Note:Only Insurance carriers and their licensed agents are authorized to issue Form C405.2.Insurance brokers are NM authorized to issue it. C-105.2(9-16) www.wcb.ny.gov " t 7 APP OV I AS NOTED DATE:s- �- B.p. 7 ELECTRICAL FEE:- S DD BY: INSPECTION REQUIRED NOTIFY BUILDING DEPAR NT AT 765.1802, 8 AM TO 4 PM FOR THE FOLLOWING INSPECTIONS: 1.-FOUNDATION - TWO REQUIRED ''FOR POURED CONCRETE 2. ROUGH FRAMING & PLUMBING 3.,INSULATION 4. FINAL-- CONSTRUCTION MUST BE COMPLETE FOR C.O. ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW YORK STATE. NOT RESPONSIBLE FOR DESIGN OR CONSTRUCTION ERRORS. COMPLY WITH ALL CODES OF NEW YORK STATE & TOWN CODES AS REQUIRED AND CONDITIONS OF 1%9{QI4TQmIl8L SObTNOM ARD IM I= OCCUPANCY OR USE IS UNLAWFUL WITHOUT CERTIFICA7 OF OCCUPANCY Pacifico Engineering PC Engineering Consulting 700 Lakeland Ave, Suite 2B Ph-631-988-0000 Bohemia, NY 11716 PC c solar@pacificoengineering.com April 24,2018 X� J Town of Southold Building Department 54375 Route 25, P.O. Box 1179 Southold, NY 11971 Subject: Solar Energy Installation for Edmond Franco 15919 Main Road East Marian, NY 11939 have reviewed the roofing structure at the subject address.The structure can support the additional weight of the roof mounted system.The units are to be installed in accordance with the manufacturer's installation instructions I have determined that the installation will meet the requirements of the 2017 NYS Residential Code(2015 International Residential Code-2nd Printing modified by the NYS Budding Standards and Codes 2017 Uniform Code Supplement), and ASCE7-10 when installed in accordance with the manufacturer's instructions. Roof Section A B Mean roof height 22.0 ft 11.6 ft Pitch 5 degrees 5 degrees Roof rafter 2x10 117/8 BCI 90 2.0 Rafter spacing 16 inch on center 16 inch on center Reflected roof rafter span 12.8 ft 17.3 ft Table R802.5.1(1)max allowable 20.6 ft 31.5 ft The climactic and load information is below: CLIMACTIC AND Ground Wind Live Load, Point GEOGRAPHIC DESIGN Exposure Snow Speed,3 Pnet per pullout Fastener Type Category Load,Pg, sec gust, ASCE 7, CRITERIA psf mph psf load,Ib Roof Section A D 20 130 31 424 (2)5"&(6)3"#14-13 DP1 concealer - screws B 28 383 (2)5"&(6)3"#14-13 DP1 concealer screws Weiaht Distribution array dead load 3.5 psf NE{N y load per attachment 47.9 Ib �q �qN PAci,�,coq Subject roof has one layer of shingles. c O Panels mounted flush to roof no higher than 6 inches above roof surface. Ralph Pacifico, PE 0 , 2 Professional Engineer ESS GREE IL®GIC® ENERGY GreenLogic,LLC Approved Franco,Edmond 15919 Main Road East Marion,NY 11939 Surface#A: Total System Size: 19.440kW Array Size:8.640kW 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker Azimuth:320° Pitch:5° 2 Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X22-360-C-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" x x x x Array.38'4 9/16"X 12'1 1/4" "999 - Surface:40'3"X 13'6" Magic#:Invisimount Legend: ® 24 SunPower 360W Panels o SunPower Invisimount Rail 49 Eco-Fasten Fast Feet B B 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: OF NS Gs� QH PA�i,9c O tz W 2 cn�`o/oR 066182 �FESSIO�P Drawn By:MA Drawing#1 of 8 Date: 1/2/2018 REV:A Drawing Scale:3/16"=1.0' (3�GREE 9L®CIC® ENERGY GreenLogic,LLC Approved Franco,Edmond 15919 Main Road East Marion,NY 11939 Surface#A: Total System Size: 19.440kW Array Size:8.640kW 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker Azimuth:320° White EPDM Pitch:5° 2 Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X22-360-C-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:38'4 9/16"X 12'1 1/4" Surface:40'3"X 13'6" Magic#:Invisimount Legend: 1-341 ® 24 SunPower 360W Panels o SunPower Invisimount Rail 49 Eco-Fasten Fast Feet B 2x10"Douglas Fir Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: ,," PAC, '0,� ro ZkP�OA 06618?- ROFESSIONP Drawn By:MA Drawing#2 of 8 Date: 1/2/2018 REV:A Drawing Scale:3/16"=1.0' GREENLOGIC® ENERGY GreenLogic,LLC Approved Franco,Edmond 15919 Main Road East Marion,NY 11939 Surface#A: Total System Size:19.440kW Array Size:8.640kW 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker Azimuth.320° Pitch:5° 2 Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X22-360-C-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" 1 2 Array 38'4 9/16"X 12'1 1/4" Surface:40'3"X 13'6" Magic#:Invisimount Legend: ® 24 SunPower 360W Panels o SunPower Invisimount Rail 49 Eco-Fasten Fast Feet N N 2x10"Douglas Fir Rafter 16"O.0 1 Notes• Number of Roof Layers: 1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf Engineer/Architect Seal: OC NEJ- CO W jP�OA 06616S' v 9�FESS1 Drawn By:MA Drawing#3 of 8 Date: 1/2/2018 REV:A Drawing Scale:3/16"=1.0' (G�GREENL®GIC® ENERGY GreenLogic,LLC Approved Franco,Edmond 15919 Main Road East Marion,NY 11939 x x x - XIX x Surface#B: Total System Size:19.440kW Array Size: 10 800kW 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker 1 circuit of 6 on a 20A breaker Azimuth: 140° Pitch:5° Monitoring System: 2 SunPower x x x x x Panel/Array Specifications: Panel:SPR-X22-360-C-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'10 7/8"X 25'9 15/16" Surface:22'8"X 28'2" Magic#:Invisimount Legend: ® 30 SunPower 360W Panels- ---Ix x x ® SunPower Invisimount Rail • 56 Eco-Fasten Fast Feet Ny 7 F Ny \�y N 8 B BCI 90's 2.0x12 Rafter 16"O.C. Notes: Number of Roof Layers:1 Height above Roof Surface:4" x x x X— x x Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf V7 7 Ny Ny V N Engineer/Architect Seal: of NE COA e%A PAx x x _ I V Ny Ny N CoA os61 a2 R�FESSIONP�' Drawn By:MA Drawing#4 of 8 Date: 1/2/2018 REV:A Drawing Scale: 1/4"=1.0' White EPDM GREENLOGIC ENERGY GreenLogio,LLC Approved Franco,Edmond 15919 Main Road East Marion,NY 11939 Surface#B: Total System Size:19.440kW Array Size: 10.800kW 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker 1 circuit of 6 on a 20A breaker Azimuth: 140° Pitch:5° 1K Monitoring System: 2 SunPower Panel/Array Specifications: Panel:SPR-X22-360-C-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'10 7/8"X 25'9 15/16" Surface:22'8"X 28'2" ----t------ Magic#.Invisimount Legend: ® 30 SunPower 360W Panels ® SunPower Invisimount Rad • 56 Eco-Fasten Fast Feet BCI 90's 2.0x12 Rafter 16"O.C. Notes: Number of Roof Layers•1 Height above Roof Surface.4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf IZ. Engineer/Architect Seal: z � w Zct� 066182 tCi RoFESS10NP�' Drawn By:MA Drawing#5 of 8 Date: 1/2/2018 REV:A Drawing Scale: 1/4"=1.0' GREE IL®CIC® ENERGY GreenLogic,LLC Approved 4L ZLII 4� Franco,Edmond 15919 Main Road East Marion,NY 11939 3 Surface#B: Total System Size: 19.440kW Array Size: 10.800kW 1circuit of 12 on a 20A breaker N/ Ny �=Slyx 1 circuit of 12 on a 20A breaker 1 circuit of 6 on a 20A breaker Azimuth: 140° Pitch:5° Monitoring System: 2 3 SunPower Panel/Array Specifications: \V N/ Ny N/ Panel:SPR-X22-360-C-AC Racking:SunPower Invisimount Panel:61.39"X 41.18" Array:20'10 7/8"X 25'9 15/16" �L ZL ZN --AL' Surface,22'8"X 28'2" Magic#:Inwsimount Legend: 4 ® 30 SunPower 360W Panels ® SunPower Invisimount Rail • 56 Eco-Fasten Fast Feet ;y Ny IV--- - ----- -Ny T77 H BCI 90's 2.0x12 Rafter 16"O.C. 4L ZL L Z�....... Notes: Number of Roof Layers: 1 Height above Roof Surface:4" 4 =Ny Materials Used:Eco-Fasten,SunPower Added Roof load of PV System.3.5psf Engineer/Architect Seal: ®F NE�L ZL ZLI 4L------- �y ��eH PAQFic0 5 W NyNy N7 �O00 06618 RoFESSIOXA Drawn By:MA Drawing#6 of 8 Date: 1/2/2018 REV:A Drawing Scale: 1/4"=1.0' No vent Pipes Will Be Covered By The Solar ArraX GIEELOGIC® LEGEND: UENERGY AR -Access roof per R202 definitions RAP -Roof access point-to be away from RWV -Roof with valley, GreenLogic,LLC Approved overhead obstructions,doors, 18'minimum from valley windows,decks,fences,landscaping Franco,Edmond GA -Ground access area per R324.7.3 width AP =Access Pathway.36"minimum SVO -Smoke vent operation per 15919 Main Road to be same as AP as measured at eave width per R3241A and R324.7.5 R324.7.7,18'minimum from ridge East Marion,NY 11939 Total System Size: 19.440kW 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker 1 circuit of 6 on a 20A breaker 24 SunPower Azimuth: 140' 360W Panels Monitoring System: SunPower Panel/Array Specifications: Panel:SPR-X22-360-C-AC Racking:SunPower Invisimount 4S 4s Panel:61.39"X 41 18" Main Array:66'7 7/8"X 70'6 3/4" Surface:80'10"X 73'5" House f-----------------------1 Magic#:Invisimount I I Legend: I I API AP ® 54 SunPower 360W Panels SunPower Invisimount Rad 1 I • 105 Eco-Fasten Fast Feet I I 8 2x10"Douglas Fir Rafter 16"O.C. GA GA D 8 BCI 90's 2.0x12 Rafter 16"O.C. RAP Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3.5psf 30 SunPower Engineer/Architect Seal: 360W Panels ®F NES y PAC®moi ®'� Garage xIxCr Meter I LU N =C? ®,o 066182- ki R�FESSIONP Drawn By:MA Drawing#7 of 8 Date: 1/2/2018 REV:A Drawing Scale: 1/16"=1.0' GREENLOGIC" ENERGY GreenLogic,LLC Approved Franco,Edmond 15919 Main Road East Marion,NY 11939 RUM Ut CW. MI WHIOW Lit C Total System Size:19.440kW 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker 1 circuit of 12 on a 20A breaker Epp. "Fast Feg"ElaseqaLe 111 1 circuit of 6 on a 20A breaker EaAmbm'rstFe&'alXTlt'lffloik III Azimuth: 140° EbaFbam"F�stFeet'"1AHW9I1Mas7rg Im Monitoring System: 2 #14,B&CH CctulerScrew 210 SunPower .W'CH Ca-mdg-SaEw E33 I Panel/Array Specifications: Panel:SPR-X22-360-C-AC _ Racking:SunPower Invisimount Panel:61.39"X 41 18" Array:66'7 7/8"X 70'6 3/4" Surface:80'10"X 73'5" Magic#:Invisimount Legend: ® 54 SunPower 360W Panels SunPower Invisimount Rail • 105 Eco-Fasten Fast Feet OU 2x10"Douglas Fir Rafter 16"O.C. H BCI 90's 2.0x12 Rafter 16"O.0 Notes: Number of Roof Layers:1 Height above Roof Surface:4" Materials Used:Eco-Fasten,SunPower Added Roof load of PV System:3 5psf Engineer/Architect Seal: PA � O r— I � 2 066182- R�FESSIONP Drawn By:MA Drawing#8 of 8 Date: 1/2/2018 REV:A Drawing Scale-1/16"=1.0' PV—SA-1 N.W EQUIPMENT — — — — EXISTING S—RVICE AC—COM91NFR PANE- 120/24C, 1;'H, 3W AC—CMD-1 .Of (PV tGAC3S DNI)) } , PV—SA-2 430A'` PV—SA- # g N tCz • • • BKR-1 AC—DSC-1 N . . • 9 1 ! ` AC DISCONNFCT BKR-2 ( PV—SA—A t . . . i 3KR—s ° PV rA 5 I I ( BKR-4 MAIN �' • • • �1 • • • 2 f ' 6KR-5 # B N J � � ° rFJ!S3EDf I ILGC C 1 N + N i EGC i Etat EXISTIN rNC 6�A XISTING 1F i GEC GEC -®- PROPOSED 3-LINE ELECTRICAL DIAGRAM REVISIONS Franco, Edmond '" 15919 Main Road EEN E NFRCV East Marion, NY 11939 ELIMINATING THE COST OF ENERGY 1 ) INITIAL SUBMITTAL WITH APPLICATION Page 1 of 3 Drawing No: Franco-3LD1 Revision: 1 Revised: 12/20/17 EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION PV-SA-1 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-X22-360-C-AC, 1-CIRCUIT OF 12-MODULES PV-SA-2 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-X22-360-C-AC, 1-CIRCUIT OF 12-MODULES PV-SA-3 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-X22-360-C-AC, 1-CIRCUIT OF 12-MODULES PV-SA-4 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-X22-360-C-AC, 1-CIRCUIT OF 12-MODULES PV-SA-5 PHOTOVOLTAIC SUB-ARRAY SUNPOWER SPR-X22-360-C-AC, 1-CIRCUIT OF 6-MODULES ELECTRICAL LOAD SUMMARY AC CIRCUITS TAG POWER, MAX VOLTAGE MAX.AC VOLTAGE, NOMINAL RANGE CURRENT PV-SA-1 4320 WATTS 211-264 VAC 17.56 A AC 240 V, AC PV-SA-2 4320 WATTS 211-264 VAC 17.56 A AC 240 V,AC PV-SA-3 4320 WATTS 211-264 VAC 17.56 A AC 240 V, AC PV-SA-4 4320 WATTS 211-264 VAC 17.56 A AC _ 240 V, AC PV-SA-5 2160 WATTS 211-264 VAC 8.78 A AC 240 V,AC PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Franco, EdmondO 15919 Main Road u3u� ENERGY East Marion, NY 11939 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 2 of 3 Drawing No: Franco-3LD1 Revision: 1 Revised: 12/20/17 c� - EQUIPMENT&COMPONENT SCHEDULE TAG DESCRIPTION SPECIFICATION AC-CMBP AC COMBINER PANEL 250V,200A,NEMA-1,1-PH,3-WIRE BKR-1 CIRCUIT BREAKER,PV-SA-1 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-2 CIRCUIT BREAKER,PV-SA-2 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-3 CIRCUIT BREAKER,PV-SA-3 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-4 CIRCUIT BREAKER, PV-SA-4 MATCH AC COMBINER PANEL BRAND,2-POLE,20A BKR-5 CIRCUIT BREAKER, PV-SA-5 MATCH AC COMBINER PANEL BRAND,2-POLE,20A AC-DSC-1 AC DISCONNECT SWITCH(LINE TAP) 250V,60A,NEMA-1,FUSED; FUSE RATING:60A CONDUCTOR SCHEDULE TAG TYPE CONDUIT AWG. / EGC A USE-2/PV/UF 3/4"PVC-40 12 / 6 B THWN-2 2"PVC-40 4 / 6 C THWN-2 2"EMT 4 / 6 1.)CONDUCTOR TYPES AND SIZES TO BE ADJUSTED FOR TEMPERATURE,DISTANCE,AND DERATING FACTORS. 2.)ELECTRICAL CONDUIT TO BE MIN.PVC SCHEDULE 40,ADJUST FOR SITE CONDITIONS. 3.) ALL ELECTRICAL MATERIALS AND INSTALLATION METHODS TO COMPLY WITH NEC AND LOCAL CODE REQUIREMENTS 4.) NOTE:GROUNDING ELECTRODE CONDUCTOR TO BE#6 COPPER. PROPOSED EQUIPMENT SPECIFICATIONS REVISIONS Franco, Edmond 15919 Main Road N RGY East Marion, NY 11939 ELIMINATING THE COST OF ENERGY 1.) INITIAL SUBMITTAL WITH APPLICATION Page 3 of 3 Drawing No: Franco-3LD1 Revision: 1 Revised: 12/20/17 ,z amlll 511 e Design-Driven Advantages #1 module aes'_he_c.s arnd c:l cierncy1 X 949°P P!, . IJnmaCcrie rno cereiaility= I. ..,.. ��a SERIES No e'<ecrro v,k capac. ors 25-year Combir,eo P veer and Fron a:t Warran,y- Max:mlze Valje for Roo' Size sys;.em for roof,not strlrg inver;.er optirrtze performance c.,f"eac{,rfiooule Expand Deployment Options Complex roof's arid partial shading Sma systems System expandability Simplify&Speed Installation Ootim*ze System and Insta.lat:on Efficiency Factory-Integrated miC"roinvert'er Robust,douc'le-,ockirig AC cora nec'mrs Suri Dower,`-AC Modu us ;nff'ch incll_x r I ctoly ntcgrdtecl Desgn flex'Gility Uffsi,e and or`S',e SurPcvver r"f r cir'vrrt:,,() ;JIC'P?,rc?v0 t1t Or aiy r(iITIC; ld:l:;n Gi`iigh Nc; DC string sizing process e'fIclen y,h gn rella^ky,ar:�module-eve,DX-to-AC power corverslon Fewer°n>ral(atior;steps than competing sys`erns Desigred spec4`ical;y for use v^vltn Si,n_,�IUwe"IrivislI'VoJfit"-1dt`le Intuitive Commissioning Su'I`(;W,_`I Ur',toring Sy_ [eM,SunPo.trer AC l'tilc)mles e,iab:2 r uoo ristal'- c,n,ucst in-class sy'stern a,�sthet cs,and r tGiU�c visiui!It�I a Component of COMplete System r. Sy>ler perrormdncr, All to 5 Cor,:?S WIJ,d-ie br'S4 C Urr'C)IrCC PU'v1"er BIfbT use With and the SunPower Mc:n'toring System and Pr.:duck Warranty In rhe Irclus'r/ S.iperior system rel<abrii t anti aesthetics N sunpower.com 4 —4, 4' ' ,a F: 77 77 SPR-X22-360-C-AC ODerat,ngTemp /10'F-o"185' 40'C to 851(") I---------------- - ------------ --- -- ---- r--I ------ --- ---- -'- 0 --- NominEl Pov,,,1er`fPn,-)rn) Max A'T1,)ler1L (SO,C) -P-ov,erToIor--nc-e-'- Tomo ------- ----—-- - ------ AAII.nd 62 ps�'3000 Pa-305 kg/m2 17'c-it&.,z(:k �-Avg 22 21�5 M.jx I oad Snow 12E psf,CGOO Pa,611 1 1<g/M2 frcnt le,rip Coenf (Povier) 0 2 9 DA:/"C' ' nch(25 rnr,,-,l diameter hall at 52 mph(23 -h-e byzca'ss diode� I'T)PFCL Resistai ce Shace Tolerance inutgrated troci e-level max wurr pc"ver point track ng Mill 1: .,F.-y2a-limlle-,povver wF,rany -5-YOKTrted Drod,ct-vjar,artY--- 'Dotpor @ 2,10 v'r-ir/nom/max 2<0,126A V jU lisred to UL 17.1,ii-cludin,7 183/208/2-19 V 1Fz-E1 541,1 SA-7a and FFF1 547'/1547 a Utility Ope,pt,I-S Frequency(m n/nom/max) 01160 5 H, Wterar--Live 0,.tp,jr Power�a,--Lor"min) F`,'Rapid-,-tdoovvn Eq,j.-,,n,,n' ,-i , AC Max CoizinL.'lDLJ'-,,jtp,it Cur-en' 2z'O V 1 33 A EquqDn-e : .,,oi ind no AC Wax CO"ILMUOU�0,,tput(�ur,�-nt Cj--)(18 v '1 54A 1,L 6703,UL 97"OS Coine,-tors and cables(Lad bi eak rlisconr(-,--t,()n) AC Max Co',, 0 YA)U,POV'Yer 320 W L L 1703-°b`Mod�jies(Type 2 lire rating)-C-or-w-e-r-si-o--i Ef.�c�--n-c� -,- -96 u,14, Max Ug is Pe,20 A Rrarcri 240 V I-'(Sin7 e phase) Certifications F-ipblesirista-lati,)ri,-,acco;loner viith N L'1-69 0 6 MdX U'l LS Ile,-20 A Branch Cir(-w',ti 2u3 V i 0(tvvc pole) NEC i5,90 12 Raorc S,-,,jtdcv-jn(i-isv:Ie ar d cuts de No active Oase oal-4n(-rig for 3 pursetho ar-jl%,,1 1__irsta Jamons ie Nof s,650 33(A)-(E)") L iD901tAC:Co�i, ,-t I-CC and iCCS 003 Cl&,s B NV I-:7 "p, 'AN WN-i-i w;ed with Inv,siMount aching(UL 270'i) -- Solar,Eels _C46 Vciocly;tzllme Mzxecn Gon ill Irtel-ratod gro.jn�ji-g and bmr,,ing Ngh-vansmiss on emperea glassvvivi F,ont Glass in re"oCt'vC. Cass Afire rated --- PID Tr,;j Dcliertial -nd „-�.-d d-graica.iori n-ce rEnv'�p",rrlental Ra -rig OlAdoor r3le-, ------- Gas�,1 black ar-odized(highest AA,%/1A rating) ''veigv-t 5 1) b• s(2 0 6 k 280 11 ------------ ---—--- --- 02,r,-, RCCOMITle!Ide-M6X NJI.Odule Spau'lg 3 n (T;ri-im) 1107 n m [43 6 in] '040' 111 J-p-,-of wnf 3,21.0 s I mn pines rhrtor MOA,e S,xvy rel)2(,1 ;I I lvint-�t- ,.Lk 1--b 2T2 ivc out ti-E- rT,'1l,fY'L IQF, [cSLed--n,,- Z'eta 'Sun�)o::er Uor-t I r and vd-=g- Based on verage vf,r-!asL re--,,i...... uiccu-u,i Please read the•,ci,-ty and instal a:jon instructions fo,cei-a,ls Se«1,1AIM A10i LO”/f3y:�tl`I`G,d refe-i ice if,,r;otvf I Fat MOIL JZ-,a IS,SeL' d(.-,-'dat;,l-et'04MV11 SL I 11-0"".T'-C'11/d jtlsll,utb Document 4 316046 Rev D/LTR_US ZV 1:^`-o �d�R F`^'c'• P�,., ^. a..•7r.::: _ :Wim... <'=�e-._,&'a,.'.:. ;nS' -dim:<:.sa.?'S' -S.e ` > ..° =,.` 8 z IN %e e '91 ft Simple and Past Installation I 1,itegraLed module-to-rail grounding are-assembler mid and end clamps' Levitating raid camp for easy placement a Mid clamp width`acr'itates consistent,even - _ � - F•`<'' module spacing Simple,ore-draled rail splice UL 2703 Listed integrated grourd,ng Flexible Desigr w _ �� sem'�• 6 Adoresses nearly all sloped resr<ential rco,s Design in landscape and oortrait Y Rats enable easy obs.acle rranagerrem " Customer-Preferred Aesthetics #'1 module and t`1 mounting aes:hetcs t Bes,-rn-class systern aesthetics Elegant Simplicity Premium,low orclile design Blackanodi7ed cotiiponents SunPower'� Invlsilviount-T"11 is a SunPower-designed IF then mrd clamps arc end clamps rail-based mounting system. The I;visifviount system and capped,flush rails addresses resideni,a, sloped roots and combires faster Part of Super'or System instal,az,on time, design flexibility, and superior aesthetics. Bullt for use with SurPower DC and AC modules The Ir;vlsf{b cunt product was specifically envisioned and Best-in class system reliability and aesthetics Combine yr ith SunPower rnodules and engineered to pair with SunPower modules The resulting monitoring app system-level approach will arnplily the aCSdier c and installation benefits for both homeowners and installers • z` r k(� �M iIlltff � sunpower.com .. :,,^ n7��•�.�,-g T • - ', �=�BF.i xE aw� r Jt n ''�,n < 4%C0. ,�"�, „R, , iom Jig 11 Moc_Lx i Mud Clamo and Rad Module*r'End C ane and Rad 99wwl z . O�F�Z.g ��_.,..,.-...M..x.." �.m...... �......."...,..<�.....-....:3:>��..a.w.....a.�..a•sw.x.S•....,..R Mid Clamp Enc C amp Pail&Rani Splice Ground Lug Assernbly End Cap g � . N"`M j Tiemperaturc -40°C to 90'C(-40`F to 19:°�,- -- j Ccmponent Material Wright r—------ , tvlax Load(L R;D) ; ' 3000 Pa uplif_ 1 Mid Clamo :lack ox de scairiess steel AtSI 304 63=(2)oz) i _ - 6000 Pa:'osvnfoi ce Erid Clamp Black anodized aluminum alloy 6063 I"6 110 {3 88 oz) i - -------- - - -- - -- -- Ra' Black anndi,r c,altarn num alloy ag05-T6 8 u g-m{9 or/ft) Rai Splice Af-mmum alloy 6005 T5 830 gr•r(9 oz/ft) I i 25-year prort,ct.vjnanty --- - -- T -I -- -i ivarranhes GrUU1iU uJ; 304 sea ntess 1U6 5 gtrn(3 75 oz) j 5-year Cr s-h tivarranty Assembly (A -?0 bolt,tin-plated tonne,hug) 1ra Cap Bla2ck ` - acual(POM)t opnlyrrci 1 G g(U 3?oz) I -------- —0 ( - Ul 2703 L sired r; [Certificatiors Class A Fire Mated - - - I i I Composition Sh+ngle ratter Attachment Compos•ticr Shingle Rcof DerkrgAttachmen: App'ication > Curved and Flat du Root Att,,chirrent i Ur,-vetsal Interra(e•or Char Roo(At-acnne-s i Refer to r;&,!txhment hardware manufacturer's do:urnenlalion — 1 a 0aclule Er;mr mar n:omoaUbie a;n the Inv,;[,APunt sy=tem renwiPcl fo,harlw ire INProoeraF+la; 7t7 i S Sw dower Cnm;;ra:�n All Rights Reserve^ Nv SIMOJNT a+e;radcmp,ks o•+egtstered radPrar<,et Sur�ew.er:ors a ro� All othe,traaerrars aro the orcce-y c`tear,esper6ve wirers sunp0'+ver Com Spec,'kaaons Irduued, Document#509506 Rev,' b b FRANCO ASSr� GARAGE MEETS&BOUNDS BY. ,„„� '.` __— — _—____--- _ ___.__ ` a3•-I-�I I JOHN MINTO LAND SURVEYING FEBRUARY.2017 _ '——— ——-- — — � .—.--. __ r—r-. J __ _—• , lalsr owvexvA 1 ' � •, $' I I•'t t 3 I cm�iETFE-1—1 • 1 r e. -------- ------------ 1 '� a I� T119 PERMR I• g�: 'ZM-°RESIDENC.Es B�A�1CK�llNE. II I I �I: PPavWE - I __________________ _ _TM - g '•' I � I I I / _._ 1 � Ute\ I " I .� I : I I ! �I I \` � �`\�=� _—.—.—.3.--.—.— .—.—.—.. plft0 pp�rvEwA •�—.————n,n.• �. I Ll. 1 —— 1' ' ' , I .—.—.—.—.—.—.—.—.._. .—.�--.—.`.—_—.—.—•—• \1• ------------- 1 • s,.,c rum. ra mwn. r-- ='----=--- ! I ,om N(�) SITE PLAN 2 SITE PLAN,CONTINUED _ RYALL SHERIDAN ARCHITECTS t1 AVMF.SUUE= PROJECT INFORMATION DRAWING LIST ficetmseaao w.�,m.R•m,wem.wR MCH E RA N C O GARAGE = ADDRESS GOD, G^N�GESII RmprQ.FCt4�fO8tlUtM14JG(bT �• Is 6919Man Raad AI G-R-CE LO0R8ROGFPIANS FavN,NY71999 � �BEyp�g cs�PROPOSEDDC N��UOMON AUGUST 17TH,2017STRUCTURAL S6 O^RAGE FOU"4ATION&RNMNGfl &SECIKWAPPMCABLECODE —5FIGaa e,�tMMNYSsS EGCasatl ".NY S'Ala TO1YN OFSOUTBOM--NO DISTRICT R- m— P,.—!G: ;z�6 , COVER PAGE& SummcouNrvTm. DRAWING LIST F ,aao-z+o,e, LOTAREA 2,> 9C Cv^S V fl� SQUARE FOOTAGE G000 FRANCO ASSN \ GARAGE q �Igpb� - ; �-_--___-___-_______- -_-_______-____--_-__- \� 15919 NaFRwC aa•�.I�0.1� MEET 58 BOUNDS By m,,,,,�„u,,,�,,,,\' , _ ____.. JOHNMINTOLANDSURVEVING FEBRUARY.2017 1 , P Dx..L,-D91.Ew.Y II ' --- Ell, ogre nom,.. - t_•__... { _. —=— _ r. ______1+ FDs\� iN .I _____ ___________________________ \ ro 1 All EAOF 0 t l i ___..,_a--t , I \\'1 I� HISPERMIT 6 S43 �; ��•?^^„,L'�'n„ ! �I I ;I ,+` `� �•, EDS I • 1 1•'i I i � ' //�����Np�FSID=LESc�yACKLINE � _-___ _ _ . i tT I rr I i , ��SDDP=L9EIDACKLINE I\ _ a , _ r..wo nwo n oz,a 1 91 I \\. •��'�� �.-_.---I ------- aug:onD.,N ..r —————.——.v.- J ----------•— i IL'.�.�;o:,—•—.—.I-. I r N SITE PLAN,CONTINUED �� 1'�3C-0• � 1 RYALL SHERIDAN ARCHITECTS 174 51HAVB VE,WM= NEW YORK NY 10010 PROJECT INFORMATION DRAWING LIST F��� ��^�I/,�� /� �•� /� //'���a pRCHRECNRAL F mnc l IA\FI I/ ••® G,/" PL-11 !]T1!/=11... ADDRESG 6000 GMAGESRE RAV PHNECT NFOBDRAWWG LL9t 11'11—Illr-i1\I i If11 WV111`l� !/iri\U III•SLL,!/t'.1�'\1lT`�U571L��' 15919M1knR AIGI G4RM,EFLOOR&ROOFFU _ Fu1N NY 11939 _ Ap2 GNUGEB AI S /UPEo�Aq 4�^ AUGUST 17TH,2017 PROPOSED CONSTRUCT ON Nee,Acre.1wySuo 0are9e Sfi OA4AGE FdJN'[NPCN SRzAMN3 RPN58SECRON ���db APPLICABLE CODE. ,I P 2015ROav 10der1MNY Sa'e IxlCo-ar 1-11 20151ECC azadAleD W NJ S"Ne TOWNOFSOUTHOLDZONINGDlMICT - R-00 HEIGHT Rsm�G—w COVER PAGE& z s nxzmm DRAWING LIST SGFFOLK C011NTYTA%f �, 100023 Ot B 1 LOTAREA SOU AcEF CGS©00 94,5^6 tt* SQUARE FOOTAGE _ 6]69 PUPU,�09rC45s - - r"' - _ ,_-` ,._qr-'_.�.% _ ... - ..- •• _ ' ,-c -- -5 - .._ _�. ''�� - ---,._-.-...- --r -,-r-.-ems.^.=;=.^.r-• __..,.s �y POOL BARRIER KEY ' 4 Tax Map X1000-23-01-10.1 I 5 6 LAND NOR OR FORMERLY OF __JE_ANNINE T. JAYNE _____ ___ __ ------------------ POOL CODE FENCE / / / _ ---- ----------_-------------- ' ----- - 960 1112 SOLID POOL CODEIBARRIER MIN. — UNDS BY: a'0"ABOVE ADJACENT GRADE / / / ` -------- — _--_-- _ --__ i r---- COASTAL EROSION HAZARD LINE / / _rte"' — •, LAND SURVEYING — -- --- -- 13,�� � 2017 } _- 'J - -� - -- / 0�1i /74 \ _-_____________________ _/_______-__--_-- ___________ Ii --- - - -tel/ T EXIST GRAVEL DRIVEWAY --- ---- /a _ = TO REMAIN 2.10' 'T2.5011E5X8* --- ------ --- ----------`a - —' ;r _r-`r-' �—,�.•� --- �r I ��-- ` I �- I ----- ------ i EXISTING/ WELL Fi-i "J to s :Tax Map_#"1000,=23=01=9:t, ,";;" I I K _- ------���� :� BAND -0-SIDEYARD SETBP _-_ , -: . LINDA"A'::;PIEKARSKI,�y S'.-__'xi, a 1 I I I 4_1 I-_l I I I I II I 1 p W EXIST PROP. I s GARAGE GARAGE I I g \ 6� '\ �f;_ - `_'_,Y"..t"•,=5,�+;-.;`. - nk-.:�z' • 1 I �I i I 1 , \ � O I 1 `' PROP WD DECK \ uJ n', _00,.':�i'�� c'J•r,�='_ _� I ' 1 1 1 � ��Zm � I iia_ , - S1B'12 EXISTING SEPTIC \ HOUSE ,No a o9 1 \ TO REMAIN I PROP WD .' - o H ri,`a' 1 I` I \ \ DECK l i \ I` x�•:' ,<,' .: ` _'_�_, . ,ru.K, \ `I :\ - POOL TE z � I 1 1 � \ I >.- •�y5 •�-t'-„=•�q..o:Cr�apt'a.4;�"`;'!�”, 'f^v�;Go v' ` � � \ \-' , of y ' ro 2.i ` '3•aµ''z�1 .00 ' 1 1 3r`l• ,a> ":u_ ''" :;s: 1 \ \ ADDITION 17z PROP�ND ONG PARENT \ -- _ j RMA ON 10114115 1 I I .r:t. pJ r `'C• -' `-�I�InI'j"5. �.y'��-`.y"'ti��0'WETLA DEC J I •i 1 '' '' 1 '�, : : .- ND RESIdE \ _ _ 4 ; ^#` � ® A K - r I ' C7 I I - J '` :a`CI :F'�:..�,L:`�t ,'�''wk�;o I • ``` �0"(+14-0"AS 1 •- I e-��.r.::. I r �' �-_ • ,, � .'�, a j•'. ` \ \ --t 1- _ L) } _ - I I I , IiI �o� � ,I II' I -r.*,;<:.,�-r^r , ® , - _--,`,,"r;r�.°:a: .,<.='_t."�;.�.u-.•^ - '$.'° I �, ` � \\\ \�\�.�_�1 _oil» — _I O1POL OBSL�TEY' ee;,'POOL DECK FFEXE II 1 Y •f-'{,,''' ,^w-- .��0.�*"`s'^`; �,�;`',�', 1 \ - L-_- ---_ II. °' \ , >�`a:4�':4+-'• PROP �.., :: ..} 'COVEREaaTD 1.11 I m f ev` \ I UTIL. TCY __,S�3.�lGT ACI`Y i7.��3'"A:y•� I , p -e.t., .�l�,.+i,,.Jt>.S, J 'F.p.. - S�Ai b.. `Y:',t.z.E^..^`^,- \ MM-FE Ri=Nt) efiENT OEtQ_ AREA OF WORK 1 ��' ^'� .?.,Y ;jd , _ l�r:J>x ';I `:t '•s .,,:,;A;w`� \ \ uy �` ;,�yt� <r-,''�:• >x' 3- .,j7� .1 / ;, hTA�CE151TISEIv _ S THIS PERMIT 's:_ „k{' i.7t. .,1r;. _'�',i, - :^I• tix', - ii+..s;,- ``" ,z�.• - \ � ,',I„ ,; � m ,-�Sy," - ..,) ,5p WET x. ' _L- \ w!�' N ! ._.=. , UPOQ ,S - - \ \ POOL DRYWEL BACK -IRE ,- \ <':•> - \ W ;..t.. ,' ------------ .' )• PROP L . ERTY -� - r. _ t- rj. - i .1` ElB C - I -0'SIDEYARDS - rJ I - - t11,:g `mss."a'-4 ';x. - �.: `5. '�_>;• � .,• i1�t:e<<'x„ „tt. r tr;,> `r�^ I - -'•a ..� {,`l \• rid: LL 8 6 •,t�� - -:.5� - ...e ;t:aa.,C?6—_ - �_ . --= \ - - _ - _ \ rr7806' . �y`�,,>.r 8Zl�_ „+�i�rs-i; / / 1.-•.5-.' '�• .}'. .f<`5 .�- LlEiti'LTi'• - .- -,\ :R - ,. r ��'+fi ty —- I --- -1-- -�----L .; 500. 1' Map #1000-23-01-6.1 I I I / / :'ib. ^2;"•- ,,_'"-,�`t - - - rd - '•`,ice LAND NOW OR FORMERLY OF ..er,t•` DE LA VEGA & LAWRENCE HIGGINS